HomeMy WebLinkAboutEnergy CodeJam# 2/-o y-OS,��'
FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUiLDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
._r. Project Name: PORTER MODEL- CUSTOM
Builder Name. RODNEY HALL CONSTRUCTION
f f . Street: 11771 APPALOOSA COURT
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34987
Permit Number.
A Owner.
Jurisdiction: ST LUCIE COUNTY
Design Location: - FL, Fort Pierce
County. St. Lucie: (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Types(2211.1 sgft)
Insulation Area
a. Concrete Block -Polystyrene Bead AggrER=4.1 2211.10 ftz
2. Single family or multiple family Detached
b. NiA
R= ftZ
3. Number of units, if multiple family 1
c. NiA
R= ftZ
4. Number of Bedrooms 4
d. NIA
11. Ceiling Types (2379.0 sgft.)
R= ftz
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2379.00 ftz
6. Conditioned floor.area above grade (ftz) 2379
b. N/A
R= ftz
R= ftZ
Conditioned floor area below grade (ftz) 0
c. NIA
R ftz
7. Windows(265.3 sgft.) Description Area
12. Ducts
a. Sup: Attic, Ret: Attic, AH: A/H
5 175
a. U-Factor: Sgl. U=0.57 101-33 ftz
SHGC: SHGC=022
b. U-Factor. Sgl, U=0.69 88.00 ftz
13- Cooling systems
kBtuft r Efficiency
SHGC: SHGC=0.22
a. Central Unit
39.5 SEER:14.00
c. U-Factor: Sgl, U=0.56 40.00 ftz
SHGC: SHGC=0.24
14, Heating systems
�kBtuft r Efficiency
Area Weighted Average Overhang Depth: 10.461 f .
a. Electric Strip Heat
7.0 COP:1.00
Area Weighted Average SHGC: 0.228
8. Skylights Area
c. U-Factor:(AV.G) N/A ftZ
t kWei i ystems
SHGC(AVG): NIA
Electric . , �.h
-� : ' Gap: 40 altons
9. Floor Types (2379.0 sgft.) Insulation Area
EF: 0.900
a. Stab -On -Grade Edge Insulation R=0.0 2379.00 ftz
b. Conservation features
b. NIA R= ftZ
None
c. NIA R= ftz
16. Credits
None
Total Proposed Modified Loads: 72.31
PASS
Glass/Floor Area: 0.112 Total Baseline Loads: 77.39
I hereby certify that the plans and specifications covered by
Review of the plans and
O' ES
this calculation are in compliance with the Florida Energy
specifications covered by this
�p�.
Code.
calculation indicates compliance
with the Florida Energy Code.
Mrrrr'- r`'. ,�••`��� 4
PREPARED BY.
Before construction is completed
DATE: 3-5-2021
this building will be inspected for
c9. I+:
compliance with Section 553.908
I hereby certify that .this ding, es ne , ' in pliance
a
Florida Statutes.;
y�s
�Ob
with the Florida Energy od
WV ..
OWNERIAGENT-
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and insulation inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
ti
315/2021 9:15 AM
EnergyGauge® USA 7.0:00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software
Page 1 of 7
;V
....�.....■ ■��+v■ ACT o�onr�T
FO-RMR405-2020
11vruI Quwnnwnmr vnw..■...+.._�•
PROJECT
Title: Title:
PORTER MODEL- CUSTOM
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area 2379
Lot #
BlocWSubdivision:
Owner Name:
Total Stories:
1
No
PlatBook:
# of Units:
1
Worst Case:
0
Street
11771 APPALOOSA
CO
Builder Name:
RODNEY HALL CONSTRUC
Rotate Angle:
County.
