Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 83 LAS CASITAS FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State,Zip: FT.PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Types(1718.3 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block-Int Insul, ExteriorR=4.1 1478.30 ft2 g y p y b. Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c. NIA R= f? 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1306.00 ft2 6. Conditioned floor area above grade(ft') 1306 b. Knee Wail (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade(ft2) 0 c. NIA R= ft2 7. Windows(128.9 sgft.) Description Area 12. Ducts, location &insulation level R ft2 a. U-Factor: Sgl, U=1.02 76.04 ft2 a. a. Sup:Attic, Ret:Attic,AH:Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor: Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtulhr Efficiency c. U-Factor: Sgl, U=1.02 12.85 ftz a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtulhr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor:(AVG) NIA NIA ft2 SHGC(AVG): NIA 15. Hot Water Systems 9. Floor Types Insulation Area 2 a. ElectricTankless Cap: 1 gallons a. Slab-On-Grade Edge Insulation R= 0.0 1306.00 ft2 EF: 0.600 c. NIA R= ft b. Conservation features None 16. Credits None Glass/Floor Area:0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this 'JOE5 Code. calculation indicates compliance with the Florida Energy Code. ?'f . , s PREPARED BY: Before construction is completed this building will be inspected for W. !. DATE: compliance with Section 553.908 Florida Statutes. I hereby certify that this building,as des€gned J ompliance ' with the Florida Energy Codes ��WE OWNE A T: BUILDING OFFICIAL: DATE: \ DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors,tested in accordance with ANSI/RESNETI[CC 380,is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH60(R402.4.1.2). 6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE COTTAGE IMPACT Addresstype: Street Address BuildingType: User Bedrooms: 1 Lot#: -- Owner: WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: --- Total Stories: 1 PlatBook: -- Builder Name: WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY Rotate Angle: 180 County: St Lucie Jurisdiction: Cross Ventilation: No City,State,Zip: FT.PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New(From Plans) Terrain: Suburban Year Construct Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Daitytemp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 13M762001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINK AREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes _6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes 10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # FloorType Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _1 Slab-On-Grade Edge Ins MASTER BEDROOM 31 0 234 It 0.473 - 0.00 1.00 0.00 _2 Slab-On-Grade Edge ins DEN 24 0 144ft 0.473 - 0.00 1.00 0.00 _3 Slab-On-Grade Edge ins SINKAREA 7 0 42ft 0.473 - 0.00 1.00 0.00 _4 Slab-On-Grade Edge Ins CLOSET 1 0 63 ft 0.473 - 0.00 1.00 0.00 _5 Slab-On-Grade Edge Ins GREAT ROOM 32 0 452 ft 0.473 - 0.00 1.00 0.00 _6 Slab-On-Grade Edge Ins MASTER BATH 5 0 50 ft 0.473 - 0.00 1.00 0.00 _7 Slab-On-Grade Edge Ins POWDER 1 0 25ft 0.473 - 0.00 1.00 0.00 _8 Slab-On-Grade Edge