Loading...
HomeMy WebLinkAboutAPPROVED ENERGY CALCS & MANUAL J - 6 OCTAVIO FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State,Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Types(1718.3 sgft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block-Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame-Wood,Adjacent R=11.0 240.00 ft2 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sgft.) Insulation Area a. Under Attic(Vented) R=30,0 1306.00 ft2 6. Conditioned floor area above grade(W) 1306 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade(ft2) 0 c. NIA R= ft2 7. Windows(128.9 sgft.) Description Area 12. Ducts, location &insulation level R ft2 a. U-Factor: Sgl, U=1.02 76.04 ft2 a. a. Sup:Attic, Rat:Attic, AH:Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor: Sgl, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtulhr Efficiency c. U-Factor: Sgl, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency 8_ Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor:(AVG) NIA NIA ft2 SHGC(AVG): NIA 15. Hot Water Systems 9. Floor Types Insulation Area a. ElectricTankless Cap: 1 gallons a. Slab-On-Grade Edge Insulation R= 0.0 1306.00 f? EF:0.600 b. NIA R= ft b. Conservation features c. NIA R= ft2 None 16. Credits None Glass/Floor Area:0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this , Code. calculation indicates compliance with the Florida Energy Code. to �6 lhlle,. ''�r, ,,,fi t _ ,- PREPARED BY: Before construction is completed a �' this building will be inspected for f_ DATE: 6--7-2021 compliance with Section 553.908 Florida Statutes. I hereby certify that this building, as desigaged vmpliance with the Florida Energy Codg,- - O� OWN A Iy - BUILDING OFFICIAL: DATE: �\ DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage Qn requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors,tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.000 Qn for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2). 617/2021 11:47:00 AM EnergyGauge@)USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUILLING-THE COTTAGE IMPACT Address type: Street Address Building Type: User Bedrooms: 1 Lot#: - Owner. WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision:Total Stories: 1 PlatBook: - BuilderName: WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY Rotate Angle: 180 County: St.Lucie Jurisdiction: CrossVenfilation: No City,State,Zip: FT.PIERCE, Family Type: Detached Whole House Fan: No FL, New/Existing: New(From Plans) Terrain: Suburban Year Construct: Shielding: Suburban Comment: CLIMATE Design Design Temp Im Design Temp Heating Design Dailytemp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range _FL,Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 139576.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINK AREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes _6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes 10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _1 Slab-On-Grade Edge Ins MASTER BEDROOM 31 0 234 ft 0.473 - 0.00 1.00 0.00 _2 Slab-On-Grade Edge Ins DEN 24 0 144It 0.473 - 0.00 1.00 0.00 _3 Slab-On-Grade Edge Ins SINKAREA 7 0 42ft 0.473 - 0.00 1.00 0.00 _4 Slab-On-Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.00 _5 Slab-On-Grade Edge Ins GREAT ROOM 32 0 452 It OA73 - 0.00 1.00 