ENGINEERING
/ SCE 7-16]1iftnd Loads Wind speed V= 170 mph Exposure-'D'EaSySeOlS , easyseals.com For Wall Components & Cladding Ke= 1.0 ASD Load Combination CoeFF.0.6 Wind Pressures[psf]For use with Allowable Stress Design K2t= 1.0 I(d= 0.85 Enclosed Bldg GCpi= 0:18 Triburary area at least... Triburary area at least... Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Triburary area at least Mean 30 sq ft 15 sq ft 20 sq ft 25 sq ft 30 sq ft 35 sq ft 40 sq ft 50 sq ft Roof Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Zone 4 Zone 5 Height Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner Interior Corner 60'to: + + + + + + + - + - + - + - + - + - + - + - + - + - 61 ft +53.6-53.6 +53.6-98.2 +53.6-53.6 +53.6-98.2 +53.6-53.6 +53.6-98.2 +52.6-52.9 +52:6-95.5 +51.7-52.3 +51.7-93.2 +51.0-51.9 +51.0-91.3 +50.4-51.4 +50.4-89.7 +49.3-50.8 +49.3-86.9 65 ft +54.2-54.2 +54.2-99.3 +54.2-54.2 +54.2-99.3 +54.2-54.2 +54.2-99.3 +53.1-53.5 +53.1-96.5 +52.3-52.9 +52.3-94.3 +51.6-52.4 +51.6-92.3 +50.9-52.0 +50.9-90.7 +49.9-51.3 +49.9-87.9 70 ft +54.9-54.9 +54.9-100.6 +54.9-54.9 +54.9-100.6 +54.9-54.9 +54.9-100.6 +53.8-54.2 1 +53.8-97.8 +53.0-53.6 +53.0-95.5 +52.2-53.1 1 +52.2-93.5 +51.6-52.7 +51.6-91.9 +50.5-52.0 1 +50.5-89.0 75 ft +55.5-55.5 +55.5-101.8 +55.5-55.5 +55.5-101.8 +55.5-55.5 +55.5-101.8 +54.5-54.8 +54.5-99.0 +53.6-54.2 +53.6-96.6 +52.9-53.7 +52.9-94.7 +52.2-53.3 +52.2-93.0 +51.2-52.6 +51.2-90.1 80 ft +56.2-56.2 +56.2-103.0 +56.2-56.2 +56.2-103.0 +56.2-56.2 +56.2-103.0 +55.1-55.4 +55.1-100.1 +54.2-54.9 +54.2-97.7 +53.5-54.4 +53.5-95.7 1 +52.8-53.9 +52.8-94.0 +51.7-53.2 +51.7-91.1 85 ft 1 +56.8-56.8 +56.8-104.1 +56.8-56.8 +56.8-104.1 +56.8-56.8 +56.8I-104.1 +55.7-56.0 +55.7-101.1 +54.8-55.4 +54.8-98.8 +54.0-54.9 +54.0-96.8 +53.4-54.5 +53.4-95.0 +52.3-53.8 +52.3-92.1 90 ft +57.3-57.3 +57.3-105.1 +57.3-57.3 +57.3-105.1 +57.3-57.3 +57.3-105.1 +56.2-56.6 +56.2-102.2 1 +55.3-56.0 1 +55.3-99.8 +54.6-55.5 +54.6-97.7 1 +53.9-55.0 +53.9-96.0 +52.8-54.3 +52.8-93.0 95 ft +57.9-57.9 +57.9-106.1 +57.9-57.9 +57.9-106.1 +57.9-57.9 +57.9-106.1 +56.8-57.1 +56.8-103.1 +55.8-56.5 +55.8-100.7 +55.1-56.0 +55.1-98.6 +54.4-55.6 +54.4-96.9 +53.3-54.8 1 +53.3-93.9 100 It +58.4-58.4 +58.4-107.1 +58.4-58.4 +58.4-107.1 +58.4-58.4 +58.4-107.0 +57.3-57.6 +57.3-104.0 +56.3-57.0 +56.3-101.6 +55.6-56.5 +55.6-99.5 +54.9-56.1 1 +54.9-97.7 1 +53.8-55.3 +53.8-94.7 . 105 ft +58.9-58.9 1 +58.9-108.0 +58.9-58.9 +58.9-108.0 +58.9-58.9 +58.9-108.0 +57.8-58.1 +57.8-104.9 +56.8-57.5 +56.8-102.5 +56.0-57.0 +56.0-100.4 +55.4-56.5 +55.4-98.6 +54.2-55.8 +54.2-95.5 110 ft 1 +59.4-59.4 +59.4-108.8 +59.4-59.4 +59.4-108.8 +59.4-59.4 1 +59.4-108.8 +58.2-58.6 1 +58.2-105.8 +57.3-58.0 +57.3-103.3 +56.5-57.5 +56.5-101.2 +55.8-57.0 +55.8-99.4 +54.7-56.2 +54.7-96.3 115 ft +59.8-59.8 +59.8-109.7 +59.8-59.8 +59.8-109.7 +59.8-59.8 +59.8-109.7 +58.7-59.1 +587 1066 +57.7-58.4 +57.7-104.1 +56.9-57.9 +56.9-102.0 +56.3-57.4 +56.3-100.1 +55.1-56.7 +55.1-97.1 120 ft +60.3-60.3 +60.3-110.5 +60.3-60.3 +60.3-110.5 +60.3-603 +60.3-110.5 +59.1-59.5 +58.2-58.9 +58.2-104.9 +57.4-58.3 +57.4-102.7 +57-57.9 +56.7-100.9 +55.5-57.1 +55.5-97.8 +60.7-60.7 +60.7-111.3 +60.7-60.7 +60.7-111.3 +60.7-60.7 +60.7-111.3 +59.5-59.9 +595-108.2 +58.6-59.3 +58.6-105.6 +57.8-58.7 +57.8-103.5 +57.1-58.3 +57.1-101.6 +55.9-57.5 +55.9 95 130 ft .9-108.9+61.1-61.1 +61.1-112.1 +61.1-61.1 +61.1-112.1 +61.1-61.1 +61.1-112.0 +59.9-60.3 +59 +59.0-59.7 +59.0-106.3 +58.2-59.1 +58.2-104.2 +57.5-58.7 +57.5-102.3 +56.3-57.9 +56.3-99.2 135 +61.5-61.5 +61.5-112.8 +61.5-61.5 +61.5-112.8 +61.5-61.5 +61.5-112.8 +60.3-60.7 +60.3-109.6 +59.4-60.1 +59.4-107.0 +58.5-59.5 +58.5-104.9 +57.8-59.1 +57.8-103.0 +56.7-58.3 +56.7-99.8 140 ft +61.9-61.9 +61.9-113.5 +61.9-61.9 +61.9-113.5 +61.9-61.9 +61.9-113.5 +60.7-61.1 +60.7-110.3 +59.7-60.5 +59.7-107.7 +58.9-59.9 +58.9-105.5 +58.2-59.4 +58.2-103.6 +57.0-58.6 +57.0-100. 4 145 ft +62.3-62.3 +62.3-114.2 +62.3-62.3 +62.3-114.2 +62.3-62.3 +62.3-114.2 +61.1-61.5 +61.1-111.0 +60.1 60.8 +60.1-108.4 +59.3-60.3 +59.3-106.2 +58.6-59.8 +58.6-104.3 +57.4-59.0 +57.4-101. 1 150 ft +62.7-62.7 +62.7-114.9 +62.7-62.7 +62.7-114.9 +62.7-62.7 +62.7-114.9 +61.5-61.8 +61.5-111.7 +60.5-61.2 +60.5-109.0 +59.6-60.6 +59.6-106.8 +58.9-60.2 +58.9-104.9 +57.7-59.4 +57.7-101.7 155 ft +63.0-63.0 +63.0-115.5 +63.0-63.0 +63.0-115.5 +63.0-63.0 +63.0-115.5 +61.8-62.2 +61.8-112.3 +60.8-61.5 +60.8-109.6 +60.0-61.0 +60.0-107.4 +59.2-60.5 +59.2-105.5 +58.0-59.7 +58.0-102.2 160 ft +63.4-63.4 +63.4-116.2 +63.4-63.4 +63.4-116.2 1 +63.4-63.4 +63.4-116.2 +62.1-62.5 +62.1-112.9 +61.1-61.9 +61.1-110.3 +60.3-61.3 +60.3-108.0 +59.6-60.8 1 +59.6-106.1 +58.4-60.0 +58.4-102.8 165 ft +63.7-63.7 +63.7-116.8 +63.7-63.7 +63.7-116.8 +63.7-63.7 +63.7-116.8 +62.5-62.9 1 +62.5-113.5 +61.5-62.2 +61.5-110.8 +60.6-61.6 +60.6-108.6 +59.9-61.2 +59.9-106.6 +58.7-60.3 +58.7-103.4 170 ft +64.0-64.0 +64.0-117.4 +64.0-64.0 +64.0-117.4 +64.0-64.0 +64.0-117.4 +62.8-63.2 +62.8-114.1 +61.8-62.5 +61.8-111.4 +60.9-62.0• +60.9-109.1 +60.2-61.5 +60.2-107.2 +59.0-60.7 +59.0-103.9 175 ft +64.4-64.4 +64.4-118.0 +64.4-64.4 +64.4-118.0 +64.4-64.4 +64.4-118.0 +63.1-63.5 +63.1-114.7 +62.1.-62.9 +62.1-112.0 +61.3-62.3 +61.3-109.7 +60.5-61.8 +60.5-107.7 +59.3-61.0 +59.3-104.4 180 ft +64.7-64.7 +64.7-118.6 +64.7-64.7 +64.7-118.6 +64.7-64.7 +64.7-118.6 +63.4-63.8 +63.4-115.2 +62.4-63.2 +62.4-112.5 +61.6-62.6 1 +61.6-110.2 +60.8-62.1 +60.8-108.3 +59.6-61.3 +59.6-104.9 185 ft +65.0-65.0 +65.0-119.1 +65.0-65.0 +65.0-119.1 +65.0-65.0 +65.0-119.1 +63.7-64.1 +63.7-115.8 +62.7-63.5 +62.7-113.1 +61.8-62.9 +61.8-110.8 +61.1-62.4 +61.1-108.8 +59.8-61.6 +59.8-105.4 190 ft +65.3-65.3 +65.3-119.7 +65.3-65.3 +65.3-119.7 +65.3-65.3 +65.3-119.7 1 +64.0 1--64.4 +64.0-116.3 +63.0-63.8 +63.0-113.6 +62.1-63.2 +62.1-111.3 +61.4-62.7 +61.4-109.3 _+60;1-61.8,=. .