St. Lucie
Permit Office:
ST LUCIE COUNTY
Cross Venblation: No
City, State, Zip:
FORT PIERCE,
f Jurisdiction:
ST LUCIE COUNTY
Whole House Fan: No
FL. 34987
Family Type:
Detached
NewlMdsting:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp Heating Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 °%
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO BEACH_MUNI
39
90
70
75
299
62
Low
BLOCKS
Number
Name
Area
Volume
1
Entire House
2379
25309A
SPACES
Number
Name
Area
Volume Kitchen Occupants
Bedrooms
InfmlID
Finished Cooled
Heated
1
BEDROOM 2
167
1553.1
No
0
1
1
Yes
Yes
Yes
2
CLST 2
20
186
No
0
1
Yes
Yes
Yes
3
BATH
60
558
No
0
1
Yes
Yes
Yes
4
BEDROOM 3
179
1664.7
No
0
1
1
Yes
Yes
Yes
5
HALL
32
297.6
No
0
1
No
Yes
Yes
6
WIC 3
30
�315
No
0
1
No
Yes
Yes
7
A8i
15
174
No
0
1
No
Yes
Yes
8
CLST 4
17
171.7
No
0
1
No
Yes
Yes
9
BEDROOM 4
150
1395
No
0
1
1
Yes
Yes
Yes
10
FOYER
146
1430.8
No
0
1
Yes
Yes
Yes
11
KITCHEN
159
2162A
Yes
0
1
No
Yes
Yes
12
M. BEDROOM
289
3005.6
No
0
1
1
Yes
Yes
Yes
13
M. WIC
36
349.2
No
0
1
No
Yes
Yes
14
LAUNDRY ROOM
68
632.4
No
0
1
No
Yes
Yes
15
M.TOILET
15
139.5
No
0
1
No
Yes
Yes
16
M. BATH
117
1088.1
No
0
1
Yes
Yes
Yes
17
GREAT ROOM
428
5992
No
0
1
Yes
Yes
Yes
18
BONUS ROOM
427
3971.1
No
0
1
Yes
Yes
Yes
19
PANTRY
24
223.2
No
0
1
No
Yes
Yes
3/5/2021 9:15 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7
. ..Aeu w r.V /+.J c/+tt'1 ICT OCOiit?`t'
FORM R405-ZUZU mlru 1 %7um1vne+1[%. — -
FLOORS
# Floor Type
Space
Perimeter Perimeter R Value
Area
Joist R Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
BEDROOM 2
26 ft
167 ftz
—
0
1
0
P
2 Slab -On -Grade Edge Insulation
CLST 2
2 ft
20 ftz
.—
0
1
0
3 Slab -On -Grade Edge Insulation
BATH
6 ft
60 ftz
—
0
1
0
4 Slab -On -Grade Edge Insulation
BEDROOM 3
27 ft
179 ftz
—
0
1
0
5 Slab -On -Grade Edge Insulation
HALL
1 ft
32 ftz
—
0 •
1
0
6 Stab -On -Grade Edge Insulation
WIC 3
1 ft
30 ftz
—
0
1
0
7 Slab -On -Grade Edge Insulation
AIH
1 ft
15 ftz
�—
0
1
0
8 Slab -On -Grade Edge Insulation
CLST 4
1 ft
17 ftz
--
0
1
0
9 Slab -On -Grade Edge Insulation
BEDROOM 4
21 ft
150 ftz
_—
0
1
0
10Slab-On-Grade Edge Insulation
FOYER
12 ft
146 ftz
—
0
1
0
11SIab-On Grade Edge Insulation
KITCHEN -
- _I.ft__.....-------.--------- -----
159 n'-
----- - — -- ---
-
------- � -
0
12SIab-On-Grade Edge Insulation
M. BEDROOM
34 ft
289 ftz
—
0
1
0
13SIab-On�rade Edge Insulation
M. WIC
1 ft
36 ftz
—
0
1
0
14SIab-On-Grade Edge insulation
LAUNDRY ROOM 1 ft
68 ftZ
—
0
1
0
15SIab-On-Grade Edge Insulation
