HomeMy WebLinkAboutLAYOUT=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
a TO DETERMINE IF MULTIPLE PLY. f
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Sp nor less �eA Spree der Bar
•
a �mr�m
60 degrees
or less
Tag line if 112 span to
0 1!2 ofSpan. Tag line �lpprox 2/3 n. —�
approx.
REFER TO BCSI REFER TO BCSI
Truss must be set this way if crane is used. Truss must be set this way if crane is used.
Truss is an example, your truss may not match. Truss is an example, your truss may not match.
Insist crane operator sets truss this way. Insist crane operator sets truss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated height before trusses
are installed.
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
WARNING
a`
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
REPRESENTS THE LEFT SIDE OF
EACH TRUSS DRAWING
SEAT PLATES BY CHAMBERS TRUSS
�� \, REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR 4X2 EXCEPT AS SHOWN
CARRIED
TRUSS
CARRYING
TRUSS
ANGERID
[HD26-2
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
RA5
RA
12 -10 D
18 -16 D
GR135
GRB
THD26-2
12 -10D
18 -16D
GRG
GRF
THD26-2
12 -10D
18 -16D
*Please refer to Standard Engineering package for general instuction on installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1/2"
Hatch Legend
CEILING
AT 9'-10"
CEILING
AT 1 V-8"
INDICATES
VOLUME
CEILING
LOAD
BEARING
AT 9'-0"
LOAD
BEARING
AT 11'-0"
LOAD
BEARING
AT 13'-0"
0
ao
m
Do not stand on trusses until they are braced per BCSI &
3
z ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A
properly nailed to
straps
and
hangers !!
SPREADER
BAR
OF
41'
- 46'
IN
LENGTH!!
5-00-00 E 18-00-00 31-08-00 33-00-00 I
i'" 0®/®�®®/Al %®®/.°s ®/IIIll /iVA' W0i:®®A!VZ,M:VAVZO! WZZA I /.I%®% ®/®oi%®//�%lVZ
8-00-00 1 33-08-00
NOTES:
ALL BEAMS ARE BY OTHERS
I
I
I
I
I
L
)
I
I
I
I
I
I
I
I
I
I
I
I
I
I
iNI
I
N
1
It
0
:>
� 12
>
`sue
i >
Isg
11-04-00
8-00-00
BUILDER TO UNDER FRAME CEILINGS AS NEEDED.
LEVEL RET
CEILING HE
®1
H&Mllli
v4
Ml■\■IMMIX
I
I
o
9
�
l
o
0
o 0
4
I
I
ATK
I
ATK
I
ATK
I
ATK
I
I
ATK
I
I
ATK
I
ATK
I
I
ATG
I
ATG
I
ATG
I
I
ATG
I
I
ATG
ATG
24-08-00
G�
J5D
2-08-00
JRNS ARE BY BUILDER IF DESIRED.
IGHTS ADJUSTED FOR ENGINEERING PURPOSES.
G6
G4
G3
HIP CARRIER LOCATED AS DIMENSIONED ON LAYOUT
,., FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The undersigned acknowledges and agrees:
CORNOERJACKS ��
! 1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for
ARE NOT BEVELED. _
SEE STANDARD ¢
determining successful fabrication of the trusses.
ENGINEERING o� J
2. All dimensions in this layout have been verified by the undersigned.
�000
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the.
undersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss
shall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
"
After 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of "BCSI" summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has
the sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
be responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss has
to redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
CORNER JACKS
U1111
responsible to Chambers Truss for towing costs due to site conditions.
ONLY 24"
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour'.
CORNER DETAIL
fee for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price.
OVERHANGS
:Invoice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
NOT SHOWN FOR CLARITY
- - --_ -
delivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
reasonable attorneys fee for collections in event of a ment not timely made. 1-1/2 /D per month service charge will be
Y payment Y ° P 9
UNSUPPORTED JACK CONNECTION DETAIL
added for all sums not aid within terms.
P
MTS,S strap (or aGueover Top Chord and under Bottom Chord with ,Od x,.S"
nails: 7 nails in Cartierr over
nails 7 in Hip Carrier
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
� .
Double straps for 5' Jacks
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees
'
payment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the',
undersigned agrees to pay such indebtedness including attorney's fees, if default in payment for material be made by the
CARRIED JACK HIP ARRIER
recipient.
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to',
herein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
11. Design responsibilities are per [ENational Standard And Recommended Guidelines On Responsibilities For
'Construction Using Metal Plate Connected Wood Trusses ANSI/TPIIWTCA 4 - 200200
5'
12. Warranty is per Chambers Truss Warranty attached.
Trusses beginning "JU" and
other unsupported truss should
'.
be installed this way.
DATED
SIGNED
FOR TITLE
A spreader bar may be required per "BCSI" to prevent injury & damage.
99"
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT 9'-0" 12
END DETAIL: MASTER BED 5 r-
0: 00
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT 1 V-0"
END DETAIL: DINING
4-0':r
1
-06-00 2-02-00
9"�
Temporary and permanent bracing are required and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
k
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
AA •IAT I.IwT� I I TI11Iw wI�w • Iw •IIw w. •.w �
MITEK VERSION 7.4.1.431
LOADINGMESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 1604.6.1
DESIGN CRITERIA
County
ST. LUCIE
Building Department
ST. LUCIE COUNTY
Wind Design Criteria
ASCE 7-16
Wind Design Method
MWFRS(Directional)/C-C
hybrid Wind ASCE 7-16
Roofing Material
Shingle or Shake
Loading in PSF
Roof R.D.L.
Floor
Top Chord Live
20
0
Top Chord Dead
7 4.2
0
Bottom Chord Live
*10-Non Conccurent
0
Bottom Chord Dead
10 3
0
Total Load
47 7.2
0
Duration Factor
1.25
0
Wind Speed
160mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
17'
Building Type
Enclosed
Building Category
II: Non Restrictive
Exposure Category
C>Open Terrain with scattered
obstructions
Miles from Ocean
5
Conforms to Florida Building Code
2020
R.D.L.=Restraining Dead Load
-
C.B.=Continuous Bracing
Verify DESIGN CRITERIA shown above with the
building department and your
engineer.
Design Criteria is the responsibility
of the
Building Desi ner and/or En inner
of Record
PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT VARIES
END DETAIL: TYPICAL
1-06-
1
12
5r
Chambers Truss Inc. Drawing Name: 77363
SCALE: 3/16" = 1'-011
193 total trusses, 78 unique designs
Designer: RLC Reviewed by: RLC
Date: 03/22/21 REVISED 06/08/21
FOR
RON RAYMOND
DESCRIPTION:
FOLEY RESIDENCE
Page 1 of 1 CUSTOMER INITIALS EACH PAGE