HomeMy WebLinkAboutAPPROVED License Sub 6_DUNE WALK_236913_Structural Analysis_2021-02-084907 NW 43rd Street, Suite D, Gainesville, FL 32606 Structural Evaluation of Existing Rooftop Equipment Platform & Antenna Frame Verizon Wireless Cell Site Platform & Antenna Mount “Pass-Fail” Analysis Site located at: Dune Walk 7370 South Ocean Drive Jensen Beach, FL 34957 December 14, 2020 Designed in accordance with the requirements of the 7th Edition (2020) Florida Building Code, Wind Loading requirements within Chapter 16. Analysis Prepared for: Tower Engineering Professionals, Inc. Matthew K. Lackey, PE 3401 St. Vardell Lane Suite A Charlotte, NC 28217 Analysis Prepared by: Waylon Francis, EI #EI1100019320 Analysis Reviewed by: John Wayne Mishoe, PhD PE #PE25349 Stephen Matthew Belser, PE #PE67514 JWM Engineering, LLC #CA28619 Signature Date Seal: 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 1 of 65 12/14/2020 4907 NW 43rd Street, Suite D, Gainesville, FL 32606 Table of Contents Page Structural Report 3 TEP Lease Exhibit 6 TEP Antenna Frame Mapping 7 Wind Loads – Frame and Equipment 11 Wind Loads - Antennas 16 RISA 3D Exhibits 18 RISA 3D Load Distribution 32 RISA Connector Check 57 Connector & Weld Design Checks 61 Building Influence Check (Requires Verification) 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 2 of 65 4907 NW 43rd Street, Suite D, Gainesville, FL 32606 Project Scope of Work and General Conditions The scope of work for this part of the project is to structurally evaluate an existing elevated equipment platform & antenna frame and its ability to support the installation of a new outdoor equipment cabinet, antennas, and associated equipment. The proposed equipment will be replacements for the existing equipment that currently occupy the platform. The following evaluations are based upon loading requirements of the TIA-222-H standard and the 2020 Florida Building Code (FBC). This is a Verizon Wireless site located at 7370 South Ocean Drive, Jensen Beach, Florida, in St. Lucie County. The photo below shows the platform in its existing conditions prior to equipment addition: Figure 1- Existing Site Structural Analysis The analysis is based upon the following documentation provided to JWME from TEP: 1. Lease Exhibit of the proposed equipment layout, prepared by TEP, dated 12 -07-2020. 2. Antenna mount mapping data collected by Maser Consulting P.A dated, 8-27-2020. 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 3 of 65 4907 NW 43rd Street, Suite D, Gainesville, FL 32606 3. Proposed Verizon RFDS for the Dune Walk site dated, 11-9-2020. 4. Previous Pass-Fail Analysis of the Dune Walk site completed by JWME on 07-28-2016. 5. Proposed cabinet and antenna specifications provided by TEP. JWME used the best information available to analyze the impact on the building and to determine the required loading. The proposed equipment information was provided by Tower Engineering Professional, Inc. (TEP) and the data used to determine the required platform and antenna frame loads. Loads considered in the analysis include the following: 1. Wind loads were computed using ASCE 7-16 methods assuming a wind speed of 163 MPH, Building Category II, Exposure D. 2. Dead weight, live loads and associated wind loads were included based upon code minimum requirements for the roof area. 3. The table below lists the proposed equipment being added to frame and the equipment to remain: Mount Elevation (ft) Equipment Elevation (ft) Quantity Manufacture Model Status 81.88 88.00 3 - VZE01 Added 3 Ericsson 4449 3 Ericsson 8843 2 Raycap RHSDC-6627-PF-48 1 CUBE Large Support Cabinet CUBE-SS4B228LX1 6 JMA Wireless X7CQAP-665-V Retained 6 JMA Wireless DBC-67C-U-2SF 4. Other known dead weights, such as grating weights, were also added. The existing platform stud columns and associated base plate attachments were used to support a penthouse shelter. The shelter was removed and replaced with the existing platform. The total existing loading is considerably less on the existing stud columns and underlining building concrete columns than was originally placed when first constructed. Because this is an existing structure, no consideration was given to the continuous load path to the foundation. No information was provided to JWME about