Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutTrussREFER TO
PACK FOR
CCNNECITON.
14
1'
r-r
TYPICAL 7' SETBA
CORNERSET LABEL
AND SPACING
M j&ka;t. Aod-j rs&,,,
F-(, C-L c— AIL-© o 0 1, a 6—
MGM
MULTI -PLY GIRDER CUNNECTMK
ALL PLIES SHALL BE FASTEND TCGETHER (BOLTS, NAILS, MID IIR SCREWS)
PRIER TD INSTALATIN AND BEFORE ANY LOADS ARE APPLIED. PER THE
SUPPLIED ENGINEERING SHEETS
Nam
ID NOT CUR CR ALTER TRUSSES WITHOUT CONSENT 13e THIS OFFICE BACK
CHARGES VILL NOT BE ACCEPTED VITMUT PRIDR WRITTEN APPROVAL BY OUR
SERVICE DEPARTMENT AT CARPENTER C➢NTRAC M 13F AMERICA, INC.
877-293-9487
NOTFi
ALL BEARING WALLS MUST BE ADEQUATELY DESIGNED TG CARRY THE LDADS
IMPOSED BY THE TRUSS OR TRUSSES, AND MUST BE IIBLACE AND IN SERVICE
BU13RE THE TRUSSES ARE SET IN ORDER TO AVOID REPAIRS.
Labeled End Mark
Total Truss Quantity = 73
THIS IS A TRUSS PLACEMENT PLAN. ITS INTENDED TO AID IN THE INSTALLATION OF TRUSSES. ENGINEERED TRUSS DRAWINGS AND ARCHITECTURALS SUPERCEDE THIS DOCUMENT.
General Notes
1) *p fAt dom lm. US top dad p*p a m
to bs kaMW ¢am ida up.
2) =— to be Sngam MW Itdtea t4ltaaa
3) Mb� 9g b 2, O.C. tad® tr a y
4) ft Tntm Hda habUtb BMI-81 mmlrtlatdo8m
, a-. X-hecbg Il mW be pWW d a
madman Wooing I5 O.C. ttaam the ym, to
be rgettd d a mmfmtn d 20' bebtto —h
%bm� tlrw#rout 8n Arucbm
Plem CIS to -tlM, for arty odmBmd haft
ROOF LOADING SCHEDULE
TCLL = 20 PSF
BCU- 0 PSF
BCDL 10 PSF
TOTAL = 37 PSF
DURATION 1.25 %
WIND SPD/TYPE- 160
ENCLOSED
BLDG EXPOSURE = C
USAGE ce RESIDENTIAL CAT II
WIND IMPORTANCE FACTOR ee 1
UPLIFTS BASED ON= 9.2 PSF
DESIGN CRITERIA
FBC 2020
TPI 2014
Tmss member desiggnn & eonnccmr plates
am
dcsi6ncd for ASCE7-1E and maximum
finees from both components and claddings
and main wind tome resisting systems.
• These m"s have beev cored W ca- an
additional 109 psfn—o anent twnom chord live
load.
FLOOR LOADING SCHEDU
TCLL = PSF
TCDL = PSF
BCDL = PSF
TOTAL PSF
ROOF DESIGNED FOR
SHINGLE
AIL REACTIONS AND UPLIFTS
ARE SHOWN ON ENGINEERING
WALL KEY
8'-8-
® 0
OESCFBPn0N INTr. GATE
Iw oa ttn a IM1M @e0t1
M X-RW tad Vp Eu A olwm
M � VA 1�1� V eIRM
RE Rat nA W+C MI AAV1!
Men Im mn111 M Ip Van MMEV ■ MWA4
A6 C Ia1 ACIDMep OHO .wl UleM
m Ill Or eIlalD
M EMMAMUMM x tia ateO
M IM1C0 IiV. alRet {Ate.
LOAD# DESCRIPHON INIr. DATE
Im tor, uaf Aa1 fnvn
Irm MAR N6a.T W 7"=M
Y.e RV =t ® aVII IIAe/m
CARPENTER
CONTRACTORS
OF AMERICA
3900 AVENUE G. N W.
WINTER HAVEN FLDRIDA 33880
PHONE-(800) 959-8806
FAXt C663) 294-2488
BUILDER D.R. HORTON STATEWIDE
PROJECTCREEIME/3FH
MODEL 1672/ARIA/4EAB
CCA PROJ/MODEL ALT
7A5/ 320/167EC/
ALT DESC
OTC 9812 POTOMAC DR
LOT 124 BLOCK If
DESIGNER
PAGE
RFS
q
1
DATE
3 29 17
LAN
SCALE
1A4 "=1'
Builder:
Project:
Model/Building:
Lot Alt:
ENGINEERING PACKAGE
CR.
FA5/320 CREEKS IDE
Lot: �12� Block: E=_- -_�.
Unit:
Address:
JobNumber:N333978 i
Revision Date: -
New Load #:
CARPENTER CONTRACTORS OF AMERICA, INC
3900 AVENUE G. N.W.
WINTER MAVEN, FLORIDA 33880
PH (800) 959-8806 FAX (941) 294-7934
RJ01—
v
V
ALPINE
March 1.3,20.19 AN rTW COMPANY
Mr.. Bob Michaelis
G.ar06ht6r`Cdritr6ct6r"s of Am6ribk Inc'..
3900 Avenue G,. Northwest*
Winter He(Veh,.:FL 33880-5201
Re: Alternative lihstAllations.for 6sing"le ply' carried truss with a width Jess tha.r.) the -hanger width, and
wood. .blotking to: achieve fiAl design load: value -
for face-rriduhtod.'hgnger,.atta6ht6nt Wa, one ply
.supporting girder (Reference d6t'611 WA37-02)..
Pear Bob,
Fora single ply carried truss with awidth less than'the'har�gee. Width -you can irlstalfaa. prefabricated jack
scab .truss: -for woo.d.filler �16ckihgi. The chord : sh-res-:-c ...h ord.,grqcles, and 41pinetdhnd�btbr pwo,(s) to.
. .
. carried
be th6. same as the sIin6.16� ply' Jed truss. The prefabricate
d scab -truss (*):will have a..minimum
.Ien*gih of 48" a 'minim carried and will have a.. u.m.pitch-pf-51-12, The single ply car led Iruss shall have. a reaction of
3,.500# or les$. Attach orefEibricateid.jack:'scab:tr.uss. m ws'.'of 0A28'x3.W'GUn Nails at,2'
_..__ : O C,,.per:.row,;staggered 1" (See Figure 1 below) Please refer to the Simpson Sfrong="fie og.G-C
2019.. pqg!q 216 Figure for more information,
FjgUre 1
Fora single` pl" :, M " : that i requires wood blockin� to,*adhi " e �fU I design load VAIub for face -mounted
er re res ev.
hangers jy .gArq -attach one wood.. block to 'the back.. face the �jqgjp:�p -girderr with the, same size and
grade. -'e. single. ply girdOr. The -wood block [&both to 44�. Wdli thAC he wood
de..;�i8"the'botto-m.-6.hb�d.of'th t
blocking .extends toeach adj6'd6ntpanel oQihts;(w-bbs-.and bott
tndbot
omch6rdinter§ec.0ons):.-Altachwopd
block with 'two; . rows. ofb rx3.Q Gun Nails at610 b per row,. staggefed, 3. 0" applied to the
6760'Forum Wive Suite. 905, Orlando; Ft.32829 = {800) 52.1-9790-.(863):-4_2278685
-www.alpineitm,com
iu
ALPINE
.dm'". single plygirder%c% withan-additional (2Q) 0. 1-2-8N3-' , 0 �'Gun Nails at. -:each- panel ppirid appfiedtothe,
woodblo&-fabe (S6e Fig'062 bbI : oW )..P . Iea's6i rb'feftlo th'd.'S . irbo.�bb . Strong . Tie Catalog C 1
G, 2019., page 216,- floPre.-Vor thor& irif6ftnatibri.
OOUi&i:'
. .. ..... ... .... . .. .. ... .........
Theapplit:atiohofpr&.fabridatedj'ack'sc'abttu.§sfbrWijodfill'e't:blobki'ng':otwqqdbl'oc'in Iqachieve full.
design load. 'value for face;-m.ounted hangpi-q Must be -approved by the -hardware manufaci Urer.,
All edge -and end: disiarices, and spacing for all nail 6bnnedfibrig' Must be suffi'i6nt td OreV6ht-.8pIittihg of
0
"wood.
If I can.be. of any further.assistance,-o.r if you have any:qpestio.ns, please -give me a call.
Vilflatp H KH' kP.E.'.
Chief Engineer
Alpine -an I"M Com'pOny
Engin.eering.QOPEkrtm.erit
Odando,FL
6750 Forum DflV-e. Su- 1t6'306*,;O'fla'n'd6,.FL.32821 - (80Q)-521-9790 - (863) 422- - 8685
VIW..W . . aip,:ine;*-m.rh
ALPINE
AN"COMPANY
Ap
ril 26-:2019'
Mr. Bob Michaelis
Car-P enter Contractors ofAtnerica, Inc".
3900 Avenue 0; Northwest
Wintet Haven, FL 33880-620 1
DearBob,.
.R6' Stronobaick bridgiing',ion roof trusses.
I understand -there is §oM6 concern over our recommendations f6r.strbridback bridging on rooftru`
sses,
'Sirongback bridging for roof trusses is not.a.-requirement of:ANS.kTPI 2014 n of1he or is r: a re u. q irement
Building Component SafetyInformation .(BC.SI But stroogback bridgih ro6f trusses is
recommended,. by,,Carpenter Contractors .of. America '.:strorig0a6k.bridging serves..,thej
functions:.,wina, two.
- One, bridging aligns the bottom #pr.os -after they; are. set so.. they are uniform alon
g_ the ceiling
-wi - efli n'g`sprviqea i i y. lineand helos' ith c' bilk'
Twoibridging reduces relative deflection .6fadizidebt-ttUss6s:,
.. .. ......Strongback b(dging..d...oes: tiot-:0r6Vent or r6duc6-overall individual deflection, espedially any r66ftrUss...d... .g.. . ,
fleqtjn.n-pre. In 1W inch:
....
Si s. temporary.or pe �rnan rong0ack- bridging in roof trusses does 'not serve rve a bracing � and is not
.intended to . dj,§t6ui6- oi�.shtite'design jo . ads. - beNveen Trusses. Consequently, -n.p design . load's have`
been , n accounted for with thisAetail and continuous str6hgback'bridgiho -s�hdUld'not :bb:attaic'hed between-
cotrinion And irder 'trusses-.. The use -of strongback brioging% sh6fl notwith other- design
considerations as specified i*-the EMgihebr`0f Record cirthe. Building: Designer.
The outer ends othe stro ba
Mg. ck bridging shall be -attgched.to a: wall or anqtherzecure end..restraint; of
aPspecified:by the Engineer of Record or.thd Bu'i1ding.D6§jjh&r..
Sfr6figback- bridging shall. be ti. minimum of M norbiriai lumber. oriented with . th The d'eoth-vofticaf: .. Attach
immon nails nails at;. each int
with f6d :common. drsbctir.)g memb&. When -extending the
k bridging :strongbatk bridging overlap by at. a.minimpm pf two trusses. The.-Jocation� of. fbe�--.-�frong6ac -
Maybq. specified:t y`ffie Tru§s Manicifabtut.6r,. Engineer , of, Record, or Building Designer: Please* refer to
BCSI "Strangbacking'Provisions" or -to Alpine-:MOR-18kh.1014 detail for more. information. The graphic
shown (Figure.l) is n ilu 'raii'vepUrpose-on1g. M
6750 Form Drive:Suite 305, 006ndo, FL32821.- (800)52147K (863) 422"8685
*ww'..a10in6itO.Pom�
It
ALPINE
I -, v i.f, U L- t.: !I L L. lj V . I :. ') it
alit .T, s lot
Figure-J,
If bean be of any futihi§tassistance' or-Nyou -have :any questions; please; give. .me a c..all.
Williahi, H..,Knck- KE''.
Phief'.E.ng'knper
Alpine an jTW. .Company
Epginq6rin *136p6rtmie'fit
. .. 9
Qelan.dq, FL V82.1.
676.0. - Forum Drive Suite..366, Grlandd, FL 3282 - T-i (800). 521 - -9.790 - (863)-4224685
Www.., dpiriai .,CorT i
BR6GING TOGETHER
o.
each Individu k truss component, 'Bridging-,'
A.
truss, -strongbac brdqInq servesto reduce
' ATTAbHMENT ALTILWATIVtS
— '
AN nW4MMW
w4b
or Prorq
THe
enhancecl by. the.
----- by Alpine, -
|Foruddftlonu(
-- '�---= __,_.___
. | ~~'~`� ^'^~'~~~~
. °
'
6
^
o
o
a
.0; AU4
cm
47
in
rt PR
®rl
H OX
. . ...... . .... ....
Q13'. J. h 411:'
• OTIMA V u I.,
`7-7Vr MW I --RX B
21 VulN. 'Of .21 'k px P,
6, -,M�Ovl-4 Fill
'I'W- 14001-d N
38M I !pnV0SNW-- �40. QN, .
S'
-E);-NI8-0:,Jq,` 030N.- kq-00*381
Cracked or Broken
This drawing specifies repairs for a truss with broken chord
or web member.
This design Is valid onlyy for single ply trusses with 2x4 or
2x6 broken members, No More than one break per chord panel i,
and no more than two breaks per truss are allowed.
Contact the truss manufacturer for any repairs that do not
comply with this detail 1
(B) = Damaged area, 12' max length of damaged section
(L) = Minimum r1alLing distance on each side of damaged area (B)
(S) = Two 2x4 or two 2x6 side members, same size, grade, and
species as damaged member.- Applyy one scab per face,
Minimum side member lengths) _ (2)(L) + (B)
Scab member length (S) must be within the broken panel,
Nall Into 2x4 members using two (2) rows at 4' o,c., rows staggered,
Nall Into 2x6 members using three (3) rows at 4' oz., rows staggered,
Nail using 10d box or gun nails (0.12810', min) Into each side member.
The maximum permitted lumber grade for -use with this
detail Is limited to Visual grade 41 and MSR grade 165Of.
This repair detail may be used for broken connector plate at
mid -panel splices.
This repair de -tall may not be used for damaged chord or web
sections occurring within the connector plate area.
Broken chord may not support any tie -In loads,
S.
L L
4' o c
�Typlcai
+ o + o + o + o
O. + O + O + O +
St,
agger
Member-; Repair Detall
Load Duration = 0%
Member forces may be Increased for Duration of Load
Maximum Member Axial Force.
Member
Size
L
SPF-C
HF
DF-L
SYP
Web Only '
2x4
12'
620#
635#
730#
B004
Web Only '
2x4
18'
975#
1055#
1295#
1415#
Web or Chord
2x4
24
975#
1055#
1495#
1745#
Web or C4 ord
2x6
1465#
1585#
2245#1
2620#
Web or Chord
2x4
30'
1910#
1960#
2315#
2555#
Web or Chord
2x6
2230#
2365#
3125#
3575#
Web or Chord
.2x4
36,
24704
2530#
2930#
3210#
Web or Chord
2x6
3535#
3635#
4245#
4745#
Web or Chord
2x4
42'
2975#
3045#
3505#
3835#
Web or Chord
2x6
43954
4500#
5225#
5725#
Web or Chord
2x4
3460#
3540#
4070#
4445#
Web or Chord
2x6
5165#
5280#
6095#
6660#
• NIn6+un
L Oktanet
8
L
Ae
L �
llnlmun B \J`AC\
L IDlsiance 1/ 1
L
L
- Back Face 10d Box (0.128' x 3', min) Nallsl
o = Front Face 2x4 Member - Double Row Staggered
2x6 Member - Triple Row Staggered
Nail Spacing Detail L
,a.vARwNae■ Ilene AND ril 1. ALL Nntfs oN Tl1u nRAVINpI
UNWIIRTANTWw MUSH TNIS TRA1►➢16 TO ALL CCNTRM711 S INfJ_OM IM INSTALLERS,
REF MEMBER REPAIR
DATE 10/01/14
Trusses evIre swtrenr cart h Pabrleotlnp, handlhp, ship piu Installer and bradna. Refer to and
follow the latest v&U m of NCSI 0,Adeq Component Safety 1n?oraotlarny IN and SICA1 roe sale<y
proetkes prior -to performing ih►se functlona Installers ■1w.O provble .tenparory hraeNp per 7CS1,
palest noted otherwlas, too chord sholl have properly attached structural sheaThho and botton ellerd
DRWG REPCHRD1014
„s
S�P�
shall have a properly oiiaeFfed BCS celU+o. Loeatlons shorn for permanent lateral restraint or vrbs
�
shell hove lamch9 lnealled per I se 313. 117 or 330. os apppeahlh App1Y Plates to each Face
'the Jolni Dr}ats,wllessIatead oiMrvl
Q
L.�L.l.
�
of truss and posNkn os shorn aboveand on
Refah tO draflnps 1{aM2 for ttandard plate pefitlanr.
AN r1Wl7DMPANY
Alphe, a dNislon of ITV Ir Adlno Components Oro 1ne, shop net be respanslhle for o devla}ten Iron
tNs droelnp, any failure }o build the truss h can�ornancr with ANSI/TPI 1, or for I,ancL shlPDha,
'
hstallatbn 6 •trodlp of trusses.
A seal'on tYAs droaft or, 44over poppee Itaihp this drew4q, lndmits accePtnifce of prof sslomal
-rill rim rraponaR,Ait solaI for the deslr shorn Tr+ nAUbllty and use of iNs drawft
for any structure Is tha rsspafu>hAFty W tix Imu" Drslpmer per ANSMPI 1 Src 1.
,
I
SPACING 24,0' MAX
13389 WOW Me
Eadh CRY.110 83O45
For man Infornoilon see this Job's peneral notes page and ihtst Web slt►sl
ALPINE sys,al ItW,ean1 TPL wew,tpvat,oral =Ck vww,sbclndustryarp, IM wwYlccsafe,arg
v
Liurftber size and Orade-Minumm Requirements.
. 44a p1d, gr,
EF jw $2 D�p r be ar
A.: :CQr*Xer
-�fi -S02 , FA
Purfilng
r r..' 4.fe Wbeii%r
*
VF.n
Mdtarlp I
COUAR BEFVERY 7KRA
BOAR FAIR10F RAFTERS
L
01 vg kcING ING r. V-01. A 101 1
-0148M
bf.
I
TRUSS . 4
TRtfB.q-, UNDER VALLEY -FRAMING
VALLEY RAFTER.OR RIDGE
1p0Ieb,41-W*1dr.30 psf (M)gad-26 pSf (.TD) Ma(x,
4 tho-vailays br-sloopers
each Towstahtod ff.dm
work(..n . g' lri� t . d : WE W. Hd§ , nl&&d-�c itiiatcrlppije locations are
0 nOr. 16' ` ,011i ROQU. lrem ent.-Niotes
U6,tifiiFiioJr,1aji
4 10d'tcIi-491&-
de direaitty
C. tdf1`dj&
ciloole.,tdfofibi
'416d'toe,,nallt
teafbing
(*4)
sheatEtlOg
Mf%&1ta.Two.2X6 slcepen;.'
4 2 Sd tae-Wa I rs
5.
51dep6i W-truti,
4'2:6d taldiftils
31114 td&.rAUs,ea.ch slaeperjk tnjg
.6.
iti�
Mdge:bohrd.-rpof bldck
416dtoe-niills
'RF-C LID.F.OR PITCH .7.
Wtr.Wis-
43.6d.t6a*411s
z.
4rufflri to. (Typj.
.5.
Trizfm.:6166ifie
.10.
, -rruss-td:krjppti.
...n.
'Trun to dtf�.!Wp_
;.ARE USED) .13.
(;bllkrheahl tb-Taltdt
4 16dt0--nalls.
N0TE-,:1Q:(0AGeA.41C-oMM0N
NAIL§
'dqd:lu9iI;ar,1$j.:4ox or dozi�inpn -nails.
of 6"t.enii Hill( a OUL W1 a
bf �rlj�b(e,�a4:Mc� _,Nfirrc4w idol
f All I.mils:
Etfeels.aiQ, p jfs;j6nj as.t qfrqperlqumtierQf-npjIS are
cl o.rIdg6..vpw*d
rafter Ifs(eepers,are.nottloq
:
4n �a�ll
-Inttail,b(oIekinq
y height:14- -4p,all'
'Fla Nor;
.Maximum "n,rgbf height; 3,04pet 9
uNl0Ai;tjbtsd*6the 'Ise.
m -of AXE -7-10, 1:Bp rnp�h; CU610k4, 'ExP Ch
do"_v
lom T -.36 40 54 Rtp Nittv VAA-�w;(;
r.uRIPMt To.
c'
".
-w..u. itit V 04*0t,Y,
M1ZO 7 7 DAM j0/PjJ14
-ow604,FWN kQr,"= per: &
uee:.r.rigcea; other. ;% .-c ow,HC bL 0 .0 ri 0 DRWG V-ACNV-1801015
pw '8T
pez- AT L t bvr,. i
pLatR
Qr BT L1, 0 .0 0 0
T
&pdmy+jr C10. pe_ shu. pat. IM r.e:kq-jotR ew..' de 66
AN TrW
u' i
L
u.a
is /T I
-"A*o""Vii-m.I c=
"ohr17tppkaovs
a
Face -Mount Hangers - I -Joists, Clulam and SCL I F
........................................................................................................................................................................................................................................................................................................................................................................................................................
These products are available with additional corrosion protection. For more information, see p.15. Codes: See p.12 for Code Reference Key Chart.
ka
I7
• JURM
Size
(m j
lvjuuu1 -
No
21/z x 16
IUS2.56/16
MIU2.56/16
U314
HU316/HUC316
2Yzx18,
MIU2.56/t
---
.HU3161H,UC316 ,
21h x 20
MIU2.56/20
21hx 22,MIU2
to 26.
56/20
29/16 x 91/4
to 26
,rigid" ', .
T164 .
Dimensions
( n }"r
Min./
Pax
Fasteners
in, )
Allowable Loads
Catle
'Ref.,
Web -
o Stiff
Regd.�°
-
W
H,
B
`.Face -
Joist
DF/SP .
