STATE
OF FLORIDA
DESIGN
CRITERIA:
CERTIFIED BUILDING CONTRACTOR:
-nam BMING CODE, RESMEN a,
7TH EDMON (2020)
-ALL LOCAL AND STATE CODES
DR HORTON
HOMES
-OCCUPANCY
- RESIDENTIAL, GROUP R3
1430
'CULVER DRIVE NE
-CONSTRUCTION TYPE
-MIN. INTERIOR FINISH
- VB
- CLASS B
PALM
BAY, i, L 32907
-BASIC WIND SPEED
- vult=160 MPH
Vasd=124 MPH
TEL:
(321) 733-7092
-EXPOSURE..
- C
FAX:
(321) 733-7972
-I—STORY RESIDENCE
_2-STORY RESIDENCE
—
- MAX. HEIGHT AS PER L(
AND STATE CODES
STATE
OF 'FLORIDA
SQ.FT. CALC.'S
PROFESSIONAL ARCHITECT:
MICHAEL C. ANDERSON
AR No. 17305
A.B. DESIGN GROUP, LLC
2194 HWY AlA, SUITE 301
INDIAN HARBOUR BEACH, FL 32937
Tel: (321) 802-3591
DRAWING / CONTRACT DOCUMENT
REVIEW BY BUILDER
THE BUILDER ASSUMES ALL LIABILITY FOR
INTERPRETATION OF THE CONTRACT DOCUMENTS.
IF ANY ASPECT OF THE CONSTRUCTION (AS
DESCRIBED IN THIS DRAWING SET) ARE 'UNCLEAR AND
IN NEED OF FURTHER DETAILING OR EXPLANATION IN
ORDER TO BUILD THIS PROJECT BASED ON THIS
DRAWING SET, THE CORRECT PROCEDURE IS FOR THE
BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR
INFORMATION) TO THE ARCHITECT OR ENGINEER FOR',
CLARIFICATION.
AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN
RFI's IN WRITTEN/DRAWN FORMS IN A TIMELY
MANNER. AB DESIGN GROUP- TAKES NO
RESPONSIBILITY FOR INTERPRETATIONS OF
CONSTRUCTION BY THE BUILDER WHEN NO RFI'e HAVE
OEEN GENERATED FOR UNCLEAR ASPECTS OF THE
"r> WSTRUCTION BASED ON THE DRAWING SET.
LIVING
GARAGE
ENTRY
LANAI
1612 SQ. FT.
432 SQ. FT.
38 SQ. FT.
96 SQ. FT.
TOTAL 2238 SQ. Ft.
A/C VOLUME 14381b CU_ FT.
ABBREVIATIONS
1;
REVISIONS
ABV. ABOVE LAV LAVATORY
_
DATE
DESCRIPTION
NC
ADJ.
AIR CONDITIONING
ADJUSTABLE
LUM.
M.C.
LUMINOUS
MEDICINE CABINET
0I/08/113
BID SET ISSUED
01/15/18
2011 F$C UPDATE
ALT.
AMP..
ALTERNATE
AMPERAGE
MFR. '
MIN.
MANUFACTURER
MINIMUM
019/18
_
E31p SET teE ISSUED
BD.. BOARD M.T. METAL THRESHOLD
CL
CENTERLINE
MTD.
MOUNTED
-
CAB.
CABINET
MTL.
MF.TAI..
0411848
FOOTING REVISION PER M. SOWES
CLG.
CLR.
CEILING
CLEAR
N.T.S.NOT
O.C.
TO SCALF.
ON CENTER
02n249
PLAN MAINTENANCE
03/28/19
REVISED LINTEL SIZE AT FRONT ENTRY DOOR
CONC. CONCRETE PL PROPERTY LINE
CPT_
CARPET
P.B.
PUSHBUTTON
aT.
D.
CERAMIC TILE
DRYER
PH.
PLT.
PHONE
PLATF.
04/24/1g
ADDED ADDITIONAL RECEPTACLE IN GARAGE PER WILL BATSON
04/24/19
REVISED HVAC VOLUMES ON SQFT CALC SCHEDULE
DBL. DOUBLE PLYWD. PLYWOOD
-
D.G.
DIA.
DUAI. GLAZED
DIAMETER
PR.
P.T.
PAIR
PRESSURE TREATED
0612149
ADDED LED LIGHTS a KITCHEN t HATHROOMS PER MARK 50WES
DIM.
DISP.
DIMENSION
DISPOSAL
R.
RAD.
RISER'.
RADIUS
01/000
REPLACE USP CONNECTORS WITH SIMPSON CONNECTORS
01/01/21
2020 FBC UPDATE
-DP.
DR
DEEP
DOOR
R.A.G.
REF.
RETURN AIR GRILL
REFRIGERATOR
D S DOWNSPOUT RM. ROOM
DTL
DETAIL
R.O.
ROUGH OPENING
D.W.
DISHWASHER
S.C.
SOLID CORE EXT DR
EA.
EACH
S.D.
SMOKE DETECTOR
ELEV.
ELEVATION
S.H.
SINGLE HUNG
EQ.
EQUAL
SHT.
SHEET
EXH.
EXHAUST
SHTHG.
SHEATHING
EXT. EXTERIOR SHWR. SHOWER
F G./FX.
FIXED GLASS
SIM.
SIMILAR
F G. FUEL GAS SL SLIDING
FIN.
FINISH
SL. GL.
SLIDING GLASS
FLR FLOOR STD. STANDARD,!
FLUOR.
FLUORESCENT
SWS
SHEAR WALL
FR.DR.
FRENCH DOOR
SECTION
FTG.
FOOTING
TEMP."
TEMPERED GLASS
GA.
GAUGE
THK.
THICK
GAR. DISP:: GARBAGE DISPOSAL T.O.C. TOP OF CURB
G.F.I.
GROUND -FAULT CIRCUIT
T.O.P.
TOP OF PLATE
INTERRUPTER T.O.S. TOP OF SLAB
GL.
GLASS
TYP.
TYPICAL,
GYP. BD. - GYPSUM BOARD U.N.O. UNLESS NOTED
H.B.
HOSE BIB
OTHERWISE
H.C.
.HOLLOW CORE
V.P.
VAPOR PROOF
HDR.
HEADER
W.
WASHER
HGT.ORHT
HEIGHT
W/
WITH
INSUL. INSULATION WD. WOOD
INT.
INTERIOR
WDW.
WINDOW
W/H WATER HEATER
W.I.
WROUGHT IRON
eIu❑oo apnI •as
]uaW,l.'edac BuI111W{ad.
'ZDZ 8 9 AdW
03A1309V
Reviewed for Code
Compliance
Universal Engineering
Sciences
INDEX OF DRAWINGS
ARCHITECTURAL SHEET # DESCRIPTION
PG
Cl—COVER
SHEET
PG
GN—
GENERAL NOTES
PG
Al —FLOOR
PLAN
PG
A2D-ELEVATION
"Drr
PG
E1-ELECTRICAL
PLAN
PG
P1-PLUMBING
PLAN
PG
M1—MECHANICAL
PLAN
PG
D1—DETAILS
PG
D2—DETAILS
PG
WAl—WALL
ASSEMBLY
DETAILS
PG
WA2—WALL
ASSEMBLY DETAILS
PG
WA3-WALL
ASSEMBLY DETAILS
2194 HWY A1A, SUITE 301 4
INDIAN HARBOUR BEACH, d
FLORIDA 32937
PH:321-802-3591
www.abdesigngroup.com
AA #: 0003325
.
-.
I
a
Apo
\\e
UHDIV. 8a LrOT:
CREEKSIDE
PHASE 2
LOT ##25
Z OMDEL,:
4EAB
"1672- ARIA"
GARAGE SWING:
RIGHT
PG
WA4—NOT USED
PAGE:
PG
WA5—NOT USED
COVED.
PG
WA6—WALL ASSEMBLY DETAILS
SHEET
DESCRIPTION
I lr ! H EXP. C
STRUCTURAL SHEET
6_ ,a
PG
S1-FOUNDATION' PLAN
ARCFiI`fECT--
PG
S1.1A—DETAILS
a STATE OF FLORIDA
PG
S1.2-DOWEL PLAN
PG
S1.2A—DETAILS
P � l
PG
S2-LIFT BEAM PLAN AND NOTES
PG
S2.IA-DETAILS
MAR t9 2021
PG
` S2.2A—SAFE LOAD TABLES
PG
S3—FRAMING PLAN
MICHAEL C. ANDERSON
L
PG
S31A DETAILS
AR NO 1730 5
PG S3.1B-DETAILS
PG
PG SN1 - S
DETAILS
PRINT °ju
DATE: 0 S 17 21 AkSCALE: 1/4"=1'-0" O
Ii SHEET
Lv
AV
GENERAL NOTES
SITE WORK TIMBER
1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENTIAL(FBCR)
1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT), 1. ALL WOODS AND
WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED
7th EDITION, (2020) . ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED IN THESE DOCUMENTS ARE
UNDER
HEREIN:
FBCR 7TH EDITION (2020) UNO.
2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES,
AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL)
SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES. THE SOILS REPORT AND CIVIL
NATIONAL FOREST PRODUCTS ASSOCIATION:
2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR
DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL
I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION
BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY
FINISH GRADES, PLANTING AND IRRIGATION.
SOUTHERN PINE INSPECTION BUREAU:
THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS, THESE OPENING PROTECTIONS
SHALL
BE
I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER
DESIGNED AND INSTALLED IN ACCORDANCE WITH FBCR 2020 CHAPTER 3, SECTION R301.2.1.2.
3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE
TRUSS PLATE INSTITUTE:
ARCHITECT,
I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI 1-2014)
3. DO NOT SCALE DRAWINGS, THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TOW
RK
E.
APA - THE ENGINEERED WOOD ASSOCIATION:
PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND
4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN''/z THE HORIZONTAL
I. ENGINEERED WOOD CONSTRUCTION GUIDE
DISTANCE FROM THE NEAREST EDGE OF THE FOOTING.
AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS
4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTENTION
OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE
WORK.
5. ALL BACKFILL AT STRUCTURES SLABS.' STEPS AND PAVEMENTS SHALL BE CLEAN GRANULAR FILL. PLACE IN 8" LAYERS 2. ALL LUMBER EXPOSED
TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED.
THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS, DISCREPANCIES DROMISSION
IN THE
AND COMPACT TO 95% MAXIMUM DRY DENSITY DETERMINED IN ACCORDANCE WITH ASTM D1557-2012E1THE
CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTIO
AND
.
OR 3. MINIMUM NAILING
BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS,
PER CHAPTER 6- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS.
FABRICATION OF THE WORK.
4. NOTCHING OR
CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION.
5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TEC
NIQUES
6. COMPACTION BY FLOODING OR JETTING IS STRICTLY'PROHIBITED.
OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUI
ED CODES.
5. WALL SHEATHING
SHALL BE PER STRUCTURAL, SEE ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1.
7, DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE)
6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CONTRACI
OR 6. MINIMUM DIMENSION
OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT . SQ.
SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING
8. EXCAVATIONS TO BE A MINIMUM OF 3' 0" BEYOND NEW FOOTING LINE.
CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED.
PLUMBING
9. THE GENERAL CONTRACTOR MUST TAKE MEASURES' TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE 1. SANITARY LINES
SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL.
TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS.
7. DETAILS SHOWN ON THE DRAWINGS ARE2.
REQUIREMENTS. WATER SUPPLY
INES SHALL BE P C VC OR UPONOR PEX "A" (CROSS LINKED POLYETHYLENE) WITH F1960 FITTINGS.
'
3. CONDENSATION
LINES SHALL BE MINIMUM 3/<" PVC (SCHEDULE 40), INSULATED WITH'/z' AMAFLEX.EER.
8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGIN
1-0. CONTRACTOR IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY 4. SHOWER HEADS
SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF GPM EACH.
WHICH COMPLIES WITH ALL LOCAL CODES HAVING JURISTICTION, INCLUDING ALL APPLICABLE STATE, CITY AND 5. ALL CLEANOUTS
SHALL BE FLUSH WITH GRADE
9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED,
COUNTY BUILDING AND ZONING CODES.
6. NO VENT STACK
SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES,
GARAGES AND CARPORTS
7. SIZE AND LOCATION
OF CLEANOUTS SHALL CONFORM TO FBCR SECTION P3005.2
11. SWIMMING POOL, DECK; SPA, AND ASSOCIATED �/ORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP 8. FIXTURE SUPPL
SIZES SHALL CONFORM TO FBCR SECTION P2903.
1. GARAGE DOOR
i
DRAWING. 9. THE PLUMBER IS
TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE.
A. ENGINEERED FOR MIN. WIND LOAD, LISTED ON COVER SHEET
B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER
10, DRILLING & NOTCHING
OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF FBCR SECTION P2603.2.
12. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES,
C. DETAIL TORE ATTACHED TO PERMIT PACKAGE BY BUILDER
BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION EXTERIOR WALL COVERINGS
I G
2. AS PER SECTION R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING
LABELED FOR USE AS A PREVENTATIVE TREATMENT TO NEW CONSTRUCTION. UPON COMPLETION OF THE 1. ALL EXTERIOR
ALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR
HER' OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED
PURPOSES SHALL NOT BE PERMITTED: 0 GS
41TH
APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THETHE WALLS FOR
COMPONENTS AND CLADDING LOADS IN ACCORDANCE WITH FBCR TABLE R301.2 2 AS MODIFIED BY FBCR
)
SOLID WOOD DOORS NOT LESS THAN 1 3I8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT
3/
ESSTHAN
BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: TABLE R301.2 3)
( ,
MANUFACTURED SOFFITS SHALL BE TESTED AT 1.5 TIMES THE DESIGN PRESSURE
1 318 INCHES THICK, OR 20-MINUTE FIRE -RATED DOORS:
THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREV'ENTION OF SUBTERRANEAN TERMITES.
TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF EXTERIOR FINISHES
3. AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING
HE
AGRICULTURE AND CONSUMER SERVICES." 1. WHEN PLASTERI
qG WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, /aTHICK, " OVER FRAMED WALLS
DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO.26 GAGE (0.48 MM) SHEET STEEL V MINRIG][
APPLIED OVER PAPER
BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS
ON -METALLIC CLASS OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS IN
0 THE
THAN 2 COATS, 1/2"
THICK, WHERE APPLIED OVER MASONRY OR CONCRETE,
GARAGE.
2. STUCCO OR POF
TLAND CEMENT PLASTER SHALL BE INSTALLED, PROPORTIONED AND MIXED IN ACCORDANCE WITH
ASTM-C926-18b;
STM-C1063-19a & ASTM-C1787.
4. AS PER SECTION R302.6 & TABLE R3D2.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC
EA
BY NOT - 3. LATH & ACCESO
IES PER ASTM-C 1063 19a & R703J.1. ALL STUCCO APPLICATION DETAILS INCLUDING BUT NOT LIMITED T0:
LESS THAN'/INCH GYPSUM BOAROOMS SHALL
RD APPLIEDTO THEGARAGE SIDE. GARAGES BENEATH HABITABLE
E
ALLST S
CONTROL JOINTS KICK -OUT DETAILS
SEPARATED FROM ALL HABITABLE ROOMS ABOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIV
LEN
' -- "L" FLASHING
ING -- HORIZONTAL LATH AND PAPER DETAILS
WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO
PIPE PE
qETRATION DETAILS Revewedfor Code
VENT PENETRATION DETAILS
PROTECTED BY NOT LESS THAN 1/2-INCH GYPSUM BOARD OR EQUIVALENT.
WEEP $
oomp"l co
REED DETAILS 91 universal Engineering__ CONDUIT PENETRATION DETAILS
_.
CASING
Sciences
BEAD DETAILS DRIP EDGE DETAILS
-
CANTILEVER
DRIP EDGE DETAILS CORNER BEAD DETAILS
WINDOW
CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS
WINDOW
FLASHING DETAILS
4. SHALL BE INSTALLED
li
PER ASTM-C1063 -19a AND R703.7,
FIRE RESISTANT C014STRUCTION
UNDER STAIR PROTECTION:
1. ENCLOSED ACCE
SSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED
ON THE ENCLOSED
SIDE WITH 1/2" GYPSUM BOARD. R302.7.
a
EXTERIOR CEILINGS
1. EXTERIOR CEILING
TO BE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING
MEMBERS. THE
/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1
1/4" TYPE "W" DRYWALL
SCREWS AT 12" O.C. (PER MANUFACTURER'S SPECIFICATIONS) .
CONSTRUCTION OBSERVATION
CONSTRUCTION OBSERVATION
SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT'A PART OF AB DESIGN GROUP'S
SERVICES FOR THIS PROJECT.
IT IS UNDERSTOOD AND
AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW
OF THE BUILDER'S/CONTRACTOR'S
PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL
BE PROVIDED BY THE BUILDER
THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS AND
FOR CONSTRUCTION OBSERVATION.
CONTROL DATE: 12/10/20 (RM)
2194 H WY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www. a b d es i g ngrou b. Com
AA #: 0003325
�T.. ,.:ss�
tj
uj
z
r
as ry
N7,'U33DIV revL.O.T. ,
CREEKSIDE
PHASE '2
LOT #25
PROJECT#
04321.200 025R1
MODEL:
4EAB
"1672-ARIA"
6F
GARAGE SVfMG
RIGHT
l
PAGE:
GENERAL
NOTES
160 MPH EXP. C
ARCHITECT:
STATE OF FLORIDA
MAR 19` 2021
MICHAEL C. ANDERSON
O NO 17305
f
NT
TE: 03/17/21
LE:1/4„ 1'-0"
EE'.
G,
GROUND
WIND DESIGN
SEISMIC
SUBJECT TO DAMAGE FROM
WINTER
ICE BARRIER
FLOOD
AIR
MEAN
SNOW
SPEED
TOPOGRAPHIC
DESIGN
WEATHERING'
FROST LINE
TERMITE
DESIGN
UNDERTLAYMENT
HAZARDS 9
FREEZING
AN AL
LOAD
(MPH)
EFFECTS"
CATAGORYr
DEPTH`'
TEMP'
REQUIRED'
INDEX
TEMP!
NA
Ih0 G
I NA
INEGLIGABLE
I NA
I VERY HEAVY
42
1 NA
ISEE SURVEY
NA
NA
FLAME SPREAD AND SMOKE INDEX FOR WALL AND CEILING FINISHES SHALL BE IN
ACCORDANCE WITH SECTION FBC R302.9.1 THROUGH FBC R302.SA .
FLAME SPREAD AND SMOKE -DEVELOPED INDEX FOR INSULATION SHALL BE IN
ACCORDANCE WITH SECTION FBC R302.10.1 THROUGH FSC R302.105
12'-0" 2 _8`
}
(2) 3052 ^SH
I-------------`�
-- J
O
C
41 I
LANAI
a' -a' CLG. Q
1
DINING
ROOM
BDRM,#1
�p 1
8'-8' CLG.
6 I
Litj (2) 3052-SH
nj..'
rn
17'-6"
3 -4" 3'-1011 6'-6"
GREAT ROOM
8'=8' dLG
I li��---�` 9 I
W.I.C.
8'-8' CLG.
?
m
e cp a A
O
I
u
B
KITCHE
Ub� 81-8' CLG,
WC
Ai
12'-8°
4 _4
3'-8" 3'- it 3'-ON
-
3' 10" 3 0 3 -/ 1I
11 !i I
Q�SJ
I
a,
F 771
Imo'
BDa c 3
IGA1�1
I
3-sH
BATH #1
I r—n IN
?.8
G.
4 6 _411
5'-4°
CII ry,47
I I AI
M11 I I
�'
i ----�1
V.
ry 8
3-SH
III
`� -_y
SHWR. PAN
LAV. W/ ENCL
o------
LAUN. O
8'-8' CLG. WH.
1- �z ATTICI
IR-1SH
•� I I
BATH #2 1 1 1
8' 8' CLG. ,y' I S I I
L L- J
j 114_
V
1ACCE
N
V. Al
II
e II
WC. ® II
BOLLARD
AS REQ.
J
1R-ISH _
PER BLDG.
------ en V.
m
--
CODE
\.� _
ro
FOYER
�. .�
8'-8' CLG.
GARAGE
a,-8' CLG.
6'-S" 2'-4" 3'-8"
❑1
3068 W/
36"XIV TRANS.
C
1 k
M.T.
BDRM.#2
CLG.
ENTRY
(2) 3052-SH
EGRESS
LLlE
—
---
U
0
�,' -----J
—_L----------
—
U
Q.A,,..,,, r
Vrk,l_s
i
. '. `r.i5x=
_
t.
4
GABLE ROOFS
11" < 0 z.� 43'
Ft:rSi Et x aipl BEii:, i.c,c `.,(),t475swd.
r
H x
F
..... ^.. t t I. .. w......t ...i.
" __44..
€CIF ROOFS
.• ,no S t . L.»5.0.
FIGURE R301,2€7
COMPONENT AND CLADDING PRESSURE ZONES
FLOOR PLAN
SCALE: 1/4' = 1'-0'
NOTE: 1
-2-8 LOUV. DOOR W/ AIR HANDLER ON META
STAND OR 2-8 SOLID
DOOR W/ RETURN PLENUM AND RETURN AIR
GRILLE.
- VERIFY CONDENSER PAD LOCATION WITH SITE
PLAN.
-OTHER OPENINGS BETWEEN THE GARAGE AND
RESIDENCE SHALL
BE EQUIPPED WITH SOLID WOOD DOORS NO
LESS THAN 1 3/8' (35
MM) IN THICKNESS, SOLID ORHONEYGOMB-
RE STEEL DOORS NOT
LESS THAN 1 3/8' (35 MM) THICK, OR 20-MINU
E FIRE -RATED DOORS.
- EGRESS NOTE= DO NOT SHUTTER FRONT DO
OP, FRONT ENTRY
DOOR TO BE EGRESS POINT WHEN THE HOME
IS SHUTTERED.
- REFER TO BUCKING DETAILS FOR BUCKING
AND RO NOTES.
