HomeMy WebLinkAboutTruss&=LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY.
i
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Sp In or less o Sprez der Bar
60 degrees
or less
Jv-
Tap line , ,.n Iff-�+°4proz Zr3lo ^---..-y
ayµ.,a ep 1/2ofSpan
.
v
REFER TO BCSI REFER TO BCSI
Truss must be set this way d crane is used. Truss must be set this way if crane is used
Truss is an example, your truss may not match. Truss is an example, your truss may nor` match.
Insist crane operator seta trues this way. Insist crane operator sets truss IN, 1,,1Y,
All load hearing walls, headers,
beams, 8A, lintels must be in place
at indicated height before trusses
are installed.
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
ZL.\ G M.
The size of these trusses makes it necessary that they a set by a profeesjonal builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses_ The engineer should be at
the job site when trusses are erected to provide supervision and advice.
REPRESENTS THE LEFT SIDE OF
r?I, EACH TRUSS DRAWING
el
SEAT FLATLS BY C AMBERS TRUSS
J16REPRESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4, SUH46 FOR4X2 EXCEPT AS SHOWN
CARRIED CARRYING HANGER ID FASTENER FOR FASTENER FOR
TRUSS TRUSS CARRIED TRUS6 CARRYING TRUSS
td
r
1.
*Please refer to Standard Engineering package for general instuction on installing hangers
1Od=0.148" x 3" 16cli162" x 3 1/2"
egenc
I CEILING
AT 10'-0"
INDICATES
VOLUME
CEILING
LOAD
7/7 BEARING
AT 9'-4"
�l OTE.
ALa -... "I / 7 V fl ..rs�, ✓rs' RY® n-a-`-� E ■ M ti/ a
x;EDO N . .
HIP VALLEYS ARE DIFFICULT TO INSTALL, PROBLEMS CAN BE ADDRESSED BY CUTTING HIP VALLEYS IN HALF & FINDING CORRECT LOCATION.
Do not stand can trusses until t"5,i.ey Prebraced per BCSI & properly nailed to straps and hangers !!
&ARRANGE WITH CRANE OPERATOR IN ADVANCE FOR A SPREADER BAR OF 41' as 46' IN LENGTH!!
METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN.
SQUARE CUT END 12
2X4 TOP CHORD 6-
WALL HEIGHT 9'-4"
END DETAIL: COFFER
8 00
2-08-00
SQUARE CUT END
2X4 TOP CHORD
WALL HEIGHT 9'-4"
END DETAIL: TYPICAL
FABRICATION AGREEMEN
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED
The undersigned acknowledges and agrees: J
1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for
determining successful fabrication of the trusses.
2. All dimensions in this layout have been verified by the undersigned.
3. Unless written notice is provided by certified mail to Chambers Truss within ten (10) days of delivery the
undersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss
shall have three (3) business days in which to begin repairs required, or to substitute other trusses, at Chambers option.
After 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowledges receipt of "BCSI". summary sheet by TPI & WTCA.
5. Delivery is to job site. It is the buyers responsibility to make the job site suitable for delivery. Chambers Truss has
the sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will
be responsible for dump delivery only. The buyer is responsiblefor additional delivery expenses if.Chambers Truss has
to redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is -
responsible to Chambers Truss for towing costs due to site conditions.
E Price as shown in paragraph 7 below is subject to change if any changes are mado in this layout.'A $50 per hour
fee for revisions may be charged by Chambers Truss, i
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no' agreement a reasonable price.
Invoice will be made on delivery and paid within terms of net on delivery. Invoice maybe made at scheduled date of
delivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss.
reasonable attorneys fee for collections In event of payment not un ty made. 1-112 °h per month service charge wilt be
added for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned unconditionally guarantees'
'payment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the _
undersigned agrees to pay such indebtedness including attorneys fees, if default in payment for material be made by the: L.
recipient.
10, In the event of any litigation concerning this agreement. the items furnished hereunder or payments referred to
herein, the parties agree that the sole venue for any such action will be Saint Lucie County, Flodda.
- 11, Design responsibilities are per 7Mational Standard And Recommended Guidelines On Responsibilities For.
Construction Using Metal Plate Connected Wood Trusses ANSIITPIMrTCA 4 - 2002M
12. warranty is per Chambers Truss Warranty attached.
DATED
SIGNED
FOR TITLE
A spreader bar may be required per "BCSI" to prevent injury & damage.
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing are required and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
Trusses must be set and braced per design to prevent injury & damage.
Trusses must be set plumb and square
Do not set bunks or stack of plywood, roofing material or any other
concentrated loads on trusses, this can cause collapse.
AO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SE TRUSSES
to MB 7 . It.
*eanervenue
Fort Pierce, Florida 34982.6423
800.551.5932
Fort Pierce 772-465-2012 Fax 772-465-8711
Vero Beach 772.569.2012 Stuart 772-286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
jitEOat°
CODE C 0 M P L I A IMC.r
ST. LUCIE COUNT
BOCO
MITEK VERSION 7.4.1.431
_....
LOADING(DESIGN CRITERIA REDUCIBLE
PER CODE SUCH AS SBC 1604.6.1
DESIGN CRITERIA
County
ST LCIJE
COP*
Building Department
ST. LUCIE C LjR'rY`+
CW f
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(DirecUonal)/C-C hybrid Wind ASCE 7-16
Roofing Material
METAL
Loading in PSF
Roof R.D.L. Floor
Top Chord Live
20 0 -
Top Chord Dead
7 4.2 0
Bottom Chord Live
*10-Non Conccurent 0
Bottom Chord Dead
10 3 0
Total Load 47 7.2 0
Duration Factor 1.25 0
Wind Speed 170mph
Top Chord C.B. Sheathing by builder
Bottom Chord C.B. Sheathing by builder
Highest Mean Height 16,
Building Type Enclosed
Building Category Il: Non Restrictive
Exposure Category C>Open Terrain with scattered obstructions
Miles from Ocean 5
O r 2Ylk-fk' Cpv fY 1a41G� Conforms to Florida Building Code 2020
r eJ j CW R.D.L.=Restraining Dead Load C.B =Continuous Bracing
�w\tttlitloi;,� Verify DESIGN CRITERIA shown above with the
�.wlgs �r�% ' building department and your engineer.
ENSF Design Criteria is the responsibility of the .
o. 66 Building Designer and/or Engineer of Record
'r
STATE OF ty Z Chambers Truss Inc. Drawing Name: 77283
° SCALE: 1 /4" = 1'-011 1
139 total trusses, 48 unique designs
/77yyyJ NALt`�e�e� Designer: RLC Reviewed by: RLC
Date:: 02/09/21
�ummf �LS r� �K j �re✓tS/vj FOR
0 HOUSE FACTORY LLC
DESCRIPTION:
11771 APPALOOSA CT.
Page 1 of 1 CUSTOMER INITIALS EACH PAGE
77283
® Lumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
W.1 I
MiTek®
RE: 77283 - MiTek USA, Inc.
Site Information: 69
Customer Info: HOUSE FACTORY LLC Project Name: 11771 APPALOOSA CT Moc�7PAIED
Lot/Block: Subdivision:
Address: 11771 APPALOOSA CT 9
City: ST LUCIE COUNTY State: FL
Name Address and License # of Structural Engineer of Record, If there is one, fort ST' a County, Permitting
Name: License #:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.4
Wind Code: ASCE 7-10 Wind Speed: 170 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 48 individual, Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal#
Truss Name
Date
No.
Seal#
Truss Name
Date
1
T22789536
A
2/10/21
15
T22789550
B
2/10/21
2
T22789537
Al
2/10/21
16
T22789551
B1
2/10/21
3
T22789538
A2
2/10/21
17
T22789552
D
2/10/21
4
T22789539
A3
2/10/21
18
T22789553
D1
2/10/21
5
T22789540
A4
2/10/21
19
T22789554
D2
2/10/21
6
T22789541
A5
2/10/21
20
T22789555
D3
2/10/21
7
T22789542
A6
2/10/21
21
T22789556
D4
2/10/21
8
T22789543
A7
2/10/21
22
T22789557
D5
2/10/21
9
T22789544
A8
2/10/21
23
T22789558
D6
2/10/21
10
T22789545
A9
2/10/21
24
T22789559
D7
2/10/21
11
T22789546
ATA
2/10/21
25
T22789560
GRA
2/10/21
12
T22789547
ATB
2/10/21
26
T22789561
GRB
2/10/21
13
T22789548
ATC
2/10/21
27
T22789562
GRC
2/10/21
14
T22789549
ATD
2/10/21
28
T22789563
GIRD
2/10/21
This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc. under my direct supervision based on the parameters
provided by Chambers Truss.
Truss Design Engineer's Name: Velez, Joaquin
My license renewal date for the state of Florida is February 28, 2023.