the existing concrete column, base plate size or connection method. A building influence of the concrete columns was 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 4 of 65 4907 NW 43rd Street, Suite D, Gainesville, FL 32606 performed to verify the minimum size concrete column necessary to support the existing platform loads with a maximum of 5% increase on overall loading in accordance with the 2020 Florida Building Code: Existing Building 707.2. The contractor must verify these assumptions and contact engineering if the assumed concrete column size is smaller than the dimensions used in the attached calculations. However, with this installation, the additional equipment it not expected to change the overall loading of the structure. Results of Analyses With the assumptions listed in this report verified, t he equipment frame has been evaluated and meets the minimum requirements of the 7th Edition (2020) FBC. The specifications are provided by JWME in the attached calculations. This evaluation assumes the current structure has been kept in good repair, code compliant and built in accordance with the record drawings. The contractor must verify these assumption s and report to the engineer any discrepancies as it may affect the results of this evaluation. 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 5 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 6 of 65 FCC # UNKNOWN Tower Owner: Site Name: Site Number or ID: Mapping Contractor: Please Insert Sketches of the Antenna Mount This antenna mapping form is the property of TES and under PATENT PENDING. The formation contained herein is considered confidential in nature and is to be used only for the specific customer it was intended for. Reproduction, transmission, publication, modification or disclosure by any method is prohibited except by express written permission of TES. All means and methods are the responsibility of the contractor and the work shall be compliant with ANSI/ASSE A 10.48, OSHA, FCC, FAA and other safety requirements that may apply. TES is not warrantying the usability of the safety climb as it must be assessed prior to each use in compliance with OSHA requirements. Antenna Mount Mapping Form (PATENT PENDING) DUNE WALK Mapping Date:08-27-2020 VZW: DUNE WALK Tower Type:Other VZW:423 Tower Height (Ft.):79 RKS Design & Engineering LLC.Mount Elevation (Ft.):90.5 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 7 of 65 Please Insert Sketches of the Antenna Mount, cont'd236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 8 of 65 Please Insert Sketches of the Antenna Mount, cont'd 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 9 of 65 Please Insert Sketches of the Antenna Mount, cont'd 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 10 of 65 Verizon Site Name: Dune WalkVerizon Site #2369137370 South Ocean DriveJensen Beach, FL 34957St. Lucie County 12/10/2020Equipment CabinetsWind Load Calculations EQUIPMENT CABINET WIND LOAD CALCULATIONS ASCE 7-10 (CH 29) Unit Definition LEGEND INPUT CALCUATIONS RESULTS Define Miscellaneous Unit Variables. plf lbf ft:=psf lbf ft2:=pcf lbf ft3:=kip 1000lbf:=ksi kip in2:=SF ft 2:=CF ft 3:= Site Location Verizon Site Name: Dune WalkVerizon Site #2369137370 South Ocean DriveJensen Beach, FL 34957St. Lucie County Codes Design Codes: 7th Edition (2020) Florida Building CodeReference Codes: ASCE 7-16, ACI 318-14 and AISC Steel Construction Manual, 14th Ed. Assumptions: Assume cabinets and frame are analyzed using Ch. 29 Chimneys, Tanks, Rooftop Equipment, & SimilarStructures Method as modified by FBC 2020 CH 16 Section 1620Assume cabinets are only carried by primary beams.Assume loading from cabinets is equivalent to point load at the center of each cabinet on each beam. Verizon Cabinet Information Modular Cell Cabinets CS 4:=*i 0 CS 1-( )..:=*j 0 CS 2-( )..:=* T:\JWME\Jobs\Tower Engineering Professionals Designed by: WM-SB MathCAD Page 1 of 5 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 11 of 65 Verizon Site Name: Dune WalkVerizon Site #2369137370 South Ocean DriveJensen Beach, FL 34957St. Lucie County 12/10/2020Equipment CabinetsWind Load Calculations Code "Cabinet Type" Lo Wo Ho lbs CSTotal number of cabinets CABINETS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 "EBRE