-FRAMED WALL SEPARATION BETWEEN THE U14CONDITIONED
GARAGE AND CONDITIONED SPACED SHALL
HAVE AN INSULATION
R VALUE OF R-13
-CEILING R VALUE TO SE R-30 INSULATION AElOVE
CONDITIONED
SPACE-
-FOR CONSISTENCY, THE VOLUME CALCULATIONS
ON PLANS ARE
PROVIDED BY THE HVAC CONTRACTOR AND
ARE OF THEIR
CLOSEST ALLOWABLE SOFTWARE TOLERANCES.
OPENING INFORMATION BELOW IS DIRECTLY
FROM THE PLAN SET.
U VALUE AND SHCG ARE INFORMATION PRO
IDE;D BY THE
MANUFACTURER AS LISTED IN THE RESPECT,
PRODUCT
SPECIFICATIONS
OPENNCs
OVERHANG
sEPARAT'ION
U-VALUE
&We-
1
0'-10,
32
25
2
I'-r1D'
m'-9'-
35
29
4
13'= '
1'-4' ;
.63
32
r'
w4p,
01-9'
35
29
&
1'-aI
0'-9'
35
29
Ili
1'-0'
S'-4'.
35..
29
EXTERIOR MASONRY
WALL BRCS. HEIGHTS
BRCS. xi
10'-8' B�Rrs
SQ.FT.
CALC. S
LIVING
GARAGE
ENTRY
LANAI
1612
432
38
96
SQ. FT.
SQ. FT.
SQ. FT.
SQ. FT.
TOTAL
2238
SQ. FT.
A/C VOLUME
14381.E
GU. FT.
RD C lcm WI'D LOADS
BASIC WI=D EXPOSURE FOR 3 MOM O.I1SI8
oPElm
AND TYPE
"0 11 E
FOOTAGE
ZOIE
teo IrPH WIND pnlll
I�r1ARKs
MIN. WINDOW
CRITERIA
10
5
34/-45
EXTERIOR SWING
18
5
33/-43
r
DR. MIN_ CRITERIA
S.G.D. MIN.
41
5
31/-39
CRITERIA
_.m
16010 O.H.D.
112
5
282/-31B
II iVAV SOFFIT
I I
I
5
313/-49.9
BASIC WIND SPEED MPH = 160 (Vult)
INTERNAL PRESSURE COEFFICENT = f 0.18 BLDG.
CAT.=II, EXP.=C, MEAN ROOF HT. = 13'-0"
�I
PRESSURES HAVE BEEN MODIFIED PER FBCR 7TH ED.
(2020) SECTION R301.2.1 TO MEET TESTED ALLOWABLE
OR NOMINAL WIND LOAD VALUES FROM THE PRODUCT
MANUFACTURER. COWIXX DAIS OW21
NOTE:
SOFFIT INSTALLATION IS TO BE PER
MANUFACTURER'S SPECIFICATIONS
THAT ARE TO BE PROVIDED BY THE
BUILDER WITH PRODUCT APPROVAL
AND NOA SUBMITTALS.
Reviewed for Code
Compliance
Universal Engineering
Sciences
Q
0
0
LL
ARCH DTL.
TOP
PLATE
SLisDIV 8e LOT
CREEKSIDE
PHASE 2
1
LOT #25
PROJECT#
04321.200 0215R1
MODEL
4EAB
"1672—ARIA"
e
GARAGE SWING:
E`
RIGHT
PAGE:
I
FLOOR
t
PLAN
STAB �F F, , �, �
MAR 19 2021
MICHAEL C. ANDERS' ,I'
AR NO 17305
I
C21 PRINT 03 17
DATE: l
BAR DETAIL SCALE:1/4"=1'-0„
SCALE: 1/2' =1' -O' SHEET
AI
d
SHINGLE
S'-B" ERG. HCYT
1' - 011
FYPON
BKTIIX17 OR
EQUIVALENT 4B
A
4' RAISED TYP.
BAND (TYP.) r
m'-m" FIN. FLR.
a, -all BRG. HC
O'-m" FIN. Fl-
s
1
BLDG. NC:T.
FYPON LV12X24
�TEQ EC?. OR EQUIVALENT
0
I
FRONT ELEVATION
O TEXTURE6
NOTE: WALL FENESTRATION • AS — FRCR 103.4
T.
I
48 I
A
TYP.I I
II
0'-0" FIN. FLR:
11N. 4" GsRADE
v
OFF RIDGE VENT
6' RAISED
BAND (TYP.)
BRCS. HGT.
OPT. COACH
LIGHT
9
A
a0'-0" FIN. FLR.
OFF RIDGE VENT
8'-S" ERG. HGT.
— ( — -
m'-®" PIN FLR.
12
6
w� 7iFIE]
Ell
El
-------------------
DEAR (ELEVATION
SCALE: 1/4 = I'-®' TEXTURED FINISH
■ )21-411
N
O'-O" FIN FLR
- - - - - - - - - - - - - - - - - - --- - - - - - - - - - - - - - - - - - - - ---
IGHT
ili 7r-1 T-1 r " T 1 -Wr 11r1 T 7 ■ +Ylrl lr ! w T
ELEVATION
TEXTURED FINISH
Reviewed for Code
Compliance
Universal Engineering
Sciences
ERG, HGT.
,O'-O" FIN. FLR.
f 1
LOUVER DETAIL
A SCALE: I/2 I'-(D'
MODEL 1672-ARIA
AREA OF ATTIC = 2318 SQ. FT.
NET FREE VENTILATION AREA
REQUIRED 1/ 300
REQUIRED VENTILATION AREA = 2318 /300
7.73 SQ. FT.
7.73 1112.64 SQ. IN.
MIN. REQUIRED VENTILATION IN = .4X 1112.64
UPPER PORTIONOF ATTIC - 445.056 SQ. IN.
(BALANCE'TO BE PROVIDED IN
SO'FFITVENTS)
OFF RIDGE VENTILATION AREA _ 138 SQ. IN. PER VENT (net free area)
TOTALttOFVENTS REQUIRED = 3.23
TOTALftOF VENTS PROVIDED 4
SOFFIT VENTILATION AREA 7 SQ. IN. PER LINEAR FT (net free
area)
LINEAR FEETOF SOFFITREQUIREC 63.58
LFLORIDA32937
WY A1A, SUITE 301
HARBOUR BEACH,
321-802-3593
bdesigngr0 pomA #: 0003325
I
1
q
S
MV. 8e LOT:
REEKSIDE
r�P
HASE 2
LOT #25
PROJECT#
04321.200 025R1
MODEL:
EAB
16
�,-ARIii'
GARAGE SWI
RIGHT
PAGE:
Ir,
�y
ELEVATION "D"
160 MPH EXP. 0
ARCHrrECT:
STATE OF FLORIFDA
L
AR I n 7EL C AN
PRINT
DATE: 03/171
[! SCAT E:1/4' l',-0"
SHEET
MWO
ELECTRICAL LEGEND
SY1'180L
DEFINITION
NOTES
125V OUTLET
20 AMP SINGLE F !. E
"
110V OUTLET
110V OUTLET
1O OF WILD
TO SWITCH
'&
,--�-7 GPI
'm
110V OUTLET
E�IPED W/GI�1D FAUL
MTERUFIMM (TAMPER
RESISTANT TYPE)
:�.
220V OUTLET
(4) WIRE CONNECTION
T. WATERPROOF
F FAULT
GFI
OUTLET
INTERMPTEGROUND
SWITCH
SWITCH
3-WAY OPER
!t4
SWITCH
4-WAY OPER.
�-o
WALL MOUNTED
I�
LIGHT
CEILING LIGHT
. nA..._
L
LED CLG LIGHT
O VP
LED VAPOR
PROOF LIGHT
r
VP
VAPOR PROOF
LIGHT
ORECE65ED
CAN
eVENT.
FAN
I CFM PER SQ. FT.
VENT. FAN
W/LIGHT
1 041 PER $R FT.
VANITY
FIXTURE
(SPEC'S TBD BY
BUILDER)
FLUORESCENT
2-BULB WRAP
LIGHT
AROUND
(RECESSED)
4 X2
FLUORESCENT
2-BULB WRAP
LIGHT
AROUND
D
u
(SURFACE MINT-)
2' FLUORESCENT
...
4' FLUORESCENT
..
-a-,gy-
4' TRACK LIGHT
x
i.
I
PANEL
r
! m z
METER
--
S.D.
BATT BACK UP �.
W/ HARDWIRE
-�
(SMOKE DETECTOR
WALL MOUNTED
SMOKE DETECTOR
MATT. BACK-UP
W/ HARDWIRE
MATT. (BACK-UP W/
® S/GO
CARBON MONOXIDE
SMOKE DETECTOR
CIOM50
HARDWIRE
INTER -CONNECTED
SHALL BE A DISTANCE
OF NOT LESS THEN 4'
FROM WALL
PENDANT LIGHT
I_I^�
NATURAL GAS
FV
OUTLET
TELEPHONE JACK
WATER HEATER
IGNITION SOURCE
TO BE ELEVATED
DISCONNECT
A/
AIR CONDITIONING
SEE AFNJ -UND.
DISCONNECT
THIS SHEET
I-�
TELEVISION JACK
CEILING BOX REQUIRE
OJ-BOX
TO ME SUPPORTED IN
ACCORDANCE W/ SOX
MARKED AS SUCH FOR
INSPECTION
CEILING BOX REQUIRE
TO BE SUPPORTED IN
C%
CEILING FANLIGHT
ACCORDANCE W/ BOX
MARKED AS SUCH FOR
INSPECTION
24' INCANDESCENT ".
•�
LIGHT STRIP y
3&1 INCANDESCENT
LIGHT STRIP
ononnnnn
INCANDESCENT
LIGHT STRIP
y
®
FLOOD LIGHT
OPT. SECURITY
KEYPAD
,
P118H-BUTTON
FOR CHIMES
USM PORT
• LOCATION OF TV JACKS 4 PHONE OUTLETS 4 FANS TO
BE VERIFIED • HOMEOWNER PRE -CONSTRUCTION
MEETING.
• ALL 15 4 20 AMP BRANCH CIRCUITS TO BE ARC FAULT
PROTECTED PER ELECTRICAL PROVISIONS OF P5CIR
ITH EDITION (2020) 4 NEC 21012 201T EDITION.
• 20 AMP DEDICATED LAUNDRY CIRCUIT.
• GFI a ISLAND (NOT ON KITCHEN CIRCUIT)
• DISHWASHER DISCONNECT TO BE LOOKOUT IN PANEL
• BATHROOM EXHAUST FAN TO HAVE MIN. CAPACITY OF
50 CFM INTERMITTENT PER ELECTRICAL PROVISIONS OF
SECTION M159"3 FBCR TTH EDITION (2020).
• LAUNDRY ROOM RECEPTACLE SHALL BE GROUND
FAULT CIRCUIT-INTERFUPTER PROTECTION FOR
PEi2SCHISEL ON FEEDERS
• WIRING METHOD SHALL BE NON METALLIC CABLE PER
ELECTRICAL PROVISIONS OF FBCR TTH ED (2020).
• ALL WOW, TO COMPLY WITH ELECTRICAL PROVISIONS
OF THE FBCR 7T14 ED (202p).
• ALL LAMPS SHALL BE SELECTED BY &ILDER AND
T5% OF LIGHTING MUST ME ENERGY EFFICIENT TYPE PER
EFFICIENCY) 2020, Tth EDITION R404.1
CEILING PRE -WIRED
MTD. LIGHT CLG FAN+
TO SE
(INSTALLED, `Iy
PROVIDE
J-SOX FOR\
OPT. FAN LANAI
.11
_ o
DINING
ROOM
PRE -WIRED
OUTLET
.GFI
\
FOR DW -- —�
GFI Ll
GLG FAN SWITCH IN 1
J N CABINET
KITCHEN
GREAT. R00 \
1
1 L —_��
GFI
I 1
BDRM. 3 _ = - - = \
I
s, I
LAIC
BDRM.#1
PRE -WIRED
CLG FAN
HOOD WIRE W/
D. OUTLET FOR
Q UTURE MICRO. qP
7A I
/ W.T.C.
4 -
--- I
L
i
GFI
J LAUN -
(�,)�
CLG FAN
BATH #R
BATH .gi
• ; III 1 .
❑
GR - -
74)
"'r I -
I GFI ,o� I!�
/ I GARAGE 1 44 AFF. F WH AFF.
1 DOOR 1
l 1 \ L___LI
\ \ Z5OLLARD OND
\ \� 2WALL MOUNTED AS REG2.
LIGHT W/SWITGH IN PER SLOG.L
ATTIC CODE
$ ;KEYLESS
Q� I FOYER FIXTURE
I
_.
fxFl METER
D. CLG. z FIELD
Q VERIFY
BDRM #2 � ouTLET 4 [- LOC.
OWD IRRIGATION
/ ^) P.S. FOR ❑ — ❑ OUTLET m
CHIMES , \ 48' AFF.
:ENTRY
1 GARAGE GFI
F'RE-WIRED
CLG FAN I GF
(� I
OPT -COACH
_—_—_—__ LIGHT
ELECTRICAL PLAN
SCALE: 114" = P-O'
PANEL: 8/16 wp crt. breaker
FEEDER :3-#1
W P Panel MAIN - A'
VOLTAGE: 120 / 240 V -1 Ph MAIN; 150 Amp M.C.B
uTHWN&1-#6Cu(G)in11/2"C. OR 3 #2/0IALTHWN&1-#6Cu(G)in11/2"C.
Wire
Pole
Bkr
Description
Watts
Circuit
1
Circuit
Watts
Description
Bkr
I Pole
Wire
#12
1
20
1 Exterior Receptacle GFI for TM
1200
1
2
Space
#12
2
20
1 Irrigation Pump
1000
3
4
Space
30.
F2
#10
4680
A/C C.U.-1
Space
7
8
PANEL: 4 breaker 2 crt.
FEEDER: 3-41
PANEL - A
VOLTAGE: 120 / 240 V -1 Ph MAIM 150 Amp M.L.O.
CuTHWN & 1-#6 Cu(G) in 1 1/2"C. OR 3-#2/0'ALTHWN&1-#6Cu(G)in11/2"C.
Wire
Pole
Bkr
Description
Watts
Circuit
Circuit
Watts
Description
Bkr
Pole
Wire
# 12
1
20
Small Appliance
1500
1
2
8000
Range
50
2
#6
# 12
1
20
Microwave / Hood GFI
1800
3
4
#12
1
20
Small Appliance
1800
5
6
4500
Water Heater
25
2
#10
# 12
1
20
Refrigerator GFI
1500
7
8
#12
1
20
Dining Receptacles AFCI
1500
9
10
1200
Disposal GFI
20:
1
#12
#12
1
20
Bath GFI Receptacles
1200.
11
12
1500
Dishwasher GFI
20
1
#12
#12
1
20
Foyer / Hall / Laundry AFCI
1200
13
14
16
5000
Dryer GFI
30'.
2
#10
#14
1
15
Great Room, Lanai & Dining Li
hts AFCI
900
15
Space
17
18
20
1500
Washer GFI
20'
1
#12
#14
1
15
SD & C/O AFCI
900
_
19
1000
Garage Door Opener GFI
20
1
#12
#12
1
20
.Bed #2 & #3 / Bath #2 AFCI
1200
21
22
1200
Garage I & Receptacles GFI
20
1
#12
Space
_ 23_
25
_ 24
26
_ 9_00
000
Owners Suite AFCI
15
1
#14
Space
Owners Bathroom AFCI
15
1
#14
Space
27
28
1000
Exterior Lights and Recpt. GFI
20
1
#12
Space
29
- 31
30
32
1000
Irrigation controls only
20
1
#12
Space
--
Space
Space
33
34
Space
Space
35
36
Space
Space
37
38
Space
#8
2
35
A/CAHU-1
(Heater 5.KVA at 65%
5120
39
41
40
42
_
Space
Space
ace
1
Load subject to demand factor calculations / line
15400
27700
Load subject to demand factor calculations / line
Demand Factor Calculations:
ABBREVIATIONS:
AFCI: ARC FAULT CIRCUIT INTERRUPTER
NC: NON -COINCIDENT LOAD
GFI: GROUND FAULT INTERRUPTER
Total load subject to demand factor
43100
First 10000 watts at 100%
10000
Remaining watts at 40%
13240
Total A/C load
9800
10% for future growth
LOAD CALCULATION IS BASED ON A/C NON -COINCIDENT LOAD
Total Connected Load Watts
33040
Total Amps (watts / 240 volts)
137.7
LED LIGHTING
C DOUBLE LAV.
BATH 01
150 AMP ELECTRICAL RISER
NOT TO SCALE.
GENERAL NOTES:
A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL
COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR ITH
EDITION (2020). LOCAL CODES, AND ALL LOCAL POWER
COMPANY REQUIREMENTS.
B. ALL CONDUCTORS SHALL BE TYPE THNN/THLLN UNLESS
NOTED OTHERWISE.
POWER COMPANY
TRANSFORMER
Q.Mt7�
PROVIDE 150 AMP, 120/240 VOLT, I PHASE SECONDARY -
ELECTRICAL SERVICE. PROVIDE 3 h COPPER (CU) IN
1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3
0210 ALUMINUM (AL) IN 2" DIA SCHEDULE 80 PVC
CONDUIT UNLESS SERVICE 18 PROVIDED BY THE
ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC
COMPANY PRIOR TO BID.
Reviewed for Code
Compliance
Ea Universal Engineering
Sciences
LED LIGHTING
P SINGLE LAV.
BATH e2
PROVIDE 342/0 CU, THWTN . 1% CU IN 2' CONDUIT OR 3
04/0 AL, THW 1 . 1% CU IN 2' CONDUIT OR 2/0 AL. S.E.R.
(CONDUIT TO TERMINATE ABOVE SOFFIT • OVERHANG.)
COMBINATION SERVICE 150 AMP
DISCONNECT SWITCH AND 120/240 VOLT
ELECTRIC METER IN I PHASE
NEMA 3R ENCLOSURE MLO
M O
PANEL
150A/1P
MC15
TELEPHONE SERVICE
ENTRANCE
EQUIPMENT
INTERSYSTEM BONDING
TERMINAL AT LOW
VOLTAGE CONNECTIONS
GABLE TELEVISION
SERVICE ENTRANCE
EQUIPMENT
— 1 04 CU SERVICE GROUND CONNECTED TO
CONCRETE ENCASED FOOTER STEEL FIER
ELECTRICAL PROVISIONS OF THE FBCR NTH
EDITION (2020).
5/8" !:)IA X 8 FT LONG COPPER CLAD GROUND ROD
2194, H WY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802 3591
www. a b d es I g ngrou p. com
AA #: 00033251
c�
SUBDIV. 8e LOT
CREEKSIDE
PHASE 2 k
LOT #25
:PROJECT*
04321.200 025R1
it[ODEr.
4EAB
"1672—ARIA"
GARAGE SWING:
RIGHT
PAGE:
ELECTRICAL
PLAN s
MPH EXP. C '
ARCHrrECT
STATE OF FLORIDA
MAR 19 2021
MICHAEL C. ANDERSON
AR NO 17305
PRINT DATE: 03 17 21
SCALE: 1/4"=1'-0"
SHEET
E1
in
a�
6
B
m
m
a
g
PLUMBING PLAN
SCALE: 1/4 = V-0'
TU
KITCHEN
SINK W1
AUTO VENT
1-1/2' VTR
- 0
A.A.V. t
L,4V It
��
(RIGHT ALTERNATE)
PLUMBING RISER
Reviewed for Code
Compliance
Universal Engineering
Sciences
2194 HWY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
sUBMV. & LOT:
CREEKSIDE
PHASE '2
LOT #25
PROJECT#
04321.200 025R1
1�ODEL•
4EAB
"1672—ARIA" N
GARAGE SWING a4
RIGHT
PAGE:
PLUMBING
PLAN
160 MPH EXP C
ARCM CT:
STATE OF FLORIDA
MAR 19 2021
MICHAEL C. ANDERSON
AR NO 17305
so
PE��aTT 03 17 21
nA=:E:
SCALE:
SHEET
PI
5
I
El ri
0
DINING
II � Il
OM
BD
12X12 12XI2
AI
ROOM
RM. 1
I I (
1mX6
12m CFM
—
+_
MOIL— U
IOX6
12m GFM
I
12X5 L
6
6' >�175 CFM
i
j �Lwi it
I
W.I.C. I
- ax4f
GREAT ROOM 10X6 ITCHEN
- 45 CFM
I
tzm cFM
I'
1mX6
ax4
-15 CF
t
5 GFM -
- -- 12' C m
BATH FM
lmx6 L
BDRM. 3 l5 CFM4
lmx6 6'
-1 -- C� II
75 FM �I 4' ---
4 4
4 R �5
8X 4
i
12XB ~- - ----
45 CFMI
PASS
/� 11 THRU
LJ
� I
MASONITE
I 4 LOUV=R
I(BATH 2 I PLANTATION
8x4 a 4' 18m-m4 2 8'
_ 6 MAX A1 R
45 CFI i 10X6 584.15 GFM
15 CFM
Ll
- - PASS -1 GARAGE
- - THRU FOYERi
FOYER
lox
6
�5 CFM
M. 2 BDR f
I
ENTRY
ENTRY
�I �J
HVAC PLAN
SCALE: 1/4 = 1'-0'
Reviewed for Code
Compliance
Universal Engineering
Silences
R-VALUE SCHEDULE
FLOOR
SLAB ON GRADE
R-m
EXTERIOR WALLS
CMU - INT INSUL
R-4.1
FRAMED WD - ADJACENT
R-13
FRAMED WD - EXTERIOR
R-13
CEILING
UNDER ATTIC
R-30
111111
-J-UBDIV. Se LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT#
04321.200 025R1
MODEL:
4EAB
"1672—ARIA"
GARAGE SWING:
RIGHT
PAGE:
HVAC
PLAN
160 MPH EXP. C op
PRINT 2117
DATE: 03 / /
SCALE: 1/4"=1'—O"
SHEET
I
B
PER FLR
PLAN
1/2' CLG.
