Loading...
HomeMy WebLinkAboutNOA ROOF UNDERLAYMENT 210-2 --0 s'3 REVIEWED FOR MEMO 1 etc. CODE ®COMPLIANCE Certificate of Authorization#32455 ST. LUCIE COUNTY 353 Christian Street, Unit#13 ®CC �� Oxford,CT 06478 (203)262-9245 ENGINEER EVALUATE TEST � CONSULT REPORTEVALUATION GAF Evaluation Report 01506.04.08-1121 1Campus Drive File COPY FL10626-R21 Parsippany, NJ 07054 lAA Date of Issuance:04/25/2008 (800)766-3411 Revision 21:04/14/2021 SCOPE: This.Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for use of the product under the Florida Building Code and Florida Building Code,Residential Volume. The products described herein have been evaluated for compliance with the 7th Edition(2020) Florida Building Code sections noted herein. DESCRIPTION: GAF Roof Underlayments for,use in FBC non..-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s)changes,the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: ac��nrp�, RobertJ.M.Nieminen P.E. = S'"`. r4LL � � ...,'F: ;94,?;: The facsimile seal appearing was authorized by Robert Nieminen,P.E.on 04/14/2021.This does not serve as an Florida Registration No.59166,Florida DCAANE1983 : ilk�e{`: electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E.does not have, nor will acquire,a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 02019 NEMO ETC,LLC ONEMOletc. ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: GAF Roof Underlayments,as produced by GAF,have demonstrated compliance with the following sections of the 7th Edition(2020)Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. 2. STANDARDS: Section, Pro a Standard Year 1504.3.1 Wind resistance FM 4474 2011 1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015 R905.1.1,R905.2.8.2 1507.1.1.1(2&3,Exception), Tear Strength ASTM D4533 2015 1507.1.1.1(5)/R905.1.1.1(2&3, Exception),R905.1.1.1(5) 1507.1.1.1(2&3,Exception), Tensile strength ASTM D5035 2011 1507.1.1.1(5)/R905.1.1.1(2&3, Exception),R905.1.1.1(5) 1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1507.1.1/R905.1.1 Material standard ASTM D6757 2016 1507.3.3,R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018 1507.11.2 Material standard ASTM D6164 2011 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity, Examination Reference Date ERD(TST 6049) ASTM D1623&FRSA/TRI(Slippage) G34150.08.11 11/14/2011 ERD(TST 6049) ASTM D6164(GA) G40630.01.14-2B 01/07/2014 ERD(TST 6049) ASTM D6164(GA) G46160.09.14-3A 09/09/2014 ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-3 03/01/2017 ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-4 03/01/2017 ERD(TST 6049) ASTM D1970(GA) GAF-SC13285.03.17-1 03/08/2017 ERD(TST6049) ASTM D1970(IN) GAF-SC16440.12.17 12/31/2017 Intertek(TST 1558) ASTM D4869(Dadra,India) F8549.02-106-18 11/08/2016 NEMO(TST 6049) Physical Properties(ON) 4q-GAF-I9-SSMBB-03.A 05/13/2019 NEMO(TST6049) ASTM D1970 4j-FTS-20-SSUDL-01.A 12/01/2020 NEMO(TST 6049) ASTM D4798,TAS 103 4j-GAF-2I-SSUDL-02.A 03/15/2021 PRI(TST 5878) ASTM D1970(IN) GAF-324-02-01 11/30/2011 PRI(TST 5878) ASTM D226(OK) GAF-339-02-01 03/13/2012 PRI(TST 5878) ASTM D4798(NC) GAF-349-02-01 07/03/2012 PRI(TST 5878) Wind Uplift GAF-434-02-01 09/16/2013 PRI(TST 5878) Wind Uplift GAF-434-02-03 09/16/2013 PRI(TST 5878) Wind Uplift GAF-434-02-04 09/16/2013 PRI(TST 5878) ASTM D4533(various) GAF-818-02-01 12/05/2017 PRI TST 5878 ASTM D1970 AL MSA-047-02-01 04 11 2018 PRI(TST 5878) ASTM D4533(LA) GAF-826-02-01 06/4/2018 PRI(TST 5878) ASTM D4533(Dadra,India) GAF-847-02-01 06/4/2018 PRI(TST 5878) ASTM D4533(Dadra,India) GAF-914-02-01 04/10/2019 PRI(TST 5878) ASTM D4533,D5035(VA) 376T0012 07/15/2019 PRI(TST 5878) ASTM D4533(Umerkui Kilvani,India) 376T0018 07/31/2019 PRI(TST 5878) ASTM D4533(Parzai,India) 376T0018 07/31/2019 PRI(TST 5878) ASTM D1970(AR) 376T0032 10/22/2019 MEMO ETC,LLC Evaluation ort 01506.04.08-R21 