Loading...
HomeMy WebLinkAboutAPPROVED WEISE SUPPORTING DOCSF WHY CHOOSE QUALITY STEEL UNDERGROUND TANKS? • 120 - 1,990 WG CAPACITY • General Specifications • Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section VIII, Division 1. • Complies with NFPA 58. • Rated at 250 psig from -20' F to 125' F. All vessels registered with National Board. Two service options available: • Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AGIUG dome • Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with steel AGIUG dome • Family & employee owned • Financing and leasing available • Customized delivery programs available HOW DO I FIND MY SALES REP? Visit our website, www.propanetank.com to view a list of our reps. Once on our site you'll be able to choose the Commercial options and from there you'll be taken to a list of US states where you can choose your location and view the contact information for your local sales rep. If you don't see your sales rep. please give us a call at 800-345-2495. Our manufacturing locations are strategically located to help serve your tank needs. OHIO LOCATION 721 Graham Drive Fremont, OH 43420 UTAH LOCATION 5601 Axel Park Rd. West Jordan, UT 84081 801-280-1133 HOME OFFICE 2914 U.S. 61 Cleveland, MS 38732 800-345-2495 Consult our dimension and specification chart below to find the tank that best fits your needs. Visit our website at www.propanetank.com for more information. OVERALLLENGTH OVI HE LEG SPACING LEG WIDTH Lij \- t LEG WIDTH APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SPECIFICATIONS WATER CAPACITY DIAMETER (OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT LEG* WIDTH LEG** SPACING WEIGHT (Ibs.) **QUANTITY FULL LOAD PER STACK * 120 wg. r 24 Ellip. it 5 -$ r 3 n 1 1 1/2 2'-101/2, or 3 -11 250 108 196 161 12 *250 wg. 30" Hemi. 7'-10" 3'-8" 1'-5" 4'-11" 480 54 9 *320 wg. 30" Hemi. 9'-7" 3'-8" 1'-5" 5' 620 45 9 500 wg. 37 1/2" Hemi. 10, 4'-2" 1'-8" 5' 950 37 30 8 5 1000 wg. 41" Hemi. 16' 4'-5" 1'-8" 1 10'-1" 1,800 17 15 6 5 1450 wg. 46 1/2" Ellip. 17'-4" 4'-11" 1'-9" 11'-7" 2,650 12 4 1990 w . 46 1/2" Ellip. 23'-11" 4'-11" 1'-9" 16' 3,520 8 4 Dimensions and specifications shown are approximate. Individual vessels may vary Leg spacing +/- 2". Leg widths and spacing may vary based on mfg. location. Check with your salesperson for details. 120, 250, 320 wg. standarc tanks - no holes in legs (one center hole on request). 500 and 1000 wg. standard tanks - 2 holes 16" on center. 1450 wg. and up as shown above. ** Full load and stack quantities vary by shipping location. Check with your salesperson for details. QUALITY STEEL Because GuaWfy Steel Means Ouafiry Tanks * ih" Yom fur Suuouslim USA Manulaelurers * HOME OFFICE 2914 U.S.61 Cleveland, MS 38732 800-345-2495 OHIO LOCATION 721 Graham Drive Fremont, OH 43420 419-334-2664 UTAH LOCATION 5601 Axel Park Rd. West Jordan, UT 84081 801-280-1133 Quality Steel 612017 S2 STORAGE TANK IS ADEQUATELY ANCHORED TO PREVENT FLOATATION, COLLAPSE OR LATERAL MOVEMENT DURING THE BASE FLOOD EVENT. ALL WORK SHALL BE IN ACCORDANCE WITH NFPA 54-58, NATIONAL FUEL GAS CODE AND FLORIDA FUEL GAS CODE 2020 & FLORIDA BUILDING CODE 2020. TANKS INSTALLED IN TRAFFIC AREAS SHALL BE PROTECTED WITH GALV. STEEL SCHED. 