1/2' DRYWALL
SECURE BT. —
PLATE TO SLAB
W/ 10d MASONRY
NAIL a 32' O.C.
MAX
FIN. FLR.
9VA T/ M CI ATG
JSS
2X4 WOOD
STUDS e24'
O.C.
SLAB
NOTE: STUDS IN
PARTITIONS SUPPORTING
WALL HUNG PLUMBING
FIXTURES AND WALL
CABINETS SHALL BE NOT
LESS THAN 2x4, WHERE
SPACED NOT MORE
THAN 16" O.G. OR, NOT
LESS THAN 2x6, WHERE
SPACED NOT MORE
THAN 24" O_C.
TYP. INT. WALL (NON-BRG.
SCALE: 3/4' =1'-0'
FIBERGLASS SHINGLES
WITH UNDERLAYMENT
AS PER FBCR 905.1.1.
ROOF SHEATHING
THICKNESS AS PER
SHEET SNI. SECURED
PER FASTENER
SCHEDULE
PRE-ENG TRUSS
MTL. DRIP EDGE
2x FASCIA PER -m.
YF.
ELEVATIONS f
VENTED SOFFIT '
1/2' THICK, 2 COAT PORTLAND
CEMENT PLASTER APPLIED
DIRECTLY TO MASONRY
0'-0" FIN. FLR
5/8' GYPSUM 51
OR 1/2' HIGH
STRENGTH CLG.
BOARD
1/2' DRYWALL—`
3 5/8' OR 5 3/5'
METAL STUDS 24' O.G.
20 GA METAL TO BE
INSTALLED IN WALLS
RECEIVING UPPER/
LOWER CABINETS
AND TUB/SHOWER 25
GA. METAL TO BE
INSTALLED IN ALL
OTHER WALLS. STUDS
TO BE SPACED 16'
O_C. AT 2ND FLOOR
WALLS ADJACENT TO
STAIR WELLS AND
BATHROOM WALLS W/
TiLE FINISH
WOOD BASEBOARD —
_J SEE ENERGY CODE FORMS
INSULATION R-VALUES
REFERENCE STRUCTURAL
1 PER ELEVATION
K �—RINSULATION
JIB. lV I� WINDOW
OW ATTACHMENT
V SAS PECIFICATIONS
PER MANUFACTURES
SPECIFICATIONS
REFERENCE
STRUCTURAL
Ix2 P.T. FURRING
STRIPS a 24' O.C.
8' GMU
1/2' GYP. WL. BD.
�— WOOD BASE
1-STORY
TYP. INT. WALL
METAL STUDS
Al (NON-BRG.)
11 / SCALE: 1/2'=1'-O'
3 5/8" OR 5 3/8,
TOP CHANNEL (25
GA.)
1/2' DRYWALL
3 5/8' OR
5 3/8,
BOTTOM
CHANNEL
(25 GA.)
SECURED
t0 CONIC
FLOOR W/
3/4' PAF E
TO WOOD
FLOOR W/
1/4' WOOD
SCREW
INISH FLOOR
BOND SEAM
SOLID GROU1
W/ (I)- S
(2) COURSE
FIBERGLASS SHINGLES
WITH UNDERLAYMENT
AS PER FBCR 905.1.1.
ROOF SHEATHING
THICKNESS AS PER
SHEET SNI.
SECURED PER
FASTENER SCHEDULE
STRUCTURAL
PRE-ENG TRUSS
MTL. DRIP EDGE
2x FASCIA PER
ELEVATIONS
VENTED SOFFIT
— DIA. SLEEVE,
O NOT CUT
EBAR
IPE�
DO NOT CUT
THE BOND
BEAM
REBARS
2AIPIPE THROUGH BOND BEAM
D1 SCALE.3/4"=1'-0"
1/2' THICK, 2 COAT PORTLAND
CEMENT PLASTER APPLIED
DIRECTLY TO MASONRY
0'-0' FIN. FLR.
I� ROOF SHEATHING THICKNESS IS
ENGINEERED PER ASCE 1-16 IN
ACCORDANCE WITH FBCR 2020
NTH EDITION, SECTION R301.13
AND 1609.5.1.
H W WINDOW OPENING B TYP. WALL SECTION
NO OPENING
NOTE:
METHOD TO BE USED FOR THE
-STORY HIP BLOCK WALL INSTALLATION OF ROOF
SCALE: 3/4'=i'-O' UNDERLAYMENT IN ACCORDANCE
WITH FBCR 905.1.1.1 OF THE FBCR
2020 -ITH EDITION iS 1*4 WHICH USES
(2) TWO LAYERS OF ASTM D226
TYPE iI OR ASTM D4869 TYPE III
OR TYPE Iv UNDERLAYMENT.
FIBERGLASS SHINGLES
WITH UNDERLAYMENT
AS PER FBCR 905.1.1.
ROOF SHEATHING
THICKNESS AS PER
SHEET SNi. SECURED PER
FASTENER SCHEDULE
MTL. DRIP EDGE
2x FASCIA PER
ELEVATIONS
VENTED SOFFIT
WALL SHEATHING
THICKNESS AS PER
SHEET SNI. SECURE PER
FASTENER SCHEDULE
ON SHEET SNI
PRE-ENG. GABLE TRUSS
WEEP SCREED
2x P.T. SECURED PER
STRUCTURAL DETAILS
1/2' THICK, 2 COAT
'i ORTLAND CEMENT
PLASTER APPLIED
DIRECTLY TO MASONRY
0'-0" FIN. FLRIL
8' CMU —
ti
9
MA;
CAULK AND VEAL
`GAS LINE
`l J' PVC SLEEVE FOR GAS LINE
—e' Ctiu
—I/1' GYP. UL. 1512.
—WDW DASE
2B GAS LINE THRU BLOCK
D1 SCALE: 141'.1'-e'
--2X4 SPF 24' O.G. MAX.
SECURE W/ (2) 12d NAILS
® EA. END
2x BLOCKING BETWEEN TRUSSES
—PER STRUCTURAL DETAILS-
-STIFFBACK AT ALL UPRIGHTS
- PER STRUCTURAL DETAILS
-PRE-ENG WD. TRUSS
PER ELEVATION
CONT. 2x RAT RUN SECURED PER
STRUCTURAL DETAILS
SEE ENERGY CODE FORMS FOR -
INSULATION R-VALUES
PER ELEVATION
5/8' GYPSUM BOARD OR 1/2' —
HIGH STRENGTH CLG. BOARD
1/1' THICK, 2 COAT -
PORTLAND CEMENT
PLASTER APPLIED
DIRECTLY TO
MASONRY
GALV. STEEL
__
TRACK BRACKETS
FASTENED TO
WOOD JAMB PER
R PODUCT
GALV. 6TEEL....
APPROVAL REEL
VERTICAL TRACK
BY MAUP. SLIDE
FASTENED TO
ROOM
TRACK BRACKETS
W/ PRODUCT
APPROVAL REQ.
R-4.1 INSULATION
WINDOW ATTACHMENT AS PER
MANUFACTURES SPECIFICATIONS
REFERENCE
STRUCTURAL
Ix2 P.T. FURRING
STRIPS a 24' O.C.
1/2' GYP. WL. BD.
WOOD BASE
a, CMU SEE
STFi CTURAL FOR
REINFORCEMENT
2x6 P.T. WD
ATTACHED TO FILL
CELL AS PER
PRODUCT
APPROVAL REQ
SEALANT 4
BACKER ROD
WEATHER STRIP
MOULDING ALL
AROUND MY
DOOR MANUFJ
OVERHEAD DOOR
BY OTHERS
GARAGE DOOR JAMBS
SCALE: 1 1/2 " =1' -O'
Compliance
Universal Engineering
Sciences
FIBERGLASS SHINGLES
WITH UNDERLAYMENT
AS PER FBCR 905.1.1.
ROOF SHEATHING
THICKNESS AS PER
SHEET SNI.
SECURED PER
FASTENER SCHEDULE
MTL. DRIP EDGE
2x FASCIA PER
Ax. ELEVATIONS
VENTED SOFFIT
WALL SHEATHING
THICKNESS AS PER
SHEET SNi. SECURE PER
FASTENER SCHEDULE
ON SHEET SNi.
PRE-ENG. GABLE TRUSS
WEEP SCREED
2x P.T. SECURED PER
STRUCTURAL DETAILS
CMU
0'-0' FIN. FLR
ROOF SHEATHING THICKNESS IS
ENGINEERED PER ASCE I-16 IN
ACCORDANCE WITH FBCR 2020
ITH EDITION, SECTION R301.13
AND 1609.5.E
n W WINDOW OPENING �R TYP. WALL SECTION
Q NO OPENING
NOTE:
METHOD TO BE USED FOR THE
1-STORY GABLE BLOCK WALL INSTALLATION OF ROOF
SCALE: 3/4'=r-0' UNIDERLAYMENT IN ACCORDANCE
WITH FBCR 905.1.1.1 OF THE FBCR
2020 ITH EDITION IS *4 WHICH USES
(2) TWO LAYERS OF ASTM D226
TYPE iI OR ASTM D4869 TYPE III
OR TYPE IV UNDERLAYMENT.
Note: WALL FENESTRATION FLASHING PER FSGR 703A -
Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to
prevent entry Of water into the wall cavity or penetration of water to the building
structural framing components. Self -adhered membranes used as flashing shall comply with
AAMA 711. All exterior fenestration products shall be sealed at the juncture with the
building wall with a sealant complying with AAMA 500 or ASTM C920 Class 25 Grade NS
or greater for proper joint expansion and contraction, ASTM G1281, AAMA 812, or other
approved standard as appropriate for the type Of sealant. Fluid -applied membranes
used as flashing in exterior walls shall comply with AAMA -114. The flashing shall extend to
the surface Of the exterior wall finish.
2194 HWY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325 J
SLJSDIV. 8e LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT#
04321.200 025R1
DA0DEL:
4EAB
"1672-ARIA"
GARAGE SWING:
RIGHT
PAGE:
DETAILS
160 MPH EP. C
ARCHITECT'
STATE OF FLORIDA
MAR 19" 2021
MICHAEL C. ANDERSON
AR NO 17305
FPRINT DATE: 03 17 21
SCALE: 1 /4"=1' — 0"
sxEET
0
TOP:
2X6 P.T. • CENTER OF DOOR HEADER SECURED
W/ (1) 1/2' X e' J-BOLT
W/ 4' MIN. EMBEDMENT
W/ 2' X 2' X 1/8' WASHER 4 NUT
OR
W/ (2) 1/2' X B' ANCHOR BOLTS
II/ 4' MIN. EMBEDMENT
2' X 1/0, WASHER 4 NUT
r--- L L - ---� , V� ----j j j —
LE
E
n
Ix4 P.T. OR 5/4'X4' MIN.
SECURE THRU FRAME 4
EXTEND 1-1/4' INTO
BLOCK W/ 3/16'
TAPCONS
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1-1/4'
WITHIN 8' OF EACH END
4 18' O.C. MAX SPACING
�L -j
BEGUN Tx4 ONlam
FLAT TO BLK -
W/ MASONRY
NAILS. - -
SIDES: -.T -
2X6 GARAGE DOOR BUCK SECURED
W/ (5) 1/2' X 8' J-BOLT OR ANCHOR E - L_
BOLTS, W/ 4' MIN. EMBEDMENT, W/ 2'
X 2' X 1/9, WASHER 4 NUT. (1) WITHIN
8' OF TOP, (1) WITHIN 8' OF THE BTM, -
(3) EVENLY SPACED.
7
NOTES:
ALL ANCHORS SHALL BE IN ACCORDANCE TO
MANUFACTURER'S INSTALLATION INSTRUCTIONS WHERE
SUCH INSTRUCTIONS ARE MORE STRINGENT
GARAGE DOOR
1 BUCK ATTACHMENT
' D SCALE, V -1'-m'
8' CMU
1/2' DRYWALL
1'X4'
P.T. NAILER
DOOR CASING
DOOR JAMB OR WINDOW
ATTACH TO 2X PER
MANUFACTURES DETAILS.
NOTE: SHIM AS NEEDED TO PLUMB
JAMB (DO NOT EXCEED 1/47
DOOR JAMB TO BLOCK +3/4" OR +5/4"
/-.1WINDOW TO BLOCK +3/4" OR +5 4"
n xis
2X4:
SECURE TO BLOCK W/
3/16' TAPCONS (MIN -
SHANK SIZE A45 MIN.
HEAD SIZE 300
MIN. EMBEDMENT 1 1/46)
WITHIN 8' OF EACH
END 4 18' O.C. MAX
SPACING.
2X6: CEM
SECURE TO BLOCK
W/(2) 3AW TAPCONS
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 1/49
WITHIN 8' OF EACH END
4 IS'O.C. MAX SPACING.
2XB: CEMI
SECURE TO BLOCK
W/(2) 3/16' TAPCONS
(MIN. SHANK SIZE A45
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 1/49
WITHIN V OF EACH END
4 18' O.C. MAX
SPACING.
LA 8' CMU
1/2' DRYWALL
❑ I'X4'
P.T. NAILER
DOOR CASING
DOOR JAMB OR WINDOW
ATTACH TO 2X PER
MANUFACTURES DETAILS.
NOTE: SHIM AS NEEDED TO PLUMB
JAMB (DO NOT EXCEED 1/49
DOOR JAMB TO BLOCK +1 1/2"
B)WINDOW TO BLOCK +1 1/2"
2X4:
SECURE TO BLOCK W/
3/16' TAPCONS (MIN.
SHANK SIZE J45 MIN.
HEAD SIZE 300
MIN. EMBEDMENT 1 1/4')
WITHIN 8' OF EACH
END 4 18' O.G. MAX
SPACING.
2X(P: CEM
SECURE TO BLOCK
WK2) 3/16' TAPCONS
(MIK SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 1/4')
WITHIN W OF EACH END
4 10' O.C. MAX SPACING.
2X6: CEO
SECURE TO BLOCK
W/(2) 3/16' TAPCONS
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 1/4')
WITHIN W OF EACH END
4 18' O.C. MAX
SPACING.
8' CMU
❑
1/2' DRYWALL
1'X4'
P.T. NAILER
l/16' O,S.B. X 4' MIN.
DOOR CASING
DOOR JAMB OR WINDOW
ATTACH TO 2X PER
MANUFACTURES DETAILS.
NOTE: SHIM AS NEEDED TO PLUMB
JAMB (DO NOT EXCEED 1/49
DOOR JAMB TO BLOCK +1 15/16"
nWINDOW TO BLOCK +1 15/16"
2X4:
SECURE TO BLOCK W/
3/16' TAPCONS (MIN.
SHANK SIZE .145 MIN.
HEAD SIZE 300
MIN. EMBEDMENT 1 1/49
WITHIN 8' OF EACH
END 4 V O.G. MAX
SPACING.
2X6: CEM
SECURE TO BLOCK
W/(2) 3AW TAPCONS
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 1/49
WITHIN W OF EACH END
4 18' O.G. MAX SPACING-
2X8:
SECURE TO BLOCK
W/(2) 3/16' TAPCONS
(MIN SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 1/4')
WITHIN 8' OF EACH END
4 18' O.G. MAX
SPACING.
NOTE: STRUCTURAL 2X MUST BE
ON OUTSIDE 4 SECURED
THROUGH NON-STRUCTURAL
3/16' TAPCON MIN. 1-1/4'
EMBEDMENT INTO BLOCK
8' CMU
1/2' DRYWALL
1'X4'
❑
P.T. NAILER
a
DOOR CASING
DOOR JAMB OR WINDOW
ATTACH TO 2X PER
MANUFACTURES DETAILS.
NOTE: SHIM AS NEEDED TO PLUMB
JAMB (DO NOT EXCEED 1/4')
DOOR JAMB TO BLOCK +2 1/4"
D WINDOW TO BLOCK +2 1/4"
2X4: ®
2X4:
SECURE TO BLOCK
SECURE TO BLOCK W/
W/3/16' TAPCONS (MIN.
1/4' TAPCONS (MIN.
SHANK SIZE .145 1`MN.
SHANK SIZE .145 MIN.
HEAD SIZE 300 ,
HEAD SIZE 300
MIN. EMBEDMENT 11/4')
MIN, EMBEDMENT 1 1/47
WITHIN 8' OF EACH
WITHIN S' OF EACH
END 4 18' O.C. MAX
END 4 18' O.C. MAX
SPACING.
SPACING.
2X6: ®
2X6: CEM
SECURE TO 13LOCK
SECURE TO BLOCK
W/(2) 3/16' TAPCONS
W/(2) 1/4' TAPCONS (MIN.
(MIN. SHANK SIZE .145
SHANK SIZE -145 MIN.
MIN. HEAD SIZE 300
HEAD SIZE 300 MIN.
MIN. EMBEDMENT 1 1/4')
EMBEDMENT 11/40)
WITHIN W OF EACH END
B' CMU
WITHIN 8' OF EACH END
4 18' O.G. MAX SPACING.
4 18' O.C. MAX SPACING.
1/2' DRYWALL
2X8: ®
2X8: INM
SECURE TO BLOCK
I'X4'
SECURE TO BLOCK
W/(2) 3/16' TAPCONS
P.T. NAILER
W/(2) 114' TAPCONS
(MIN. SHANK SIZE .145
DOOR CASING
(MIN SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 1/49
MIN. EMBEDMENT 1 1/4')
WITHIN W OF EACH END
WITHIN W OF EACH END
4 IS' O.C. MAX
4 10' O.G. MAX
SPACING.
DOOR JAMB OR WINDOW
SPACING.
ATTACH TO 2X PER
MANUFACTURES DETAILS.
NOTE. SHIM AS NEEDED TO PLUMB
JAMB (DO NOT EXCEED 1/4-)
DOOR JAMB TO BLOCK +3"
„
E xn
2X4: CM
SECURE TO BLOCK W/
3/16' TAPCONS (MIN.
SHANK SIZE .145 MIN.
HEAD SIZE 300
MIN. EMBEDMENT 1 1/49
WITHIN 8' OF EACH
END 4 18' O.C. MAX
SPACING
NOTE: STRUCTURAL 2X MUST BE
OUTSIDE 4 SECURED
2X6. CEO
THROUGH
THROUGH NON-STRUCTURAL
SECURE TO BLOCK
SEC
SEC
3/16' TAPCON MIN. 1-1/4'
TAPCONS
EMBEDMENT INTO BLOCK
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 1/4')
8' CMU
WITHIN 8' OF EACH END
4 18' O.C- MAX SPACING.
1/2' DRYWALL
2X8: ®
I'X4'
SECURE TO BLOCK
P.T. NAILER
WI(2) 3/16' TAPCONS
DOOR CASING
(MIN. SHANK SIZE .145
MIN. HEAD SIZE 300
MIN. EMBEDMENT 1 1/4')
2ND 2X SECURE TO STRUCTURAL
WITHIN 8' OF EACH END
MEMBER WK2)12d WITHIN 8'
4 18' O.C. MAX
OF EACH END 4 6' TO 8' O.C. MAX
SPACING.
DOOR JAMB OR WINDOW
ATTACH TO 2X PER
MANUFACTURES DETAILS.
NOTE: SHIM AS NEEDED TO
PLUMB
JAMB (DO NOT EXCEED 1/4')
DOOR
JAMB TO BLOCK +3"
F
x
8' CMU
❑ 1/2' DRYWALL
I'X4'
P.T. NAILER
1/16' O.S.B. X 4' MIN.
DOOR CASING
DOOR JAMB OR WINDOW
ATTACH TO 2X PER
MANUFACTURES DETAILS.
NOTE: SHIM AS NEEDED TO PLUMB
JAMB (DO NOT EXCEED 1/49
DOOR JAMB TO BLOCK +3 7/16"
WINDOW TO BLOCK +3 7/16"
2X4: CEO
SECURE TO BLOCK W/
1/4' TAPCONS (MIN.
SHANK SIZE J45 MIN.
HEAD SIZE 300
MIN. EMBEDMENT 1 1/4')
WITHIN 8' OF EACH
END 4 18' O.G. MAX
SPACING.
2X6: CEM
SECURE TO BLOCK
W/(2) 114' TAPCONS (MIN.
SHANK SIZE .145 MIN.
HEAD SIZE 300 MIN.
EMBEDMENT 1 1/49
WITHIN 8' OF EACH END
4 IS' O.G. MAX SPACING.
2X8: CEM
SECURE TO BLOCK
W/(2) 1/4' TAPCONS
(MIN. SHANK SIZE .145
MIN_ HEAD SIZE 300
MII%L EMBEDMENT 1 1/4')
WITHIN 8' OF EACH END
4 18' O.C. MAX
SPACING_
NOTE: STRUCTURAL 2X MUST BE
ON OUTSIDE 4 SECURED
THROUGH NON-STRUCTURAL
3AW TAPCON MIN. 1-1/4'
EMBEDMENT INTO BLOCK
e' CMU
1/2' DRYWALL
❑ ID
P.T..T.
NAILER
I' P-T. X 4' MIN.
DOOR CASINGS
DOOR JAMB OR WINDOW
ATTACH TO 2X PER
MANUFACTURES DETAILS.
NOTE: SHIM AS NEEDED TO PLUMB
JAMB (DO NOT EXCEED 1/4')
DOOR JAMB TO BLOCK +3 3/4"
H WINDOW TO BLOCK +3 3/4"
Reviewed fo: code
Compliance
Universal Eng,neenng
91
Sciences
CMU
DRYWALL
IX FURRING
X>::::.;::.:
.............
w
RIP 2XIO TO
DOOR
8-1/81W
FRAMING
HOLD FLUSH TO
INTERIOR FACE
OF DRYWALL
ENTRY
DOOR BUCK
QUIREMENTS
K k
2194 HWY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325 J
0
w
0
x
SUSDIV. 8e LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT#
04321.200 025R1
MODEL:
4EAB
"1672-ARIA"
aARAGE SWING:
RIGHT
PAGE:
DETAILS
160 MPH EXP. C
ARCHffECT
TOFTAEFLODA
MAR 19 2021
MICHAEL C. ANDERSON
AR NO T7305
DATE 03/17/21
SCALE: 1/4"=1' — 0"
SHEET
D2
NOTE:
IF ZIP SHEATHINGS SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
PREFORMED CONTROL JOINT -
FLANGE OF CONTROL JOINTS TO
BE WIRED TIED TO LATH a 9'
O.C. MAX (VERT-). NOTE: DO
NOT FASTEN CONTROL JOINT TO
WALL EVEN IF STUD EXISTS
BEYOND EXCEPT STAPLES W/
fib' LEG MAY BE USED TO TEMP.