$pe'cies;Head'er�°Species
SPF/HF
Header
�Uplift
60),
Floor
jiOQj
.Snows
(115):'I
Roof
(125),
-
Floor
(100)
Snow.
j (115)
Roof"y
(125),
• -
25/e
16
2
Min.
(14) 0.148 x 3
-
'0
1,660
1,805
1,805
1,425
1,555
1,555
Max.
(16) 0.148 x 3
-
70
1,8115
1,805
1,805
11,555,
1,555
1,555
• -
29/rs
15'/s
21/z
-
(24) 0.162 x 31/z
(2) 0.148 x 11/z
230
3,455
3,920
4,045
2,970
3,370
3,480
• ✓
29/16
101h
2
-
(16) 0.162 x 31/z"
(6) 0.148 x 11h"
970
11,945
2,205
12,375
11,675
1,895
2,045
• ✓
29tis
141/a
21h
-
(20) 0.162 x 31/z
(8) 0.148 x 11h
1,515
2,975
3,360
3,610
2,565
2,895
3,110
IBC,
FL,
17Is.
'
1
2/z
;-
(26);0162 x31h
(2) 0.148 x11h
230
3.Z45�
4,045
4,045
3,220
3,480
3,480'
LA
✓
-2 4s,
i4?la' °
2'/z
-:-
- (20} 0' i62 x 31%z'1:
{8) OJ48 x i 1h=-' `
;1515:
2;975
3;360
3,610'
2 515,'2,895.
3,110
• -
29tis
19346
21h
-
(28) 0.162 x 3Yz
(2) 0.148 x 11/z
230
4,030
4,060
4,060
3,465
3,495
3,495
• ✓ "
29tis
77777
19'11s-
21/z,
°=
' `(28) 0162 x 31/2,
° "(2) 0.148 x 11h ''
. 230
4,030
4,060
4 060'
3,465
3;495
i 3,495.
29A6" wide joists use the same hangers as 21/z" wide joists and have the same bads.
HU210 2J HUG210-2,"
•- ✓
3%,I
8"hs<
21h;
MBX.
{18j 0.162-X 3Y2:
(10) 01148 X 3 `,
t...,-
2,680
3,U20,
3,LbO.
="L 30b
1605
"L,800
IBC,
'
MIU3.12/11
-
31/a
11'Ae
21/z
-
(20) 0.162 x 3Yz
(2) 0.148 x 11/z
230
2,880
3,135
3,135
2,475
5
2,69,695
2
FL,
3 x 11/a
HU212-2 / HUG212-2
• ✓
31/e
'109/is
21/z
Max.
(22) 0.162 x 31/i "
(10) 0.148 x 3`
1,795
3,275
3,695
3,970
2,820
3,180
3,425
LA
:r.'
'H11R,)Rfl9iHIIr.Q�r.7�.-.:
,.'
i�i
.. ii2/,
3r�;,�`:
r�dinia�Ya�
`
ngin1eRY-4
,-aF
IRM
4.n�nla�..
1.4 z;
1Anlz!
.r;
HUC3.25G16
...
' J4
�'.716
� �
Max.
1
(26) i3 I62 x 3 /z
(f 2) O':148 x 3. '�
1
. ,r
3,870
4,365
4,695`13
33013,755'
4,040]
31%glulatrt=
HUCO2104SDS
•
3Ya
9
3
-
.(12)1l4"x21h"SDS
(6)1/a'y 2'%z"SDS';
�,N
1,315
{°31'i
4.a1a
;3;600
3;�1(3
3,71!;)
FL
HGUS3.25110:
3%a
_ 85/a ,
, 4 ,
-
- (46) 4162 x 3Yzr
(16) O.j62 x 3'h.
4,095
9,100
.9,1Q0
9,100
7;825
°7;825
7,825
IBC,
urii"
I ti.
viu,
onvn;is;�iA .
An
A
HHUS46
I
I -
35/a
51/a
3
1 -
1 (14) 0.162 x 31/z
(6) 0.162 x 31/z
1,320
2,785
3,155
13,405
12,395
12,715
12,930
3Yz x 5Ya
HGUS46
•
-
35/a
47/is
4
-
(20) 0.162 x 31/2
(8) 0.162 x 31/z
2,155
4,360
4,885
5,230
3.750
4,200
4,500
HUS48 °`:._
_ -
3s/is{:
611iG
2'
.;=
(6)0.162x3'/z
(6}0;162�x3Yz _
1,320
1;595
1,815i1,960
1365(1;555I1;680
3Yzx.71/4�"
HHUS48°."
• !
- -.�3%
71/e
3
-
-(22)0.162x31/2,
(8)0162x31/2
,7,#0
4,210
4,77.0
5JW136151,4,095
4,415=
HGUS48
o
-
' 3,5(a
,7 s,'
°4,
-
,,(36),0.162,X 31h
(12} 0�76 Mx 3'h .'
3 235"
7,"A$0.'7,46Q-i"7,460
)' ,.415'
6,415
6,4151
IUS3.56/9.5
-
3%
91/z
2
-
(10) 0.148 x 3
-
70
1,185
1,345
1,455
1,020
1,160
1,250
MIU3.56/9
-
39/+s
8'Y1s
21/z
-
(16) 0.162 x 31h
(2) 0.148 x 11/z
210
2,305
2,615
2,820
11,980
2,245
2,425
U410
✓
39tis
8a/a
2
-
(14) 0.162 x 31/z
(6) 0.148 x 3
970
2,015
2,285
2,465
11,735
11,965
2,120
HUS410
-
39tis
811/%
2
-
(8) 0.162 x 31/z
(8) 0.162 x 31/z
2,990
2,125
2,420
2,615
1,820
12,070
2,240
HHUS410
-
35/e
9
3
-
(30) 0.162 x 31/2
(10) 0.162 x 31/z
3,565
5,635
6,380
6,445
4,845
15,486
5,545
31h x 91/z
HU410/HUC410
✓
39tis
8%
21/z
-
(36) 0.162 x 31/z
(12) 0.162 x 31/z
3,235
7,460
7,460
7,460
6,415
6,415
6.415
HUC0410-SDS
-
39/16
9
3
-
(12)1/4" x 2Yz" SDS
(6)1/4" x 2Yz" SDS
2,2635
4,500
4,500
4,500
3,240
3,24.0
3.240
HGUS410
-
35/a
9'/As
4
-
(46) 0.162 x 31h
(16) 0.162 x 3Yz
4,095
9,100
9,100
9,100
7,825
17,825
7,825
IBC,
LGU3.63-SDS
-
3%
8 to 30
41h
-
(16)1/4" x 21/z" SDS
(12)1/4" x 21/z" SDS
5,555
6,720
6,720
16,720
4,840
4,840
4,840
LA
MGU3.63-SDS
-
35/a
9'/4 to 30
41h
-
(24) 1.14" x 21h" SDS
(16)114" x 21/z" SDS
7,260
19,450
9,450
19,450
16,805
6,805
16,805
IUS3:56/1j$$ -�
o `-
3%
117/s'
2
==
'(12)4148x3;``-
-
7r
1,920°-1,615�
1,745Tg1220
1,390
°
1,485-
MIU3.56111
� ''-
3%
- .11'/a''
2?h,
=-
j20};O §2x 3Y
(2} 07,48 z 1 Yz
210.E
2;880
.3,135
3135
Z-475
2,695
2,695-
'U414 -
• •
.• ✓
r 39As
10 `.
2 "
'=
(16).0762 X 3Yz
(6) 0.14$ x 3 "'" .
9`0
2,305
2 615°
2 820
41;980
2,245
2,425`
HHUS410
-
35/s
9 ,_' ,
3
-
. (30} 0.162 x 3'h
(10) 6Atit X 31/z
,w,5F35"
5 635
6,380165,445
4 $45
5,486
5,5 45
HUS412
• •
=° '
39A6
10'%z
2
"�-
(10) 0162 x 31h
(10) 0.162 x 31/z
3'a35,
2,660
3,025
3 265
2;27512,590
-2,795
31hx 1f'/a
WU412/HUC412 ° ° ,
:-„
• •
A:39/ra
105/s3
21Iz.;
Mm.
(16)°0162'x 3'h
< (6).a.148 x-3:.
1135
2,380
2,6B5
2,890
�2,050
2,315,
2,490=
fvjax:
(22) 0162 x,3'lz
(10) 014$°x3
5,
3;275,
3,695',
3;970
2820`-3,180
.3,425
HUC04121SDS . -
•. •
-
39tis
'_ "11 ;
-
(14)1/4"' x 21/2" SDS
.(6) Ya' x21h" SDS,:
2 2f�S
SjU45
5,045
5,045'
3 6 3Ei"i
3,630
3 6,36.
HGUS412_'
-
35A
107ks
4 ;
-=
-`(56),0.762 x 3'h'
,(20)°0162z 3Yz j
5,040
9,400
9,400
� 9,400
i 8 085
8,085
8,085
LGU3.63 SDS , ; '
•
" ,=
35%
8 to 3D
41h,
,-
{16)1/4'' X 2?%z" 5DS
(12)1/a"- 21h" SDS;
5,555
6,720
6,ZX
6,72014,840
i
4,840
4,840`
. a
`_
.
3A
9Y4f030z
'
4=
z
d"SIDS,
,
,509A509,50�
6805MGU3.63=S
68051_6,805/2z
�..
:.
HGU3:63=SDS _
• •
.'. _ .. °{:36/s
l
ii.to3'Q
91/z
�-
136iJ,/vx2ih" 5DS
f241 1/a X2 --°SDS
Sd. Bt t
iS t1
J.1fs(i�1
1Gtl)
f t.53<
XA
_47tii
46 See footnotes on p.150.
THA/THAC
Adjustable Truss Hangers
�G��EERFO
W a
o�
E
This product is preferable to similar connectors because
of (a) easier installation, (b) higher loads, (c) lower installed
cost, or a combination of these features.
The THA series have extra long straps that can be field -formed to
give height adjustability and top -flange hanger convenience. THA
hangers can be installed as top -flange or face -mount hangers.
THA4x and THA2x-2 models feature a dense nail pattern in the
straps, which provides more installation options and allows for
easy top -flange installation.
Material: See table
Finish: Galvanized. Some products available in ZMAX® coating.
See Corrosion Information, pp.13-15.
Installation:
• Use all specified fasteners; see General Notes.
The following installation methods may be used:
• Top -Flange Installation — The straps must be field formed
over the header — see table for minimum top -flange requirements.
Install top and face nails according to the table. Top nails shall
not be within 1/4" from the edge of the top -flange members. For
the THA29, nails used for joist attachment -must be driven at an
angle so that they penetrate through the corner of the joist and
into the header. For all other top -flange installations, straighten
the double -shear nailing tabs and install the nails straight into
the joist.
• Face -Mount (Min.) Installation — Install face nails according
to the table, with at least half of the required fasteners in the top
half of the header. Not all nail holes in the straps will be filled.
Nails must have a minimum 1/2" edge distance. Straighten the
double -shear nailing tabs and install the joist nails straight into
the joist. The face -mount (min.) installation option accommodates
conditions where the supported member hangs either partially or
entirely below the header.
• Face -Mount (Max.) Installation — Install face nails according to
the table. Not all nail holes in the straps will be filled except for the
following models: THA29, THA213, THA218 and THA413. For all
other models with more nail holes than required, the straps may be
installed straight or wrapped over the header, with the tabulated
quantity of face nails installed into the face and top of the header.
The lowest four face holes must be filled. Nails used for the joist
attachment must be driven at an angle so that they penetrate
through the corner of the joist into the header.
• Uplift — Lowest face nails must be filled to achieve uplift loads.
Options:
• THA hangers available with the header flanges turned in for
35/e" (except THA413) and larger, with no load reduction —
order THAC hanger.
Codes: See p.12 for Code Reference Key Chart
13/4' for
THAC422
for
122-2
126-2
THAC422
typical
for THA422-2
THA426-2
THA418
Double 4x2— 2face nails
Use full table value (total)
Single 4x2 4 top nails
See (to
Face nails Top nails nailer table
per table per table
�F
Straighten the
double shear nailing tabs
Straighten the double
and install nails straight
shear nailing tabs and install
nails straight into the joist
T
Typical THA422
Top Flange Installation
Typical THA Top Flange
on a 4x2 Floor Truss
Installation on a Nailer
(except THA29)
THA422 Face -Mount
(Max.) Installation
Straps maybe installed straight
or wrapped over with tabulated
face nails installed into top
and face of headE
® Double -Shear i
Double- Nailing Dome Double Shear
Shear Side View; Nailing Side View
Nailing Do not (Available on
Top View bend tab C some models)
THA44 Face -Mount
(Min.) Installation
lyplual I rlmeu
Top Flange Installation
or to
tnote 5
p.187
86
•
Simpson.. ... Construction Connectors
THA/THAC
Adjustable Truss Hangers (cont.)
IS These products are available with additional corrosion protection. For more information, see p.15.
f ,01
IA
SIMPSON
11/z —
(2) 0.148 x 3
(6) 0.148 x 3
1 (4) 0.148 x 3
525
11,750
1,750
1 1,75),
450
11,330
11,330
1,330
THA29
18
15/a
911ti6 51/e
27/is —
(4) 0.148 x 3
(6) 0.148 x 3
(4) 0.148 x 3
525
2:610
2,610
2,610
450
1,985
1,985
1,985
THA213`:
18
15/a
13fis 5Iz
1 do
1 60
j,
THA218
18
1 %
17-316 51/z
2 —
(4) 0148 x 3
(2) 0148 x 3
(4) 0.148 x 11/2
—
11460
:0
1,460
—
1,110
i 110
1 110
THA2182
6
311a'171hs
8 '
2
(4)0.162x"311ia(2}Oc162X31h
'(fi)Q148x3
1.9ty
S 93'.
191 ,.9G
T
ig1z '.
FL,
A
THA222r2
16
31/a
223/1s 8
2 I —
(4) 0.162 x 31/z
(2) 0.162 x 31/z
1 (6) 0.148 x 3
1
11,960
11,9935
1,995
1:490
11,515
1515
THA418 116 1 35/a 1171/z 1 77/a 1 2 1 — (4) 0.162 x 31/zl (2) 0.162 x 31/z 1 (6)0.148x3 I — 11,96 11:9951 1,995 1 — 11:490.1 1,515 1 1;515
THA426 114 1 35/a 126 1 77/a 1 2 1 — 1(4) 0.162 x 31/2I (4) 0.162 x 31/z 1(6) 0.162 x 31h1 — 12,43512,435 I 2,435 1 — 12,095 12,095 1 2,095
FL I
THA426-2 114 171/4 I261/sl 93/4 I 2 I — I(4) 0.162 x 31/z1 (4) 0.162 x 31/z I(6) 0.162 x 31/z1 — 13,330 13,3301 3,330 • I — 12,865 1 2,865 1 2,865
THA29 118 115/a 1911/61 51/a 1 — 1 911tis 1 — 1 (16) 0.148 x 3 1 (4) 0.148.x 3 1 525 12,265 12,265 1 2,265 1 450 11950 11950 1 1950
THA218 18 1 % 1173A61 51/z 1 117'6 1. (18) 0.148 x 3 1 (4) 0.148 x 3 1 855 12,45012,450 1 2,450 1 735 12105 1 2105 1 2105
THA218 2-16]31/a 171ttis 8 41hs (22) 0,142=x'31/2 (, 0.162 x 31/z 1855 � �1 � w10 IBC,
_ FL,
THA222-2 16 31/a 223/s 8 1 1 141tis 1 1(22) 0.162 x 31/z (6) 0.162 x 31/z 1,855 3;310 3.310 1 .3,3.4 11,595 2:8452,u45 2,845 LA
THA418 116 1 3% 1171/z 1 77/a I - 1141/e I — 1(22) 0,162 x 31/zl(6) 0.162 x 31/2I 1,85513:31013:3101 3,310 115935 12,84512,8451 2,845
THA426 114 135/a 126 1 77/a I — 1161/s 1 — 1(30) 0.162 x 31/z1(6) 0.162 x 31/z1 1,855 1 4,415 14,480 1 4,480 11,595 1 3,795 1 3,855 1 3,855
71/4 261/s 93/a — 18 — (38) 0.162 x 31/2 (6) 0.162 x 31/z 1,855 5,520 5,520 5,520
THA�26-2 14 1,595 4,745 4,745 4,745
1. Uplft loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other loads govern.
2. Wind (160) is a download rating.
3. Min. top flange refers to the minimum length of strap that must be field -formed over the header. The tabulated bads for the THA29 with 11h" min.
top flange are based on a single 2x carrying member; all other top -flange installation loads are based on a minimum 2-ply 2x carrying'member.
For 4x2 truss carrying members with double top chords, use the specified fasteners for full tabulated values. For single 4x2 top chord or nailer
applications, refer to the Nailer Table.
4. Face -mount installation bads are based on a two-ply 2x carrying member minimum. For single 2x carrying members, use 0.148" x 11h" nail in
the carrying member and tabulated fasteners in the carried member, and use 0.80 of the table value for 18 gauge, and 0.68 of the table value for
16 gauge and 14 gauge.
5. For the THA 2x models, one strap may be installed vertically according to the face -mount nailing requirements and the other strap wrapped over
the truss chord according to the top -flange nailing requirements (see drawing on p. 186) and achieve full tabulated top -flange installation loads.
6. Refer to installation instructions regarding fastener installation into carried foist) member. Based on the installation condition, nails will be installed
either straight with straighted double -shear nailing tabs or slanted.
7. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
FL I
Simpson Strong -Tie® Wood Construction Connectors
Face -Mount Joist Hangers
2G`��ERFp10.
This product is preferable to similar connectors because
of a) easier installation, b) higher loads, c) lower
installed cost, or a combination of these features.
T he double -shear hanger series, ranging from the light -capacity
LUS hangers to the highest -capacity HGUS hangers, feature
innovative double -shear nail;ng that distributes the load through
two points on each joist nail for greater strength. This allows for
fewer nails, faster installation and the use of all common nails for
the same connection.
For medium -load truss applications, the MUS offers a lower -cost
alternative and easier installation than the HUS or THA hangers,
while providing greater load capacity and bearing than the LUS.
Material: See tables on pp. 194-195
Finish: Galvanized. Some products available in stainless steel
or ZMAX® coating. See Corrosion Information, pp.13-15.
Installation:
• Use all specified fasteners; see General Notes.
• Nails must be driven at an angle through the joist or truss
into the header to achieve the table loads.
• Not designed for welded'or hailer applications.
Options:
• LUS and MUS hangers cannot be modified
• Concealed flanges are not available for HGUS and HHUS
• Other sizes available; consult your Simpson Strong -Tie
representative
Codes: See p.12 for Code Reference Key Chart
Double -Shear
Nailing
Top View
Double Shear Nailing
Side View
Do not bend tab
Dome Double -Shear
Nailing Side View
(Available on
some models)
1' for 2x's
1''A for 4x's
m:pRm
t O; H
G
q- m
c-w a
LUS28
HHUS210-2
PM
11/g°
n'p. �.
0
e.
HUS210
(HUS26, HUS28,
and HHUS similar)
HGUS28-2
Typical HUS26
Installation
with Reduced
Heel Height
(multiple member
fastening
by Designer)
19
Simpson Strong-TieO Wood Construction Connectors
v
Face -Mount Joist Hangers (cont.)
Model °
Min.
Heigi
Dimensions (in.),
Fasteners .
g CHeel:
-CarardedNo.
lyemin
66rW
�, . Member �'•
Single 2x Sizes
'LIJS24
25/e ,�
8'
1 s/e
31/8
1 a
-(4) 0148 0 ; : r (2) 048""i 3"
HUS26
4Y.::
' l sfie
`43/a
fl/
(4) i0148 x 3: ,. (4),0.148 x 3
MUS26
411/15
18
1 %
53A6
2
(6) 0.148 x 3 (6) 0.148 x 3
HUS26
45/ie
16
15/e
5%
3
(14) 0.162 x 31/2 (6) 0.162 x 31/2
HGUS26�
, 40M5' "
12 �
-=15/3 :
53/8
6,
(20)-0.162 x 312, " (8) Or162'z 31h
LUKT'
4�+6 '.",AS
11Y16
�.651a "�°-I'/a
�',(6}0148x:3 �h.�4(4)0,148x3 '.
MUS28
65A6
18
19AG
6'3A6
2
(8) 0.148 x 3 (8) 0.148 x 3
HUS28
61/2
16
"15/8
7
3
(22) 0.162 x 31h I (8) 0.162 x 31/2
HGUS28
6"A6
12
1 %
71/e
5
(36) 0.162 x 31/2 i (12) 0.162 x 31h
;LUS210,,
4"1/a,`
"18" ",
19/5
"TY16
I "i�la' '
(8)'0,148•x3-'",(
HUS210 `,
` 83/s '_
16
15/s .
9
3
(30) 0:162 x 3l2 (10) 0.162 x 31/2
HGUS210
8V6'=
12: "'
15/e
9�7e.,
'•(46)-0162x3'/z";(16)0:162x312�
1. See table below for allowable bads.
Single 2x Sizes "
These products are available with additional corrosion
protection. For more information, see p.15.
For stainless -steel fasteners, see p.21.
Many of these products are approved for installation
1 with Strong -Drive® SD Connector screws.
See pp. 335-337 for more information.
a
LUS26
1,165
865
1 990
1,070
1 1,355
1 1,165
935
1 1,070
1,150
1 1,475
865
1 635
725
1 785
1,000
IBC, FL,
MUS26'
93'01i.
:1,295",
1,480 "
1,560.
1',560
T, 980' `'�1,405"
.,1,560
1,560
1560
810"
968,
1090.
1,180
5
LA
HUS26
1,320
2,735
3,095
3,235
3,2335
1,320
2,960
31280
37280
3,280
1,150
2,350
2,660
2,780
2,780
HGUS26
875`
,:4,340` ,
= 4;850. °
5,170,-,'
"5,390 "
< b75""..
' 4,690`
,22d
5;390
5390
"` ?£30 ;,
3,225 "
3,61t) ""
°3,870.
3,985
IBC, FL
LUS28
1,165
1,100
1,260
1,350
1,725
1,165
1,195
1,360
1,465
1,730
865
810
925
1,000
1,270
MU528'
1,32
1,730, .
1,97
, 2,125 ;:
_,2 255
` ' .
,1875
2j135
-2,255.