M.TOILET
1 ft
15 ftz
—
0
1
0
16SIab-On-Grade Edge Insulation
M. BATH
12 ft
117 ftz
—
0
1
0
17SIab-On-Grade Edge Insulation
GREAT ROOM
28 ft
428 ftz
—
0
1
0
18SIab-On-Grade Edge Insulation
BONUS ROOM
58A ft
427 ftz
_
0
1
0
19SIab-On-Grade Edge Insulation
PANTRY
1 ft
24 ftz
—
0
1
0
ROOF
Roof Gable Roof
Rad
Solar SA Emitt
Emid
Deck Pitch
# Type Materials
Area Area Color
Barr
Absor. Tested
Tested
Insui. (deg)
1 Hip
Metal 2660
ftz 0 ftz Light
N
0.1 No 0.9
No
20 26.57
ATTIC
V/
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS IRCC
1 Full attic
Unvented
0
2379 ftz
N N
31512021915 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7
u..7..7W c s VKXKX A nv r%L§C^Vl ICY QCOrIPT
FORM R4Ub-LULU I l r w .�a+..�.nr+... .....-.....-..- . - - -
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Unvented) BEDROOM 2
0
Blown
167 ftz
0.1
Wood
2
Under Attic (Unvented) CLST 2
0
Blown
20 ftz
0.1
Wood
3
Under Attic (Unvented) BATH
0
Blown
60ftz
0.1
Wood
i
4
Under Attic (Unvented) BEDROOM
0
Blown
179ftz
0.1
Wood
5
Under Attic (Unvented) HALL
0
Blown
32ft2
0.1
Wood
6
Under Attic (Unvented) WIC 3
0
Blown
30 ftz
0.1
Wood
7
Under Attic (Unvented) A/H
0
Blown
15 ftz
0
Wood
8
Under Attic (Unvented) CLST 4
0
Blown
17 ftz
0.1
Wood
9
Under Attic (Unvented) BEDROOM 4
0
Blown
150 ftz
0.1
Wood
10
Under Attic (Unvented) FOYER
0
Blown
146W
0.1
Wood
11
Under Attic (Unvented) KITCHEN
0
Blown
159ftz
0.1
Wood
12
Under Attic (Unvented) M.BEDROOM
0
Blown
289ftz
0.1
Wood
13
Under Attic (Unvented) M_ W IC
0
Blown
36 ftz
0.1
Wood
14
Under Attic (Unvented) LAUNDRY ROOM 0
Blown
68 ftz
0.1
Wood
15
Under Attic (Unvented) M.TOILET
0
Blown
15ftz
0.1
Wood
16
Under Attic (Unvented) M. BATH
0
Blown
117 ttz
0.1
Wood
17
Under Attic (Unvented) GREAT ROOM
0
Blown
428 ftz
0.1
Wood
18
Under Attic (Unvented) BONUS ROOM
0
Blown
427 ftz
0.1
Wood
19
Under Attic (Unvented) PANTRY
0
Blown
24 ftz
0.1
Wood
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar
Below
0
V#
Space
141:10 1�xpe
R-Alatile
--Et In
Et
'a-
Area
1
nrnt
E
TO
Exterior Concrete Block - PolysfyMBROOM 2
4.1
12
0 9
4
112.0 ftz
0
0
0.1
0
2
S
Exterior Concrete Block- PolystyMBROOM 2
4.1
14
0 9
4
130.7 ftz
0
0
0.1
0
3
E
Exterior Concrete Block - Polystyren6LST 2
4.1
2
0 9
4
18.7 ftz
0
0
0.1
0
4
E
Exterior Concrete Block - Pclystyrend3ATH
4.1
6
0 9
4
56.0 ftz
0
0
0.1
0
- 5
N
Exterior Concrete Block - PolystyMOROOM 3
4.1
14
0 9
4
130.7 ftz
0
0
0.1
0
6
E
Exterior Concrete Block - Pclyr.WMIDROOM 3
4.1
13
0 9
4
121.3 ftz
0
0
0.1
0
_
7
^_