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the judsdiction(s) identified and that the
designs comply with ANSI/TPI 1. These designs are based upon parameters
` shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek or TRENCO. Any project specific information included is for MiTek's or
TRENCO's customers file reference purpose only, and was not taken into account in the
preparation of these designs. MiTek or TRENCO has not independently verified the
applicability of the design parameters or the designs for any particular building. Before use,
the building designer should verify applicability of design parameters and properly
incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2.
t"1111111i1j1
I N
�i
81
.*; :*
3 T T OF '.IJ/ .`
SRO N
11111111111
Joaquin Velez PE No.68182
MITek USA, Inc. FL (:ert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
Velez, Joaquin 1 of 2
RE: 77283 -
Site Information:
MiTek USA, Inc.
6904 Parke East Blvd.
Tampa, FL 33610-4115
Customer Info: HOUSE FACTORY LLC Project Name: 11771 APPALOOSA CT Model:
Lot/Block: Subdivision:
Address: 11771 APPALOOSA CT
City: ST LUCIE COUNTY State: FL
No. Seal# Truss Name Date
29
T22789564
GRE
2/10/21
30
T22789565
HV8
2/10/21
31
T22789566
HVA
2/10/21
32
T22789567
A
2/10/21
33
T22789568
J3
2/10/21
34
T22789569
J5
2/10/21
35
T22789570
J7
2/10/21
36
T22789571
JA
2/10/21
37
T22789572
JA5
2/10/21
38
T22789573
JB
2/10/21
39
T22789574
JC
2/10/21
40
T22789575
KJ3
2/10/21
41
T22789576
KJ5
2/10/21
42
T22789577
KJ7
2/10/21
43
T22789578
V4
2/10/21
44
T22789579
V8
2/10/21
45
T22789580
V12
2/10/21
46
T22789581
V16
2/10/21
47
T22789582
V20
2/10/21
48
T22789583
V24
2/10121
2 of 2
Job
Truss
Truss Type
Qty
Ply
T22789536
77283
A
HIP
1
1
Job Reference (optional)
Chambers TtUss, In.^ ' Fort Pierce, FL 8.430 s Nov 30 2020 Mi-rek Industries, Inc. Wed Feb 10 09:04:49 2021 Page 1
I D:Iuptf7XWOPbi2TquAJ rctDzmxuU-OXQXByalcko7lAgnyiYU9LMbO W H4J I RQM QVOGzmazi
r1 4-l� 7-0-0 13-11-0 20-10-0 26-2-0 31 6-0 37-0 0-0 44 O O
7-0-0 6-11-0 6-11-0 5 4-0 5-4% 5 6 7-0-0
6.Oo 12
5x6 =
3x4 = 3x10 = 3x6 = 3x4 ll 3x8 =
5x6 =
274 28 5 6 7 29 308 9
32 19 33 1s 17 16 16 14 14 1L
Scale = 1:76.5
3x5 = 3x4 = 3x5 = 3x6 — 3x6 II 3x6 = 3x6 = 3x4 I I 3x4 = 3x5 —
7-0-0 13-11-0 20-10-0 26-2-0 31-0-0 37-0-0 44-0-0
7-0-0 6-11-0 6-11-0 5.4-0 511 5�-0 7-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc)
I/defl
Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.42
Vert(LL)
0.23 19-22
>999
240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.30
Vert(CT)
-0.14 19-22
>999
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.58
Horz(CT)
-0.01 16
n/a
n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix -MS
Weight: 216 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt 5-18
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=-199(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) except 2=996(LC 12), 16=-1389(LC
12),13=-447(LC 12),10=-392(LC 12)
Max Grav All reactions 250lb or less atjoint(s) except 2=771(LC 21), 16=1328(LC
1), 13=830(LC 22), 10=544(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1093/1373, 3-4=-914/1345, 4-5=-772/1330, 8-9=-429/423, 9-10=-512/358
BOT CHORD 2-19=-1002/910, 18-19=-996/772, 16-18=-382/630, 15-16=-382/630, 13-15=-157/274,
12-13=-157/274, 10-12=-1291359
WEBS 4-18=-470/487, 5-18=-1828/1294, 5-16=-1189/1399, 5-15=-376/461, 7-15=-264/275,
8-15=0/266,8-13=-735/549, 8-12=428/580
NOTES-
This item has been
1) Unbalanced roof live loads have been considered for this design.
electronically Signed and
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
sealed by Velez, Joaquin, PE
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 7-0-0, Exterior(21R) 7-0-0
using a Digital Signature.
to 13-2-11, Interior(1) 13-2-11 to 37-0-0, Exterior(2R) 37-0-0 to 43-5-8, Interior(1) 43-5-8 to 45-4-13 zone; porch left exposed;C-C for
Printed copies of this
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
document are not considered
to the use of this truss component.
signed and sealed and the
4) Provide adequate drainage to prevent water ponding.
Signature must be Verified
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
On any electronic copies.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Joaquin Velez PE No.68182
- will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 996 lb uplift at joint 2, 1389 lb uplift at
M1Tek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
joint 16, 447 lb uplift at joint 13 and 392 lb uplift at joint 10.
Date:
February 10,2021
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
'
Design valid for use only with MiTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
design. Bracing indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
i�niTek'
building prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPIf Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789537
77283
Al
HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., . Fort Pierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:04:50 2021 Page 1
ID:Iuptf7XWOPbi2TquAJrztDzmxuU-Uj_v01bxN2w vJFzWQ3jiYunMwShjDnaeOA2wizmazh
1-4-0 6-3-9 9-0-0 14-11-0 20-10-0 26-2-0 31-6-0 33-10.0 5-0-Q 41-4-0 44-0-0 45-4-q
1-4-0 6-3-9 2-8-7 5-11-0 5-11-0 5-4-0 5-4-0 2-4-0 -2-0 6-0-0 2-8-0
5x8 =
6.00 F12
34 5 3536
3x6 = 3x8 =
3738 39 9
5x6 =
10 11
41 26 25 24 42 23 22 21 20 197x8 = 15
3x5 = 3x6 =
9-0-0 14-11-0
20-10-0
6xB =
3x6 =
3x8 =
4x4 =
Scale = 1:77.8
3x6 = 3x5 =
LOADING (psf)
SPACING- 2-0-0
CS1.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.38
Vert(LL) 0.37 26-29 >682 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.98
Vert(CT) -0.27 26-29 >924 240
BCLL 0.0
Rep Stress Incr YES
WB 0.44
Horz(CT) 0.05 13 n/a n/a
BCDL 10.0
Code FBC20201TPI2014
Matrix -MS
Weight: 249 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 'Except*
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
10-19,12-15: 2x4 SP No.3
WEBS 1 Row at midpt 5-23, 12-17
WEBS 2x4 SP No.3
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=246(LC 11)
Max Uplift All uplift 100 lb or less at joints) except 2=964(LC 12), 13=-350(LC 12). 23=-1436(LC 12).
20=-475(LC 12)
Max Grav All reactions 250 lb or less at joint(s) except 2=747(LC 21), 13=451(LC 18), 23=1371(LC 21),
20=1015(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1027/1248, 3-4=-822/1135, 4-5=-426/833, 5-6=-335/443, 6-8=-335/443,
8-9=-98/353, 12-13=-615/451
BOT CHORD 2-26=-944/883, 24-26=-698/699, 23-24=-436/426, 21-23=169/437, 20-21=-169/437,
19-20=-269/223, 10-18=-270/164, 16-17=-918/1272, 13-15=-325/503
WEBS 3-26=-307/435, 4-26=-605/426, 4-24=353/433, 5-24=-543/377, 5-23=-1075/1475,
6-23=-299/304, 8-23=-453/390, 8-20=382/38, 9-20=-629/479, 18-20=-161/264,
9-18=-348/570, 12-17=-1351/1167
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 9-0-0, Exterior(2R) 9-0-0
to 15-2-11, Interior(1) 15-2-11 to 35-0-0, Exterior(2R) 35-0-0 to 41-5-12, Interior(1) 41-5-12 to 45-4-13 zone; porch left exposed;C-C
for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) All plates are 3x4 MT20 unless otherwise indicated.