2,25 z
5
". 1 (50
; 1,270
•
1,455
" 1;57
1 551
LA
HUS28
1,760
4,095
4,095
4,095
11 4,095
1,760
4,095
4;095
4 095
4,0no
1,480
3,520
3,520
3,520
3,520
HGUS2$ _
1,650=
7 7
: 7,275
7,275 "
7;275
s 1 6a a"
> ,2to.
1. �275
;275
7,275
1,325
3.6710
3,820-
3,915,.
.4,250".
IBC, FL
LUS210
1,165
1,335
1,530
1,640
2,090
1,165
1,450
1,655
1,775
2,270
865
985
1,120
1,215
1,500
IBC, FL,
HUS210
, "5y
5,4a0'
9` 5 795'
S,830 ":
5,f330
2,635 "
;' S a95 "
a,78G ,
a 3^�
L z 0
" 2.220
2,330
2 r" "
HGUS210
2,090
9,100
9,100
i 00
9,100
2,090
9100
9100
9,100
9;100
1,545
6,34
61730
6,730
6,730
IBC, FL
1. For dimensions and fastener information, see table above. See table footnotes on p. 195.
HHUS/HGUS
See Hanger Options information on pp. 98-99.
HHUS - Sloped and/or Skewed Seat
• HHUS hangers can be skewed to a maximum of 45' and/or sloped to a maximum of 45'
• For skew only, maximum allowable download is 0.85 of the table load
"
• For sloped only or sloped and skewed hangers, the maximum allowable download
of
1
is 0.65 of the table load
•. Uplift loads for sloped/skewed conditions are 0.72 of the table load, not to exceed 2,475 lb.
""
cute
• The joist must be bevel cut to allow for double shear nailing
side
HGUS - Skewed Seat
HGUS hangers can be skewed only to a maximum of 45°. Allowable loads are:
HGUS Seat Width Joist Down Load Uplift
Specify angle
W < 2" Square cut 0.62 of table load 0.46 of table load
Top View HHUS Hanger
W < 2" Bevel cut 0.72 of table load 0.46 of table load
Skewed Right
2" < W < 6" Bevel cut 0.85 of table load 0.41 of table load
Qoist must be bevel cut)
All joist nails installed the
2" < W < 6" Square cut 0.46 of table load 0.41 of table load
outside angle (non -acute side).
W > 6" Bevel cut 0.85 of table load 0.41 of table load
94
Simpson Strong -Tie° Wood Construction Connectors SIMPSON
•
0
a
a
0
0
U
r
0
z
0
cc
m
z
0
91
a
7E
m
0
0
0
U
0
s5 •
4,.
sss
ri
SS=
{A
wa
7
These products are available with For stainless Many of these products are approved for installation
additional corrosion protection. ED steel fasteners, ! with Strong -Drive® SD Connector screws.
For more information, see p.15. see p. 21. See pp. 335-337 for more information.
Dimensions {in) Fasteners (tn.) DF/SP Allowable Loads . SPF/HF Allowable Loads
Model Code
Heeh
No Height;, W"� H B caCrymg Carried Up11ft Floor' °Sn6w Roaf INird Uplift ;Floor :Snow- Roof v±iindtMember (160) "(100) (ii5) (�125) (160) (160) , (100) •(:1,15j (125) ,(160)"
Double 2x Sizes
HHUS26-2 4-'A6 14 3-A6 I 53/e 1 3 1 (14) 0.162 x 31/z 1 (6) 0.162 x 31/z 1,320 2,830 3,190 1 3,415 1 4,250 11,135 1 2,435 2,745 12,935 3,655
HGUS26-2 0% 12 35ii6 I 57/is 1 4 1 (20) 0.162 x 3Yz (8) 0.162 x 31/z 2,155 4,340 4,850 15,170 15,575 11,855 13,730 14,170 14,445 4,795
71/4
;435 l,14t IBC, FL,
4;435 5,145 1 LA
I1l9UJ2b-3 ;)
4;49e°°
I'2
49AZ
bV2
- A.
1 (ZU)U]bZX6'/2
(6)9;1bZX392"
2";10b.
4„64U
4,bN
1 0,1JU
I o,010
1,=J
d,tju:,l
4,111U
4,443
4,1y5,
IBC, FL,
VIA6 `
12
4,15A6
7114
4'
(36) 0.162 x 3112'
,(12) Q162x 31h
3,2',35
7,460
7,460
7,460
7,460
2,780
.6,415
6,A:15
6,415
6;415
LA
HHUS210-3
83/s
14
411A6
87/8
3
(90) 0.162.x 31/2
(10)(3.16201h
3,405
5,630
6,375
6,485
1 6,485
2,930
4,840
5,485
5,575
5,575
FL
HGUS210-3
813/i6
12
415/i6
91/4
4
(46) 0.162 x 31/2
(16) 0.162 x 31/z
4,095
9,100
9,100
9,100
9,100
3,520
7,825
7,825
7,825
7,825
HGUS212-3 ,
105/a :
12"
41.A
1031a
~`4"'
(5B)'0162 x 31%z
2(20) 0;162 x 311z
_,095,
9,04` -
P 145
045"
W04
?;900,
r,780
'T 80
7,780
,78t0,.
IBC, FL,
LA
HGUS214, 3)
125/s
_� 12 :
'415hc
123/a
„4
(6f) 0:62 x 3'/i
'(22) Q 162�x 34h
5,695
10,125';10,i25
10;1�5
10,125
4,900
'; 8,190;
-8;190.
8,190
$,190
Quadruple 2x Sizes
HGUS26-4
51h '
, 12 .
6`A,,
57/is
`4
'(261o.l62x31/z
8):Oi162X31V2
.2155
4,340}
4,850
:5,170
'5575
'1,855
:8,730.
4,170
4,445
4;795
IBC, FL,
HGUS28-4
71/4
12
61/16
73A6
4
(36) 0.162 x 31/2
(12) 0.162 x 31/2
3,235
7,460
7,460
7,460
1 7,460
2,780
6,415
1 6,415
6,415
1 6,415
1 LA
HHUS210-4
8%
14
6'/s
87/a
3
(30) 0.162 x 31/z
(10) 0.162 x 31/z
3,405
5,630
6,375
6,485
16,485
2,930
4,840
5.485
5,575
5,575
FL
OGUS210-4,
91/a
12
63iifi
93Aa
4
(46) 0.162 x 31/z'
{16)"fl.162 z 31h
.4;095,
9,100
9,100
.9,T00
-9,100`
3,520
7,825
7825
7,825,
7,825
'-HGUS212 4
105/e
< 12
6s e
1051s
4
(56)'0162 x 31/z
' (20) 0,162x 31h
T,69
_0 '
0, 4a""-
,045.
9;045
4,q ti
; % 0
:�,f�sir
r,78(}
7�7?6
IBC FL,
LA
4x Sizes
1 LUS46 , 4% 1 18 1 $% 1'43/4' '`2 (4) 0.162 x 3%, 1" (4) 0.162 X 31/211,0£.01 1,030 ] f,170.11,265'1 1 5951 310 •1 885 11;0051 1„090 1 1;370' 1 IBC, FL
LUS48
43/8
18
1 39A6
63/4
2
1 (6) 0.162 x 31h
(4) 0.162 x 31h 1
1,060
1,315
11,490
1,61012,0301
910
1,130
1,280
1,385
1,745
1 IBC, FL,
HUS48
61/6
14
3%
7
2
(6) 0.162 x 31h
(6) 0.162 x 31/2
1,320
1,580
1,790
1,930
2,415
1,135
1,360
1,540
1,660
2,075
LA
HHUS48
61/2
14
3%
71/s
3
(22) 0.162 x 31/2
(8) 0.162 x 31/2
1 760
4,265
4,810
5,155
1 5,980
1,515
3,670
4,135
4,435
5,145
HGUS48
67/6
12
3%
71/16
4
(36) 0.162 x 31/z
(12) 0.162 x 31h
3,235
7,460
7,460
7,460
7,460
2,780
6,415
6,415
6,415
6,415
;LUS410
�.'.':1
6'14 i
18'
3�6:
'83<a
"2'
�(8)0.1�2 31h;
(6),0:162;x3'1/z
�;4 u'
1,830j1.;2,075
2,245,
2;830
1= 4.;,
1,575
it785
1;93Q
2,435_
HGUS410- `' -
87/6
.> 12.
3578
91hs
, �4
(46) 0:162x'31/2
`(16) 0.162�x 31h
4,095
,, loll"
� 9;100
°9,100
9,100
3,520
�; 7,825
7825
7,825
7825�,
IBC FL,
LA
HGUS412
1034.
12
35/s
107/6
4
1 (56) 0.162 x 31/2
(20) 0.162 x 31/2
5,695
19,045
9,045
9,045
9,045
4,900
7,780
7,780
7,780
7,780
HGUS414
117/�6
12
35/a
121A�
4
1 (66) 0.162 x 3/h
(22) 0.162 x 31/z 15,695
110,125
10,125
10,125
10,125
4,900
18,190
1 8,190
8,190
1 8,190
Double
4x Sizes
HGUS7.37/101 8% ;
12"d
7%
1 8'/�6
"4.
(46)0:1"62_X'Ui
(16)10:162x31h 131,4301
9,095,1,.g;095
9,095-
9;095
1 2,950':
7,820
7,820 17,820
17,820
FL
1. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern.
2. Wind (160) is a download rating.
3. Minimum heel height shown is required to achieve full table loads. For less than minimum heel height, see technical bulletin T-C-REDHEEL at strongtie.com.
4. Truss chord cross -grain tension may limit allowable loads in accordance with ANSI/TPI 1-2014. Simpson Strong Tie® Connector Selector® software includes
the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie.
5. Loads shown are based on a two-ply 2x carrying member minimum for nailed hangers. With 3x carrying members, use 0.162" x 21h" nails in the header
and 0.162" x 31/2" in the joist, with no bad reduction. With single 2x carrying members, use 0.148" x 11h" nails in the header and 0.148" x 3" in the joist,
and reduce the load to 0.64 of the table value.
6. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
SIMPSON
t
HTU
Face -Mount Truss Hanger
The HTU face -mount truss hanger has nail patterns
designed specifically for shallow heel heights, so that
full allowable loads (with minimum nailing) apply to
heel heights as low as 37/s". Minimum and maximum
nailing options provide solutions for varying heel
heights and end conditions.
Alternate allowable loads are provided for gaps
between the end of the tniss and the carrying member
up to'/2" max. to allow for greater construction
tolerances (maximum gap for standard allowable loads
is %" per ASTM D1761 and D7147). See technical
bulletin T-C-HANGERGAP at strongtie.com for
more information.
Material: 16 gauge
Finish: Galvanized
Installation:
• Use all specified fasteners; see General Notes
• Can be installed filling round holes only, or filling
round and triangle holes for maximum values
• See alternate installation for applications
using the HTU26 on a 2x4 carrying member or
HTU28 or HTU210 on a 2x6 carrying member
for additional uplift capacity
Options: -
• HTU may be skewed up to 671/2'. See Hanger
Options on pp. 98-99 for allowable loads.
• See engineering letter L-C-HTUSD at strongtie.com
for installation with Strong -Drive® SD fasteners.
Codes: See p.12 for Code Reference Key Chart
Min. heel
height
per table
Many of these products are approved for installation with Strong-Drivee
SD Connector screws. See pp. 335-337 for more information.
HTU26
Typical HTU26
Minimum Nailing
Installation
a o
oA'�
ga Ito
o
dt(
max. gap between end'of'•'
truss and carrying member
HTU Installation for
Standard Allowable Loads
(for'h" maximum gap,
use Altemate Allowable Loads.)
Standard Allowable Loads (1/8" Maximum Hanger Gap)
2x Sizes
Alternate Installation -
HTU28 Installed on
2x6 Carrying Member
(HTU210 similar)
;_. ;. ,t J=: 'rl
,,
1-..
I U . 'f
072
j4U1.U.1ve A X12_
5. Ji#ois7 , u a z
a. ..
1,aoa -c,yffu
? a wry
you
't;u,iu -
i,��,
c,0au;
c,aslal
„0,90' r:
IBC,
HTU28 (Min.)
37/s
15/a
71As
31/2
(26) 0.162 x 31/2
(14) 0.148 x 11/2
1,235 3,820
3,895
3,895
3,895
1,060
2,865
2,920
2,920
2,920
FL,
HTU28 (Max.)
71/4
1 %
71/s
31/2
(26) 0.162 x 31/2
(26) 0.148 x 11/2
2,020 i 3,820
4,315
4,655
5,435
1,735
3,285
3,710
4,005
4,675
LA
HTU210 (Mini
i ' 37/s ,
15/s
9{/s•.
Th"
(32)"0.1K x 3%
° (14),U.148 x 1 /2
,,1,330' 300
A 3s0
-4,3t3o
4,300 '
1,145,
3 22v�
3,Tt5'
3,225'_
3 22
,HTU210 jMax;)
#. 91Ia
15/9 "
91fis
31h
(32) 0.162x 3'A
(32) 0.148 x V/2
'-,3,315 4,705
�,310
€ ' G �
: 5,995
2,850
4,045 =
'r565-
4,93rJ
. 5;155
Double 2x Sizes
HTll2 4(Min;) ;
37Is D
35/ia
:;5.hs,.
, 31/2
';(20) 062
x 31/2
, {14} 0.148
x 3
],515';, a 2;940.
i, i ti
, s s
3,910
; 1,305'
1,850 ,
2 090;
'2 255 ;
,2,465;'
HTU26-2 (Iv1aX }
5t12 '
A,;
5?Is9„`3'h
(20) 0,162,x
31/2
(20).0.140�x
3
2;175 '2,940
"3 32 ,1,
?« $('
.4,4$
1",870 ,
2,530°'
2t355
; .080
3,855,
HTU28-2 (Min.)
37/8
35Ae
71/16
31/2
(26) 0.162 x 31/2
(14) 0.148 x 3
1,530 3,820
4,310
4,310
4,310
1,315
2,865
3,235
3,235
3,235
IBC,
HTU28-2 (Max.)
7 /4
3-A6
7 As
3 h
(25) 0.162 x 31/2
(26) 0.148 x 3
3,485 3,820
4,315
4,655
825
2,995
3,285
3,71101 -
Q6,5
i , '10
LA
010-2 (Min.).
37%
3 6,,
914s
31/2
(32) 0.162x 31/2
�"� (14) 0.148 x 3,
1,755, 74,705
= 4,81
4.815•
4;81S
, ° 1,510:
3;530.1
3,610
-3t610
f'"3,610:-
1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member.
2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch.
3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern.
4. Wind (160) is a download rating.
5. For hanger gaps between 'A" and 1h", use the Alternate Allowable Loads.
6. Truss chord cross -grain tension may Emit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie° Connector Selector° software
includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie.
7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11/2" nails in the header and
reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad.
8. Fasteners: Nail dimensions in the table are fisted diameter by length. See pp. 21-22 for fastener information.
96
r
6
z
z
a<
ii
0
U
H
0
z
0
Cl)
0
a
I
CO
rn
0
N
O
0
N
U
HTU
Face -Mount Truss Hanger (cont.)
' Many of these products are approved for installation with Strong-Drivee
SD Connector screws. See pp. 335-337 for more information.
Alternate Installation Table for 2x4 and 2x6 Carrying Member
NoHeigtit
;Carryings
Carrying
Carded
Upirfi
Floor
:Snow
Roof
Wind;,,Uplift
.'Floor
Snow,
"Roof '
Wind
Ref.
y..,
„
.{in)
Member.
.", re
_,
Memperl;
Member
(ifi0}
(100}
' (115} .(125)
..
(160)
d160)
(100)
- (115) ,
`{125)
(160)
HTU26 (Min.)
37/a
(2) 2x4
(10) 0.162 x 31/2
(14) 0.148 x 11/2
925
1,470
1,660
1,, 90
1,875
795
1,265
1,430
11540
1,615
HTU26 (Max.)
51/2
(2) 2x4
(10) 0.162 x 31/z
(20) 0.148 x 11/2
1,240
1,470
1060
1,790
2,220
1065
1,265
1,430
1,540
1,910
113C,
un 19u mnzv V.'
; 41i
ii
t,)nx n 1F,) Y q1x,6kti
n ea'v 1 v
1 47'1)�.
' 9 4en
1, ff
`r4.-nn
9 rzn
-' 9 srrr
� ,7pr1-
z qsa°
FL, LA
1. See table above for dimensions and additional footnotes.
2. Maximum hanger gap for the alternative installation is 1h".
3. Wind (160) is a download rating.
4. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
Alternative Allowable Loads (1/2" Maximum Hanger Gap)
Dimensions (m) ' Fasteners {in.} DF/SP Allowable Loads SPHHF Allowable Loads
Model -Mn:Code:
. HeeV
NoHeight W H g Carrying carried ljplift Floor Snow "Root Wind�� Uplift Floor SnowRoof Wind Ref.
Memhec Member (160}.. " (100) (f15) (125) (160).: (160) ;(100) (1y5)- (125), ;(160)
Single 2x Sizes
HTU28 (Min.)
37/a
15/a
7'tia
31/2
(26) 0.162 x 31/2(14)
0.148 x 11h
1,110
3,770
3,770
3,770
3,770
955
2,825
2,825
2,825
2,825
IBC,
FL,
HTU28 (Max.)
71/4
15/a
711ie
31/2
(26) 0.162 x 31/2
(26) 0.148 x 11/2
1,920
3,820
4,315
41655
5,015
1,695
2,865
3,235
3,490
3,765
LA
HTU210 (Min.)
371a
�ta/a ;
9Ye-31h
'(32) 0.162-x<31/z
(14) 0:1485 11h
:1,250`
3,600
3,600
3;600
3,600�
1,075
2,7002,�00
2,700
2,700
HT11210 (Max.) .
�`= 91/4
1$/a
,9% ,
31h
"(32) 0.162 x 31/2
(32) D:148 ic1:1h.
'3i255
„4,705
_5,020
;5,Q20
5,020
2,800,
,3,530
3,765
3,765
3,765 '
Double 2x Sizes
HTU26:r2 (Min)
"3Ja.'"
3 a
`57tia
31/s:
(20) 0162 x'311z.
, (14) 0,148,x 3 .,
1,515
_2 940
3 32i'
3,500
3;500 '
1,305
2,205
2;205
2,205
2,205 !.
HTU26,-2 Max.)
(
1
. " 5 h
3 a
- 57J�6 '
1
3 h
t
(20) 0.162 x 3I2
(20) 0.148z 3 '
1,910
2 940
.
3,0
3,500
3,500; _
1,645
2,205 °
2,205
2,205
2 205
HTU28-2 (Min.)
37/a
31ye
711ia
31/2
(26) 0.162 x 31/2
(14) 0.148 x 3
1,490
3,820
3,980
3,980
3,980
1,280
2,865
2,985
2,985
2,985
IBC,
HTU28-2 (Max.)
71/4
3-A6
74A6
31/2
(26) 0.162 x 31/2
(26) 0.148 x 3
3,035
3,820
4,315
4,655
5,520
2,610
2,865
13,235
3,490
4140
FL,
LA
1. The maximum hanger gap is measured between the joist (or truss) end and the carrying member.
2. Minimum heel heights required for full table bads are based on a minimum 2:12 pitch.
3. Uplift loads have been increased for earthquake or wind loading with no further increase allowed. Reduce where other bads govern.
4. Wind (160) is a download rating.
5. For hanger gaps between Ma" and 1h", use the Alternate Allowable Loads.
6. Truss chord cross -grain tension may Emit allowable bads in accordance with ANSVTPI 1-2014. Simpson Strong -Tie Connector Selector® software
includes the evaluation of cross -grain tension in its hanger allowable bads. For additional information, contact Simpson Strong -Tie.
7. Loads shown are based on a minimum two-ply 2x carrying member. For single 2x carrying members, use 0.148" x 11/2" nails in the header and
reduce the allowable download to 0.70 of the table value. The allowable uplift is 100% of the table bad.
8. Fasteners: Nail dimensions in the table are listed diameter by length. See pp. 21-22 for fastener information.
19
HU/HUC/HSUR/L
Medium -Duty Face -Mount Hangers
HU/HUC hangers may be installed on a masonry/concrete wall
as described below. Additionally, HU hangers with one flange
concealed may be installed similarly.
HU and HUC products are heavy-duty face -mount joist hangers
made from 14-gauge galvanized steel.
• The HUC is a concealed flange (face flanges turned in)
version of the HU.
• HU is available with both flanges concealed, provided the
W dimension is 25/15" or greater, at 100% of the table load.
Specify HUC.
• HU is available with one flange concealed when the W dimension
is less than 25/1e" at 100% of the table load. Specify as an 'X'
version and specify flange to conceal.
• For any HU or HUC shown in this catalog, the user may
substitute all face nails with'/4" x 13/4" Titen® 2 screws
(Model TTN2-25134H) for concrete and '/4° x 2W' Titen 2
scraois (f,4odel TT1\12-252341-1) for GFCMU. Follow all
installation instructions and use the loads from the sawn
lumber or RNP sections.
Material: 14 gauge
Finish: Galvanized; ZMAXII and stainless steel available
Installation:
• Attach the hangers to concrete or GFCMU walls using
hex -head Titen 2 screws. Titen screws for GFCMU ('/4" x 23/4" —
Model 7TN2-25234H) and for concrete ('/4" x 13/4" — Model
TTN2-25134H) are not provided with the hangers.
• Drill the 3/e"-diameter hole to the specified embedment
depth plus'/2".
• Alternatively, drill the 3/ie"-diameter hole to the specified
embedment depth and blow it clean using compressed air.
• Caution: Oversized -diameter holes in the base material
will reduce or eliminate the mechanical interlock of the
threads with the base material and will reduce the anchor's
load capacity.
• Titen Installation Tool Kts are available. They include a
3/1a" drill bit and hex -head driver bit (Model TTNT01-RC);
a 3/,s" x 4'/2" drill bit is also available (Model MDB18412).
• A minimum edge distance of 1'/2" and minimum end distance
of 37/3" is required as shown. in Figure 1 for full uplift load.
• %Nhere no uplift load is required, a minimum end distance
of 11/2" is oermitted.