0.00 _6 Slab-On-Grade Edge Ins MASTER BATH 5 0 50ft OA73 - 0.00 1.00 0.00 _7 Slab-On-Grade Edge Ins POWDER - 1 0 25 It 0.473 - 0.00 1.00 0.00 _8 Slab-On-Grade Edge Ins KITCHEN 38 0 232It 0.473 - 0.00 1.00 0.00 _9 Slab-On-Grade Edge Ins LAUNDRY 1 0 40ft 0.473 - 0.00 1.00 0.00 10 Slab-On-Grade Edge Ins STORAGE 21 0 24 ft 0.304 - 0.00 0.00 1.00 677/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft2 Oft' Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1306 ft2 N N CEILING (Total Exposed Area = 1336 sq.ft.) # CeilingType Space R-Value Ins.Type Area U-Factor Framing Free. Truss Type _1 UnderAtfic(Vented) MASTER BEDROOM 30.0 Blown 234.Oft2 0.053 0.10 Wood _2 UnderAtfio(Vented) DEN 30.0 Blown 144.oft2 0.053 0.10 Wood _3 UnderAtfic(Vented) SINK AREA 30.0 Blown 42.Oft2 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.Of 0.053 0.10 Wood _5 UnderAttic(Vented) GREAT ROOM 30.0 Blown 452.0112 0.053 0.10 Wood _6 UnderAttic(Vented) MASTER BATH 30.0 Blown 50.0ft 0.053 0.10 Wood _7 UnderAttic(Vented) POWDER 30.0 Blown 25.Of 0.053 0.10 Wood _8 UnderAttic(Vented) KITCHEN 30.0 Blown 232.0ft 0.053 0.10 Wood _9 UnderAtfic(Vented) LAUNDRY 30.0 Blown 40.Oft2 0.053 0.10 Wood _10 UnderAttic(Vented) STORAGE 30.0 Blown 24.Oft 0.030 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.0ft2 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note:First wall orientation below is as entered.Actual orientation is modified by the rotate angle(180 degrees)as shown in the"Project"section on page 1. Adjacent Cavity Width Height Area U- Sheath Frm. Solar Below V# Omt To Wall Type Space R-Value Ft In Ft In sq.ft. Factor R-Value Free. Absor. Grade _1 S=>N Exterior Cone.Bik-Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Cone.Blk-Int Ins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% _3 N=>S Exterior Cone.Bik-Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Cone.Bik-Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _5 S=>N Exterior Cone.Bik-Int Ins SINK AREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% _6 N=>S Exterior Cone.Blk-Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _7 W=>E Exterior Cone.Blk-Int Ins GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 - 0% _8 S=>N Exterior Cone.BIk-Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>S Exterior Cone.Blk-Int Ins KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% 10 E=>W Exterior Cone.Blk-Int Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _11 S=>N Exterior Cone.BIk-Int Ins KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _12 N=>S Exterior Cone.BIk-Int Ins KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% 13 N=>S Exterior Cone.Blk-Int ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _14 N=>S Exterior Cone.Blk-Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% 15 N=>$ Garage Frame-Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area =20 sq.ft.) Width Height J# Ornt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.Oft2 6/7/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edifion(2020)Compliant Software Page 3 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) Wall ---Overhang-- J# Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation Interior Shade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.41P 1.0 it 5 in 1.0 it 5 in None None _2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.02 1.0 ft 5 in 1.0 ft 5 in None None _3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft2 1.0 it 5 in 1.0 ft 5 in None None -4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.Oft2 12.0 R 0 in 1.0 ft 5 in None None -5 S=>N 8 Metal Low-E Single Yes 1.02 0.29 N N 6.9ft- 1.0 ft 5 in 1.0 it 5 in None None 6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8ft- 1.0 it 5 in 1.0 it 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse ProposedACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 280 fl 280 ft2 35 it 8 it 11 MASS # Mass Type Area Thickness FumitureFraction Space _1 Default(8lbs/sq.ft.) 0 ft2 0 it 0.30 MASTER BEDROOM _2 Default(8lbs/stift) 0 ft2 0 it 0.30 DEN _3 Default(8lbs/sq.ft.) 0fl2 Oft 0.30 SINK AREA _4 Defaulg8lbs/sq.fL) 0 ft2 0 ft 0.30 CLOSET -5 Default(81bs/sq.fL) 0 ft2 0 it 0.30 GREAT ROOM _6 Default(81bs/sq.tL) 0 ft2 0 it 0.30 MASTER BATH _7 Default(Slbs/sq.ft.) Oit- 0 it 0.30 POWDER -8 Default(8 lbs/sq.ft.) 0 ft2 0 it 0.30 KITCHEN _9 Default(8lbstsq.fL) 0ft2 Oft 0.30 LAUNDRY 10 Default(8lbs/sq.ft.) 0 ft2 Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity -GeothermalHeatPump- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump SpIiUSingle HSPF:8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity Air Flow SHR Duct Block kBtu/hr ofm 1 Central Unit Split/Single SEER:14.0 29.0 0 0.80 sys#1 1 677/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 4 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPrlt Fixture Flow Pipe Ins. Pipelength 1 Electric Tankless Garage 0.60(0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Rears Control Loop Branch Pump DWHR Facilities Equal DWHR OtherCredits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS JDuct —supply— ---Retum----- Air CFM 25 CFM 25 HVAC# # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6.0 120 ft' Attic 6.0 45 ft= Default Leakage Attic (Default)(Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans:N Cooling []Jan []Feb []Mar []Apr [I May [X]Jun [X]Jul [X]Aug [X]Sep []Oct []Nov []Dec Heating [X]Jan [X]Feb [7Q Mar []Apr []May [I Jun []Jul []Aug []Sep []Oct [X]Nov [X]Dec Venting []Jan []Feb [X]Mar [X]Apr [j May []Jun []Jul []Aug []Sep [X]Oct [X]Nov []Dec VThermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 _Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6[7/2021 11:47:00 AM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 5 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIAa Project Name: WYNNE BUIDDING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CORP. Jurisdiction: O Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-pemleableinsulationshall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air bartier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and anddoors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floorframing cavity insulation shall be installed to (including insulation. maintain permanent contactwith the underside of above-garage subfloor decking,orfloorframing cavity insulation andcantilevered shall be permitted to be in contact with the top side floors) ofsheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawlspacewalls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation,insulation with a Class l vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessedlighting Recessed light fixtures installed in the building thermal Recessed light fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforinsto available space shall extend behind piping and wiring. Shower/tub The airbarrier installed at exterior walls adjacent to showers Exteriorwalls adjacent to showers and tubs shall onexteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barrier shall be installed behind electrical or onexteriorwalls communication boxes or air-sealed boxes shall be installed. HVAC register boot HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or ceiling penetrated by the boot. Concealed When required to be sealed,concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 6/7/2021 11:47:00 AM EnergyGauge®USA 7.0-FlaRes2020 FBC 7th Edition(2020)Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index,the more efficient the home. THE COTTAGE,FT. PIERCE,FL, 1. New construction or existing New(From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block-Int Insul, ExtedorR=4.1 1478.30 fe b. Frame-Wood,Adjacent R=11.0 240.00 ft 3. Number of units, if multiple family 1 c. WA R= fe 4. Number of Bedrooms 1 d.N/A R= ftZ 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic(Vented) R=30.0 1306.00 ftZ 6. Conditioned floor area above grade(ft') 1306 b.Knee Wall(Vented) R=19.0 30.00 ft2 Conditioned floor area below grade(ft') 0 c. N/A R= ft2 7. Windows** Description Area 12. Ducts, location&insulation level R fe a. U-Factor: Sgl,U=1.02 75.04 fe a.a.Sup:Attic, Ret:Attic,AH:Attic 6 120 SHGC: SHGC=0.29 b. b. U-Factor. Sgl, U=1.03 40.00 ftZ C. SHGC: SHGC=0.27 13. Cooling Systems kBtu/hr Efficiency c. U-Factor. Sgl, U=1.02 12.85 ft2 a.Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtu/hr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor.(AVG) WA N/A ft2 SHGC(AVG): N/A 15. Hot Water Systems 9. Floor Types Insulation Area z a. EledricTankless Cap: 1 gallons a. Slab-On-Grade Edge Insulation R= 0.0 1306.00 ft EF:0.600 b. N/A R= fe b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed g%ESx based on installed Code compliant features. Of Builder Signature: Date: CA-c" � Address of New Home: C \ `-w-, V City/FL Zip: FT. PIERCE,FL, rya 5l *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for G'An WE energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. -Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6[7/2021 11:47:00 AM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020)Compliant Software Page 1 of 1 Project Summary Job: vurightsoft® Entire House ay QUICK CALCS, INC. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phone:772-466-6799 Email:QUICKCALCS A0LCOM Proiect Information For. WYNNE BUILDING CORP. THE COTTAGE,FT.PIERCE,FL Notes: Design Information Weather: Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Btuh Structure 15522 Btuh Ducts 4013 Btuh Duds 5251 Btuh Central vent(0 cirri) 0 Btuh Central vent(0 cim) 0 Btuh (gone) 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 20340 Btuh Use manufacturers data n Rate/swingg multiplier 0.95 Infiltration Equipmeni sensible load 19734 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2094 Btuh Duds 1524 Btuh Central vent(0 cfm) 0 Btuh Heating Cool, (none) Area(tta) 1306 1306 Equipment latent load 3618 Btuh Volume(f 3) 10579 10579 Airchanges/hour OA5 0.23 