6)'rhis truss has been designed for a 10.0 pat bottom chord jive load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 964 lb uplift at joint 2, 350 lb uplift at
.joint 13, 1436 lb uplift at joint 23 and 475 lb uplift at joint 20.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
6904 Parke. East Blvd. Tampa FL 33610
Data:
February 10,2021
I& WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
f'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rPl1 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789538
77283
A2
HIP
1
1
Job Reference (optional)
Chambers Truys, Inc., Fort P(prce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 14:36:08 2021 Page 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-sRoHaCUzsEewU I?Gir7siF4achC6hAGZmYJ PFDzmX?L
33-10-0
r1-4-0, 5-9-4 11-0-0 15.11.0 20.10-0 26-2-0 31-6-0 �33-0.0, 41-4-0 440.0 AS4-Q
,1- 0 5.9.4 5-2.12 4-11-0 4-1 IN 14-0 5-40 1.6-0 7.6.0 248.0
0-10-0 Scale = 1:77.2
5x6 = - 3x5 II
3x4 — 3x4 = 3x6 = 3x4 II 3x8 = 3x6 =
4 34 35 5 36 6 7 8 37 38 39 9 10 11
25 24 `_
3x5 = 3x4 II 3x6 =
3x8 =
5-9-4 11-0-0
22 20 19 18-" ,-
6x8 = 3x8 = 5x6 = 3x4 I I
4x6 =
15
3x6 = 3x5 =
3x4 I I
m
d
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/deft L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.37
Vert(LL)
0.42 22-24 >600 240
MT20 2441190
TCDL 7.0
Lumber DOL
1.25
BC 0.59
Vert(CT) -0.39 22-24 >646 240
BCLL 0.0
Rep Stress Incr
YES
WB 0.72
Horz(CT)
0.03 13 n/a n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix -MS
Weight: 257 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 *Except*
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
11-18,12-15: 2x4 SP No.3
WEBS
1 Row at midpt 5-22, 12-17
WEBS 2x4 SP No.3
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=-293(LC 10)
Max Uplift All uplift 100 lb or less at joints) except 2=914(LC 12), 13=-206(LC 12), 22=-1414(LC 12), 19=-691(LC
12)
Max Grav All reactions 250 lb orJess at joint(s) except 2=736(LC 23), 13=283(LC 18), 22=1488(LC 23), 19=1642(LC
18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-32=-1068/1318, 32-33=-1029/1319, 3-33=-985/1329, 3-4=-632/834, 4-34=513/825,
34-35=-513/825, 5-35=-513/825, 5-36=-428/619, 6-36=428/619, 6-7=-308/501,
7-8=-308/501,8-37=-308/501, 37-38=-308/501, 38-3R=308/501,9-39=-308/501,
9-10=-260/576, 10-11=-204/511, 11-40=-448/735, 40-41=461/628, 12-41=-463/583
BOT CHORD 2-42=-1013/929, 42-43=-1013/929, 25-43=-1013/929, 24-25=-1013/929, 21-22=-619/856,
20-21=-619/856, 19-20=-950/840, 11-17=-591/577, 16-17=-252/691
WEBS 3-25=-318/186, 3-24=-477/806, 5-24=688/671, 5-22=-980/1109, 6-22=-527/403,
6-20=-224/346, 8-20=-296/339, 9-20=-1511598, 9-19=-1204/600, 17-19=-823/914,
9-17=-371/638, 12-17=-13501908
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 11-0-0, Exterior(2R)
11-0-0 to 17-2-11, Interior(1) 17-2-11 to 33-0-0, Exterior(21R) 33-0-0 to 39-2-11, Interior(1) 39-2-11 to 45-4-13 zone; porch left
exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4� Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 914 lb uplift at joint 2, 206 lb uplift at joint
13, 1414 lb uplift at joint 22 and 691 lb uplift at joint 19.
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL,33610
Date:
February 10,2021
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.°
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek°
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
T22789539
77283
A3
Hip
1
1
Job Reference (optional)
Chambers Tiviss, Inc., r Fort Pierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:04:53 2021 Page 1
ID:Iuptf7XWOPbi2TquAJrztDzmxuU-vlfl OJdpgzlYmn_YBYdQKBWGf7ZwwRF1 L_OjXlzmaze
23-0-0
r1-0-0, 6-0-5 11-412 17-0-0 20.6-0 21-%0 L1%-13 36-7-11 44-0-0
1-0-0 6-0-5 5-0-7 5-7.4 3-6-0 06- 2-0-0 6-9-13 6-9-13 7-0-5
3x6 =
5x6 =
5x8 =
6.00 12 7
8 32
20 18 17 16 �- 15 13
5x6 WB = 5x8 = 4x10 = 4x6 =
12x12 II
3.00 12
23-0-0
Scale = 1:78.7
3x6 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0 '
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/TPI2014
CSI.
TC 0.51
BC 0.69
WB 0.97
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Udefi Ud
-0.31 20-21 >999 360
-0.54 20-21 >984 240
0.17 12 n/a file
0.29 18 >999 240
PLATES GRIP
MT20 244/190
Weight: 283 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural woad sheathing directly applied or 3-4-11 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD
Rigid ceiling directly applied or 5-0-10 oc bracing.
WEBS 2x4 SP No.3 WEBS
1 Row at midpt 6-20, 6-19, 8-16, 7-17, 9-16
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 12=Mechanical
Max Horz 2=519(LC 11)
Max Uplift 2=-1153(LC 12), 12=-1029(LC 12)
Max Grav 2=2054(LC 17), 12=1972(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3769/2249, 3-4=-3562/2162, 4-6=2660/1832, 6-7=2462/1810, 7-8=-2168/1675,
8-9=-2244/1668, 9-11=-3009/1950, 11-12=-3740/2254
BOT CHORD 2-21=-1916/3688, 20-21 =-1 561/3132, 19-20=-1231/2656, 15-16=-1377/2529,
13-1 5=-1 866/3273, 12-13=-186613273
WEBS 3-21=-382/370, 4-21=-241/702, 4-20=-811/532, 6-19=-471/435, 8-16=-398/281,
9-15=-220/679, 11-15=-849/576, 11-13=-1/294, 7-19=-708/1014, 9-16=-1103/728,
16-19=-989/2336,8-19=-479/1263
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; VuIt=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 21-0-0, Exterior(2E)
21-0-0 to 23-0-0, Exterior(2R) 23-0-0 to 29-2-11, Interior(1) 29-2-11 to 44-0-0 zone;C-C for members and forces & MWFRS for
This item has been
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
electronically signed and
to the use of this truss component.
sealed by Velez, Joaquin, PE
4) Provide adequate drainage to prevent water ponding.
using a Digital Signature.
5) All plates are 3x4 MT20 unless otherwise indicated.
Printed Copies Of this
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
document
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
are not considered
'will fit between the bottom chord and any other members, with BCDL = 1o.Opsf.
signed and sealed and the
8) Refer to girder(s) for truss to truss connections.
Signature must be Verified
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1153 Ito uplift at joint 2 and 1029 lb uplift
on any electronic copies.
at joint 12.
Joaquin Velez PE No.68182
�
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPlf Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789540
77283
A4
Roof Special
6
1
Job Reference (optional)
Chambers Truss, Inc., } Fort Pierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:04:54 2021 Page 1
ID:Iuptf7XWOPbi2TquAJrztDzmxuU-NVDP EfeRRGQPOxZkIFBfsO3OSXgxfuPAZe8G3Uzmazd
.1 4 q 6-0-5 11 4-12 17-0-0 22-0-0 , 29-2-3 3p-2-p 36-4-6 AIM
113 0 6-0-5 5 4 7 5-7.4 5-0-0 7-2 3 0- 1- 3 6-2 6 7-7-10
5x6 =
6.00 12
14
4x5 = 5x8 = 6x8 = 3.00 F12
4x4 =
B-9-4 1 17-0-0 22-0-0 , 30-2-0
Scale = 1:78.6
4x12
4x4 11
A
10 cn A
Iv
0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/TPI2014
CSI.
TC 0.70
BC 0.90
WB 0.98
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/deft L/d
-0.49 12-13 >999 360
-0.87 12-13 >605 240
0.43 10 n/a n/a
0.64 12 >826 240
PLATES
MT20
MT18HS
Weight: 277 lb
GRIP
244/190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-5-5 oc purlins.
BOT CHORD 2x6 SP No.2 *Except*
BOT CHORD
Rigid ceiling directly applied or 4-5-9 oc bracing.
10-12: 2x6 SP 240OF 2.0E
WEBS
1 Row at midpt 5-14,
5-13, 6-13, 7-13
WEBS 2x4 SP No.3 *Except*
7-13,7-12: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=Mechanical
Max Horz 2=542(LC 11)
Max Uplift 2=-1155(LC 12), 10=-1031(LC 12)
Max Grav 2=2022(LC 17), 10=1928(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3769/2305, 3-4=-3565/2212, 4-5=-2614/1863, 5-6=-2371/1798, 6-7=2456/1779,
7-9=-5526/3479, 9-1 0=-6571/401 0
BOT CHORD 2-15=-1968/3709,14-15=-1601/3139,13-14=-1265/2654,12-13=-2764/4844,
11-12=-3521/5979, 10-11=-3519/5968
WEBS 3-15=-376/371, 4-15=-260/739, 4-14=838/544, 5-13=-471/433, 6-13=-1169/1839,
7-13=-3481/2129, 7-12=-1540/2949, 9-12=-980/671
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat,
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 22-0-0, Exterior(2R)
This item has been
22-0-0 to 264-13, Interior(1) 26-4-13 to 44-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
electronically signed and
plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
sealed by Velez, Joaquin, PE
to the use of this truss component.
using a Digital Signature.