Report Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R21 GAF Roof Underlayments Revision 21:04/14/2021 Page 2 of 8 i OMEMO I etc. Enti Examination Reference Date PRI(TST 5878) ASTM D226(S-CA) 376T0054 02/18/2020 PRI(TST 5878) ASTM D5035(various) 376TO103 09/11/2020 PRI(TST 5878) ASTM D4533,D5035(Rajasthan,India) 376T0111 12/22/2020 UL(TST 1740) ASTM D6757(TX) 02NK22569 06/04/2002 UL(TST 1740) ASTM D6757(NC) 10NK11990 05/18/2011 NEMO ETC Traceability FBC Cross-Listing 04/22/2020 NEW Traceability FBC Cross-Listing 04/08/2021 UL,LLC(QUA 9625) Quality Control Service Confirmation 03/23/2021 UL,LLC(QUA 9625) Quality Control Service Confirmation(AL) 05/04/2020 UL,LLC(QUA 9625) Quality Control Florida BCIS Current 4. •••• DESCRIPTION: ;Product Material Standard Plant(s) 4.1 GAF Extended Dry-In Membrane ASTM D1970 Langley,BC Canada Liberty`"°SBS Self-Adhering Base/Ply Mt.Vernon,IN 4.2 Sheet ASTM D1970 Savannah,GA 4.3 StormGuard®Film Surfaced Leak Barrier ASTM D1970 Mt.Vernon,Savannah,GA Arkadelphia,AR 4.4 WeatherWatch°Mineral Surfaced Leak ASTM D1970 Mt.Vernon,IN Barrier Savannah,GA Tuscaloosa,AL Deck-ArmorTM Premium Breathable Roof 1507.1.1.1(2&3,Exception)/ 4.5 Deck Protection R905.1.1.1(2&3,Exception) Dadra,India 1507.1.1.1(2&3,Exception), Dadra,India 4.6 FeltBuster®High-Traction Synthetic 1507.1.1.1(5)/R905.1.1.1(2&3, Rajasthan,India Roofing Felt Exception),R905.1.1.1(5) Richmond,VA Spartanburg,SC g Type II(Table 1) Pryor,OK 4.7 Shin le-Mate®Roof Deck Protection ASTM D226, Shafter,CA 1507.1.1.1(2&3,Exception)/ 4.8 StormSafeTM Anchor Sheet R905.1.1.1(2&3,Exception) North Bay,ON Dadra,India 4.9 Tiger PawTM Roof Deck Protection 1507.1.1.1(2&3,Exception)/ Parzai,India R905.1.1.1(2&3,Exception) Umerkui Kilvani,India 4.10 VersaShield®Fire-Resistant Roof Deck ASTM D6757 Conover,NC Protection 4.11 Ruberoid®Mop Granule ASTM D6164 Savannah,GA FRSA/TRI09-18 4.12 Ruberoid®Mop Granule FR ASTM D6164 Savannah,GA FRSA/TRI09-18 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions (i.e., Broward and Miami- Dade Counties). NEMO ETC,LLC Evaluation Report 01506.04.08-1121 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1121 GAF Roof Underlayments Revision 21:04/24/2021 Page 3 of 8 ONEMOjetc. 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBCSection: 1507.2 150Z3 1507.4 and 150Z5 150Z7 1507.8 and 1507.9 Asphalt 'Clay and Concrete Tile Metal Slate or Wood Underlayment Mechanical Adhesive- Slate-Type Shingles Attach Set Panels Shingles Shingles Shakes Shingles Yes Yes GAF Extended Dry-In Membrane Yes No No Yes Yes Yes (Jointstrips, (joint strips, 1507.1.1.3/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Yes Yes Liberty'SBS Self-AdheringOoint Base/Ply Sheet Yes No No No No No it1.3/ 13 s07.1. 50�1.1. / R905.1.1.3) R905.1.1.3) Yes Yes StormGuard®Film Surfaced Leak (joint strips, Goint Yes No No Yes Yes Yes 13 1507.1.13/ Barrier 507.1.1. / R905.1.1.3) R905.1.1.3) Yes Yes WeatherWatch®Mineral SurfacedGoint strips, Goint strips, Leak Barrier Yes No No No No No 1507.1.13/ 1507.1.1.3/ R905.1.1.3) R905.1.1.3) Deck-Armor""Premium Breathable Yes No No Yes Yes Yes No No Roof Deck Protection FeltBuster®High-Traction Yes No No No No No No No Synthetic Roofing Felt Shingle-Mate®Roof Deck Yes No No No No No No No Protection Tiger Paw'"Roof Deck Protection Yes No No Yes Yes Yes No No VersaShield"Fire-Resistant Roof Yes No No No No No No No Deck Protection Yes Yes Ruberoid®Mop Granule No (Cap Sheet in (Cap Sheet in No No No No No 2-ply system) 2-ply system) See 5.6.1 Yes Yes Ruberoid®Mop Granule FR No (Cap Sheet in (Cap Sheet in No No No No No 2-ply system) 2-ply system) See 5.6.1 5.6.1 Adhesive-set is limited to use of following underlayment/tile-adhesive combinations. TABLE 1A:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS' Underlayment Adhesive Florida Product Approval Ruberoid®Mop Granule;Ruberoid®Mop Granule FR Dupont"Tile