HomeMy WebLinkAboutApproved Plans REV DATE DESCRIPTION
A 4/6/21 PRELIMINARY
B 4/9/21 REVISED
A2P004513
C 4/1 REVISED
0 5/7/21/21 FOR PERMIT
MICROWAVE
O APX PROJECT NO.:
SERVICE COMPANY 21-0270.13
■ R DRAWN BY: R. G ARCIAARCIA
CHECKED BY: M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
6189 N US— 1 THIS OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
T IS FORBIDDEN WITHOUT THE WRITTEN
FORT PIERCE, FL 34951
PERMISSION OF THE OWNER.
EXCALIBUR INSTALLATION A
LOCAL MAP PROPERTY SUMMARY PROJECT DESCRIPTION INDEX OF DRAWINGS cl
FOLIO 1. THE WIRELESS COMMUNICATIONS FACILITY IS NOT INTENDED FOR SHT. DESCRIPTION REV. ® O
HUMAN OCCUPANCY. NO. NO. ENGINEERING GROUP
1406-413-0003-000-8 T1 TITLE SHEET 0 14471 MIRAMAR PARKWAY, SUITE 202
2. THIS FACILITY DOES NOT REQUIRE POTABLE WATER AND MIRAMAR, FL 33027
PROPERTY OWNER WILL NOT PRODUCE ANY SEWAGE. T2 GENERAL NOTES 0 (954) �44-1538
CERTIFICATE OF AUTHORIZATION 31948
n MARY JANE SPAIN (TR) 3. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS C1 COMPOUND PLAN 0
cypres U;r PO BOX 1149 AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY C2 EQUIPMENT PLANS 0
Mob HOBE SOUND, FL 33475 NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFOR41 E
4 PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME.
�a LATITUDE 4. THE SCOPE OF WORK CONSISTS OF MODIFYING THE EXISTING
27.546333' N WIRELESS INSTALLATION:
Pineapple-ji5o ■ -Mobile
�
crlll&Raw Bar�1 LONGITUDE REMOVAL OF (2) EXISTING EQUIPMENT CABINETS C6 DETAILS 0
REMOVAL OF (9) EXISTING ANTENNAS E1 ELECTRICAL AND GROUNDING NOTES 0
71 Atlaotro Hardscapes� 80.368583° W REMOVAL OF (9) EXISTING RRUS
ZONING JURISDICTION REMOVAL OF (1) EXISTING COVPS E2 UTILITY ROUTING PLAN 0
REMOVAL OF (3) EXISTING ANTENNA MOUNTS E3 UTILITY ROUTING PLAN 0
e/ m, ST LUCIE COUNTY INSTALLATION OF (2) PROPOSED EQUIPMENT CABINETS E4 ELECTRICAL DETAILS 0
INSTALLATION OF (2) PROPOSED HYBRID CABLES
¢�¢ INSTALLATION OF (6) PROPOSED ANTENNAS E5 GROUNDING DETAILS 0 oo�\E?E?rD/yz,,,
�c 1 INSTALLATION OF (9) PROPOSED RRUS GEN° ;
INSTALLATION OF (3) PROPOSED ANTENNA MOUNTS '.;' 218 ++=
INSTALLATION OF (1) PROPOSED SERVICE LIGHT
S, T TE/
AycackF1 raf
Home&HIIlcresL..Q
VICINITY MAP CODE COMPLIANCE DESIGN CRITERIA
ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN BASIC WIND SPEED: 160 MPH (ULTIMATE, 3—SECOND GUST) Digitally signed y
�3 saefr, ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES EXPOSURE: C E L I EZ E R D I Z
® Oslo AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN RISK CATEGORY: II
Florida Ridge THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT OPEN STRUCTURE
N CONFORMING TO THESE CODES. Date. 2021 .06. 3
1. FLORIDA BUILDING CODE, 7th EDITION (2020).
2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70-17, NATIONAL
Inmen River ELECTRICAL CODE, 2017 EDITION.
Uero Beach A2 P 0 0 45 B
to R.Pierce
3. ASCE 7-16. MICROWAVE
► 4. TIA-222—H WITH APPLICABLE STANDARDS. CALL 48 HOURS SERVICE COMPANY
Lakewo� 1 BEFORE YOU DIG
Park 5. LIFE SAFETY CODE NFPA-101-2018.
O
6189 N US-1
6. FLORIDA FIRE PREVENTION CODE, 7th EDITION (2020). IT'S THE LAW FORT PIERCE, FL 34951
1-800-432-4770 SHEET NAME
7. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) 360-16 AND
_ 341-16.
O O mar°ae SUNSHINE STATE ONE CALL OF FLORIDA, INC.
O C� 8. UNDERWRITERS LABORATORIES (U.L.) APPROVED ELECTRICAL TITLE SHEET
PRODUCTS.
9. LOCAL JURISDICTIONAL REQUIREMENTS. SHEET NUMBER
m Treasure cuss[ stl rcEe 10. CITY/COUNTY ORDINANCES. T 1
I,le,Wional
} ., .. Airportaod
REV DATE DESCRIPTION
1. FOR THE PURPOSES OF THESE CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: 1. THE APPROPRIATE UTILITY LOCATING SERVICES SHALL BE CONTACTED PRIOR TO THE START OF CONSTRUCTION IN ORDER TO VERIFY THE A 4/6/21 PRELIMINARY
OWNER - T-MOBILE USA EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. B 4/9/21 REVISED
2. THE INSTALLATION OF NEW UTILITIES SHALL BE COORDINATED WITH LOCAL AUTHORITIES. C 4/16/21 REVISED
ENGINEER - APX ENGINEERING GROUP, LLC. 0 5/7/21 FOR PERMIT
CONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) 3. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT
ALL TIMES. WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SUCH UTILITIES SHALL BE RELOCATED AS DIRECTED BY THE
2. PRIOR TO SUBMITTING HIS BID, THE CONTRACTOR SHALL VISIT THE JOB SITE IN ORDER TO (1) VERIFY ALL EXISTING CONDITIONS, (2) CONSTRUCTION MANAGER. EXTREME CAUTION SHALL BE USED WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES.
CONFIRM WHETHER ALL DIMENSIONS ARE AS SHOWN ON THE PLANS AND (3) CONFIRM WHETHER THE WORK MAY BE ACCOMPLISHED AS
SHOWN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER. 4. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY.
3. A 20-FOOT HORIZONTAL CLEARANCE DISTANCE SHALL BE MAINTAINED FROM ALL EXISTING POWER LINES. 5. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES THAT INTERFERE WITH THE EXECUTION OF THE WORK SHALL
4. THE CONTRACTOR'S USE OF A CONSTRUCTION STAGING AREA SHALL BE COORDINATED WITH THE OWNER WELL IN ADVANCE OF THE BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS THAT WILL NOT INTERFERE WITH THE EXECUTION OF
THE WORK, SUBJECT TO THE APPROVAL OF THE LANDLORD AND/OR LOCAL UTILITIES. APX PROJECT NO.: 21-0270.13
CONSTRUCTION START DATE.
5. LABOR, MATERIAL, TOOLS, EQUIPMENT, TRANSPORTATION AND TEMPORARY POWER SERVICES NECESSARY FOR AND INCIDENTAL TO
6. DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION SHALL BE MINIMIZED. DRAWN BY: R. GARCIA
COMPLETION OF ALL WORK SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS AND/OR AS SPECIFIED HEREIN. LABOR AND MATERIALS 7• ANY AREAS OF THE CONSTRUCTION SITE DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL CHECKED BY: M. ABBEY
SHALL BE FURNISHED AS REQUIRED FOR COMPLETE SYSTEMS, INCLUDING ALL ELEMENTS OBVIOUSLY OR REASONABLY INCIDENTAL TO A BE GRADED TO A UNIFORM SLOPE. SUCH GRADING SHALL CAUSE SURFACE WATER TO FLOW AWAY FROM ANY EQUIPMENT SHELTER AND THIS DRAWING IS COPYRIGHTED AND IS
COMPLETE INSTALLATION, WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS. TOWER AREAS AND THE SOIL SHALL BE STABILIZED TO PREVENT EROSION. EROSION CONTROL MEASURES,IF REQUIRED DURING THE SOLE PROPERTY OF THE OWNER. IT
CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. IS PRODUCED SOLELY FOR USE BY THE
6. FOR TASKS REQUIRED TO BE PERFORMED BUT NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS, THE CONTRACTOR OWNER AND ITS AFFILIATES.
SHALL NOT START WORK ON SUCH TASKS WITHOUT HAVING RECEIVED WRITTEN AUTHORIZATION FROM THE CONSTRUCTION MANAGER TO 8. THE SUB-GRADE SHALL BE COMPACTED AND BROUGHT TO A UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. REPRODUCTION OR USE of THIS DRAWING
THEIN
PROCEED. AITDISOFORBDDENOWITHTOUT ION THHETAINED WR17FEN
7. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS OTHERWISE INDICATED 9• BACKFILL SHALL CONSIST OF CLEAN SAND FILL APPROVED FOR USE BY THE ENGINEER. NO UNAPPROVED MATERIAL WILL BE ALLOWED. PERMISSION OF THE OWNER.
CLEAN SAND FILL SHALL BE FREE OF ALL ROOTS, BOULDERS, OR OTHER DELETERIOUS MATERIAL.
BY DIMENSIONS OR DETAILS. EXACT EQUIPMENT LOCATIONS MAY BE MODIFIED AS REQUIRED BY ACTUAL FIELD CONDITIONS. IF THE
SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, CONTRACTOR SHALL PROPOSE AN ALTERNATIVE 10. THE CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EQUAL TO OR BETTER CONDITION THAN ORIGINAL.
INSTALLATION FOR APPROVAL BY THE ENGINEER AND THE CONSTRUCTION MANAGER.
8. THE CONTRACTOR SHALL OBTAIN, PAY FOR AND DELIVER ALL REQUIRED PERMITS, CERTIFICATES OF INSPECTION, INCLUDING UTILITY 11. SITE SIGNAGE SHALL BE PROVIDED IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR SUCH SIGNAGE AS MAY BE CONTAINED IN
THESE DRAWINGS.
CONNECTION FEES, ETC., REQUIRED BY THE AUTHORITIES HAVING JURISDICTION AND SHALL DELIVER SUCH DOCUMENTS TO THE OWNER
PRIOR TO FINAL ACCEPTANCE OF THE WORK. SITE WORK NOTES 3
9. THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED TO AREAS OF NEW CONSTRUCTION. ® -
10. ALL NECESSARY PROVISIONS SHALL BE MADE TO PROTECT EXISTING IMPROVEMENTS, LANDSCAPING, PAVING, CURBS, GALVANIZED ENG I N E E RI N G G R O U P
SURFACES, ETC, AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO SAME RESULTING FROM THE CONSTRUCTION WORK. 1. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE LATEST EDITION OF THE AISC "STEEL CONSTRUCTION MANUAL". 14471 MIRAMAR PARKWAY, SUITE 202
ALL DISTURBED AND DAMAGED AREAS SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR BETTER UPON COMPLETION OF ALL WORK MIRAMAR, FL 33027
2. MAMATERIAL: (9sa) �a4-15381s3a
TO THE SATISFACTION OF THE CONSTRUCTION MANAGER. A. ALL STRUCTURAL STEEL WF BEAMS SHALL BE ASTM A992 AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND
CERTIFICATE OF AUTHORIZATION 31948
11. THE FOLLOWING CLEANUP TASKS SHALL BE PERFORMED AS FOLLOWS: (1) ON A DAILY BASIS, KEEP THE GENERAL AREA CLEAN AND ASTM A153 STANDARDS.
2 UPON B. ALL STRUCTURAL PLATES, ANGLES, AND CHANNELS SHALL BE ASTM A36 AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM
HAZARD FREE, REMOVING ALL WASTE, DEBRIS AND TRASH FROM THE SITE AND DISPOSING OF SAME IN A LEGAL MANNER.
( ) A123 AND ASTM A153 STANDARDS, UNLESS NOTED OTHERWISE.
COMPLETION, LEAVE THE PREMISES IN A CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. C. ALL TS MEMBERS SHALL BE ASTM A500 GRADE B (Fy=46ksi), AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123
12. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE RESPECTIVE MANUFACTURER'S RECOMMENDATIONS EXCEPT AND ASTM A153 STANDARDS.
WHERE IT IS SPECIFICALLY INDICATED OTHERWISE IN THE CONTRACT DOCUMENTS OR WHERE LOCAL CODES OR REGULATIONS TAKE D. ALL STRUCTURAL PIPE MEMBERS SHALL BE ASTM A500 GRADE B (Fy=42ksi), AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH
ASTM A123 AND ASTM A153 STANDARDS, UNLESS NOTED OTHERWISE PRECEDENCE. E. ALL NON-STRUCTURAL PIPE MEMBERS SHALL BE ASTM A53 GRADE B, AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM T ■ .Mobile■
13. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND A123 AND ASTM A153 STANDARDS.
ORDINANCES. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL 2 DESIGN, FABRICATION, AND CONSTRUCTION OF ALL CONNECTIONS SHALL CONFORM TO AISC STEEL CONSTRUCTION MANUAL.
ORDERS OF ANY PUBLIC AUTHORITY HAVING JURISDICTION OVER THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS
SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AS WELL AS LOCAL AND 3. WELDING:
STATE CODES, ORDINANCES AND APPLICABLE REGULATIONS. A. ALL WELDS, WELDERS, AND WELD INSPECTIONS SHALL CONFORM TO THE REQUIREMENTS OF AWS D 1.1, LATEST REVISION.
14. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AT ALL TIMES, USING THE BEST SKILLS AND ATTENTION. HE SHALL BE B. ALL WELDS SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES.
SOLELY RESPONSIBLE FOR ALL OF THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR C. ALL STEEL SHALL BE SPRAY GALVANIZED AFTER WELDING.
COORDINATING ALL PORTIONS OF THE WORK, INCLUDING CONTACT AND COORDINATION WITH THE CONSTRUCTION MANAGER AND WITH THE 4. ALL BOLTS SHALL BE GALVANIZED W DIAMETER, A325-N, UNLESS NOTED OTHERWISE AND TIGHTENED TO A "SNUG TIGHT'CONDITION AS
OWNER'S AUTHORIZED REPRESENTATIVE. DEFINED BY AISC. SECURE NUT WITH LOCKING WASHER. THIS DOCUMENT HAS BEEN
15. WITHIN TEN (10) WORKING DAYS AFTER PROJECT COMPLETION, THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS-BUILT ELECTRONICALLY SIGNED AND SEALED
BY ELIEZER DIAZ, PE (#85219) ON
DRAWINGS, SWEEP TEST, CYLINDER TESTS, LIEN RELEASES, AND OTHER CLOSEOUT DOCUMENTATION AS REQUIRED BY THE OWNER. ALL 5. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36, UNLESS NOTED OTHERWISE. JUNE 23rd, 2021 USING A DIGITAL
SYSTEMS SHALL BE COMPLETELY ASSEMBLED, TESTED, ADJUSTED AND DEMONSTRATED TO BE READY FOR OPERATION PRIOR TO THE SIGNATURE IN ACCORDANCE WITH
OWNER'S ACCEPTANCE. 6. THE CONTRACTOR/STEEL FABRICATOR SHALL LOCATE ANY REINFORCEMENT IN THE STRUCTURAL MEMBERS IN SUCH A MANNER SO THAT A.C. 61G15-23.004, WITH A DIGITAL
THERE WILL NOT BE CONFLICT WITH THE REINFORCEMENT WHEN INSTALLING ANCHORS. THE ANCHORS SHALL BE INSTALLED PER THE ERTIFICATE ISSUED BY ENTRUST, INC.