4) All plates are MT20 plates unless otherwise indicated.
Printed copies Of this
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
document are not considered
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
signed and sealed and the
7) Refer to girder(s) for truss to truss connections.
Signature must be Verified
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1155 lb uplift at joint 2 and 1031 lb uplift
on any electronic copies.
at joint 10.
Joaquin Velez PE No.68163
�
MiTek'USA, Inc. FL Cert 8634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIR'pl1 Quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789541
77283
A5
Roof Special
3
1
Job Reference (optional)
Chambers Truss, Inc., 0 Fort Pierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:04:55 2021 Page 1
ID:luptf?XWOPbi2TquAJ rztDzmxuU-rhnoR?e3C aYGO57wJzfu P ccZDx9zO KnJo Itpbwzm azc
1 4 2 8-0 14-8-0 17-0-0 22-0-0 29-2-3 3 -2 36-4-6 44-0-0 4- 2 8 0 6-0-0 6-0-0 2-4-0 5-0-0 7-2-3 0- 1- 3 6-2-0 7-7-10
m
0
5x6 =
6.00 F12
3x4 I 4x5 = 17 16 V
6x10 = 4x6
6x8 = 3.00 F12
4x12 % 4 00 1zzzp 3x4 I I 4x4 I I
1ox14 MT�S i
2-8-0 , 8-8-0 1 14-8-0 17-0-0 , 22-0-0 30-2-0
Scale = 1:87.9
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/TP12014
CSI.
TC 0.70
BC 0.97
WB 0.97
Matrix -MS
DEFL. in ([cc) Vdefl L/d
Vert(LL) -0.50 14 >999 360
Vert(CT) -0.94 14-15 >561 240
Horz(CT) 0.57 12 n/a n/a
Wind(LL) 0.75 14 >704 240
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 303 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-7-2 cc purlins.
BOT CHORD 2x6 SP No.2 *Except*
BOT CHORD
Rigid ceiling directly applied or 2-2-0 cc bracing.
2-21: 2x4 SP M 30, 18-20,2-20: 2x6 SP 240OF 2.0E
WEBS
1 Row at midpt 3-19,
4-18, 7-18, 7-16, 7-15, 8-15, 9-15
6-17: 2x4 SP No.3
WEBS 2x4 SP No.3 *Except*
9-15: 2x4 SP M 30
OTHERS 2x4 SP M 30
REACTIONS. (size) 2=0-8-0, 12=Mechanical
Max Horz 2=542(LC 11)
Max Uplift 2=-1155(LC 12), 12=-1031(LC 12)
Max Grav 2=1705(LC 1). 12=1627(LC 1)
FORCES. (lb) -Max. Camp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-6381/4296, 3-4=-3643/2576, 4-6=-2743/2074, 6-7=-2660/2189, 7-8=-2147/1791,
8-9=-2194/1778,9-11=-4963/3483,11-12=-5717/4025
BOT CHORD 19-20=-3651/5758, 18-19=-2158/3489, 6-18=-208/266, 16-17=-298/428,
15-16=-1263/2189, 14-15=2769/4425, 13-14=3536/5211, 12-13=3535/5198,
2-20=-3894/6212
WEBS 3-19=-2285/1503, 4-19=-245/581, 4-18=-11471788, 16-18=-981/1775, 7-18=914/1396,
7-16=-999/614, 7-15=-410/439, 8-15=-116011518, 9-15=-2955/2133, 9-14=1545/2536,
11-14=-861/682, 3-20=-781/1429
NOTES-
1 ) Unbalanced roof live loads have been considered for this design.
This item has been
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
electronically signed and
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 2-9-12, Interior(1) 2-9-12 to 22-0-0, Exterior(2R)
sealed by Velez, Joaquin, PE
22-0-0 to 26-4-13, Interior(1) 26-4-13 to 44-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
using a Digital Signature.
plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
Printed copies of this
to the use of this truss component.
document are not considered
4)rAll plates are MT20 plates unless otherwise indicated.
signed and sealed and the
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Signature must be Verified
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
on any electronic copies.
will fit between the bottom chord and any other members.
Joaquin Velez PE No.68182
7) Refer to girder(s) for truss to truss connections.
8) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
MiTek USA, Inc..FL Cart 8834
6904 Parke East Blvd. Tampa FL 33610
capacity of bearing surface.
Date:
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1155 lb uplift at joint 2 and 1031 lb uplift
at joint 12.
February 10,2021
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE.MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall
building design. Bracing Indicated is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
r
MiTek"
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789542
LobReference
77283
A6
Hip
1
1
(optional)
Chambers Truss, Inc., 4 FortPierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:04:57 2021 Page 1
ID:Iuplf7XWOPbi2TquAJrztDzmxuU-n3vYshgKjBo—FOHJQOhMU1 hvtlrLsEjcFcMwgozmaza
223-8
1-0 2-0-0 8A-0 144i0 17-0-0 21-8-8 22 29-" 3 2 LEVI44-0-0
1-0-0 2-8-0 6-0-0 6-0-0 24-0 43-8 7-1-0 9 63-9 78-7
033
5x8 MT18HS = Scale = 1:92.2
6.00 12
A
12 A
Ip
-� -- 17 16 4X1u
3x4 II 45 = 6xl0 = 4x6ZZ
4x12 - 6x8 = 3.00 12
4.00 12 3x4 II 4x4 II
10x14 MITiBHS i
22-M
i 2-e-0 8A-0 14-8-0
17-0.0
21A-8 22 W 30-2-0
i 3C>S9 i _ 44-0-0
2A-0 6-0-0
2-0-0
'I_.D4L8 7-10-8
63-9 7-0-7
03-8
Plate Offsets (X Y)— [5:0-3-0 Edge] [10:0-3-0,Edge] [12:0-10-7 0-0-141, 112:0-1-8 0-3.21, [12:0-1-6,0-0-81, [16:0-5-8,0-3-81, [18:0-4-12,0-2-01,
[20:0-5-4.0-5-81
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(too) Vdefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.68
Vert(LL) -0.50
14 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.98
Vert(CT) -0.94
14-15 >562 240
MT18HS 244/190
BCLL 0.0
Rep Stress Incr YES
WB 1.00
Horz(CT) 0.57
12 n/a n/a
BCDL 10.0
Code FBC2020fTP12014
Matrix -MS
Wind(LL) 0.75
14 >705 240
Weight: 303 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-7-7 oc purlins.
BOT CHORD 2x6 SP No.2 'Except'
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
2-21: 2x4 SP M 30, 18-20,2-20: 2x6 SP 240OF 2.0E
WEBS
1 Row at midpt 3-19, 4-18, 7-16, 7-15, 9-15, 8-15
6-17: 2x4 SP No.3
WEBS 2x4 SP No.3 *Except*
9-15: 2x4 SP M 30
OTHERS 2x4 SP M 30
REACTIONS. (size) 2=0-8-0, 12=Mechanical
Max Horz 2=539(LC 11)
Max Uplift 2=-1155(LC 12), 12=-1031(LC 12)
Max Grav 2=1705(LC 1), 12=1627(LC 1)
FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-6380/4226, 3-4=-3643/2538, 4-6=-2743/2028, 6-7=2659/2138, 7-8=-2150/1741,
8-9=-2201/1729, 9-11=-4966/3391, 11-12=-5723/3945
BOT CHORD 19-20=-3576/5756,18-19=-2106/3488,6-18=-208/264,16-17=-290/428,
15-16=-1215/2187, 14-15=-2707/4426, 13-14=3464/5218, 12-13=3463/5204,
2-20=-3812/6209
WEBS 3-19=-2284/1480,4-19=-240/581,4-18=-1147/781,16-18=-939/1774,7-18=904/1395,
7-16=-998/589, 7-15=-388/421, 9-15=-2940/2095, 11-14=867/692, 8-15=112311489,
9-14=-1503/2535, 3-20=-762/1429
NOTES-
1) Unbalanced roof live loads have been considered for this design.
This Item has been
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
electronically signed and
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterjor(2E)-1-4-13 to 2-9-12, Interior(1) 2-9-12 to 22-0-0, Exterior(2R)
sealed by Velez, Joaquin, PE
22-0-0 to 28-2-11, Interior(1) 28-2-11 to 44-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
using a Digital Signature.
plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
Printed copies of this
to the use of this truss component.
document are not considered
4rAII plates are MT20 plates unless otherwise indicated.
signed and sealed and the
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Signature must be Verified
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
on any electronic copies.
will fit between the bottom chord and any other members.