Equipment Total Load(Sen+Lat) 23352 Btuh Equiv.AVF(dm) 79 41 Req.total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO3000GOA0 Cond CH14NBO3000GOA0 AHRI ref 9162387 Coil FX40NB043L Efficiency 8.2 HSPF Efficiency RI ref 9162387 11.5 EER,14 SEER Heating input Sensible cooling 20300 Btuh Heating output 28000 Btuh @47-F Latent cooling 8700 Btuh Temperature rise 26 OF Total cooling 29000 Btuh Actual air low 967 cfm Actual airflow 967 cfm Air flow factor 0.048 dm/Btuh Airflowfador 0.047 cfin/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=34 OF Backup: Input=5 kW, Output=18005 Btuh,100AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. .G wr Q�YSQ AQC�l .. 2021-Jan121 RigkSute®Uriwrsa1201919.021 RSU08101 Page I -THECOTTAGE.up Caic=MI8 FrortDoorfzrnsSW.Wngh 6oftHUACWYNNEBUIDLING wrightsoW RighW@ Worksheet Job: Entire House per QUICK CALCS, INC. By. 317 ST.LUCIE LANE,FOR"PIERCE,R34946 PFnre:T2466-5799 Emad:QUICKCALCS@AOL.COM 1 Room rame Erlfire House MASTER BEDROOM 2 Exposedwall 145D ft 31.0 ft 3 Room height 8.1 2 8.1 ft heaftol 4 Room dimensions 13D x 18D It 5 Roomarea 13060 fF 234D fF Ty Construrdon U-%alue Or HTM Area (ft?) Load Area Load number (Bk KIF-9 (BWh" or perimeter (BWh) or perimeter (it) (BWh) Heat Cool Gras NIPS Heat Cool Gros NAPS Heat Cool 6 1p/ 13A4= 0.143 In 4.00 219 446 427 1710 934 0 0 _ 0 0 �C 2glaarg,droutr, tA40 n 29.12 21.68 18 0 537 400 0 0 0 0 W 13A4as 0.143 e - 4A0 219 162 129 516 282 0 0 0 0 II-- 2glaangdroutr, 1D40 a 29.12 39A2 13 2 368 498 0 0 0 0 11 11DO 0.3W a 10.92 10.34 20 20 223 211 0 0 0 0 Vy 13AAM 0.143 s 4.00 2-19 284 277 1107 605 146 146 564 319 �--C 2glaarg,droutr, 1D40 s 29.12 21BB 7 7 202 150 0 0 0 0 13AA= 0.143 w 4.00 219 284 192 767 419 105 73 291 159 1Aotpn 1270 w 35.56 34.77 41 41 1451 1419 0 0 0 0 1A.hlom 1270 w 3556 61.76 18 3 656 1139 0 0 0 0 lA-hlom 1270 w 35,56 63.40 33 5 1162 2072 33 5 1162 2072 C- 16C-30mi 01M - 0.90 128 1306 1306 1170 1672 234 234 210 300 F 22A-tpi 0.989 - 27B) 0D0 1306 145 4015 0 234 31 858 0 6 c)Ame=rsion 3591 997 Envelope loss(gain 13885 13393 3105 3847 12 a) hfilbalim 2441 668 Sn 143 b) Room eenfilafion 0 0 0 0 13 Intemalgains Omlpants@ 230 2 460 0 0 AppliancsbIter low 0 Subbtal(lires6013) 16327 15522 3627 3990 Lesexbmal load 0 0 0 0 Lestansfer 0 0i 0 0 Redisbibulim 0 0 0 0 14 Subtotal 16327 15522 3627 3990 15 Dud loads 25% 340% 4013 5251 25% 34% 892 1352 Total room load 2IX3 20773 41 54 Airrequired(dm) 96767 967 215 249 Calculations approved byACCA to meet all requirements of Manual J 8th Ed c 2021Ja 121321N0 Ri9-THE OTTA E.np 919.021 B Fror Do Page 1 _.1WrigF�oftHVACiWYNNE BUIDLING-"fFIE COTTAGE.np Cale=M18 FraiDoortares SW t'wrightsofr flight-JO Worksheet Job: Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LANE,FORTMERCE,FL34946 Phone:772-466-6799 Email:QUICKC4LCS@gOL.00M 1 Room name DEN S14KAREA 2 Eposedwall 24.0 it 7.0 it 3 Room height 8.1 ft heaV=l 8.1 ft heatbod 4 Room dimensions 12.0 x 12D It 6.0 x 7D H 5 Roomalea 144.0 ft' 420 T Ty gcnslru prl Uaelue Or HTM Ales (T) Load Area (r Load number (BtuhNp-*n (Bumn ar pedmeber (1L) Ptuh) or perimeter (ft) (BWh) Heat Cool Gras NIPS Heat Cool Gras NIPS Heat Cool 6 yy IMAM 0.143 n 4.00 2.19 97 97 389 213 0 0 0 0 -L—C 2glaarg,droutr, 1D40 n 29.12 21.68 0 0 0 0 0 0 0 0 W 13A-4= 0.143 a 4A0 219 0 0 0 0 0 0 0 0 II--DG 