Loading...
HomeMy WebLinkAboutEnergy CodeJam# 2/-o y-OS,��' FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUiLDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ._r. Project Name: PORTER MODEL- CUSTOM Builder Name. RODNEY HALL CONSTRUCTION f f . Street: 11771 APPALOOSA COURT Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34987 Permit Number. A Owner. Jurisdiction: ST LUCIE COUNTY Design Location: - FL, Fort Pierce County. St. Lucie: (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Types(2211.1 sgft) Insulation Area a. Concrete Block -Polystyrene Bead AggrER=4.1 2211.10 ftz 2. Single family or multiple family Detached b. NiA R= ftZ 3. Number of units, if multiple family 1 c. NiA R= ftZ 4. Number of Bedrooms 4 d. NIA 11. Ceiling Types (2379.0 sgft.) R= ftz Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2379.00 ftz 6. Conditioned floor.area above grade (ftz) 2379 b. N/A R= ftz R= ftZ Conditioned floor area below grade (ftz) 0 c. NIA R ftz 7. Windows(265.3 sgft.) Description Area 12. Ducts a. Sup: Attic, Ret: Attic, AH: A/H 5 175 a. U-Factor: Sgl. U=0.57 101-33 ftz SHGC: SHGC=022 b. U-Factor. Sgl, U=0.69 88.00 ftz 13- Cooling systems kBtuft r Efficiency SHGC: SHGC=0.22 a. Central Unit 39.5 SEER:14.00 c. U-Factor: Sgl, U=0.56 40.00 ftz SHGC: SHGC=0.24 14, Heating systems �kBtuft r Efficiency Area Weighted Average Overhang Depth: 10.461 f . a. Electric Strip Heat 7.0 COP:1.00 Area Weighted Average SHGC: 0.228 8. Skylights Area c. U-Factor:(AV.G) N/A ftZ t kWei i ystems SHGC(AVG): NIA Electric . , �.h -� : ' Gap: 40 altons 9. Floor Types (2379.0 sgft.) Insulation Area EF: 0.900 a. Stab -On -Grade Edge Insulation R=0.0 2379.00 ftz b. Conservation features b. NIA R= ftZ None c. NIA R= ftz 16. Credits None Total Proposed Modified Loads: 72.31 PASS Glass/Floor Area: 0.112 Total Baseline Loads: 77.39 I hereby certify that the plans and specifications covered by Review of the plans and O' ES this calculation are in compliance with the Florida Energy specifications covered by this �p�. Code. calculation indicates compliance with the Florida Energy Code. Mrrrr'- r`'. ,�••`��� 4 PREPARED BY. Before construction is completed DATE: 3-5-2021 this building will be inspected for c9. I+: compliance with Section 553.908 I hereby certify that .this ding, es ne , ' in pliance a Florida Statutes.; y�s �Ob with the Florida Energy od WV .. OWNERIAGENT- BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and insulation inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). ti 315/2021 9:15 AM EnergyGauge® USA 7.0:00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 7 ;V ....�.....■ ■��+v■ ACT o�onr�T FO-RMR405-2020 11vruI Quwnnwnmr vnw..■...+.._�• PROJECT Title: Title: PORTER MODEL- CUSTOM Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area 2379 Lot # BlocWSubdivision: Owner Name: Total Stories: 1 No PlatBook: # of Units: 1 Worst Case: 0 Street 11771 APPALOOSA CO Builder Name: RODNEY HALL CONSTRUC Rotate Angle: County. St. Lucie Permit Office: ST LUCIE COUNTY Cross Venblation: No City, State, Zip: FORT PIERCE, f Jurisdiction: ST LUCIE COUNTY Whole House Fan: No FL. 34987 Family Type: Detached NewlMdsting: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 °% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2379 