SECURE CONTROL JOINT
DURING INSTALLATION \
FASTENERS TO BE SPACED
• 11' O-C. MAX VERTICALLY
a' THICK, 3 COAT CEMENT
PLASTER
WRB LAYER 02, FORTIF15ER
BUILDING PAPER
APPROVED METAL LATH
FASTENED 61' (VERT.) O.G. MAX
AT SUPPORTS
WRB LAYER 01,
STUCCO WRAP
WOOD SHEATHING
OR 1/16' ZIP SHEATHING
SYSTEM NNSTALLED PER
LATH SHALL NOT
BE CONTINUOUS 6 To a
MIN.
6 IN a
nIN.
THROUGH CONTROL
JOINTS BUT SHALL
BE STOPPED AND
TIED AT EACH SIDE-
PROVIDE 2X4 BLOCKING
PER ASTM C1063 \
PLACED FLAT MAX- W TO 8'
FROM JOINT
O NT
\
FALLS ONEN
CONTROLL.
NOTE: \
1. FASTENERS FOR LATH TO BE NAILS OR
/ STRUCTURAL STUD
STAPLES IN COMPLIANCE W/ ASTM CI063
2. WIRE TIES TO BE (NO. 18) 0.04T5' WIRE /
3. BLOCKING SHOWN MAY BE IN ADDITION/ \
TO WALL STUDS REQUIRED PER PLAN
O"M" TYPE CONTROL JOINT
O1. FOLD INWARD • IcT. A
OI. FOLD INWARD • F'T. A
2. CREASE • FT. B
FO
NOTE:
APPROVED BUILDING WRAP
SHALL BE LAPPED A MINIMUM OF
6' • VERTICAL LAPS (ROLL
ENDS) E 6' • HORIZONTAL LAPS.
ALL SEAMS NEED TO BE TAPED
WITH FORTIBER SHEATHING TAPE
/ I" MIN_ LAP ® METAL LATH
1 —r
6" MIN PAPER LAP BELOW ONLY /
WRB LAYER 02, FORTIFIBER
BUILDING PAPER
2 APER LAP
SCALE: 1 1/2' • I'-0'
(AKICKOUT
DETAIL
LATH VERTICAL LAP TO BE I'
I
METAL LATH
/ WRB LAYER 01,
STUCCO WRAP
M N LATH
A-, 4 OVER
ALL LAP
VERTICAL LATH
& PAPER DETAIL
NOTE:
IF ZIP SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
WOOD STUD:
SHEATHING -
NOTE•
SIDE LAPS OF METAL
OR Tiliv ZIP SHEATHING SYSTEM
PLASTER BASES SHALL
(INSTALLED PER MANUF. SPECS.)
BE SECURED TO
BUILDING —
FRAMING MEMBERS.
PAPER
THEY SHALL BE TIED
BETWEEN SUPPORTS
WITH 0.0415-NL (I21-MM)
STUCCO
WIRE AT INTERVALS NOT
MORE THAN 9' (229-MM).
AS PER ASTM C1063.
NOTE:
J' THICK, 3 COAT CEMENT
PLASTER
METAL LATH
WRB LAYER 02, FORTINEER
BUILDING PAPER
WRB LAYER 01,
STUCCO WRAP
WOOD SHEATHING
OR I/16' ZIP SHEATHING
SYSTEM (INSTALLED PER
MANUF. SPECS.)
6MIN.
LAP
LAP a LATH
LAP ® PAPER
FOR REPAIR OF TEARS HORIZONTAL LATH
IN WRB LAYERS, TEARS
MAY BE PATCHED & PAPER DETAIL
W/HOUSE WRAP TAPE
PER MANUF. SPEC. OR
PEEL 4 STICK
7/16' ZIP SHEATHINGS
® SYSTEM(INSTALLEDPER
WOOD SH �THIM5
fR
OR CMU
O I. FOLD INILLARD • ( Q.) 1. FOLD I E o P • Pr. A L1RB LAYER 01,
PT. A �/
7. CREASE • PT. B
'' CREASE • Fr' ® 3. clrtEaSE • Pr. c STUCCO WRAP (FRAME ONLY)
3. CREASE • PT- C
4. FOLD PT. C OVER Ft.
B TILL PT. C TOUCHES
BOTTOM FLANGE ® I•I` 8' THICK, 3 COAT CEMENT
® f ' PLASTER (FRAME), 1/2" 2 COAT
I� CEMENT PLASTER (CMU)
�" ,la METAL LATH (FRAME ONLY)
®
l LAP UJRB E TAPE OVER ®FOLD ® I; ROOF/UALL SCREED
SHINGLE ROOFING —
DRIP EDGE. OVERLAP 3'.
E,cTENp 1/2' BELOW
SHEATHING, MECHANICALLY
FASTEN 4' D.C. MAX
FLANGE L WATER TIGHT
SEAL FOLD, 22
MM CUT.
THICK 3 COAT CEMENT
PLASTER (FRAM), 1/2' 2 COAT
CEMENT PLASTER (CM)
WRB LAYER 02, FORTIFIBER
BUILDING PAPER(FRAME ONLY)
WRB LAYER "I,
STUCCO WRAP mvAm ONLY)
LAP LAYERS OF BUILDING WRAP
OVER NAILING FLANGE, STOP
UM AFFIROX I .W ABOVE
SHINGLES a-PLA E ONLY/
FRAME OR CMU
EXTERIOR
IXY1FArldl I RP�FFr]
5x5 WALL FLASHING
o
j B KTOC-OUT FLASHING (SEE
DETAIL)
FASCIA WRAP
e,
WATER TIGHT SEAL (BEND OR
SOLDER DO NOT [LT)
z_
"'III
„ L„
5"X5" "L" TYPE CONTINUOUS
CSALV. METAL FLASHING
(NAIL TO ROOF DECK, NOT
WALL SHEATHINGS)
CAP SHINGLE - DO NOT NAIL,
INSTALL WITH ROOF CEMENT
ROOF PER ELEVATIONS
FLASHING
4'x4' SELF -ADHERING MEMBRANE
FLASHING (COMPATIBLE W/ HOUSE
WRAP MATERIAL) OVER
APPROVED HOUSE WRAP.
FLASHING TO EXTEND ONTO PIPE
P OR LESS PIPE
PENETRATION
CUT AND OVERLAP ONE SIDE OF
SELF -ADHERING MEMBRANE
FLASHING
STEP "1
INSTALL FASTENERS (CLIPS,
STRAPS, STAPLES) AS
REQUIRED TO SECURE
PIPE/ WIRE TO FRAMING
SECTION
NOTE:
IF ZIP SHEATHINGS SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
NET
6>
6'x6' SELF -ADHERING MEMBRANE
FLASHING (COMPATIBLE W/ HOUSE
WRAP MATERIAL) OVER 4'x4'
SELF -ADHERING MEMBRANE
FLASHING OVER APPROVED
HOUSE WRAP.
FLASHING TO EXTEND ONTO PIPE
CUT AND OVERLAP ONE SIDE OF
. TE10 02 SEALFr-- D ERING MEMBRANE
FLING
WRB LAYER •I,
STUCCO WRAP
WRB LAYER'2, FORTIFIBER
BUILDING PAPER
METAL LATH
/----_.--6'xb' SELF -ADHERING MEMBRANE
FLASHING OVER 4'x4'
SELF -ADHERING MEMBRANE
FLASHING OVER APPROVED
HOUSE WRAP.
FLASHING TO EXTEND ONTO PIPE
4'x4' SELF -ADHERING MEMBRANE
FLASHING OVER APPROVED
HOUSE WRAP.
FLASHING TO EXTEND ONTO PIPE
%' CONT. BEAD OF SEALANT
— INSTALL APPROVED HOUSEWRAP AIR
INFILTRATION BARRIER OVER
SHEATHING
ELASTOMERIC COATING OVER STUCCO/
G.V. FINISH (SEE TYP WALL SECTION)
PER SECTION R703.7
Exterior lathing and plastering
Exterior use of portland cernent plaster
shall comply with the application
requirements of ASTM C 926-18b.
Installation of exterior lathing and framing
shall comply with ASTM C 1063-19a,
or ASTM 1787.
Reviewed for Code
Compliance
Universal Engineering
ED Sciences
TION DETAIL (fiRA„C )
DRAINAGE RLANE (WRB
L,4*rER 1*1, 5TUCCO WR)4P)
WRE3 LArER #2 (FORTIF15E R — — — — — —
BUILD INCH FAFER)
1 fiETAL L)4T14 X X X X
STUCCO
WOOD OR -1/1(0 II ZI1= WALL --
eHE)4T1-lIN --
5ELF-)4D14ESIVE FL45HINC — —
NOTE:
1 IETAL L)4T+ 4: L)4T14 TO BE PER SECTION
Ri03.�.1 /)4ST1"f C-8��1-1 a, 1"IIN. 2.5 L85.
PER 5Q- NrA) D (UTILIT)" OR NOti ANAL
LAT�4 DOES NOT t-IEET SIFECIFICATION5)
2194 HWY A1A. SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www, a b d es i g ng rou p. com
� AA #: 0003325
SUBDIV. 8e LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT#
04321.200 025R1
WODEL:
4EAB
"1672-ARIA"
GARAGE SWING:
RIGHT
PAGE:
WALL
ASSEMBLY
DETAILS
160 MPH EXP. C
ARCHITECT
STATE OF FLORIDA
MAR 1 9 2021
MICHAEL C. ANDERSON
AR NO 17305
PRINT / =?1
DATE:'. 0317/
SCALE: 1/4" =1'= 0"
�:� AAI
WAI
a
a
NOTE:
IF ZIP SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
BACKER ROD
BACKER ROD
X
_ J
I!Xi
'l X
INSTALL 6' SELF -ADHERING
MEMBRANE FLASHING OVER
TOP, SIDE(S) AND BOTTOM
FLANGES OF NON -MOVABLE
FRAME OF THE EXHAUST.
SEQUENCE OF FLASHING TO BE:
1. BOTTOM, 2. SIDES. 3. TOP
VENT CAP IS TO BE SET IN BED
OF SEALANT AT TOP AND
SIDES ONLY. SEALANT IS TO BE
TOOLED SO AS TO DEFLECT
WATER AWAY FROM JOINTS.
E-Z BEAD ALL AROUND
VENT -APPLY SEALANT ALL
JOINTS AND INTERSECTIONS
APPLY SEALANT AT PERIMETER OF
NON -MOVABLE FRAME AND STUCCO
ON ALL SIDES, Y4' CAULKING A JOINT
ALL AROUND
Exterior lathing and plastering
Exterior use of portland cement plaster
shall comply with the application
requirements of ASTM C 926-18b.
Installation of exterior lathing and framing
shall comply with ASTM C 1063 19a,
or ASTM 1787.
STUCCO
FINISH
6" SELF ADHESIVE
OVER TOP d SIDES
FLASHING
UNIT
PREMANUR DRYER
VENT CAP (SET IN
CONT- SEALANT)
SEALANT a
TOP E SIDES
ZYER VENT ( BLOCK
WRB LAYER "I, 1 XI
STUCCO WRAP i HOODED VENT BUILDING PAPER
X OVER FLASH
E x` THICK, 3 COAT CEMENT
PLASTER -�
METAL LATH
WRB LAYER 02, FORTIFIBEIR PIPE THROUGH
BUILDING PAPER WALL
WOOD SHEATHING
DRYER VENT ( FRAME)
6" SELF ADHESIVE
FLASHING (INSTALL
PER MANUF. SPECS)
BUILDING PAPER
UNDER 'QUICK FLASH'
LEGEND
DRAINAGE PLANE (WR5
LATER *1, STUCCO WRAP)
WR5 LAYER *2 (FORTIFI5ER — — — — —
5UILDING PAPER)
METAL LATH x—x—x—x
STUCCO J
WOOD OR 1/16" ZIP WALL -1
SHEATHING
SELF-ADHESIVE FLASHING —
NOTE:
METAL LATH: LATH TO 5E PER SECTION
R-103.7.1 / ASTM C-04-1-14a, MIN. 2.5 LBS.
PER SCE. YARD (UTILITY OR NOMINAL
LATH DOES NOT MEET 5 ECIFICATIONS)
/ NOTE:
IF ZIP SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
A VENT PENETRATION
SCALE: N.T.S.
ELEC. METEF
VERIFY LO
IAK=H ICJ 14<>=LW=I Y=
STUCCO SCRATCH COAT
# 1 GOAT OF PAINT W/5AGK-
ROLL PRIOR TO
ELEC. METER INSTALLATION
C. METER FIELD
:IFY LOCATION
.-., , 'LY STUCCO SCRATCH COAT
AND ONE (1) LAYER OF PAINT
PRIOR TO INSTALLING ELEC.
METER
CAVITY TO 5E FILLED
WITH RIGID POLYMERIC
I5OCYANO7i E-POLY5LEND FOAM
• ^t 1 " SIMILAR)
APPLY A SILICON
BASE SEALANT AT POINT
THAT ELEC. WIRE PENETRATES
I I �� * I r H v i .wvv0 SCRATCH
COAT LARGER THAN THE ELEC.
METER CAN OR METER CAN
COM50 OR METER CAN AND
D ISCONNEGT
O ELECTRICAL CONDUIT
PENETRATION
CUT OPENING IN
APPROVED HOUSEWRAP
FOR BOX INSTALLATION
WRB LAYER *i,
STUCCO WRAP
WOOD SHEATHING
APPROVED
HOUSEWRAP
BELOW
CUT SUCH T
NO MEMBR
ENTERS E
APPLY TO F
EI
APPLY E-Z BEAD
OVER rc0 MIN
GRADE 'D'
FELT -PROVIDE
SEALANT AT ALL
JOINTS AND
INTERSECTIONS
STF '*1
5T f *13
p •0.0.0 p
.O 1.
,. o
.. o.
.0
00
.0 0.
o .o.o.o 0
5T E F
WOOD SHEATHING
*
WRB LAYER *I,
STUCCO WRAP
WRB LAYER 02, FORTIFIBER
BUILDING PAPER
METAL LATH
WOOD
CONSTRUCTION
II
1/0, TEXTURED
FINISH +WOOD
FASTEN TO WOOD STRUCTURAL
MEMBER o -I' O.G. MAX
a' CMU
Ye' TO Jim MID -WALL
C'
WEEP 5CIRSED
_
=IL
6' WIDE STRIP SELF
ADHESIVE FLASHING, CLEAN
MASONRY BEFORE APPLYING
TEXTUWD
FINISH a MASONRY
B HORIZONTAL
WEEP SCREED
(FRAME
TO BLOCK)
NOTE:
IF ZIP SHEATHING SYSTEM IS
INSTALLED, PLEASE SEE
MANUFACTURERS
INSTALLATION PROCEDURES
a
WRB LAYER *1,
STUCCO WRAP
CUT 'X' INTO \
SELF -ADHERING / \
MEMBRANE FLASHING
APPLY SIADHERING
MEMBRANE FLASHING
OVER BOX AND OVER
APPROVED LI
LAYER *1
ISTE1 1*2
APPLY 60 MIN
GRADE 'D' FELT
OVER
SELF -ADHERING - -
FLASHING OVER
APROVED
HOUSEWRAP
Reviewed for Code
Compliance
Universal Engineering
ED Sciences
WRB LAYER *I,
STUCCO WRAP
SELF -ADHERING
MEMBRANE FLASHING
LI LAYER *2, FORTIFIBER
BUILDING PAPER
STF #
ELASTOMERIC
COATING OVER
STUCCO/ C.V- FINISH
(SEE TYPICAL WALL
SECTION)
METAL LATH
5T E F #(a
CTRICAL RECEPTACLE
2194 HWY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
1111111
SUBDIV. 8e LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT
04321.200 025R1
MODEL
4EAB
"1672-ARIA"
GARAGE SWING:
RIGHT
PAGE:
WALL
ASSEMBLY
DETAILS
160 M°:''H EXP' C
ARCHITECTf
STATE OF FLORIDA
MAR 19 2021
MICHAEL C. ANDERSON
AR NO 17305
AT DE: 03/17/21
SCALE: 1/4"=1r-0"
SHEET
1
DRAINAGE fLANE (WRE�
LATER #1, STUCCO WRAP)
WRB LATER #2 (FORTIFIBER — — — — —
SUILDING PAPER)
METAL LATH x x x x
STUCCO
WOOD OR —1/1(0" ZIP WALL
SHEATHING
SELF—ADHESIVE FLASHING
2 1/211
CORNER BEAD
T (FA5TENER 4 SPACING 0 1" C.C.)
.e
1 A 1:�1CORNER BEAD
1 1 L /
GMU
1/2' TNICK, 2 COAT CEMENT
PLASTER APPLIED
DIRECTLY TO MASONRY
(ii) BLOCK
Reviewed for Code
Compliance
bm Universal Engineering
Sciences
2194 HWY A1A. SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325 J
SUBDIV. 8e LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJEr T*
04321.';00 02t`R1
MODEL:
4EAB
"1672—ARIA"
GARAGE SWING:
RIGHT
PAGE:
WALL
ASSEMBLY
DETAILS
160 MPH EXP. C
ARCHffECT
STATE OF FLORIDA
- MAR 19 2021
UCHAEL C. ANDERSbN
AR NO T7305
DATE: 03/17/21
SCALE: 1/4"=1'-0"
SHEET
it
1
rra,
,n
®■
]LEGEND
DRAINAGE PLANE (WR5
LAYER 01, STUCCO WRAP)
WRB LAYER *12 (FORTF15ER - - - -
BUILDING PAPER)
METAL LATH x-x-x-x
STUCCO
WOOD OR 1/16" ZIP WALL
SHEATHING
SELF-ADHESIVE FLASHING
WOOD CONSTRUCTION
BEYOND
WOOD SHEATHING
WEATHER RESISTIVE
BARRIER M
i
WEATHER RESISTIVE
//
\
"2
g5ARRIER
AP SIDING6'
SELF -ADHERING
FLASHING
WSELF-ADHERING-
FLASHING
6
WEATHER RESISTIVE
BARRIER 01
R"ev
STARTER STRIP
WEATHER RESISTIVE
\
BARRIER "2
DO NOT CAULK OR
�
6'SELF-ADHERING
SEAL OPENING
I
FLASHING
GALV'D METAL
METAL
�'
I
W FLASHING
W rLA
Z' FLASHING
DO
NOT CAULK OR
1 Y1 X 6' SIMULATED)
_
-
SEAL
OPENING
WOOD TRIM MEMBER
STUCCO CASINGBEAD
\
I Ya' X 6' SIMULATED
WOOD TRIM MEM5FR
IV
\ ,
SEAL GAP W/CAULKING
-_
KSTUCCO
OR APPROVED SEALANT
CASING
BEAD
SIDING
TO STUCCO
C)
BLOCK TO FRAME
��
TRANSITION
11
J H
WOOD CONSTRUCTION
BEYOND
WOOD SHEATHING —
WEATHER RESISTIVE
BARRIER 01
WEATHER RESISTIVE
i
/t_'9\
\
BARRIER +2X?
T Ya'
AL OSIDING/
Itllo REPEAL R
6' SELF -ADHERING
50ARD 4 5ATTEN
FLASHING
WEATHER RESISTIVE
FLASHINGWSELF-ADWERING
BARRIER *1
STARTER STRIP
WEATHER RESISTIVE
\
BARRIER M2
DO NOT CAULK OR
WSELF-ADHERING
SEAL OPENING
I
FLASHING
GALV'D METAL
GALV'D METAL 'y 'Z' FLASHING
Z' FLASHING
- DO NOT CAULK OR
HARDIE TRIM PER SEAL OPENING
ELEVATION
STUCCO CASING \ \
BEAD
24
HARDIE TRIM PER
ELEVATION
\ SEAL GAP W/CAULKING
OR APPROVED SEALANT
KSTUCCO
CASING
BEAD
SIDING TO STUCCO
® BLOCK TO FRAME
TRANSITION
N' Reviewed to, code
Compliant eenna
a Universal En9
Silences
2194 HWY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
SUBDIV. & LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT#
04321.200 025R1
MODEL:
4EAB
"1672-ARIA"
GARAGE SWING:
RIGHT
PAGE:
WALL
ASSEMBLY
DETAILS
160 MPH EXP. C
ARCHITECT
STATE OF FLORIDA
MAR 19 2021
MICHAEL C. ANDERSON
AR NO 17305
PRINT 03 17 21
DATE: / /
SCALE: 1/4"=1'-0"
SHEET
lly'vvill
a
1
1
I
I
II
1
1
1\
- - 2x(o SUB -BAND
— W/1 "x4" NOTCH
- - END, WRAPPED IN
PEEL 8 STICK
DRIP EDGE
1/8" TEXTURED
FINISH 'a WOOD
1/2" TEXTURED
FINISH 'a CMU
METAL FASCIA
WRAP Yap FROM
STUCCO, 1" FRO
\ WOOD WALL
\
EXTERIOR WALL
(FRAME OR CMU
\\ NOTE: NOTCH FOR 2X6
\\ SUB BAND ONLY
\
\
\
\
( )ELEVATION-
r�
11
it
II
II
I 1
I 1
I 1
/ 1
� 1\
1
1
M 11
11
11
11
1
1
ml
METAL FASCIA WRAP
2X6 SUB HAND-- =
c�
COPL= AN B
—ROOF KICK OUT REMOVED
11 FOR CLARITY
-ROOF DECK (BEYOND)
DRIP EDGE, 1" OFF WALL
VNOT INTO STUCCO)
�— 11/8" TEXTURED FINISH Q
WOOD, 1/2" TEXTURED
FINISH 6 CMU
�,-!!�---2x6 SUB -BAND W/1"x4" NOTCH
END, WRAPPED IN PEEL 4 STICK
METAL FASCIA WRAP I' OFF
WOOD WALL. SUB BAND 2"
OFF WOOD WALL
1/8' TEXTURED
FINISH ® WOOD,
1/2' TEXTURED
FINISH o CMU
METAL LATH
WOOD SHEATHING
OR CMU
WRB LAYER 01,
STUCCO WRAP (FRAME ONLY)
WRB LAYER *2, FORTIF15ER
BUILDING PAPER
(FRAME ONLY)
ROOFING CEMENT
DRIP EDGE
METAL KICK OUT
NOTE:
IF ZIP SHEATHING
PLEASE SEE MAT
PROCEDURES
PRE-ENG'D TRUSS TO BE GUT
WALL LINE TO AVOID CONTACT
W/TEXTURED FINISH
2 "x4'x4' -m'
SCABBED TO TRUSS
W/126 NAILS ro"-8"
O.G. MAX.