Codes: See p.12 for Code Reference Key Chart
Concealed flanges
HUC410
37i
di,
HU214
Figure 1 — HUC410 Installed on
Masonry Block End Wall
Figure 2 — HUC410 Installed on
Masonry Block End Wall
23
Simpson Strong-TieO Wood Construction Connectors r "Ok
HU/HUC/HSUR/L
............... __... ._..... _..------------.._...... ---._........... _.... _...... _..... ... _..... _ .__...._.__....._..........._..----- _
Medium -Duty Face -Mount Hangers (cont.)
These products are available with additional corrosion protection. For more information, see p.15.
t�=
a
U
yr's
able,
�Na
HU26
HU26X
(4)1/4 x 23/4
(4)114 x 13/4
(2) 0.148 x 11/2
335
1,000
335
1,545
HU2$
HU28X `
{6)1Ia!x 23/4, , -
.'; (6)
148
760
A- _'2 400
HU24-2
HUC24-2
(4)1/4 x 23/4
(4)1/4 x 13/4
(2) 0.148 x 3
380
1,000
380
1,545
HU26-2 (Min:) .
HUG26 2
(871/a`X 23/a
(8} 1/4'x 131a
(4) 0148 x.3
760
2,000
HU26= ', (Max) , ,
HUC26 2
(12)1l4 x 23/4
{12)1/4 x j 3/a
y .(6) 0.14$ x 3
, 1,135 , ,
3 D00 =
1,135
, 3;95Q
HU26-3 (Min.)
HUC26-3 (Min.)
(8) 1/4 x 23/4
(8)1/4 x 13/4
(4) 0.148 x 3
760
2,000
760
3,200
HU26-3 (Max.)
HUC26-3 (Max.)
(12)1/4 x 23/4
(12) 114 x 13/4
(6) 0.148 x 3
1,135
3,000
1,135
3,950
nucacitwlax.l r+uoGortimax� ;=r AlwJ(AEG%4; tI`!)74x:17a- to�.u.i+o-a:u m'..1�� - Q,Wu�. yior
HU210 HU21 OX (8)1/4 x 23/4 (8)1/4 x 13/4 (4) 0.148 x 11/2 545 2,000 1 760 1 2,415
HU21I.,
a
(18} Jx 23/40,Z(Max)
�` (18) Ya x 1314
, ;{10) 0148 X 3
1800
4300 ,
l;f UO
5 08b - `
HU210-3 (Min.)
HUC210-3 (Min.)
(14)1%a x 23/4
(14)1/4 x 13/4
RAW x 3
1,135
3,500
1,135
4,926
H0210-3 (Max.)
HUC210-3 (Max.)
(18)1/4 x 23/4
(18)1/4 x 13/4
(10) 0.148 x 3
1,800
4,500
1,800
5,085
HU212`
HU212X
(10)?Ja x 23/4 '
; n' (10)114 x 13/a
:.{6) 0.148 x 11h
1135
2 500 `.
1,135
HU212-2 (Min.)
HUC212-2 (Min.)
(16)1/4 x 23/4
(16)1/4 x 1314
(6) 0.148 x 3
1,135
4,000
1,135
4,920
HU212-2 (Max.)
HUC212-2 (Max.)
(22)1J4 x 23/4
(22)1/4 x 13/4
(10) 0.148 x 3
1,350
5,085
1,350
5,085
HU212-3 (Mm) _ '.
HUC219_13
(16)1/4 x 23/4 ,,
(16)1/a x 131a
(6) 0:148 x-3
"�1'135 ; "
' 4,000" .
1;135 ,.
' "4,,920
HU212 3 (MaX)
NUC212�3 (Nlax)" "
(22)114x 23Ja
�' (22
1,800 . °
:, 5085.,
1,800
5 085-
HU214
H0214X .
(12)1/4 x 2 3/4.
(12)1/4 x 13/4
(6) 0.148 x 11/2
1,135
2,665
1,135
2,665
HU214=2 (Min.)
HUG214 2 {Min) .
(1$)1la x 23/a"
(18)1Id X"131a
(8) 0.148 x,3
",11515 '
4,500
1,515- ,
' ' ;5,085.
HU2142 (Max.)
HUC214'y2,(MaX.}
(24} 1T X 23I4?
(24)1/4;x 13Ja r 1
(12) 0198 x 3
`2 015
5 085
f ; 2;Q15_5
085
HU214-3 (Min.)
HUG214-3 (Min.)
(1$) 1/4 x 23/4
(18)1/4 x 13/4
(8) 0.148 x 3
1,515
4,500
1,515
5,085
HU214-3 (Max.)
HUG214-3 (Max.)
(2 4) 114 x 23/4
(2 4) 1/4 x 13/4
(12) 0.148 x 3
2,015
5,085
2,015
5,085
HU216''
HU216X';
{18} ;1I X 23/a
{18) ?/a x46
1
1
20'5/
15
2 920
HU216-2 (Min.)
HUG216-2 (Min.)
(20)1/4 x 23/4
(20)1/4 x 13/a
(8) 0.148 x 3
1,515
4,920
1,515
4,920
HU216-2 (Max.)
HUC216-2 (Max.)
(26)1/4 x 23/4
(2 6) 1/4 x 13/4
(12) 0.148 x 3
2,015
5,085
2,015
5,085
HU216'3(Min)""
HUC216,=3(Mm}''
(20)11dx231a .;`
(20)1I4x","13/41
(8)014813
1515
4920;
j;515
4920 ''.
HU216 3 (Max.)
HUC2163 (Max)
(26)1/a x 23fa
` (26) ?/4 x 131<
(12} 0.148 x 3
2 015
"` . 5,085 -
2,015
5 085
HU7 (Min.)
(Not available)
(12)114 x 23/4
(12)1/4 x 13/4
(4) 0.148 x 11/2
545
2,980
760
2,980
HU7 (Max.)
(Not available)
(16)1/4 x 23/4
(16)1/a x 13/4
(8) 0.148 x 1112
1,085
3,485
1,085
3,485
H69-(Min )'
(Not available} e ,'';
(18?1/< x 23/a
{18)1/a X 131a
: '(6) 0,148 X 11h
135
3,230
1,135
' 3 230 ,
HU9°(Max)
(Not available) , , ,;
{24} 1f x 23/a ; T
(2A} 14 x'13/a
(10) 0.14&x 11h
° 1445
3 735.
1 4Q5
3A735 ;
HU11 (Min.)
(Not available)
(22)1/4 x 23/4
(22)1/4 x 13/4
(6) 0.148 x 11/2
1,135
3,230
1,135
3,230
HU11 (Max.)
(Not available)
(30)1/4 x 23/4
(30)1/4 x 13/4
(10) 0.148 x 1 %
1,445
3,735
1,445
.3,735
•38
STAGGER JOINTS - TYP.
PA15ED HEEL ROOF TRU55E5
ROOF SHEATHING- SEE PLAN
RAISED HEEL ROOF TRUSSES
B/SKI --II-I
-5EE
PLAN
-SEE PLAN
SOFFIUFASCIA- SEE ARCH.421
=`
z
�
W Q
W
aN
O S
a
RIBBON BOARD-
Q Q 3 ��
SEE SCHEDULE
U z LL
z
FOR SPACING 1
Z z
w
RIBBON BOARD- SEE
FASTENING TO w
N
�j > >
< a
N
SCHEDULE FOR SPACING !
TRU55E6
=
w F.-8 x
FASTENING TO TPU55ES
WALL SHEATHING-5EE PLAN
=_
Z In W
?
MIN. 15/32' CDX PLYWOOD OR
j
3
1/16' 05B WITH ad GUN NAILS
C
U
UPLIFT/SHEAR ANCHORMASONRY
WALL -
(0.131' X 2 1/2') 9 6' O.C. TO
RIBBON BOARDS
UPLIFT/SHEAR GYP. CEILING-
SEE PLAN
EACH TRUSS - SEE
5/SKI
SEE PLAN
ANCHOR EACH
SCHEDULE
PLAN
DO NOT FASTEN RIBBON BOARD
TRUSS- SEE PLAN
NOTE: ADD'L FRAMING NOT
INTO END GRAIN OF ROOF TRUSS
MASONRY WALL -
SHOWN FOR CLARITY
BOTTOM CHORD
SEE PLAN
_
LL•aREVISION'
RAISED HEEL TRUSS BEARING
'
A
RAISED HEEL TRUSS BEARING B
°
SCALE: NTS
SKI
SCALE: NTS SKI
RIBBON SCHEDULE
DESIGN CRITERIA
RIBBON MATERIAL
RIBBON SPACING
RIBBON ATTACHMENT
Vint=165 MPH
(2) 12d GUN (0.131' X 3')
lYas P.
2X4 SFF02
24'
TO EACH TRJ55, (4)
EXP. B,
NAILS AT JOINTS
ENCLOSED
VUIL=180 MPH
(2) 12d GUN (0.131' X 3')
lVasXP.
2X4 5PI'02
IV
TO EACH TRUSS, (4)
G, E
EXP.
ENCLOSED
NAILS AT JOINTS
I
SHEETTTTIE:
RIBBON 0—FOR
RUBE. RFEB ROOF IRUAFS
SHEET INFORMATION:
JOB NO:
pABF ISSYED: 11.08.1E
RFNEwFOBY: BN
SK.I
ALP ,
lz
MY AK.fNVC6,Y,PM' '
January 110) 2920'
America, ".1,
catpen Ontr actor.� of - merica, Inc:. 3910Avenue" 6 ,0,AVen;Nw
Winter 'R Haven, FL 3 8*,'8 00, , 62. 01
Dear ',Matt:
I f", h a a
.,o my'attentfon-thatsome questions were raised concerning ,S�/8,!'diameter'
"
holes ,.,," iIl67d'fh"fu,the: :chords'(wide l face) 'y ;i ofs gable,endtrusses to allow for
ese,gab
I
le,ends,are,,.over-continuous support`:
'
w 6fi6 fully
hill sheathedare. d.tillj6d.,;ib6iit,,th:&,,centerl'itlo,,p thewidt'
,
face rib.c' 'el my aging,,dify, bbi! t6f 0 r� 0-108 .... lb—,4 Mott, ainal ii C PlAt ��',verdc webs then
no:repairiisrequ, required only 8upports,Oet'affloor 'Ibadsand'nadddibonad
load:,
If YOU hai-ve,apy give -me-axall.
I ,AT.,,E,, OF
6780 Fbrupi.Drive, suite 305, Orlando, FL 3-2�?I�:- (4 ), 2 -97 -(, (8.63) -
do QQ 99 -�, �05 ,8685
422'
wyM.,al i i pinelttw..qqM.-
3e Q
P�
9
No. 66
'#
N MATE OF
;
F
ALPINE
ANITWCOMPANY
COA #0 278
03/10/2021
7hsdoaanwthssbww e'ecVcWc*0anW
ewd walwd U" d pigibq sign mn' f ntad
coplesvAthrnd�x7'm1�nd�gnatiawrt be
w°iflwd �fngt�w ori�n vwwon.
Alpine, an ITW Company
6750 Forum Drive, Suite 305
Orlando, FL 32821
Phone: (800)755-6001
www.alpineitw:com
S�te:lraformai`rQn 3 � �
Pa s i
Customer Carpenter Contractors of America
Job Number: N333978
Job Description: 7A5/320 ,167EC ,RJO1 / 1672/ARIA/4EAB ELEV.0
Address:
JlatiE` ineerin
Design Code: FBC 7th Ed. 2020 Res lntelliV/EW Version. 20.02.00A
JRef#: lX3L89750074
Wind Standard: ASCE 7-16 Wind Speed (mph): 160 Design Loading (psi): 37.00
Building Type: Closed
This package contains general notes pages, 22 truss drawing(s) and 4 detail(s):
1
069.21.1302.25093
Al
3
069.21.1302.25249
A2
5
069.21.1302.25202
A4
7
069.21.1302.25297
A6
9
069.21.1302.25186
A8G
11
069.21.1302. 24999
131.
13
069:21.1302.24593
C1 GE
15
069.21.1302.24655
MV2
17
069.21.1302.25061
ER
19
069.21.1302.24905
CJ5
21
069.21.1302.24718
CJ1
23
A16015ENC160118
25
VAL180160118
2
069.21.1`302.24906
A1A
4
069.21.1302.25155
A3
6
06921.1302.25171
A5
8
069.21.1302.24859'
A7
10
069.21.1302.24812
A9G
12
069.21.1302.24640
132GE
14
069.21.1302.25250'
MV1
16
069 21.1302,24452
V1
18
069.21.1302.24765
EJ7A
20
069.21.1302.24858
CJ3
22
069.21.1302.21734
HJ7
24
GBLLETIN0118
26
VALTN160118
Florida Certificate of Product Approval #FL1999 Printed 3/10/2021 1:54 29 PM
General Notes
Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities:
The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1,
Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate
Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design
Specification for Wood Construction by AWC. The truss component designs are based on the specified loading and
dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to
independently verify the accuracy or completeness of the information provided by others and may rely on that information
without liability. The responsibility for verification of that information remains with others neither employed nor controlled
by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page
listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component
designs and not for the technical information furnished by others which technical information and consequences thereof
remain their sole responsibility.
The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in
accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and
loads for each truss component match those required by the plans and by the actual use of the individual component, and
for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any
additional factors required in the particular application. Truss components using metal connector plates with integral teeth
shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to
exceed 19% and/or cause corrosion of connector plates and other metal fasteners.
The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set
forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss
component design loads, inspection of the truss components before or after installation, the design of temporary or
permanent bracing and their attachment required in the roof and/or floor systems, the design of diaphragms or shear
walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the
foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports,
installation of the truss components, observation of the truss component installation process, review of truss assembly
procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in
the installation of the truss components and/or its connections.
This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic
file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request.
Temporary Lateral Restraint and Bracing:
Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2,
B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or
other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these
drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to
and may not be relied upon for the temporary stability of the truss components during their installation.
Permanent Lateral Restraint and Bracing:
The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of
the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of
BCSI chapters B3, B7 and/or 1310, or as specified by the Building Designer or other Registered Design Professional.
These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building
stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building
Designer.
Connector Plate Information:
Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations,
gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60.
Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at
www. icc-es. ora.
Fire Retardant Treated Lumber:
Fire retardant treated lumber must be properly re -dried and maintained below 19% or less moisture level through all
stages of construction and usage. Fire retardant treated lumber may be more brittle than untreated lumber. Special
handling care must be taken to prevent breakage during all handling activities.
Page 1 of 3
General Notes (continued)
Key to Terms:
Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed
information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be
found in calculation sheets available upon written request.
BCDL = Bottom Chord standard design Dead Load in pounds per square foot.
BCLL = Bottom Chord standard design Live Load in pounds per square foot.
CL = Certified lumber.
Des Ld = total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot.
FRT = Fire Retardant Treated lumber.
FRT-DB = D-Blaze Fire Retardant Treated lumber.
FRT-DC = Dricon Fire Retardant Treated lumber.
FRT-FP = FirePRO Fire Retardant Treated lumber.
FRT-FL = FlamePRO Fire Retardant Treated lumber.
FRT-FT = FlameTech Fire Retardant Treated lumber.
FRT-PG = PYRO-GUARD Fire Retardant Treated lumber.
g = green lumber.
HORZ(LL) = maximum Horizontal panel point deflection due to Live Load, in inches.
HORZ(TL) = maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep
adjustment.
HPL = additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds.
Ic = Incised lumber.
FJ = Finger Jointed lumber.
L/# = user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value.
L/defl = ratio of Length between bearings, in inches, divided by the vertical Deflection due to creep, in inches, at the
referenced panel point. Reported as 999 if greater than or equal to 999.
Loc = Location, starting location of left end of bearing or panel point (joint) location of deflection.
Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases.
Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases.
Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases.
NCBCLL = Non -Concurrent Bottom Chord design Live Load in pounds per square foot.
PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds.
PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds
PLT = additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds.
PP = Panel Point.
R = maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc).
-R = maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc).
Rh = maximum horizontal design Reaction in either direction, in pounds, from all specified gravity load cases, at the
indicated location (Loc).
RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non -gravity (wind or seismic)
load cases, at the indicated location (Loc).
Rw = maximum downward design Reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the
identified location (Loc).
TCDL = Top Chord standard design Dead Load in pounds per square foot.
TCLL = Top Chord standard design Live Load in pounds per square foot.
U = maximum Upward design reaction, in pounds, from all specified non -gravity (wind or seismic) load cases, at the
indicated location (Loc).
VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in
inches.
VERT(CTL) = maximum Vertical panel point deflection ratios due to Live Load and Creep Component of Dead Load, and
maximum long term Vertical panel point deflection in inches due to Total load, including creep adjustment.
VERT(LL) = maximum Vertical panel point deflection in inches due to Live Load.
VERT(TL) = maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment.
W = Width of non -hanger bearing, in inches.
Refer to ASCE-7 for Wind and Seismic abbreviations.
Uppercase Acronyms not explained above are as defined in TPI 1.
Page 2 of 3
References:
1. AWC: American Wood Council; 222 Catoctin Circle SE, Suite 201; Leesburg, VA 20175; www.awc.org.
2. ICC: International Code Council; www.iccsafe.or4.
3. Alpine, a division of ITW Building Components Group Inc.: 514 Earth City Expressway, Suite 242, Earth City, MO
63045; www.alpineitw.com.
4. TPI: Truss Plate Institute, 2670 Crain Highway, Suite 203, Waldorf, MD 20601; www.tpinst.orq.
5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719; www.sbcindustry.com.
Page 3 of 3
SEQN: 496491 COMN Ply: 1 Job Number: N333978 I Cust: R 8975 JRef:1X3L89750074 T18 /
FROM: RWM Qty: 8 7A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.25093
Truss Label: Al SSB / YK 03/10/2021
6'1"7 i 12'815 19'4'
6'1"7 6'7"8 67"1
i 1100'
'
Loading Criteria (psi)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 3.87 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #1;
Webs: 2x4 SP #3; W3,W4,W5 2x4 SP #2 N;
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint to
be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2) scabs
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web
member. Attach with 0.128x3" gun nails @ 6" oc.
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
=5X5
E
38'8"
9,4"
19'4"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
03/10/2021
25'11"1 32'6"9 38'8"
6'T'1 6'7"S 6'1'7
9,4„
28'8"
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.208 K 999 360
VERT(CL): 0.361 K 999 240
HORZ(LL): 0.076 J - -
HORZ(TL): 0.131 J
Creep Factor: 2.0
Max TC CSI: 0.531
Max BC CSI: 0.793
Max Web CSI: 0.428
VIEW Ver: 20.02.00A.1020.20
10, 1'
38'8"�
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1660 /- /- /936 /301 /432
H 1660 /- /- /936 /301 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 2.0
H Brg Width = 8.0 Min Req = 2.0
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1446 - 3039 E - F 1102 -1959
C - D 1324 - 2761 F - G 1324 - 2761
D - E 1102 -1959 G - H 1446 - 3039
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - L 2656 -1166 K - J 2199 - 829
L - K 2199 - 848 J - H 2656 -1147
Maximum Web Forces Per Ply (Ibs)
Webs
Tens.Comp. Webs Tens. Comp.
L - D
520 -130 K - F 512 - 724
D - K
512 - 724 F - J 520 -130
E - K
1316 - 593
**WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSL Unless noted otherwise, top chord shall have properPy attached structural sheathing and bottom chord shali have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicabgle. Apply plates to each face, of truss and position as shown above and on the Joinl9Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the ANRWCOMPANY
truss in conformance with ANSIf� PI 1, or for handling, shipping,, installation and bracin44 of trusses. A seal on this drawing or cover pa a 675o Forum Drive
listing this drawing indicates acceptance of professional engsneering responsibility solely for the design shown. The suitability and use of This
drawing for any s9r'ucture is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.org; SBCA: sbcindustrv.com: ICC: !ccsafe.ora: AWC: awc.ora - Orlando FL, 32821
SEQN: 49650! COMN Ply: 1 Job Number: N333978 TD-N,
R8975 JRef:1X3L89750074 T23 /
FROM: PFH Qty: 1 ,7A5/320 ,167EC ,RJ01 ! 1672/ARlk4EAB ELEV.0 o: 069.21.1302.24906
Truss Label: A1A / DF 03110/2021
2112
92
7'10"14 12'1"12 17'1111 19' ' 26'6"4 i 30'9"2 38'8"
T10'14 42'14 5'e'842'14 + T1094
—5F5
T
1 �
E �
T2 '�4X4
g4X4 T3
12 D H
6 17 w9
g5X5 ' 56r5
c
R N
B
A + K 8'8"
=4X6(A2) U =5x14 =5X8 cP =6X8 =5x14 L-4X6(A2)
38'8"
F7'_T 711"5 4'0"11 5'10"4 17"10 5'8" 4'0"11 Tit"5 +1�
T11"5 12' 1T10"4 19'S 14 2fi'8" r 30'8"11 388"
21'
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
Des Ld: 37.00
EXP: C Kzt: NA
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 3.87 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1; T2,T3 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3; W6,W9 2x4 SP #2 N;
Plating Notes
All plates are 2X4 except as noted.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
+ Bottom Chord section between vertcials may
be removed.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc L/defl L!#
VERT(LL): 0.201 E 999 360
VERT(CL): 0.375 E 999 240
HORZ(LL): 0.100 L - -
HORZ(TL): 0.186 L
Creep Factor: 2.0
Max TC CSI: 0.739
Max BC CSI: 0.793
Max Web CSI: 0.865
VIEW Ver: 20.02.00A.1020.20
♦Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1518 /- /- /936 /301 /432
J 1518 /- /- /936 /301 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 2.1
J Brg Width = 8.0 Min Req = 2.1
Bearings B & J are a rigid surface.