Battery Cabinet" "BTS Cabinet - Mod 4.0B" "CUBE Cabinet Large SS Series" "Generator-trans" "Emerson Microwave" "Lucent Battery Cabinet" "LTE-ODE 6201 Ericsson" "SSC-Delta-Med. (ESOA) " "FCOA-Nokia Siemens" "10kw Fuel Cell-black hand" "15kw Fuel Cell-black hand" "Storage - Large - Fuel Cell" "Storage - Med - Fuel Cell" "LTE ODE 6201 w BRAM Bat." "MOD 4.0B w BRAM Bat." "(2) SSC-Small-Stacked " "(1) SSC - Small" "Generac 50kW NG" "Generac 50kW NG-trans" "RBA72 Cabinet" "Back Fibre Cabinet" "LP Tank" "LP Tank Trans" 36 35.4 32 72 30 31 36 29.5 30.3 26.2 26.2 39 27 36 35.4 26 26 40 92.9 30 30 37 120 38 40 32 30 31 30 36 34.1 30.3 43.2 43.2 39 39 36 40 26.75 26.75 92.9 40 39 18 120 37 78 72 84 56 98 60 72 54 61 72 94 72 72 88 88 74 37 71.2 71.2 72 36 37 37 4960 1424 1915 2750 1200 3000 715 1500 789 974 1461 1353 929 1600 2308 1574 787 2750 2750 3000 1000 940 940 21 21 60 30 21 21 21 20.3 21 21 21 21 21 21 21 21 21 35.5 85 21 14 30 100   := Rc rows CABINETS() 23=:= ii 0 Rc 1-..:= iii 0 1..:= Cabcodeii iii, CABINETSii iii, := Chose your Cabinets based off the Cabinet Code Cabinet Type &Layout for Site Cabinet Locationon Beams SITE 0 1 1 2   :=LOCATION 2.04 6.17 9.17 13.5   ft:= Equipment Name EquipVei CABINETSSITEi 1, :=EquipVe "EBRE Battery Cabinet" "BTS Cabinet - Mod 4.0B" "BTS Cabinet - Mod 4.0B" "CUBE Cabinet Large SS Series"   = T:\JWME\Jobs\Tower Engineering Professionals Designed by: WM-SB MathCAD Page 2 of 5 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 12 of 65 Verizon Site Name: Dune WalkVerizon Site #2369137370 South Ocean DriveJensen Beach, FL 34957St. Lucie County 12/10/2020Equipment CabinetsWind Load Calculations HIDDEN AREA: Calculations Building Information Lbuilding.normal.beam 109ft:=Depth of building perpendicular to cabinets support beams Lbuilding.parallel.beam 225ft:=Depth of building parallel to cabinets support beams BuildingTop.AGL 90ft:=Height of Building above grade hcab.clear 1.5ft:=Vertical distance from roof top to bottom of cabinet Lstructure 20ft:=Width of Structure perpendicular to equipment cabinet face Select Building Exposure Category as define in ASCE 7 or FBC Beamspacing 2.5ft:=Spacing Between Beams Beambf 8in:=Flange Width of Beams V 163:=Ultimate Wind Speed HIDDEN AREA: Calculations Loads Load Path Cabinet vertical loads carried by beams to girders to columns to building frame.Frame vertical loads carried by beams to girders to columns to building frame. Determine wind load on Cabinets and Frame Assume Rooftop Structures and Equipment For Buildings w/ Height <= 60 ft (ASCE 7-16 29.5.2) and Height > 60 ft (Eq29.5.1. HIDDEN AREA: Calculations SUMMARY OF CABINET REACTIONS DEAD LOADS BEAM #1 BEAM #2 EQUIPMENT RAy.DLi 2480 712 712 957.5   lbf=RBy.DLi 2480 712 712 957.5   lbf=EquipVei "EBRE Battery Cabinet" "BTS Cabinet - Mod 4.0B" "BTS Cabinet - Mod 4.0B" "CUBE Cabinet Large SS Series"   = T:\JWME\Jobs\Tower Engineering Professionals Designed by: WM-SB MathCAD Page 3 of 5 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 13 of 65 Verizon Site Name: Dune WalkVerizon Site #2369137370 South Ocean DriveJensen Beach, FL 34957St. Lucie County 12/10/2020Equipment CabinetsWind Load Calculations WIND LOADS VERTICAL REACTIONS (CASE A AND B) EQUIPMENT UPLIFT DOWN FORCE EquipVei "EBRE Battery Cabinet" "BTS Cabinet - Mod 4.0B" "BTS Cabinet - Mod 4.0B" "CUBE Cabinet Large SS Series"   =RAy.WLi 3564.2 3108 3108 4069.7   lbf=RBy.WLi 2329.8- 1830.4- 1830.4- 3145.7-   lbf= LATERAL REACTIONS (CASE A AND B)EQUIPMENT EquipVe "EBRE Battery Cabinet" "BTS Cabinet - Mod 4.0B" "BTS Cabinet - Mod 4.0B" "CUBE Cabinet Large SS Series"   =RAx.WLi 1435.7- 1303.2- 1303.2- 1374.4-   lbf=RBx.WLi 1435.7- 1303.2- 1303.2- 1374.4-   lbf= Horizontal(Load Case C&D)Moment Reactions(Load Case C&D) Rzmax 1515.5 lbf=Mmax 4925.3 lbf ft= HIDDEN AREA: Calculations Distributed Wind Loading on frame members Beamd 10in:=Beam Depth Beam2d 6in:=Beam 2 Depth Girderd 10in:=Girder Depth Columnd 8in:=Column Width Columnw 6in:=Column Depth T:\JWME\Jobs\Tower Engineering Professionals Designed by: WM-SB MathCAD Page 4 of 5 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 14 of 65 Verizon Site Name: Dune WalkVerizon Site #2369137370 South Ocean DriveJensen Beach, FL 34957St. Lucie County 12/10/2020Equipment CabinetsWind Load