MANUFACTURER'S INSTRUCTION. LEASE REFERENCE THE COVER PAGE
SITE WORK NOTES 1 TIITSVIEW PROPERTIETHEISNAPRINTEDD E COPIS
7. THE CONTRACTOR/STEEL FABRICATOR SHALL CONFORM TO THE MINIMUM EDGE DISTANCE REQUIREMENTS IN ACCORDANCE WITH THE AISC OF THIS DOCUMENT ARE NOT
MANUAL OF STEEL CONSTRUCTION. CONSIDERED SIGNED AND SEALED
AS OUTLINED BELOW, THE CONTRACTOR SHALL INSPECT THE T-MOBILE EQUIPMENT AREA AND ACCESS PATHS TO THE EQUIPMENT FOR OSHA AND THE SIGNATURE MUST BE
VIOLATIONS. VIOLATIONS SHALL BE CORRECTED. DISCREPANCIES OR QUESTIONS REGARDING THE OSHA SCOPE OF WORK SHALL BE DIRECTED TO 8. ALL STRUCTURAL STEEL SHALL BE FABRICATED TO FIT AT BOLTED CONNECTIONS WITHIN 1/16 INCH TOLERANCE. STRUCTURAL STEEL SHALL VERIFIED ON ANY ELECTRONIC COPIES
THE T-MOBILE FM. NOT BE FLAME CUT UNDER ANY CIRCUMSTANCES WITHOUT APPROVAL OF THE ENGINEER.
1. RF RADIATION SIGNS SHALL BE INSTALLED AT ROOFTOP DOORS AND EACH SECTOR. 9. THE CONTRACTOR/STEEL FABRICATOR SHALL CAP OR SEAL ALL PIPES AS REQUIRED TO PREVENT WATER INTRUSION.
2. HOLES IN A PLATFORM WALKING SURFACES SHALL BE COVERED AND SECURED WITH CARRIAGE BOLTS. 10. THE CONTRACTOR/STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO ANY STEEL FABRICATION. AT THE A2P0045B
3. INSTALL A NON-SLIP PATH LEADING TO THE T-MOBILE LEASE AREA. CONTRACTOR'S OPTION, FIELD SPLICES MAY BE USED FOR ERECTION PURPOSES. IF FIELD SPLICES ARE USED, THE SHOP DRAWINGS
4. HANDRAILS SHALL BE INSTALLED WITHIN 15' OF WORKING/WALKING SURFACES WHEN THE PARAPET OR THE EXPOSED WALKING EDGES SHALL INCLUDE ALL DETAILS FOR THE PROPOSED FIELD SPLICES. MICROWAVE
RAILINGS IS LESS THAN 42" ABOVE WALKING EDGE. 11. AT THE CONTRACTOR'S OPTION, SHOP WELDS MAY BE USED INSTEAD OF FIELD WELDS. SERVICE COMPANY
5. TRIP HAZARDS NEAR WORKING/WALKING SURFACES SHALL BE MARKED WITH HIGH VISIBILITY PAINT OR TAPE. 12. SUBMIT ORIGINAL SHOP DRAWINGS, INCLUDING COMPLETE DETAILS, SCHEDULES OF FABRICATION AND ASSEMBLY, PROCEDURES, AND
6. INSTALL A CROSSOVER STAIR WHEN OBSTRUCTIONS PREVENT A DIRECT WALKING PATH TO THE T-MOBILE LEASE AREA. DIAGRAMS. INCLUDE DETAILS OF CUTS, CONNECTIONS, CAMBER, HOLE, AND OTHER PERTINENT DATA. INDICATE WELDS BY STANDARD AWS 6189 N US-1
7. PLATFORM LADDERS SHALL HAVE A CHAIN AT THE TOP WHICH CAN BE SECURED TO PREVENT ACCIDENTAL FALLS. A2.1 AND A2.4 SYMBOLS, AND SHOW SIZE, LENGTH, AND TYPE OF WELD. PROVIDE SETTING DRAWINGS, TEMPLATES, AND DIRECTIONS FOR FORT PIERCE, FL 34951
8. OVERHEAD OBSTRUCTIONS NEAR WORKING AND WALKING SURFACES THAT REQUIRE A PERSON TO DUCK SHALL BE COVERED WITH HIGH INSTALLATION OF ANCHOR BOLTS AND OTHER ANCHORAGES TO BE INSTALLED AS WORK OF OTHERS' SECTIONS. SHEET NAME
VISIBILITY PAINT OR TAPE.
9. LIGHTS NEAR THE ROOFTOP DOOR AND OR LEASE AREA SHALL BE VERIFIED AND MADE FUNCTIONAL FOR AFTER-HOURS WORK. GENERAL NOTES
10. THERE SHOULD BE NO SCREW THAT CAUSE A PENETRATION INTO ANY CABINETS THAT ARE NOT FACTORY PROVIDED.
SHEET NUMBER
T-MOBILE STANDARD SAFETY COMPLIANCE NOTES 2 STRUCTURAL STEEL NOTES 4 T2
REV DATE DESCRIPTION
A 4/6/21 PRELIMINARY
B 4/9/21 REVISED
C 4/16/21 REVISED
0 5/7/21 FOR PERMIT
X X X X X X X X-1
x
x
x
EXISTING SPRINT
x UTILITY H-FRAME
x
EXISTING SPRINT APX PROJECT NO.: 21-0270.13
X EQUIPMENT CABINET DRAWN BY: R. GARCIA
(TYP. OF 2)
� CHECKED BY: M. ABBEY
x
1 2 THIS DRAWING IS COPYRIGHTED AND IS
(� x x x x x x X x EXISTING UTILITY POLE THE SOLE PROPERTY OF THE OWNER. IT
SOLELY FOR USE
WITH TRANSFORMER IS PRODUCEDOWNER AND ITS AFFILIATES.Y THE
W0000 REPRODUCTION OR USE OF THIS DRAWING
r AND/OR THE INFORMATION CONTAINED IN
I X X X X X x X X X X X X X X X X X X X X X X X X X X X X X X X X - IT IS FORBIDDEN WITHOUT THE WRITTEN
EXISTING 480'f I PERMISSION OF THE OWNER.
GUYED TOWER
EXISTING T-MOBILE
UTILITY H-FRAME I
I EXISTING T-MOBILE x
EQUIPMENT CABINET
(TYP. OF 2) I x ® -
I I ENGINEERING GROUP
x I 14471 MIRAMAR PARKWAY, SUITE 202
MIRAMAR, FL 33027
I I (954) 744-1538
I x I CERTIFICATE OF AUTHORIZATION 31948
I
l x- x J
x
T • •Mobile:
EXISTING A/C UNIT
x
EXISTING
x BUILDINGTHIS BEEN
j
ELECTRONICALLYMENT SIGN DAAND SEALED
BY ELIEZER DIAZ, PE (#85219) ON
JUNE 2 2021 USING A DIGITAL
SIG
EXISTING UTILITY SIGNATURE IN ACCORDANCE WITH
TRANSFORMER A.C. 61G15-23.004, WITH A DIGITAL
ERTIFICATE ISSUED BY ENTRUST, INC.
x LEASE REFERENCE THE COVER PAGE
TO VIEW THE SIGNATURE AND VERIFY
ITS PROPERTIES. PRINTED COPIES
x OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED
SIGNATUREAND THE x VERIFIED ON ANY ELECTRONIC COPIES
EXISTING VERIZON WIRELESS '
LP GENERATOR
x
x
A2P0045B
x MICROWAVE
EXISTING VERIZON WIRELESS O SERVICE COMPANY
500 GALLON LP TANK
6189 N US-1
EXISTING T-MOBILE 20kW FORT PIERCE, FL 34951
LP GENERATOR W/ 120 x x SHEET NAME
GALLON TANK BELLOW
x x
COMPOUND PLAN
x x
SHEET NUMBER
COMPOUND PLAN G 2' 1 C1
GRAPHIC SCALE
REV DATE DESCRIPTION
A 4/6/21 PRELIMINARY
B 4/9/21 REVISED
N C 4/16/21 REVISED
0 5/7/21 FOR PERMIT
APX PROJECT NO.: 21-0270.13
DRAWN BY: R. GARCIA
CHECKED BY: M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
♦:♦:♦:♦�♦:♦:♦:♦��� ►:.:♦:♦:♦:♦:♦�♦:♦:♦:♦:♦:��® THE SOLE PROPERTY OF THE OWNER.
IS PRODUCED SOLELY FOR USE BY THE
® ♦♦♦♦•♦♦ •♦♦♦♦♦•♦� ���•�����OWNOWN•�����o ® REPRODOWNER UCTION OR ITS USE OF AFFILIATES.
DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER. oo
r X X X X X X x x X X X r X X X X X X X X X X X x
EXISTING CHAIN LINK x EXISTING CHAIN LINK x
OPOSED 200A
FENCE EXISTING T—MOBILE FENCE TRMOBIILE DISCONNECT
x DISCONNECT TO BE x
EXISTING 480't GUYED REMOVED EXISTING 480't
TOWER GUYED TOWER
PROPOSED 200A
EXISTING T—MOBILE
EXISTING T—MOBILE T—MOBILE METER
i EXISTING T—MOBILE
CABLE BRIDGE � METER TO BE �♦® ♦ ♦ ENGINEERING GROUP
REMOVED EXISTING T—MOBILE . FIBER CABINET
6:114471 MIRAMAR PARKWAY, SUITE 202
EXISTING LEMOBILE BE x EXISTING T—MOBILE CABLE BRIDGE ����� . EXISTING T—MOBILE MIRAMAR, FL 33027
DIPLIXER TO BE FIBER CABINET UTILITY H—FRAME (954) 744-1538
REMOVED PROPOSED T—MOBILE �. ♦ CERTIFICATE OF AUTHORIZATION 31948
x EXISTING T—MOBILE HYBRID CABLE TO
EXISTING T—MOBILE FOLLOW EXISTING EXISTING T—MOBILE
RRU TO BE REMOVED PRO UTILITY H—FRAME CABLE ROUTE (TYP. O CABINET
�♦��♦����� ® a
(TYP. OF 3) OF 2) (APPROX. x �♦•♦ .� ���� ® � PROPOSED 4 EXISTING T—MOBILE LENGTH 215'f/65Mf) T—MOBILE C6
EXISTING T—MOBILE COVP
TELCO CABINET SERVICE LIGHT
- � LF �
TO BE REMOVED EXISTING T TO
PROPOSED T—MOBILE T Mobile
■
100A PPC TO BE 200A PPC ■ ■
EXISTING T—MOBILE REMOVED x —4„ — PROPOSED T—MOBILE
FCOA CABINET TO BE ® BATTERY CABINET 1
REMOVED x � � x ��� (ERICSSON B160' C6
EXISTING T—MOBILE SITE m \ m
SUPPORT CABINET TO x JI
i
BE REMOVED I PROPOSED T—MOBILE
� SITE SUPPORT CABINET
I ���. ���. (ERICSSON 6160) 1
������� ����������������������������������� ������������������������������� cs
x x THIS DOCUMENT HAS BEEN
EXISTING CABLE BRIDGE I —�.�♦ ������1�����I�������� ������������ EXISTING CABLE ����� �����.�����. ��� ����. ELECTRONICALLY SIGNED AND SEALED
(TYP.) x �� ��������������������� ��� � . BRIDGE (TYP.) �.♦�♦�.�♦�♦�.�♦ . . BY ELIEZER DIAZ, PE (#85219) ON
x
JUNE 23rd, 2021 USING A DIGITAL
����-�`�S� �♦ ��� E WITH
SC.N61 G1R5-123 004, WITH CA DIGITAL
•`,� •�,� LEASE AR REFERENCE THEISSUED BYE COVERT I PAGE
EXISTING TO VIEW THE SIGNATURE AND VERIFY
BUILDING x ITS PROPERTIES. PRINTED COPIES
o o EXISTING OF THIS DOCUMENT ARE NOT
x— x— x— x— x— x x— x— x— x— x— x
BUILDING CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE
x x VERIFIED ON ANY ELECTRONIC COPIES
/ EXISTING / EXISTING
x BUILDING x BUILDING
I
A2P0045B
MICROWAVE
SERVICE COMPANY
6189 N US-1
FORT PIERCE, FL 34951
SHEET NAME
EQUIPMENT PLANS
SHEET NUMBER
EXISTING EQUIPMENT PLAN ° 5 1 PROPOSED EQUIPMENT PLAN 5' 2 C2
GRAPHIC SCALE GRAPHIC SCALE
f REV DATE DESCRIPTION
PROPOSED T-MOBILE A 4/6/21 PRELIMINARY
B
BATTERY CABINET 4/6/1 REVISED
4/
(ERICSSON B160) - PROPOSED T-MOBILE AREA /21 FOR PERMIT
0 REVISED
LIGHT (LIGHT—UP 0 5/7/21
#LG—ALV2-150W-27V-40K)
PROPOSED LIGHT MAST
(1X- STD, PIPE BY
PROPOSED T—MOBILE 6'-0" LONG) APX PROJECT NO.: 21-0270.13
SITE SUPPORT CABINET
(ERICSSON 6160) DRAWN BY: R. GARCIA
CHECKED BY: M. ABBEY
io THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE IT
PROPOSED LIGHT MAST ISPRODUCEDOPERTY SOLELYOFORHUSEWBY THE
(SITEPRO1 #ACP10K) OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
10'-0" (TYP, OF 2) AND/OR THE INFORMATION CONTAINED IN
(TO GRADE) m Z IT IS FORBIDDEN WITHOUT THE WRITTEN
I PERMISSION OF THE OWNER.
PROPOSED EXISTING POST
HILTI KWIK BOLTT 3 3 A
MID.)
e d
cl
a d'
d d a d
C
qa -d - d - d ENGINEERING GROUP
O d'
14471 MIRAMAR PARKWAY, SUITE 202
MIRAMAR, FL 33027
(954) 744-1538
EXISTING T-MOBILE
CERTIFICATE OF AUTHORIZATION 31948
CONCRETE EQUIPMENT a
PAD a 9 a
SSC/BATTERY CABINET CONNECTION DETAIL NTs 1 WORK LIGHT DETAIL NTs 2 (NOT USED) 3
T • -Mobile
THIS DOCUMENT HAS BEEN
ELECTRONICALLY SIGNED AND SEALED
BY ELIEZER DIAZ, PE (#85219) ON
JUNE 23rd, 2021 USING A DIGITAL
SIGNATURE IN ACCORDANCE WITH
.A.C. 61G15-23.004, WITH A DIGITAL
ERTIFICATE ISSUED BY ENTRUST, INC.
LEASE REFERENCE THE COVER PAGE
TO VIEW THE SIGNATURE AND VERIFY
ITS PROPERTIES. PRINTED COPIES
OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES
A2P0045B
MICROWAVE
SERVICE COMPANY
6189 N US-1
FORT PIERCE, FL 34951
SHEET NAME
DETAILS
SHEET NUMBER
(NOT USED) 4 (NOT USED) 5 (NOT USED) 6 CIS
A - GENERAL REV DATE DESCRIPTION
A - GENERAL A 4/6/21 PRELIMINARY
Al. INSTALLATION OF GROUNDING SYSTEM SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE AND WITH ALL BUILDING B 4/9/21 REVISED
Al. ALL ELECTRICAL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (EDITION ADOPTED BY LOCAL JURISDICTION) AND APPLICABLE LOCAL CODES OF AUTHORITIES HAVING JURISDICTION. C 4/16/21 REVISED
CODES. A2. GROUNDING CONDUCTORS SHALL BE #2 AWG TINNED SOLID BARE COPPER BELOW AND ABOVE GRADE, UNLESS OTHERWISE NOTED 0 5/7/21 FOR PERMIT
A2. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE. AND SHALL BE ROUTED IN A DOWNWARD PATH TOWARDS GROUND BARS.