Bearings B & J require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1366 - 2665 F - G 1495 - 2370
C - D 1312 - 2278 G - H 1355 - 2399
D - E 1328 - 2355 H - I 1311 - 2276
E - F 1493 - 2326 I - J 1366 - 2665
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp
B - U 2299 -1067 M - L 2298 -1049
U - T 2297 -1068 L - J 2300 -1048
R - N 1841 - 595
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp
C - T 315 - 446 F - N 1047 - 722
T - R 2100 - 905 N - M 2114 - 888
E - R 387 - 251 M -1 319 - 451
R - F 1050 - 747
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper) attached structural sheathing and bottom chord shall have a properly
attached r! id ceilin Locations shown for ermanent lateral restraint olYwebs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicaboe. Applgy plates to each face oTtruss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Building Components Group Inc. shall not.be responsible for any deviation from this drawing, any failure to build the ANMCOWAW
truss in conformance with ANSIITPI-1, or for handling, shipping,, installation and bracin4of trusses. A seal on this drawing or cover pa a 675o Forum Drive
listing this drawingp indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of this
drawing for any sFructure is the responsibility of the Building esigner per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 49651 / SPEC Ply: 1 Job Number: N333978 Cust: R8975 JRef:1X3L89750074 T17 /
FROM: RWM Qty: 2 , A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.25249
Truss Label: A2 �SSB / DF 03/10/2021
6'1"7 12'8"15
6'1"7 6'7"8 6'3"1
10,
10'
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 3.87 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #1;
Webs: 2x4 SP #3; W3,W4,W5 2x4 SP #2 N
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint to
be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2) scabs
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web
member. Attach with 0.128x3" gun nails @ 6" oc.
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
25'11"138'8"
6'1 V1 6'7"8 617
5X5
E
38'8"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
18,8"
28'8"
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.208 K 999 360
VERT(CL): 0.361 K 999 240
HORZ(LL): 0.076 J - -
HORZ(TL): 0.131 J
Creep Factor: 2.0
Max TC CSI: 0.531
Max BC CSI: 0.793
Max Web CSI: 0.427
Ver: 20.02.00A.1020.20
4 R
° Savo+
En
10, 1'
38'8"��
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 1660 /- /- /936 /292 /427
H 1660 /- A /936 /292 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 2.0
H Brg Width = 8.0 Min Req = 2.0
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - C 1415 - 3039 E - F 1069 -1960
C - D 1292 - 2761 F - G 1292 - 2761
D - E 1070 -1960 G - H 1415 - 3039
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - L 2656 -1142 K J 2199 - 804
L - K 2199 - 824 J- H 2656 -1121
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
L - D 520 -130 E - K 1314 - 596
D-K 517 -723 F-J 520 -131
K - F 518 - 723
STATE F
#gym
0 0®6
COA #
03/10/2021
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and'SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have roperlr attached structural sheathing and bottom chord shall have a properly
attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. App�y plates to each face oT truss and position as shown above and on the Join, Details, unless noted otherwise. Defer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinIc�Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the MN COWAW
truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation. and bracin of trusses. A seal on this drawin or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional en ineenng responsibilittvy solely or the design shown. The suitability and use of This
drawing for any structure is the responsibility of the BuildingUesigner per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.or Orlando FL, 32821
SEQN: 49652 / HIPS Ply: 1 Job Number: N333978 Cust: R 8975 JRef:1X3L89750074 T16 /
FROM: RWM Qty: 2 7A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.25155
Truss Label: A3 SSB / OF 03/10/2021
T1014 1T 21'8" 30'9"2
T10"14 T 9'1"2 i' 4'S" 9'1"2
r�
b
co
1' 10'
i 10, '}
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
Spacing: 24.0 "
C&C Dist a: 3.87 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N; T2,T4 2x4 SP 2400f-2.OE;
Bot chord: 2x4 SP #1; B2,B3 2x4 SP 2400f-2.0E;
Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3;
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint to
be equally spaced. Attach with (2) 8d Box or Gun
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
restraint. substitute (1) scab for (1) CLR and (2) scabs
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web
member. Attach with 0.128x3" gun nails @ 6" oc.
Loading
Truss passed check for 20 psf additional bottom chord
live load in areas with 42"-high x 24"-wide clearance.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
=5X5 =5X5
D E
38'8"
9,4„
19'4"
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT;20(0)/l 0(0)
Plate Type(s):
r
ri
38'8"
7'10"14
94
28'8"
10 11
38'8"
Deft/CSI Criteria
♦ Maximum Reactions (Ibs)
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
VERT(LL): 0.183 J 999 360
Loc R+ / R- / Rh / Rw / U / RL
VERT(CL): 0.309 J 999 240
B 1716 /- !- /940 /309 /385
HORZ(LL): 0.068 1 - -
G 1716 /- !- /940 1309 /-
HORZ(TL): 0.116 1
Wind reactions based on MWFRS
Creep Factor: 2.0
B Brg Width = 8.0 Min Req = 2.0
Max TC CSI: 0.759
G Brg Width = 8.0 Min Req = 2.0
Max BC CSI: 0.739
Bearings B & G are a rigid surface.
Max Web CSI: 0.592
Bearings B & G require a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
VIEW Ver: 20.02.00A.1020.20
B - C 1592 - 3121 E - F 1617 - 2927
C - D 1617 - 2927 F - G 1593 - 3121
D - E 1280 - 2045
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp. Chords Tens. Comp.
B - K 2718 -1300 J - 1 1979 - 765
K - J 1979 - 785 I - G 2718 -1280
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
C - K 501 - 443 E - 1 837 - 441
K - D 837 - 441 I - F 501 - 443
a n pf
��.+sapoa
Fri
03/10/2021
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing er BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly
attache.yr! id ceilin Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, _
as applicabgle. App�y Oates to each face oT truss and position as shown above and on the Joint Details, unless noted otherwise. Defer to ALPINE�
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildingq�Components Group Inc. shall not be res ronsible for any deviation from this drawing, any failure to build the ANI COMPANY
truss in conformance with ANSI/TPI 1, or for handling, shipping,, installs ion and bracin of trusses. A seal on this drawing or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engineering tesponsibilit� solely ,for the design shown. The suitability and use of This
drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: alpineihv.com; TPI: tpinst:orq; SBCA: sbcindustrv.com: ICC: iccsafe.orq: AWC: awc.oro Orlando FL, 32821
SEON: 49653 / HIPS
Ply: 1
Job Number: N333978
Cust: R 8975 JRef:1X3L89750074 T15 !
FROM: RWM
Qty. 2
7A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0
DrwNo: 069.21.1302.25202
Truss Label: A4
SSB / DF 03/10/2021
7'10"14 15' 23'8" 30'9"2
38'8"
7'1014 7'1 "2 8'8" 7'1 "2
7'10"14
5X5 5X5
D T3 E
12
6 ,5X5
5X5
C
r
0
W ao
W1
B
A
G
4_3
H8'8"
-4X6(A2) -1-1
6X6 B2 -6X6 B3 =6X6=4X6(A2)
38'8"
10' 9'4" 9'4"
10,
10' 19W 28'8"
38'8"
Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U#
Gravity Non -Gravity
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.194 J 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.333 J 999 240
B 1694 /- /- /938 /319 /344
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.068 1 - -
G 1694 /- /- /938 /319 A
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.116 1 -
Wind reactions based on MWFRS
NCBCLL: 10.00 Building Code: Creep Factor: 2.0
TCDL: 4.0 psf
B Brg Width = 8.0 Min Req = 2.0
Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.939
G Br Width = 8.0 Min Re = 2.0
g q —
Load Duration: 1.25 MWFRS Parallel Dist: h to 2h TPI Std: 2014 Max BC CSI: 0.744
Bearings B & G are a rigid surface.
Bearings B & G require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Fac: Yes Max Web CSI: 0.496
Members not listed have forces less than 375#
Loc. from endwadwall: not in 9.00 ft FT/RT:20(0)/10(0)
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20
Lumber
B - C 1729 -3051 E - F 1748 -2859
Top chord: 2x4 SP #2 N; T3 2x4 SP #1;
C - D 1748 - 2859 F - G 1729 - 3051
D - E 1464 -2203
Bot chord: 2x4 SP #1; 132,133 2x4 SP 2400f-2.0E;
Webs: 2x4 SP #2 N; W1,W6 2x4 SP #3;
Maximum Bot Chord Forces Per Ply (Ibs)
Loading
Chords Tens.Comp. Chords Tens. Comp.
Truss passed check for 20 psf additional bottom chord
B - K 2649 -1413 J - 1 2086 -1029
live load in areas with 42"-high x 24"-wide clearance.
K - J 2086 -1048 I - G 2649 -1393
Wind
Wind loads based on MWFRS with additional C&C
Maximum Web Forces Per Ply (Ibs)
member design,
Webs Tens.Comp. Webs Tens. Comp.
Wind loading based on both gable and hip roof types.
C - K 405 -360 E - 1 712 -314
K - D 712 - 314 I - F 405 -360
'AS Ft
E��b�Q
0
a
�a
o. 648
m �
e
F
COA #0 NAL
03/10/2021
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide
BCSI (Building
temporary
_
bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. App7gy plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise.
Refer
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
ALPINE
Alpine, a division of ITW Building Components Group Inc. shall not be responsible for any deviation from this drawing, any failure
truss in conformance ANSI/TPI 1, for handling,
to build the - — ANT4cO--
with or shipping,, installation and bracin of trusses. A seal on this drawing
listing this drawing indicates acceptance of professional en sneering responsibility solely or the design shown. The suitability
drawing for any structure is the responsibility of the BuildingUesigner perANSIITPI 1 Sec.2.
or cover page 6750 Forum Drive -
and use of this
Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: icosafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 496541 HIPS
Ply: 1
Job Number: N333978
R8975 JRef:1X3LB9750074 T14 /
FROM: RWM
Qty: 2
7A5/320 ,167EC ,RJ01 / 1672/ARIAI4EAB ELEV.0
rD-No:069.21.1302.25171
Truss Label: A5
/ OF 03/10/2021
6'9"4 13' 19'4" 25'8"
31'10"12 38'8"
6'94 6'2"12 6'4" 6'4"
6'2"12 6'9"4
=5X5 1112X4 =5X5
D E F
12
6 2X4
m W3
ZW
2012C
B
H
A
4X6(A2) =6X6 =5X8 =6X6=4X6(A2)
i_
� 38'8"
10' 9'4" 9'4"
10,
10' 19A 28'8"
38'8"
Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pfin P6F) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U#
Gravity Non -Gravity
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.220 E 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.382 E 999 240
B 1665 /- /- /931 /699 /303
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.075 J - -
H 1665 /- /- /931 /699 /-
EXP: C Kzt: NA
Des Ld: 37.00 HORZ(TL): 0.130 J - -
Wind reactions based on MWFRS
Mean Height: 15.00 ft
NCBCLL: 10.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0
4.2
B Br Width = 8.0 Min Re 2.0
9 q =
Soffit: 0.00 BCDL: psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.535
H Brg Width = 8.0 Min Req = 2.0
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.797
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Fac: Yes Max Web CSI: 0.565
Members not listed have forces less than 375#
Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0)
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20
Lumber
B - C 1934 -3031 E - F 1860 -2498
C - D 1844 - 2775 F - G 1844 - 2775
Top chord: 2x4 SP #2 N;
D - E 1860 - 2498 G - H 1934 - 3031
Bot chord: 2x4 SP #1;
Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N;
Maximum Bot Chord Forces Per Ply (Ibs)
Loading
Chords Tens.Comp. Chords Tens. Comp.
Truss passed check for 20 psf additional bottom chord
B - L 2643 -1613 K - J 2172 -1247
live load in areas with 42"-high x 24"-wide clearance.
L - K 2172 -1267 J - H 2643 -1594
Wind
Wind loads based on MWFRS with additional C&C
Maximum Web Forces Per Ply (Ibs)
member design.
Webs Tens.Comp. Webs Tens. Comp.
Wind loading based on both gable and hip roof types.
C - L 385 - 333 K - F 470 - 357
tumilpizt4w
L - D 573 -188 F - J 573 -188
�*
a3 ice'
D - K - 357 J - G 385 333
E - K 536 536 - 353
efpCO ®&OECga� � B�
e
a
No. 64
c
a
ATE OF �•° ��
COA #
03/10/2021
'"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installingand bracing. Refer to and follow the latest edition
Component Safety Information, by TPI for
of BCSI (Building
and SBCA) safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face, of truss and position as shown above and on the Joint -Details, unless noted otherwise.
Refer to
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
ALPINE
Alpine, a division of ITW Buildin Components Group Inc. shall not be responsible for any deviation from this drawing,.any failure to build the ANR COMPANY
truss -in conformance ANSI PI 1, for handling,
with or shipping,, installation and bracinclof trusses. A seal on this drawin or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engineering responsibility solely for the design shown. The suitability and use of this
drawing for any structure is the the Building -Designer Suite 305
responsibility of perANSVT�l 1 Sec.2.
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: Iccsafe.of ; AWC: awc.org Orlando FL, 32821
SEQN: 49655 / HIPS
Ply: 1
Job Number: N333978
Cust: R 8975 JRef:1X31-89750074 T12 /
FROM: RWM
Qty: 2
7A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0
DrwNo: 069.21.1302.25297
Truss Label: A6
SSB / OF 03110/2021
59"4 11' 19, 27'8"
32'10"12 38'8"
5'9"4 12 8' 8'8"
5'2"12 5'9"4
.5X5 =5X5 =5X5
D E T3 F
T 12
6 � • 2X4 W
C
2X4
b (a) (a)
C' u�
n W3
ih
io
1 B
H
A
�
1 �8'8"
L K J
4X6(A2) =5X5 =5X8 =5X5
=4X6(A2)
38'8"
10' 9'4" 9'4"
10,
10' 19'4" 28'8"
38'8"
Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U#
Gravity Non -Gravity
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.236 E 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.417 E 999 240
B 1627 A /_ /918 /701 /263
BCDL: 10.00 Risk Category: 11 Snow Duration: NA HORZ(LL): 0.074 J - -
H 1627 A /- /918 1701 A
EXP: C Kzt: NA
Des Ld: 37.00 HORZ(TL): 0.131 J
Wind reactions based on MWFRS
Mean Height: 15.00 ft
NCBCLL: 10.00 Building Code: Creep Factor: 2.0
TCDL: psf
B Brg Width = 8.0 Min Req = 1.9
Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.832
5.0
H Br Width = 8.0 Min Re 1.9
g q =
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.731
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Fac: Yes Max Web CSI: 0.575
Members not listed have forces less than 375#
Loc. from endwall: not in 9.00 ft FT/RT:20(0)/10(0)
Maximum Top Chord Forces Per Ply (Ibs)
GCp!: 0.18 Plate Type(s):
Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20
Lumber
B - C 2112 -2963 E - F 2286 -2820
C - D 1978 - 2697 F - G 1982 - 2700
Top chord: 2x4 SP #2 N; T3 2x4 SP #1;
D - E 2329 -2850 G - H 2108 -2960
Bot chord: 2x4 SP #1;
Webs: 2x4 SP #3; W3,W5 2x4 SP #2 N;
Maximum Bot Chord Forces Per Ply (Ibs)
Bracing
Chords Tens.Comp. Chords Tens. Comp.
(a) 1X4 #3SRB or better continuous lateral restraint to
B - L 2588 -1780 K - J 2288 -1495
be equally spaced. Attach with (2) 8d Box or Gun
L - K 2282 -1505 J - H 2585 -1756
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor.
Maximum Web Forces Per Ply (Ibs)
(a) or scab reinforcement may be used in lieu of CLR
Webs Tens.Comp. Webs Tens. Comp.
restraint. substitute (1) scab for (1) CLR and (2) scabs
L - D 462 -70 K - F 639 - 598
for (2) CLR'S where shown. Scab reinforcement to be
D - K 682 -662 F - J 461 -62
same size, species, grade, and 80% length of web &p
member. Attach with 0.128x3" gun nails @ 6" oc. +
E - K 734 -495
Loading
Truss passed check for 20 psf additional bottom chord oapy
ova
live load in areas with 42"-high x 24"-wide clearance.
a
a
Wind s No. 8 o
Wind loads based on MWFRS with additional C&C a
member design. a c
Wind loading based on both gable and hip roof types. e
as
®$�
6
FDA+amfemr as a
COA # AWL
03/10/2021
**WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, b TPI SBCA) for
and safety practices prior to performing these functions. Installers shall provide
bracing per BCSI. Unless noted oytherwise, top chord shall have properattached structural sheathing and bottom chord shall
temporary
have a properly
attache U rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face, otruss and position as shown above and on the Join Details, unless noted otherwise. Refer to
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
ALPINE
Alpine, a division of ITW BuildinlgComponents Group Inc. shall not, be responsible for any deviation from this drawing, any failure
truss in conformance with ANSI/TPI 1,- or for handling, shipping,, installation and bracin trusses. A this drawin
to build the ANMCOMPAW
of seal on
listing this drawing indicates acceptance of professional engineering responsibili(� solely -for the design shown. The suitabilify
drawing for any structure is the responsibility of the Building Designer per ANSVTPI 1 Sec.2.
or cover pa a 675o Forum Drive
and use of Phis
Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEON: 49656 / HIPS
Ply: 1
Job Number: N333978
Cust: R 8975 JRef:1X3L89750074 T11 !
FROM: RWM
Qty: 2
7A5/320 ,167EC ,RJ01 / 1672lARIAl4EAB ELEV.0
DnwNo: 069.21.1302.24859
Truss Label: A7
SSB / WHK 03/10/2021
9' 17' 21'8" 29'8"
9' 8' 4'8" 8, 9'
6X6 =5X5 =4X4 =6X6
C T2 D E T3 F
12
6
T
o (a) W (a) m
a W5 i7
to
B G
A
a_•3
=4X6(A2) =6X6 =5X5 =6X6=4X6(A2)
38'8"
�1' 10, 9'4" 9'4" 10, 1
10' 19'4" 28'8" 38'8"
Loading Criteria (psf) Wind Criteria - Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria ♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection ink loc Udefl U# Gravity Non -Gravity
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.229 J 999 360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.427 J 999 240 B 1518 /- /- /900 /703 /222
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.075 1 - - G 1518 /- /- /900 f703 /-
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.140 I Wind reactions based on MWFRS
NCBCLL: 10.00 Building Code: Creep Factor: 2.0 B Brg Width = 8.0 Min Req = 1.8
TCDL: 4.2 psf
G Br Width = 8.0 Min Re 1.8
Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.906 g q =
Load Duration: 1.25 MWFRS Parallel Dist: h/2 to h TPI Std: 2014 Max BC CSI: 0.794 Bearings B & G are a rigid surface.
Bearings B & G require a seat plate.
Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Fac: Yes Max Web CSI: 0.280
Members not listed have forces less than 375#20(0)/10(0)
Loc. from endwall: not in 9.00 ft FT/RT;
Maximum Top Chord Forces Per Ply (Ibs)
GCpi: 0.18 Plate Type(s): Chords Tens.Comp. Chords Tens. Comp.
Wind Duration: 1,60 WAVE VIEW Ver: 20.02.00A.1020.20
Lumber B - C 2172 - 2622 E - F 2160 - 2395
C - D 2160 -2395 F - G 2172 -2621
Top chord: 2x4 SP #1; T2,T3 2x4 SP #2 N; D - E 2774 -3079
Bot chord: 2x4 SP #1;
Webs: 2x4 SP #3; W2,W5 2x4 SP #2 N;
Maximum Bot Chord Forces Per Ply (Ibs)
Bracing Chords Tens.Comp. Chords Tens. Comp.
(a) 1 X4 #3SRB or better continuous lateral restraint to B - K 2256 -1787 J - 1 3036 - 2492
be equally spaced. Attach with (2) 8d Box or Gun K - J 3034 -2506 1 - G 2256 -1766
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
erection contractor. Maximum Web Forces Per Ply (Ibs)
(a) or scab reinforcement may be used in lieu of CLR Webs Tens.Comp. Webs Tens. Comp.
restraint. substitute (1) scab for (1) CLR and (2) scabs C - K 687 -389 E - I 869 -765
for (2) CLR'S where shown. Scab reinforcement to be K - D 866 -763 I - F 688 391
same size, species, grade, and 80% length of web
member. Attach with 0.128x3" gun nails @ 6" oc. p
Wind
+� �r
Wind loads based on MWFRS with additional C&C
member design. A
Wind loading based on both gable and hip roof types. 0
o. s
a
m
-sA E OF cc
A
W
OR
a
aute
CIDA
03/10/2021
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r to these functions. Installers
safety practices prior performing shall provide temporary
bracing per BCSL Unless noted otherwise, top chord shall have propery attached structural sheathing and bottom chord shall have a properly
attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. App�y pplates to each face. of truss and position as shown above and on the Join f Details, unless noted otherwise. Defer to
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
ALPINE
Alpine, a division of ITW BuildinQcLComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the A CCMPAW
truss in conformance with ANSI/TPI 1, or for handling, shipping,. installation bracin trusses. A this drawin
and of seal on or cover pa a 6750 Forum Drive
listing this drawin indicates acceptance of professional engineering responsibili�v solely -for the design shown. The suitabilify and use of this
drawing for
any sfructure is the responsibility of the Building Designer per ANSI/41 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineilw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEON: 49669! SPEC
Ply: 1
Job Number: N333978
Cust: R 6975 JRei:1X3L89750074 T3 !
FROM: RDP
Oty: 1
7A5/320 ,167EC ,RJ01 / 1672lARIAl4EAB ELEV.0
DrwNo: 069.21.1302.25186
Truss Label: ABG
SSB / DF 03/10/2021
7' 12'4" 21' 26'1"12
3138'8"
7' S'4" 8'8" 5'1"12
5'64 7'
,5X5 =4X4 =SS0712 =4X4
=5X5
12 C D T2 E F T3
G
T 6�
(a) W
i+r
B
H v
1 T5 A
I I 8,8.,
81
=4X6(A2) =H0710 82 =8X8 1113X6L 4X4
=5X5=3X6(A1) 1
21' 5'
12'8"
8'8" 4'4" 4'10"4 4'9"12 8'
8' 16'8" 21' 25'104 308" 38'8"
Loading Criteria (psi) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Sid: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Lldefl L!#
Gravity Non -Gravity
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.086 N 999 360
Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.161 N 999 240
B 1674 /- /- /- /829 /-
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.021 M - -
L 2709 /- /- /- /1293 /-
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 15.00 ft HORZ(TL): 0.040 M - -
K 504 /- /- /- /204 /-
NCBCLL: 10.00 Building Code: Creep Factor: 2.0
TCDL: psf
H 386 /- /- P /177 /-
.2
Soffit: 0.00 gCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TC CSI: 0.924
Wind reactions based on MWFRS
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.725
B Brg Width = 8.0 Min Req = 1.5
L Brg Width = 8.0 Min Req = 3.8
Re Fac: Varies b Ld Case Max Web CSI: 0.724
Spacing: 24.0 " C&C Dist a: 3.87 ft p y
K Brg Width = 8.0 Min Req = 1.5
Loc. from endwall: not in 4.50 ft FT/RT:20(0)/10(0)
H Brg Width = 8.0 Min Req = 1.5
GCpi: 0.18 Plate Type(s):
Bearings B, L, K. & H are a rigid surface.
