HomeMy WebLinkAboutAPPROVED stamped Plans I - 'r 1 ■
NTS
GL
UL
P.A -
"�I - NTS
u
PROPERTY LOCATION MAP PROPERTY --
LOCATION
DWELLING
�ILOCATION
■tit]\ �: ,{�
NTS
DWELLING
LOCATION Its
PROPERTY AERIAL LOCATION
I HEREBY CERTIFY THAT I HAVE REVIEWED DWELLING LOCATION
AND SUPERVISED THE ATTACHED DESIGN
AND FOUND IT TO BE IN COMPLIANCE WITH INDEX OF DRAWINGS
CHAPTER 3, SECTION R301.2.1 OF THE
2020 F.B.C. RESIDENTIAL, 7TH EDITION. DWG — � COVER SHEET AND PROPERTY LOCATION
This item has been electronically signed and sealed
ENGINEER'S SEAL by Ronald J.Leder Jr.,on the date adjacent to the
seal using a SHA authentication code.
\\���uuunuiiii
Digitally signed DWG - 2 PROPERTY AND DWELLING DATA
%%%% 3 - Lk�,D Ronald J by Ronald J Leder
DWG - 3 FLOOR PLAN AND REPAIR SCOPE DETAILS
-�--11 \cENs`� Leder J r Jr
Date: DWG - 4 REPAIR DETAILS SHEET
NO. 68160 13:28:44-04'00' DWG - 5 WINDOW PRESSURE WIND CALCULATIONS
* * * Printed copies of this document are not considered
signed and sealed and the SHA authentication
C.
must be verified on any electronic copies.
STATE OF PROPERTY OWNER: CONTRACTOR: ENGINEER: REVIEWING AGENCY: REV.DATE:
� � '• ; lV � REVISIONS PERMIT DRAWINGS FOR THELMA MOTEL,LLC
�j 0 ''• F� �P`,•' ��` DATE NO. DESCRIPTION MOHR DEVELOPMENT GROUP,INC. RONALD J.LEDER JR. 6585 N.US HIGHWAY 1,FORT PIERCE,FL 34946 5/24/21
O R �� THELMA MOTEL LLC JOSEPH M.MOHR ST.LUCIE COUNTY
/I �S' •,••••• ••' (j\ �\ FLORIDA PENO.68160
STEVE CARTWRIGHT PERMITTING/ZONING DEPT. SINGLE STORY DWELLING REPAIR PLANS
ONAL• N \\ 207 EASOT MAGNOLIA ST 4316 FOXGLEN LN. SHEET TITLE: SHEET NO.
\\ \ 465ROUSERD 7EASTM G OLIA TAMPA,FL.33624 OR PIERCE,
COVER SHEET AND
\\ FORT PIERCE,FL 34946 FORT PIERCE,FL.34982
PHONE:(772)473-1518 PHONE:(772)473-7355 PHONE: @G AIL.C87 PHONE:(772)462-1553
jmohr@mohrdevelopmentgroup.com RJLPALLC@GMAIL.COM PROPERTY LOCATION DWG-1
DWELLING DATA
Flnlshed Area:544 5F
Gross Sketched Area: 604 SF
Exterior Data
.............................. ..
Building Type: MFl1
Grade: y_
Year Built: 1940
PROPERTY DATA Effective Year, I94a
No.Units: 2
Property Identification Primary Nall: CS Stucco
Site Address:6585 N US HIGHWAY I Use Type:0900 Secondary Wall:
SecMbwn1P.artge:nW-W40E Account#:5905 Roof Cover. Tar&Gravel
Parcel ID: 1406-131-000I-000-9 Map lU: 14106N
Roof Structure: Flatl3hed
Jurisdiction:SaSnt Lucie County Zoning:Comm Geura
View:
Frame:
Ownership Story I leight; 1 Stoty
THELMA[N[7TEt LLC
465 Rouse RD Interior Data
Fort Pierce.FL M946
Bedrooms: 0
Legal Description Full Baths: z
6 3440 N 165 FTOF SW 1A OF NEE14 LYG BTWN TRNFK FEEDER RD r � � � Hall Baths: 0
AND US I MPDAF:BEG INT OF W"US j AND N LI OF SW 114 OF NE114,TH W 220,E FT TO E R/W TRNPK FEEDER RD.TH SLY ALO H R1W � Primary Int Wall: Drywall
I go FT.TII F 320 FI`To W R/W LDS 1.TH N ALG W WW 165 FT T[1 11013
Primary Floors: Tile-Ceramic
Avg IIgt/Floor: 0
Heal Type: Frcdllo(Air
Building design Wind Heat Fuel: FLEC
El ectTlc: MAXIMUM
peed AIC ion: I0(rro
Total Areas Heated%: I W/O
Finis;hed.'LfnderAfr(SF): 3.409 Int Sprinkler"/o;
0
Occupancy Category I II III & IV Grass Sketched Area(SF): 4,549 �.