A3. ALL ELECTRICAL EQUIPMENT AND ACCESSORIES SHALL BE U.L. APPROVED OR LISTED. A3. GROUNDING CONDUCTORS SHALL BE KEPT AS SHORT AND DIRECT AS POSSIBLE WITH MINIMUM BEND RADIUS OF 12 INCHES.
A4. ALL POWER WIRING SHALL BE STRANDED COPPER, TYPE THHN/THHW AND 90 DEGREES C RATED. A4. ALL BELOW GRADE CONNECTIONS SHALL BE CADWELD TYPE CONNECTIONS AND ALL CONNECTIONS TO EQUIPMENT AND GROUND
BARS SHALL BE 2-HOLE BRONZE COMPRESSION CONNECTORS UNLESS OTHERWISE NOTED.
A5. ALL POWER WIRING SHALL BE INSTALLED IN GALVANIZED RIGID STEEL CONDUIT, PVC, OR FLEXIBLE LIQUIDTIGHT CONDUIT, AS INDICATED.
A5. GROUNDING CONDUCTORS SHALL BE BONDED TO CABLE SUPPORTS, ANTENNA FRAMES, AND ANY SUPPORT FRAMES OR RACKS
A6. CONTRACTOR SHALL OBTAIN ALL PERMITS, PAY PERMIT FEES, AND SCHEDULE INSPECTIONS. USING EXOTHERMIC WELDS OR MECHANICAL CONNECTIONS. APX PROJECT NO.: 21-0270.13
A7. CONTRACTOR SHALL APPLY FOR ELECTRICAL SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS, SERVICE ROUTING, AND METER A6. CONTRACTOR SHALL PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS, STAINLESS STEEL DRAWN BY: R. GARCIA
SOCKET TYPE WITH LOCAL POWER COMPANY. HARDWARE SHALL BE USED THROUGHOUT.
CHECKED BY: M. ABBEY
A8. CONTRACTOR SHALL APPLY FOR TELEPHONE SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS AND SERVICE ROUTING WITH A7. GROUNDING CONDUCTORS EMBEDDED IN CONCRETE OR PENETRATING WALLS AND FLOORS SHALL BE ENCASED IN PVC CONDUIT. NO
TELEPHONE COMPANY. METALLIC CONDUIT SHALL BE USED FOR GROUNDING CONDUCTORS UNLESS REQUIRED BY LOCAL CODES OR OTHERWISE INDICATED THIS DRAWING IS COPYRIGHTED AND IS
ON DRAWINGS. CONTRACTOR SHALL SEAL AROUND ALL CONDUIT PENETRATIONS TO PREVENT MOISTURE PENETRATION AND VERMIN THE SOLE PROPERTY OF THE OWNER. IT
A9. PROVIDE ALL LABOR AND MATERIAL DESCRIBED ON THIS DRAWING, AND ALL ITEMS INCIDENTAL TO COMPLETING AND PRESENTING THIS PROJECT INFESTATION. IS PRODUCED SOLELY FOR USE BY THE
AS FULLY OPERATIONAL. OWNER AND ITS AFFILIATES.
A8. CONTRACTOR SHALL VERIFY EXACT CONDUIT ROUTING FOR GROUNDING CONDUCTORS WHERE APPLICABLE. REPRODucnoN OR USE of THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
Al 0. WHERE LONG POWER CABLE RUNS PREVAIL, CONTRACTOR SHALL CALCULATE THE VOLTAGE DROP AND SIZE WIRES AND CONDUIT ACCORDINGLY. IT IS FORBIDDEN WITHOUT THE WRITTEN
A9. DOUBLING OR STACKING OF ANY GROUNDING CONNECTIONS IS NOT ACCEPTABLE. PERMISSION OF THE OWNER.
Al 1. WHERE TRANSFORMER IS REQUIRED FOR ELECTRICAL SERVICE, TRANSFORMER SECONDARY SHALL BE GROUNDED PER N.E.C., ARTICLE 250-26.
B - PREPARATION
Al2. ALL ELECTRICAL DEVICES EXPOSED TO WEATHER SHALL BE OF RAINPROOF CONSTRUCTION AND SHALL REQUIRE WATER TIGHT CONDUIT HUBS.
B1. SURFACES: ALL CONNECTIONS SHALL BE MADE TO BARE METAL. ALL PAINTED SURFACES SHALL BE FIELD INSPECTED TO ENSURE
A13. RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANGES, SUBSTITUTIONS BETWEEN WORK AS SPECIFIED AND INSTALLED. RECORD CHANGES ON PROPER CONTACT. ALL GALVANIZED SURFACES ON WHICH GALVANIZING HAS BEEN REMOVED BY CUTTING, DRILLING, OR ANY OTHER
A CLEAN SET OF CONTRACT DOCUMENTS WHICH SHALL BE TURNED OVER TO THE CONSTRUCTION MANAGER UPON COMPLETION OF THE PROJECT. OPERATION SHALL BE RE-GALVANIZED IN ACCORDANCE WITH ASTM A780 USING "ZINC RICH" COATING AS MANUFACTURED BY ZRC
CHEMICAL PRODUCTS COMPANY (LOCATED IN QUINCY, MASSACHUSETTS), OR ACCEPTABLE EQUAL. NO WASHERS ARE ALLOWED
A14. GUARANTEE/WARRANTY: GUARANTEE INSTALLATION TO BE FREE OF DEFECTS, SHORTS, GROUNDS, ETC., FOR A PERIOD OF ONE YEAR. FURNISH BETWEEN ITEMS BEING GROUNDED. ALL CONNECTIONS ARE TO HAVE A NON-OXIDIZING AGENT ("COPPER SHIELD") APPLIED PRIOR
WARRANTY SO THE DEFECTIVE MATERIAL AND/OR WORKMANSHIP WILL BE REPAIRED/REPLACED IMMEDIATELY UPON NOTIFICATION AT NO COST TO TO INSTALLATION.
THE OWNER FOR PERIOD OF WARRANTY. ® -
B2. GROUND BAR: ALL COPPER GROUND BARS SHALL BE CLEANED, POLISHED AND ANON-OXIDIZING AGENT ("COPPER SHIELD")
A15. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. APPLIED. NO FINGER PRINTS OR DISCOLORED COPPER SHALL BE PERMITTED. E N G I N E E R I N G G R 0 U P
14471 MIRAMAR PARKWAY, SUITE 202
A16. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR RIGID PVC SCHEDULE 80 FOR T-MOBILE GROUNDING REQUIREMENTS MIRAMAR, FL 33027
LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. (954) 744-1538
T1. COAX CABLE OUTER CONDUCTORS (SHIELDS) SHALL BE GROUNDED USING COAX GROUNDING KITS AT A MINIMUM OF TWO POINTS, CERTIFICATE OF AUTHORIZATION 31948
A17. LIQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR INCLUDING AT ANTENNA AND AT MASTER GROUND BAR. THE COAXIAL CABLE SHALL NOT EXCEED 100 FEET BETWEEN GROUNDING
FLEXIBILITY IS NEEDED. KITS.
A18. WIREWAYS SHALL BE EPDXY-COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARD; SHALL BE PANDUIT TYPE E T2. COAX CABLE ENTERING A BUILDING SHALL BE GROUNDED WITH COAX GROUNDING KITS TO AN INSULATED COAX GROUND BAR
(OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. WHICH SHALL BE INSTALLED ON THE OUTSIDE FACE OF THE BUILDING, BELOW THE CABLE ENTRY PORTS.