25309A SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfmlID Finished Cooled Heated 1 BEDROOM 2 167 1553.1 No 0 1 1 Yes Yes Yes 2 CLST 2 20 186 No 0 1 Yes Yes Yes 3 BATH 60 558 No 0 1 Yes Yes Yes 4 BEDROOM 3 179 1664.7 No 0 1 1 Yes Yes Yes 5 HALL 32 297.6 No 0 1 No Yes Yes 6 WIC 3 30 �315 No 0 1 No Yes Yes 7 A8i 15 174 No 0 1 No Yes Yes 8 CLST 4 17 171.7 No 0 1 No Yes Yes 9 BEDROOM 4 150 1395 No 0 1 1 Yes Yes Yes 10 FOYER 146 1430.8 No 0 1 Yes Yes Yes 11 KITCHEN 159 2162A Yes 0 1 No Yes Yes 12 M. BEDROOM 289 3005.6 No 0 1 1 Yes Yes Yes 13 M. WIC 36 349.2 No 0 1 No Yes Yes 14 LAUNDRY ROOM 68 632.4 No 0 1 No Yes Yes 15 M.TOILET 15 139.5 No 0 1 No Yes Yes 16 M. BATH 117 1088.1 No 0 1 Yes Yes Yes 17 GREAT ROOM 428 5992 No 0 1 Yes Yes Yes 18 BONUS ROOM 427 3971.1 No 0 1 Yes Yes Yes 19 PANTRY 24 223.2 No 0 1 No Yes Yes 3/5/2021 9:15 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 . ..Aeu w r.V /+.J c/+tt'1 ICT OCOiit?`t' FORM R405-ZUZU mlru 1 %7um1vne+1[%. — - FLOORS # Floor Type Space Perimeter Perimeter R Value Area Joist R Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation BEDROOM 2 26 ft 167 ftz — 0 1 0 P 2 Slab -On -Grade Edge Insulation CLST 2 2 ft 20 ftz .— 0 1 0 3 Slab -On -Grade Edge Insulation BATH 6 ft 60 ftz — 0 1 0 4 Slab -On -Grade Edge Insulation BEDROOM 3 27 ft 179 ftz — 0 1 0 5 Slab -On -Grade Edge Insulation HALL 1 ft 32 ftz — 0 • 1 0 6 Stab -On -Grade Edge Insulation WIC 3 1 ft 30 ftz — 0 1 0 7 Slab -On -Grade Edge Insulation AIH 1 ft 15 ftz �— 0 1 0 8 Slab -On -Grade Edge Insulation CLST 4 1 ft 17 ftz -- 0 1 0 9 Slab -On -Grade Edge Insulation BEDROOM 4 21 ft 150 ftz _— 0 1 0 10Slab-On-Grade Edge Insulation FOYER 12 ft 146 ftz — 0 1 0 11SIab-On Grade Edge Insulation KITCHEN - - _I.ft__.....-------.--------- ----- 159 n'- ----- - — -- --- - ------- � - 0 12SIab-On-Grade Edge Insulation M. BEDROOM 34 ft 289 ftz — 0 1 0 13SIab-On�rade Edge Insulation M. WIC 1 ft 36 ftz — 0 1 0 14SIab-On-Grade Edge insulation LAUNDRY ROOM 1 ft 68 ftZ — 0 1 0 15SIab-On-Grade Edge Insulation M.TOILET 1 ft 15 ftz — 0 1 0 16SIab-On-Grade Edge Insulation M. BATH 12 ft 117 ftz — 0 1 0 17SIab-On-Grade Edge Insulation GREAT ROOM 28 ft 428 ftz — 0 1 0 18SIab-On-Grade Edge Insulation BONUS ROOM 58A ft 427 ftz _ 0 1 0 19SIab-On-Grade Edge Insulation PANTRY 1 ft 24 ftz — 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emid Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insui. (deg) 1 Hip Metal 2660 ftz 0 ftz Light N 0.1 No 0.9 No 20 26.57 ATTIC V/ # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2379 ftz N N 31512021915 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7 u..7..7W c s VKXKX A nv r%L§C^Vl ICY QCOrIPT FORM R4Ub-LULU I l r w .�a+..�.nr+... .....-.....-..- . - - - CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 2 0 Blown 167 ftz 0.1 Wood 2 Under Attic (Unvented) CLST 2 0 Blown 20 ftz 0.1 Wood 3 Under Attic (Unvented) BATH 0 Blown 60ftz 0.1 Wood i 4 Under Attic (Unvented) BEDROOM 0 Blown 179ftz 0.1 Wood 5 Under Attic (Unvented) HALL 0 Blown 32ft2 0.1 Wood 6 Under Attic (Unvented) WIC 3 0 Blown 30 ftz 0.1 Wood 7 Under Attic (Unvented) A/H 0 Blown 15 ftz 0 Wood 8 Under Attic (Unvented) CLST 4 0 Blown 17 ftz 0.1 Wood 9 Under Attic (Unvented) BEDROOM 4 0 Blown 150 ftz 0.1 Wood 10 Under Attic (Unvented) FOYER 0 Blown 146W 0.1 Wood 11 Under Attic (Unvented) KITCHEN 0 Blown 159ftz 0.1 Wood 12 Under Attic (Unvented) M.BEDROOM 0 Blown 289ftz 0.1 Wood 13 Under Attic (Unvented) M_ W IC 0 Blown 36 ftz 0.1 Wood 14 Under Attic (Unvented) LAUNDRY ROOM 0 Blown 68 ftz 0.1 Wood 15 Under Attic (Unvented) M.TOILET 0 Blown 15ftz 0.1 Wood 16 Under Attic (Unvented) M. BATH 0 Blown 117 ttz 0.1 Wood 17 Under Attic (Unvented) GREAT ROOM 0 Blown 428 ftz 0.1 Wood 18 Under Attic (Unvented) BONUS ROOM 0 Blown 427 ftz 0.1 Wood 19 Under Attic (Unvented) PANTRY 0 Blown 24 ftz 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 0 V# Space 141:10 1�xpe R-Alatile --Et In Et 'a- Area 1 nrnt E TO Exterior Concrete Block - PolysfyMBROOM 2 4.1 12 0 9 4 112.0 ftz 0 0 0.1 0 2 S Exterior Concrete Block- PolystyMBROOM 2 4.1 14 0 9 4 130.7 ftz 0 0 0.1 0 3 E Exterior Concrete Block - Polystyren6LST 2 4.1 2 0 9 4 18.7 ftz 0 0 0.1 0 4 E Exterior Concrete Block - Pclystyrend3ATH 4.1 6 0 9 4 56.0 ftz 0 0 0.1 0 - 5 N Exterior Concrete Block - PolystyMOROOM 3 4.1 14 0 9 4 130.7 ftz 0 0 0.1 0 6 E Exterior Concrete Block - Pclyr.WMIDROOM 3 4.1 13 0 9 4 121.3 ftz 0 0 0.1 0 _ 7 ^_ N Exterior Concrete Block - PolystyINIDROOM 4 4.1 12 0 9 4 112.0 ftz 0 0 0.1 0 8 E Exterior Concrete Block - PolystyMIDROOM 4 4.1 5 0 9 4 46.7 ftz 0 0 0.1 0 _ 9 W Exterior Concrete Block- Poiysty NIDR00M 4 4.1 4 0 9 4 37.3 ftz 0 0 0.1 0 _ 10 N Exterior Concrete Block - Polystyren60YER 4.1 11 4 9 10 111 A ftz 0 0 0.1 0 11 S Exterior Concrete Block- PolystyftdBEDR00 4.1 16 4 10 5 170.1 ftz 0 0 0.1 0 12 W Exterior Concrete Block - Polystod3dBEDROO 4.1 16 4 10 5 170.1 ftz 0 0 0.1 0 13 -14 W Exterior Concrete Block - Polystyreffi& BATH 4.1 12 0 9 4 112.0 ftz 0 0 0.1 0 S Exterior Concrete Block - Polysty%REAT ROO 4.1 24 0 14 0 336.0 ftz 0 0 0.1 0 _ 15 N Exterior Concrete Block - Polystyl3fd8IUS ROO 4A 15 0 9 4 140.0 ftz 0 0 0.1 0 16 ^_ NE Exterior Concrete Block - Polystyl b]US ROO 4.1 4 3 9 4 39.7 ftz 0 0 0.1 0 17 E Exterior Concrete Block - PolystyEONUS ROO 4.1 15 0 9 4 140.0 if 0 0 0.1 0 _ 18 W Exterior Concrete Block - Polysty NUS ROO 4.1 20 0 9 4 186.7 ftz 0 0 0.1 0 19 NW Exterior Concrete Block - PolystyBfd81US ROO 4.1 4 3 9 4 39.7 ftz 0 0 0.1 0 3/5/2021 9:15 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 �-, M A. nf%.,f% IK1011 r c1 IeeMAQv 1_ST RFPnIZT WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Metal Low-E Single Yes 0.56 0.24 Y 20.0 ftz 1 ft4 in 1 ft4 in None None 2 E 4 Metal Low-E Single Yes 0.56 024 Y 4.0 ftz 1 ft4 in 1 ft4 in None None 3 N 5 Metal Low-E Single Yes 0.57 0.22 Y 20.0 ftz 1 ft4 in 1 ft4 in None None 4 N 7 Metal Low-E Single Yes 0.57 022 Y 30.0 ftz 8 ft4 in 1 ft4 in None None 5 S 11 Metal Low-E Single Yes 0.69 022 Y 48.0 ftz 18 ft 4 in 1 ft4 in None None 6 W 13 Metal Low-E Single Yes 0.56 024 Y 16.0 ftz 1 ft4 in 1 ft4 in None None 7 S 14 Metal Low-E Single Yes 0.43 026 Y 36.0 ftz 18 ft4 in 1 ft4 in None None 8 S 14 Metal Low-E Single Yes 0.69 0.22 Y 40.0 ftz 18 ft4 in 1 ft4 in None None 9 N 15 Metal Low-E Single Yes 0.57 022 Y 15.0 ftz 1 ft4 in 1 ft4 in Drapes/blinds Exterior 5 10 NE 16 Metal Low-E Single Yes 0.57 0.22 Y 14.2 ftz 1 ft4 in 1 ft4 in Drapes/blinds Exterior 5 11 NW 19 Metal Low-E Single Yes. 0.57 0.22 Y 14.2 ftz 1 ft4 in 1 ft4 in Drapes/blinds Exterior 5 12 N 10 Metal Low-E Single Yes 0.57 0.22 Y 8.0 ftz 14 ft 4 in 1 ft4 in Drapes/blinds None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000338 2109.1 115.71 217.24 .1011 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPI 27 kBtumr . 