Bond'"'Roof Tile Adhesive" FL22525 1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC,LLC Evaluation Report 01506.04.08-R21 Certificate of Authorization#32455 7T11 EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-11121 GAF Roof Underlayments Revision 21:04/14/2021 Page 4 of 8 OMEMO etc. 5.7 Allowable Substrates: TABLE 2 SUBSTRATE OPTIONSfOR ADHEREDUNDERLAYMENTS Underlayment Application Primer Substrates GAF Extended Dry-In Membrane self-adhering None plywood Libertr SBS Self-Adhering Base/Ply Sheet StormGuard®Film Surfaced Leak Barrier self-adhering (Optional) plywood ASTM D41 Weather Watch®Mineral Surfaced Leak Barrier Liberty'"'SBS Self-Adhering Base/Ply Sheet StormGuard®Film Surfaced Leak Barrier self-adhering None ASTM D226 felt,Type II Weather Watch®Mineral Surfaced Leak Barrier LibertyTM'SBS Self-Adhering Base/Ply Sheet StormGuard®Film Surfaced Leak Barrier self-adhering ASTM D41 metal(flashing metal,valley metal, etc.) Weather Watch®Mineral Surfaced Leak Barrier Ruberoid®Mop Granule hot asphalt ASTM D41 structural concrete Ruberoid®Mop Granule FR Ruberoid®Mop Granule GAFGLAS®#80 UltimaT1 Base Sheet hot asphalt None Ruberoid®Mop Granule FR or Ruberoid®20 Smooth 5.8 Attachment Limitations: 5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not less than FBC 1507.1.1 or R905.1.1. 5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions,but—for mechanically attached base sheets-not less than: • FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1(for Two-Ply Asphalt Applied Hot Mop Underlayment) or • Section 5.8.3 herein (for other Underlayment systems). 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing pressure divided by 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct-to-Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition, Appendix A, Table 1A or the critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. #1 Maximum Design Pressure=-442.S Psf. Deck: Min.2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction Base Sheet: GAFGLAS#75 Base Sheet,Tri-Ply#75 Base Sheet,GAFGLAS#80 Ultima Base Sheet,GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. NEMO ETC,LLC Evaluation Report 01506.04.08-R21 Certificate afAuthorizatlon#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R21 GAF Roof Underlayments Revision 22:04/14/2021 Page 5 of 8 it ONEMO I etc. 5.8.3.2 Mechanically-Attached Base Sheet: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively,the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1,FM Loss Prevention Data Sheet 1-29,Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February for ( ry 2020) enhancements. #2 Maximum Design Pressure=-45 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 Ultima"m Base Sheet or Rubero)d® 20 Smooth mechanically attached with 12 ga., min.1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the min.4-inch wide side laps and 9-inch o.c.at two(2),equally spaced,staggered center rows in the field of the sheet. Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. #3 Maximum Design Pressure=-75 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 Ultima'"" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min.1.25-inch long ring shank nails through 32 ga.,1-5/8-inch diameter tin caps spaced 8-inch o.c. at the min.4-inch wide side laps and 8-inch o.c.at three(3),equally spaced,staggered center rows in the field of the sheet. Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. #4 Maximum Design Pressure=-97.5 psf. Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: GAFGLAS® #80 UltimaT" Base Sheet or Ruberoid® 20 Smooth mechanically attached with 11 ga., min. 1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the min.2-inch wide side laps and 4-inch o.c.at four(4),equally spaced center rows in the field of the sheet. Cap Sheet: Ruberoid®Mop Granule or Ruberoid®Mop Granule FR applied in full mopping of ASTM D312,Type IV hot asphalt at 20 to 25 Ibs/square. NEMO ETC,LLC Evaluation Report 01506.04.08-R21 Certiftcate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL10626-R21 GAF Roof Underlayments Revision 21:04/14/2021 Page 6 of 8 ONEMOletc. 