HomeMy WebLinkAboutFinal Termite Planning & Development Services
- = Building &Code Regulation Division
COUNTY2300 Virginia Ave
• R 1 0 a Fort Pierce, FL 34982
772-462-2172 Fax 772-462-6443
CERTIFICATE OF TERMITE TREATMENT
CONSTRUCTION SOIL TREATMENT
PERMIT #: 2010-0538 JOB ADDRESS: 6507 SPANISH LAKES BLVD FORT PIERCE,FL 34951-2819
BUILDER/CONTRACTOR: WYNNE DEVELOPMENT
PEST CONTROL CONTRACTOR: EVICT-A-BUG TERMITE&PEST CONTROL INC.
PEST CONTROL LICENSE #: JB175775
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: 325 LF Chemicals used: DOMINION 2L
Percentage of solution: .05% Total gallons used: 40
Date of Treatment: 04-22-21 Time of Treatment: 1:37
Footing Slab
1st Treatment 1st Treatment
Re-Treat Re-Treat
Driveway Pools
1st Treatment 1st Treatment
Re-Treat Re-Treat
Other xxxxx Perimeter for Final Inspection
1st Treatment
ellyRe-Treat PAUL C LUGARA JR DDate:20118110b1Y14AUL 1806 04,00'RAJR 07-15-21
Signature of Exterminator Date
Note: There must be a completed form for each required treatment or re-treatment and this form must be on the job
site to be picked up by the inspector at time of each inspection or the scheduled inspection will fail and a re-inspection
fee charged.
FBC 104.2.E Certificate of Protective Treatment for prevention of termites A weather resistant jobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment is completed,
providing a copy for the person the permit is issued to and another copy for the building permit files. The Treatment
Certificate shall pro vide the product used, identity of the applicator, time and date of the treatment, site location, area
treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of
protective treatment. If the soil chemical barrier method for termite prevention is used, final exterior treatment shall
be completed prior to final building approval.
St Lucie County requires for the final inspection for CO, a Permanent Sticker to be placed on
the electrical panel box cover, listing all the treatments and dates of applications.
Revised 7/24/2014