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER: 14 39.5 kBtu/hr 1185 cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless BONUS ROOM0.9 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ftz 3/5/20219:15 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 v .......ek.unman wrnv t+ucf+lll 10 r OCOnOT FORMR4Ut-"LULU n�ru� va+..�mr.��. •+.••-•�•�--•--- -__ _ __ DUCTS — Supply— — Return — Air CFM 25 TOT CFM25 OUT QN RLF HVAC # Heat Cool # Location R-Value Area Location Area Leakage Type Handler 1 Attic 6 175 ftz Attic 18 ftz Default Leakage A/H (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat N Ceiling Fans: Cooling Jan [[ jj Feb Heating Jan (Xj Feb [[ ]] Mar [XJ Mar [ j j ]Apr Apr [ ] May j May [Xj Jun j Jun [Xj Jul E ] Jul AugXJ Aug Se j ] Sep Oct Nov O tX ct Nov Dec Decov Venting Jan [[ ]] Feb [[XXjj Mar �Xj Apr E ] May E ]Jun ]Jul t Au [ ]Sep Thermostat Schedule: HERS 2006 Reference Hours 8 9 10 11 12 Schedule Type 1 2 3 4 5 6 7 Cooling (WD) AM 78 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 80 80 78 78 78 80 78 PM80 Cooling (WEH) 80 80 80 80 78 78 78 78 78 78 80 70 8 80 78 PM Heating (WD) 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 Heating (WEH) 68 68 68 68 68 68 68 68 68 68 68 68 PM MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft= Oft 0.3 GUEST ROOM 1 Default(8 Ibslsq.ft. ftz ft 0.3 HALL 1 Default(8lbs/sq.ft ftz ft 0.3 BATH 1 Default(8 Ibs/sq.ft. ftz ft 0.3 LAUNDRY W IC Default(8 Ibs/sq ft ftz ft 0.3 LAUNDRY Default(8 Ibs/sq.ft. fLz ft 0.3 ENTRY Default(8 Ibs/sq.ft fiz ft 0.3 ENTRY WIC 2 Default(8 Ibs/sq.fL ftz ft 0.3 HALL Defoult(8 Ibs/sq ft. if ft 0.3 KITCHEN Defauft(8 Ibs/sq ft. ftz ft 0.3 ENTRY WIC 1 Default(8 Ibs/sq ft ftz ft 0.3 STORAGE Defauft(8lbs/sq.ft. ftz ft 0.3 DINING ROOM Default(8 Ibs/sq.ft ftz ft 0.3 FOYER Default(8 Ibs/sq- t. ftz ft 0.3 CLST 1 Defauft(8lbs/sgfL ftz ft 0.3 LIVING ROOM Default(8lbs/sq.fL fP ft 0.3 GUEST ROOM 3 Default(8 Ibs/sq.ft ftz ft 0.3 CLST 3 Default(8 ibslsq ft f? ft 0.3 BATH 3 Default(8 Ibs/sgft ftz ft 0.3 HALL W IC Default(8 Ibs/sq.ft. ftz ft 0.3 CLST 4 Default(8lbs/sq.ft. ftz ft 0.3 GUEST ROOM 4 Default(8 Ibs/sq.ft. ftz ft 0.3 HALL UP Default(8 Ibs/sgft. ftz ft 0.3 STAIRS OPEN Default(8 Ibslsgft. ftz ft 0.3 HALLWAY nafal IWA the/cn ft ftz ft 0.3 OFFICE 3/5/2021 9:15 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS ype FDefauft(8 Area Thickness Fumiture Fraction Space Ibs/sq.ft ftz ft 0.3 OFFICE CLST Default(8 Ibs/sq.fL ftz ft 0.3 HIS W IC Defauk(8 Ibs/sq.ft. ftz ft 0.3 HER W IC Default(8 lbs/sq ft ftz ft 0.3 BATH 2 Defauk(8lbs/sq.ft. ftz ft 0.3 WIC 2 Default(8 Ibs/sq.fL ftz ft 0.3 GUEST ROOM 2 Default(8 Ibs/sq.fL ftz ft 0.3 M TOILET Default(8 lbs/sq fL fl? ft 0.3 M BATH Defauk(8 Ibs/sq.fL ftz ft 0.3 MASTER BEDROO 3/5/2021 9:15 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edi ion (2020) Compliant Software Page 7 of 7 This document was created with Win2PDF available at http:llwww.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF. 