Ins KITCHEN 38 0 232 ft 0.473 - 0.00 1.00 0.00 _9 Slab-On-Grade Edge Ins LAUNDRY 1 0 40ft 0.473 - 0.00 1.00 0.00 10 Slab-On-Grade Edge Ins STORAGE 21 0 24 It 0.304 - 0.00 0.00 1.00 6[7/2021 11:47:00 AM EnergyGauge®USA 7.0,00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft2 Oft' Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio(I in) Area RBS IRCC 1 Full attic Vented 150 1306 ft2 N N CEILING (Total Exposed Area = 1336 sq.ft.) # CeilingType Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type _1 UnderAttic(Vented) MASTER BEDROOM 30.0 Blown 234.0ft2 0.053 0.10 Wood _2 UnderAttic(Vented) DEN 30.0 Blown 144.01t 0.053 0.10 Wood _3 UnderAttic(Vented) SINKAREA 30.0 Blown 42.0ft2 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.Oft2 0.053 0.10 Wood _5 UnderAttic(Vented) GREAT ROOM 30.0 Blown 452.0ft2 0.053 0.10 Wood _6 UnderAttic(Vented) MASTER BATH 30.0 Blown 50.0ft2 0.053 0.10 Wood _7 UnderAttie(Vented) POWDER 30.0 Blown 25.0ft2 0.053 0.10 Wood _8 UnderAttic(Vented) KITCHEN 30.0 Blown 232.0f2 0.053 0.10 Wood _9 UnderAttic(Vented) LAUNDRY 30.0 Blown 40.Oft2 0.053 0.10 Wood _10 UnderAttic(Vented) STORAGE 30.0 Blown 24.0ft2 0.030 0.11 Wood _11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.0ft2 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note:First wall orientation below is as entered.Actual orientation is modified by the rotate angle(180 degrees)as shown in the"Project"section on page 1. Adjacent Cavity Width Height Area U- Sheath Fnn. Solar Below J# Ornt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade _1 S=>N Exterior Cone.Bilk Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Cone.Bilk-Int Ins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _3 N=>S Exterior Cone.Bilk-Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=- E Exterior Cone.Bik-Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _5 S=>N Exterior Cone.Bik-Int Ins SINK AREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% _6 N=>S Exterior Cone.Bilk-Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _7 W=>E Exterior Cone.Blk-Int Ins GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% _8 S=>N Exterior Cone.Bilk-Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>S Exterior Cone.Bik-Int Ins KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _10 E=>W Exterior Conc,Bilk Int Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% 11 S=>N Exterior Cone.Bik-Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _12 N=>S Exterior Cone.BIk-Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _13 N=>S Exterior Cone.Bilk-Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _14 N=>S Exterior Cone.Bilk-Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% 15 N= S Garage Frame-Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) Width Height # Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.Oft2 677/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 3 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) Wall --Overhang- ✓# Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation IntedorShade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32Af1= 1.0 ft 5 in 1.0 ft 5 in None None _2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft2 1.0 ft5 in 1.Oft5in None None _3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft' 