A19. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPDXY-COATED SHEET STEEL, SHALL T3. WHEN COAX CABLES ENTER A BUILDING FROM A TOWER, THE COAX GROUND BAR AT THE BUILDING SHALL BE CONNECTED TO THE
MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. EXTERNAL GROUND RING USING #2 AWG BARE TINNED SOLID COPPER ISOLATED IN PVC CONDUIT. T Mobile w
A20. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY-COATED, OR NON-CORRODING; SHALL MEET OR EXCEED UL514A
AND NEMA OS 1; AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS.
A21. NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) INDOORS, OR
WEATHER PROTECTED (WP OR BETTER) OUTDOORS.
B - POWER CABLE AND SERVICE
B1. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRING TO BTS AND VERIFY EXACT CONDUIT ROUTING. RACEWAY SYSTEM MATERIALS AND DEVICES
FURNISHED SHALL BE IN ACCORDANCE WITH APPLICABLE STANDARDS OF ANSI, NEMA, AND UL. RACEWAY SYSTEM COMPONENTS SHALL BE
INSTALLED IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF THE N.E.C. THIS DOCUMENT HAS BEEN
ELECTRONICALLY SIGNED AND SEALED
B2. CONTRACTOR SHALL SEAL AROUND ALL CONDUIT PENETRATIONS THROUGH WALLS, FLOORS AND ROOFS TO PREVENT MOISTURE PENETRATION OR BY ELIEZER DIAZ, PE (#85219) ON
VERMIN INFESTATION. JUNE 23rd, 2021 USING A DIGITAL
SIGNATURE IN ACCORDANCE WITH
B3. CONDUCTORS RUNNING ALONG HORIZONTAL SURFACES (ROOF TOP OR SLAB) SHALL BE INSTALLED IN RIGID CONDUIT SUPPORTED ON SLEEPERS. A.C. 61G15-23.004, WITH A DIGITAL
ERTIFICATE ISSUED BY ENTRUST, INC.
B4. ALL VERTICAL RUNS OF POWER CABLE EXCEEDING 80 FEET IN LENGTH SHALL BE SUPPORTED PER N.E.C. ARTICLE 300 USING KELLEMS GRIPS PLEASE REFERENCE THE COVER PAGE
OR ACCEPTABLE EQUAL CABLE SUPPORT SYSTEM. TO VIEW THE SIGNATURE AND VERIFY
ITS PROPERTIES. PRINTED COPIES
B5. WHERE A SEPARATE ELECTRICAL SERVICE DROP IS ADDED, CONTRACTOR SHALL INSTALL PERMANENT SERVICE DISCONNECT OR GROUPING OF THIS DOCUMENT ARE NOT
THEREOF, DENOTING ALL OTHER SERVICE ENTRANCES, LOCATION OF EACH AND THE AREAS SERVED BY EACH. CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE
B6. WHERE ELECTRICAL POWER IS TO BE SUB-FED FROM AN EXISTING DISTRIBUTION SYSTEM, THE FOLLOWING SHALL APPLY: VERIFIED ON ANY ELECTRONIC COPIES
A) CONTRACTOR SHALL PERFORM LOAD TESTING TO DETERMINE MAXIMUM FEEDER DEMAND PER N.E.C. ARTICLE
220-87.
B) CONTRACTOR SHALL VERIFY WHETHER EXISTING FEEDER CAPACITY EXCEEDS VALUE CALCULATED PER N.E.C. ARTICLE 220-87.
C) EACH BRANCH CIRCUIT PROTECTIVE DEVICE SHALL HAVE SAME INTERRUPTING RATING AS EQUIPMENT SUPPLYING IT.
D) PREFERRED MEANS OF SUPPLY SHALL BE A BRANCH CIRCUIT PROTECTIVE DEVICE LOCATED IN EXISTING PANEL. A2POO45B
E) IF A BRANCH CIRCUIT PROTECTIVE DEVICE CANNOT BE OBTAINED OR SPACE IS NOT AVAILABLE, A BRANCH CIRCUIT MAY BE TAPPED FROM MICROWAVE
EXISTING FEEDER CONDUCTORS USING AN INSTALLED 2-POLE FUSED DISCONNECT AND METER BASE PER N.E.C. ARTICLE 240-21 WITH TEN
FOOT (10) MAXIMUM TAP CONDUCTORS. FUSED DISCONNECT SHALL BE LISTED SAME OR BETTER INTERRUPTING RATING AS EXISTING SOURCE SERVICE COMPANY
OF SUPPLY.
C - IDENTIFICATION 6189 N US-1
FORT PIERCE, FL 34951
Cl. LOCATE NAMEPLATE, MARKING, OR OTHER IDENTIFICATION MEANS ON OUTSIDE EQUIPMENT OR BOX FRONT COVERS. SHEET NAME
C2. PROVIDE NAMEPLATE ENGRAVED WITH EQUIPMENT DESIGNATION FOR EACH SAFETY SWITCH AND ALL OTHER ELECTRICAL CABINETS, ETC. ELECTRICAL AND
C3. DURING TRENCH BACK-FILLING FOR EACH UNDERGROUND ELECTRICAL, TELEPHONE, SIGNAL AND COMMUNICATIONS LINE, PROVIDE A CONTINUOUS
UNDERGROUND WARNING TAPE TWELVE INCHES BELOW FINISHED GRADE. GROUNDING NOTES
SHEET NUMBER
ELECTRICAL NOTES 1 GROUNDING NOTES 2 L E1
REV DATE DESCRIPTION
A 4/6/21 PRELIMINARY
B 4/9/21 REVISED
C 4/16/21 REVISED
0 5/7/21 FOR PERMIT
x
0 L x x x x EXISTING UTILITY POLE WITH TRANSFORMER
PROPOSED 2"0 CONDUIT FOR go (COORDINATE WITH FORT PIERCE UTILITY
POWER (COORDINATE WITH FORT COMPANY PRIOR TO START OF WORK)
PIERCE UTILITY COMPANY FOR
CONNECTION POINT) x x x x x x x x x x x x x x x x x x x x x x x x x x x
PROPOSED T-MOBILE APX PROJECT NO.: 21-0270.13
200A METER DRAWN BY: R. GARCIA
PROPOSED T-MOBILE CHECKED BY: M. ABBEY
200A DISCONNECT
►O� THIS DRAWING IS COPYRIGHTED AND IS
�•�•�•� �/ THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
x OWNER AND ITS AFFILIATES.
PROPOSED T-MOBILE ■ REPRODUCTION OR USE OF THIS DRAWING
200A PPC ,a; AND/OR THE INFORMATION CONTAINED IN
x IT IS FORBIDDEN WITHOUT THE WRITTEN
/ PERMISSION OF THE OWNER.
x /
x C
A
Gl
�C
� x— x
cl
C ENGINEERING GROUP
PROPOSED 2"0 CONDUIT FOR 14471 MIRAMAR PARKWAY, SUITE 202
POWER APPROX. 100' IN LENGTH MIRAMAR, 4 33027
( ) (954) 744-1538
x ILl
CERTIFICATE OF AUTHORIZATION 31948
PROPOSED 2"0 CONDUIT FOR
POWER (APPROX, 100' IN LENGTH)
IC
G1
c
T • •Mobile:
x 'n
� UupP
x
x
cm
DOCUMENT HAS BEEN
ELECTRONICALLY SIGNED AND SEALED
cm ELECTRONICALLY
ELIEZER DIAZ, PE (#85219) ON
JUNE 23rd, 2021 USING A DIGITAL
x I SIGNATURE IN ACCORDANCE WITH
.A.C. 61G15-23.004, WITH A DIGITAL
ERTIFICATE ISSUED BY ENTRUST, INC.