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: PORTER MODEL- CUSTOM Builder Name: RODNEY HALL CONSTRUCTION Street: 11771 APPALOOSA COURT Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34987 Permit Number. Y w Owner. Jurisdiction: ST LUCIE COUNTY _ Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA . INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/saffit Ceiling/attic irsulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop downstairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame wails Walls The junction of the top plate and the top of exterior walls shall be sealed. shaft be insulated by completelyfilling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subtloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class 1 vapor retarder with overlapping joints taped. shag be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shag be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the finished surface. thermal envelope shag be air tight and IC rated, Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring an plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipina and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wag tubs shall separate them from the showers and tubs. insulated.. Electrical/phone box on The air barrier shag be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal. envelope shall be sealed to the sub floor, wall covering or ceiling Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. FORM'R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD • ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. y 11771 APPALOOSA COURT, FORT PIERCE, FL, 34987 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area a. Concrete Block - Polystyrene Bead AggrcR=4.1 2211.10 ftz 2. Single family or multiple family Detached b. NIA R= ft= 3. Number of units, if multiple family 1 c. NIA - R= ftz 4. Number of Bedrooms 4 d. NIA 11. Ceiling Type and insulation level R= ftz Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 2379.00 ftz 6. Conditioned floor area (ftz) 2379 b. NIA R= ftz c. N/A R= ftz 7. W indaws" Description Area 12. Ducts, location & insulation level R ftz a. U-Factor. Sgl, U=0.57 101.33 ftz a. Sup: Attic, Ret: Attic, AH: AIH 6 175 SHGC: SHGC=0.22 b. U-Factor. Sgl, U=0.69 88.00f12 SHGC: SHGC=0.22 13. Cooling systems kBtu/hr Efficiency c. U-Factor. Sgl, U=0.56 40.00 ftz a. Central Unit 39.5 SEER:14.00 SHGC: SHGC=0.24 d. U-Factor. other (see details) 36.00 ftz 14. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 10.461 ft. Area Weighted Average SHGC: 0.228 8. Skylights Description Area 15. Hot water systems Cap: 1 gallons a. U-Factor(AVG): WA ftz a. Electric EF: 0.9 SHGC(AVG): NIA b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 2379.00 ftz Credits (Performance method) None b. NIA R= fi= c. N/A R= ftz I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving eatures which will be installed (or exceeded) in this home before final i on. is a new EPL Display Card will be completed based on installed Co compli f % Builder Signature: Date: 3 _57 21 Address of New Home: I% �/l/ �� /da� C City/FL Zip:�C�7 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/5/2021 9:15 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1