1.0 ft 5 in 1.0 ft 5 in None None -4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.0' 12.0 ft 0 in 1.0 ft 5 in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 029 N N 6.9ft2 1.0 ft 5 in 1.0 ft 5 in None None 6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8ft' 1.0 ft 5 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse ProposedACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # F1oorArea Roof Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 280 ft' 280 ft' 35 ft 8 ft 11 MASS # Mass Type Area Thickness FumitureFraction Space _1 Default(8lbs/sq.ft.) 0 ft' 0 ft 0.30 MASTER BEDROOM _2 Default(8lbs/sq.ft.) 0 ft' 0 ft 0.30 DEN _3 Default(81bs/sq.ft.) 0 R' 0 ft 0.30 SINK AREA _4 Default(81bs/sq.ft.) 0 ft' 0 It 0.30 CLOSET -5 Default(8lbs/sq.ft.) 0 ft' 0 ft 0.30 GREAT ROOM _6 Defauk(8lbs/sq.ft.) 0 ft' 0 ft 0.30 MASTER BATH _7 Default(81bs/sq.ft.) 0 ft' 0 It 0.30 POWDER -8 Default(8lbs/sq.fL) 0 ft' Oft 0.30 KITCHEN _9 Default(81bs/sq.ft.) Oft' Oft 0.30 LAUNDRY 10 Default(8lbs/sq.fL) 0 ft' Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity -GeothermalHeatPump- Ducts Block kBtu/hr Entry Power Volt Current _1 Electric Heat Pump Split/Single HSPF:8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm 1 Central Unit Split/Single SEER:14.0 29.0 0 0.80 sys#1 1 6/7/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipelns. Pipe length 1 Electric Tankless Garage 0.60(0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR Other Credits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS vDuct Supply - --Return Air CFM 25 CFM 25 HVAC# # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool —1 Attic 6.0120f? Attic 6.0 45fF Default Leakage Attic (Default)(Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans:N Cooling []Jan []Feb []Mar []Apr []May [X]Jun [X]Jul [X]Aug [X]Sep []Oct []NOV []Dec Heating [X]Jan [X]Feb [X]Mar []Apr []May []Jun []Jul []Aug []Sep []Oct [X]Nov [X]Dec Venting []Jan []Feb [X]Mar [X]Apr []May []Jun []Jul []Aug []Sep [X]Oct [X]Nov []Dec JThermostat Schedule: HERS 2006 Reference Hours Schedule7ype 1 2 3 4 5 6 7 8 9 10 11 12 —Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 —Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 —Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) PM 68 68 68 68 68 68 68 68 68 68 68 68 6/7/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 5 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street. THE COTTAGE Permit Office: ST.LUCIE COUNTY City,State,Zip: FT. PIERCE, FL, Permit Number. Y Owner. WYNNE BUILDING CORP. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeableinsulationshall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to uncenditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation forframed walls shall be installed in substantial centactand continuous alignmentwith the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,orcontinuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation,insulation with a Class l vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Narrowcavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessedlighting Recessed lightfixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space she]I extend behind piping and wiring. Showeritub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall onexteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barrier shall be installed behind electrical or onexteriorwalls communication boxes orair-sealed boxes shall be installed. HVAC register boot HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling penetrated by the boot. Concealed When required to be sealed,concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking orother adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 677/2021 11:47:00 AM EnergyGauge®USA 7.0-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index,the more efficient the home. THE COTTAGE,FT. PIERCE,FL, 1. New construction or existing New(From Plans) 10. Wall Types(1718.3 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block-Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame-Wood,Adjacent R=11,0 240.00 ft 3. Number of units, if multiple family 1 c. WA R= ft2 4. Number of Bedrooms 1 d. N/A R= It 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1306.00 If 6. Conditioned floor area above grade(ft2) 1306 b. Knee Wall 2 Conditioned floor area below grade(ft2) 0 c. N/A (Vented) R=19R.0 30.00 ft2 7. Windows" Description Area 12. Ducts, location&insulation level R ft2 a. U-Factor: Sgl,U=1.02 76.04 ft2 a.a.Sup:Attic, Ret:Attic,AH:Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor. Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtu/hr Efficiency c. U-Factor. Sgl, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 It Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor:(AVG) N/A N/A ft2 SHGC(AVG): N/A 15. Hot Water Systems 9. Floor Types Insulation Area a. ElectricTankless Cap: 1 gallons a. Slab-On-Grade Edge Insulation R= 0.0 1306.00 ft22 EF:0.600 b. N/A R= ft b. Conservation features c. N/A R= ft2 None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise,a new EPL Display Card will be completed }3ti S7, based on installed Code compliant features. qY Builder Signature: Address of New Home: "J �t5 �`i"C=cS City/FL Zip:FT.PIIERCE,FL,` -kq-S k 1�.�- 'Note: This is not a BuildingEnergy Rating. If our Index is below 70, our home may wE gy g. y y y qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT. 677/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 of 1 wrightsoft° Project Summary Job: , Entire House BY QUICK CALCS, INC. 317 ST.LUCIE LANE,FORTPIERCE,FL34946 PInre:772-466-6799 Em il:QUICKCALCSQ40LCOM Project Information For: WYNNE BUILDING CORP. THE COTTAGE,FT.PIERCE,FL Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TO 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Structure 15522 Btuh Duds 4013 Btuh Duds 5251 Btuh Central vent(0 chn) 0 Btuh Central vent(0 dm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Bluh Piping 0 Btuh Equipmentload 20340 Btuh Use manufacturer's data In Rate/swing multiplier 0.95 Infiltration Equipment sensible load 19734 Sun Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2094 Btuh Ducts 1524 Btuh Central vent(0 dim) 0 Btuh Heatingg Coolingg (none) Area(ft') 1306 1306 Equipment latent load 3618 Btuh Volume(ff) 10579 10579 Airchanges/hour 0.45 0.23 Equipment Total Load(Sen+Lat) 23352 Btuh EquivAVF(cfm) 79 41 Req.total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO3000GOA0 Cond CH14NBO3000GOA0 AHRI ref 9162387 Coil FX4DNBO43L AHRI