2x SUB -SAND W/lY"x4"
NOTCH 'a END
METAL FASCIA WRAP
DRIP EDGE
EXTERIOR WALL
(FRAME OR CMU)
SUB BAND DETAIL Qi) WALL
SUB BAND DETAIL C) WALL
W /KICK -OUT
FRAME OR CMU
FELT PAPER
DRIP EDGE
(REFERENCE POINT
ONLY, FOR WALL OFF
BET OF COMPONENTS)
METAL FLASHING, WRAPPED
MIN. Ya." ABOVE BOTTOM OF
DRIP EDGE
2x SUB -BAND
W/11�"x4" NOTCH 'a
END, WRAPPED IN
PEEL 4 STICK
*ROOF CEMENT a
ROOF EDGE
OMITTED FOR
CLARITY
Reviewed for Code
Compliance
Universal 91 nceseenng scie
FRAME OR CMU
WALL KICK -OUT FLASHING
FELT PAPER
DRIP EDGE
(REFERENCE POINT
ONLY, FOR WALL OFF
SET OF COMPONENTS)
METAL FLASHING, WRAPPED
MIN.4" ABOVE BOTTOM OF
DRIP EDGE
2x SUB -BAND
W/IYHx4" NOTCH e
END, WRAPPED IN
PEEL 8 STICK
*ROOF CEMENT e
ROOF EDGE
OMITTED FOR
CLARITY
2194 HWY A1A. SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
SUBDIV. 8e LOT:
CREEKSIDE
PHASE 2.3_
LOT #25
-;:'ROJECT#
04321.200 025R1
IAODEL:
4EAB
"1672-ARIA"
GARAGE STIMG:
RIGHT
PAGE:
WALL
ASSEMBLY
DETAILS:
SUB -BAND
160 MPH EXP. C
ARCHITECT:
STATE OF FLORIDA
I MAR 192021
MICHAEL C. ANDERSON
AR NO 17305
PRINT 2117
DATE: 03 / /
SCALE: 1/4"=1'-0"
SHEET
WAIS
38'- 8„
12'-0„
26-8"
4"
10'-8'.
9,-6
13 -4„
3 -10„
EXTEND
SLAB
1
/2"
on o
E
FM-12X12
FM' 12X18
4" GONG.
00
1.1
T'
SLAB
00I
N
111
o
Xcli
LlJ LL
eo_�
I
*31/2"
IL Ow
I� n
LL
LL
F-24X24
1 3, 2„
6, q„
2,4°
I
J
0IN10
FM-12X18
1
1.1
I
GL
TOP OF
6
SLAB
1" PVC CHASE
00
FOR ELEC. @
x
ISLAND
LIL
I
u
1.1
co
x
xLIL
I I
I
'
II
III
III
II
II
I
19, 0„
II
� „
19' 0„
J
0
v
co
in
eo
\\ \
<
0•�
\\
I
V
\
\
\\
I
O
n
�� \\
EXTEND `.\
4" PVC
~
SLAB 1 1/2"
CHASE
TE-1—
— — — — —
\
*5 1/2" \ \\
4" CONC.
SLAB
I
a
5
\
\
op
8' oll
2' 8"
1 T 8" 1.1
2' 4,,
TOP OF
M
Iop
I
Iu
n
co
1
co
1.1
I
N
�I
�I
op
N
1
Ui
LLI
1.1
EXTEND
LL
O
FM-12X18
SLAB 1 1/2"
2
4
_
�
I
C
1.1
CONC.
Ioo
— �
x
a
SLAB
a
wl
31
2" Oa
XCO
cvl
6 35,
wI
L
IIE-1
LL
2
1
It
ao
FMC I2A18
1.1
7 1/2"
FMC 4
4
L —
FM_12X18
— —
1.1
J
12X18 1.1
FM-12X18
1. i
=
.
F M -12 X 12
—
— — —
— —
— —
^
o
❑
E
F
•
—
IN
8' 6"
2 6"
2' 0"
4'-4"
2'-0„
„
16'-0'
2' 8„
11,_0„
g'-q
19'-4"
38'-8"
FOUNDATION NOTES
. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR
OMPACTING REQUIREMENTS.
TOP OF FINISHED SLAB SHALL BE+-U-0".
COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED
THERWISE.
4. REFERENCE ELEVATION +40' SEE SURVEY PLOT FOR NAVD.
5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN
TIERMITES, TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS
ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER
ERVICES.
. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE:
ROVIDE 1/2" FELT PAPER AT THE JOINT.
. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL
DRAWINGS.
SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING.
WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE
INDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS
AND WITH THE MANUFACTURES SPECIFICATIONS.
10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT.
1 AJINDICATES #5 BAR, EIINDICATES #6 BAR,■INDICATES #7 BAR VERTICAL
REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE
HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 900
HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS.
2, SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 =
0", #6 =36"), AND REINFORCING SHALL BE CONTINUOUS.
13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL
REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE
OIL BEARING CAPACITY OF 2,000 PSF TRANSFER REINFORCING (TOP STEEL) HAS
BEEN DELETED UNLESS NOTED OTHERWISE.
14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS
OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE:
) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION
) EACH SIDE OF ALL OPENINGS D) ALL CORNERS
15 STRUCTURAL DESIGN IS IN ACCORDANCE WITH TMS 402/602-16, BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. CONSTRUCTION
HALL BE IN ACCORDANCE WITH TMS 402/602-16, USING: F'm'= 2,000 PSI, TYPE "M" OR"S"
MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN RUNNING BOND.
16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER a OF SLAB SUPPORTED
'-0" O/C MAX. SEE PLAN FOR WWM SIZE.
INSPECTOR NOTE:
1, STRUCTURE WAS DESIGNED BASED ON THE 2020 FLORIDA RESIDENTIAL BUILDING
ODE, RESIDENTIAL, 7th EDITION
i Reviewed for Code
Compliance
Universal Engineering
91 Sciences
SLAB SCHEDULE
SLAB
THICKNESS
REINF.
REMARKS
6x6 W1.4XW1.4OVER
GENERAL
3 1/2
6 MIL VAPOR
COMPACTED FILL
BARRIER
FOOTING SCHEDULE
(CORNER
PROVIDE
BARS, SAME SIZE QUANTITY AS BARS IN FOUNDATION, WITH 30" LEG EACH WAY.
MARK
WIDTH
LENGTH
THICKNESS
BOTTOM REINF.
TOP REINF.
T.O.F.
FM-12x
12"
CONTINUOUS
18"
(+)0' 0"
FMC-12x
8
12"
CONTINUOUS
181,
=#5's(2)
#5 IN CURB
VARIES
F-24R24
24"
24"
12
(-)0"-4"
12"
CONTINUOUS
12"FM-12x18..SEE
T112
PLAN
8"
(-)0'-0"
FOUNDATION PLAN
SCALE: 1/4" = 1 7
SECURE
STRAP To
AIC
SIMPS❑N WB
CONC, W/
UNIT
ROLL STRAP OR
(2)-3/16'X2'
EQUAL R EACH
TAP —CONS
CORNER OF
UNIT
CONC,
SECURE STRAP TO
SLAB
UNITS W/ (2) #Bx1
1/4 SHT MTL
SCREWS
A/C
CONNECTION
TO
PAD DETAIL
2194 HWY A1A, SUITE 30
INDIAN HARBOUR BEACH
FLORIDA 329:�7
PH: 321-802-3691
www.abdesigngroup.com
AA #: 0003325
<
7
I
k
J
ilr
i I
\ is
Z +,
BUBDIV. & LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT*
04321.200j025R1a
MODEL:
4EAB
"1672—ARIA"
GARAGE BRING:
RIGHT
PAGE:
FOUNDATION
PLAN
�160 MPH EXP `
ARCHITECT
STATE OF FLORIDA
MAR 19 2021
MICHAEL C. ANDERSON
AR NO 17305
PRINT
DATE: 03/17/21
SCALE: 1/4"=1' — 0"
SF1EET
S 1
4
Z
STEEL REINFORCING IN GROUTED
CELL SEE PLAN FOR SIZE AND
} _ SPACING REQUIREMENTS
F-
4 W
m
co J
0 - Z - 8" CMU WALL
I`
0
M a TOP
° SEE SLAB SCHEDULE
EXT. PORCH SLAB aL
4" CHAMFER (1-STORY)
W/1/2" ISOLATION 6" CHAMFER (2-STORY)
JOINT (WHERE a
APPLICABLE) z SEE SCHEDULE
FOR WxD, BAR SIZE
N AND BAR QUANTITY
Z_
STEEL REINFORCING IN GROUTED
d
CELL SEE PLAN FOR SIZE AND
>
(
SPACING REQUIREMENTS
F-
LU
m(
w
J
V a
�
O
8" CMU WALL
co
_ Z
01-01,
iLA6
i
1L3��1 iF�.,l Y
BAR SIZE
48 BAR DIA.
#3
18"
#4
24"
#5
30"
#6
36"
#7
42"
1 EXTERIOR MONO -FOOTING
BOLLARD
LAP NP PLATE A M. OF 48"
AND N W/ 16d IN
COMMON
NAILS, 2- WS, 4 O/C BTM.
LAP TOOC R OVER STUD
2x4 OR 2x6 W\2UDS
WALL W/ SYPPLANS FOR SBTM. PLATE TPROVIDE DB
'IPE
SASE
GE TO
" X 2 1 /4"
VERIFY HEIGHT
OF WALL W/ PLAN
PROVIDE BLOCK G
REB . PLATE TO
LA / d MASONRY NAIL
1p TAGGERED.
IONAL METAL
NECTORS NOT
QUIRED WHEN NO
UPLIFT IS PRESENT.
SEE SLAB SCHEDULE
+- U'_U
TOP OF SLAB °
?1OR SfE SCHEDULE
FOR WxD, BAR SIZE
D BAR QUANTITY
(9 INNDATION OD WALL
SCALE:3/4"=V-0" (NO LIFT)
SEE SLAB SCHEDULE TOP
EXT. PORCH SLAB 4" CHAMFER (1-STORY)
W/ 1/2" ISOLATION 6"CHAMFER (2-STORY)
JOINT (WHERE • ' • SEE SCHEDULE
APPLICABLE) z_ ° FOR WxD, BAR SIZE
AND BAR QUANTITY
N
C2 XTF-RIOR MONO -FOOTING
GARAGE
A R A G E SCALE: 3/4"=1'-0"
w
01
W J
I
co
NEW REINF BAR
O a
SECURED W/2-PART
EPDXY. MIN. EMBED
J'q
8"; UNO
Q
jp
FOLLOW ALL MANF.
=
¢
SPECIFICATIONS FOR
a
I
USE AND
r
00
PREPARATION OF
C7
!"
HOLE.
Z
w
ilk
o
c+)
�O
QQ
,P
4" CHAMFER (1-STORY)
6 CHAMFER 2-STORY
ADDING BAR TO
MONOLITHIC FOUNDATION
SCALE. 3/4"=V-0"
STEEL REINFORCING IN GROUTED
CELL SEE PLAN FOR SIZE AND
SPACING REQUIREMENTS
Q
o:}
m w
00
C J L
¢a
O � 8" CMU W
o '
mz ,
I° to
SEE SLAB SCHEDULE
Z
Z —
"ISOLATED COLUMN PAD
CENTERED UNDER WALL AND
co POURED MONOLITHICALLY WITH
— — FOUNDATION AND SLAB
SEE SCH ULE
sv FOR WXD, BA SIZE
AND BAR QUAN TY
MBINED EXTERIO MONO-
OOTING AND COL. P
611m-.
30"
MIN. EACH WAY
- --- MONOLITHIC FOOTING
FM
CORNER BARS, SAME SIZE AS LARGER BAR i
IN FOUNDATION WITH 30' LEG EACH
WAY AT ALL CHANGES IN DIRECTIONS
SO THAT THE STEEL REINF. IS CONTINUOUS
f I� MATCH AMOUNT OF CONTINUOUS BARS
CONTINUOUS STEEL MONOLITHIC
FOOTING REINFORCEMENT SEE SCHEDULE
WHEN TRANSITIONS ARE MADE FROM FOUNDATIONS HAVING
DIFFERENT NUMBER OF CONTINUOUS BARS PROVIDE THE LEI ST
NUMBER OF BARS (ie. 2 TO 3, PROVIDE 2 BARS), UNO
MONOLITHIC FOUNDATION
CORNER BARS DETAIL
AP TOP PLATE A MIN. OF 48"
A NAIL W/ 16d COMMON
NAIL 2-ROWS, 4" O/C BTM.
LAP T CCUR OVER STUD
2x4 OR 2x6 \BEARING
WALL W/ SYP
No 2 STUDS SESPACING. SINGTO BE PT. PROPLATE
SIMPSON SPH4BTM AND TOP ANCHORS W/ 1
COMMON NAILS FILL ALL
HOLES, DO NOT USE 10d
x 3" 1*k
+- 0'-0"
TOP OF SLAB
SCALE: 3/4"=V-0"
/HIGHEIGHTW/PLANBLO INGPLATE TO SLAB Wl�GE ANCHOR W/ 2"T IN HIGH STRENG H" EMBED. MIN. @ 16�' OC
EE SLAB SCHEDULE
EQ. EQ. SEE SCH ULE
FOR WxD, BA IZE
AND BAR QUANT
INTERIOR CURB FOUNDATION WOOD Wp
SCALE:3/4"=V-0" (W/ UPLI
POURED LINTEL'CONT. (TYP.)
8" CMU FILLED CELL (TYP.)
2X WALL FRAMING
1/2" DIA. SIMPSON STB2BOLTS 5"
MINIMUM EMBEDMENT INTO
GROUTED CELL, 4" FROM ENDS AND
16" O.C. VERTICALLY MAX
INTERIOR FRAME BRG WALL TO
BLOCK WALL CONNECTION ,
SCALE. 3/4"=V-0"
RB FOR
.SONRY
ITS SET
ELEV:
RECESS AROUND GARAGE
DOOR OPENING
1_/
LAP TOP PLATE A MIN. OF
AND NAIL W/16d COMMON
NAILS. 2-ROWS, 4" O/C BTI
LAP TO OCCUR OVER STU
2x4 OR 2x6 WOOD BEARIN
WALL W/ SYP No 2 STUDS
PLANS FOR SPACING. SIN
BTM. PLATE TO BE PT.
PROVIDE DBL. TOP PLATE
O
+ 0'-0"
-
OF SLAB TOP
� � n
EQ. EQ. SEE SCHEDULE
FOR WxD, BAR SIZE
AND BAR QUANTITY
INTERIOR CURB FOUNDATION WOOD WALL
SCALE: 3/4"=l'-0"
VERIFY HEIGHT
OF WALL W/ PLAN
PROVIDE BLOCKING
SECURE BT. PLATE TO
SLAB W/10d MASONRY
NAIL 16" O/C STAGGERED.
ADDITIONAL METAL
CONNECTORS NOT
REQUIRED WHEN NO
UPLIFT IS PRESENT.
SEE SLAB SCHEDULE
SCALE: 3/4"=l'-0"
(NO UPLIFT)
2194 HWY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591-
www.abdesigngroull.com
AA #: 0003325
1a
jti9
a
I
.1
a
rcry
us
70MIV 8c LA:)T.
UREEKSIDE
PHASE 2
LOT #25 ._.
PROJECT#
04321.200 025R1
:AODET •
4EAB
"1672-ARIA"
GARAGE SWING:
RIGHT
PAGE:
i
DETAILS
160 MPH EXP. C
ARCHrrECT
STATE OF FLORIDA
MAR 19 2021
19 Pr �AEL C. ANDERMN
PRINT DATE: 03 17 21
1 SCAT : 1/4"=1'-0" 1
SHEET �
S1.IA
2194 HWY A1A, SUITE 301
ri
INDIAN HARBOUR BEACH,
K
FLORIDA 32937
PH: 3217802-3591
www.abdesigngroup.com
AA #: 0003325
�N
u
a
S
SX BDIV. ac LOT-7
CREEKSIDE
PHASE 2
LOT #25
FROJECT#
04321.200 025R1
MODEL:
4EAB
" 1672- ARIA"
GARAGE SWING:
RIGHT
PAGE:
DOWEL
PLAN
h 160 MPH EXP. Cam'
ARCHfTECT
STATE OF FLORIDA
MAR 19 2021
MICHAEL C. ANDERFO
mummm
PRINT 2117
DATE: 03 / /
SCALE: 1/4"= V — 0"
SHEET
sI
TIE VERTICAL REBAR
TO HORIZONTAL
REBAR W/ 10" HOOK
GROUTED BOND BEAM
VARIES PER ELEV.
Z d
a
N
r
J I
Q
p _-- CLEAN OUT REQUIRED
Q FOR INSPECTION
m
00
0'-0" FIN. FLR.
TIE VERTICAL REBAR
TO HORIZONTAL
REBAR W/ 10" HOOK
e �-
HORIZONTAUVERTICAL
REINFORCING
BAR SIZE
48 BAR DIA.
#3
18"
#4
24"
#5
30"
#6
36"
#7
42"
SCALE: 3/4"=l'-0" I
z
�
STEEL REINFORCING IN GROUTED
CELL SEE PLAN FOR SIZE AND
}
SPACING REQUIREMENTS
CC ~
1
mLU
0 J
O
Z
- 8" CMU WALL
_
�-
o
I f
j SEE SLAB SCHEDULE
EXT. PORCH SLAB 4" CHAMFER (1-STORY)
W/ 1/2" ISOLATION 6" CHAMFER (2-STORY)
JOINT (WHERE •
APPLICABLE) Nz MATCH STEEL
REINFORCEMENT
6" PVC CHASE iv PER SCHEDULE
THRU FOOTING -
SEE SCHEDULE
FOR WxD BAR SIZE
TOP OF
BAR SIZE
48 BAR DIA.
#3
18"
#4
24"
#5
30"
#6
36"
#7
42"
AND BAR QUANTITY PVC CHASE
4 THRU FOOTING
SCALE: 3/4"=1'-0"
REINFORCEMENT
PER SCHEDULE
NG
#5 BARS
CMU UNIT DIMENSIONS
ap ARE NOMINAL SIZES
• MASONRY SYMBOLS
SCALE:3/4"=1'-0"
Reviewed for Code
Compliance
al Universal Engineering
Sciences
2194 HWY A1A. SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
� AA #: 0003325 J
SUBMV. & LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT#
04321.200 025R1
MODEL:
4EAB
"1672-ARIA"
GARAGE SWING:
RIGHT
PAGE:
DETAILS
160 MPH EXP. C
ARCHrrECT-
STATE OF FLORIDA
MAR 19 2021
MICHAEL C. ANDER. ON
AR NO 17305
DATE 03/17/21
SCALE: 1 /4"=1' - 0"
SHEET
Ste2A
FRAMING NOTES:
1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE
CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9)1Od x 1 1/2" HDG NAILS.
CONCRETE TO WOOD FLOOR:
SIMPSON LTA2 W/ (8) 1 Od x 1 1/2" HDG NAILS, WOOD TO WOOD:
SIMPSON Hill 0A OR LGT2 W/ 1 Od x 1 1/2" HDG NAILS, FILL ALL HOLES.
2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER
SCHEDULE.
3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE
MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS,
4, ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS
ARE TO BE GALVANIZED.
5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE,
CONNECTERS ARE TO BE GALVANIZED.
6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE
CONCRETE LINTELS.
7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND
CLEAR SPAN OPENINGS,
8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4").
9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE
SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE
FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL'FINALTRUSS DESIGNERS
LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEERS REVIEW AND
APPROVAL.
10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES
SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED
FASTENER, ZF 72 PBS36, .177" ° x 2 7/8" LONG, WITH WASHER @ 16" O.C.
11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE, SAME ON EACH END
UNLESS OTHERWISE SHOWN DIFFERENT.
12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON
RATIONAL ANALYSIS.
13. ALL ELEVATIONS ARE REFERENCED FROM U-0", FINISH FLOOR. UNLESS
NOTED OTHERWISE
HEADER SCHEDULE
MARK
S
ZE 8r
REMARK
ES
RIPTION
(D
(
)'2X8
BEAM SCHEDULE
INDICATES OPENING BELOW / T.O.B. = TOP'OF BEAM / B.O.L. = BOTTOM OF LINTEL /T.O.A. = TOP OF ARCH/T.O.S =TOP
OK
SLAB
ABBREVIATIONS E.E. = EACH END, O/C = ON CENTER, F.E.S. = FROM EACH SUPPORT, T.O. = THROUGHOUT ,
MARK
DESCRIPTION
(psi)
SIZE ZE'
REINFORCEMENT
STIRRUPS
REMARKS
BTM.
TOP
MID
SIZE
SPACING
BB1
MASONRY
3000
8z8
—
(1)#5
—
N/A
—
GRO
TED
SOLID
SEE SHEET
S2.2A FOR
SAFE LOAD TABLES
;
-----------�r..�..-----------�----------------------8F16-1T/0M/0B 8F16-1T/0M/0B
8F16-1 T/OM/OB
r211
o♦
m2
o
2.