2gkarg,droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11D0 0" a 10,92 10.34 0 0 0 0 0 0 0 0 W 13kAos 0.143 s 4D0 2.19 0 0 0 0 57 57 227 124 L—C 21aarg,droutr, 1.040 s 29.12 21RS 0 0 0 0 0 0 0 0 y/ 13A-4= 0.143 w 4m 219 97 79 315 172 0 0 0 0 III--GGG tA,olw 1270 w 35M 34.77 0 0 0 0 0 0 0 0 l"lom 1270 w 3556 61.76 18 3 656 1139 0 0 0 0 1A-hlom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C- 16C-30m1 OD32 0.90 128 144 144 129 184 42 42 .38 54 F 22A40 0M - 27.69 0.00 144 24 665 0 42 7 194 0 6 c)AED exaxsicn 574 3 Emelopelossigain 2154 2283 459 175 12 a) hflhr lon 404 111 118 32 b) Rcom%wMialion 0 0 0 0 13 Inpmalgains: Ooarpan5@ 230 0 0 0 0 P.ppliannesblher 0 0 SubHrtal(Imes64r 13) 2558 2394 576 207 Lessexemalload 0 0 0 0 Lesstrans'er 0 0 0 0 RedLWbution 0 0 0 0 14 Subtotal 2558 2394 576 207 15 Dudloads 25% 34% 629 811 25% 34% 142 70 Total room load 3187 3205 718 278 Airrequired(dm) 1 152 149 34 13 Calculations approved WACCAto meet all requirements of Manual J 8th Ed. -rw w i+� 2021-Ja 121321:40 A&K RgHSute@Wwrsa1201919.021 RSt108101 Paget ...1WdgMAWAQWYNNEBUIDLING-THECOTrAGE.np Calc=MB lioADDorfanes:SW -►-wrightsoft• Right-M Worksheet Jcb: Entire House Date: QUICK CALM INC. By. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Ptona:772+4666799 EmaII:QUICKCALCS@AOL.00M 1 Room name CLOSET GREAT ROOM 2 Bposed Hall 0 ft 32.0 It 3 Room height 8.1 ft heatlmcl 8.1 ft heatlmoi 4 Room dimensions 9.0 x 7.0 It 1.0 x 452.0 ft 5 Room area 63.0 1F 452.0 fF Ty Construction U-value Or HTM Area (fF) Load number (BIuhd--°F) (Bbuw) or perimeter (ft) (Ruh) or perimeter (ft) (Btuh) Heat Cool Gras NtP/S Heat Cool Gross NPS Heat Cool 6 W 13AAors 0.143 n 4A0 2.19 0 0 0 0 178 160 640 350 �—G 2glaarg,droutr, ID40 n 29.12 21.68 0 0 0 0 18 0 537 400 V�J 13A4o s 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 IL--(D- 2glaang,droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11DO 0.390 a 1(92 10,34 0 0 0 0 0 0 0 0 13AAoce 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 G 2glazing,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13AAocs 0.143 w 4.00 219 0 0 0 0 81 40 161 88 1Actom 1270 w 3556 34.77 0 0 0 0 41 41 1451 1419 1A.hlom 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1A-hlom 1270 w 35S6 63.40 0 0 0 0 0 0 0 0 C 16cam1 0.032 - 0.90 128 63 63 56 81 452 452 405 579 f 22A-tpl 0.989 - 27.69 0.00 63 0 0 0 452 32 886 0 6 c)AED emurson -1 2069 Erwelope lossgain 56 80 4080 4903 12 a) Infiltration 0 0 539 148 b) Roomventilabon 0 0 0 0 13 Internal gains O¢vpants@ 230 0 0 2 460 Appliari=dcther 0 0 Sub=](line;6 In 13) 56 80 4619 5511 Lese#emalload 0 0 0 0 Lesstansfer 0 0 0 0 Redistibulion 0 0 0 0 141 Subtotal 56 80 4619 5511 15 Ductloads 259/6 34% 14 27 25% 34% 1135 1868 Total room load I 79 Air required(dm) 73 105 274 733433 t� Calculations approved bvACCA to meet all requirements of Manual J 8th Ed c YF w��9lsYSWt^... RigtH a1201919.021 RSU08101 : 2021Jan-121321:40 \WrgF�oftFNAG\WYNNEBUIDLING-TECOTTAGE.np Calc=M18 FmdDoorfacesSW Page 1 wrightsoft° Right-J®Worksheet Job Entire House Data: QUICK CALCS, INC. BY 317ST.LLUE LANE,FORTPIERCE,FL34946 Plmm:772466-6799 Emil:QI11GKCALCS@AOL.00M 1 Roomname MASTER BATH POWDER 2 EVosdwall 5.0 ft 0 It 3 Room height 8.1 it heaNmol 8.1 It heallmol 4 Room cimensi re 10D x 5.0 ft 5D x 5.0 It 5 Room area SOD iF 25.0 T Ty construction U-value Or HTM Area Load Load number (BWVF-F) (BWhffn or perimeter (ft) (BWh) a�pedme� (ft) (Bpih) Heat Cool Gros NIPS Heat Cod Gros NPS Heat cod 6 W 13A-4= 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 �f' 2gla�g,droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A4o s 0.143 a 4.00 2.19 0 0 0 0 0 0 0 - 0 2gglaang,droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11D0 0390 a 10.92 10.34 0 0 0 0 0 0 0 0 Vr/ 13A-4ocs 0.143 s 4.00 2.19 41 34 134 73 0 0 0 0 ---C 2glaorg,droutr, 1D40 S 29.12 21BB 7 7 202 150 0 0 0 0 Vy 1A,c1w 1270 w 4D0 4.77 0 0 0 0 0 0 0 0 ILA—EGG 1Actam 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 IA-hlam 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1A-h1= 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 1SC30ml 0.032 - 0.90 120 50 50 45 64 25 25 22 32. F 22A4p] 0.989 - 27B9 ODO 50 5 138 0 25 0 0 0 6 c)AEDemlrsim 4 0 Ernelope losAgain 520 284 22 32 12 a) Infiltration 84 23 0 0 b) Roomvenfilafion 0 0 0 0 13 Infernal gains O=pamc 230 0 0 0 0 Applianwsbther 0 0 Subtltal(lines(Bt113) 604 3071 1221 32 Lesademalload 0 0 0 0 Lestansfer 0 0 0 0 Redishibufion 0 0 0 0 14 Subtotal 604 307 22 32 15 Dud loads 25% 34% 148 104 25% 34% 6 11 Total mom load 752 411 - 28 42 Air required(dm) 36 19 1 2 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. rtk- 2021J 12132140 A&k F49F[Sufe®lhi�ersar 20t919.021 RS110810t Page 4 ...\WrigFZoft HJAgWY NEBUIOLING-THECOTrAGE� Calc=NUS Frort Oaorfar :SW -#wrightsoft' Right-M)Worksheet Job: Entire House Dom: QUICK CALCS, INC. BY 317 ST.LUCIE LANE,FORTPIERCE,FL34946 Phure:772-4665/99 Em d:QUICKCALCS@AOL.COM 1 Room name KITCHEN LAUNDRY 2 EVosedwall 3&0 it 0 It 3 Room height &1 ft heall=l 8.1 ft heatlmol 4 Room dimensions 1A x 2320 ft 4.0 x 10.0 it 5 Roomarea 232.0 1F 40A T Ty I Corebudon U-wilue Or HTM Area (IF) Load number (BWhtF-*n (BWhiM or perimeter (it) (BWh) orperimeter (ft) OWN Heel Cool G. NIPS Heat Cool Gros NIPS Heat Cool 6 rRl 13AA= 0.143 n 4.00 2.19 138 138 551 301 0 0 0 0 �G 2glaarg,droub, 1.040 n 29.12 21M 0 0 0 0 0 0 0 0 4y 13A-4= 0.143 a 4D0 2.19 130 97 387 211 0 0 0 0 II--- 2glaang,dreub, 1A40 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11DO 0" a 10.92 10.34 20 20 223 211 0 0 0 0 W 13A-4= 0.143 s 4A0 2.19 41 41 162 89 0 0 0 0 L—G 2g1alg,droub, 1ID40 S 29.12 21M 0 0 0 0 0 0 0- 0 13AAM 0.143 w 4.00 219 0 0 0 0 0 0 0 0 1Aclw 12M w 35M 34.77 0 0 0 0 0 0 0 0 1A411om 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1A-hlw 1270 w 35M 63.40 0 0 0 0 0 0 0 0 C- 16C-30ml 0.032 - 090 128 232 232 208 297 40 40 36 51- F 22A-tpI 09M - 27.69 0z 232 38 1052 0 40 0 0 0 6 c)AED e=rsim S7 -1 Ernelope loss/gain 2951 1570 36 51 12 a) liftallm 640 175 0 0 b) Roamveri lades 0 0 0 0 13 htemal gains. O=pants@ 230 0 0 0 0 Appliancesb1her 1000 0 Subblfaloines6W13) 3591 2745 36 51 1-molarralload 0 0 0 0 Lmtransfer 0 0 0 0 Redistibulion 0 0 0 0 14 Subtotal 3591 2745 36 51 15 Ductloads 25% 349/6 BM 931 25% 34% 9 17 ToW room load 4474 3676 45 68 Airrequired(dm) 213 171 2 3 Calculations approved bvACCAto meet all requirements of Manual J ft Ed. 202W- 121321:40 �ZcA RigltShce6Urive l 201919.021 RSU08101 Pages ...