x PLEASE REFERENCE THE COVER PAGE
cm TO VIEW THE SIGNATURE AND VERIFY
cm
ITS PROPERTIES. PRINTED COPIES
OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED
x I AND THE SIGNATURE MUST BE
VERIFIED ON ANY ELECTRONIC COPIES
C
cm EXISTING T-MOBILE 20kW LP
GENERATOR WITH INTEGRATED ATS
II A2P0045B
x a, MICROWAVE
1. PROPOSED CONDUIT ROUTING IS SCHEMATIC ONLY, O SERVICE COMPANY
CONTRACTOR SHALL DETERMINE SUITABLE ROUTING
IN THE FIELD. x x
6189 N US-1
2. TERMINATION OF NEW CONDUITS AT CABINETS SHALL FORT PIERCE, FL 34951
BE COORDINATED WITH T-MOBILE FIELD MANAGER. x x SHEET NAME
3. PROPOSED CONDUIT SHALL BE GALVANIZED RIGID STEEL
APART FROM PORTION ENTERING EQUIPMENT CABINET, WHICH UTILITY ROUTING
SHALL BE FLEXIBLE LIQUID TIGHT CONDUIT. PLAN
4. ALL CONDUIT TO BE ROUTED DIRECTLY OFF PAD AND RUN
UNDERGROUND OR ATTACHED TO SIDE OF PAD. SHEET NUMBER
UTILITY ROUTING PLAN 5' °' 1 E2
GRAPHIC SCALE
REV DATE DESCRIPTION
A 4/6/21 PRELIMINARY
B 4/9/21 REVISED
x C 4/16/21 REVISED
1 0 5/7/21 FOR PERMIT
x
PROPOSED 2"0 CONDUIT FOR
POWER (SEE NOTES)
PROPOSED T-MOBILE 200A
DISCONNECT
PROPOSED T—MOBILE 200A PPC APX PROJECT NO.: 21-0270.13
PROPOSED 2"0 CONDOR FOR DRAWN BY: R. GARCIA
PROPOSED 2"0 CONDUIT POWER (SEE NOTES) CHECKED BY: M. ABBEY
FOR POWER (APPROX 100't THIS DRAWING IS COPYRIGHTED AND IS
IN LENGTH) (TYP. OF 2) PROPOSED T—MOBILE 200A METER THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
x PROPOSED 2"0 CONDOR FOR OWNER AND ITS AFFILIATES.
POWER REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
x IT IS FORBIDDEN WITHOUT THE WRITTEN
I UGP UGP —i 1 PERMISSION OF THE OWNER.
E2
UGP �- UGP UGP UGP UGP UGP UGP EXISTING T-MOBILE FIBER CABINET
x 0 O
din PROPOSED 2J¢"O CONDUIT
din FOR TELCO/AAV (SEE NOTES)
�X Ion ign — mn--' a
x PROPOSED T-MOBILE ® -
PROPOSED A2*0 CONDUIT SERVICE LIGHT E N G I N E E R I N G G R O U P
FOR POWER (SEE NOTES) x UGP PROPOSED X"O CONDUIT 14471 MIRAMAR PARKWAY, SUITE 202
FOR POWER (SEE NOTES) MIRAMAR, FL 33027
(954) 744-1538
PROPOSED CABLE CONDUIT CERTIFICATE OF AUTHORIZATION 31948
BATTERYFOR
AUX POWER (SEE NOTES)
x
PROPOSED T-MOBILE
x BATTERY CABINET
(ERICSSON 6160) T • -Mobile•
x
I
x
I PROPOSED ZV2"0 CONDUIT
FOR ALARM & TEMPERATURE
SENSOR (SEE NOTES)
PROPOSED T—MOBILE THIS DOCUMENT HAS BEEN
x SITE SUPPORT CABINET ELECTRONICALLY SIGNED AND SEALED
♦ (ERICSSON 6160) BE Y LI23 Ed 2021 USING A 6219) ON
♦ T �— — . AL
SIGNATURE
N R 1 ACCORDANCE C. 61 G15-23 004, WITH DIGITAL
x ♦♦ ERTIFICATE ISSUED BY ENTRUST, INC.
.♦♦ LEASE REFERENCE THE COVER PAGE
.♦♦ TO VIEW THE SIGNATURE AND VERIFY
.♦♦♦'♦♦ L ITS PROPERTIES. PRINTED COPIES THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED
x
AND THE SIGNATURE MUST BE
♦ VERIFIED ON ANY ELECTRONIC COPIES
,♦ ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ A2P0045B
NOTES: Sm♦ ♦♦♦♦♦♦♦♦♦♦x ♦♦♦♦♦♦♦♦♦ MICROWAVE
1. PROPOSED CONDUIT ROUTING IS SCHEMATIC ONLY, ♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦♦ SERVICE COMPANY
CONTRACTOR SHALL DETER INE SUITABLE ROUTING .♦IN THE FIELD. _ .♦♦..................♦ ........_
�. 'I�♦
2. TERMINATION OF NEW CONBi11TS Al CABINETS SHALL FORT PIERCE, FL 34951
BE COORDINATED WITH T-40BILE FIELD MANAGER. .'♦♦ ` SHEET NAME
3. PROPOSED CONDUIT SHALL BE GALVANIZED RIGID STEEL '♦♦ ♦`APART FROM PORTION EN UTILITY ROUTING
ING EQUIPMENT CABINET, WHICH '♦.♦.♦.♦.,
SHALL BE FLEXIBLE LIQUIDxTIGHT CONDUIT. PLAN
4. ALL CONDUIT TO BE ROUT�D DIRECTLY OFF PAD AND RUN
UNDERGROUND OR ATTACHED TO SIDE OF PAD. SHEET NUMBER
UTILITY ROUTING PLAN 2' E3
GRAPHIC SCALE
REV DATE DESCRIPTION
PROPOSED 3#3/0, 1#6G - 2-C A 4/6/21 PRELIMINARY
PROPOSED 200A, 120/24OV, 10 HEAVY B 4/9/21 REVISED
DUTY FUSIBLE DISCONNECT W/ 65kAIC C 4/16/21 REVISED
CLASS J CURRENT LIMITING 200A FUSES 0 5/7/21 FOR PERMIT
(SEE NOTE 1)
AFC PT 1 = 6,937A PROPOSED 3#3/0, 1#6G - 2"C
PROPOSED 200A RATED METER
FAULT CURRENT CALCULATIONS G
AVAILABLE FAULT CURRENT AT UTILITY FROM SOURCE M -
TRANSFORMER BASED ON FPUA AFC
LETTER DATED APRIL 23, 2021: 8,311A APX PROJECT NO.: 21-0270.13
F = (2)(4)(8.31 1) = 0.198 200A PRIMARY & DRAWN BY: R. GARCIA
(13.923)(240) PROPOSED 3#3/0 - 2"C SECONDARY MAIN CHECKED BY: M. ABBEY
BREAKER W/ WALKING
M = 1 = 0.834 PROPOSED 2G-3 4"C TO EXISTING BEAM INTERLOCK THIS DRAWING IS COPYRIGHTED AND IS
1+0.198 # / THE SOLE PROPERTY OF THE OWNER. IT
BURIED GROUND RING IS PRODUCED SOLELY FOR USE BY THE
2P-60A 1 P-15A OWNER AND ITS AFFILIATES.
1 = (8,311)(0.834) = 6,937A SURGE SUPPRESSOR GFl REPRODUCTION OR USE OF THIS DRAWING
EXISTING GENERATOR W/ INTEGRATED (PRE-WIRED AT FACTORY) PRE-WIRED AT FACTO AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
AFC PT 1 = 6,937A TRANSFER SWITCH (SEE NOTE 3) 2P-200A 1 P-20A PERMISSION OF THE OWNER.
SITE SUPPORT CABINET(SEE NOTE SERVICE LIGHT
5)
NOTES: cl
1. BOND NEUTRAL TO GROUND IN DISCONNECT.
200A, 120/240V 10 E N G I N E E R I N G GROUP
2. PROVIDE PERMANENT SIGN AT T-MOBILE'S 200A SERVICE DISCONNECT: "20kW ON-SITE OPTIONAL STANDBY GENERATOR LOCATED SOUTH OF LOAD CENTER WITH 24 14471 MIRAMAR PARK 33027
WAY, SUITE 202
COMPOUND" BREAKER POSITIONS M(954)Rica 1538
CERTIFICATE OF AUTHORIZATION 31948
3. FIELD VERIFY IF EXISTING GENERATOR INTEGRATED ATS IS RATED FOR 200A TO BE REUSED WITH NEW 200A INCOMING SERVICE. NOTIFY FOR IF PROPOSED POWER 200A
INTEGRATED ATS IS RATED FOR LESS THAN 200A. PROTECTION CABINET TO REPLACE
4. PROVIDE FIELD OR FACTORY MARKED ARC FLASH WARNING LABEL FOR NEW ELECTRICAL EQUIPMENT THAT ARE LIKELY TO REQUIRE EXAMINATION, EXISTING 200A PPC
ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED PER NEC 110.16.