5.9 Exposure Limitations: TABLES: EXPOSURE LIMITATIONS, Prepared Roof Cover Maximum Underlayment Installation Type Exposure (days) Deck-Armotm Premium Breathable Roof Deck Protection,FeltBuster®High-Traction Synthetic Roofing Felt,Shingle-Mate®Roof Deck Protection,StormSafeTM Anchor Sheet,Tiger Pawl Roof Deck Protection,VersaShield®Fire-Resistant Roof Deck Mechanically attached 30 Protection,GAF Extended Dry-In Membrane,LibertyTM'SBS Self-Adhering Base/Ply Sheet,StormGuard®Film Surfaced Leak Barrier and WeatherWatch®Mineral Surfaced Leak Barrier Ruberoid®Mop Granule and Ruberoid®Mop Granule FR Adhesive-set tile roof system 180 Mechanically attached UNLIMITED 5.10 Tile Slippage Limitations:When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 4- TILE SLIPPAGE LIMIfATIONSfOR DIRECT=DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Staging Slope Flat Max.10-tile stack 4:12 Ruberoid®Mop Granule Flat Max.6-tile stack(4 over 2) 5:12 Lugged Max.10-tile stack 5:12 Ruberoid®Mop Granule FR Flat or Lugged Max.6-tile stack(4 over 2) 5:12 17 Lugged Max.10-tile stack 4:12 6.1 GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application and prime the substrate(if applicable). 6.3 - Deck-'Armor'"Premium Breathable Roof Deck Protection or Tiger"0' mi``Roof.Deck Protection: 71 6.3.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception) or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.4 FeltBuster®High-TractionSynthetic=Roofing Felt: 6.4.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception), 1507.1.1.1(3,Exception)or 1507.1.1.1(S)or FBC Residential R90S.1.1.1(2,Exception),R905.1.1.1(3,Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5 StormSafe m:Anchor°Sheet: 6.5.1 StormSafeTm Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems. MEMO ETC,LLC Evaluation Report 01506.04.08-R21 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1121 GAF Roof Underlayments Revision 21:04/14/2021 Page 7 of 9 ONEMOletc. 6.5.2 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception) or 1507.1.1.1(3,Exception)or FBC Residential R905.1.1.1(2,Exception)or R905.1.1.1(3,Exception)for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.5.3 One the same day, install Liberty'"' SBS Self-Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier or WeatherWatch®Mineral Surfaced Leak Barrier over the StormSafe'""Anchor Sheet. 6.6 Shingle-Mate®.Roof Deck Protection:, 6.6.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM D226,Type II)in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. C7- VersaShield®Fire-Resistant Roof Deck Protection: 6.7.1 Shall be installed in compliance with requirements for an approved mechanically attached underlayment(ASTM D6757)in FBC Table iS07.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.8 GAF.Extended Dry-In"Membrane, Liberty''SBS Self-Adhering Base/Ply Sheet,StormGuard®Film Surfaced-Leak Barrier.or WeatherWatch®Mineral Surfaced Leak"Barrier: . 6.8.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R90S.1.1.3 for the type of prepared roof covering to be installed,and the manufacturer's installation instructions. 6.8.2 Back-nailing is required. Back-nailing shall consist of Approved cap nails spaced 18-inch o.c.,encapsulated within min.4-inch side laps. 6.8.3 When installed over a mechanically attached,FBC Approved ASTM D226 Type II felt,the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.8.4 GAF Extended Dry-In Membrane, Liberty'"'SBS Self-Adhering Base/Ply Sheet,StormGuard®Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system. 