Joaquin Velez PE No.68182
7* Refer to girder(s) for truss to truss connections.
MiTek USA, Inc, FL Cert 6634
8) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
6904 Parke East Blvd. Tampa. FL 33610
capacity of bearing surface.
Date:
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1155 lb uplift at joint 2 and 1031 lb uplift
at joint 12.
February 10,2021
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
°
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSbTPl1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
T22789543
77283
A7
Hip
1
1
Job Reference (optional)
Chambers Trkiss, Inc., ' Fort Pierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:04:58 2021 Page 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-FGSw41 hyUVwrtYsV_5Cb1 ED4u8FVbinn UG6UCFzmazZ
�1 4 q 2-8-0 8 8 0 14 8-0 17-0-0 19 8 8 24-3-8 30-2-0 3q $ 8 37-1-9 44-0-0
�-0 2 8 0 6-0 0 2 4 0 2 8 8 4-7-0 5-10 8 0 &8 6-5-0 6-10-7
Scale = 1:82.9
5x8 =
6.00 F12
5x6 =
3x4 II 4x5 = 18 1 1
412
5x12 = 4x8 = 3.00 F12 4x10
4x12 4 � 3x4 II 4x4 II
1ox14 MT18HS
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/rP12014
CSI.
TC 0.67
BC 0.73
WB 0.95
Matrix -MS
DEFL. in
Vert(LL) -0.45
Vert(CT) -0.84
Horz(CT) 0.50
Wind(LL) 0.68
(loc) I/defl Lid
14 >999 360
14 >628 240
12 n/a n/a
14 >780 240
PLATES
MT20
MT18HS
Weight: 305 lb
GRIP
2441190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-7-2 oc purlins.
BOT CHORD 2x6 SP 240OF 2.OE *Except*
BOT CHORD
Rigid ceiling directly applied or 4-5-4 oc bracing.
2-22: 2x4 SP M 30, 6-18: 2x4 SP No.3, 17-18,14-17: 2x6 SP No.2
WEBS
1 Row at midpt 3-20, 4-19, 6-16, 9-15
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 12=Mechanical
Max Harz 2=489(LC 11)
Max Uplift 2=-1155(LC 12), 12=-1031(LC 12)
Max Grav 2=1705(LC 1), 12=1627(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-6366/4371, 3-4=-3640/2627, 4-6=-2748/2120, 6-7=-2238/1878, 7-8=-2224/1898,
8-9=-2552/2027, 9-11=-4950/3485, 11-12=-5751/4080
BOT CHORD 20-21=-3703/5712, 19-20=-2186/3450, 6-19=-329/609, 17-18=-223/377, 16-17=-219/384,
15-16=-1134/2027, 14-15=-2801/4392, 13-14=-3612/5260, 12-13=3599/5238,
2-21=-3947/6159
WEBS 3-20=-2278/1528, 4-20=-247/577, 4-19=-1124/771, 16-19=-1294/2096, 6-16=-899/727,
7-16=-282/329, 7-15=-370/683, 8-15=616/851, 9-15=-2721/1992, 9-14=-1532/2485,
11-14=-957/764, 3-21=-788/1411
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
This item has been
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 2-9-12, Interior(1) 2-9-12 to 19-8-8, Exterior(2E)
19-8-8 to 24-3-8, Exterior(2R) 24-3-8 to 30-6-3, Interior(1) 30-6-3 to 44-0-0 zone;C-C for members and forces & MWFRS for
electronically signed and
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
sealed by Velez, Joaquin, PE
3) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
using a Digital Signature.
to the use of this truss component.
Printed copies Of this
P
4) Provide adequate drainage to prevent water ponding.
5) All plates are MT20 plates unless otherwise indicated.
document are not Considered
6rThis truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Signed and Sealed and the
7) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
signature must be verified
will fit between the bottom chard and any other members.
electronic
On any el@CtrOf11C Copies.
is C
8) Refer to girder(s) for truss to truss connections.
Joaquin Velez No 2
No.68L.Cert
9) Bearing at joint(s) 2 considers parallel to grain value using ANSI/rPI 1 angle to grain formula. Building designer should verify
MiTek USA, Inc. 8 34
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1155 lb uplift at joint 2 and 1031 lb
8904 Parke East Blvd. Tampa FL 33610
uplift at joint 12.
Date:
February 10,2021
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. f'
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not p`
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
T22789544
77283
AS
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., t Fort Pierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:04:59 2021 Page 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-jS01HNiaFp2iUiRiYpjgZSmGFYbUK9Jvjwrl khzmazY
r1-4-01 2-8-0 8-8-0 + 14-8-0 17-8-8 22.0.0 26.3-8 30-2-0 i32-0-8 36-10-5 3i7-9-Q 440.0 i
1-40 2-&0 6-0.0 6-0.0 4-3-8 3.10-8 1.70.8 4-9-12 -11 6-2-7
d
5x6 =
6.00 12
3x4 = 5x6 =
31 8 32 9
Scale = 1:79.0
3x4 II 4x5 = 19
7x8 = 4x8 = 3.00 12 4x10 ZZ
4x12 10x14 MT18HS 3x4 I I 4x8 % 4x4 11
4.00 F12
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/TPI2014
CSI.
TC 0.63
BC 0.75
WB 0.93
Matrix -MS
DEFL. in
Vert(LL) -0.44
Vert(CT) -0.82
Horz(CT) 0.49
Wind(LL) 0.66
(loc) I/defl Lid
15 >999 360
15 >643 240
13 n/a n/a
15 >798 240
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 306 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-7-12 oc purlins.
BOT CHORD 2x6 SP 240OF 2.OE *Except*
BOT CHORD
Rigid ceiling directly applied or 4-5-1 oc bracing.
2-23: 2x4 SP M 30, 6-19: 2x4 SP No.3, 18-19,15-18: 2x6 SP No.2
WEBS
1 Row at midpt 3-21, 4-20, 7-20, 8-17, 10-16, 7-17
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 13=Mechanical
Max Horz 2=442(LC 11)
Max Uplift 2=-1155(LC 12), 13=-1031(LC 12)
Max Grav 2=1705(LC 1). 13=1627(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-6330/4419, 3-4=-3640/2666, 4-6=2750/2146, 6-7=2699/2326, 7-8=-2016/1793,
8-9=-2661/2161,9-10=-3009/2348,10-12=-4928/3521,12-13=-5742/4102
BOT CHORD 21-22=-3738/5646, 20-21=-2223/3411, 6-20=-308/405, 18-19=-249/291, 17-18=-239/297,
16-17=-1492/2458, 15-16=-2820/4366, 14-15=-3629/5247, 13-14=-3616/5227,
2-22=-3989/6089
WEBS 3-21=-2250/1525, 4-21=-245/564, 4-20=-11221797, 17-20=-961/1756, 7-20=96111215,
8-17=-846/599,B-16=-263/628,9-16=862/1153,10-16=2501/1874,10-15=1572/2448,
3-22=-805/1399, 12-15=-964/764, 7-17=-195/295
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
This item has been
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 2-9-12, Interior(1) 2-9-12 to 17-8-8, Exterior(2R)
17-8-8 to 23-11-3, Interior(1) 23-11-3 to 26-3-8, Exterior(2R) 26-3-8 to 32-6-3, Interior(1) 32-6-3 to 44-0-0 zone;C-C for members and
electronically signed and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
sealed by Velez, Joaquin, PE
3) Building Designer/ Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
using a Digital Signature.
to the use of this truss component.
Printed Copies Of this
4) Provide adequate drainage to prevent water ponding.
5) All plates are MT20 plates unless otherwise indicated.
document are not considered
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Signed and Sealed and the
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
signature must be verified
will fit between the bottom chord and any other members.
on any electronic copies.
8) Refer to girder(s) for truss to truss connections.
Joaquin Velez PE No.68182
3) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
MiTek USA, Inc. FL Cart 6634
capacity of bearing surface.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1155 lb uplift at joint 2 and 1031 lb
6904 Parke East Blvd. Tampa FL 33910
Date:
uplift at joint 13.
February 10,2021
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIYFP/1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789545
77283
A9
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., 0 Fort Pierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:05:00 2021 Page 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-BeahUjiCO6AZ6sOu6 WF36fJQ2yvC3b_2yabaH7zmazX
Tl 4 Q 8-1 8 15 8-8 �7-0 Q 22-7-12 28-3-8 i30-2-0 35-11-1 3fj 10r5 44-0-0
M-0 8-1-8 7-7-0 -3-8 , 5-7-12 5-7-12 1-10 8 5-9-1 0-11 4 7-1-11
6.00 12
Scale = 1:79.0
5x6 =
3x4 = 3x4 = 5x6 =
4x8
5 6 287 8 9
20 18 17
4x5 = 3x4 II 4x8 6x8 —_7x8 — 3.00 F12 4x10
4x4 I I
28-3.8
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/TPI2014
CSI.