ref 9162387 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heating input Sensiblecooling 20300 Btuh Heating output 28000 Btuh @ 47'F Latent cooling 8700 Btuh Temperature rise 26 OF Total cooling 29000 Btuh Actual airflow 967 cfm Actual airflow 967 cfm Airflowfador 0.048 cfrn/Btuh Airflowfador 0.047 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=34 OF Backup: Input=5 kW, Output=18005 Btuh,100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. i`s_ Wry �Q RigF-SOL@Urivers1201919.021RSU08101 2021-Jan1213age 1 AGf+lt Page 1 ...\WrigtSoft FNAQWYNNE BUIOLING-h1E COTTAGE.r,p Calc=M18 Frorl Doortaces:SW wrightsW Right-JO Worksheet Job.' Entire House Date: QUICK CALCS, INC. BY 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phre:772466-6799 Email:QUICKCALCS@AOL.COM 1 Room name Entire House MASTER BEDROOM 2 Eposedwall 145.0 ft 31.0 ft 3 Room height 8.1 ft 8.1 a heatlmol 4 Room dimensions 13.0 x 18.0 ft 5 Roomarea 1306.0 ft" 234.0 ft Ty Construction U-value Or HTM Area Load number (BtuhAF-'F (BWhXt� or penm�r M (BWh) oorperimeter (ft) (BWh) Heat Cool Gross NIPS Heat Cool Gross NAPS Heat Cool 6 Ut/ 13A4as 0.143 n 4.00 2.19 446 427 1710 934 0 0 0 0 �--G 2glaang,droutr, 1.040 n 29.12 21.68 18 0 537 400 0 0 0 0 111 13A4acs 0.143 a 4.00 2.19 162 129 516 282 0 0 0 0 IL-DG 2glaang,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11130 0.390 a 1092 10.34 20 20 223 21 0 0 0 0 W/ 13A4= 0.143 s 4.00 2.19 284 277 1107 605 w 146 584 319 T-G 2glaang,droutr, 1.040 s 29.12 21.68 7 7 202 150 0 0 0 0 vh13A4ors 0.143 w 4.00 2.19 284 192 767 419 105 73 291 159 1Aclom 1270 w 35.56 34.77 41 41 1451 1419 0 0 0 0 10-h1om 1270 w 35.56 61.76 18 3 656 1139 0 0 0 0 1A-hlom 1270 w 35.56 63.40 33 5 1162 2072 33 5 1162 2072 C 16C-30ml 0.032 - 0.90 128 1306 1306 1170 1672 234 234 210 300 F 22A-Ipl 0.989 - 27.69 0.00 1306 145 4015 0 234 31 858 0 6 c)AEDe reon i 3591 997 Envelope lossigain 13985 13393 3105 3847 12 a) Infil4abon 2441 668 522 143 b) RoornwrIlabon 1 0 0 0 0 13 Internal gains O=pants@ 230 2 460 0 0 Appliances/other 1000 0 SubVaI(lines610 13) 16327 15522 X271 3990 Lesseatemal load I 0 0 0 0 Leestran4er 0 0 0 0 Redistibuion 0 0 0 0 14 Subtotal 16327 15522 3627 3990 15 Ductloads 250/. 34% 4013 5251 25% 34% 892 1352 Total room load 20340 20773 Air required(dm) 967 967 4518 5342 215 249 Calculations approved byACCAto meet all requirements of Manual J 8th Ed RigkSuteO 1 p I6 919.021 R3U08101 2021-Jar-121321:40 �'A ...\Wdghtsotl HVAC1WYNNE BUIDLING-THE COTTrAGEAGE.nup CaIc=M Frort Coorfaces:SW Page 1 wrightsW Right-M)Worksheet Jo" Entire House pate: By. QUICK CALCS, INC. 317 ST.LLUE LANE,FORr PIERCE,R-34W Mm:772-466-6799 EmaiI:QUICKGALCS@AOL.COM 1 Room reme DEN SINKARFA 2 F)posedwall 24.0 it 7.0 it 3 Room height &1 ft heallmol 8.1 It heat/cool 4 Room dimensow 12.0 x 12D It 6.0 x 7.0 it 5 Room area 144D ft• 420 IF Ty Conshvution Ll-value Or rea HTM ALoad number (BbhI�-°F) (BWhAN) or perim� (ft) (BWh) orped(mom (ft) (BNh) Heat Co01 Gros NIPS Heat Cool Gros NIPS Heat Cool 6 W 13AA= 0.143 n 400 2-19 97 97 389 213 0 0 0 0 LC 2glaarg,droutr, 1040 n 29.12, 21.68 0 0 0 0 0 0 0 - 0 lQl 13A-4= 0.143 a 400 2.19 0 0 0 0 0 0 0 0 L�DG 2glaang,droutr, 1040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 1034 0 0 0 0 0 0 0 0 W 13AA= 0.143 s 400 2.19 