6.9 Ruberoid®Mop-Granule;Ruberoid®Mop Granule FR: 6.9.1 Shall be installed in compliance with requirements as an alternate to the"Hot Asphalt Applied Cap Sheet" in the "Two Ply System" in the FRSA/TRI Florida Nigh Wind Concrete and Gay Roof Tile Installation Manual, Sixth Edition,and the manufacturer's installation instructions. 6.9.2 Refer to Sections 5.8.2 and 5.8.3 herein for attachment limitations. 6.9.3 Refer to Table 4 for the staging limitations. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. QUALITY9. UL, LLC.—QUA9625;(414)248-6409;karen.buchmann@ul.com -END OF EVALUATION REPORT- NEMO ETC,LLC Evaluation Report 01506.04.08-R21 Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.10626-1121 GAF Roof Underlayments Revision 21:04/14/2021 Page 8 of 8 REVIEWED FO M 100 I me ri L E COMPLIANCE g A LUCIE COUNTY 26 gauge (min) 16" wide nail strip Bgftver 15/32" plywood Florida Product Approval Number 28113.1 /�. File CA Compliance statement:t This product as described has demonstrated compliance with Florida Building Code 2020, Section 1504.3.2, as required by Rule 61.G20=3, method 1 D Manufacturer: Integrity,Metals, LLC 12640 Piper Dr, Ste. B,Vero Beach, FL 32960:1772-584-26541 www.intregritymetalsfl.com Product: IntegriLok IM100 is a nailstrip panel with a 16" maximumpanel width, and nominal rib height of 1." 'Material: This product is manufactured from 26ga or thicker steel with.yield, . strength of at least 50ksi, and,corrosion resistance per FBC' 1507.4.3. Fastener: - #10 x 1" low-profile style fastener.compliant.with FBC 1506.6... Larger diameter and longer length fasteners are acceptable. Stainless steel fasteners may be used. Substrate/Deck: Minimum 15/32"thick plywood. .,". Underlayment: Comply with FBC 1507.1.1 where applicable. Slope: Comply `FBC 1507.4.2 where applicable. TechnicaMocumentation: This producthas been tested to he UL 580-06 standard-by Intertek Testing (TST-1527)- report 17726.05-450-44 R0: This test report"is used with permission., This productha`s also been tested to UL 580-06 and UL 1897-15 by-lntertek,- report K4846.01-450-44 R0. Max.Allowable Loads& Method A: 78.5psf I Install fasteners every other hole (±10" o.c.). Installation;Requirements:..Method:B: fi0.8.5psf i Use self-adhering underlayment and install fasteners.in every hole (±5" o c ) F f Factor of Safety of2.0 applied:.to calculate allowable loads Evaluated By: David Eng, PE Timberlake Cove, LLC �D E sFG '� PE LicV No: 81377 Univ. #206, Gainesville FL 32607 ti 2*X&_ . CA Lic. No: 33344 .81377 www.timberlakecove.com O•c�•. STATE OF (1441 � • ` www.IntegrityMetaisFI.com Page 1 '�,'ONAL 0E,.� INTEGRITY 2604 Piper St Ste B METALS Vero Beach FL 32609 METAL ROOFING MADE HERE (772) 584-2654 Panel Accessories: The manufacturer does not require the use of closures, sealants, butyl, or other similar accessories between bottom edge of panel and drip edge, or in other locations. The use of closures and sealants may be advisable in some cases, however that decision is the discretion of the project owner and the installer. Certification of Independence: David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company manufacturing or distributing products under this evaluation. The same entities do not have, nor will acquire, a financial'. interest in any other entity involved in the approval process ofthe product. Exclusions:� Limitations: Design of-deck and roof structure (to include attachment of plywood or wood plank) shall be completed by others. Fire classification and shear diaphragm design_ are outside,the-. '," scope of this evaluation. This report is limited to compliance with Ural 'wind load requirements of FBC-1504.3:2, as required`by Rule-61 G20 3. Neither Timberlake-,Cove nor the manufacturer shall be responsible for any conclusions, interpretations, or designs made by others based or :this evaluation report. This=report is