HomeMy WebLinkAboutAPPROVED, Sun-Tek Manufacturing, Inc. - Skylight glass MD-CMA NOA.pdfMIAMI-DADEIR
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE
Sun-Tek Manufacturing, Inc.
10303 General Dr.
Orlando, FL 32824
" S,-v 1, "
MIAMI-DAME COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Streel Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
►vww, m iam idade.eoWb uildi ne
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building; code.
This product is approved as described herein and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: MD-CMA Skylight.
APPROVAL DOCUMENT: Drawing No. CMA-002, titled "MD-CMA", sheets 1 and 2 of 2, prepared by
Sun-Tek Manufacturing, .Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on November
10, 2020, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance
number and the expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved" or the Product Control Seal, unless
otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it
shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #17-1023.18 and consists of this page 1, evidence submitted pages E-1, E-2, and E-3 as
well as approval document mentioned above.
The submitted documentation was reviewed by Helmy A. Makar, P.E., M.S.
y; �r NOA No. 2Q-1123.10
MIAMMADECOl1NTY Expiration Date: 0311312023
e�.� f r l z-e 74 Approval Date: 02/18/2021
Page 1
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #08-0110.06
A. DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No. CMA-002, titled "MD-CMA ", sheets I and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated 09113195 and 04125195, with no revisions, signed and sealed by
Rene J. Quiroga, P.E.
B. TESTS
1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94
along with marked -up drawings and installation diagram of Model MD -CAA Curb
Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories,
Test Report #210-2885-1, dated 10131102, signed and sealed by W. A. Davis Jr., P.E.
C. CALCULATIONS
1. Anchor calculations prepared by Product Technology Corporation on 02105103,
signed and sealed by A. Perez Maldonado, PE.
D. QUALITY ASSURANCE
1. Miami Dade Building Code Compliance Office (BCCO)
E. MATERIAL CERTIFICATIONS
L Notice of Acceptance No. 07-02IZ01 issued to General Electric Plastics for their
"Leman Sheet Products". approved 05125107, expiring on 07117108.
F. STATEMENT
L Code compliance letter issued by Product Technology Corporation on 02106103,
signed and sealed by A. Perez Maldonado
(Evidence Submitted under NOA # 03-0401.07)
G. OTHERS
1. Notice of Acceptance No. 03-0401.07, issued to Sun- Tek Manufacturing, Inc.,
approved on 10109103 and expiring on 03113108.
2. No change letter issued by Sun-Tek Manufacturing, Inc., dated 01102108, signed by
James Feudner.
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #11-0601.04
A. DRAWINGS
1. Drawing No. CMA-002, titled "MD-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr.,
P.E., on May 08, 2012. /
Iftelmy A. Makar, P.E., M.S.
Pro -duct Control Section Supervisor
NOA No. 20-1123.10
Expiration Date: 03/13/2023
Approval Date: 02/18/2021
E-1
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
B. TESTS
1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94 along with
marked -up drawings and installation diagram of Model MD-CMA Curb Mount
Plastic Dome Skylight, prepared by National Certified Testing Lab., Report
NCTL-210-3859-1, dated 03104113, signed & sealed by Gerard J. Ferrara,P.E.
C. CALCULATIONS
1. Anchor calculations prepared by J & L Wells Consulting LLC, 19 pages, dated
0311912013, signed and sealed by James D. Wells, Jr., P.E.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENT
1. Florida Building Code, 2010 Edition, compliance letter prepared by J & L Wells
Consulting LLC, dated 0412512012, signed and sealed by James D. Wells, Jr., P. E.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #15-0513.05
A. DRAWINGS
1. Drawing #CMA-002, titled "AID -CAA' , sheets 1 and 2 of 2, prepared by Sun- Tek
Manufacturing, Inc., dated 05109111, signed & sealed by James D. Wells, Jr., P.E., on
0510811Z
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENT
1. FBC, 2014 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated
0510512015, signed and sealed by James D. Wells, Jr., P.E.
f
i lmy A. Makar, P.E., M.S.
Prodir& Control Section Supervisor
NOA No. 20-1123.10
Expiration Date: 03/13/2023
Approval Date: 02/18/2021
E -2
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #17-1023.18
A. DRAWINGS
1. Drawing No. CMA-002, titled "MD-CMA ", sheets I and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr.,
P.E., on October 06, 2017.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENT
1. Florida Building Code, 2017 Edition, compliance letter prepared by J & L Wells
Consulting LLC, dated 1010612017, signed and sealed by James D. Wells, Jr., P. E.
5. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. CMA-002, titled "MD-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr.,
P.E., on November 10, 2020.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENT
1. Florida Building Code, 2020 Edition, compliance letter prepared by J & L Wells
Consulting LLC, dated 11/1012020, signed and sealed by James D. Wells, Jr., P.E.
L, 6 1). LIL /I/-
elmy A. Makar, P.E., M.S.
Product Control Section Supervisor
NOA No. 20-1123.10
Expiration Date: 03/13/2023
Approval Date: 02/18/2021
E -3
ngineer• of Record
James D. Wells, Jr.,P.E.
Professionol Engineer No. 53616
SYM
�'—!! l-�— 3.0000 (�— 10.625-1
DIMENSIONS :O
=-AS-EVER I_OCA1
m rAS I-ENERS
jG CURB
6 RIVETS
'._:LY 1 D ALUM
RIVET L:ICAT T17n$
rASTENER SCHEDULE SKYLIGHT TO
110 X 2 PAN HEAD SHEET VCTAL
PER lo, PER SHORT
S. SIDE
1--13.62 s --
—27.256 MAX.