1�
♦
-
e
Jib
♦o
N
,°
I
ILL 0
ILL
♦
00
GT
8F16-1T/0M/0B
— ----- —
♦
J/
I
♦
I
I
1
%
♦♦
°
1`
♦♦
401141
♦♦
f
♦♦
##
1
♦o
1
i°
I
Y
�
� 1
1
I
1
It
1
1
1
Reviewed for Code
o
' Compliance
Universal Engineering
l
1
1 Sciences
l0
1
1
Ir
I
1
ILL
1
1
1
1
1
1
I
1
UNO, PROVIDE BB1 WHERE
1
1
ROOF TRUSSES BEAR, TOP
I
1
1
OF WALL EL. 8'-8", UNO.
1
1
I
I
1
1
I
1
1
I
1
1
1
1
�
I
01
1
0
♦♦
„
1
,4*
1
,I
8RF6- I
I
1
1 T/50
4/OB '*#�
1rT,
i
i
1
8F16-1T/0M/0B
8F8-
I 8F28-1T/0M-1B
1T1;0Mi0B
L----------------------------J
------
-----
2194 H WY A1A, SUITE 301
INDIAN HARBOUR $EACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroLip.com
AA #: 0003325
SXMDIV. & LOT 1
CREEKSIDE
PHASE 2
LOT #25
PROJECT
04321.200 025R1
MODEL:
4EAB
"1672-ARIA"
GARAGE SWING:
RIGHT
PAGE:
LIFT BEAM
PLNIN AND
NOTES
160 MPH EXP I
T•
=:T202I
STATE RIDA
1;I
MAR
MICHAEL C. ANDERSON
AR', NO 17305
PRINT 03 17 21
DATE:
LIFT BEAMPLAN SCALE::
SCALE: 1/4" = 1'-0"
SKEET
dy
ai
#5 CORNER BAR W/ 30" LAP FOR
COURSE OF BOND BEAM
VERTICAL REBAR W/ 10" HOOK—
I
30" TYPICAL
#5 BAR IN BOND BEAM
CORNER
REINFORCING OF BOND BEAM
SCALE: 3/4"=V-0
DBL. BOND BEAM
AT HIGHER ELEVATION
DBL. BOND BEAM
AT LOWER ELEVATION
#5 BAR BENT
ASSHOWN
N
0
OPEN FACE SHELL SO
AS TO ALLOW BENT
BAR TO BE PLACED IN
UPPER AND LOWER #5 MIN. REQUIRED IN
BOND BEAM EACH CELL HOOKED IN
TOP BOND BEAM W/
STANDARD ACI HOOK
CORNER BARS
3 AT CORNER STEP
SCALE: 3/4"=1'-0"
PROVIDE 3" DIA. HOLE IN
LINTEL SO THAT VERT.
REINF. BAR CONTINUES
THROUGH LINTEL.
.E REINF. BAR(S),
ROUTS BENEATH
6 SINGLE LINTEL, MULTIPLE OPENINGS
SCALE: 3/4"-1'-O"
NOTES TO THE INSPECTOR/CONTRACTOR
1. PLACE LINTEL ACROSS TOP OF OPENING..
2. IF BOTTOM STEEL IS REQUIRED PLACE #5 BAR IN LINTEL.
(�\ 3. PLACE MASONRY UNITS AS REQUIRED TO ACHIEVE THE REQUIRED BEARING
PLACE STEEL HEIGHT.
ENO REINFORCING (L2) 4. THE LAST COURSE WILL BE A BOND BEAM WITH (1) #5 BAR CONT NUOUS AROUND
AS DEPICTED HEREIN. STRUCTURE. A DOUBLE BOND BEAM MAY BE SPECIFIED SO THAT HEN THE LAST
OCOURSES ARE O
5. HODULD THE DOUBLE BOND I BOND BEAM CO NCIDE WITH A LINTEL THE BOTTOM
O� COURSE OF BOND BEAM IS OMITTED AND A LINTEL IS PLACED. THE STEEL
REINFORCING FOR THE BOTTOM BOND BEAM IS TO BE CONTINUO S THROUGH THE
TOP OF THE LINTEL.
6. LINO COMPOSITE MASONRY BEAM IS TO BE NOT LESS THAN16" DEEP.
8xl6 DBL. BON'
BEAM W/ (1) #5
EACH COURSE
8BOND
5 BAR
W (
F F = FILLED W/ GROUT BOND BEAM
(\A� U =UNFILLED GROUT SOLID FROM
S1\Q NOMINAL LINTEL TO TOP OF BOND
BEAM COURSE
WIDTH # OF #5'S, IN E BOND BEAM, IF FILLED LINTEL.
TYP.8"x8" �1#5
BOND BEAM
1#5
TYP. 8"xl6"
BOND BEAM
1
6-1 T/1 M/OB
8x8PRE-CAST CONCRETE
5�\QUO
NOMINAL—�
LINTEL W/ (1) #5 BAR (L2)
LENGTH OF BAR = WIDTH OF
p
MASONRY
Q� HEIGHT # OF #5'S, TOP
IT IS THIS ENGINEER'S INTENT , BOND BEAMCOU110E
OPENING - 2"
OR
^ BEAM DESIGNATION
THAT XFXX - 1 T/l M/OB INDICATES A DOUBLE BOND BEAM # OF #5'S, BOTTOM
8X8 PRE -CAST CONCRETE
L
SCALE: 3/4"=l'-0"
- AND XFXX - 1T/OM/OB INDICATES SINGLE BOND BEAM. PLACED IN LINTEL
LINTEL, W/O STEEL (L1) REFER
IT IS THIS ENGINEER'S INTENT -
AND XUXX - 1T/1 M/06 INDICATES A DOUBLE BOND BEAM ABOVE UNFILLED
TO PLAN FOR LOCATIONS
TOP
LINTEL
OF OPENING
AND XUXX-1T/OM/OB INDICATES A SINGLE BOND BEAM ABOVE UNFILLED LINTEL
'..
PRECASTHEADER(MIN) ----
2x4 (MIN 2 X 3) 1-3/16
TAPCON OR DRIVE PIN (MIN
SHANK SIZE.145 MIN HEAD
WINDOW
SIZE .300 MIN EMBEDMENT 1
1/4") 8" FROM EACH END AND
18" O.C. MAX. MIN 1-1/4"
EMBEDMENT
2x6 (MIN 2 X 3) 2-3/16 TAPCON
PRE -CAST —
114"
F
OR DRIVE PIN (MIN SHANK
WINDOW
z
SIZE.145 MIN HEAD SIZE .300
SILL Z
MIN EMBEDMENT 1 1/4") 8"
FROM EACH END AND 18"
SLOPE
O.C. MAX. MIN 1-1/4"
r
M
t
EMBEDMENT
TYPICAL MASONRY WINDOW
SILL CONSTRUCTION
SINGLE #5 CORNER —
BAR, 30x3O TURNED UP
OR TURNED DOWN INTO
FILLED CELL
_�-
Ie�
SCALE:1
'I STEEL REINF. OF
BOND. BEAM
PROVIDE #5 BAR
STEEL REINF. OF AT EACH SIDE
BOND. BEAM OF ELEVATION
CHANGE
CHANGE IN
ELEVATION OF BOND BEAM
2x8 (MIN 2 X 3) 2-3/16
TAPCON OR DRIVE PIN (MIN
SHANK SIZE.145 MIN HEAD
SIZE .300 MIN EMBEDMENT 1 2X4 SOLID BLOCKING
1/4") 8" FROM EACH END AND SECURE TO SHEATHING W/
18" O.C. MAX. MIN 1-1/4" MIN. 2-12d PER ELK. EA. END Reviewed for Code
EMBEDMENT Compliance
7/16" OSB SHEATHING UniveS�lBCeseenog
CMU WALL
5 ARCHWAY FRAMING DETAIL
2194 HWY AIA, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937.
PH: 321-802-3591
www.abdesigngro4p.com
AA #: 0003325
111111
a
5
anon OEM
SL p-MN7 ctt LOT:
CREEKSIDE
P SE
LOT # 2 5
PROJECT#
04321.200 025R1
MODEL:
4EAB
"1672—ARIA"
GARAGE SWING'
RIGHT
PAGE:`n
DETAILS
j
i
KS�Cr 1011 EXP. C
Y,.
ARCHrrECT_
STATE OF FLORIDA
MAR' 19' 2021
MICHAEL C. ANDERSON
AR NO T7305
PRINT DATE: 03 17 21
SCALE: 1 /4"=1' = 0
SHEET
F �i Ytl.
O
0
"
"LOTT'S CONCRETE" / "CAST-CRETE" / "QUALITY" SAFE LOAD TABLES
SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELSFF SAFE LATERAL LOADS FOR SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS
SAFE
LOAD -
POUNDS
PER LINEAR
FOOT
SAFE
PLF
LOAD
TYPE
GTH LEN
8U8
818-08
8/16-1T/013
/20-1T/OB
/24-1T/0B
/28-1T/0B
/32-1T/0B
TYPE
LENGTH
8/8 PLAIN
8/8 SOLID
8/8-1B
8/16-1T/1B
120-1T/1B
/24-1T/1B
/28-1T/1B
/32-1T/1B
3'-6" PRECAST
1436
952
3114
4217
5321
6426
7531
3'-6" PRECAST
689
1024
2465
6113
6385
7708
9031
10000
4'-0" PRECAST
1065
700
2305
3125
3945
4765
5587
4'-0" PRECAST
514
763
1961
6113
7192
6524
7627
8751
4'-6" PRECAST
819
533
1770
2400
3033
3666
4300
4'-6" PRECAST
398
591
1625
5743
7547
6752
6541
7565
5' 4" PRECAST
931
1247
1999
2560
3123
3686
4249
51-4" PRECAST
411
411
1319
4460
7196
7342
5780
6259
5'-10" PRECAST
817
1024
1631
2090
2549
3009
3470
5'-10" PRECAST
340
339
1161
3693
5877
6036
6548
5776
6'-6" PRECAST
692
1139
3227
3031
3707
4383
5061
6'-6" PRECAST
410
721
1139
3227
4598
7054
10000
8825
7'-6" PRECAST
570
938
2498
2205
2698
3191
3685
7 -6" PRECAST
303
534
938
2498
3408
4864
7067
6472
9'4" PRECAST
428
633
1593
2204
2481
2818
2621
9'-4" PRECAST
192
384
639
1674
2298
3081
4099
4899
10'-6" PRECAST
388
487
1247
1767
1904
2163
2028
10'-6" PRECAST
151
301
550
1407
1897
2781
3222
3784
11'-4" PRECAST
330
544
1312
1742
2252
2868
3630
11'-4" PRECAST
132
417
544
1312
1742
2252
2868
3552
12'-0" PRECAST
308
507
1210
1596
2048
2586
3191
12 0" PRECAST
111
370
507
1210
1596
2048
2586
3171
1IT-4" PRECAST
270
433
1045
1365
1732
2157
2535
13'-4" PRECAST
82
298
414
1045
1365
1732
2316
2605
14'-0" PRECAST
254
388
978
1272
1606
1988
2279
14'-0" PRECAST
71
293
390
978
1272
1606
1950
2389
14'-8" PRESTRESSED
N.R.
NR
NR
NR
NR
R
NR
NR
NR
NR
14'-8" PRESTRESSED
N.R.
283
1
1NR
2NR
2NR
151-4" PRESTRESSED
N.R.
NR
NR
NR
NR
NR
NR
15,-411 PRESTRESSED
N.R.
252
412
1014
1340
1703
2118
2513
17'-4" PRESTRESSED
N.R.
NR
NR
NR
NR
NR
NR
17'-4" PRESTRESSED
N.R.
183
300
856
1121
1413
1739
2047
19'-4" PRESTRESSED
N.R.
NR
NR
NR
NR
NR
NR
19'-4" PRESTRESSED
N.R.
148
235
736
959
1200
1467
1716
21 -4„ PRESTRESSED
N.R.
NR
NR
NR
NR
NR
NR
21'-4" PRESTRESSED
N.R.
125
180
598
833
1038
1168
1468
22'-0' PRESTRESSED
N.R.
NR
NR
NR
NR
NR
NR
22'-0" PRESTRESSED
N.R.
116
165
550
784
992
1203
1381
24'-0" PRESTRESSED
N.R.
NR
NR
NR
NR
NR
NR
24'-0" PRESTRESSED
N.R.
91
129
450
654
824
1014
1147
SAFE LOAD - POUNDS PER LINEAR FOOT
TYPE
LENGTH
8/8-1T
8/16-1T
8/20-1T
8/24-1T
8/28-1T
8/32-1T
8/8-2T
8/16-2T
8/20-2T
8/24-2T
8/28-2T
8/32-2T
3'-6" PRECAST
1569
3524
4394
5263
6132
7001
1569
3524
4394
5263
6132
7001
4'-0" PRECAST
1363
3060
3815
4570
5325
6079
1363
3060
3815
4570 1
5325
6079
4'-6" PRECAST
1207
2582
3375
4043
4711
5379
1207
2707
3375
4043
4711
5379
5'-4" PRECAST
1016
1806
2374
2944
3513
4084
1016
2276
2838
3399
3961
4084
5'-10" PRECAST
909 1
1499
1971 1
2443
2915
3387
929
2080
2593
3107
3620
4133
6'-6" PRECAST
835
1201
1578
1955
2332
2709
835
1868
2329
2790
3251
3712
7'-6" PRECAST
716
900
1181
1462
1743
2025
727
1624
2025
2426
2827
3228 11
9'-4" PRECAST
454
586
767
948
1129
1310
572
1318
1643
1969
2164
2519
_
10'-6" PRECAST
356
468
612
755
899
1042
504
1180
1472
1763
1710
1989
11'-4" PRECAST
430
406
530
653
777
872
466
1042
1372
1643
1470
1710
12'-0" PRECAST
383
366
476
587
698
783
440
940
1300
1560
1314
1476
13' 4" PRECAST
308
303
393
484
575
645
396
780
1057
1312
1071
1203
14'-0" PRECAST
279
278
1 360
443
526
609
378
717
961
1192
975
1133
14'-8" PRESTRESSED
239
422
506
626
746
865
246
663
980
1237
1474
1715
15'-4" PRESTRESSED
224
387
464
574
684
793
230
616
908
1134
1353
1572
171-4" PRESTRESSED
187
326
365
451
587
680
192
506
720
501
1135
1 1312
19'-4" PRESTRESSED
162
266
348
430
513
595
166
429
623
803
950
1098
21'-4" PRESTRESSED
142
219
308
381
454
527
142
1 373
537
690
816
943
22'-0" PRESTRESSED
137
226
290
359
428
497
137
358
513
659
779
900
24'-0" PRESTRESSED
124
174
245
302
360
418
124
319
455
581
68-1
793
- ALL VALUES TAKEN AS THE LESSER FROM "SAFE LOAD TABLES" BY QUALITY 2018 EDITION, LOTT'S MAY 2015 EDITION - PRECAST PRODUCTS BY OTHERS TO MEET OR EXCEED VALUES STATED ABOVE
AND CASTCRETE MAY 2015 EDITION.
- ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS - PROVIDE MINIMUM 4" OF BEARING PAST EACH SIDE OF WINDOW OPENING
PRODUCT CONTROL NOTICE OF ACCEPTANCE F.E.C.P. CORPORATION-CASTE-CRETE
DIVISION ACCEPTANCE #: 19-0130.13
Reviewedfor God'
Gomplianc'
Universal En9ineenn9
seances
2194 HWY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325 J
SUBDIV. & LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT#
04321.200 025R1
MODEL:
4EAB
"1672-ARIA"
GARAGE SWING:
RIGHT
PAGE:
SAFE LOAD
TABLES
160 MPH E . C
mm
ARCHrrECT
STATE OF FLORIDA
MAR 19 2021
MICHAEL C. ANDERSON
AR NO 17305
rrcaar . DATE: 03 17 21
I SCALE: 1/4"=1'-0" 1
SHEET
tS2e2A
FRAMING NOTES:
1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE
CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 1Od x 1 1/2" HDG NAILS.
CONCRETE TO WOOD FLOOR:
SIMPSON LTA2 W/ (8) 1 Od x 1 1/2" HDG NAILS, WOOD TO WOOD:
SIMPSON H1 OA OR LGT2 W/ 1 Od x 1 1/2" HDG NAILS, FILL ALL HOLES.
2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER
SCHEDULE.
3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE
MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS.
4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS
ARE TO BE GALVANIZED:
5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON'CAST-CRETE,
CONNECTERS ARE TO BE GALVANIZED.
6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE
CONCRETE LINTELS.
7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND
CLEAR SPAN OPENINGS.
8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4").
9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE
SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE
FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINAL TRUSS DESIGNERS
LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND
APPROVAL.
10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES
SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED
FASTENER, ZF 72 P8S36, .177" 0 x 2 7/8' LONG, WITH WASHER @ 16" O.C.
11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END
UNLESS OTHERWISE SHOWN DIFFERENT.
12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON
RATIONAL ANALYSIS.
13. ALL ELEVATIONS ARE REFERENCED FROM U-0", FINISH FLOOR. UNLESS
NOTED OTHERWISE.
14 BOTTOM CHORD BRACING, DIAGONAL BRACING AND GABLE END BRACING
SHOWN ON THE FRAMING PLANS AND DETAIL ARE DRAWN AS A DIAGRAMMATIC
PURPOSES FOR MINIMUM SPANS AND MAXIMUM SPACING. THESE DRAWINGS ARE
INTENDED AS A GUIDELINE FOR CONSTRUCTION AND DO NOT NECESSARILY
REFLECT ALL ACTUAL CONDITIONS THAT MAY ARISE IN THE FIELD. FIELD
CONSTRUCTION SHOULD CLOSELY PARALLEL THE BRACING DIAGRAMS WITHIN
GI DER�TRUSS
W 2X6 BOTTOM
CHORD
TRUSSES W/2X4
BOTTOM CHORD
THESE MINIMUM AND MAXIMUM TOLERANCES. ADJUSTMENTS IN THE FIELD ARE 2 4 SCAB NAILED TO p/I DIAGONAL M
ACCEPTABLE FOR FIELD CONDITIONS SUCH AS INTERFERENCES WITH TRUSS T USS BOTTOM I/J�(I BRACING
END JACK:ff ILAVI
WEBBING, SHEETING ETC. IN SITUATIONS WHERE THE DIAGRAMS LOCATION AND c OR W/MIN (4) 10d
ACTUAL TRUSS WEBBING CONDITIONS CONFLICT, THE CONTRACTOR SHALL PLACE WHERE APPLICABLE N ILS OR EACH CHORD BRACING
THE DIAGONAL BRAE ADJACENT TO THE TRUSS WEB AS CONDITIONS ALLOW. CHORD CONNECTION
DISSIMILAR BOTTOM CHORD BRACING @ END
i A - aC2LE: PLT2
TRUSS MANUFACTURER / ENGINEER NOTES:
1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 LBS SHALL BE
FABRICATED W/ A 2x6 BTM. CHORD (MIN.)
2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND IATTIC ACCESS
WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT
SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION AND MISTAKES.
3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO
TRUSS CONNECTIONS.
4. AVOID PLACING A TRUSS PERPENDICULAR TO A STEEL COLUMN.
MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN.
FOR EACH CHUHU
CONNECTION
DISSIMILAR B0`1I'TOM CHORD BRACING 0 MID RUN
( i rI I ecxe: WfAN
CONNFCTORSC EDULE
( UNI 1.1 DATE m/$1/2Dz0
" MIIeR LISP
SIMPSON
MiTPN LISP
SIMPSON
DES.
UPLIFTGRAVITY
DES.
UPLIFTGRPVNY
A
FASTENER
I'
N iP 161fl
162,META-16
145.M
18f10IRA x 11/2°1-PLY 17l Ind ?-PLY, FM3EDL'
(B)im X 11/2 ]PLY OF IRS 2PLY fMBkD4
I
(21 YEA 1610
loll
(21,METAO6
198E
(22)IN I 11/2'•1-0LY FMBF04
(10)TOtl K 11/2'1PLY EMBEJ4'
ETA 16
LBJO
FEES 11
All
UO) 1.. 1 Uzt(I PAT PR'F.I'D,
(1)111 1 1 1/1'']PLr IB) FAR 2 PC, EMBEDa
NEA 20
1670
1El IR
-I810
Ill,ING x11/2',(E)III 2RLY, fMBED4"
(9)JOEx11/2" 1'PLY,(91 lm 2 PLY,, EMSEDW
(1)HW IG
Ff30
(21 HETA-20
203E
(12)tOd vl 1/2', 1-P L'I,fMBED4"
(]E)10d x 11/2'• I PLY, REPAIR.'
25M
(10116d 2 PLY EMBER 4
Fl2FAA 2-PLY, EMiBED4"
Z
LUGi2
]fi55
i
LOT
1885
Bl%IS)fl/1"e 3'WPtl8R9 X Anchors, WW0(16)lm
(7)-I/4 x2]/4 TITEN, W(JW (ifi)]fid
C]
LUGTd
9380
W13dP52.S
3480
111110(4)A/8 x5' Wed Re 3011A^Cho1A WOOD (12) W525
(]z)SD5FEVRE'TO ORDER, (4)3/B" xS THEN HDTO WALE
BETIDE
2430
ORFA420
2480
1IS) -INx1112, 3 PLY ALTERNATE USE OF R) HTAI20 ACCEPTABLE
Ia) INK 11/21 PLY ALTERNATE USE OF12) HFTA 20ACCEPEARIF
MJGT35+
3945
AT.
3B65
IJjS/0'AR: IN HIGH STRENGTH EPDXY IMIN, 12' EMBfD),(2211m IOWOODI
ill 5/B°PiR. IN HIGH SFRENGTH EPDXY (MIN, TO EMBED),(721BED
ID WORD
H JGT2+
957S
XGT-24
1490
•
WOOD tl8) 1OR, MASONBY(21WN' A.T.R.
(213/4°A.T.R.IN.HIGH STRENGTH EPDXYIMIN. 12' EMBED).(161 HERTO
WOU
HVGT3+
SEEN
HGT-3+.
