HomeMy WebLinkAboutHealth DeptSTATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL APPLICANT: Adams Homes of Northwest Florida, Inc AGENT: Benjamin Drew"s Plumbing & Drain Services PROPERTY ADDRESS: 5611 Spruce Dr Fort Pierce, FL 34982 APPLICATION # : AP1464945 PERMIT #:56-SF-2034819 DOCUMENT # : F 11662791 DATE PAID : 01 /30/2020 FEE PAID :545.00 RECEIPT #:56-PID-4284769 LOT: 22 SUBDIVISION: BLOCK: 77 Indian River Estates ID#: 3402-610-0207-000-7 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 1090.00 [2] [ ] [271 SURFACE WATER FT [ ] [02] TANK MATERIAL Polypropylene [ ] [281 DITCHES 23 FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS FT [ ] [04] MULTI -CHAMBERED [LIJ N ] [ ] [30] PUBLIC WELLS FT [ ] [051 OUTLET FILTER Polylok PL-68 [ ] [31] IRRIGATION WELLS FT [ ] [06] LEGEND 1. 70-143-11DC4 2. [ ] [32] POTABLE WATER 30 FT [ ] [07] WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 6 FT [ ] [081 LEVEL [ ] [34] PROPERTY LINES 8 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 388 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ) [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 5.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 07/13/2021 [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION ( ] [16] ELEVATION [ ABOVE / BELOW ]BM 3.00 [ ] [40] UNOBSTRUCTED AREA [ ] [17] SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [42] ALARMS [ ) [19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ) [20) AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [21] AGGREGATE DEPTH [ ] [451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ) [46] FINAL SITE GRADING [ ] [22] FILL AMOUNT [ ) [47] CONTRACTOR Bruce T Mc Cullers (Reliable T [ ] [23) FILL TEXTURE [ ) [48] OTHER PTI MPRDS (9 pipes - 2 tier) [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25) AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. / t. Lucie CHD DATE: 03/18/2021 CONSTRUCTION [ APPROVED DISAPPROVED ] ' nvironmental Sp ialist 11 Ni le Monta a (Florida Department of He FINAL SYSTEM [ APPROVED / DISAPPROVE t.Lucie CHD DATE: 07/13/2021 Environmental S ecialis II Ni ole Montnd) Flo Department of He (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be u Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1464945 EID2034819 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION # : AP 1 464945 PERMIT # : 56-S F-2034819 DOCUMENT #: F11662791 DATE PAID . 01 /30/2020 FEE PAID :545.00 RECEIPT #:56-PID-4284769 Fgp6The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300 . New ST and 2x24 + 1x25.5 + 2x28 TRENCH DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for mound system and final site grading. Final inspection approved. Emailed copy to building department and contractor. NMM DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1464945 EID20348i9