N
Exterior Concrete Block - PolystyINIDROOM 4
4.1
12
0 9
4
112.0 ftz
0
0
0.1
0
8
E
Exterior Concrete Block - PolystyMIDROOM 4
4.1
5
0 9
4
46.7 ftz
0
0
0.1
0
_ 9
W
Exterior Concrete Block- Poiysty NIDR00M 4
4.1
4
0 9
4
37.3 ftz
0
0
0.1
0
_ 10
N
Exterior Concrete Block - Polystyren60YER
4.1
11
4 9
10
111 A ftz
0
0
0.1
0
11
S
Exterior Concrete Block- PolystyftdBEDR00
4.1
16
4 10
5
170.1 ftz
0
0
0.1
0
12
W
Exterior Concrete Block - Polystod3dBEDROO
4.1
16
4 10
5
170.1 ftz
0
0
0.1
0
13
-14
W
Exterior Concrete Block - Polystyreffi& BATH
4.1
12
0 9
4
112.0 ftz
0
0
0.1
0
S
Exterior Concrete Block - Polysty%REAT ROO
4.1
24
0 14
0
336.0 ftz
0
0
0.1
0
_ 15
N
Exterior Concrete Block - Polystyl3fd8IUS ROO
4A
15
0 9
4
140.0 ftz
0
0
0.1
0
16
^_
NE
Exterior Concrete Block - Polystyl b]US ROO
4.1
4
3 9
4
39.7 ftz
0
0
0.1
0
17
E
Exterior Concrete Block - PolystyEONUS ROO
4.1
15
0 9
4
140.0 if
0
0
0.1
0
_ 18
W
Exterior Concrete Block - Polysty NUS ROO
4.1
20
0 9
4
186.7 ftz
0
0
0.1
0
19
NW
Exterior Concrete Block - PolystyBfd81US ROO
4.1
4
3 9
4
39.7 ftz
0
0
0.1
0
3/5/2021 9:15 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7
�-, M A. nf%.,f% IK1011 r c1 IeeMAQv 1_ST RFPnIZT
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Omt ID Frame
Panes
NFRC
U-Factor SHGC Imp Area
Depth
Separation
Int Shade
Screening
1
S 2 Metal
Low-E Single
Yes
0.56 0.24 Y 20.0 ftz
1 ft4 in
1 ft4 in
None
None
2
E 4 Metal
Low-E Single
Yes
0.56 024 Y 4.0 ftz
1 ft4 in
1 ft4 in
None
None
3
N 5 Metal
Low-E Single
Yes
0.57 0.22 Y 20.0 ftz
1 ft4 in
1 ft4 in
None
None
4
N 7 Metal
Low-E Single
Yes
0.57 022 Y 30.0 ftz
8 ft4 in
1 ft4 in
None
None
5
S 11 Metal
Low-E Single
Yes
0.69 022 Y 48.0 ftz
18 ft 4 in
1 ft4 in
None
None
6
W 13 Metal
Low-E Single
Yes
0.56 024 Y 16.0 ftz
1 ft4 in
1 ft4 in
None
None
7
S 14 Metal
Low-E Single
Yes
0.43 026 Y 36.0 ftz
18 ft4 in
1 ft4 in
None
None
8
S 14 Metal
Low-E Single
Yes
0.69 0.22 Y 40.0 ftz
18 ft4 in
1 ft4 in
None
None
9
N 15 Metal
Low-E Single
Yes
0.57 022 Y 15.0 ftz
1 ft4 in
1 ft4 in
Drapes/blinds
Exterior 5
10
NE 16 Metal
Low-E Single
Yes
0.57 0.22 Y 14.2 ftz
1 ft4 in
1 ft4 in
Drapes/blinds
Exterior 5
11
NW 19 Metal
Low-E Single
Yes.
0.57 0.22 Y 14.2 ftz
1 ft4 in
1 ft4 in
Drapes/blinds
Exterior 5
12
N 10 Metal
Low-E Single
Yes
0.57 0.22 Y 8.0 ftz
14 ft 4 in
1 ft4 in
Drapes/blinds
None
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000338
2109.1 115.71 217.24
.1011
5
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None
COPI 27 kBtumr .
