Atlantic Concrete Cutting & Breaking
2623 Hinda Road
Lake Park, FL 33403
2603 Rolyat Street
Fort Pierce, Florida
2104-0881
Respectfully,
PE # 81439 07/14/21
REVISED: PERMIT ADDED
June 30, 2021
CONTRACTOR:
JOB LOCATION:
PERMIT #:
To Whom it may concern,
Enclosed, please find the nuclear density test results performed on the Slab for the Metal Buildings at the above
referenced project.
Should you have any questions, please feel free to contact our office.
Bryan E. Dahlke, P.E. V.P. of Engineering
Proudly Serving Florida since 1990
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Email: atlconcut@gmail.com
July 14, 2021
Certified Women Owned Business - WBE
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB #:214903-1d/JM/bm
NUC #215
Nuc Model:MC-1DR-P
Nuc Serial #:MD80404215
2603 Rolyat Street
Fort Pierce, Florida
Slab for the Metal Buildings
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F)
PERCENT
COMPACTION
1 S.W.0" - 12"15D 100.2 104.1 96.3%
2 Center "15D 100.9 "96.9%
3 N.E."14D 99.6 "95.7%
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
Penetrometer readings indicate the
Degree of Compaction Meets
Minimum Requirement
7/14/2021
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
ITEM TESTED:
Disclaimer: Contractor is responsible to maintain
the tested area in the condition that KSM
completed the indicated passed compaction test.
KSM is not responsible if the tested area has been
altered from the approved inspected condition.
Soil Description:
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE
14.0%
PE # 81439
for Staked Foundation
104.1
TEST LOCATION
OF SAMPLE
JOB LOCATION:
Fine Tan Sand
CONTRACTOR:Atlantic Concrete Cutting & Breaking
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
REVISED: PERMIT ADDED July 14, 2021
DATE TESTED:June 30, 2021
In Place Moisture:
PERMIT #:2104-0881
Email: atlconcut@gmail.com
13.0%
Bryan E. Dahlke, P.E. V.P. of Engineering
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:June 30, 2021 KSM JOB # :214903-1d/JM/bm
PERMIT #:2104-0881
CONTRACTOR:Atlantic Concrete Cutting & Breaking
JOB LOCATION:2603 Rolyat Street
Fort Pierce, Florida
Soil Description:
Fine Tan Sand
Proctor Optimum Moisture:
13.0%
Proctor Max. Dry Density: P.C.F.
104.1
Bryan E. Dahlke, P.E. V.P. of Engineering
PE # 81439 7/14/2021
SOIL COMPACTION REPORT
ASTM D 1557
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Certified Women Owned Business - WBE
Proudly Serving Florida since 1990
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
99.0
100.0
101.0
102.0
103.0
104.0
105.0
106.0
8 9 10 11 12 13 14 15 16
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight