HomeMy WebLinkAboutAPPROVED Project Information RECEIVED Project Name: THELMA MOTEL MAY-2.6.2021 Project Location: 6585 N. US HIGHWAY 1, FT. PIERCE, FL 34946 Date: July 22, 2020 Perstttt_ncte De cp�artment Wind Speed (Vu,o: 170 mph Exposure Category: 0 Wind Speed (Vasd): 132 mph Building dimensions (rectangular,footprint): Length (ft): 12.5 Width-(ft): 33.5 Width of End Zone (Zone 5):F3 ft Mean Roof Height: 9.5 (MRH) REQUIRED DESIGN PRESSURES ASD PRESSURES PER ASCE7-10 Dimensions (ft) AREA Positive Negative Pressures ID# Opening Description Width Height (sgft) (4&5) Zone 4 Zone 5 1 BUILDERS VINYL(V-2500) SH 2.92 3.08 9.0 38.1 -41.0 -51.1 2 BUILDERS VINYL(V-2500) SH 2.92 3.08 9.0 38.1 -41.0 -51.1 3 BUILDERS VINYL(V-2500) SH 2.92 3.08 9.0 38.1 -41.0 -51.1 I Ae. o A OF �� �ONAL ��NG`````` d ` LITC Hazards by Location Search Information l 1 r0 ; seAL-rAuseum Address: N US Hwy 1,Fort Pismo,FL,USA ® ' t 4 �: I -It -Ft'P,Ierce lnldt Coordinates: 27.459249,-80.3286116 _ _ _,r �4!u- '4 State Pailk 12111 Elevation: 12 it Tlmestamp: 2020-07-22T07:31:05.580Z Hazard Type: Wind l eo Fort Pierce Goo le H ASCE 7.16 ASCE 7-10 MRI 10-Year ......._--------- 88 mph MR[10-Year ...._.......... .......... 88 mph MRI25-Year _._..__----------......-......------- 106 mph MRI25-Year ----_-_- --------- ............. 106 mph MRI50-Year -------------------------------------- 119 mph MRI50-Year _.__--. 119 mph MRI100-Year ___..........____________________ A 130 mph MRI100-Year -------------------------_-_----- A 130 mph You are In a wind-borne debris region If you are also within 1 You are In a wind-borne debris region If you are also within 1 mile of the coastal mean high water line. mile of the coastal mean high water line. Risk Category I ..........._•--------------------- 147 mph Risk Category I ____--__. _ 147 mph Risk Categoryl1 ------------------------------- A 159 mph Risk Categoryll ---...__--------_-._.---------- A 159 mph You are in a wind-borne debris region. You are In a wind-borne debris region. Risk Category III .............................. A 170 mph Risk Category III-IV ........................--. A 170 mph If the structure under consideration is a healthcare facility and If the structure under consideration is a healthcare facility and you are also within 1 mile of the coastal mean high water line, you are also within 1 mile of the coastal mean high water line, you are in a wind-bome debris region.If other occupancy,use you are In a wind-borne debris region.If other occupancy,use ' the Risk Category II basic wind speed contours to determine if the Risk Category II basic wind speed contours to determine If you are in a wind-borne debris region. you are in a wind-borne debris region. Risk Category IV _______............ A 182 mph You are in a wind-borne debris region. ASCE 7-05 ASCE7-05 Wind Speed______________________ A 140 mph You are In a wind-borne debris region. The results Indicated here DO NOT reflect any state or local amendments to the values or any delineation lines made during the building code adoption process.Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are interpolated from data provided In ASCE 7 and rounded up to the nearest whole Integer.Per ASCE 7,Islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area—in some cases,this website will extrapolate past the last wind speed contour and therefore,provide a wind speed that Is slightly higher.NOTE: For queries near wind-borne debris region boundaries,the resulting determination is sensitive to rounding which may affect whether or not it Is considered to be within a wind-borne debris region. Mountainous terrain,gorges,ocean promontories,and special wind regions shall be examined for unusual wind conditions. , While the Information presented on this website Is believed to be correct,ATC and Its sponsors and contributors assume no responsibility or liability for its accuracy.The material presented In the report should not be used or relied upon for any specific application without competent examination and verification of Its accuracy,suitability and applicability by engineers or other licensed professionals.ATC does not intend that the use of this information replace the sound Judgment of such competent professionals,having experience and knowledge In the field of practice,nor to substitute for the standard of care required of such professionals in Interpreting and applying the results of the report provided by this website.Users of the Information from this website assume all liability arising from such use.Use of the output of this website does not Imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by Iatitudellongitude location In the report. \I1�11111�1 ��''''''''' �. �•