\WdgY ftHUAC\WY NEBUIDLING-THECOTTAGE.r Cal,IvUS Fmrt Doorfaces SW F�wrightsofC RighW@ Worksheet Job: Entire House Dfit QUICK CALCS, INC. By. 317 ST.LUCIE LANE,FORT PIERCE,FL34946 Phore:772466-6799 Email:QUICKCALCS@AOL.COM 1 Room name STORAGE 2 EVosedvall 8.0 ft 3 Room height 8.1 it heaVoxl 4 Room dimensons 4.0 x 6.0 ft 5 Room area 24.0 ff Ty Construction U-value Or HTM Area Load Area Load number (BWh/fIMF) (BWh4t') or perimeter (ft) (Btuh) or perimeter Heat Cool Gras NIPS Heat Cool Gross NIPS Heat Cool 6 VN 13A-4ocs 0.143 n 4A0 2.19 32 32 130 71 �G 2glazing,droutr, 1.040 n 29.12 21.68 0 0 0 0 13A4ocs 0.143 e 4.00 2.19 32 32 130 71 2 glazing,orcutr, 1.040 a 29.12 39.42 0 0 0 0 11 D 11D0 0290 a 1092 10.34 0 0 0 0 Vy 13A4= 0.143 5 4.00 2.19 0 0 0 0 �a 2glazing,droutr, 1.040 s 29.12 21.68 0 0 0 0 13A4cc5 0.143 w 4.00 2.19 0 0 0 0 1Actam 1270 w 35.56 34.77 0 0 0 0 lA-hlom 1270 w 35.56 61.76 0 0 0 0 1A-hlom 1270 w 35M 63.40 0 0 0 0 C 16C30ml 0.032 - 0.90 128 24 24 22 31 F 22A-tpl 0.989 - 2T69 0.00 24 8 222 0 i 6 c)AID exnnsion -3 EmelopelosNgain 502 170 12 a) Infiltafion 135 37 b) Room aenfilation 0 0 13 Intemalgaim Ooalpanls@ 230 0 0 Applianoedother 0 Subtotal(lines6to13) 637 207 Lesexemzlload 0 0 Lesstrartder 0 0 Redistribution 0 0 14 Subtotal 637 207 151 Duct loads 25% 29% 157 60 Total room load 794 266 Airrequired(dm) 38 12 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed -FFF wN9r+>CsoTe� 2021-JarN21321:40 fING-T ECOTAGE. p Calc.021RSU06107 Page ...\WdgFlsoft HVAgWYNNE BUIDLING-THE COTTAGE.rup CaIc=MJB FrortDoorfaces:SW - 1- wrightsofta Duct System Summary o : Entire House By. QUICK CALCS. INC. 317 ST LUCELANE,FORTPIERCE,FL34946 PIDra:772-466-6799 Ereil:QUICKCALCS@AOLCDM Project • For. WYNNE BUILDING CORP. THE COTTAGE,FT.PIERCE,FL Heating Cooling Extemal static pressure 0.50 in H2O 0.50 in H2O Pressure losses 028 in H2O 028 in F120 Available static pressure 0.22 in H2O 022 in H2O Supply/return available pressure 0.110/0.110 in H2O 0.110/0.110 in H2O Lowestfrfction rate 0.080 in/100ft 0.080 in/10011 Actual airflow 967 dim 967 din Total efrective length(TEL) 126 ft SupplyDetail Table Design Htg Clg Design Dam H x W Dud Actual Ftg.Egv Name (Btuh) (din) (dm) FIR (in) (in) Mail Ln(ft) Ln(ft) Trunk CLOSET c 107 3 5 0.080 4.0 OxO VIFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 OxO VIFx 33.5 90.0 st1 GREATROOM c 3689 137 172 0.080 8.0 0x0 VIFx 14.6 70.0 SAT ROOM-A c 3689 137 172 0.080 8.0 Ox0 VIFx 16.1 70.0 KrrCFEN h 4474 213 171 0.080 7.0 OxO VIFx 4.5 70.0 LAUNDRY c 68 2 3 0.080 4.0 OxO VIFx 5A 70.0 N14ZMRSATH h 752 36 19 0.080 4.0 OxO VIFx 32.9 90.0 st1 MASTERBEDROOM c 2671 107 124 0.080 7.0 OxO VIFx 27.9 90.0 st1 MASTERBEDROO" c 2671 107 124 0.080 7.0 OxO VIFx 35.9 90.0 st1 POWDER c 42 1 2 0.080 4.0 Ox0 VIFx 292 90.0 st1 SMAREA, h 718 34 13 0.080 4.0 OxO VIFx 30.9 90.0 st1 STORAGE h 794 38 12 1 0.080 4.0 Ox0 VIFx 112 70.0 Supply ' Trunk Htg Clg Design Veloc Diam HxW Dud Name Type (din) (dm) FIR (fpm) (n) (in) Material Trunk st1 PeakAVF 441 437 0.080 561 12.0 0 x 0 VlnlFlx -*- wreghtsoft® 202141 121321:41 RigttSUW&Uiv al 201919.021 RSU08101 ACCh \WrigttwRHUAaWYNNEBUIDLING-THECOTTAGEnp Calc=M1B Fmd Doorfa -SW Paget Return Bran6h Detail Table Grille Htg Clg TEL Design Ueloc Diam H x W Stud/Joist Dud Name Size(in) (Crm) (Crm) (tt) FR (fpm) (in) (n) Opening(in) Mat Trunk rb1 0x0 967 967 0 0 0 0 Ox 0 MR Wrightsoftm 20214a 121321A1 �, RigKSuhOUrivxrsa1201919.021 RSUD8101 Page ACM ...1WngYtaiftWAQWYNNEBUIDLING-THECOTTAGEnp Calc=918 FrortDoorfaces SW