0 0 0 0 57 57 227 124 l--C 2gWrig,droutr, 1040 s 29.12 21.68 0 0 0 0 0 0 0 0 13A-0as 0.143 w 400 2.19 97 79 315 172 0 0 0 0 1Aclorn 1270 w 35M 34.77 0 0 0 0 0 0 0 0 1A-hlorn 1270 w 3556 61.76 18 3 656 1139 0 0 0 0 1A411om 1270 w 35M 63,40 0 0 0 0 0 0 0 0 C- 16C-30ml OA32 - 0.90 - 128 144 144 129 184 42 42 .38 54 F 22A-0 0.969 - 27.69 0.00 144 24 665 0 42 7 194 0 6 c)AED e=rson 574 3 ErNebpe loss/gain 2154 2283 459 175 12 a) Hibralion 404 111 118 32 b) Roomventlation 0 0 0 0 13 Infernalgairm 0—pants@ 230 0 0 0 0 Appliancesbther 0 0 Subtotal(lir=6b 13) 2558 2394 576 207 Lesexbmal load 0 0 0 0 Lestransler 0 0 0 0 Redistribudon 0 0 0 0 14 Subtotal 2558 2394 576 207 15 Ductloads 25% 34% 629 811 25% 34% 142 70 Tool room load 3187 3205 718 278 Airrequired(dm) 152 149 34 13 Calculations aDproved bvACCAto meet all requirements of Manual J 8th Ed. 20214k 121321:40 PogttTHE CD TrAG al20191lc=L RS rortDo �A ...1WrighSORHJAGIWYNNE BUIDLING-THE COTTAGEn.p CaIc=MIB FmrtD00r1a0?S:SW Page 2 t wrightsoflr Right-M Worksheet Job: . Entire House By. QUICK CALM INC. 317 ST.LUCIE LANE,FORT PIERCE,PL34946 Phone-772466-6799 Email:QUICKCALCS@AOLCOM t Room name CLOSET GREAT ROOM 2 E pos:dwall O ft 32.0 it 3 Room height 8.1 ft heatl000l 9.1 ft heaftal 4 Room dimensions 9.0 x 7.0 It 1.0 x 452.0 It 5 Room area 63p 1F 452.0 W Ty Construction U-value Or HTM Area (1) Load Area (ft) Load number (B1uh4 F) (BWW or penmeter (ft) (Btuh) or Parameter (ft) (BWh) r3566 Cool Grass NIPS Heat Cool Gross N/P/S Heat Cool 6 V�/ 13AA= 0.143 n 2.19 0 0 0 0 178 160 640 350 L--C 2 glazing,or outr, 1.040 n 21.68 0 0 0 0 18 0 537 400 W, 13A4as 0.143 a 2.19 0 0 0 0 0 0 0 0 L�--DG 2glaang,droW, 1.040 a 39.42 0 0 0 0 0 0 0 0 71 11DO 0390 a 10.34 0 0 0 0 0 0 0 0 � 1344ocs 0.143 s 2.19 0 0 0 0 0 0 0 0 G 2glaarg,droutr, 1.040 s 21.68 0 0 0 0 0 0 0 0 y! 13AAo s 0.143 w 2.19 0 0 0 0 81 40 161 88 I---G 1A,cl= 1270 w 34.77 0 0 0 0 41 41 1451 1419 IL----GG 1A-hlom 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 1A-h1om 1270 w 35.66 63.40 0 0 0 0 0 0 0 0 C 1601MMI 0A32 - 0.90 128 63 63 Be 81 452 452 405 579 F 22Atpl 0289 - 27.69 0.00 63 0 0 0 452 32 886 0 6 c)AED e=rson -1 2069 Envelopeiosigain 55 80 4080 4903 12 a) Infiltration 0 0 539 148 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Applianoas/other 0 0 Subtotal(lines6to13) 56 80 46191 5511 Lesse malload 0 0 0 0 Lesstrander 0 0 0 0 Redis[buton 0 0 0 0 14 Subtotal 56 80 4619 5511 151 Dud loads 25% 349/6 14 27 25% 34% 1135 1568 Total room load 70 107 5754 7379 Air required(cm) 3 5 274 343 Calculations approved bVACCAto meet all requirements of Manual J M Ed. ti ��w��ti��• 2021Jan-121321:40 Rigl15ueOUriverssi 201919.021 RSU08101 Page 3 ...\Wnglsoft HJAQWVNNEBUIDLING-THECOTTAGE.np Cal.=M18 Fmrt Doortoes:SW wrightsat° RighW@ Worksheet Job: Entire House °fit QUICK CALCS, INC. By. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Pl,one:T2466-6799 Email:OUICKCALCS@,AOL.COM 1 Room name MASTER BATH POWDER 2 E-Aoudwall 5.0 ft 0 ft 3 Room height 8.1 it heaVmol 8.1 it hMVorol 4 Room dimes ons 10.0 x 5.0 ft 5.0 x 5D ft 5 Room area 50.0 IF 25.0 fF Ty Construction U-value Or HIM Area (110 Load Area Load number (Bful d2.9 (B6rhITF) or perimeter (ft) (BWh) or perimeter M (Bwh) Heat Cool Gross NIPrS Heat Cool Gross NIPS Heat Cool 6 V _G 13A-4= 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 2glazing,oroutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 W, 13A4= 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 LL_q_ 2glaang,droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 D 11DO 0.390 a 1092 10.34 0 0 0 0 0 0 0 0 W 134 4= 0.143 s 4.00 2.19 41 34 134 73 0 0 0 0 �G 2glaang,droutr, 1.040 s 29.12 21,68 7 7 202 150 0 0 0 0 13A4o s 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Aciom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 1A-h1om 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1A-h1om 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C30mi 0.032 - 0.90 128 50 50 45 64 25 25 22 32 F 22A-tpl 0.989 - 27.69 0.00 50 5 138 0 25 0 0 0 I 6 c)AEDe racy, 40 Envelope loWgain 520 284 22 32 12 a) Infiltration 84 23 0 0 b) Room ventilation 0 0 0 0 13 Intemalgains: Occupants@ 230 0 0 0 0 Applianoeadther 0 0 Subtotal(lines6to 13) ' 604 307 22 32 Lesextemalload 1 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal I 604 307 22 32 15 Ductloads 25% 34% 148 104 250/6 34% 6 11 Total room load 752 411 Air required(dm) 36 19 28 1 42 2 Calculations approved byACCAto meet all requirements of Manual J 8th Ed -F{i+-wr�9lrrLsaR�.9 A ... R9F 919.021 RSU0810t 2021-Jan-121321:40 \Wdgh6oftHVACWYNNEBUIDLING-THECATTAGE.rLo Calc=M)8 FrortCoorhoes:SW Page 1 wrightsoft° Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Pore:772�66£799 Email:QUICKCALCS@4OL.COM 1 Room name KrTCHEN LAUNDRY 2 Exoaredwall 38.0 It 0 It 3 Room height 8.1 E heatl000l 8.1 It heaVcool 4 Room dimensions 1.0 x 232.0 It 4.0 x 10.0 It 5 Room area 232.0 IF 40.0 1F Ty Construction U-value Or HTM Area (ft) Load Area (ft) Load number (BWhMt F) (Bluhflt) or perimeter (ft) (BWh) or perimeter (ft) (Btuh) Heat j Cool Gross NRIS Heat Cool Gross N/PS Heat Cool 6 W! 13AAM 0.143 n 4.00 2.19 138 138 551 301 0 0 0 0 �--G 2glaang,droutr, 1A40 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-0as 0.143 a 4.00 2.19 130 97 387 211 0 0 0 0 2glaang,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 D 11130 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 13A4= 0.143 s 4.001 2.19 41 41 162 89 0 0 0 0 t-C 2glaarg,drout,, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13AAors 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 to-clom 1270 w 3556 34.77 0 0 0 0 0 0 0 0 IA-hlom 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 1A-h1om 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C-30mI 0.032 - 0.90 128 232 232 208 297 40 40 36 51 F 22A-tp1 0.989 - 27.69 0.00 232 38 1052 0 40 0 0 0 6 c)Am exorrson, -37 -1 Bwelope losygain 2951 157C 36 51 12 a) infiltration 640 175 0 0 b) Roornwrolation 0 0 0 0 13 Irftesrlal gains: Oo:Ipants@ 230 0 0 0 0 Appliance.4other 1000 0 Subtotal(linesft 13) 3591 2745 136 51 LesseMernaliead 0 0 0 0 Less transfer 0 0 0 0 Redistibuton 0 0 0 0 14 Subtotal 3591 2745 36 51 15 Dudloads 25% 34-Al 883 931 25% 34% 9 17 Total mom load 4474 3676 Air required(dm) 213 171 45 68 2 3 Calculations approved byACCAto meet all requirements of Manual J 8th Ed A& -rid-7 w� RigttSUL&Umerml 20l9 l9.021 RSU08101 2021-Jan121 1 ...