+60. -105.9 +64.3-1169 +63 :4 10.2 65.6 65.6 + +64.3-64.7 195 ft +65.6-65.6 +65.6- 7 -65.9 +65.9- 0. -65.9 65.9-120.8 + 5.9-6 .9 -120.8 +64.6- -64.3 -63.7 -112.3 -63.2 -10066.9200 ft +65.9 ) 4- - • -..,. Ln •Design conforms to the Florida Building Code 7th Ed(2020). •Wind Speed noted above Is ultimate design wind speed(3-second gust). •Zones 4&5("Interior"and"comer"zones,respectively)are as shown to a dH gineer's " LU •Tabulated design wind loads are based on ASCE 7-16 specifications for •Plus(+)&minus(-)signs signify pressures acting toward and away from the right,where the dimension"a"Is the minimum of 10%of the building's `,. �•'�; `""`-'��y; r sr; 4=',a signature raIi ed'seaG C components and cladding based on design criteria as noted herein. the exterior component or cladding surface,respectively. least horizontal dimension or 40%of the mean roof height,but never less `,c` ... _ _ •�-'=' '- Z •Where this document is used for permit,applicability of design criteria •Where"Mean(average)Roof Height"Cannot be determined,peak roof than 3'-0"or 4%of the least horizontal dimension. � , ?,6x:�, ".��:- _ e^�•,_ -` noted herein(Basic Wind Speed,Exposure Category,Risk Category,etc.) height shall be used,except that eave height shall be used for roof angle •This spec(flication Is valid only for use with structures NOT located In the v•5 iane_ L. •��---� shall be verified by the contractor&building official prior to construction. less than or equal to 10°. Round up to values shown upper one-half of an isolated hill,ridge or escarpment,&below 1000'elev. Sty 4 c�5 ,LiY Z8 2 C •This specification maybe used in conjunction with engineering under •Wind pressures are applicable to all building floors. •This specification Is valid for use with buildings of any Risk Category, � :rr�:•� ;`. separate certification(by this engineer or by others)using Allowable Stress •Tabulated wind pressures are valid for all roof slopes;no reduction for Including essential facilities and buildings or other structures that , - ,J -x-, Z Christian='an"g'le "•PE``v L1J Design(ASD). roof slope 5 10°has been considered. represent a substantial hazard to human life In the event offailure. - 'f :"._.- a •Refer to the above-noted ASCE 7 standard for descriptions and •Tributary Area noted In table(effective wind area)Is equal to the •Design is based on structure classification as Enclosed Bldg C, - .#31124 U a_•t�F,L:PE•#67382-'= definitions of all design criteria. minimum of[height x width)or(ht x ht/31.Round down to values shown. 'v'•"�C-T-- - t'-'> -_ _ WALL ELEVATION d---,-•-�4,=--� .>`•..-,-4' 1200 N Federal Hwy,#200,Boca Raton,FL 33432 Copyright©2021 Easy Seals rev 04/21 ,s'_? f?j�.dC'1N64 16MS.17.OD