FASTENER SCHEDULE CURT;
TO DECK #10 X 3- DECK
�SCREWS
PER LONG PER SHORT
-- SIDE SIDE --
J&l. Wells Consulting LLC
1453 Arbitus Circle
Oviedo. FI. 32765
(407)496-5489
Certificote of Authorizotion
N n ' 17 1 r,, 7
PRODULT NAVE- M D — C IV1A
stcow Otm%c ICOKiAMr0s1
SIi-rOW SL.A/p C[rrRfrl
w•LKI•t A1H ttPrO ,
tCO.QPIPOs)
0[c0 InNc sn.7ra
Atw rMOYc�utuOniuO
� rNi.OtD Cprr4w5
.taro - .rw ,IS A— tA.rL
1 q/yan sict x
Rto A f P�. Ws om .w� S-IEr Yt,& sd[r
1.) 04 Low 5mrA (3) 04 SMRI $;R,
no . r D[c• SL4DA
t•) on ." 40L
to a vat. sar
DWG.N: CMA--002
Owe's DoK .0T0 mycAfte"rt
IM rq{tp1MWL $r.ELI
P"Lw VAL11M.
S-uri(LD L4R0Llpr r
K LC A "J.
n stt• (w as" eras ..i"l w cc
SotfltCut t0 W.Mm
s• M*PAPA At tmf,%i aDOIr
Or AWWa r0 401 iU7rAtt
StIR N[D P OWM N
NOTE:(uVM.OM 0✓ Dim cows.)
(1) ALL ROor-ING DETAILS SHALL COMPLY WITH
CHAPTER 15 OF THE 2020 FLORIDA BUILDING CODE --
(2) 4' LtINIAILIM OISTANCC rROFd ANGLE LIP TO ROOF
SURFACE is Fort SHINGLE. OR B.U.R. WITHOUT
INSULATION. rOR INSULATION AND TILE ROOT ADD
TILE HEIGHT AND INS1 ATiON THICKNESS TO 4-
LIINMA HEIGHT.
(3) ANCHORS TO BE MADE Or N0%-CORROSNE MATERIAL.
COMPATABLE WITH ALUMINLnA.
RIVET SCHEDULE DECO
TO POMAR13ONATE 3/1C
PER LONG PER SI
SIDE SIDE
wA rw. •.v
may AM osReeo�.r
Lo WA4:oL0a. e.
asq 003-
LU
In
tY r4
FOCS 10 %tk%. LIArEAnt_ a. onus I A qww 0 In
0111L11Tlrrrr"
�p,V ID W£z�
*� 1) 61-_�.A �* _
ATE OF L�
SUN-TEI( MANUFACTURING, INC.
10303 GLNCRAL DRIVE ORLANDO. FL 32824
ncineer of Record
James D. Wells, Jr.,P.E.
Professional Engineer No. 53616
J&L Wells Consulting LLC
1453 Arbitus Circle
Oviedo, Fl. 32765
{407)496-5489
Certificate of Authorization
No. 27162
DESIGN PRESSURE RATING
+- 6Q PSF
#10 x 2' SCREW PPH LARGE MISSLE IMPACT RESISTANCE
(4) ON LONG SIDE& (3) 0.4 SHORT SIDE
MINIMUM ENBEDMENT
DECO RING STI-275
.060 THICK ALUMINUM.
6063 T6 MITRE
AND WELDED CORNERS
arr- 30
4" MINIMUM
SE. NOTE Jf2
s INGLES (2) V.1
2x SYP (SG 0.55) CURB HEIGHT
TO BE SJFFICIENT TO MAINTAIN
4" MINIMUM AT LOWEST POINT
OF PRAVE TO ROOF SURFACE
SUPPLIED BY OTHERS AN
(APPROVED BY DADE COUNTY)
4ER LINER .030 polycoroonot
(Pogrom Pol2un.
Sheffield Mokrolon or
Sobic Lexon 9034)
FINISHED WALL MATERIAL
BY OTHERS ( APPROVED
DADE COUNTY)
5-1/2." DOME RISE
����'' �,�� E a SE''•=sue'-;
Q
�* 5 616
Jtaf
TATE OF ,C r
'ffl; /� /ONAV";
_ OUTER DOME .070 POLYCARBONATE
(Pogrom Polsun.
Sheffield Mokrolon or
Sabic Lexon 9034)
- S1LiCONE
AIR =gUJED INSULATED SPACE
#10 x 3" DECK SCREW
(4) ON LONG SIDE
(3) ON SHORT SIDE _
MINIMUM ENBEDMENT 5 8"
NOTE:
(1) ALL ROOFING DETAILS SHALL COMPLY WITH
CHAPTER 15 OF THE 2020 FLORIDA BUILDING CODE.
(2) a" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF
SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT
INSULATION. FOR INSULATION AND TILE ROOF ADD
TILE HEIGHT AND INSULATION THICKNESS TO 4'
MINIMUM HEIGHT.
(3) ANCHORS TO BE MADE Or NON -CORROSIVE MATERIAL, ROOF DECK
COMPATABLE WITH ALUMINUM.
STS-•1000 SEALANT (CONTNNOUS)
DW11.0- CMA-002
BEDDING (CONTINUOUS)
BUTYL RUBBER SEALANT
BETWEEN SKYLIGHT
AND CURB (continuous)
`SHIMO EA. ANCHOR (TYP)
WITH LOAD BEARING SHIM
0.500 MAX.
3/ 16" RIVET
2 /LONG SIDE
1 /SHORT SIDE
FLA51-11NO BY OTHERS IN
ACCORDANCE WITH NRCA
0
000
PRooucT NAZIt
— - N � - C MA SUN TEK ViA t;FAC'fURI NG, INC.
1""SI, _- . .>JOnT�- ti;l I DATF!S 09 1 i SCAI_r- ---- DWG NoCM A 002 10303 MERAL DMNT oRLMn0. FL 32824