TC 0.63
BC 0.78
V 0.97
Matrix -MS
DEFL. in (loc) I/defl Ud
Vert(LL) -0.42 14 >999 360
Vert(CT) -0.79 13-14 >670 240
Horz(CT) 0.38 12 n/a n/a
Wtnd(LL) 0.63 14 >833 240
PLATES GRIP
MT20 244/190
Weight: 283 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 2-8-5 oc purlins.
BOT CHORD 2x6 SP No.2 *Except` BOT CHORD
Rigid ceiling directly applied or 4-5-4 oc bracing.
12-14: 2x6 SP 240OF 2.0E WEBS
1 Row at midpt 3-18
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 12=Mechanical
Max Horz 2=394(LC 11)
Max Uplift 2=-1155(LC 12). 12=-1031(LC 12)
Max Grav 2=1705(LC 1), 12=1627(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3173/2315, 3-5=-2494/1942, 5-6=2153/1865, 6-7=-2825/2302, 7-8=3300/2545,
8-9=-3695/2834, 9-11 =-4918/3496, 11-12=-5746/4105
BOT CHORD 2-20=-1943/2903, 18-20=-1943/2903, 17-18=-1335/2153, 16-17=-1373/2224,
15-16=-1834/2926,14-15=-2781/4346,13-14=-3642/5249,12-13=3627/5231
WEBS 3-20=0/349, 3-18=886/694, 5-18=4991711, 6-17=-834/577, 6-16=-68211069,
7-16=-820/643, 7-15=-352/686, 8-15=-119511528, 9-14=1533/2386, 11-14=975/776,
9-15=-2365/1800
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 15-8-8, Exterior(2R)
This item has been
15-8-8 to 21-11-3, Interior(1) 21-11-3 to 28-3-8, Exterior(2R) 28-3-8 to 34-6-3, Interior(1) 34-6-3 to 44-0-0 zone;C-C for members and
DOL=1.60
electronically signed and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
sealed by Velez, Joaquin, PE
to the use of this truss component.
using a Digital Signature.
4) Provide adequate drainage to prevent water ponding.
Printed copies Of this
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
document are not considered
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
Signed and Sealed and the
7) Refer to girder(s) for truss to truss connections.
signature must be verified
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1155 lb uplift at joint 2 and 1031 lb uplift
on any electronic copies.
at joint 12.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tarrl 33610
Date:
February 10,2021
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. '
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage, For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789546
77283
ATA
ATTIC
1
1
Job Reference (optional)
Cnambers Russ, Inc., A fort tierce, rL o.anu s NOV au zuzu ml I eK inaustries, Inc. vvea reD iu ua:uo:uz zucl rage I
ID:luptf?XWOPbi2TquAJrztDzmxuU-81 iRvOkSYkQHLAAH DxHXB4Om PmZEXWgLPl4hLOzmazV
T1 4 Q 5-10-0 11-10-4 93-0-Q 19-1-12 25-0-14 31-0-0 33-10-0 , 37-5-4 41-4-0 44-0-0 45-0-Q
-4-0 5-10-0 6. _4
1-1-1 6-1-12 5-11-2 5-11-2 2_10-0 3-7-4 3_10_12 ` 2-8-0
5x8 =
6.00 12 8x10 :-
4 538 39
3x4 =4x6 = 3x4 = 5x6 =
40 6 7 8 41 9 42
Scale = 1:79.0
26 — 24 23 21 '- 20 19 3x4 - -
4x6 = 3x4 II 5x8 MT18HS z7-0-0 3x4 II 7x8 WB = 4x4 = 4x12 = 4x4 II 3x4 II Sx10 = 6x1D =
4.00 112
6x8 = 10x10 =
31-0-0
Plate Offsets (X,Y)-- [2:0-1-4,0-0-3], [3:0-3-0,0-3-0], [4:0-5-0,0-3-4], [5:0-5-12,0-2-4], [7:0-3-0,Edge], [9:0-3-0,0-2-0], [12:0-3-O,Edge],
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TCLL
20.0
Plate Grip DOL
1.25
TC 0.63
Vert(LL)
-0.62 21-23 >847 360
MT20 244/190
TCDL
7.0
Lumber DOL
1.25
BC 0.93
Vert(CT)
-1.03 21-23 >513 240
MT18HS 244/190
BCLL
0.0
Rep Stress Incr
YES
WB 0.96
Horz(CT)
0.24 13 n/a n/a
BCDL
10.0
Code FBC2020/TP12014
Matrix -MS
Wind(LL)
0.60 21-23 >879 240
Weight: 316 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 2-5-7 oc purlins.
BOT CHORD 2x6 SP 240OF 2.OE *Except*
BOT CHORD Rigid ceiling directly applied or 6-9-7 oc bracing. Except:
10-19,13-27: 2x4 SP M 30
2-2-0 oc bracing: 13-15
WEBS
2x4 SP No.3 *Except*
WEBS
1 Row at midpt
6-21, 8-20, 29-30
4-24: 2x4 SP M 30
JOINTS
1 Brace at Jt(s): 30
OTHERS
2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 13=0-8-0
Max Horz 2=340(LC 11)
Max Uplift 2=-999(LC 12), 13=1069(LC 12)
Max Grav 2=2435(LC 18), 13=2302(LC 19)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4695/1992, 3-4=-4307/1830, 4-5=-2501/988, 5-6=-3974/1813, 6-8=-3823/1973,
8-9=-3197/1742, 9-10=-4339/2318, 10-11=-4378/2219, 11-13=-5694/2774
BOT CHORD 2-26=-1606/4389, 24-26=-160914388, 23-24=-1300/4006, 21-23=-1307/4026,
20-21 =-1 480/3849, 19-20=368/778, 17-18=-2271/4928, 15-17=-2219/4817,
15-16=-159/348,13-15=-2309/4969
WEBS 3-24=-464/393, 24-28=-298/1013, 4-28=-287/948, 23-29=291/293, 6-29=489/469,
6-21=-303/245,8-21=0/542, 8-20=1132/382, 9-20=-11/421,18-20=-906/2415,
9-18=-908/1637, 28-30=-766/312, 29-30=-1677/956, 5-30=-320/680, 4-30=1407/833,
11-18=-1398/754, 16-17=-161/563, 11-16=-347/994, 5-29=-961/1896
NOTES-
This item has been
1) Unbalanced roof live loads have been considered for this design.
electronically signed and
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; cat.
sealed by Velez, Joaquin, PE
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 13-0-0, Exterior(2R)
using a Digital Signature.
13-0-0 to 19-1-12, Interior(1) 19-1-12 to 31-0-0, Exterior(2R) 31-0-0 to 37-5-4, Interior(1) 37-5-4 to 45-4-13 zone;C-C for members
Printed copies of this
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
document are not considered
'to the use of this truss component.
signed and sealed and the
4) 150.01b AC unit load placed on the top chord, 15-6-0 from left end, supported at two points, 4-0-0 apart.
signature must be verified
5) Provide adequate drainage to prevent water ponding.
on any electronic Copies.
6) All plates are MT20 plates unless otherwise indicated.
Joaquin Velez PE No.68182
7j This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
MiTek USA, Inc. FL Cart 8834
8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
6904 Parke East Blvd. Tampa FL 33810
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
Date:
9) Ceiling dead load (5.0 psf) on member(s). 28-30, 29-30
10) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 23-24
February 10,2021
A WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verily the applicability of design parameters and property Incorporate this design into the overall Not
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
I
s always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suae 203 Waldorf, MO 20501 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789546
77283
ATA
ATTIC
1
1
Job Reference (optional)
Chambers Truss, Inc., A Fort Pierce, FL
8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:05:02 2021 Page 2
ID:luptf?XWOPbi2TquAJrztDzmxuU-81 iRvOkSYkQHLAAHDxHXB4OmPmZEXWgLPt4hLOzmazV
NOTES-
11) Bearing at joint(s) 13 considers parallel to grain value using ANSUTPI 1 angle to grain formula. Building designer should verify capacity of bearing surface.
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 999 lb uplift at joint 2 and 1069 lb uplift at joint 13.
13) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
'
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPif Quality Criteria, OSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789547
77283
ATB
ATTIC
1
1
Job Reference (optional)
Chambers Truss, Inc., � Fort Pierce, FL
8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:05:03 2021 Page 1
ID:lupff7XWOPbi2TquAJrztDzmxuU-cDGp7kl4J 1 Y7zJITneomklxx49vKGyrVeXgEtSzmazU
14-7-11
rt-0-0 6.2.6 11-10-4 13-2-11 15rq-0 19-1-12 240-14 , 29-0.0 i 33-10.0 37-5.4 , _ 41.4.0 i _ 44-0
-41 0 6.2-6 5.7-14 -3-1 0-4-5 4-1-12 4-11-2 4-11-2 4.10.0 3-7-4 3-10.12 2-8-0
1.5-11
Scale = 1:79.0
6x8 =
6.00 F12 5x6 =
37 7 38 8 39 40 9 10
26 '_ 24 23 '- 21 20 '-
4x8 = 7-0-0 5x8 = BAD = 6x10 =
7x8 WB = x4 = 6x8 = 7x10 =
4.00112
4x4 =
6-2.6
37-5-4
414-0 , 44-0.0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020frP12014
CSI.
TC 0.64
BC 0.94
WB 0.96
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) Udefl Ud
-0.49 21-23 >999 360
-0.75 21-23 >704 240
0.26 14 n/a n/a
0.39 23-24 >999 240
PLATES GRIP
MT20 2441190
Weight: 315 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 2-5-3 oc purlins.
BOT CHORD 2x6 SP No.2 *Except*
BOT CHORD Rigid ceiling directly applied or 5-8-4 oc bracing. Except:
16-19,22-25,14-17: 2x6 SP 240OF 2.OE, 14-27:
2x4 SP M 30
2-2-0 oc bracing: 14-16
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 9-23, 9-21, 10-19
OTHERS 2x4 SP No.3
JOINTS
1 Brace at Jt(s): 29
REACTIONS. (size) 2=0-8-0, 14=0-8-0
Max Horz 2=-388(LC 10)
Max Uplift 2=-966(LC 12), 14=-1051(LC 12)
Max Grav 2=2474(LC 18), 14=2327(LC 19)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4906/1974, 3-5=-4100/1641, 5-6=-3693/1572, 6-7=1622/662, 7-8=-3515/1641,
8-9=-3616/1649, 9-10=-3087/1642, 10-11=-4391/2324, 11-13=-4421/2167,
13-14=-5770/2712
BOT CHORD 2-26=-1590/4623, 24-26=-1590/4623, 23-24=-1075/3771, 21-23=-1180/3433,
20-21=-454/1062,11,-19=-237/353,18-19=-2213/4993,16-18=-2162/4882,
16-17=-158/351,14-16=-2253/5035
WEBS 3-26=-46/348, 3-24=-968/597, 5-24=1881726, 23-28=-116/354, 8-28=-337/232,
9-23=-57/582, 9-21=-820/242, 10-21=48/649, 19-21=-638/1934, 10-19=-913/1485,
6-29=-2303/1121, 28-29=-2292/1121, 7-28=-1130/2270, 13-19=-1411/715,
17-18=-170/589, 13-17=-353/1024
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 15-0-0, Exterior(2R)
15-0-0 to 21-2-11, Interior(1) 21-2-11 to 29-0-0, Exterior(2R) 29-0-0 to 35-2-11, Interior(1) 35-2-11 to 45-4-13 zone;C-C for members
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
4)�200.01b AC unit load placed on the top chord, 15-6-0 from left end, supported at two points, 4-0-0 apart.
5) Provide adequate drainage to prevent water ponding.
6) All plates are 3x4 MT20 unless otherwise indicated.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
9) Ceiling dead load (5.0 psf) on member(s). 5-6, 6-29, 28-29
10) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 23-24
11) Bearing atjoint(s) 14 considers parallel to grain value using ANSIIrPI 1 angle to grain formula. Building designer should verify
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
Corg'dFtpftl,P§&9y design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MTek& connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPlf Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789547
77283
ATB
ATTIC
1
1
Job Reference (optional)
Chambers TILss, Inc., ' Fort Pierce, FL
6.43U S NOV 3U ZUZU mi i eK maustfles, Inc. vvea t-eD l u ud:uo:u4 xuzi rage z
ID:I uptf?X WOPbi2TquAJrztDzmxuU-4QgBK41j4 Lh_bTJfLMJ?GVT6pZFZ?P5es BZoQuzmazT
NOTES-
- 12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 966 lb uplift at joint 2 and 1051 lb uplift at joint 14.
13) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use onlywith MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/7P/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789548
77283
ATC
ATTIC
1
1
Job Reference (optional)
Chambers Truss, Inc., % Fort Pierce, FL
8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:05:05 2021 Page 1
I D:luptf?XWO P bi2TquAJ rztDzm xuU-YcOaYQ m LrfprCduru3q EpjOHbzbOktfo5rJ LyLzmazS
14-7-11
1.4-0 5:16 11.10-4 13.2- 17-0-0 19-1-12 27-0-0 32-5-13 37-11-11 440-0
1-4057-14 -3.1 2-45 2-1-12 7-10-4 SS13 SS13 6-11-1
1-511
Scale = 1:77.2
5x12 =
6.00 12 5x8 =
7 31 8 32 33 9
48 = 20 1r9 7-0-0 117 '"'" 16 5x8 = _- 4x4 = 06 =
5x8 MT18HS = 4x8 =
4x4 =
6-2-6 11-10-4
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020lrP12014
CSI.
TC 0.64
BC 0.93
WB 0.94
Matrix -MS
DEFL,
Vert(LL)
Vert(CT)
Horz(CT)
WMd(LL)
in (loc) Ildefl Ud
-0.33 17-19 >999 360
-0.57 17-19 >925 240
0.15 13 rile n/a
0.33 19 >999 240
PLATES GRIP
MT20 244/190
MT18HS 2441190
Weight: 291 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 2-11-2 oc purlins.
BOT CHORD 2x6 SP No.2 `Except*
BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
15-18: 2x6 SP 240OF 2.0E
WEBS
1 Row at midpt 9-21, 10-16, 6-21, 16-21
WEBS 2x4 SP No.3
JOINTS
1 Brace at Jt(s): 21
REACTIONS. (size) 2=0-8-0, 13=Mechanical
Max Horz 2=424(LC 11)
Max Uplift 2=-968(LC 12), 13=-928(LC 12)
Max Grav 2=2473(LC 18), 13=221O(LC 19)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4883/1973, 3-5=-4151/1657, 5-6=3703/1597, 6-7=1804/742, 7-8=-2172/1138,
8-9=-2178/1145, 9-10=-3202/1661, 10-12=-4139/2055, 12-13=-4343/2155
BOT CHORD 2-20=-1672/4620, 19-20=-1672/4620, 17-19=-1179/3834, 16-17=-1179/3835,
14-16=-1425/3258, 13-14=-1802/3832
WEBS 3-20=-32/283, 3-19=-893/559, 5-19=-156/754, 17-21=0/705, 8-21=-463/484,
9-21=-12201654, 9-16=-487/1407, 10-16=-836/618, 10-14=-301/720, 12-14=375/397,
6-22=-2608/1124, 21-22=-2600/1123, 7-21=-620/940, 16-21=-1318/232
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 17-0-0, Exterior(2R)
17-0-0 to 23-2-11, Interior(1) 23-2-11 to 27-0-0, Exterior(2R) 27-0-0 to 33-2-11, Interior(1) 33-2-11 to 43-11-4 zone;C-C for members
This item has been
and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
electronically signed and
to the use of this truss component.
sealed by Velez, Joaquin, PE
4) 200.01b AC unit load placed on the top chord, 15-6-0 from left end, supported at two points, 4-0-0 apart.
using a Digital Signature.
5) Provide adequate drainage to prevent water ponding.
Printed Copies of this
6) All plates are MT20 plates unless otherwise indicated.
7) All plates are 3x4 MT20 unless otherwise indicated.
document are not Considered
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
signed and Sealed and the
9) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
signature must be verified
will fit between the bottom chord and any other members, with BCDL = IO.Opsf.
on any electronic Copies.
10) Ceiling dead load (5.0 psf) on member(s). 5-6, 6-22, 21-22
Joaquin Velez PE No.68182
1y) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 17-19
MiTek USA, Inc. FL Cert 8634
12) Refer to girder(s) for truss to truss connections.
13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 968 lb uplift at joint 2 and 928 lb uplift
6904 Parke East Blvd. Tampa FL 33610
at joint 13.
Date:
14) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
February 10,2021
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qly
Ply
T22789549
77283
ATD
ATTIC
1
1
Job Reference (optional)
Chambers Tfuss, Inc., ' Fort Pierce, FL
a
19
4x8 = 3x4 11
6-2-6 11-10-4
8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:05:06 2021 Page 1
I D:I uptf?X WOPb i2TquAJ rztDzmxu U-Ooxylm nzcyxignT2 Sn LTLwZRGNxuTNXxKV2vU nzmazR
14-7-11 19-1-12
1-4-0 6-2-6 11-10-4 13-2- '16-0-0 19-0-0 25-0-0 31-1-13 37-3.11 44.0.0
1-40 6-2.6 5-7-14 -3-1 1-4-5 3.0.0 0.1.12 5-10-4 6-1-13 6-1.13 6-8-5
1-5.11
Scale = 1:77.2
5x6 =
5x8 =
6.00 12
28 7 8
18
5x8 MT18HS =
4x4 =
19-1-12
16 ,... 15
3x4 II 4x8 = 5x8 = 4x4 =
4x6 =
3x4 II
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/TP12014
CS1.