10690
WOOD E B I I Ed, MASO N BY(213%4 ". AT 1
1213/4"A.T.R.1%HIGH S(IiENGTH EPDXY (MIN 12" EMBED), 1611
M IN WW
LPTA
1510 PARALLEITU WALI
1490 PERPEND I CUARRI
LTP2
1210 PARALLF LTO WALL
1219 PE RPfNDImEARTN
WALL
UB)IDax 11/z'
60p0tl x1-z/z"
MUGT15
3945.
VGT
AS.
IN51WAI IT IN HIGH STRENGTH EPDXY(MIN_FREEMBED),(4)ILL TOP/(G) 10d FACEj(12f 10tl NAC%OF iPU55
IN STRENGTH EPDXY MIN 12"[MtlEO 16 S
IS)5/0 Pi. R:I ( 1.( )
514"r3"
/.
HUI•II
EVIL
(2f VGT
I.
(2)SIDIATR.IN HIGH STRENGTH EPDXY (MIN. 11' EMBEDI,(8) lm
(2)5/8 ATR. IN HIGH STRENGTH EPO%VIMIN I$"fM9f0), (321551/4"x>'.
MPWI2
965
MisII
990
(14)1Otl X 11/2't F1411m
(14)101 x 11/2•
IT. 16
135E
HTs46
1910
(16)IOtl 11/z°.Ufi112
P6)FEE x li/2"
HTw zD
1355
FEE SO
1310
(2A lOdxIz"jlm
(z4) DEC xv/2•
HTw24 +
BASS
"T524
1310
(24INS A11/z°,FDRIW
(24)10d xI VP
LSTA 12++
BUT
L51A 12
925
(1011.
DO) FBI
61A 18+Y
1235.
LRA 18
1235
(11) 1.
(141ITS
MSTA R$++
1310
MSTA ]B
]i'S.
His, Itl1.
ITT FORE -
BSTAA
1.0
11TAz4
1640
(18)1N
PAT Tho
MSTA-31µ
COGS
111A.30++
SUED
12"lao
(PUT PRE
a
p
MSTA.Nµ
z06s
11TA-36++
$DSO
Inn)IN
OH) IN
tq
It5TI236
ZJ6s
11T3A
ABM
(Ill IN xv/z-
) FEE 111/2"
NIEIJ48
11.
11TILB
5010
I48NN A1112'. I
1491 LOS A11/2'
LFTpb
9B0
H6.
1055
I1L BA v11/2".D EA)B
1 )
8 l0P IE 5.STUDS 31 U05
SPT4
%>5
SP4
825
(6(1C0 TO SNE5 (6)10T0 %ATE
N 10tl e1 j/2'
-
MP34
S
�2'IN F]@]60N
A31
430
14)8A%11/2"TOdEWM114)Etlx41/2'TO PoST
(0.18tlx]1J2"TO REAM, (4)Btl BE l/$"TOfCST.
4)EdA1122O 6EANs
PIECES
PAT
HCP2
EST
hNJJFEX1IJU.MO RUSS,IIDI40tl X1112-TOPRTE
l 1 /"
RTIE.A
1021
H10A
IWO
(9)�XI1/7. TO lOussgel lOaxll/2"IOPUTf
OAT10,Avn"
-
MLIGl15 A EEL
- utO UOD
I TRU55 O WSl \NOOD SL:REWSTOPOSTW e8"TXRFP
D-51>S xl1 $"W IHREADFO
16 s0s1 a"x3"TO w000, 11 / / /
( /
OD I VU
5/W R/2
ASH PLY
MUGTJU W.4
4175
VGT&HD8
49.
120)1.1.1'ROSS.(S0WAR WOOD SCREWS TOWHT W/5/8'THREADED BUD
(IE) PUS 1/4"13"TO WOOD,(3)3/4" s TU 130LI S W/ I THYROID
ON (2) NU
WAShEIL71
253E
6715
ABU 442
J31M
]]50
FIN SIR AI.O.IN HFOR STRFNLiH FP(%Y,IJ'E MINM1I.)INCANG,(12111FT..000
(1)5/3 A T. R. IN HIGH STRENGTH EPDXY, (MN J" EMOER) IN CAN
1
C,(1]Al
ID WOOD
PAU66
245E
160m
ABU BED
11.
RANI.
(115FJA➢R. IN HIGH STRFNGT H EPO%V.f.IN .]" EM BED) IN CONIC., J1211U 1O.01
(1)5/8"A:T.R. I N H IGH STRENGTH EPDXY, (MIN J"FEARED .)INC
NO., 112)164
TO WOOD
L1119 µ+
1S
LU39ITT
1310
(2)3/4"AT1. 0 IN HIH STRFNGT H EPLAY, (MIN 7- EMBED) IN CONY, B)1m TO WOOD
(1)3/4"A.T.R IN HIGH 5 TRENGTH EPDXY, (MIN.]°f ME",1 Ann!
C, (8)1m
OW000
LTS]03 µ+
JIM
LTT20B µ+
1509
11)3/4' A.TR. IN HIGH STRENGTH EPDXY, (MIN .]' EMBED) IN CONC, IIO)1 A x 1N/2 TO WOOD
(1)1/2"AIR.FEE HIGH STRENGTH EPDXY,)MIN. ]'.EMREDIIN CO
G,(10)1
TO WOOD
GO
BEHAR
41M
h14
4455
(1)5/B'A:I II INHIGP STRENGTH EPO%Y.(MIN. 2'f ING.JINCONC-ElD Cd%)1/)"
(3)S/9"A:IN. IN HIGH STRENGTH EPDXY )MIN.]°EMBPO)IN CON
,(2611W
IX]1/YY'
$
HTT45
ST.
NTR
so.
IF) 51W AT. R. IN HIGH 5TRENGTH EPDXY (MIN. T' EMBED) NCONC,G&)]m x21/2'
ill Bol'AT.R. IN HIGH STRENGTH EPDXY (MIN AEMRFDJINCUP
.FREIIRS
%2]/Y'
Q
UIH Or1+
ifi
H"1%1111.1
2S+
I]Rt9
p l'F.T•R. IN IT STREN6THfP0%Y,IMIN.10"EMBfD)IN CONY., (26)W53 \NOODSCRFWS
Ill 1"AT.ft: IN HIGH STRENGTH EPDXY, RAN. 10" EMBED.) IN
NC,(24150�%°N25"N'CCUSCAENS
RFDSA
TDSB
S25
]8]fl
HD]a
66as
(1f5/fl"A.9.IN HIGI(STRENGTH fPO%V,IMIN]"EMBED INCNY C.(14)W9 W000 SCREWS
(MIN]MBED] N CONC(31
Ill//P"A.9.IP HE, H STRENGTH EPDXY, (MIN. T' EMBFO_)INC
-, (3f 3/4"iTUO
ROUY EGA:
(])1/RA.B. IN HIGH STRENGTH EPDXY, EA' STUD BOlI5iOW000
NFM35 %12V
2500
7130 TI56/11]$
MS.
3415
5330
(11 t13"I'BOLT IN MIN 6" EMBED &NOT LESS THAN 4"FROM FOGS OFCONCW/3/4"CIA EW RPMSEI/REDHGD.1113/4'A.T
DV NA BOLT SLEEVE A NCHOR OR TO W/MIN 5'E M B ED INSTALLED IN FACE. 14GId AT JOIST
.R IN F IGH STRMGI' H F PLAY, (MIN. 6.J5"EMU EC MEN
E POPPY, (MIN 6.20"EMBEDMENT) I N C.M. V. FACE, JIB) 10d TO BE
IINC M. U.IlOFF
1113/4' A IR IN NIGH SIRENS IH
NUS4121F
361E
271E11mt5)
xu9rntr
IWWD1
343E
2fi3s 11MiFl
(lE)1AA'I O HEA (10) TOW"`OD
(III) IRS TO HFPDER. (1016tl TO WOOD
(1211)
3323ESR
32245005X.
N
IV
LD
Z
HIMUDE (NU
( )
FARE
(CMU)0
1ACT
Rf
W Al' �•SP (J'W531i5CREW5, (]OI]m TO
(]R V x3.03/1R""TAPPER+:I]OI]IXI iO WOOD
(]8)1/4x2d/4..TNEN (9 PER FLANLiF)If]INU, (10)]m TO WO
xD21621F(CMU)
1950
308D
PECS112
(CN UI.
1800
4500
(I8)iA'e3W931SCRFWS,(30)3W i0
Wes® USP (20 ll/ "TPPPE R+, (1 I) 1m T.WCOD
(1611/4"X2-3/4 ilifN (YYfRFLPNGE)iDCMU,p0 10tl TOW
D
x 021 O-31F(CMl))
1]95
501E
HU12113
(EXID)
1000
4500..
I1H114 ,a W595CRFW5,Flr)1m TO
IM111 ill, (20)3/lA TAPPER+, (10/1m TOWOOD
18)1/4x 2A/4 TITEN (9 PER FL4NGE)iOCMly lI0110dTOWW
LGUM26-2
2125
6L61
ISOMERS5D
1430
5595
(4)419'%4"Welge BOlb AnlhOrq W000(4).WCODSCREWS
(4)318.i4TITEN HDANCHORS(2 PER FIAN6EITO GMU,(TVA
2-1/$505s
IiEWSTO WI]OD
ULU
1A
i
� U
0 O
O
CO o
CE N
O (aj
C7
Z
Q U
ZQ
O m
orr
O
2X4 BLOCKING BETWEEN TRUSS S 24" O.C. TOE
NAILED TO ADJACENT TRUSSES / (2) 16d COMMON
TO NAILS & SECURE TO BM. W/ SIMP ON LTA2 USED TO
y✓� �j 5j BRACE TOP OF WALL. v u Z�
II 3
CJ1
CJ1EJ7h IIw k I II 1
II e
CJ3 = I nW a 11 uLL' n n n n n n n n 11 11 SI T) CJ3 -
1 1 C I 11 ATTACH 4,-0" LONG 2x SCAB TO 11 11 11 11
CJ5 = u n 3A n 11 TRUSS W/ 1 Od NAILS @ 6" O.C. u u u n = �� CJ5
F
(4j1 FROM A. END)
I
GT g10G
==:b=_____
6
A
= A
y�A X\Q I�
_ ___ ___ _____ A =
:
_A2
PR -FABRICATED ROOF
TR SES @ 24" O.C. MAX.
=7
1.
L A1A
\ I/ ___ _
- =szF11L- <IF
JL
,
1
I
ATTIC I
ACCES_ S _ A3'
A4
- - - - - - - - - - - - - - - - - - - - A5
V4
A9
1 A'
3.1 ASG
CJ5 - n n Is- v > 1 A O
II II WTI" �- - - --- - - - I
II 3.1 _7-7 _I
7 m
CJ3 = II u u I o
j
3.1
CJ1 II II �d o J7A n
U U
W
7
0 8
0
rr
3.1 S 3.1 B
FRAMING PLAN
SCALE: 1/4" =1'-0"
1A
Reviewed for Code
Compliance
93 UnlvePsal Engineenng
Sciences
1
2194 HWY AJ.A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-359�
www.abdesigngroup rom 4
AA #: 000332E
0
Fill
So
Is
\j\
A,
( 6,
:E
= 1
SLTBDIV. 8e LOT:
E
CREEKSIDE
El
PHASE `2
LO T # 215
PROJECT#
04321.200 025R1
MODEL•
4EAB
"1672-ARIA"
GARAGE SWING
RIGHT
f
PAGE:
FRAMING
PLAN
t-
Ir,A
11
160 MPH EXP d
ARCHrrECT:
STATE OF FLORIDA
MAR 19 2021
MICHAEL C. ANDERSON
AR NO 17305
PRINT DATE-
03 17 21
SCALE: 1/49f=1'-011
SHEETT\T
Imo._/ 3
C,
A-(1) SIMPSON HETA16 TRUSS ANCHOR WITH
SHEATHING,
(9) 10d x 1 2" NAILS TO TRUSS
ROOFPLYWOOD
WALUFLOOR
B-(2) SIMPSON HETA16 TRUSS ANCHOR WITH
SHHEATEAT
SHEATHING
(12) 16d x 1 2" NAILS TO TRUSS
FASTENER SCHEDULE"
DBL STRAP, 1 EACH SIDE WRAPS UP AND
OVER TRUSS (NOT SHOWN)
C-(1) SIMPSON LGT2 GIRDER TIEDOWN WITH
NOTE: A PT SYP #2 2" x
(16) 10d x 3 �' NAILS TO GIRDER AND
6", 8" x 4'-0" MAY BE ADD
(2) SIMPSON HETA16 TRUSS ANCHORS
W/ 10d NAILS, 2 ROWS, 3'
WITH (12) 16d x 3 2" NAILS TO GIRDER
O/C TO FACILITATE ONE
ADDITIONAL PLY MAX. T
1x2, 2x WOOD FASCIA
ACCOMMODATE TRUSS
SEE ARCHITECTURAL
ANCHOR REQUIREMENT
2x SECURED W/(3) 16d
GALV. COMMON NAILS.
—
ENGINEERED WOOD
1 x2 SECURED W/ 10d
TRUSSES @ 24" O/C,
GALV. COMMON NAILS
SUBMIT SHOP DRAWINGS
12" O/C
FOR REVIEW
AND APPROVAL
MASONRY BOND BEAM
SEE SCHEDULE
A ALLOWABLE UPLIFT
= U:, 810 LBS, L:770 LBS (1 PLY)
B ALLOWABLE UPLIFT
= U:2365 LBS,, L:1430 LBS (2 OR 3 PLY)
C ALLOWABLE UPLIFT
= U:2705 LBS (2 PLY)
00, TYPICAL TRUSS/
1a 1b 1C GIRDER
CONNECTOR(S) SGALE:3/4"=''.°"
NOTCH DEPTH 1/4*Dll
HOLE EDGE >5/8"
HOLE DIAMETER
a 2/5*D SGL. STUD
OUTER 1/30F -
SPAN ONLY
HOLE EDGE >5/8"
BTM. HOLE DIAMETER
PLATE <3/5*D DBL. STUD
STUD NOTCHING
AND BORING LIMITS
SEE
4
ENGINEERED WOO TRIVSSE PLYWOOD SHEATHING, SEE
@ 24" O/C, SUBMIT HOP "ROOF/WALUFLOOR
DRAWINGS FOR R VIE SHEATHING
AND APPROVAL FASTENER SCHEDULE"
(1) SIMPSON HETA 6
TRUSS ANCHOR ITH NOTE. A PT SYP #2 2" x 4",
(9) 10d x 1 2" NAILS O 6", 8" x 4' 0", MAY BE ADDED
GIRDER. PROVIDE ' W/ 10d NAILS, 2 ROWS, 3"
MINIMUM CONCRE E O/C TO FACILITATE ONE
EMBEDMENT. USE IN ADDITIONAL PLY MAX. TO
CONJUNCTION WI H ACCOMMODATE GIRDER
ED
HEAVY UPLIFT TIEDOWN REQUIREMENTS.,
CONNECTOR *`
O
A- t SIMPSON LGT3-SDS2.5 GIRDER TIEDOWN
'I WITH (4) x 5" TITEN HD TO CMU AND (12) SIDS
S.
4"x22"TO GIRDER
B-(1) SIMPSON FGTR GIRDER TIEDOWN WITH
(2) 2" x 5" TITEN HD TO CMU AND (18) SIDS 4" x
1 x2, 2x WOOD FAS IA 3" TO GIRDER
SEE ARCHITECTU AL
C-(2) SIMPSON FGTR GIRDER TIEDOWNS WITH
2x SECURED W/ (3)' 16d
(2) 2" z 5"TITEN HD TO CMU AND (18) SDS 4' x 3"
GALV. COMMON NAILS.
1x2 SECURED W/ 10d MASONRY BOND SCREWS TO GIRDER (EACH TIEDOWN)
GALV. COMMON INILS BEAM ENSURE THAT CELLS ARE GROUTED
SEE SCHEDULE
12" O/C SOLID, 8" EACH WAY OF BOLTS
ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY)
iA
B ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.)
C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.)
TYPICAL ROOF
2aI 2b 2c GIRDER CONNECTORS) scALE:3/a"=1'o"
6-0" MAX (W/1 X4)
1 10--0" MAX (W/2X4)
# 1100 UPLIFT SI PSON
HTSM20 W/1010 TO
TRUSS AND (4) 1/4" x 2 1/4"
TITEN 2 ANCHORS TO
CONT POURED LINTEL
# 1900 UPLIFT (2) SIMPSON
HTSM20 INSTALLED ON PRE-ENG TRUSS
OPPOSITE FACES OF
BLOCK WALL W/ 0 10d TO
TRUSS AND (4) 1 4" x 2 1/4"
TITEN 2 ANCHORS TO CONTINUOUS BOND BEAM
CONT'POURED LINTEL
--- TITEN 2 ANCHORS MIN.
2" COVER & 2" APART
REPAIR OF MULTIPLE
MISPLACED EMBEDDED TRUSS ANCHOR
:3) SCALE 3/4"=1'-0"
(2) 2X4 No-2 SYP DIAL. —
BRACE W/ (3) 12d @ EA.
TRUSS (DIAG. BRACE TO
COVER 5 TRUSSES)
0'-0" TO 30'-0" (1) "X" BRACE
30'-1" TO 60'-0 (3) "X" BRACE
(1) "X" BRACE @ CENTER
(2) "X" BRACE DIVIDED EQUALLY
FROM CENTER TO END.
2x WOOD FASCIA,
1x4 DIAGONAL SEE ARCHITECTURAL
BTM. CHORD PRE-ENG GABLE TRUSS
BRACING, SEE
PLAN FOR LOCATION STIFFBACK (AS PER -
MAY NOT BE TRUSS ENG)
REQUIRED
BTM. CHORD OF
WOOD ROOF TRUSSE
1 x4 BTM. CHORD BRACING 6-0" O/C END WALL OR OTHER
MAX., OR 2x4 BTM. CHORD BRACING END TYPE CONDITIO , IF
10'-0" O/C MAXSECURED W/ (2) 10d DEPICTED SEE PLAN
COMMON NAILS AT EACH CHORD
INTERSECTIONTYP: G BTM. CHORD BRACING
2x4 BLOCKING BETWEEN
TRUSSES WHERE
X-BRACING IS PRESENT AT
4'-0" O.G. (AT SHEATHING
SEAMS)
SECURE 2x PT. PLATE
TO BLK W/ 1/2" DIA-
ANCHOR BOLT W/ 2"
WASHER SET IN HIGH
STRENGTH EPDXY 6"
MIN. EMBED. AT 32" OC
MAX.
SECURE GABLE TO 2x8
P.T. PLATE W/ 12d's 8"
O.G. MAX
CONT.2x4 SECURED W/ I
(2) 10d's @ EACH TRUSS
TO BE INSTALLED @
10'-0" O.C. MAX.
SEE SCHEDULE FOR
BOND BEAM REQ.
Reviewed' an ode
pomp lneenng
UniverSGences
7 BLOCK WALL W1 GABLE END
PRE-ENG'D TRUSS scALE:3/4"=,'-°"
THE USE OF ALTERNATE MATERIALS MAY BE
USED SO LONG AS THEY CONFORM TO THE
FOLLOWING
1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS
A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS
EQUIVALENT OR GREATER UPLIFT AND LATERAL (F1 AND F2) LOAD CAPACITIES
AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND
ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE
THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO
A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2
FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE
SUBJECT TO F1 AND F2 FORCES.
11 ALTERNATE MATERIALS
SCALE: 3/4"=1'_®''
1194 HWY A1A, SUITE 301
NDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abipsigngroup. m
AA `' 0003325 '
DEW
1
SU V, s a" °.r n
y
CREEKSIDE
PHASE :2
LOT # 2'5
PROJECT*
04321.200 025R1
MODELS
4EAB
"1672-AR''IA'
.AOR—A. E SWING
RIGHT
PAGE:
DETAILS
160 MPH EXP. C
ARCHM=Z37:
STATE OF FLORI )A
1 9 �._ C 21w
�4Per°r a DERSON
AR NO 17305
[SRINT 03 17 21
ATE:
SCALE:1/4 l'-0"
SHEET
S3.IA
a
PRE-ENG GABLE TRUSS
2x4 BLOCKING BETWEEN TRUSSES
AT FIRST TWO BAYS 4'-0" O.C. (AT
SHEATHING SEAMS) (BLOCKING
NOT SHOWN FOR CLARITY)
2X4 DIAGONAL BTM. CHORD
BRACING. SEE PLAN FOR
LOCATION
SECURE 2x6 PT. PLATE TO BLK
W/ 112" DIA. ANCHOR BOLT W/2"
WASHER SET IN HIGH
STRENGTH EPDXY 6" MIN.
EMBED. AT 32" OC MAX.
SECURE GABLE TO 2x8 P.T.
PLATE W,i 12d's 8" O.C. MAX
U
0
CONC.POURED
LINTEL COURSE
PRE-ENG'D WOOD
TRUSS (TYP) @ 24" O.C.
MAX
FOR STRAPPING
VERIFY
W.-TRUSS PLAN
-'� CONT. 2x4 SECURED W/ (2) 10d's @ EACH
TRUSS TO BE INSTALLED @ 10'-0" O.C. MAX.
GABLE END BRACING W1 PRE-ENG
GABLE TRUSS @a CMU WALL
SCALE: 3/4"=1'-U
Reviewed for Code
Compliance
Universal Engineering
Sciences
2194 HWY A1A, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdesigngroup.com
AA #: 0003325
SUBDIV. & LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT*
04321.200 025R1
MODEL:
4EAB
"1672-ARIA"
GARAGE SWING:
RIGHT
PAGE:
DETAILS
160 MPH EXR C
ARCHITECT.
STATE OF FLORIDA
MAR 192021
MICHAEL C. ANDERSON
AR NO 17305
DATE: 03/17/21
SCALE: 1/4"=1'-0"
SHEET
S3e119
r
vH
711111111111111111
(2) 2X4 No.2 SYP DIAG. 2x6 OUTLOOKER @ 24" O.C.
