Loading...
HomeMy WebLinkAboutHealth Department ApprovedSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Marvin AGENT: PROPERTY ADDRESS: 11600 Twin creeks Dr (GUEST HOUSE) Fort Pierce, FL 34945 LOT: BLOCK: APPLICATION #:AP1578437 PERMIT #:56-SF-2166975 DOCUMENT # : F 11660696 DATE PAID:09/15/2020 FEE PAID:660.00 RECEIPT #:56-PID-4669921 SUBDIVISION: ID# : 2333-234-0001-000-5 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION [01] TANK SIZE [1] 1090.00 [2] [ 02 ] TANK MATERIAL Polypropylene [03] OUTLET DEVICE [04] MULTI -CHAMBERED [ Y N ] [051 OUTLET FILTER Polylok PL-68 [06] LEGEND 1. 70-143-11DC4 2. [071 WATERTIGHT [081 LEVEL [09] DEPTH TO LID DRAINFIELD INSTALLATION [10] AREA [1] 540 [2] SQFT [11] DISTRIBUTION BOX HEADER X (121 NUMBER OF DRAINLINES 1. 6.00 2. [13] DRAINLINE SEPARATION [14] DRAINLINE SLOPE [15] DEPTH OF COVER SETBACKS [ ] [27] SURFACE WATER FT [ ] [28] DITCHES FT [ ] [29] PRIVATE WELLS 100 FT [ ] [30] PUBLIC WELLS FT [ ] [311 IRRIGATION WELLS 100 FT [ ] (32] POTABLE WATER 73 FT [ ] [33] BUILDING FOUNDATIONS 7 FT [ ] [34] PROPERTY LINES 100 FT [ ] [35] OTHER FT FILLED / MOUND SYSTEM [ ] [36] DRAINFIELD COVER [ ] [37] SHOULDERS [ ] [381 SLOPES [ ] [39] STABILIZATION 07/02/2021 [16] ELEVATION [ ABOVE / BELOW ]BM 1.00 [ ] [171 SYSTEM LOCATION [ l [181 DOSING PUMPS [ ] [19] AGGREGATE SIZE [ ] (201 AGGREGATE EXCESSIVE FINES [ ] [21] AGGREGATE DEPTH [ ] [ ] ADDITIONAL INFORMATION [40] UNOBSTRUCTED AREA [411 STORMWATER RUNOFF [42] ALARMS [43] MAINTENANCE AGREEMENT [441 BUILDING AREA [451 LOCATION CONFORMS WITH SITE PLAN [46] FINAL SITE GRADING FILL / EXCAVATION MATERIAL [ ] [47] CONTRACTOR (KRK Enterprises) [ ] [22] FILL AMOUNT [ ] [48] OTHER ADS MPS-9 (9 pipes - 2 tier) [ ] [23] FILL TEXTURE [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. / _ St. Lucie CHD DATE: 03/15/2021 CONSTRUCTION [ APPROVED DISAPPROVED ] ' Environmental Specialist III rian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED St. Lucie CHD DATE: O7/O2/2021 Environmental Specialist I Mathew�6 anyi (Florida Department of He (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1578437 EID2166975 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1578437 PERMIT #:56-SF-2166975 DOCUMENT # : FI 1660696 DATE PAID.09/15/2020 FEE PAID:660.00 RECEIPT #:56-PID-4669921 The system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of 300 gpd. New ST, filter, and 6x30' long BED DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for mound system, gutters, and final site grading. Final inspection completed. Mound system checked, gutters added, and final site grading completed. Contractor emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1578437 EID2166975