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split
Single SEER: 14 39.5 kBtu/hr 1185 cfm
0.8 1
sys#1
HOT WATER SYSTEM
#
System Type
SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric
Tankless
BONUS ROOM0.9 1 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model #
Area
Volume
FEF
None None
ftz
3/5/20219:15 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 v
.......ek.unman wrnv t+ucf+lll 10 r OCOnOT
FORMR4Ut-"LULU
n�ru� va+..�mr.��. •+.••-•�•�--•--- -__ _ __
DUCTS
— Supply—
— Return —
Air
CFM 25
TOT
CFM25
OUT QN RLF
HVAC #
Heat Cool
# Location R-Value Area
Location
Area
Leakage Type
Handler
1 Attic 6
175 ftz
Attic
18 ftz
Default Leakage
A/H
(Default) c(Default) c
1 1
TEMPERATURES
Programable Thermostat N
Ceiling Fans:
Cooling Jan [[ jj Feb
Heating Jan (Xj Feb
[[ ]] Mar
[XJ Mar
[ j
j ]Apr
Apr
[
] May
j May
[Xj Jun
j Jun
[Xj Jul
E ] Jul
AugXJ
Aug
Se
j ] Sep
Oct Nov
O tX ct Nov
Dec
Decov
Venting Jan [[ ]] Feb
[[XXjj Mar
�Xj
Apr
E
] May
E ]Jun
]Jul
t Au
[ ]Sep
Thermostat Schedule: HERS 2006 Reference
Hours
8
9 10 11
12
Schedule Type
1
2
3
4
5
6
7
Cooling (WD) AM
78
78
80
78
80
78
80
78
78
78
78
78
78
78
78
80 80 80
78 78 78
80
78
PM80
Cooling (WEH)
80
80
80
80
78
78
78
78
78 78 80 70
8
80
78
PM
Heating (WD)
68
68
68
68
68 68
68 68 68
68
68
PM
68
68
68
68
Heating (WEH)
68
68
68
68
68
68
68
68
68 68 68
68
PM
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft=
Oft
0.3
GUEST ROOM 1
Default(8 Ibslsq.ft.
ftz
ft
0.3
HALL 1
Default(8lbs/sq.ft
ftz
ft
0.3
BATH 1
Default(8 Ibs/sq.ft.
ftz
ft
0.3
LAUNDRY W IC
Default(8 Ibs/sq ft
ftz
ft
0.3
LAUNDRY
Default(8 Ibs/sq.ft.
fLz
ft
0.3
ENTRY
Default(8 Ibs/sq.ft
fiz
ft
0.3
ENTRY WIC 2
Default(8 Ibs/sq.fL
ftz
ft
0.3
HALL
Defoult(8 Ibs/sq ft.
if
ft
0.3
KITCHEN
Defauft(8 Ibs/sq ft.
ftz
ft
0.3
ENTRY WIC 1
Default(8 Ibs/sq ft
ftz
ft
0.3
STORAGE
Defauft(8lbs/sq.ft.
ftz
ft
0.3
DINING ROOM
Default(8 Ibs/sq.ft
ftz
ft
0.3
FOYER
Default(8 Ibs/sq- t.
ftz
ft
0.3
CLST 1
Defauft(8lbs/sgfL
ftz
ft
0.3
LIVING ROOM
Default(8lbs/sq.fL
fP
ft
0.3
GUEST ROOM 3
Default(8 Ibs/sq.ft
ftz
ft
0.3
CLST 3
Default(8 ibslsq ft
f?
ft
0.3
BATH 3
Default(8 Ibs/sgft
ftz
ft
0.3
HALL W IC
Default(8 Ibs/sq.ft.
ftz
ft
0.3
CLST 4
Default(8lbs/sq.ft.
ftz
ft
0.3
GUEST ROOM 4
Default(8 Ibs/sq.ft.
ftz
ft
0.3
HALL UP
Default(8 Ibs/sgft.
ftz
ft
0.3
STAIRS OPEN
Default(8 Ibslsgft.
ftz
ft
0.3
HALLWAY
nafal IWA the/cn ft
ftz
ft
0.3
OFFICE
3/5/2021 9:15 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
ype
FDefauft(8
Area
Thickness
Fumiture Fraction
Space
Ibs/sq.ft
ftz
ft
0.3
OFFICE CLST
Default(8 Ibs/sq.fL
ftz
ft
0.3
HIS W IC
Defauk(8 Ibs/sq.ft.