Land Size(aches): 1,03
Speed 14Q 15� 16{1 Land Size(SF): 44.866
DWELLING
LOCATION w
ENGINEER'S SEAL
\\11111111111///////
NO. 68160
*
o STATE OF
'• •�•�� � REVISIONS PROPERTY OWNER: CONTRACTOR: ENGINEER: REVIEWING AGENCY: PERMIT DRAWINGS FOR THELMA MOTEL,LLC REV.DATE:
0i(�..
• F( �P •' ��� DATE NO. DESCRIPTION MOHR DEVELOPMENT GROUP,INC. RONALD J.LEDER JR. 6585 N.US HIGHWAY 1,FORT PIERCE,FL 34946 5/24/21
O R �� THELMA MOTEL LLC JOSEPH M.MOHR ST.LUCIE COUNTY
,I �S• (j\ �\ FLORIDA PE NO.68160
STEVE CARTWRIGHT PERMITTING/ZONING DEPT. SINGLE STORY DWELLING REPAIR PLANS
ONAL• N \\ 207 EASOT MAGNOLIA ST 4316 FOXGLEN LN. SHEET TITLE: SHEET NO.
�1\\ \ 465 ROUSE RD ARCADIM G OLIA TAMPA,FL.33624 OR PIERCE,
PROPERTY AND
// ////111111111\I \\ FORT PIERCE,FL 34946 FORT PIERCE,FL.34982
PHONE:(772)473-1518 PHONE:(772)473-7355 PHONE: @G AIL.C87 PHONE:(772)462-1553
jmohr@mohrdevelopmentgroup.com RJLPALLC@GMAIL.COM DWELLING DATA DWG-2
ol
DAMAGED AREA NARRATIVE: 34'-0"
17'-0" 17'-0"
1. DAMAGED ELEMENTS OF THE DWELLING STRUCTURE CAUSED BY lo21"x23
AN INTERNAL EXPLOSION INCLUDED CORNER LOCATIONS OF THE WINDOW
PERIMETER CMU BLOCK WALL, FLAT ROOF INTERFACE WITH 35",,37" to 0
CMU BLOCK WALL, WINDOW JAMB/SILL FRAMING, AND EXTERIOR/ WINDOW
INTERIOR WALL/CEILING STUCCO AND PAINT FINISHES. Qo Co jz:� I a
KI TCHEN
2. THE EXTENT OF DAMAGE TO THESE ELEMENTS WERE LIMITED TO QO Ln AREA RBA TH
OOM
DISPLACEMENT/DETACHMENT OF METAL ROOF/WOOD JOIST SYSTEM
FROM CMU BLOCK WALL, THE STRUCTURAL INTEGRITY OF THE - - -
TOP 3 COURSES OF 8"x8"x16" CMU BLOCK, AND SPORADIC I CD Q CD
CRACKING AT THE MORTAR JOINTS WITHIN PORTIONS OF THE Qo CEILING HT 9"-6"
WALL SURFACE FROM CORNER TO CORNER. ^3 CALL AREAS)
n o 00 FLOOR PLAN
3. FIRE DAMAGE WAS LIMITED TO THE EXIST. WOOD RAFTERS AND nz � BEDROOM SYMMETRICAL
"�'� LIVING ROOM
PLYWOOD SHEATHING AS PART OF THE CEILING/ROOF SYSTEM. 0-) 00
THERE WAS NO DISPLACEMENT OF THE PERIMETER CMU BLOCK DWELLING #1 DWELLING #2
WALL AT THE FOUNDATION LOCATION. 35'"x37"
WINDOW 32"x68"
DOOR
WORK SCOPE NARRATIVE:
17'-0" ij 1
LL 17'-0"
1. EXIST. DWELLING DISPOSITION AND DIMENSIONS HAVE BEEN 12'x5' EN K. CANOPY
DETERMINED BY SITE OBSERVATIONS AND FIELD VERIFICATION
MEASUREMENTS ONLY. THERE ARE NO KNOWN ARCHITECTURAL,
STRUCTURAL OR AS-BUILT PLANS/RECORDS. FLOOR PLAN
2. PERIMETER CMU BLOCK WALL REPAIR AT CORNER LOCATIONS NO SCALE
INCLUDED RE-ALIGNMENT TO PLUMB CONDITIONS, REINFORCE-
MENT OF CORNER INTERFACE, REPLACEMENT OF TOP 3 COURSES — — — —
OF 8"x8"x16" CMU BLOCK (SEE REPAIR DETAIL SHEET), AND cn ®I O 0 LEGEND:
SURFACE FINISHING OF STUCCO AND EXTERIOR PAINT. 4 I i0 Ao ELEC. RECEPTACLE OUTLET (4 REPLACED)
3. FLAT ROOF REPLACEMENT FOR 8'x16' DAMAGED AREA INCLUDED J I0 I 0
.-� / O � O2 ELEC. SWITCH (2 REPLACED)
DOUBLE 2"x6" PRESSURE TREATED JOISTS AT 12"o.c. WITH P.T. w �o I Oi O3 CEILING LIGHT FAN (� REPLACED)
3/4 PLYWOOD SHEATHING AND GALVANIZED METAL SHEETING Q o — —
(SEE REPAIR DETAIL SHEET). O O4 CEILING LIGHT (2 REPLACED)
9 5
4. INTERIOR SURFACE ELEMENTS UPGRADED PER LEGEND SUMMARY Q 35"x37" IMPACT WINDOW (3 REPLACED)0
INCLUDED 4 ELEC. RECEPTACLE OUTLETS, 2 ELEC. SWITCHES, w -i(If0 DWELLING y1 DWELLING #2 � 32"x68" FRONT DOOR
1 CEILING LIGHT FAN, 2 CEILING LIGHTS, 3 IMPACT WINDOWS, 5
CMU BLOCK WALL FRAMING FOR SHEETROCK INSTALLATION, AND 0 O7 9 RE—BUILT CENTER WALL
ASSOCIATED WALL AND CEILING PAINT FINISHES. of I �' Os CMU BLOCK WALL REPAIR LOCATIONS
®I O I Oi O O9 FLAT METAL ROOF REPLACEMENT LIMITS
ENGINEER'S SEAL —Tr Nd
\\11111111111/////// 1
% �:..LEOF 8'-0" REPAIR
`11"oP` �\c
NO. 68160 AREA LIMITS
E (WALL & ROOF)
- REPAIR SCOPE DETAILS
*
NO SCALE
-13
STATE OF
•�•�� REVISIONS PROPERTY OWNER: CONTRACTOR: ENGINEER: REVIEWING AGENCY: PERMIT DRAWINGS FOR THELMA MOTEL,LLC REV.DATE:
0i( •'• F( �P •' ��� DATE NO. DESCRIPTION MOHR DEVELOPMENT GROUP,INC. RONALD J.LEDER JR. 6585 N.US HIGHWAY 1,FORT PIERCE,FL 34946 5/24/21
O R �� THELMA MOTEL LLC JOSEPH M.MOHR ST.LUCIE COUNTY
�I �S• '••,••••• ••' (j\ �\ FLORIDA PE NO.68160
STEVE CARTWRIGHT PERMITTING/ZONING DEPT. SINGLE STORY DWELLING REPAIR PLANS
ONAL• N \\`` 207 EASOT MAGNOLIA ST 4316 FOXGLEN LN. SHEET TITLE: SHEET NO.
// 1\\ 465ROUSERD ARCADIM G 34266 23R PIERCE,
AVENUE FLOOR PLAN AND
/// �//111111111\I \\ ` FORT PIERCE,FL 34946 TAMPA,FL.33624 FORT PIERCE,FL.34982
PHONE:(772)473-1518 PHONE:(772)473-7355 PHONE:(813)455-6787 PHONE:(772)462-1553
jmohr@mohrdevelopmentgroup.com( 72)47 -7355p.com RJLPALLC@GMAIL.COM REPAIR SCOPE DETAILS DWG-3
16'-0" EAST WALL
#5 RE-BAR INSTALLED FULL DEPTH @ EVERY FILLED EXIST. METAL 8'-0"
CELL WITHIN WALL CORNER REPAIR LOCATIONS ROOF
ROOF DRIP
Qf EDGE LINE
D - Fm7
RAFTER HANGER, 2 EACH
r SIDE (SEE NOTE 2)
z z
PERIMETER 8" CMU
BLOCK WALL (TYP)
2"d' P.T. PERIMETER
J �
Lj
m m Co I TOP PLATE (3 SIDES)
co u� (-D I FLAT ROOF REPLACEMENT (P.T. 3/4" PLYWOOD
w w w I I SHEATHING W/ GALVANIZED METAL SHEETING)
„ EXISTING 35"x37" _ I I ( LL
SEE NOTE CENTER A1)
9 -0 (EAST WALL) WINDOW OPENING (TYP.) Q o
5'-0" (NORTH/ SEE PLAN SHEET #3 3: I I I I DBL. 2%6" P.T. JOISTS
SOUTH WALL) AND W.P. SHEET #5 -CD
I I I @ 12" ON CENTER
I I I I 16'x8' ROOF
D I I REPAIR LIMITS
0-) I I I 2%6" P.T. PERIMETER
TOP PLATE (3 SIDES)
I I I I PERIMETER 8" CMU
BLOCK WALL (TYP)
RAFTER HANGER, 2 EACH
L SIDE (SEE NOTE 2)
#5 RE-BAR INSTALLED FULL DEPTH @ EVERY FILLED - - - ROOF DRIP
CELL WITHIN WALL CORNER REPAIR LOCATIONS EXIST. 12" EDGE LINE
CONC. SLAB
CMU BLOCK WALL REPAIR DETAIL FLAT ROOF REPAIR DETAIL
NO SCALE NO SCALE
NOTES:
1. INSTALL SIMPSON 'STRONG-TIE' 3-IN X 6-IN, 18-GAUGE TRIPLE ZINC FACE
MOUNT RAFTER HANGER EACH SIDE PER MANUFACTURER SPECIFICATIONS.
ENGINEER'S SEAL 2. INSTALL SIMPSON 'STRONG-TIE' 6-INCH, 18-GAUGE STEEL RAFTER
\ottilII��������� TIE (4 LOCATIONS EACH CROSSING) PER MANUFACTURER SPECIFICATIONS.
%\`�\\\\, J...L
NO. 68160
*
STATE OF
•�•�� REVISIONS PROPERTY OWNER: CONTRACTOR: ENGINEER: REVIEWING AGENCY: PERMIT DRAWINGS FOR THELMA MOTEL,LLC REV.DATE:
�i(�•'• F� QP` •' �`� DATE NO. DESCRIPTION MOHR DEVELOPMENT GROUP,INC. RONALD J.LEDER JR. 6585 N.US HIGHWAY 1,FORT PIERCE,FL 34946 5/24/21
O R �: THELMA MOTEL LLC JOSEPH M.MOHR ST.LUCIE COUNTY
�I �S• '••,••••• ••' �j\ �\ FLORIDA PE NO.68160
STEVE CARTWRIGHT PERMITTING/ZONING DEPT. SINGLE STORY DWELLING REPAIR PLANS
ONAL \\` 465 ROUSE RD 207 EAST MAGNOLIA ST 2300 VIRGINIA AVENUE SHEET TITLE: SHEET NO.
S/ � % \` FORT PIERCE,FL 34946 TAMPA4316 O,XFLL33624 FORT PIERCE,FL.34982
\\ PHONE:(772)473-1518 PARCADIA,FL.342 55 PHONE:(813)455-6787 PHONE:(772)462-1553 REPAIR DETAILS SHEET DWG-4
\ RJLPALLC@GMAIL.COM
jmohr@mohrdevelopmentgroup.com
DESIGN CRITERIA:
Applicable Codes,Regulations,and Standards
1. The 7th Edition(2020)Florida Building Code,specifically
Chapter 16 Structural Design,Chapter 20 Aluminum,and Chapter 23
Wood.
2. ASCE 7-10.
Wind Loads
1. Building Occupancy Category,Paragraph 1604.5 and Table
1604.5: Risk Category 3. OPENING SCHEDULE
2. Basic Wind Speed,Table 1609C,State of Florida Debris Region
&Basic Wind Speed,Paragraph 1609.3.1 and Table 1609.3.1
Equivalent Basic Wind Speed:VuLr=170 MPH,VASD=131 MPH MARK SIZE (W%H") MANUFACTURER SERIES # APPROVALS DESIGN PRESSURES ALLOWABLE PRESSURES
3. Exposure Category,Paragraph 1609.4.3: C
zh 35" x 37" JELD—WEN W&D BUILDERS VINYL (V-2500) SH FL14104.8 +38.1/-51.1 PSF +50.0/-55.0 PSF
Scope of Work:
Replacement of(3)Glass Windows(east dwelling). Z4� 35" x 37" JELD—WEN W&D BUILDERS VINYL (V-2500) SH FL14104.8 +38.1/-51.1 PSF +50.0/-55.0 PSF
1. Windows not within 3 feet from corners.
35" x 37" JELD—WEN W&D BUILDERS VINYL (V-2500) SH FL14104.8 +38.1/-51.1 PSF +50.0/-55.0 PSF
Builder/Permit Application is to provide Florida Product Approvals
meeting required design pressures.
34'-0"
35" x 37"
HEADER STRAP
EQUAL TO
HUGHES HLSTA 24
C1260. UPLIFT)
0 ;&"0.C. �2 T-6" HEIGHT
C2)-2x4 srp,�2 72-1/2" 2-2X4 SrP912
STUD HURRICRNE
ANCHOR EQUAL MAX.
D T HC20 O
❑ HUGHES
�I... UPLIFT) XX4 IPf2 I DWELLING # 1 DWELLING #2
P Q0
2— X45
35" x 37" D
TYPICAL DOOR FRAMING TYPICAL WINDOW FRAMING
WINDOW FRAMING DETAIL
N TS
ENGINEER'S SEAL A
0INluuuu/i1.� 35" x 37"
N`` J...L
NO. 68160 5
STATE OF ' �
G(j REVISIONS PROPERTY OWNER: CONTRACTOR: ENGINEER: REVIEWING AGENCY: PERMIT DRAWINGS FOR THELMA MOTEL,LLC REV.DATE:
0 P R\OP *� `��� DATE NO. DESCRIPTION MOHR DEVELOPMENT GROUP,INC. RONALD J.LEDER JR. 6585 N.US HIGHWAY 1,FORT PIERCE,FL 34946 5/24/21
THELMA MOTEL LLC JOSEPH M.MOHR ST.LUCIE COUNTY
C, ��� STEVE CARTWRIGHT LIC.NO.CGC1514901 FLORIDA PE N0.68160 PERMITTING/ZONING DEFT. SINGLE STORY DWELLING REPAIR PLANS
•�N ��� VE ROUSE RD 207 EAST MAGNOLIA ST 4316 FOXGLEN LN. 2300 VIRGINIA AVENUE SHEET TITLERCE,FL.34 : SHEET NO.
ONAL � FORT PIERCE,FL 34946 ARCADIA,FL.34266 PHONETAMP(813)455-6787 PHONEA,FL.33624 FORT E(772)4621553 WINDOW PRESSURE
�/111111111111 982
PHONE:(772)473-1518 PHONE:(772)473-7355 DWG-5
jmohr@mohrdevelopmentgroup.com RJLPALLC@GMAIL.COM WIND CALCULATIONS