BRACE W/ (3) 12d @ EA. SECURED W/ SIMPSON H10A
TRUSS (DIAG. BRACE TO
COVER 5 TRUSSES)
2x SUB -BAND
0'-0"TO 30'-0" (1) "X" BRACE
30'-1" TO 60'-0 (3) "X" BRACE
(1) "X" BRACE @ CENTER
PRE-ENG GABLE TRUSS
(2)"X"BRACEDIVIDEDEQUALLY
STIFFBACKATALL
FROM CENTER TO END.
UPRIGHTS OVER 4'-10"
HIGH'
(AS PER TRUSS ENG)
PLYWOOD SHEATHING, SEE
"ROOF/WALUFLOOR
SHEATHING
FASTENER SCHEDULE"
SEE TYP. TRUSS CONNECTOR
DETAIL FOR STRAPPING INFO.
=
CONNECTION PER
1x2,2xWOO D FASCIA
TRUSS MFG.
SEE ARCHITECTURAL
2x SECURED W/ (3) 16d
ENGINEERED WOOD
GALV. COMMON NAILS.
TRUSSES @ 24" O/C,
1x2 SECURED W/ 10d
SUBMIT SHOP DRAWINGS
GALV. COMMON NAILS
FOR REVIEW CONT.2x4 RAT RUN
12" O/C
AND APPROVAL SECURED W/ (2) 12d's @
e
EACH TRUSS
MASONRY BOND BEAM
SEE SCHEDULE
,�BLE `END
PRE-ENG'D T��UjrCrTInrj�
1
Scao•
e
SIDE VIEW
VTCR SPACING (1) AT EA(
...- ,,, -1. 1.
PRE-ENGINEEF,��
2 VALLEY TRUSS CONNECTION
R('.Al P N_T_S_
Reviewed for Code
Compliance
Universal Engineering
1B Sciences
LINDIAN
4 H WY A1A, SUITE 301
HARBOUR BEpriH,FLORIDA 32937'IPH: 321-802-3591w.abdesigngroup com
AA #: 0003325'
t
CREEKSIDE
PHASE' 2
LOT #5
PROJECT*
04321.200 025R1
MODEL.•
4EAB
"1672-ARIA„
•ARAGE SWING•:
RIGHT
PAGE: m
DETAIL'
L160 MPH EXP, C
ARCHfTECT:
STATE OF FLORIDA
MAR 19 2021
[MICHAEL C. ANDERSON
AR NO 17305
PRINT 03 17 21
DATE:
SCALE: 1/4"=1'-0"
SHEET
S 3 e 1_ '411,�,,
GABLEEND
a1
HIP ROOF X�F
ROOF WIND DESIGN PRESSURES
NET (GROSS) ASCE 7-16
ZONE 1 = 53.00 PSF (63.00)
ZONE 3 = 60.90 PSF (70.90)
ZONE 2e = 60.90 PSF (70.90)
ZONE 3e = 70.40 PSF (80.40)
ZONE 2n = 70.40 PSF (80.40)
ZONE 3r = 83.80 PSF (93.80)
ZONE 2r = 70A0 PSF (80.40)
"A"= 4'-0" END ZONE DISTANCE
BASIC WIND SPEED: 160 MPH
EXPOSURE CATEGORY: "C"
RISK CATAGORY: II
APPLICABLE INTERNAL
PRESSURE COEFFICIENT: +/- 0.18
ROOF DIAPHRAGM
FOR ASPHALT SHINGLE ROOF, USE MIN 7/16" STRUCTURAL
SHEATHING EXP 1(24/16) or 15/32" STRUCTURAL SHEATHING EXP 1
(32/16), FOR CEMENTITIOUS TILE AND METAL ROOFING, USE 15/32"
STRUCTURAL SHEATHING EXP 1 (32/16) .(SEE TABLE FOR FIELD AND
EDGE SPACING) SEE DETAIL.
ROOF SHEATHING TO GABLE END FRAME USE 8d RING SHANK GUN
NAILS @ 4" O.C. EDGEWISE 2x4 BLOCKING ALL PANEL JOINTS W/ IN 4'
OF GABLE END(.
GENERAL NOTES:
ALL AGGREGATE USED IN CONCRETE SHALL. CONFORM TO ASTM C33/C33M. MAXIMUM AGGREGATE SIZE $HALL BE 3/4".
STRUCTURAL DRAWINGS.. SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND
WOOD:ARCHITECTURAL,
MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT
PROVIDE 6%AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER
"
ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT SHOWN
NON -BEARING WC
ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE STANDARDS: FBC-R 2020, 7th EDITION
ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 3W.
ALL WOOD FOR BI
TUTLDING ALCONCREREQUIREMENTS
ACI STRUCTURAL
FOR STRUCTURALCONCRETE, TMS 402/602-16 AISI SPECIFICATION FOR THE DESIGN OF
PROVIDE CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND
CRIPPLERS,SILLS
C LD FORMED STEEL STRUCTURAL MEMBERS 2016, ASCE 7-16 AND AISC SPECIFICATIONS
DRAWINGS. SEAMS LAPPED 6 INCHES AND SEALED WITH ADHESIVE TAPE. -
ELASTICITY - 1,40
PRESSURE TREAT
A L DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND
FORM -WORK:
SHALL BE RATED
CORROBORATE T
S `ALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT,
EXCEPT
I
FORM -WORK, SHORING, AND. BRACING FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, (WIALLS,
REASON SHALL BI
WHERE A DIFFERENT DETAIL IS SHOWN.
AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI347 LATEST
W/ DOT SHALL BE
EDITION,"RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK.
CONTAINS MORE
ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE
DRAWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT
EXCLUSIONS FROM THESE PLANS:
MINIMUM NAILING(
TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE AFFECTED PART
WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION, OR OTHER NON STRUCTURAL ITEMS
OF THE WORK.
ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TORE SYRUCTURAL.DEPENDING
PROVIDE SOLID BI
. THE STRUCTURE IS DESIGNED TO BE SUPPORTING AND STABLE AFTER THE BUILDING
ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS.
SYP #2.
IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND
I'.
UNTREATED WOOl
SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS
I
WELDED WIRE MESH:
AT BEARING LOCA
DURING ERECTION. THIS .WORK INCLUDES THE ADDITION OF NECESSARY SHORING, SHEETING,
I,.
TEMPORARY BRACING, GUYS OR TIE -DOWNS.
WELDED WIRE MESH, SHALL BE ASTM At 064/A1064M, GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE
ACI TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL
W
WOOD TRU.q.
THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION
BE. SUPPORTED WITH 2" CHAIRS SPACED 3'-O"OC, EACH WAY.
TO REDESIGNED
j
REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS.
STRESS -GRADE LI
SEALED BY A PRO
DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR
REINFORCING STEEL:
TO WORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND,
REBAR SHALL BE ASTM A615A615M GRADE 40 IN CONCRETE DEFORMED BARS; REBAR SHALL BE ASTM A615
CONNECTORPLAI
GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE
MEETING THE REC
DESIGN LOADS:
W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS.
CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL
DESIGN, FABRICA'.
ROOF: LIVE LOAD FLOOR: LIVE LOAD psl
AND VERTICAL BARS SHALL LAP 6 x.BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEERS
'
STANDARDS FOR
COMMENTARY ANI
I
20 psf TOP CHORD -non-concurrent
REVIEW.
MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36"
WOOD TRUSSES.TYP.
1 0 psf BTM CHORD -non-concurrent -
#5 BAR - 30" #7 BAR - 42"
PROVIDE 36" x 36" CORNER. BARS; BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM! REBAR, SEE DETAILS
TRUSS MANUFACI
DEAD LOAD DEAD LOAD >
FOR ADDITIONAL INFORMATION.
LOCATIONS WITH
15 pef TOP CHORD " 20 psf TOP CHORD
-
INTERSECTIONS C
(7 psf w/ ASPHALT SHINGLES) (10 psf w/ No GYPCRETE
10 psf BTM CHORD 5 psf BTM CHORD
ALL VERTICAL REINFORCING BARS IN CMU CELLS SHALL BE ANCHORED IN THE FOOTING,
THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH
HURRICANE STRAI
DEAD LOAD TO RESIST WIND UPLIFT: 1 Opsf
MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE
CONTRACTOR SHE
"
BALCONY LIVE LOAD 60 psf
WALL.
TRUSSES/GIRDER.
STAIRS LIVE LOAD 40 psf
WIND:
DEAD LOAD SPEED MPH
RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL
ROOF &: FLOOR LA
(ASCE 7-16 {FBC R2020) EXPOSURE C, RISK CATEGORY II)
020) SUSECONDC,RISK CA
INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER
POSSIBLE.
DETERMINATIONS,
LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: 10psf, UNINHABITABLE ATTIC WITH LIMITED
I I
LAYOUT. SPANS &
STORAGE:20psf, HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: 30psf, BALCONIES (EXTERIOR)
DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATIO
OF EMBEDDED ITEMS
.AFFECT THE STRU
AND DECKS: 40psf, GUARDS AND HANDRAILS: 200psf, GUARD IN -FILL COMPONENTS: 50psf, PASSENGER
WITHOUT THE APPROVAL OF THE ENGINEER.
STRUCTURAL ENG
VEHICLE GARAGES: 50psf, ROOMS OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30psf, STAIRS:
PROVIDE. ENGINEE
40psf
MASONRY:
PLAN SHOWING C(
.MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENT
OF THE
LICENSED PROFE:
SHOP DRAWING REVIEW:
"SPECIFICATION MASONRY STRUCTURES" (TMS 402, BUILDING CODE REQUIREMENTS F�R
MASONRY
SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT
STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES),
AS PUBLISHED BY
THE HURRICANE S
OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY OF THE. CONTRACTOR TO VERIFY
THE MASONRY SJOINT COMMITTEE.
CONSTRUCTION SITANDARDS
COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC.
PROVIDED
ED BY THE
D
ALL BLOCK WALLS SHALL BE TWO CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK
THE TO STI
ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT.. MANUFACTURED IN CONFORMANCE WITH ASTM C-90, GRADE Pm = 2000 PSI.: BLOCK SHALL BE PLACED USING OF THE DELEGATE
ROOF/ WALL/ FLOOR DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. SHOP DRAWINGS IN THE FORM RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE AND CLADDING WI
OF REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON -TRACT DOCUMENTS) ARE.. PROHIBITED PLACING CONCRETE FOR IN -WALL COLUMNS. GROUT USED TO FILL MASONRY. CELLS SHALL COMPLY WITH ALL TRUSS TO TRI
SHEATHING WITHOUT THE EXPRESS WRITTEN PERMISSION FROM THE ENGINEER, IN ALL INSTANCES, THE CONTRACT ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28DAYS, UNLESS
DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWISE: SPECIFIED IN SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT MIX SHALL HAVE A MAXIMUM 3/8.,
FASTENER SCHEDULE WRITING BY THE ARCHITECT. COURSE AGGREGATE, AND SHALL BE PLACED W/ A SLUMP OF 8" TO 10". USE ONLY MECHANICAL VIBRATION
TO CONSOLIDATE GROUT:
FOUNDATION/ SITE PREPARATION:
NAIL REQUIREMENTS TYPE "M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT MORTAR SHALL B
SIZE HEAD LENGTH DIA. TENSILE STR. SHANK ASTM
8d RING SHANK, 2 3/8" 0.113 17Q000' RING F1667
SCREW SHANK (16-20 RINGS RSRS-01
PER INCH)
8d RING SHANK,
PNEUMATIC 2 3/8" 0.113 F1667
SCREW -NAILS I I I I
RSRS-01
E
FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE 2psf; FOOTING PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS
EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY
OF OF AT LEAST 95%OF THE SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO
MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D-1557. TREAT ALL CELLS TO BE FILLED.
SOIL FOR TERMITE PROTECTION.
FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL
THE: OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY REINFORCING.
SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE !
GEC -TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE LAP VERTICAL REBAR 6 X BAR NO..(48 BAR DIAMETERS)., U.N.O.
CONTRACTOR'S EXPENSE AND A S DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE
x
E
FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE 2psf; FOOTING PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS
EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY
OF OF AT LEAST 95%OF THE SHALL BE 3/8" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO
MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D-1557. TREAT ALL CELLS TO BE FILLED.
SOIL FOR TERMITE PROTECTION.
FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL
THE: OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO-TECHNICAL ENGINEER TO VERIFY REINFORCING.
SUCCESSFUL COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE !
GEC -TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE LAP VERTICAL REBAR 6 X BAR NO..(48 BAR DIAMETERS)., U.N.O.
CONTRACTOR'S EXPENSE AND A S DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE
x
EXTERIOR SHEATHING
MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL
STRUCTURAL STEEL:
USE 1/2" CDX OR 7/16 O S B. PLY WITH 8d RING SHANK GUN NAILS AT
BE MADE BY THE GEO-TECH ENGINEER.
4 O C AT PANEL SIDES AND 8d RING SHANK GUN NAILS 4" O.C. TOP &
O.C.
RAFTER OR TRUSS
THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY
WITH THE
BOTTOM PANEL. AND 8d RING SHANK GUN NAILS AT 6" O.C. AT
ROOF SHEATHING
CONCRETE:
SPECIFICATIONS FOR THE DE TI N
DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL
FOR BUILDINGS,
INTERMEDIATE SUPPORTS R 7 1 ZIP
SU O S O / fi Z SHEATHING SYSTEM
CO CR� ETE SHALL ACHIEVE MINI MUM 28 DAY COMPRESSIVE STREN TH A G S S FOLLOWS:
9TH EDITION, BY THE A O E MERICAN INSTITUTEOF STEEL N CONSTRUCTION. STRUCTURAL U S
EEL SHALL BE ASTM
INSTALLED PER MAN F. P
U SECS. SEE DETAIL.
1-
A36/A M F 36 36 ksi FOR ANGLES, P AND W HAP G S, PLATES, S ES. STRUCTURAL TUBING S
Y U TUBING SHALL
BE ASTM
S
-
I_
�
2500 PSI REGULAR WEIGHTFOR FOOTINGS AND SLAB -ON -GRADE
GRADE B, Fy L 46 ksi. STRUCTURAL PIPE SHALL BE ASTM 3M, GRAD
A50si.
B, TYPE E OR S, Fy =
-"- - "---
,
3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB
TUBE
35 ksi. TUBEAND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP.
SHOP.
'
ROOF SHEATHING ATTACHEMENT SPACING
0 =
z
CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO
ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307BOLTS WITH DOUBLE -NU
OTHER BOLTS SHALL BE ASTM F3125/F3125M BOLTS WITH WASHERS UNDER THE TURN
LEVELING. ALL
D ELEMENT. BOLTS
O
CONCRETE PLACEMENT. CONCRETE SLUMP SHALL NOT EXCEED 5" +1- PRIOR TO THE ADDITION OF PLASTICIZER.
ZONE 1: 8d NAILS @ 4" O.C. ON EDGE AND 6" O.C. IN FIELD
-
I
-
SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD.
ZONE 2e, 2n, 2r: 8d NAILS @ 4" O.C. ON EDGE AND 4" O.C. IN FIELD
_ _
�
m
CON CRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 316 AND ASTM C941C94M OR MEASURING, MIXING, TRANSPORTING,
qLL ANCHOR BOLTS SHALL BE GALVANIZED -
NIZED STEEL.J BOLTS ARE TO BE STEEL.
ZONE 3,3e, 3r: 8d NAILS @ 4" O.C. ON EDGE AND 4"O.C. IN FIELD
ETCl. CONCRETE TICKETS SHALL BE TIME -STAMPED CONCRETE IS BATCHED. THE. MAXIMUM TIME ALLOWED FROM WHEN
'Nit
NWATER
IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES, IF FOR ANY REASON
BUILDING LENGTH
THERE IS A DELAY IN SUCH THAT A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL
BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY
NOTE: ROOF SHEATHING THICKNESS WAS CALCULATED
ROOF SHEATHING LAYOUT
NON COMPLIANCE WITH THE ABOVE.
AND ADHERES TO ASCE 7-16
AND ENDWALL BRACING
FOR GABLE END FRAMING
REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS:
NOTE: GABLES -DROP GABLE END & (1) ADD'L DROPPED
A T FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS):
B. FOR CONCRETE EXPOSED TO EARTH AND/OR WEATHER
TRUSS 2x4 #2 SYP OUTLOOKER RAFTER W/ BLOCKING @
1-1J2"FOR #SAND SMALLER
16"O C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP
2" FOR #6 AND LARGER
BLOCKING @ 16" O.C. FIRST 4 BAYS W/ (2)12d NAILS EA.
C FOR CONCRETE NOT EXPOSED TO WEATHER
END. ATTACH ROOF SHEATHING TO RAFTERS 2/
3/4" FOR SLABS, WALLS AND JOISTS
BLOCKING PER NAILING SCHEDUL
Sd RING SHANK GUN NAILS @ 4" O.C.
TOP & BOTTOM EDGES
J
Q
7
J_
Q
Z Lu
zo
LIJ
� V
Q U
O
z
z
CO
Z D)
Lu
E1 1-1, FOR BEAM AND COLUMN PRIMARY REINFORCEMENT, TIES, STIRRUPS
C8d RING SHANK GUN NAILS
SEE "ROOF SHEATHING ATTACHMENT"
TABLE FOR FIELD SPACING
TYP. EXT. SHEATHING ATTACHMENT FOR STRUCTURAL ROOF
IEATHING
a, S
Lu
V
cc0 #8 2" DECK SCREWS @ 6" 8" O.C. MAX Co)
LU
7) EDGES & 12" O.C. MAX IN FIELD. UNTHREADED
U @J SHANK TO EXTEND BEYOND THICKNESS OF
00 SUB -FLOOR SHEATHING
N � -
v
m
TYP. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS
TYP. EXT: SHEATHING ATTACHMENT
!
FASTENER SCHED U LE
A R C H 1 T E C T S
Design
Group «�
April 21, 2021
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Ave.
Fort Pierce, FL 34982
(772)462-2172
RE: Permit #
D.R. Horton Homes
Creekside Lot 25
Response Letter
For the above listed project, the plans indicate 7/16" roof sheathing on sheet SNI.
This is an error on the plans. The correct callout shall be 19/32" sheathing thickness and
the correct reference for wind pressures is ASCE 7-16 reference.
Reviewed for Code
compince
Universal En ine
gineenng
by Sciences
Should you have any questions, please feel free to contact me.
Sincerer,
',Aihael C. Ander 21-"
Fibs $d civfcrw� #A7Z17305
2194 Hwy AIA, Suite 301 Indian Harbour Beach, FL 32937 • Phone: (321) 802-3591
www.abdesigngroup.com
e 1-
I
{'t.
Viewed for Code
Compliance eenn9
UpiverSciences
WINDOW AND
DOOR BUCK
FASTENERE
FASTENER
APPLICATION
SIZE
TYPE
SPACING
REMARKS
APPLICATION
SIZE TYPE SPACING REMARKS
_
1x2 PT FURRING T.
MASONRY iC N
COW.
CASE HARDENED
NAIL L/2 " LONG.
8" O/C
GARAGE DOOR BUCK
- ---
1/4"DIA. TAPCON MASONRY 1 1/2' EMBED., 4" END DIST,
TO MASONRY/GONG.
NO WASHER FASTENER 8" O/C 1 1/2" EDGE DIST.
SOD. AL. EXT. DOORS
CASE HARDENED COIL
'
9" O/C
WINDOW%DOOR. FASTENED
GARAGE DOOR BUCK
3/8"DIAOR
. ( ) q'
16" O/C 3/8" DIA
1x PT, SEE NOTE 6
NAIL I/2" LONG.
STAGGERED
INTO MASONRY/CONC.
TO MASONRY/CONC.
1/2" DIA. EXPANSION BOLT EMBED., VEND DIST,
24' O,C (i;2". DIA( 3" EDGE DIST.
w/ WASHER_
WINDOW BUCK
CASE HARDENED COIL
1
9"O!C
WINDOW,DOOR/FASTENED
IdETAL STRAP TO
/� �+
_ /� THIS ENGINEER
CONTACT THIS(�ENGINEER FOR SPACING:
1x PT, SEE NOTE 6.
MAIL11/2'LONG.
STAGGERED
INTO MASONRY/CON(:.
MASONRY/CONQ
NON -BEARING WOOD
pEla(UIREMENTO.
EXT. SWING DOOR
BUCK 2x PT, SEE NOTE
121 3/16"DIA.
NOiWASHER
"TAPCON"
FASTNER
18' O/C
1 1/2' EMBED, 8" END.
DIST.,
1/2""
EXPANSION
4' EMBED. 4" END
- --
1 V2" EDGE DIST.
WALL TO CONC. SLAB
Wi WASHER
BOLT
24' O/C
DIST, 3" EDGE DIST:
2x PT WINDOW BUCK
- -
n 13A.rPAF x 21/8' 9"DiC
PT TO STEEL COL,SEF
4" END. DIST., 1 112"
W/ WASHER STAGGERED
NOTE6
EDGE DIST
NOTES -
1. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS
2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO
FRAMING.SUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND / OR NOA
3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED
-
4. PAF SHALL BE HILTI X-ZF HEAVY DUTY PINS OR EQUAL SAME DIAMETER ASSPE
IFIED HEREIN
5. FASTENER SPACING FOR THE BUCKS SHALL BE THE!STRICTER REQUIREMENT
F THE NOA OR THE SPACING DETAILED ABOVE
6. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW
FRAME. EXCEPT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. 1xMEMBERS ARE NAILED AND
2x MEMBERS ARE SECURED W/ TAPCONSOR PAF TO TIE SUBSTRATE.
I
r
svHDIV 8e LOT:
CREEKSIDE
PHASE 2
LOT #25
PROJECT*
04321.200 025R1
MODEL:
4EAB
"1672-ARIA"
GARAGE SWING -
RIGHT
PAGE:
DETAILS
160 MPIJ;. C
ARCHrFECT:
STATE OF FLCRIDA
- i
MAR 19 2021
MICHAEL C. ANDERSON
AIR NO 17305
PRINT
DATE / /
03 17 21
SCALE:1/4"=1'-0' F
SIAEET
S N I