\Wdghtwft HVAQWYNNESUIDLING-THECOTrAGE.w Caic=W8 Frort Ooorfaces:SW Page 5 wrightsoft- Right-M Worksheet Job; Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772466-6799 Email:QUICKCALCB@P.OL.COM 1 Room name STORAGE 2 Elyos-'ed vall 8.0 ft 3 Room height 8.1 It heaV=l 4 Room dimensone 4.0 x 6.0 ft 5 Room area 24.0 IF Ty Construction U-value Or HTM Area (IF) Load Area Load number (BbrhAF--°F) (BCrh4F) or perimeter (ft) (Bluh) or perimeter Heat Cool Gros N/P/S Heat Cool Gross N/P/S Heat Cool 13AAM 0.143 n 4.00 2.19 32 32 130 71 6 Y—G 2glaarg,droutr, 1A40 n 29.12 21.68 0 0 0 0 13A4ors 0.143 a 4.00 2.19 32 32 130 71 2 glazing,droutr, 1.040 a 29.12 39.42 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 \RI 13AAc s 0.143 $ 4.00 2.19 0 0 0 0 �—G 2glazing,droutr, 1.040 s 29.12 21.68 0 0 0 0 13AAocs 0,143 w 4.00 2.19 0 0 0 0 1Aclom 1270 w 35.56 34.77 0 0 0 0 1A-h1om 1270 w 3556 61.76 0 0 0 0 1A-h1om 1270 w 3556 63.40 0 0 0 0 c 16C-30ml 0.032 - 020 128 24 24 22 31 F 22A-tpl 0.989 - 27.69 0.00 24 8 222 0 6 c)AEDe son _3 Enselopelossigain 502 17C 12 a) InfiMafion 135 37 b) Room venfilafion 0 0 13 Internal gains: Ocwpanfs@ 230 0 0 Applianceslother 0 SubtD6i(lines61013) 637 207 Lesetdemalload 0 0 Lestransfer 0 0 Redistribution 0 0 14 Subtotal 637 207 15J Dudloads 25% 29% 157 60 Total room load 738 212 Airrequired(Cm) Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. RN te CAr 1 RS 2021-Jan-121321:40 ...\WdgttoftHUAC\WYNNEBUIDLIG-THEC07rGE.np Calc=M8 FToniDoorfacesSW Page 6 wrightsoft` Duct System SummaryDale: Entire House sy QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34W Pion:772-46&6799 Em fl:QUICKCALCS@IOL.COM Project • For. WYNNE BUILDING CORP. THE COTTAGE,FT.PIERCE,FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 028 in H2O 028 in H2O Available static pressure 022 in H2O 022 in H2O Supply/return available pressure 0.110/0.110 in H2O 0.110/0.110 in H2O Lowest friction rate 0.080 in/10011: 0.080 in/100ft Actual airflow 967 darn 967 chn Total effective length(TEL) 126 It SupplyDetail Table Design Htg Clg Design Diam H x W Dud Actual Ftg.Egv Name (Btuh) 0m) (cim) FR pn) (in) Mail Ln(it) Ln(ft) Trunk CLOSET c 107 3 5 0.080 4.0 OxO VIFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 OxO VIFx 33.5 90.0 st1 GREAT ROOM c 3689 137 172 0.080 8.0 0x0 VIFx 14.6 70.0 GREAT ROOMA C 3689 137 172 0.080 8.0 OxO VIFx 16.1 70.0 KnU-rN h 4474 213 171 0.080 7.0 OxO VIFx 4.5 70.0 LAUNDRY c 68 2 3 0.080 4.0 Ox0 VIFx 5A 70.0 MASTERBATH h 752 36 19 0.080 4.0 OxO VIFx 32.9 90.0 st1 MASTERSEDROOM c 2671 107 124 0.080 7.0 Ox0 VIFx 27.9 90.0 st1 MASTERBEIXROOM-A c 2671 107 124 0.080 7.0 0x0 VIFx 35.9 90.0 SH POWDER c 42 1 2 0.080 4.0 Ox0 VIFx 292 90.0 st1 SINK AREA h 718 34 13 0.080 4.0 0x0 VIFx 30.9 90.0 st1 STORAGE h 794 1 38 12 0.080 4.0 OxO VIFx 112 70.0 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (crm) FR (fpm) (in) pn) Material Trunk st1 PeakAVF 441 437 1 0.080 561 12.0 0 x 0 VinlFix wrightsoft- 2021Ja 121321:41 �(\ ,.v-, �.�.,�,,,., Rgtd-Suta@L4iwml201919.021RSU08101 Pages ...1WrigttMftWACIWYNNEBUIDLING-h1ECOTTAGEnp CaIc=MS FrortDoorfa SW Return Branch Detail Table Grille mg Gg TEL Design Ueloc Diam H x W Stud/Joist Duct Name Size(n) (cfm) (dm) (it) FR (fpm) (in) (in) Opening(n) Mat Trunk rb1 NO 1 967 967 0 0 0 0 Ox 0 MR Wrightsoftm 20214k 121821:41 MgttSukeS Udv 1201919.021 RSU08101 Page 2 ...\WngMsoR HVAgWVNNE BUIULING-7HE CATTAGEnp Cak=MIB Flort Ooorf�-SW