Wind Duration: 1.60 WAVE HS 18SS VIEW Ver: 20.02.00A.1020.20
Bearings B, L, K, & H require a seat plate.
Lumber Wind
Members not listed have forces less than 375#
Top chord: 2x4 SP #2 N; T2,T3 2x4 SP 2400f-2.OE; Wind loads and reactions based on MWFRS.
Maximum Top Chord Forces Per Ply (Ibs)
Bot chord: 2x4 SP #2 N; B1 2x4 SP 2400f-2.OE; Wind loading based on both gable and hip roof types.
Chords Tens.Comp. Chords Tens. Comp.
B2 2x6 SP SS;
Webs: 2x4 SP #3; W4 2x4 SP #2 N;
B - C 1495 -2998 D - E 399 -1036
C - D 1336 -2840 E - F 638 -335
Bracing
(a) 1X4 #3SRB or better continuous lateral restraint to
Maximum Bot Chord Forces Per Ply (Ibs)
be equally spaced. Attach with (2) 8d Box or Gun
Chords Tens.Comp. Chords Tens. Comp.
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
B - N 2612 -1278 L - K 463 959
erection contractor.
N - M 2485 -1375 K - J 306 - 584
(a) or scab reinforcement may be used in lieu of CLR
M - L 463 - 960
restraint. substitute (1) scab for (1) CLR and (2) scabs
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp. Webs Tens. Comp.
member. Attach with 0.128x3" gun nails @ 6" cc. S0
C - N 857 - 214 E - L 1325 - 2526
Special Loads p;S+m %
N - D 462 0 E - K 437 -158
+� o,
( o + +
Lumber Dur.Fac.=1.25 /Plate Dur.Fac.=1.25) • ®
D - M 1257 -1872 K - F 356 - 665
TC: From 56 plf at -1.00 to 56 plf at 7.00 n
M - E 2560 -1110 F - J 806 - 357
TC: From 28 plf at 7.00 to 28 plf at 21.00 ¢®
TC: From 56 plf at 21.00 to 56 plf at 39.67 No. 648
a
BC: From 20 plf at 0.00 to 20 at 7.03
plf
e
BC: From 10 plf at 7.03 to 10 plf at 19.06 e
BC: From 20 plf at 19.06 to 20 plf at 38.67 •
TC: 214 lb Conc. Load at 7.03 TC: 174 lb Conc. Load at 7.06, 9.06,11.06,13.06 O
15.06,17.06®
TC: 177 lb Conc. Load at 19.06 ' o�
BC: 489 lb Conc. Load at 7.03 agrremPnmay�
BC: 125 lb Conc. Load at 9.06,11.06,13.06,15.06
17.06,19.06 !
COA #0 a*
03/10/2021
**WARNING- READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handling shipping, installing and bracing. Refer to and follow the latest edition
Component Safety Information,
of BCSI (Building
by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properattached structural sheathing and bottom chord shall have a properly
attacheU rigid ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10
as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise.
Refer to
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
ALPINE
Alpine, a division of ITW Buildin Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure
truss in ANSI/ PI for
to build the nr�rt COWAW
conformance with 1, or handling, shipping,, installation and bracin44of trusses. A seal on this drawin or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional en ineering responsibility solely -for the design shown. The suitabilil9y and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.orn Orlando FL, 32821
SEQN: 49670! HIPS
Ply: 1
Job Number: N333978
Cust: R8975 JRef:1X31_39750074 T22 /
FROM: RDP
Qty: 1
7A5/320 ,167EC ,RJ01 / 1672/ARIAI4EAB ELEV.0
DrwNo: 069.21.1302.24812
Truss Label: A913 _
_
SSB / FV 03/10/2021
7' 17' 1 26'4"
31'8" 38'8"
7' 10, 9'4"
5'4" 7'
=6X12
12 111 C8 T2 =8XD10 TE
=6F6
T 6�
T
o (a) W
o
N��
(a)
fh
B
A
t7
G
1 4�
H
4X6(A2) B1 1112X4 =5X5 1112X4 =6X8 1115X5J
=5X5 =3X6(A1)
26'4"
12'4„
7'1"12 4'10"4 5' 5'8" 38"
5'0"8 738 V"
7'1"12 12' 17' 22'8" 26'4"
31'4"8 38'8"
Loading Criteria (psf) Wind Criteria Snow Criteria (Pg,Pf in PSF) Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00 Wind Std: ASCE 7-16 Pg: NA Ct: NA CAT: NA PP Deflection in loc Udefl U#
Gravity Non -Gravity
TCDL: 7.00 Speed: 160 mph Pf: NA Ce: NA VERT(LL): 0.147 M 999 360
Loc R+ / R- / Rh / Rw / U ! RL
BCLL: 0.00 Enclosure: Closed Lu: NA Cs: NA VERT(CL): 0.277 M 999 240
B 1749 /- /- /- /804 /-
BCDL: 10.00 Risk Category: II Snow Duration: NA HORZ(LL): 0.053 K - -
J 4106 A /- /- /1847 /-
EXP: C Kzt: NA
Des Ld: 37.00 Mean Height: 10.51 ft HORZ(TL): 0.101 K - -
G 252 /- /- /- /131
NCBCLL: 0.00 TCDL: 4.2 psf Building Code: Creep Factor: 2.0
Wind reactions based on MWFRS
Soffit: 0.00 BCDL: 5.0 psf FBC 7th Ed. 2020 Res. Max TIC CSI: 0.788
B Brg Width = 8.0 Min Req = 2.1
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2 TPI Std: 2014 Max BC CSI: 0.975
J Brg Width = 8.0 Min Req = 5.7
G Brg Width = 8.0 Min Req = 1.5Bearings
Spacing: 24.0 " C&C Dist a: 3.87 ft Rep Fac: No Max Web CSI: 0.866
B, J. & G are a rigid surface.
Loc. from endwal!: NA FT/RT:20(0)/10(0)
Bearings B, J, & G require a seat plate.
GCpi: 0.18 Plate Type(s):
Members not listed have forces less than 375#
Wind Duration: 1.60 WAVE VIEW Ver: 20.02.00A.1020.20
Maximum Top Chord Forces Per Ply (Ibs)
Lumber
Chords Tens.Comp. Chords Tens. Comp.
Top chord: 2x4 SP #2 N; T2,T3 2x6 SP SS;
B - C 1490 -3257 C - D 1241 -2997
Bot chord: 2x4 SP #2 N; B1 2x4 SP #1;
Webs: 2x4 SP #3; W6 2x4 SP #2 N;
Maximum Bot Chord Forces Per Ply (Ibs)
Bracing
Chords Tens.Comp. Chords Tens. Comp.
(a) 1X4 #3SRB or better continuous lateral restraint to
B - N 2856 -1286 L - K 2796 -1324
be equally spaced. Attach with (2) 8d Box or Gun
N - M 2881 -1290 K - J 786 -1809
nails(0.113"x2.5",min.). Restraint material to be supplied
and attached at both ends to a suitable support by
M - L 2796 -1324 J - 1 786 -1809
erection contractor.
(a) or scab reinforcement may be used in lieu of CLR
Maximum Web Forces Per Ply (Ibs)
restraint. substitute (1) scab for (1) CLR and (2) scabs
Webs Tens.Comp. Webs Tens. Comp.
for (2) CLR'S where shown. Scab reinforcement to be
same size, species, grade, and 80% length of web tlili34:SdDiNj�p
C - N 617 -100 E - J 1942 - 3935
D - K 1577 - 3128 E - I 2051 860
member. Attach with 0.128x3" gun nails @ 6" oc.
a j S; j
K- E 2670 -1054 1- F 365 - 477
Loading '�„s■■■■■®va A�
#1 hip 7-0-0
supports jacks with no webs. boos E f s'•r® %,{r
Wind ■ °¢
Wind loads and reactions based on MWFRS.
No. 648
Wind loading based on both gable and hip roof types. a" a
■
WARNING! This truss is not symmetric, but its ■
exterior geometry makes erection error more
probable. It is imperative that this truss be installed $T o
i
properly. k
o
COA #0 1UNAL
03/] 0/2021
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition
Component Safety Information, r
of BCSI (Building
by TPI and SBCA) safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)V attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise.
Refer to
drawings 16OA-Z for standard plate positions. Refer to job's General Notes page for additional information.
ALPINE
Alpine, a division of ITW Buildin Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the ANMCOWAW
truss in conformance with ANSI/�Pl. 1, or for handling, shipping,, installation antl bracin4of trusses. A seal on this drawing or cover pale
listing this drawing indicates acceptance of professional en iineering responsibilitty�r solely -for the design shown. The suitability and use of this 6750 Forum Drive
drawing for any structure is the responsibility of the Building -Designer ANSI/TPI 1 Sec.2. Suite 305
per
For more information see these web sites: Alpine: al ine!tw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.orcl Orlando FL, 32821
SEQN: 496571 SCIS Ply: 1 Job Number: N333978 Cust: R 8975 JRef:1X3L89750074 T13 /
FROM: RWM Qty: 3 7A5/320 ,167EC ,RJ01 / 1672/ARIAI4EAB ELEV.0 DrwNo: 069.21.1302.24999
Truss Label: Bt SSB / OF 03/10/2021
5-1"4
5'1"4
9,8"
4'6"12
=4X4
D
12
6 77- 2C 4
T2
(V �
in
1114X4
E
B T
,V3
�, A 1e,e„
H G FI
1,
12'8"
8
8'
48
12'8"
5'4" -i
54
18,
Loading Criteria (psi) Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦ Maximum Reactions (Ibs)
TCLL: 20.00
Wind Std: ASCE 7-16
Pg: NA Ct: NA CAT: NA
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
TCDL: 7.00
Speed: 160 mph
Pf: NA Ce: NA
VERT(LL): -0.015 C 999 360 Loc R+ / R- / Rh / Rw / U / RL
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(CL): 0.026 C 999 240
B 605 /- /- /357 /330 /200
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.007 F - -
G 466 /- /- /375 /42 /-
Des Ld: 37.00
EXP: C Kzt: NA
HORZ(TL): 0.013 H -
1 350 /- /- /267 /273 !-
NCBCLL: 10.00
Mean Height: 15.00 ft
Building Code:
Creep Factor: 2.0
Wind reactions based on MWFRS
Soffit: 0.00
TCDL: 4.2 psf
BCDL: 5.0 psf
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.758
B Br Width = 8.0 Min Re 1.5
g q =
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
TPI Std: 2014
Max BC CSI: 0.512
G Brg Width = 8.0 Min Req = 1.5
I Brg Width = 8.0 Min Req = 1.5Bearings
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Fac: Yes
Max Web CSI: 0.631
B, G, & I are a rigid surface.
Loc. from endwall: Any
FT/RT:20(0)/10(0)
Bearings B, G, & I require a seat plate.
GCpi: 0.18
Plate Type(s):
Members not listed have forces less than 375#
Wind Duration: 1.60
WAVE
VIEW Ver: 20.02.00A.1020.20
Maximum Top Chord Forces Per Ply (Ibs)
Lumber
Chords Tens.Comp. Chords Tens. Comp.
Top chord: 2x4 SP #2 N; T2 2x4 SP 2400f-2.OE;
B - C 1005 -812 D - E 460 -249
Bot chord: 2x4 SP #2 N;
C - D 831 -582
Webs: 2x4 SP #3;
Wind Maximum Bot Chord Forces Per Ply (Ibs)
Wind loads based on MWFRS with additional C&C Chords Tens.Comp.
member design. B - H 686 - 856
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types. Maximum Web Forces Per Ply (Ibs)
Additional Notes Webs Tens.Comp. Webs Tens. Comp.
Shim all supports to solid bearing. C - H 547 -304 E - F 545 -305
D - G 296 - 427
°
No. 648
T'E OF
S.m Ole
COA #0
03/10/2021
"WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING
**IMPORTANT'* FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r safety practices poor to pertorming these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)Y attached structural sheathing and bottom chord shall have a properly
attache ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10
as applicabgle. Apply plates to each face of truss and position as shown above and on the JoInt9Detalls, unless noted otherwise:' Defer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, adivision-of ITW Buildingq� Components Group Inc. shall not. be responsible for any deviation from this drawing, any, failure to build the ANf COMPANY
truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawm or cover pa a 675o Forum Drive
listing this drawin indicates acceptance of Professional engpeering responsibility solely -for the design shown. The suitability and use of )his Suite Fos
drawing for any sfructure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see these web sites: Alpine: alpineitw com• TPI• tpinst orq• SBCA: sbcindustrycom• ICC• iccsafe orq• AWC• awc orq Orlando FL, 32821
SEQN: 49658 / GABL Piy: 1 Job Number: N333978 Cust: R 8975 JRef:1X3L89750074 T2 /
FROM: RWM Qty: 1 7A5/320 ,167EC .RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.24640
Truss Label: B2GE SSB / DF 03/10/2021
19'4„
9,8„
3,8„
/ =4F4 (TYP)
Loading Criteria (psf) Wind Criteria
TCLL: 20.00 Wind Std: ASCE 7-16
TCDL: 7.00 Speed: 160 mph
BCLL: 0.00 Enclosure: Closed
BCDL: 10.00 Risk Category: II
Des Ld: 37.00, EXP: C Kzt: NA
Mean Height: 15:00 ft
NCBCLL: 10.00 TCDL: 4.2 psf
Soffit: 0.00 BCDL: 5.0 psf
Load Duration: 1.25 MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 " C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3;
Plating Notes
All plates are 2X4 except as noted.
Loading
Gable end supports 8" max rake overhang. Top chord
must not be cut or notched.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See DWGS A16015ENC160118 & GBLLETIN0118 for
gable wind bracing and other requirements.
=07,0
19'4"
19'4"
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
♦ Maximum Reactions (lbs), or*=PLF
Pg: NA Ct: NA CAT: NA
PP Deflection in loc L/defl L/#
Gravity Non -Gravity
Pf: NA Ce: NA
VERT(LL): -0.013 1 999 360
Loc R+ / R- / Rh / Rw / U / RL
B 214 /- /- 1113 /88 1209
Lu: NA Cs: NA
VERT(CL): 0.022 1 999 240
Snow Duration: NA
HORZ(LL): 0.009 1 - -
B* 61 /- /- /45 /17 /-
HORZ(TL): 0.012 1 - -
L 405 /- /- /319 /290 /-
Building Code:
Creep Factor: 2.0
R* 155 /- A /107 /69 A
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
WAVE
Max TC CSI: 0.343
Max BC CSI: 0.258
Max Web CSI: 0.080
M A113
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
B Brg Width = 140 Min Req = -
L Brg Width = 8.0 Min Req = 1.5
R Brg Width = 24.0 Min Req = -
Bearings B, B, L, & J are a rigid surface.
Bearings B, B, L, & J require a seat plate.
VIEW Ver: 20.02.00A.1020.20
Members not listed have forces less than 375#
S Ft 4Z
y
o.
® o
F
I»we.
COA # t
03/10/2021
**WARNING"* READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices nor to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properV1 attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
as appiicabgle. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
truss
listing
Alpine, a division of ITW Buildin Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the ANR CO-AW
in conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracin of trusses; A seal on this drawin or cover pa a 675o Forum Drive
this drawing indicates acceptance of professional enUeering responsibilitty�r solely -for the design shown. The suitabili>9y and use of This
drawing for any structure is the responsibility of the Building Designer ANSVT_P] 1 Sec.2. Suite 305
per
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Odando FL, 32821
SEQN: 49659 / GABL Ply: 1 Job Number: N333978 Cusl: R 8975 JRei:1X3L89750074 T1 /
FROM: RWM Qty: 1 , A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.24593
Truss Label: C1GE SSB / DF 03/10/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Soacina: 24.0 "
T
fo
rn
N
l
47
4-2"
i-- 2' -'
(TYP)
�-- 2'2" 4X4
D
8-4"
4-2"
12 T
6
C E
N
O
B F
A G 8,8„
J H
2X4(A1) = 2X4(A1)
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wnd Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3;
Plating Notes
All plates are 2X4 except as noted.
Loading
Gable end supports 8" max rake overhang. Top chord
must not be cut or notched.
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See DWGS Al6015ENC160118 & GBLLETIN0118 for
gable wind bracing and other requirements.
8'4"
8'4"
8-4"
Snow Criteria (Pg;Pf in PSF)
Pg: NA Ct:-NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.003 1 999 360
VERT(CL): 0.005 1 999 240
HORZ(LL): 0.001 H - -
HORZ(TL): 0.003 H
Creep Factor: 2.0
Max TC CSI: 0.160
Max BC CSI: 0.089
Max Web CSI: 0.092
03/10/2021
Ver: 20.02.00A.1020.20
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
♦Maximum Reactions (lbs), or*=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B* 185 /- /- /135 /87 /59
F* 185 /- /- /135 /87 /-
Wind reactions based on MWFRS
B Brg Width = 24.0 Min Req = -
F Brg Width = 24.0 Min Req = -
Bearings B & H are a rigid surface.
Bearings B & H require a seat plate.
Members not listed have forces less than 375#
Alpine, a division of ITW Building Components Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the
truss in conformance with ANSI O PI 1, or for handling, shipping,. installation and bracin of trusses. A seal on this drawing or cover page
listing this drawing indicates acceptance of professional engineering responsibility solely or the design shown. The suitability and use of This
drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.oru: SBCA: sbcindustrv.com: ICC: iccsafe.orc: AWC: awc.orn
ALPINE
AN M COMPANY
6750 forum Drive
Suite 305
Orlando FL, 32821
SEQN:49660/ VAL Ply: 1 Job Number: N333978 Cust:R8975 JRef:1X3Las750074 T6 /
FROM: RWM Qty: 1 , A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.25250
Truss Label: MV1 SSB / WHK 03/10/2021
Loading Criteria (psi)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
1=12
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Additional Notes
See DWGS VALTN160118 and VAL180160118 for
valley details.
1112X4
B
IL
6
=4X4(D1) N
A
Ll 9'10"14
CD
1113X6
4'3"9
4'3"9
4'3"9
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf., NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
III
COA
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.004 C
HORZ(TL): 0.007 C
Creep Factor: 2.0
Max TC CSI: 0.310
Max BC CSI: 0.224
Max Web CSI: 0.139
03/10/2021
Ve r: 2 0.02.00A.1020.20
♦Maximum Reactions (lbs), or*=PLF
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
D* 75 /- /- /50 /15 /16
Wind reactions based on MWFRS
D Brg Width = 51.6 Min Req = -
Bearing A is a rigid surface.
Members not listed have forces less than 375#
"WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as appllcaboe. App�ji plates to each face oT truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinctComponents Group Inc. shall not.be responsible for any deviation from this drawing, any failure to build the ANMCOWC W
truss in conformance with ANSI 1, or for handling, shipping,, Installation and bracin of trusses. A seal on this drawin or cover pa a 675o Forum Drive
listing this drawing indicates acceptance of professional en Ineering responsibility solely -for the design shown. The suitability and use of g !s
drawing for any structure is the responsibility of the Building -Designer per ANSIITP1 1 Sec.2. Suite 305
For more -information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 49661 / VAL Ply: 1 Job Number: N333978 Cust: R 8975 JRef:1x3L89750074 T7 /
FROM: RWM Qty: 1 7A51320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.24655
Truss Label: MV2 SSB / WHK 03/10/2021
12
6 F7- III2X4B
4X4(D1) T
A
N
�—
Ll 10'10"14
V7;7z7 CD
1112X4
I_ 2'3"9
"J
2'3"9 1
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udefl U#
TCDL: 7.00
Speed: 160 mph
Pf: NA Ce: NA
VERT(LL): NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
VERT(CL): NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
HORZ(LL): 0.000 C
Des Ld: 37.00
EXP: C Kzt: NA
ei
Mean Hei
Height: 15.00 ft
HORZ(TL): 0.001 C -
NCBCLL: 10.00
TCDL: psf
Building Code:
Creep Factor: 2.0
Soffit: 0.00
BCDL: 5.0 psf
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.071
Load Duration: 1.25
MWFRS Parallel Dist: h to 2h
TPI Std: 2014
Max BC CSI: 0.065
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Fac: Yes
Max Web CSI: 0.047
Loc. from endwall: not in 9.00 ft
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s): ,
VIEW Ver: 20.02.00A.1020.20
Wind Duration: 1.60
WAVE
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Webs: 2x4 SP #3;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Right end vertical not exposed to wind pressure.
Wind loading based on both gable and hip roof types.
Additional Notes
See DWGS VALTN160118 and VAL180160118 for
valley details.
03/10/2021
♦ Maximum Reactions (lbs), or •=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
D* 75 /- /- /46 /11 /14
Wind reactions based on MWFRS
D Brg Width = 27.6 Min Req = -
Bearing A is a rigid surface.
Members not listed have forces less than 375#
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing, and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary. -
bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly
attached ri id ceiling Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections 83, B7 or B10,
as applicabgle. Apply plates to each face otruss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinccLLComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the AN-COWMY
truss in conformance with ANSI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engpineering responsibilit�yr solely or the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSVFT l 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 49662 / VAL Ply: 1 Job Number: N333978 Cust: R 8975 JRefAX3L89750074 T5
FROM: RWM Qty: 1 ,7A5/320 ,167EC ,RJ01 / 16721ARIA14EAB ELEV.0 DrwNo: 069.21.1302.24452
Truss Label: VI �SSB / WHK 03/10/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
1'5"13 2'11"9
1'5"13 1'5"13
4X4(D1)
12
6 [�7- - 4X4
B4X4(D1)
T A C
N
13'1"
D
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: 11
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 It
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
See DWGS VALTN160118 and VAL180160118 for
valley details.
i 2' 11 "9
2'11"9 !