Calculations BeamPLF max Pz Beam d( ) 122.7 plf=:=Distributed Wind Load along Beam Beam2PLF max Pz Beam2d( ) 73.6 plf=:=Distributed Wind Load along Beam 2 GirderPLF max Pz Girderd( ) 122.7 plf=:=Distributed Wind Load along Girder Columnd.plf max Pz Columnd()98.2 plf=:=Distributed Wind Load along Column (Depth side) Columnw.pdf max Pz Columnw()73.6 plf=:=Distributed Wind Load along Column (Width side) T:\JWME\Jobs\Tower Engineering Professionals Designed by: WM-SB MathCAD Page 5 of 5 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 15 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 16 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 17 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 18 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 19 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 20 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 21 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 22 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 23 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 24 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 25 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 26 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 27 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 28 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 29 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 30 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 31 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 32 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 33 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 34 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 35 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 36 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 37 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 38 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 39 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 40 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 41 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 42 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 43 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 44 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 45 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 46 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 47 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 48 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 49 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 50 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 51 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 52 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 53 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 54 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 55 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 56 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 57 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 58 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 59 of 65 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 60 of 65 DUNE WALKVerizon Site #2369137370 South OceanJensen Beach, FL 34957 d}Connector Analysis DUNE WALK CONNECTOR/WELD CHECKS - VERIZON #236913 NOTE: Unity Codes (UC) < or = 1 pass. UC > 1 FAIL LEGEND UNIT DEFINITION INPUT CALCUATIONS RESULTS plf 1 lbf ft=psf 1 lbf ft2=pcf 1 lbf ft3=kip 1 10 3lbf=ksi 1 kip in2=SF ft 2:=CF ft 3:= Beam to Girder & Girder to Column Connection Check Girder to Column is simple connection i 2:=Total Number of Members n 0 i 1-..:= Member Dimensions Member0 "W10x33":=Label 0 "Girder-1":=b f 0 8in:=d 0 9.73in:=tf 0 0.435in:=tw0 0.29in:=Sx0 35in3:= Member1 "W10x33":=Label 1 "Beam-2":=b f 1 8in:=d 1 9.73in:=tf 1 0.435in:=tw1 0.29in:=Sx1 35in3:= fy 50ksi:=Yield Strength fu 65ksi:=Ultimate Strength Shear and Tension Values Per Member from RISA Model Label "Girder-1" "Beam-2" =Ty 0 6268 lbf:=Vz 5073 7040 lbf:=Vx 6272 14908 lbf:= Torsion and Moment Values Per Member from RISA Model Label "Girder-1" "Beam-2" =My 6224 5248 lbfft:=Mz 8165 47141 lbf ft:=MT 48 0 lbf ft:= Bolt Information Bolt0 "A325X":= dbolt .875 .875 in:=Bolt Diameter Fnv.b 68ksi:=Nominal Shear Strength Numbolts 4 4 :=Assumed number of bolts Fnt.b 90ksi:=Nominal Tension Strength