limited.solely to documenting compliance with Rule 61 G20-3; and:makes no express or implied--,warranty ' regard' performance of this product. Design Process: The load tables in.this report-provides one prescriptive option for.the fastening requirement for the applicable wind loads for roofs within the°parameters described. For roofs ..outside of the listed parameters, design wind loads shall•be determined as required ty'FBC 1609, ASCE 7, or°other design code in force, using allowable stress.These load tables are-based on ASCE 7-16. Use of these tables , ,as sumes"that the structure is: n' Enclosed and conforms to wind-borne debris provisions and is a regular shaped building ■ ls,not subject to across wind loading, vortex shedding, or "r i `instability; nor does it have-a site:location`for which j channeling`or buffeting warrant consideration r ; En meenn' `anal sis may be"completed by other licensed engineers for project specific approval by local authorities having jurisdiction. FL28113.1 www.IntegrityMetaisFi.com Page 2 INTEGRITY 2604 Piper St Ste B METALS Vero Beach FL 32609 METAL ROOFING MADE HERE (772) 584-2654 Design Load Tables: 2 2 3 Select the appropriate load table that applies to the structure in question. 1 1 2 Determine the design wind speed for the project \X2 2 2 3 ...location. 2 1 2 2 3 Use the attachment methodindicated for that2 windspeed;within each roof:zone. 2 2 NOTE:ASCE7-16 and FRC 2020 adopt a 7-zone a 3 2 2 3 a concept.,Forthe load tables:below,the,worst case was taken for-each zone and-reported using the a HIP ROOF GABLE ROOF a standard zones 1-2-3: _ &%U%OF LEAST H020M L DIMENSION OR OAT,WHICHEVER IS SMALLER,am NOT SS THANZone 1 includes zones 1 and 1' ORASDET EMINEDB D SIGNOLEAST HORIZONTALTHERADVAENLE CODEN OR 3FT(a.9M). ORASDETERMINED%DESIGN OTHERAPPLICABLECOOS: Zone 2`includes zones 2e 2r; and 2n ROOF ZONES FOR'GENERIG'BUILDING Zone 3 includes zones 3e,and 3r Combining these zones creates a clear,simple scheme,at the expense of some-design efficiency. = Contact the 'manufacturer for further information, or consult a licensed design professional. Method A: (1)#10-x 1" (min)fastener,every other o hole (±10".oc ). =5,. Method B: (1)#10 x 1".(min)fastener,.every hole o '(±5"o.c.)With self-adhering underlayment NR: Consult:a design professional to assess the proposed installation' Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B,C,or D exposure area Have either a flat roof,or gable/hip roof with max slope of 45' Have either a flat roof,or gable/hip roof with max slope of 45' Have a mean roof height of 30 feet or less Have a mean roof height of 30 feet or less FL28813.1: 26 a IM100 1" nail strip on 15/32" plywood FL28813.1: 26 a IM100 1" nail strip on 15/32" plywood Wind 120 130 1.40 150 160 170 180 190 200 Wind 120 130 140 150 160 170 180 190 200 Zone 1: A A A` A A A A AFB, Zone 1: A A A_ A [ B B Zone 2: A A A A A FB B B Zone 2: A B B' Zone 3: A A . A A Fii7, B I ROOM Zone 3: d'B 'B Use this load table for structures which meet the following criteria: Use this load table for structures which meet the following criteria: Are located in Exposure B area Are located in B,C,or D exposure area Have either a flat roof less than 7',hip roof with Have either a flat roof less than 7',hip roof with max slope of 450,or gable roof with slope between 200 and 450 max slope of 450,or gable roof with slope between 20'and 450 Have a mean roof height of 30 feet or less Have a mean roof height of 30 feet or less FL28813.1: 26 a IM100 1" nail strip on 15/32" plvwood FL28813.1: 26cia IM100 1" nail strip on 15/32" Plywood Wind 120 130 140 150 160 170 180 190 200 Wind 120 130 140 150 160 170 180 190 200 Zone 1: A A A A -A A A A A Zone 1: A A A _A A B B Zone 2: A A A A A` A .rB �B B Zone 2: A A F B ,B B Zone 3: A A A A B B B.] �Zone 3: A B� B FL28113.1 www.integrityMetalsFi.com Page 3