E 2'11„9 i
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
M
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.002 999 360
VERT(CL): 0.003 999 240
HORZ(LL): -0.001 - -
HORZ(TL): 0.001 -
Creep Factor: 2.0
Max TC CSI: 0.040
Max BC CSI: 0.058
Max Web CSI: 0.000
Ver: 20.02.00A.1020.20
0
irf1AK01 {i -
03/10/2021
♦Maximum Reactions (lbs), or*=PLF
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
D* 75 /- /- /30 /13 /5
Wind reactions based on MWFRS
D Brg Width = 35.6 Min Req = -
Bearing A is a rigid surface.
Members not listed have forces less than 375#
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r sa ety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached rigid ceilin Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10, _
as applicable. Appy plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE�
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the MN COWAW
truss in conformance with ANSI/ PI 1, - or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional engineering responsibility solely or the design shown. The suitability and use offhis
drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbdndusl .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 49663 / EJAC Ply: 1 Job Number: N333978 Cust: R 8975 JRef:1X3L89750074 T8 /
FROM: RWM Qty: 20 , A5/320 ,167EC ,RJ01 / 16721ARIA14EAB ELEV.0 DrwNo: 069.21.1302.25061
Truss Label: EJ7 SSB / WHK 03/10/2021
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
L
12'2"11
12
6
M
_O LO
Ch M
V'
B
1 A 8-8"
D
1 � 7-
7-
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II_ _
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h/2 to h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 4.50 it
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1;
Bot chord: 2x4 SIP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
03/10/2021
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.015 D
HORZ(TL): 0.028 D
Creep Factor: 2.0
Max TC CSI: 0.720
Max BC CSI: 0.507
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 331 /- /- /249 /108 /208
D 125 /- /- /73 /- !-
C 174 /- /- /128 /169 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary _
bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly
attached ri id ceilin Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3, B7 or B10,
as applicabgle. App�y plates to each face of truss and position as shown above and on the Joint Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not, be res onsible for any deviation from this drawing, any failure to build the ANR CGWV
truss in conformance with ANSI/ PI 1, or for handling, shipping,. installapion and bracin4of trusses. A seal -on this drawn or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional enprneering responsibility solely -for the design shown. The suitabilif'y and use of This
drawing for any structure is the responsibility of the Building -Designer per ANSI/Twl 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 496641 EJAC Ply: 1 Job Number: N333978 Cust: R 8975 JR&AX3L89750074 T4 /
FROM: RWM Qty: 1 , A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.24765
Truss Label: EJ7A SSB / WHK 03/10/2021
I
Loading Criteria (psf)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 10.00
Soffit: 0.00
Load Duration: 1.25
Spacing: 24.0 "
T
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: h to 2h
C&C Dist a: 3.00 ft
Loc. from endwall: not in 9.00 ft
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #1;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131"x3.0", min. toe -nails at bottom chord.
B
7'
7'
Snow Criteria (Pg,Pf in PSF)
Defl/CSI Criteria
Pg: NA Ct: NA CAT: NA
PP Deflection in loc Udefl U#
Pf: NA Ce: NA
VERT(LL): NA
Lu: NA Cs: NA
VERT(CL): NA
Snow Duration: NA
HORZ(LL): 0.016 C
HORZ(TL): 0.030 C
Building Code:
Creep Factor: 2.0
FBC 7th Ed. 2020 Res.
Max TC CSI: 0.738
TPI Std: 2014
Max BC CSI: 0.513
Rep Fac: Yes
Max Web CSI: 0.000
FT/RT:20(0)/10(0)
Plate Type(s):
VIEW Ver: 20,02.00A.1020.20
WAX/P
12'2"11
M
o_
M
8'8"
♦ Maximum Reactions (lbs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
A 270 A /- /179 /33 /136
C 126 /- A /76 /- /-
B 177 /- A /132 /116 /-
Wind reactions based on MWFRS
A Brg Width = 8.0 Min Req = 1.5
C Brg Width = 1.5 Min Req = -
B Brg Width = 1.5 Min Req = -
Bearing A is a rigid surface.
Bearing A requires a seat plate.
Members not listed have forces less than 375#
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI an � SBCA) fo'r safpety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached ripid ceiling Locations shown for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or 1310.
as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinlComponents Group Inc. shall not. be responsible for any deviation from this drawing, any failure to build the A"MCQWAW
truss in conformance with ANSI/l PI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawing or cover page 675o Forum Drive
listing this drawing indicates acceptance of professional engineering responsibilittyy solely or the design shown. The suitability and use of this
drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 49665 / JACK Ply: 1 Job Number: N333978 Cust: R 8975 JRef:1X3L89750074 T21
FROM: RWM Qty: 6 .7A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DnvNo: 069.21.1302.24905
Truss Label: CJ5 KD / YK 03/10/2021
T
4' 11 "4
1' T
4' 11 "4
Loading Criteria (psf)
Wind Criteria
Snow Criteria (Pg,Pf in PSF)
TCLL: 20.00
Wind Std: ASCE 7-16
Pg: NA Ct: NA CAT: NA
TCDL: 7.00
Speed: 160 mph
Pf: NA Ce: NA
BCLL: 0.00
Enclosure: Closed
Lu: NA Cs: NA
BCDL: 10.00
Risk Category: II
Snow Duration: NA
Des Ld: 37.00
EXP: C Kzt: NA
NCBCLL: 10.00
Mean Height: 15.00 ft
Building Code:
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
FBC 7th Ed. 2020 Res.
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
TPI Std: 2014
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Rep Fac: Yes
Loc. from endwall: not in 4.50 it
FT/RT:20(0)/10(0)
GCpi: 0.18
Plate Type(s):
Wind Duration: 1.60
1——
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131"x3.0", min. toe -nails at bottom chord.
C
Defl/CSI Criteria
PP Deflection in loc L/defl LJ#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): 0.005 D
HORZ(TL): 0.010 D -
Creep Factor: 2.0
Max TC CSI: 0.549
Max BC CSI: 0.257
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
' s
s%°
I
0
v STATE OF c�
g®0Ri-.
COA # l
03/10/2021
11'2"5
co
r—
CM
8'8"
♦ Maximum Reactions (lbs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 256 /- /- 1200 /88 /152
D 89 /- /- /51 /- /-
C 118 /- /- /85 M I S /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlingshipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attached ri id ceilin Locations shown for Permanent lateral restraint of webs shall have bracinq installed per BCSI sections B3, B7 or B10,
as applicab)e. Applgy plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not, be responsible for any deviation from this drawing, any failure to build the
truss in conformance with ANSI/ PI 1, or for handling, shipping,, installation and bracin of trusses. A seal on this drawin or cover pa e
listing this drawing indicates acceptance of professional enUeering responsibilit solely -for the design shown. The suitabiliply and use of 4 is
drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2.
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ]CC: iccsafe.or ; AWC: awc.or
ALPINE
AN" COMPAW
6750 Forum Drive
Suite 305
Orlando FL, 32821
SEQN: 49666 / JACK Ply: 1 Job Number: N333978 Cust: R 8975 JRef:1X3L89750074 T20 /
FROM: RDP Qty: 6 7A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.24858
Truss Label: CJ3 SSB / WHK f 03/10/2021
Loading Criteria (psf)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
Des Ld: 37.00
EXP: C Kzt: NA
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131"x3.0", min. toe -nails at bottom chord.
2' 11 "4
2' 11 "4
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA
CAT: NA
Pf: NA
Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
C
c'M
Defl/CSI Criteria
PP Deflection in I= Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.001 D -
HORZ(TL): 0.001 D
Creep Factor: 2.0
Max TC CSI: 0.234
Max BC CSI: 0.105
Max Web CSI: 0.000
EW Ver: 20.02.00A.1020.20
► V� o®atanoadky4
10'2"5
0)
M
N
8'8"
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ /R- /Rh /Rw /U /RL
B 185 /- /- /156 /71 /99
D 50 /- /- /27 /- /-
C 63 /- /- /44 /64 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
"WARNING" READ AND FOLLOW ALL NOTES ON THIS DRAWING!
"'IMPORTANT" FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin shipping, installing and bracing. Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r safety practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have proper)v attached structural sheathing and bottom chord shall have a properly
attached rigid ceiling Locations shown -for ermanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10, _
as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE�
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinQQComponents Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the A-COMDAW
truss in conformance with ANSI/TPI 1, or for handling, shipping,, installation and bracingq� of trusses. _A seal on this drawing or cover page — 6750 Forum Drive
listing this drawing indicates acceptance of professional en sneering responsibility solely for the design shown. The su!tabil!Cy and use of this
drawing for any structure is the responsibility of the Buildinguesigner per ANSIITPI 1 Sec.2. Suite 305
For more information see these web sites: Alpine: ai ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.org Orlando FL, 32821
SEQN: 496671 JACK Ply: 1 Job Number: N333978 Cust: R 8975 JRef:1X3L89750074 T9 !
FROM: RDP Qty: 6 , A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.24718
Truss Label: CA SSB / WHK 03/10/2021
12
6 [7- C
B M
43
A �-
D
2X4(A1)
1 I e 11114 �ji
A A II
Loading Criteria (psi)
Wind Criteria
TCLL: 20.00
Wind Std: ASCE 7-16
TCDL: 7.00
Speed: 160 mph
BCLL: 0.00
Enclosure: Closed
BCDL: 10.00
Risk Category: II
EXP: C Kzt: NA
Des Ld: 37.00
Mean Height: 15.00 ft
NCBCLL: 10.00
TCDL: 4.2 psf
Soffit: 0.00
BCDL: 5.0 psf
Load Duration: 1.25
MWFRS Parallel Dist: 0 to h/2
Spacing: 24.0 "
C&C Dist a: 3.00 ft
Loc. from endwall: Any
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Bot chord: 2x4 SP #2 N;
Wind
Wind loads based on MWFRS with additional C&C
member design.
Wind loading based on both gable and hip roof types.
Additional Notes
Provide (2) 0.131 "x3.0", min. toe -nails at top chord.
Provide (2) 0.131 "x3.0", min. toe -nails at bottom chord.
I�
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA CAT: NA
Pf: NA Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: Yes
FT/RT:20(0)/10(0)
Plate Type(s):
03/10/2021
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): NA
VERT(CL): NA
HORZ(LL): -0.000 D
HORZ(TL): 0.000 D -
Creep Factor: 2.0
Max TC CSI: 0.183
Max BC CSI: 0.022
Max Web CSI: 0.000
VIEW Ver: 20.02.00A.1020.20
912115
•
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 143 /- /- /145 /76 ME
D 11 /-2 /- /14 /10 /-
C - /-15 /- /29 /33 /-
Wind reactions based on MWFRS
B Brg Width = 8.0 Min Req = 1.5
D Brg Width = 1.5 Min Req = -
C Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
**WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING!
—IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating handlin shipping, installing and bracing. , Refer to and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) for safety practices prior to performing these functions. Installers shall provide temporary
bracing perBCSI. Unless noted otherwise, top chord shall have properly attached structural sheathing and bottom chord shall have a properly
attachetl rigid cei!inp Locations shown for permanent lateral restraint of webs shall have bracin installed per BCSI sections B3, B7 or B10,
as applicable. Apply plates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Refer to ALPINE
drawings 16DA-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW Buildin Components Group Inc. shall not, be responsible for any deviation from this drawing, any, failure to build the ANR COMPANY
truss in conformance with ANSIf� PI 1, or for handling, shipping,, Installation and bracin4 of trusses. A seal on this drawing or cover pa a 675o Forum Drive
listing this drawing indicates acceptance of professional en ineering responsibility solely -for the design shown. The suitabilifY and use of this
drawing for any structure is the responsibility of the Building -Designer per ANSI/T�I 1 Sec.2. Suite 305
For more information see these web sites: Alpine: al ineitw.com; TPI: t inst.or ; SBCA: sbcindust .com; ICC: iccsafe.or ; AWC: awc.or Orlando FL, 32821
SEQN: 49668 / HIP_ Ply: 1 Job Number: N333978 Cust: R 8975 JRef:1X3L89750074 T19 /
FROM: HMT Qty: 3 7A5/320 ,167EC ,RJ01 / 1672/ARIA/4EAB ELEV.0 DrwNo: 069.21.1302.21734
Truss Label: HJ7 KD / WHK 03/10/2021
T
4'3
Loading Criteria (psi)
TCLL: 20.00
TCDL: 7.00
BCLL: 0.00
BCDL: 10.00
Des Ld: 37.00
NCBCLL: 0.00
Soffit: 0.00
Load Duration: 1.25
SPacina: 24.0 "
5'3"5
5'3"5
9'10"1
4'6"11
0
127'3
12
4.24 2X4
C
_c
M
-v
B
q 8'8"
FE
2X4(A11 =4X4
1'5"
Wind Criteria
Wind Std: ASCE 7-16
Speed: 160 mph
Enclosure: Closed
Risk Category: II
EXP: C Kzt: NA
Mean Height: 15.00 ft
TCDL: 4.2 psf
BCDL: 5.0 psf
MWFRS Parallel Dist: 0 to h/2
C&C Dist a: 3.00 ft
Loc. from endwall: NA
GCpi: 0.18
Wind Duration: 1.60
Lumber
Top chord: 2x4 SP #2 N;
Sot chord: 2x4 SP 2400f-2.0E;
Webs: 2x4 SP #3;
Loading
Hipjack supports 6-11-8 setback jacks with no webs.
Wind
Wind loads and reactions based on MWFRS.
Wind loading based on both gable and hip roof types.
(3) 16d common (0.162"x3.5") nails at top chord
(3) 16d common (0.162"x3.5") nails at bottom chord
9'2"2
9'2"2
Snow Criteria (Pg,Pf in PSF)
Pg: NA Ct: NA
CAT: NA
Pf: NA
Ce: NA
Lu: NA Cs: NA
Snow Duration: NA
Building Code:
FBC 7th Ed. 2020 Res.
TPI Std: 2014
Rep Fac: No
FT/RT:20(0)/10(0)
Plate Type(s):
03/10/2021
' 9'1
Defl/CSI Criteria
PP Deflection in loc Udefl U#
VERT(LL): 0.040 F 999 360
VERT(CL): 0.076 F 999 240
HORZ(LL): 0.010 C - -
HORZ(TL): 0.018 C
Creep Factor: 2.0
Max TC CSI: 0.546
Max BC CSI: 0.416
Max Web CSI: 0.260
VIEW Ver: 20.02.00A.1020.20
♦ Maximum Reactions (Ibs)
Gravity Non -Gravity
Loc R+ / R- / Rh / Rw / U / RL
B 326 /- A /- /154 /-
E 364 /- /0 /- /84 /0
D 214 /- /- /- /177 /-
Wind reactions based on MWFRS
B Brg Width = 10.6 Min Req = 1.5
E Brg Width = 1.5 Min Req = -
D Brg Width = 1.5 Min Req = -
Bearing B is a rigid surface.
Bearing B requires a seat plate.
Members not listed have forces less than 375#
Maximum Top Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B - C 394 - 562
Maximum Bot Chord Forces Per Ply (Ibs)
Chords Tens.Comp.
B - F 531 - 358
Maximum Web Forces Per Ply (Ibs)
Webs Tens.Comp.
C - F 394 - 583
**WARNING— READ AND FOLLOW ALL NOTES ON THIS DRAWING!
**IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS
Trusses require extreme care in fabricating, handlin shipping, installing and bracing. Refer to. and follow the latest edition of BCSI (Building
Component Safety Information, by TPI and SBCA) fo'r saty practices prior to performing these functions. Installers shall provide temporary
bracing per BCSI. Unless noted otherwise, top chord shall have properir attached structural. sheathing and bottom chord shall have a properly
attached rigid ceiling Locations shown for Permanent lateral restraint of webs shall have bracinc] installed -per BCSI sections B3, B7 or B10,
as applicable. Apply Oates to each face of truss and position as shown above and on the Join Details, unless noted otherwise. Ifefer to ALPINE
drawings 160A-Z for standard plate positions. Refer to job's General Notes page for additional information.
Alpine, a division of ITW BuildinTComponents Group Inc. shall not be responsible for any deviation from this drawing, any failure to build the ANMCO-V
truss in conformance with ANSI 4PI 1, or for handling, shipping,, installation and bracingp of trusses. A seal on this drawing or cover pa a 6750 Forum Drive
listing this drawing indicates acceptance of professional en ineenng responsibili((yy solely for the design shown. The suitabiliCy and use of This
drawing for any structure is the responsibility of the Building -Designer per ANSVTT l 1 Sec.2. Suite 305
For more information see these web sites: Alpine: alpineitw.com; TPI: tpinst.ora: SBCA: sbcindustry.com: ICC: iccsafe.ora: AWC: awc.oro Orlando FL, 32821
Gable Stud Reinforcement Detail -
ASCE 7-161 160 mph Wind Speed, 15' Mean Height, Enclosed, Exposure C, Kzt = 1.00
• Uri 140 Mph Wind Speed, 15' Mean Height, Partially Enclosed, Exposure C, Kzt = 1.00
Uri 140 mph Wind Speed, 15' Mean Height, Enclosed, Exposure D, Kzt = 1.00
❑ri t?0 mnh Wind SnPod iS' Me..., uel„l,+ o....+i..u., r-i-, r.- ._
2x4 Brace
Gable Vertical
Spacing Species Grade
No
Braces
(1) lx4 'L' Brace A
(1) 2x4 'L' Brace w
(2) 2x4 'L' Brace ww
(1) 2x6 'L'rBrace w
(2) 2x6 'L' Brace R
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
Group A
Group B
S
#1 #2
0)
U
I r
#3
3' 8'
5' 9'
6' 2'
7' 8'
7' illRc�)'
9' 6'
12' 0'
12' 6'
14' 0'
14' 0'
Stud
3' 8'
5' 9'
6' 1'
7' 8'
7' 11'
9' 6'
12' 0'
12' _
14' 0'
14' 0'
Q
Standard
3' 8'
4' 11'
5' 3'
6' 7'
7' 1'
ill
9' 6'
10' 4'
11' 1'
14' 0'
14' 0'
#1
4' 0'
6' 8'
6' 11'
7' 10'
8' 2'
9'8'12'
4'
12' 9'
14' 0'
14' 0'
S P
#2
3' 10,
6' 7'
6' 10,
7' 9'
8'1'9'
7'
12' 2'
12' 8'
14' 0'
14' 0'
#33'
9'
5' 3'
5' 7'
6' 11'
7' 5'
92
9' 7'
10' 11'
11' 8'
14' 0'
14' 0'
Dr
Stud
3' 9'
5' 3'
5' 7'
6' 11'
7' 5'
9' 2'
9' 7'
10, 11'
11' 8'
14' 0'
14' 0'
U
Standard
3' 6'
4' 7'
4' 11'
6' 2'
6' 7'
8' 4'.
8' 11'
9' 8'
10' 4'
13' 1'
14' 0'
_
[-
S P
#1 / #2
4' 5'
7' 6'
7' 9'
8' 10,
9' 3'
10' 7'
ill 0'
13, ill
14' 0'
14' 0'
14' 0'
_
r
#3
4' 2'
7' 1'
7' 9'
8' 9'
9' 1'
10' 5'
10110,
13' 9'
14' 0';
14' 0'
14' 0'
U
I i P
Stud
4' 2'
7' 1'
7' 6'
8' 9'
9' 1'
10' 5'
10, 10,
13' 9'
14' 0';
14' 0'
14' 0'
QJ
O
HI
Standard
4' 2'
6' 1'
6' 5'
B' 1'
8' 8'
10' 5'
10, 10,
12, 8'
13' 71!
14' 0'
14' 0'
\
#1
4' 7'
7' 7'
7' 11'
9' 0'
9' 4'
10, 8'
11' 1'
14' 0'
14' 0'
14' 0'
14' 0'
/
S P
#2
4' 5'
7' 6'
7' 9'
8' 10,
9' 3'
10' 7'
11' 0'
13' 11'
14' 0'
14' 0'
14' 0'
#3
4' 4'
6' 5'
6' 10,
8' 6'
9' 1'
10, 6'
10' 11'
13' 4'
14' 0'
14' 0'
14' 0'
QJ
D P L
Stud
4' 4'
6' S'
6' 10'
8' 6'
9' 1'
10' 6'
10' 11'
13' 4'
14' 0'
14' 0'
14' 0'
Standard
4' 2'
5' 8'
6' 0'
7' 6'
8' 0'
10, 2'
10, 10,
11' 10,
12' 7'
14' 0'
14' 0'
S
#1 / #2
4' 10'
8' 3'
8' 7'
9' 9'
10, 2'
10' 7'
12, 1'
14' 0'
14' 0'
14' 0'
14' 0'
d I
P P
#3
4' 7'
8' 2'
8' 5'
9' 8'1
10, 0'
11' 6'
12, 0'
14' 0'
14' 0'
14' 0'
14' 0'
LD
U
I_I [
Stud
4' 7'
8' 2'
8' 5'
9' 8'
10, 0'
11' 6'
12' 0'
14' 0'
14' 0'
14' 0'
14' 0'
O
f l l
Standard
4' 7'
7' 0'
7' 5'
9' 4'
10, 0'
11' 6'
12' 0
14' 0'
14' 0'
14' 0'
14' 0'
X
#1
5' 1'
8' 5' 1
8' 8'
9' 11'
10' 3'
11' 9'
12' 3'
14' 0'
14' 0'
14' 0'
14' 0'
d
S P
#2
4' 10'
8' 3'
8' 7'
9' 9'
10' 2'
11' 7'
12' 1'
14' 0'
0'
14' 0'
14' 0'
#3
4' 9'
7' 4'
7' 10'
9' 8'
10, 1'
11' 7'
12' 0'
14' 0'
j4'
4' 0'
14' 0'
14' 0'
�
D F- L
Stud
4' 9'
7' 4'
7' 10'
9' 8'
10' 1'
11' 7'
12' 0'
14' 0'
4' 0'
14' 0'
14' 0'
Standard
4' 7'
6' 6'
6' 11'
8' B'
9' 3'
11' 6'
12' 0'
13' 7'
14' 0'
14' 0'
14' 0'
Diagonal brace options
vertical length may be
doubled when diagonal
brace Is used. Connect
diagonal brace for 600#
at each end, Max web
total length.is 141.
Vertical length shown
In table, above.
Connect diagonal at
midpoint of vertical
AN ITW COI
115141 Earthl City1 Expressway
11 Suite%242
11 Earth% City,1 M0163045
About
18'
L
'L' Brace End
Zones, typ.