ftz
ft
0.3
HER W IC
Default(8 lbs/sq ft
ftz
ft
0.3
BATH 2
Defauk(8lbs/sq.ft.
ftz
ft
0.3
WIC 2
Default(8 Ibs/sq.fL
ftz
ft
0.3
GUEST ROOM 2
Default(8 Ibs/sq.fL
ftz
ft
0.3
M TOILET
Default(8 lbs/sq fL
fl?
ft
0.3
M BATH
Defauk(8 Ibs/sq.fL
ftz
ft
0.3
MASTER BEDROO
3/5/2021 9:15 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edi ion (2020) Compliant Software Page 7 of 7
This document was created with Win2PDF available at http:llwww.win2pdf.com.
The unregistered version of Win2PDF is for evaluation or non-commercial use only.
This page will not be added after purchasing Win2PDF.
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: PORTER MODEL- CUSTOM Builder Name: RODNEY HALL CONSTRUCTION
Street: 11771 APPALOOSA COURT Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL, 34987 Permit Number.
Y
w
Owner. Jurisdiction: ST LUCIE COUNTY
_
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA .
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/saffit
Ceiling/attic
irsulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop downstairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame wails
Walls
The junction of the top plate and the top of exterior walls shall be sealed.
shaft be insulated by completelyfilling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subtloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class 1 vapor retarder with overlapping joints taped.
shag be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shag be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on installation
Narrow cavities
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the finished surface.
thermal envelope shag be air tight and IC rated,
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring an
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pipina and Wring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wag
tubs shall separate them from the showers and tubs.
insulated..
Electrical/phone box on
The air barrier shag be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building thermal.
envelope shall be sealed to the sub floor, wall covering or ceiling
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
FORM'R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
• ESTIMATED ENERGY PERFORMANCE INDEX* = 93
The lower the EnergyPerformance Index, the more efficient the home.
y 11771 APPALOOSA COURT,
FORT PIERCE, FL, 34987
1. New construction or existing New (From Plans)
10. Wall Type and Insulation
Insulation Area
a. Concrete Block - Polystyrene Bead AggrcR=4.1 2211.10 ftz
2. Single family or multiple family Detached
b. NIA
R= ft=
3. Number of units, if multiple family 1
c. NIA -
R= ftz
4. Number of Bedrooms 4
d. NIA
11. Ceiling Type and insulation level
R= ftz
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 2379.00 ftz
6. Conditioned floor area (ftz) 2379
b. NIA
R= ftz
c. N/A
R= ftz
7. W indaws" Description Area
12. Ducts, location & insulation level
R ftz
a. U-Factor. Sgl, U=0.57 101.33 ftz
a. Sup: Attic, Ret: Attic, AH: AIH
6 175
SHGC: SHGC=0.22
b. U-Factor. Sgl, U=0.69 88.00f12
SHGC: SHGC=0.22
13. Cooling systems
kBtu/hr Efficiency
c. U-Factor. Sgl, U=0.56 40.00 ftz
a. Central Unit
39.5 SEER:14.00
SHGC: SHGC=0.24
d. U-Factor. other (see details) 36.00 ftz
14. Heating systems
kBtu/hr Efficiency
SHGC: other (see details)
a. Electric Strip Heat
27.0 COP:1.00
Area Weighted Average Overhang Depth: 10.461 ft.
Area Weighted Average SHGC: 0.228
8. Skylights Description Area
15. Hot water systems
Cap: 1 gallons
a. U-Factor(AVG): WA ftz
a. Electric
EF: 0.9
SHGC(AVG): NIA
b. Conservation features
9. Floor Types Insulation Area
None
a. Slab -On -Grade Edge Insulation R=0.0 2379.00 ftz
Credits (Performance method)
None
b. NIA R= fi=
c. N/A R= ftz
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving eatures which will be installed (or exceeded)
in this home before final i on. is a new EPL Display Card will be completed
based on installed Co compli f %
Builder Signature: Date: 3 _57 21
Address of New Home: I% �/l/ �� /da� C City/FL Zip:�C�7
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/5/2021 9:15 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1