Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETSM go �CCC� ST. LUCIE �jORKS Lj ° . . . ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B,C 12,8.4,8,6,7. Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B,D 1A4,5,8.7 Concrete or Clay rile A, B, D, E Metal Roofs A, B, D 1,2,%4,5,6,7' Wood Shingles and Shakes A, B, D L2,4A6.7 Other As Applicable 1A%4A%7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2, From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE ARKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA" ) System Manufacturer: POLYGLASS Product Approval No.: FL#1654.1 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: _ Zone 2: _Zone 3: Max. Design Pressure, from the specific product approval system: -90 W-209 Deck: Type: PLYWOOD Gauge Thickness: 518„ Slope: 1/4"/12 Anchor/Base Sheet & No. df Ply(s): 1 Anchor/Base Sheet Fastener/Bonding Material: ELASTOBASE SELF ADHERED Insulation Base Layer: N/A Base lnsultation Size and Thickness: N/A Base Insulation Fastener/Bonding Material: N/A Top Insulation Layer: N/A Top Insulation Size and Thickness: N/A Top insulation Fastener/Bonding Material: N/A Base Sheet(s) & No. of Ply(s): N/A Base Sheet Fastener/Bonding Material: N/A Ply Sheet(s)' & No. of Ply(s): APP SMOOTH TORCH Ply Sheet Fastener/Bonding Material: APP TORCH Top Ply: APP GRANULATED WHITE MODIFIED Top Ply Fastener/Bonding Material: APP TORCH APPLIED Surfacing: WA Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_" oc @ Lap, # Rows—'0 _ ac ' Zone 1:_" oc @ Lap, # Rows _ ®_ oo Zone 2:_" oc @ Lap, If Rows _ ®_ oo Zone 3:_" oc @ Lap, If Rows— ® _ oo Number of Fasteners Per Insulation Board: Zone 1':—Zone 1:—Zone 2:_Zone 3:_ Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counter6ashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16., ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof system Manufacturer: OWENS CONRING DURATION Notice of Acceptance Number: FL#10674.1 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-74_Zone 2e:-74_Zone 2n-108 one 2rr108 one 3e:--1KZone 3r: -126 Deck Type: PLYWOOD Type Undedayment I APOC Sop FELT(2 PLY) N0h16-1109.03 Roof Sbpe: 3 1p Insulation: Fire Barrier: - Ridge Ventilation? Fastener Type & Spacing: IV FIELD I V' PERIMETER, So RINGSHANK NAILS Adhesive Type: . Type Cep Sheet Mean RooPHeight: -t5' FT I Roof Covering: SHINGLES Type 8 Sim Drip 2"x2" FArm ST. LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mrvalues are greater than or equal to the M,Valuea, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: _x1 =_)- Mg, _=M,r_ Product Approval M, (Zone 2e: _x1_= I- Mg' _=M,=_ Product Approval Mr (Zone 2n:^x 1_= _)_11119;_=M._ Product Approval Mf (Zone 2r: _x 1_= _)-Mg:_=M,._ Product Approval Mr (Zone 3e: _x1_= _ I-Mg_=Mse_ Product Approval Mr (Zone 3r: 5 x1_= _J- MID: _=M,ffi_ Product Approval M, Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (M,) From Table Below- Product ADDrovaI Mr_ M, required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25' NY 40' 2:12 34.4 36.5 38.2 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 25.9 27.1 28.2 30.0 -Must be used in conjunction with a list of moment based tile systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the F'values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: x L_=x W:= -W: cos r_-Fa Product Approval F (Zone 2e:_xL =x W:= )-W: cos =Fa Product Approval F' (Zone 2n:_xL xW:=-W:_cos r Fa" Product Approval F' (Zone 2r._x LxW:=-W:cos r=F,r,_ Product Approval F' (Zone 3e: xL=xW:=_)-W: cos r=Fne Product Approval F' (Zone 3r: _x L =u W:=_� -W: Cos r F,s, Product Approval F' Where to Obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site RDof Slope B Job Site Aerodynamic Multiplier Product Approval Restoring Moment due to Gravity Mr Product Approval Attachm ent Resistance Mr Product Approval Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submitted to the building official at the time of permit application.