2x6 DF-L #2 or
better diagonal r
bracer single 8,
or double cut
(as shown) at
upper end.
Refer to chart k
"VARNIM " READ AND FOLLOW ALL NOTES ON THIS DRAVDi(3
w IWMTANTww FURNISH THIS DRAVING TO ALL CRITRACTMS INCLUDING THE INSTALLER
Trusses require extreme care In fabricating, handling, shipping, InstalUng and bracing. Ref
At.. the latest edition of BCSI (BuRding Component Safety Information, by TPI and SBCA) f n
•actices prior to performing these functions. Installers shall provide temporary bracing p B
-less noted otherwise, top chord shall have properly attached structural sheathing and bo of
all have a properly attached rigid ceiling. Locations shown for permanent lateral restrain f
all have bracing Installed per SCSI sections B3, B7 or B10, as applicable. Apply plates to ea
truss and position as shown above and on the Joint Details, unless noted otherwise.
rfer to drawings 160A-Z for standard plate positions.
Alpine, a division of ITV Building Components Group Inc shall not be responsible for any deviatl.
is drawing, any fallure to build the truss In conformance with ANSI/TPI 1, or for handling, shlpl
•tallation 4 bracing of trusses.
A seal on this drawing or cover page listing this drawnng, Mcates acceptance of professional
glneering responsibility solely for the design shown The suitability and use of this drawling
r my structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.P.
For more Information see this Job's general notes Dane and these web sites,
Bracing Group Species and Grades,
Group At
S ruce-Pine-Fir Hen -Fir
#1 / #2 Standard #2 Stud
#3 Stud1 1 #3 Standard
Dou las Flr-Larch Southern Plnewww
#3 #3
Stud Stud
Standard 1 Standard
Group BI
Hem -Fir
#1 & Btr
#1
Dou Ins Fir -Larch Southern Plnewww
#I #1
#2 #2
1x4 Braces shall be SR' (Stress -Rated Board).
wwFor Ix4 So. Pine use only Industrial 55 or
Industrial 45 Stress -Rated Boards. Group B
values may be used with these grades.
Liable I russ lletaiL Notesi
Wind Load deflection criterion Is L/240,
Provide uplift connections for 75 plf over
continuous bearing (5 psf TC Dead Load).
Gable end supports load from 4' 0' outlookers
with 2' 0' overhang, or 12' plywood overhang.
Attach 'L' braces with 10d (0.128'x3.0' min) nalls.
)K For (1) 'L' brace- space nails at 2' o.c.
In 18' end zones and 4' o,c. between zones.
)1()KFor (2) 'L' braces- space nails at 3' o.c.
In IS' end zones and 6' o.c. between zones.
'L' bracing must be a minimum of 80% of web
member length.
Gable Vertical Plate Sizes
Vertical Len th No Slice
Less than 4' 0' 2X3
Greater than 4' 01, but 3X4
Less than 11' 6'
9 Greater than Ill 6' 4X4
• ua .,. dot• Jr ra 1�f + Refer to common truss design for
d ;;� peak, splice, and heel plates,
rim a
p Refer to the Building Designer for conditions
tical#• leng not addressed by this detail.
REF ASCE7-16-GAB16015
DATE 01/26/2018
~jyATE OF d'� DRWG A16015ENC160118
lam_ %�O_bb�
MAX, TOT. LD, 60 PSF
SPACING 24,0'
'T'
Reinforcing
Member
Gable
Truss
Gabe Detail
For Let -in Verticals
Gable Truss Plate Sizes
ppropriate Alpine gable detail for
e sizes for vertical studs.
Engineered truss design for peak,
gib, and heel plates,
vertical plates overtop, use a
.te that covers the total area of
lapped plates to span the web,
ei 2*2X4
2X8
Provide connections for uplift specified on the engineered truss design
Attach each 'T' reinforcing member with
End Driven Nnilsi
10d Common (0,148'x 3,',min) Nalls at 4' o,c, plus
(4) nails In the top and bottom chords.
Toenalled Nallsi
10d Common (0.148'x3',min) Toenails at 4' o,c. plus
(4) toenails In the top and bottom chords.
This detail to be used with the appropriate Alpine gable detail for ASCE
wind load.
ASCE 7-05 Gable Detall Drawings
A13015051014, A12015051014, A11015051014, A10015051014, A14015051014,
A13030051014, A12030051014, A11030051014, A10030051014, A14030051014
ASCE 7-10 & ASCE 7-16 Gable Detail Drawings
A11515ENC100118, A12015ENC100118, A14015ENC100118, A16015ENC100118,
A18015ENC100118, A20015ENC100118, A20015END100118, A20015PED100118,
A11530ENC100118, A12030ENC100118, A14030ENC100118, A16030ENC100118,
A18030ENC100118, A20030ENC100118, A20030END100118, A200 D100118,
S11515ENC100118, S12015ENC100118, S14015ENC100118
S18015ENC100118, S20015ENC100118, S20015END1 E 41*
S11530ENC100118, S12030ENC100118, S140131 11518030ENC100118, S20030ENC100118, S20ft,.,��pp1� 1;See appropriate Alpine gable detail for mn>dced oub ON
'T' Reinforcement Attachment Detail
'T' Reinforcing 'T' Reinforcing
Member Member
Toe-nall - Or - End -pall
To convert from 'L' to 'T' reinforcing members,
multiply 'T' Increase by length (based on
appropriate Alpine gable detail).
Maximum allowable 'T' reinforced gable vertical
length Is 14' from top to bottom chord,
'T' reinforcing member material must match size,
specie, and grade of the 'L' reinforcing member.
eb Length Increase w/ °T' Brace
Examples
ASCE 7-10 Wind Speed = 120 mph
Mean Roof Height = 30 ft, Kzt = 1.00
Gable Vertical = 24'o.c, SP #3
'T' Reinforcing Member Size = 2x4
'T' Brace Increase (From Above) = 30% = 1.30
(1) 2x4 'L' Brace Length = 8' 7'
Maximum 'T' Reinforced Gable Vertical Length
1.30 x 8' 7' = 11' 2'
'T' Relnf.
Mbr, Size
'T'
Increase
2x4
30
2x6
20
vVAI$IINCdo W-0 AND FI71OV ALL MMS a THIS DRAVBi(d �° _ ' REF LET -IN VERT
WIMP RTANT" rURIIISH THIS BRAVING TO ALL CONTRACTORS BICLUDING TFE INSTALLER �p,,. e •
Trusses require extreme care N fabricating, handling, shipping, InstalUrl and hrncing. Ref biro e DATE Ol/02/2018
follow the latest edition of BCSI (Building Component Safety Information, by TP! and SBCA) f a
practices prior to performing these functions. Installers shall provide temporary bracing p CSL s 0 Unless noted otherwise, top chord shall have property attached structural sheathing and bo 0 040
ATE I�� DRWG GBLLETIN0118
shall have a properly attached rigid calling. Locations shown for permanent lateral restroln q�
shall have bracing Installed per BCSI sections B3, B7 or BID, as applicable. Apply plates to en
of truss and position as shorn above and on the Joint DetaDs, unless noted otherwise. - 4���M
IAILPI
ReFer to drawings 16DA-Z for standard plate positions. q
Alpine, n division of ITV Building Components Group Inc shall not be responsible for any devlatl or grq,�geNytA
ANrrWCOMPANY Installationge, bracing of trusses. a truss N conformance with ANSI/TPI 1, or for handling, shlppin ` MAX, TOT, LD, 60 PSF
A seal on this drawing or cover page Usting this drawing, Indicates acceptance of professional
\\514\Earth\City\Expressway engineering responsBiflity solely for the design shown The suit Wty and use of this drawing DUR, FAC, ANY
\\Suite\242 far any structve hi the responsibility of the Balding Designer per ANSI/TPI 1 See2.
\\Earth\City,\MO\63045 For more Information see this Job's general notes page and these web sites MAX, SPACING 24,0'
ALPINE, www.alpineltw.comi TPD www.tpinst.orgi SBCAi www.sbcindustry.orgi ICd vdccsnfe.org
Valley Detail - ASCE 7-161 180 mph, 30' Mean Height, Partially Enclosed, Exp, C, Kzt=1,00
Top Chord 2x4 SP 42N, SPF #1/#2, DF-L #2 or better,
Dot Chord 2x4 SP #2N or SPF #1/#2 or better,
Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better,
3"� Attach each valley to every supporting truss with,
535# connection or with (1) Simpson H2,5A or
equivalent connector for
ASCE 7-16 180 mph, 30' Mean Height, Part, Enc,
Building, Exp, C, Wind TC DL=5 psf, Kzt = 1.00
Or
ASCE 7-16 160 mph, 30' Mean Height, Part, Enc,
Building, Exp, D, Wind TC DL=5 psf, Kzt = 1.00
Bottom chord may be square or pitched cut
as shown.
Valleys short enough to be cut as solid triangular
members from a single 2x6, or larger as required,
shall be permitted in lieu of fabricating from
separate 2x4 members,
All plates shown are Alpine Wave Plates,
3X4
����M
12 Max,
2X4
!W 8-0-0 max NJ
4X4
Unless specified otherwise on
engineer's sealed design, for vertical
valley webs taller
than 7-9'
apply 2x4 'T'
reinforcement, 80% length of
web, same species
and grade
or better, attached with 10d box
(0,128' x 3,0') nails
at 6' o,c,
In lieu of 'T'
reinforcement, 2x4 Continuous
Lateral Restraint
applied at
mid -length of
web is permitted with diagonal
bracing as shown In
DRWG BRCLBANC1014,
Top chord of truss beneath valley set must be braced with,
properly attached, rated sheathing applied prior to valley truss
Installation,
Or
Purlins at 24' o,c, or as otherwise specified on engineer's sealed design
Or
By valley trusses used in lieu of purlin spacing.as specified on
Engineer's sealed design,
www Note that the purlin spacing for bracing the top chord of the truss
beneath the valley is measured along the slope of the top chord,
++ Larger spans may be built as long as the vertical height does
not exceed 14'-0',
Pitched Cut
Bottom Chord
Valley
20-0-0 (++) Wj
Supporting trusses at 24' o,c, maximum spacing,
2X4
Valle
Spacing
Square Cut Stubbed Valley
Bottom Chord End Detail
Valley
"VARNDG— READ AND FoLLOV ALL MITES [IN THIS DRAVDIGI t
.wIN MTANTaw FLALNISH T= DRAVING TO ALL CONTRACTORS ucLUDUIG THE INSTALLER&
Trusses require extreme care In fabricating, handling, shipping, Installing and bracing. Refer
follow the latest edition of SCSI CBuRding Component Safety Information, by TPI and SBCA) for fgj,
&PNEpractices prior to performing these functions. Installers shall provide temporary bracing per �L
Unless noted otherwise, top chord shall have properly attached structural sheathing and bo ��jj
thls
shall have a properly attached rigid ceiling. Locations shorn for permanent lateral restraint Ashall have bradng Installed per BCSI sections B3, B7 or BIO, as applicable. Apply plates to each !of truss and position as shorn above and an the Joint Details, unless noted otherwise.
Refer to drawings 160A-Z for standard plate positions,
Alpine,adivision of ITV Building Components Group Inc shall not be responsible for any deviation drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handUng, shipping,
AN ITW COMPANY Installation lL bracing of trusses.
115141 Earth, Ci \ Expressway e A seat on this drawing or cover page Ilsti ng His drahg, Indicates acceptance of professlonal
b P Y or Mn ring structure
i p the
respolely liy of tide BuRtltrg Design=shown.MpeerYANSI� e I Sect. of this �w�
\ 1 Suite\ 242 For any gr responsibility
spon bi the re
\ \ Earth\ City,\ MO\ 63045 For more Information see this Job's general notes page and these web sitesr
ALPINE, wwwalpineltw.conr TPD wn.tpinst.orgi SBCA, www.sbclndustryargl ILO wwwJccsnfearg
Wulf
UE OF � !
4
'PJ�}Lgg�OppPS�
4X4
❑Ptionat Hip
TJoint Detail
t 24'ulo
n Tr
usses
Partial
Framing
2
'
o,c,
Plan
C
LL
30
30 40PSF REF
VALLEY DETAIL
C
DL
20
15 7 PSF DATE
01/26/2018
C
DL
10
10 10 PSF DRWG
VAL180160118
IBC
LL
0
0 0 PSF
TOT. LD, 60 155157PSF
DUR,FAC,1.25/1,3311.1511.15 1
24,0'
Valley Detail - ASCE 7-16: 30' Mean Height, Enclosed, Exp, C, Kzt=1,00
Top Chord 2x4 Sr #2N, SPF #1/#2, DF-L #2 or better,
Bot Chord 2x4 SP #2N or SPF #1/#2 or better.
Webs 2x4 SP #3, SPF #1/#2, DF-L #2 or better,
�� Attach each valley to every supporting truss with:
(2) 16d box (0,135' x 3,5') nails toe -nailed for
ASCE 7-16, 30' Mean Height, Enclosed Building, Exp, C,
Wind TC DL=5 psf, Kzt = 1.00, Max, Wind Speed based on
supporting truss material at connection location:
170 mph for SP (G = 0.55, min;),
155 mph for DF-L (G = 0,50, min,), or
120 mph for HF & SPF (G = 0.42, min,),
Maximum top chord pitch is 10/12 for supporting trusses
below valley trusses,
Bottom chord of valley trusses may be square or
pitched cut as shown.
Valleys short enough to be cut as solid triangular
members from a single 2x6, or larger as required,
shall be permitted in lieu of fabricating from
separate 2x4 members,
All plates shown are Alpine Wave Plates,
3X4
12
12 Max, I
2X4 X4
8-0-0 max
4X4
20-0-0 (++)
Supporting trusses at 24' o,c, maximum spacing,
Unless specified otherwise on
engineer's sealed design, for vertical
valley webs taller
than 7-9'
apply 2x4 'T'
reinforcement, 80% length of
web, same species
and grade
or better, attached with 10d box
(0,128' x 3,0') nails
at 6' o,c,
In lieu of 'T'
reinforcement, 2x4 Continuous
Lateral Restraint
applied at
mid -length of
web is permitted with diagonal
bracing as shown in
DRWG BRCLBANC1014.
Top chord of truss beneath valley set must be braced with:
properly attached, rated sheathing applied prior to valley truss
installation,
Or
Purlins at 24' o,c, or as otherwise specified on engineer's sealed design
Or
By valley trusses used in lieu of purtin spacing as specified on
Engineer's sealed design,
www Note that the purlin spacing for bracing the top chord of the truss
beneath the valley is measured along the slope of the top chord,
++ Larger spans may be built as long as the vertical height does
not exceed 14'-0',
Pitched Cut
Bottom Chord
Valley
2X4
Valle
Spacing
a 11
Square Cut Stubbed Valley
Bottom Chord End Detail
oe-nailed Valley
12
10 Max, 1
A'
"VARNINGIM READ AND FOUMV ALL NIMS ON THIS 1NWWM
WIPORTANTww FURNISH THIS DRAWING TD ALL CMTRACTGRS DICLUDDIG THE INST
Trusses require extreme care In fabricating, handling, shipping, Installing and bracing, Re
fallow the latest edition of BCSI (Building Component Safety Information, by TPI wnd SBCA)
practices prior to performing these functions. Installers shall provide temporar bradng r B
Unless noted otherwise, top chord shall have properly attached structural sheathing and
shall have a properly attached rigid ceiling. Locations shown for permanent lateral rests o
,n shall have bracing Installed per BCSI sections B3, B7 or B10, as applicable. Apply plates to e
I �I of truss and position as shown above and an the Joint Details, unless noted otherwise.
E Refer to drawings 16OA-Z for standard plate positions.
Alpine, a division of ITV Building Components Group Inc. shall not be responsible for any devlat
this drawing, any failure to build the truss In conformance with ANSI/TPI 1, or for handling, ship:
AN ITW COMPANY Installation B bracing of trusses. A seal on this drawing or cover page llstkV this drawing, Indicates acceptance of professional
11514% Earth\ City\ Expressway engineering responsPopity solely for the design shown The suitability and use of this drawing
1\Suite\242 for any structure Is the responsibility of the Mclig Designer per ANSI/TPI 1 Sec2.
\\ Earth\ Cily,1 MO\63045 -- For more Information_ see this Job's general notes page and these web sltesi
4X4
I —
Optional Hip
Joint Detail
24'
w+...... V& -
,, ENPartial
A mon Ti
usses
Framing
�-16at 24'
o,c,
L Plan
a
TC LL 30
30
40PSF
REF
VALLEY DETAI
TIC DL 20
15
7 PSF
DATE
01/26/2018
O+C'
BC DL 10
10
10 PSF
DRWG
VALTN160118
' se
BC LL 0
0
0 PSF
94
1 L
TOT, LD, 60
5557PSF
DUR.FAC.1,25/1.33
1.15
115
SPACING 24,0'
y
VALLEY FRAMING & BRACING DETAIL
ad
Lumber Size and Grade Minumum Requirements
GENERAL NOTES
Purlins required T-O" O.C. in absence of plywood sheathing.
Trusses without sheathing applied must be evaluated accordingly.
Purlins should overlap sheathing one truss spacing minimum.
In cases that this is impractical, overlap sheathing a minimum
of 6", and nail upwards through sheathing into purlin with a
minimum of 8-8d (0.131"x2.5") common wire nails.
Effects of not providing sheathing below a valley set
must be evaluated by the building designer.
This drawing applies to valleys with the following conditions:
Spans (distance between heels) 40'-0" or less
-Maximum valley height: 14'-0"
-Maximum mean roof height: 30 feet
-ASCE 7-05,140 mph, Enclosed, Cat II, Exp B,1=1.0, Kzt=1.0
-Or A Maximum of ASCE 7-10, 180 mph, Enclosed, Exp D, Kzt=1.0
TRUSS
TRUSS UNDER VALLEY FRAMING
VALLEY RAFTER OR RIDGE
® +CRIPPLE
ripples 4'-0" for 30 psf (TL) and 20 psf (TD) Max.
ce the crippes for each row starting from the valleys or sleepers
working Inward to the ridge board so that cripple locations are
gered between rows.
(Typ)
innection Requirement Notes
2x6 rafters to ridge
416d toe -nails
Cripple to ridge
416d toe -nails
Cripple to rafter
416d toe -nails
(••) 816d face -nails
Rafter to sleeper or blocking
516d toe -nails
Rafter to two 2x6 sleepers
416d toe -nails
Sleeper to truss
416d toe -nails
Two 2x6 sleepers to truss
3 16d toe -nails each sleeper 8, truss
Ridge board to roof block
416d toe -nails
Ridge board to truss
416d toe -nails
Purlin to (Typ)
3 16d toe -nails
Truss to blocking
416d toe -nails
Truss to cripple
416d toe -nails
Truss to cripple
416d toe -nails
Cri We to urlin
316d toe -nails
PP
lRv rtC4VIRCV Ir OLCCYCKS AKC UStUI 13. Collar beam to rafter 416d toe -nails
CRIPPLE, BRACING, & BLOCKING NOTES NOTE: 16d (0.162"x3.5") COMMON NAILS
-2x4 continuous lateral restraint (CLR) min. is required for cripples V-0" to 10'-0" long
nailed w/ 2 -10d (0.148"x3") nails. Or 2x4 "T' or scab reinforcement nailed to flat edge
of cripple with 10d f 0.128"x3.0") nails at 6" o.c. "T' or scab must be 90% of cripple length.
Cripples over 10'-0' long requre two CLR's or both faces w/ "T" or scab. Use stress
graded lumber 6 box or common nails.
,Narrow edge of cripple can face ridge or rafter,
as long as the proper number of nails are
Installed into ridge board
-Install blocking under rafter if sleepers are not used.
-Install blocking under cripples If cripples fall between
lower truss top chords and lateral bracing is not used.
-Apply all nailing in accordance to current NDS require
Nails are common wire nails unless noted otherwlse
Fl•••r�`vLf YJ�
eAlLWMSHwa M D Ataa 'M AL ALL TRACT (IN THIS DRAvnai � 4
TAMe ARKNN THIS BRAVING li ALL ALLmaTCrots TMSDOMMMMDRA Tdlt: ySra-� • _
IYV. / vo : c
.
TC LL 20
30 40 54
REF VALLEY FRAMING
•w.
Trusses require ext v care In fabrkatbq, handling, shlpphng, InstallUhr�p and bwchp Refei 1�n M
the latest edition of BCSI (Budtdkp Component Safety IM'ornotlan,'by TPI and SBW f6i; tip.
practices to these functions. Installers
y
7f
; °
3
TC DL 10
20 7 7
DATE 10/01/14
prior perfornft shall provide tenporory bracing pey BCSI.
unless noted otherwise, tap chad shall have properly attached structural ehentNno arW bot an chow
shall have a prOWAY attaOrod Mold cHlnp. Locations sham fort laterol •
OF •
STATE �
BC DL 0
0 0 0
DRWG VACNV1801015
&L-MNfoliow
IE
restrnlit yf
have brackV Installed per BCSI sections B3, B7 or BIO, m applkable. ApplQf truss and position as shown above and on the Joint Detals, wAess noted ather.lse. s
Q ,Z
.�O�•Refer
LL 0
0 0 0
to dmwkVs 16GA-z for standard plate positions. .
Alpine;a division of ITV Mali fg Components-
mow Inc.D,a shall not be respanr for any devhtdonri'
• . �/ .BC
•••� O R, e• +� •�`PA�NY
••eY»e•••• ��
this dra mkq, any falure to burld the truss ti corMornonce with ANSI/TPI 1, or far harxliq, .++bdno.
Installation
\ d
TOT. LD.30
50 47 61
i bracing of trusses.
A seal .n theroddrovft .r cover pagr llsfJnO this dmwkp. Indicates acceptance of profe..lval
er�F,eer},o solely for the shown The use1
b"hp—
fee }s h. "oF`�
` �A
S�oNAL �� ��,
DUR. FAC. 1.25/1.15
13369 Lakefront Drive
Earth City, MO 63045
—y rv¢tvv r.:�eaty Burld•,g De-iw' ANS TK sew
jor more Infra-natlon see tits Job's general notes ppnage marl these web sdtesr
ALf .M..r wnalphneltw.con Tpb www.tphstarph Seca www,sbdndusiryargl ICD www.krsafearg
6 �� -
SPACING SEE ABOVE