80 PIPE BOLLARDS (4"0) 6' LONG X 3' BURY DEPTH WITH CAP 0 3' O.C. PROPANE TANK BUOYANCY MAX BUOYANCY = prig*Vwt = 1.94 slug/ft' * 32.2 ft/s! * 66.84 ft' = 4176 LBS NET BUOYANCY = MAX BUOYANCY - WEIGHT OF EMPTY TANK = 4176 LBS - 871 LBS = 3305 LBS FORCE ON N' CABLE = 3305 / 2 = 1653 LBS TENSILE STRENGTH OF J" CABLE = 9800 LBS / 5 = 1960 LE FORCE ON AUGER ANCHOR = 1653 / 2 = 827 LBS MIN. PULL-OUT RESISTANCE OF AUGER ANCHOR = 1360 LBS —11 LP TANK J" 709 GALV. AIRCRAFT CABLE 2 TOTAL (IN POLY. SLEEVE) AUGER ANCHOR, 36' LONG W/ 6.0 HELIX 4 TOTAL SIDE ELEVATION SCALE 1/4" 0 1'-0" Ferrellgas 3232 SE Dixie Hwy. Stuart, FL 34997 Fort Pierce Engineering, Inc. Dependable Mechanical, t;leclrical & Plumbing Design C.A. \o. 29173 315 South 7th Street Fort Pierce, FL. 34950 11one:772 672-4636 Fax 772 E72-4637 GRASS COVER l,R(]I INiI I FUFI `„ ? J.y J.) . I —III —III —III— I 1 j—I � I—III—1 � I —I � I � I -1 f-1II-111-1I1-a 1 - - - - - - 1 (MAX COVER)1 LP TANK EXCAVATION SIZE ' i I 121 x 4'W x 4.5'D 17L8. ANODE BAG " 7x19 GALV. AIRCRAFT CABLE cog' 3 a ae.,oa. a` .0�� eya S4obada,.° P P.E. No,-6pD82: ;ISSIfE"',[WTE - STRAPPING BOLT AUGER ANCHOR 36' 0igitalll signed by Edc Svobnda /�►� HELIX LONG HELI G W/ 6'0 X Date. 2021.111, 1216: 11.52-05'00' Adobe Acrobat version. 2020,013.20074 FRONT ELEVATION SCALE 1/4" — 1'-0" 6R4WN. EJS APPROVEXE",IS DRAWING NUMBER — ']A LP500 NFPA 58-2017 and 2020 Editions Liquefied Petroleum Gas Code TIA Log No.: 1480 Reference: Table l 6.1(n) Comment Closing Date: June 17, 2020 Submitter: Tom Dunn, Iowa Propane Gas Association www.nfoa.org/58 /. Revise Table 16.1(n) to read as follows (highlighted to show corrections): 16. -- IPS Gas. Undiluted Propane Inlet Pressure: i0.0 psig Pressure Drop.1.0 psig �N�...... 1.S2 Gravity. Plastic Pipe S�DR�� 3A, rn. SDR I in. SDR 1i/4 in. SDR 11/2 in. SDR 11 2 in. SDR 11 Length 9.33 1 11 ; 11 11 (1.554) (1.949) (ft) (0.660) (0.86o) (1.007) (1.328) INTENDED USE: Sizing Between First -Stage Pressure Regulator and Second -Stage (Low -Pressure) Rwnilatnr 30 2140 232994290 7740 ..._...,._ 13420 20300 36400 40 1840 3670 6630 11480 17300 31200 50 1630 3260 5870 10180 15400 27500 60 1470 2950 5320 9220 13900 25000 70 1360 2710 4900 8480 — 12800 23000 — 80 1260 2530 4560 7890 11900 21400 90 1180 2370 4270 1 7400 11200 20100 100 1120 2240 4040 6990 10600 19000 123 990 4NW30 3580 6200 9360 16800 150 697 894180i1 826-6-U 3240 5620 5170 8480 7800 15200 175 826 2980 14000 200 778 7481540 2780 4810 7260 13000 225 721 1440 2600 4510 6810 12200 250 681 58.11360 2460 4260 6430 11600 275 646 6461290 2340 4050 6110 11000 300 617 6441240 2230 3860 5830 10470 350 557 56-71L4 0 2050 3550 5360 9640 400 528 548MU 1910 3300 4990 8970 450 495 495 99-2izk 3100 4680 8410 500 468 468931 93716 ' 2930 4420 7950 600 424 424849 849 u-0 2650 4010 7200 700 390 39878A M1410 2440 3690 6620 800 363 363726 340" 7261310 6&4= 2270 3430 6160 5780 900 340 2130 3220 1000 322 32�2fi44 64411 2010 3040 5460 1-50 8 258 544.9.U. 9331620 # r162440 4390 221 2000 22-1442 44329-a 4481380 1343N20 3750 Application Ideal for use as a first stage regulator on any domestic size ASME or DOT container in propane gas installations requiring up to 1,500,000 LISTED BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. • Compact design can be connected to a service valve using either a POL adapter or a RegO product pigtail. • Large threaded W F.NPT bonnet vent can easily be piped -away underground installations without the need of glue kits or extra adapters. • Non Adjustable Large flow orifice resists freeze ups due to water concentration in LPG