Hidden Area: Calculations T:\JWME\Jobs\Tower Engineering 1 of 4 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 61 of 65 DUNE WALKVerizon Site #2369137370 South OceanJensen Beach, FL 34957 d}Connector Analysis X2 5.125 5 in:=X1 5.125 5 in:= Hidden Area: Calculations 3.1 0.75:=LRFD Factor Shear capacity (1) 3/4" A325-X Bolt in single shear(J3-1, AISC)Shearbolt 3.1 Fnv.bAb30.7 30.7 kip=:= Tension capacity of (1) 3/4" A325-X Bolt in tension(J3-1, AISC) Tensionbolt 3.1 Fnt.bAb40.6 40.6 kip=:= UCshear Shear perbolt Shear bolt 0.1 0.1 =:=Unity Code for Shear UCtension Tensionperbolt Tensionbolt 0.2 0.3 =:=Unity Code for Tension 3.2 0.75:=LRFD (J3-3b AISC) Fnt.J3.3bn 1.3Fnt.b Fnt.b 3.1 Fnv.b Shear n Ab n Numboltsn-... ksi=:= Fntn Fnt.J3.3b Fnt.J3.3bn Fnt.bif Fnt.b otherwise j nfor ... ksi=:= Rn.J3.2n 3.2 FntAb... kip=:=Rn.J3.2 81.2 81.2 kip=Combined Tension and Shear inBearing Type Connection (J3-2, AISC) UCJ.3.2 Ty Rn.J3.2 0.0 0.1 =:=Unity Code of Available Tensile Strength ofBolt suject to combined tension and shear Strength Reduction for Members with Holes in Tension Flange (F13 AISC 15th Ed.) Afn tf b f Numbolts0 2 dbolt 1 16 in+tf-5.329 in 2=:= T:\JWME\Jobs\Tower Engineering 2 of 4 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 62 of 65 DUNE WALKVerizon Site #2369137370 South OceanJensen Beach, FL 34957 d}Connector Analysis Afg tf b f6.96 in 2=:= I13check "Limit State DNA" fu Afnfy Afgif "Check New Mn" otherwise "Check New Mn"=:= I13check "Check New Mn"= Mn Afn Afg fuSx0145.15 kip ft=:= TensionMax M n 0.1 0.1 = Base Plate Antenna Column Weld Check Column0 "5.0X PIPE":= ASTM A500 B Fy.c 35ksi:=tc 0.349in:=Column Wall Thickness Fu.c 60ksi:=d c 5.56in:=Column Depth pc d c 17.467 in=:=Permeter of Column lweld p c 17.467 in=:=Length of Weld Weld Thicknesstweld6 16 in:= # of 16th of inch in weldDweldtweld16 in6=:= Fbolt 2671lbf:=Tension in one bolt From RISA BASE Vz.c 6332lbf:=Shear Force on Weld (Z axis from RISA) Vx.c 522lbf:=Shear Force on Weld (X axis from RISA) Zshear Vz.c2 Vx.c2+6.353 kip=:=Vector Component of Shear Force on Weld Mx.tension 6757lbf ft:=Moment on Weld X-Axis (From RISA) My.tension 320lbf ft:=Moment on Weld Y-Axis (From RISA) Hidden Area: Calculations T:\JWME\Jobs\Tower Engineering 3 of 4 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 63 of 65 DUNE WALKVerizon Site #2369137370 South OceanJensen Beach, FL 34957 d}Connector Analysis Fexx 70ksi:=E70 Electrode Hidden Area: Calculations j2.4 0.75:=LRFD Factor Rn.j2.4 j2.4 FnwAwe308.7 267.7 kip=:=Weld Strength Eq. J2-4 lmin.weld.req Freq.weld j2.4 Fnwlweld 0.3 0.4 in 16=:=Minimum weld Thickness UC Rn.j2.4 Freq.weld Rn.j2.4 0.1 0.1 =:=Unity Code tweld.min 3.09 Dweld Fu.c ksiin4.9 in 16=:= tweld.min.check "OK" t weld.min tweldif "weld to thin for connecting column" otherwise "OK"=:= T:\JWME\Jobs\Tower Engineering 4 of 4 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 64 of 65 Verizon Site Name: Dune WalkVerizon Site #2369137370 South Ocean DriveJensen Beach, FL 34957St. Lucie County 12/10/2020Building Influence Check BUILDING INFLUENCE CHECK ON EXISTING CONCRETE COLUMN LEGEND Unit Definition INPUT CALCUATIONS RESULTS Define Miscellaneous Unit Variables. plf 1 lbf ft=psf 1 lbf ft2=pcf 1 lbf ft3=kip 1 10 3lbf=ksi 1 kip in2=SF ft 2:=CF ft 3:= Site Location Verizon Site Name: Dune WalkVerizon Site #2369137370 South Ocean DriveJensen Beach, FL 34957St. Lucie County NOTES: This mathcad sheet checks the influence of the imposed verticle load on an existing building concrete1.column axial axis per 2020 FBC:EB 707.2. n 1:=Number of Columns Checked i 0 n 1-..:= Lcol 14( )in:=Length of Concrete Column Wcol 14( )in:=Width of Concrete Column HIDDEN AREA: Calculations fc 3000psi:=Concrete Strength frebar 60ksi:=Rebar Strength Fy.max 14948( )lbf:=Maximum Vertical Load from RISA at Column, worst case load combination (LFRD Value) 10.2 0.65:=LFRD Factor HIDDEN AREA: Calculations Loadchecki Fy.max i Pn.10.2i  := Loadcheck 4.694( ) %=Percent Increase in of Load on Column's Capacity HIDDEN AREA: Calculations Result "Less than 5% increase in Column Capacity, no further analysis needed per 2020 FBC:EB 707.2."()= T:\JWME\Jobs\Tower Engineering Professionals JWM Engineering, LLC 1 of 1 236913 Dune Walk Platform & Antenna Frame Pass-Fail Report 12/14/2020 65 of 65