5. PROPOSED 200A FOUR-POSITION CIRCUIT BREAKER; SQUARED #Q02200.
PROPOSED AC ONE-LINE DIAGRAM NTS 1 '1' ' 'Mobile'
PANEL NAME: T-MOBILE PANEL RATING 200 AMPS PHASE 1 X MCB RATING 200 AMP
LOCATION: H-FRAME 120/240 VOLTS WIRE 3 MAIN LUG ONLY AIC RATING: 1 OKA
CKT DESCRIPTION AMP WIRE GND COND COND GND WIRE AMP KVA DESCRIPTION CKT
NO. A B POLE POLE A B NO. THIS DOCUMENT HAS BEEN
ELECTRONICALLY SIGNED AND SEALED
1 0 15/1 0.18 - GFCI 2 BY ELIEZER DIAZ, PE (#85219) ON
SURGE SUPPRESSOR 60/2 " " JUNE 23rd, 2021 USING A DIGITAL
3 - 0 1/2" #12 #12 20/1 - 0.15 SERVICE LIGHT 4 SIGNATURE IN ACCORDANCE WITH
5 - SPACE 6 .A.C. 61G15-23.004, WITH A DIGITAL
13.7 _ ERTIFICATE ISSUED BY ENTRUST, INC.
7 - SPACE 8 TO�VIEWSE RTHERENCE THE COVER PAGE
SGNATURE AND VERIFY
SITE SUPPORT CABINET( ) 200/2 #3/0 #6 2 1/2"
_ ITS PROPERTIES. PRINTED COPIES
9 13.7 1 OF THIS DOCUMENT ARE NOT
11 - SPACE 12 CONSIDERED SIGNED AND SEALED
AND THE SIGNATURE MUST BE
13 SPACE _ - SPACE 14 VERIFIED ON ANY ELECTRONIC COPIES
15 SPACE - - SPACE 16
13 SPACE _ - SPACE 18
19 SPACE - - SPACE 20
21 SPACE - - SPACE 22 A2POO45B
23 SPACE - - SPACE 24
MICROWAVE
SUB TOTAL KVA(CONT) 0 0 0 0 SUB TOTAL KVA(CONT) SERVICE COMPANY
SUB TOTAL KVA(NON-CONT) 13.7 13.71 0.18 0.15 SUB TOTAL KVA(NON-CONT)
TOTAL KVA 27.6 ( ) 114.9 TOTAL AMPS 6189 N US-1
NON-CONT+ 125% CONT. FORT PIERCE, FL 34951
PRE WIRED AT FACTORY SHEET NAME
PROPOSED 200A FOUR POSITION CIRCUIT BREAKER, SQUARE D#Q02200.
T-MOBILE SITE SUPPORT CABINET HAS POWER MONITORING AND LOAD SHEDDING CAPACITYTO MAINTAIN ELECTRICAL DETAILS
OUTPUT LOAD BELOW 20kW DURING OPERATION OF 20kW EMERGENCY GENERATOR
SHEET NUMBER
PROPOSED PANEL SCHEDULE 2 E4
REV DATE DESCRIPTION
EXISTING GROUND A 4/6/21 PRELIMINARY
BAR SOLID BARED B 4/9/21 REVISED
TINNED COPPER CONDUCTOR C 4/16/21 REVISED
•• W/ THERMOWELD 0 5/7/21 FOR PERMIT
PROPOSED ANTENNA WASHER
MOUNTING PIPE (TYP,)
0®o 0 0® %"x3/4" SS BOLT
APX PROJECT NO.: 21-0270.13
PROPOSED T—MOBILE °o o® °°o o®® DRAWN BY: R. GARCIA
ANTENNA (TYP.) RRUP4449 (TYP.)
® o
°0 ® ° CHECKED BY: I M. ABBEY
PROPOSED T—MOBILE m °0® o
� � THIS DRAWING IS COPYRIGHTED AND IS
RRU 4415 (TYP.) THE SOLE PROPERTY OF THE OWNER. IT
�JIII f 0 IS PRODUCED SOLELY FOR USE BY THE
I '"III I 3/g" WASHER OWNER AND ITS AFFILIATES.
III REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
PROPOSED T—MOBILE SS LOCK WASHER IT IS PFORBIDDEN ERMISSION OF THE
WRITTEN
TTHE OWNER.
I� RRU 4424 (TYP.) 3/s" SS NUT
TYPICAL GROUND BAR CONNECTION DETAIL NTS 2
A
I / a p
- -
FINISHED GRADE ENGINEERING GROUP
PROPOSED #J{2 AWG SOLID / / 14471 MIRAMAR PARKWAY, SUITE 202
1! / \ MIRAMAR, FL 33027
BARE TINNED COPPER (954) 744-1538
CONDUCTOR — PROPOSED T—MOBILE
�TMP6449 ANTENNA Ld rxc > ������/ CERTIFICATE OF AUTHORIZATION 31948
0 d���_
0\ �
2 EXISTING GROUND ooaBaoaoas / z m U
BAR (TYP.) �aoaaaa� o z WARNING TAPE
O /
N v)-i 2DD PSI T • -Mobile•�
Q FLOWABLE FILL
PROPOSED #6 AWG GREEN PROPOSED T—MOBILE
STRANDED COPPER SITE SUPPORT CABINET
CONDUCTOR (TYP.) (ERICSSON 6160) O O PVC CONDUITS
PROPOSED T—MOBILE 18" TRENCH OR
BATTERY CABINET AS REQUIRED BY
(ERICSSON 8160) POWER/TELEPHONE
COMPANY THIS DOCUMENT HAS BEEN
ELECTRONICALLY SIGNED AND SEALED
BY ELIEZER DIAZ, PE (#85219) ON
JUNE 23rd, 2021 USING A DIGITAL
TRENCH DETAIL NTS 3 SIGNATURE IN ACCORDANCE WITH
F.A.C. 61G15-23.004, WITH A DIGITAL
ERTIFICATE ISSUED BY ENTRUST, INC.
PLEASE REFERENCE THE COVER PAGE
TO VIEW THE SIGNATURE AND VERIFY
ITS PROPERTIES. PRINTED COPIES
OF THIS DOCUMENT ARE NOT
CONSIDERED SIGNED AND SEALED
NO SLAG OR AND THE SIGNATURE MUST BE
EXTERIOR GROUND DEFORMITIES ALLOWED ERIFIED ON ANY ELECTRONIC COPIES
RING, #2 SOLID,
BARE, THINNED
COPPER GROUNDING
CONDUCTOR
EXOTHERMIC WELD A2P0045B
(THERMOWELD
PARALOR QLEIL,, NOT) M I C R O WAV E
AWGRSOLIDEBARE / T—WELDS ALLOWED. SERVICE COMPANY
TINNED COPPER
CONDUCTOR (TYP,) / 6189 N US-1
EXISTING BURIED— FORT PIERCE, FL 34951
GROUND RING \ __ MINI SHEET NAME
PROPOSED CAD 1 / / 45MDE REES, TYPICAL
WELD (TYP,) - - - GROUNDING DETAILS
JUMPER, #2 SOLID, BARE, TINNED
�) COPPER GROUNDING CONDUCTOR
7 SHEET NUMBER
GROUNDING DIAGRAM (TYP.) NTS 1 WELD CONNECTION DETAIL NTS 4 E5