vapor. • Design provides for good flow regulation at both high and low container pressures. • Built in relief valve and travel stop comply with NFPA 58 over pressure requirements. • Incorporates W RNPT downstream pressure tap for an easy reline check of the regulator's delivery pressure. • Molded diaphragm provides an o-ring type seat between the body and bonnet. • Body and bonnet are assembled in the USA using the unique, patented RegUlok seal system, • Fully painted in brilliant red for complete corrosion protection. • Mounting bracket available as an accessory: part number 2302-31. Materials Body............................................................................................Zinc Bonnet.........................................................................................Zinc Spring........................................................................................ Steel Seat Disc.................................................................Resilient Rubber Diaphragm...........................Integrated Fabric and Synthetic Rubber 6 * i f • W N W 125, 10, 6 7 a W O „ lering Information LV3403TH 9�ILN Z'D.OW ]00JYA I.]SOiOW I.SW.WO I,lS•.W9 FLOW PROPANE LV3403TR Over Outlet LVa403TRV9 %" F./�' F.NPT llss" 10 PSIG 9:00 1,500,000 " Maximum flow based on inlet pressure 20 FISIG higher than the regulator setting and delivery pressure 20%lower than the regulator setting and delivery pressure 2CVo lower than the selling, A14 P-700Q 100 Regp Or Elon, NG 27244 USA wwwregoproducts com >1 (336) 448-7707 Application Designed to reduce first stage pressure of 5 to 20 PSIG down to burner pressure, normally 11" w.c. Ideal for medium commercial installations, vapor meter installations and normal domestic loads. FPaW res • 90 degree right angle inlet to outer connection for meter or standard installations. • Large vent helps to prevent blockage and has $/4' F. NPT for vent piping. • With 15 P&G inlet pressure, regulator is designed to not pass more than 2 PSIG with the seat disc removed. • Replaceable valve orifice and valve seat. • Straight line valve closure reduces wear on seat disc • Unique bonnet vent profile minimizes vent freeze over when properly installed. • Large molded diaphragm is extra sensitive to pressure changes. • Built in pressure tap has plugged W F. NPT outlet. Plug can be removed with a 3/16" hex allen wrench. • Select Brown Finish Rit;lit Angle Design Can mount directly to vapor meter. It is also suitable for mounting directly to the house piping. It will retrofit into existing installations that are currently using a 90 degree, right angle regulator. Body.......................................................................... Die Cast zinc Bonnet........................................................................ Die Cast Zinc NozzleOrifice......................................................................... Brass Spring...................................................................................... Steel Valve Seat Disc ..................................................... Resilient Rubber Diaphragm ......................... Integrated Fabric and Synthetic Rubber UL E 3 10 v�V1 y C �L U C CFH4T.. BI WIIr. w/ Mounting Sradtet M Maximum flow is based or 10 PSIG inlet and 9" wc. delivery pressure. " Mounting Bracket Included. fa �s 100 Rego Dr. Elon, NC 27244 USA www.regoproducts.com +1 (3a6) 449-7707 AMPAD A21