Loading...
HomeMy WebLinkAboutAPPROVED, Sun-Tek Manufacturing, Inc. - Skylight glass MD-CMA NOA.pdfMIAMI-DADEIR DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE Sun-Tek Manufacturing, Inc. 10303 General Dr. Orlando, FL 32824 " S,-v 1, " MIAMI-DAME COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Streel Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 ►vww, m iam idade.eoWb uildi ne SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building; code. This product is approved as described herein and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: MD-CMA Skylight. APPROVAL DOCUMENT: Drawing No. CMA-002, titled "MD-CMA", sheets 1 and 2 of 2, prepared by Sun-Tek Manufacturing, .Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on November 10, 2020, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturers name or logo, city, state and following statement: "Miami -Dade County Product Control Approved" or the Product Control Seal, unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #17-1023.18 and consists of this page 1, evidence submitted pages E-1, E-2, and E-3 as well as approval document mentioned above. The submitted documentation was reviewed by Helmy A. Makar, P.E., M.S. y; �r NOA No. 2Q-1123.10 MIAMMADECOl1NTY Expiration Date: 0311312023 e�.� f r l z-e 74 Approval Date: 02/18/2021 Page 1 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #08-0110.06 A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. CMA-002, titled "MD-CMA ", sheets I and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated 09113195 and 04125195, with no revisions, signed and sealed by Rene J. Quiroga, P.E. B. TESTS 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94 along with marked -up drawings and installation diagram of Model MD -CAA Curb Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories, Test Report #210-2885-1, dated 10131102, signed and sealed by W. A. Davis Jr., P.E. C. CALCULATIONS 1. Anchor calculations prepared by Product Technology Corporation on 02105103, signed and sealed by A. Perez Maldonado, PE. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO) E. MATERIAL CERTIFICATIONS L Notice of Acceptance No. 07-02IZ01 issued to General Electric Plastics for their "Leman Sheet Products". approved 05125107, expiring on 07117108. F. STATEMENT L Code compliance letter issued by Product Technology Corporation on 02106103, signed and sealed by A. Perez Maldonado (Evidence Submitted under NOA # 03-0401.07) G. OTHERS 1. Notice of Acceptance No. 03-0401.07, issued to Sun- Tek Manufacturing, Inc., approved on 10109103 and expiring on 03113108. 2. No change letter issued by Sun-Tek Manufacturing, Inc., dated 01102108, signed by James Feudner. 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #11-0601.04 A. DRAWINGS 1. Drawing No. CMA-002, titled "MD-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on May 08, 2012. / Iftelmy A. Makar, P.E., M.S. Pro -duct Control Section Supervisor NOA No. 20-1123.10 Expiration Date: 03/13/2023 Approval Date: 02/18/2021 E-1 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED B. TESTS 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94 along with marked -up drawings and installation diagram of Model MD-CMA Curb Mount Plastic Dome Skylight, prepared by National Certified Testing Lab., Report NCTL-210-3859-1, dated 03104113, signed & sealed by Gerard J. Ferrara,P.E. C. CALCULATIONS 1. Anchor calculations prepared by J & L Wells Consulting LLC, 19 pages, dated 0311912013, signed and sealed by James D. Wells, Jr., P.E. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Florida Building Code, 2010 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated 0412512012, signed and sealed by James D. Wells, Jr., P. E. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #15-0513.05 A. DRAWINGS 1. Drawing #CMA-002, titled "AID -CAA' , sheets 1 and 2 of 2, prepared by Sun- Tek Manufacturing, Inc., dated 05109111, signed & sealed by James D. Wells, Jr., P.E., on 0510811Z B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. FBC, 2014 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., P.E. f i lmy A. Makar, P.E., M.S. Prodir& Control Section Supervisor NOA No. 20-1123.10 Expiration Date: 03/13/2023 Approval Date: 02/18/2021 E -2 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 4. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #17-1023.18 A. DRAWINGS 1. Drawing No. CMA-002, titled "MD-CMA ", sheets I and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on October 06, 2017. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Florida Building Code, 2017 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated 1010612017, signed and sealed by James D. Wells, Jr., P. E. 5. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. CMA-002, titled "MD-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on November 10, 2020. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Florida Building Code, 2020 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated 11/1012020, signed and sealed by James D. Wells, Jr., P.E. L, 6 1). LIL /I/- elmy A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 20-1123.10 Expiration Date: 03/13/2023 Approval Date: 02/18/2021 E -3 ngineer• of Record James D. Wells, Jr.,P.E. Professionol Engineer No. 53616 SYM �'—!! l-�— 3.0000 (�— 10.625-1 DIMENSIONS :O =-AS-EVER I_OCA1 m rAS I-ENERS jG CURB 6 RIVETS '._:LY 1 D ALUM RIVET L:ICAT T17n$ rASTENER SCHEDULE SKYLIGHT TO 110 X 2 PAN HEAD SHEET VCTAL PER lo, PER SHORT S. SIDE 1--13.62 s -- —27.256 MAX. FASTENER SCHEDULE CURT; TO DECK #10 X 3- DECK �SCREWS PER LONG PER SHORT -- SIDE SIDE -- J&l. Wells Consulting LLC 1453 Arbitus Circle Oviedo. FI. 32765 (407)496-5489 Certificote of Authorizotion N n ' 17 1 r,, 7 PRODULT NAVE- M D — C IV1A stcow Otm%c ICOKiAMr0s1 SIi-rOW SL.A/p C[rrRfrl w•LKI•t A1H ttPrO , tCO.QPIPOs) 0[c0 InNc sn.7ra Atw rMOYc�utuOniuO � rNi.OtD Cprr4w5 .taro - .rw ,IS A— tA.rL 1 q/yan sict x Rto A f P�. Ws om .w� S-IEr Yt,& sd[r 1.) 04 Low 5mrA (3) 04 SMRI $;R, no . r D[c• SL4DA t•) on ." 40L to a vat. sar DWG.N: CMA--002 Owe's DoK .0T0 mycAfte"rt IM rq{tp1MWL $r.ELI P"Lw VAL11M. S-uri(LD L4R0Llpr r K LC A "J. n stt• (w as" eras ..i"l w cc SotfltCut t0 W.Mm s• M*PAPA At tmf,%i aDOIr Or AWWa r0 401 iU7rAtt StIR N[D P OWM N NOTE:(uVM.OM 0✓ Dim cows.) (1) ALL ROor-ING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE 2020 FLORIDA BUILDING CODE -- (2) 4' LtINIAILIM OISTANCC rROFd ANGLE LIP TO ROOF SURFACE is Fort SHINGLE. OR B.U.R. WITHOUT INSULATION. rOR INSULATION AND TILE ROOT ADD TILE HEIGHT AND INS1 ATiON THICKNESS TO 4- LIINMA HEIGHT. (3) ANCHORS TO BE MADE Or N0%-CORROSNE MATERIAL. COMPATABLE WITH ALUMINLnA. RIVET SCHEDULE DECO TO POMAR13ONATE 3/1C PER LONG PER SI SIDE SIDE wA rw. •.v may AM osReeo�.r Lo WA4:oL0a. e. asq 003- LU In tY r4 FOCS 10 %tk%. LIArEAnt_ a. onus I A qww 0 In 0111L11Tlrrrr" �p,V ID W£z� *� 1) 61-_�.A �* _ ATE OF L� SUN-TEI( MANUFACTURING, INC. 10303 GLNCRAL DRIVE ORLANDO. FL 32824 ­ncineer of Record James D. Wells, Jr.,P.E. Professional Engineer No. 53616 J&L Wells Consulting LLC 1453 Arbitus Circle Oviedo, Fl. 32765 {407)496-5489 Certificate of Authorization No. 27162 DESIGN PRESSURE RATING +- 6Q PSF #10 x 2' SCREW PPH LARGE MISSLE IMPACT RESISTANCE (4) ON LONG SIDE& (3) 0.4 SHORT SIDE MINIMUM ENBEDMENT DECO RING STI-275 .060 THICK ALUMINUM. 6063 T6 MITRE AND WELDED CORNERS arr- 30 4" MINIMUM SE. NOTE Jf2 s INGLES (2) V.1 2x SYP (SG 0.55) CURB HEIGHT TO BE SJFFICIENT TO MAINTAIN 4" MINIMUM AT LOWEST POINT OF PRAVE TO ROOF SURFACE SUPPLIED BY OTHERS AN (APPROVED BY DADE COUNTY) 4ER LINER .030 polycoroonot (Pogrom Pol2un. Sheffield Mokrolon or Sobic Lexon 9034) FINISHED WALL MATERIAL BY OTHERS ( APPROVED DADE COUNTY) 5-1/2." DOME RISE ����'' �,�� E a SE''•=sue'-; Q �* 5 616 Jtaf TATE OF ,C r 'ffl; /� /ONAV"; _ OUTER DOME .070 POLYCARBONATE (Pogrom Polsun. Sheffield Mokrolon or Sabic Lexon 9034) - S1LiCONE AIR =gUJED INSULATED SPACE #10 x 3" DECK SCREW (4) ON LONG SIDE (3) ON SHORT SIDE _ MINIMUM ENBEDMENT 5 8" NOTE: (1) ALL ROOFING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE 2020 FLORIDA BUILDING CODE. (2) a" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT INSULATION. FOR INSULATION AND TILE ROOF ADD TILE HEIGHT AND INSULATION THICKNESS TO 4' MINIMUM HEIGHT. (3) ANCHORS TO BE MADE Or NON -CORROSIVE MATERIAL, ROOF DECK COMPATABLE WITH ALUMINUM. STS-•1000 SEALANT (CONTNNOUS) DW11.0- CMA-002 BEDDING (CONTINUOUS) BUTYL RUBBER SEALANT BETWEEN SKYLIGHT AND CURB (continuous) `SHIMO EA. ANCHOR (TYP) WITH LOAD BEARING SHIM 0.500 MAX. 3/ 16" RIVET 2 /LONG SIDE 1 /SHORT SIDE FLA51-11NO BY OTHERS IN ACCORDANCE WITH NRCA 0 000 PRooucT NAZIt — - N � - C MA SUN TEK ViA t;FAC'fURI NG, INC. 1""SI, _- . .>JOnT�- ti;l I DATF!S 09 1 i SCAI_r- ---- DWG NoCM A 002 10303 MERAL DMNT oRLMn0. FL 32824