TC 0.64
BC 0.95
WB 0.71
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) 1/defl Lid
-0.35 16-18 >999 360
-0.60 16-18 >877 240
0.15 12 n/a n/a
0.35 18 >999 240
PLATES GRIP
MT20 244/190
MT18HS 244/190
Weight: 287lb FT=20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
Structural wood sheathing directly applied or 2-11-11 oc purlins.
BOT CHORD 2x6 SP No.2 'Except' BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
14-17: 2x6 SP 240OF 2.0E WEBS
1 Row at midpt 15-20, 8-15, 9-15, 8-20
WEBS 2x4 SP No.3
2 Rows at 1/3 pts 6-20
JOINTS
1 Brace at Jt(s): 20
REACTIONS. (size) 2=0-8-0, 12=Mechanical
Max Harz 2=471(LC 11)
Max Uplift 2=-968(LC 12), 12=-928(LC 12)
Max Grav 2=2473(LC 18), 12=2213(LC 19)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-4885/1966, 3-5=-4145/1648, 5-6=-3705/1596, 6-7=-1700/789, 7-8=-1402/753,
8-9=-2989/1573, 9-11=-4063/2012, 11-12=4294/2123
BOT CHORD 2-19=-1664/4657, 18-19=-1664/4657, 16-18=-1175/3867, 15-16=-1173/3863,
13-15=-1340/3127, 12-13=-1760/3781
WEBS 3-19=-40/291, 3-18=-898/556, 5-18=-137/734, 16-20=-2/684, 7-20=-173/454,
15-20=-1761/469, 8-15=-734/1890, 9-15=-956/688, 9-13=-331/828, 11-13=-420/438,
6-20=-2827/1108, 8-20=-1846/890
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 3-0-0, Interior(1) 3-0-0 to 19-0-0, Exterior(2E)
19-0-0 to 25-0-0, Exterior(2R) 25-0-0 to 31-1-13, Interior(1) 31-1-13 to 43-11-4 zone;C-C for members and forces & MWFRS for
This item has been
reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
electronically signed and
to the use of this truss component.
sealed by Velez, Joaquin, PE
4) 200.01b AC unit load placed on the top chord, 15-6-0 from left end, supported at two points, 4-0-0 apart.
using a Digital Signature.
5) Provide adequate drainage to prevent water ponding.
Printed copies of this
6) All plates are MT20 plates unless otherwise indicated.
7� This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
document are not Considered
8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
signed and sealed and the
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
Signature must be Verified
9) Ceiling dead load (5.0 psf) on member(s). 5-6, 6-20
on any electronic copies.
10) Bottom chord live load (40.0 psf) and additional bottom chord dead load (5.0 psf) applied only to room. 16-18
Joaquin Velez PE No.68182
11) Refer to girder(s) for truss to truss connections.
MiTek USA, Inc. FL.Cert 6634
12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 968 lb uplift at joint 2 and 928 lb uplift
6904 Parke East Blvd. Tampa.FL 33810
at joint 12.
Date:
13) ATTIC SPACE SHOWN IS DESIGNED AS UNINHABITABLE.
February 10,2021
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design.parameters and properly incorporate this design into the overall p�
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
iTek�
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789550
77283
B
Hip
1
1
Job Reference (optional)
Chambers T:uss, Inc., ' Fort Pierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:05:07 2021 Page 1
ID: luptf?XWOPbi2TquAJrztDzmxuU-U?VKy6obNG3ZSx2EOUliuB5genNXCyz4Z9oSODzmazQ
1 4-0 6-3-8 9-0-0 16-2-0 23 4-0 2611 32.4-0 i 33 8
14-0 6-3_8 9101 7-2-0 7-2-0 2-8-8 6-3-8 14-0
3x5 =
4x5 =
3x8 =
4x5 =
7 23 24 0 25 26 6
4x6 =
3x8 =
2x3 II
23-4-0
3x8 =
4x6 =
Scale = 1:57.4
3x5 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/TPI2014
CSI.
TC 0.41
BC 0.48
WB 0.25
Matrix -MS
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in (loc) I/deft Ud
-0.14 10-20 >999 360
-0.30 10-20 >999 240
0.08 8 n/a n/a
0.18 12 >999 240
PLATES GRIP
MT20 244/190
Weight: 159 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 4-7-14 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 6-3-8 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 5-14, 5-10
REACTIONS. (size) 2=0-8-0, 8=0-8-0
Max Horz 2=231(LC 11)
Max Uplift 2=-879(LC 12), 8=-879(LC 12)
Max Grav 2=1272(LC 1), 8=1272(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2182/1610, 3-4=-1984/1516, 4-5=1753/1404, 5-6=-1753/1404, 6-7=1984/1516,
7-8=-2182/1610
BOT CHORD 2-14=-1252/1924, 12-14=-1377/2184, 10-12=-1377/2184, 8-1 0=-1 289/1912
WEBS 3-14=-330/368, 4-14=-447/656, 5-14=-608/407, 5-10=-608/408, 6-10=-447/656,
7-10=-331/368
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=32ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-14-13 to 1-10-0, Interior(1) 1-10-0 to 9-0-0, Exterior(2R)
9-0-0 to 13-6-14, Interior(1) 13-6-14 to 23-4-0, Exterior(2R) 234-0 to 27-10-14, Interior(1) 27-10-14 to 33-8-13 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
This Item has been
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads,
electronically Signed and
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
sealed by Velez, Joaquin, PE
will fit between the bottom chord and any other members.
using a Digital Signature.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 879 lb uplift at joint 2 and 879 lb uplift at
Printed copies of this
joint 8.
document are not considered
'
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date;
February 10,2021
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. '
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and prop edy incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789551
77263
B1
Hip
1
1
Job Reference (optional)
Chambers Truss, Inc., ' Fort Pierce, FL 8.430 s Nov 30 2020 Mtl eK Industries, Inc. Wed Feb 1U UU:Ub:U6 2U21 Hage 1
I D:I uptf?XWOPbi2TquAJ rztDzmxuU-yB3iASpD BaBQ35dQaC OxR Les WAlrxMyEnpX?Zgzm azP
14-0 5-9-4 11-0-0 16-2-0 214-0 26-6-12 32-4-0 33-M
1-4-0 5-9 4 5-2-12 5-2-0 5-2-0 5-2-12 5-9 4 1 4-0
4x8 = 2x3 II 4x8 =
4 25 265 27 28 6
2x3 II 'J 34 =
3x4 = 3x4 =
11-0-0
3x8 =
3x4 = 2x3 II
3x6 =
32-4-0
Scale = 1:57.4
3x4 =
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/TPI2014
CSI.
TC 0.34
BC 0.35
WB 0.39
Matrix -MS
DEFL. in (loc) I/deft Ud
Vert(LL) -0.10 13 >999 360
Vert(CT) -0.19 11-13 >999 240
Horz(CT) 0.08 8 n/a n/a
Wind(LL) 0.15 13 >999 240
PLATES GRIP
MT20 244/190
Weight: 174 lb FT = 20%
LUMBER-
BRACING.
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-9-6 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 6-4-2 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 8=0-8-0
Max Horz 2=275(LC 11)
Max Uplift 2=-879(LC 12), 8=-879(LC 12)
Max Grav 2=1272(LC 1), 8=1272(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-2271/1642, 3-4=-1822/1404, 4-5=-1762/1473, 5-6=-1762/1473, 6-7=-1822/1404,
7-8=-2271/1642
BOT CHORD 2-16=-1296/2047, 15-16=-1296/2047, 13-15=-904/1575, 11-13=-924/1575,
10-11=-1333/1982, 8-1 0=-1 333/1982
WEBS 3-15=-560/471, 4-15=-196/375, 4-13=-222/383, 5-13=-314/336, 6-13=-222/383,
6-11=-196/375, 7-11=-561/471
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=32ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-10-0, Interior(1) 1-10-0 to 11-0-0, Exterior(2R)
11-0-0 to 15-6-14, Interior(1) 15-6-14 to 21-4-0, Exterior(2R) 21-4-0 to 25-10-14, Interior(1) 25-10-14 to 33-8-13 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
This item has been
to the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
electronically signed and
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
sealed by Velez, Joaquin, PE
6) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members.
Printed copies of this
p
7) Provide mechanical connection (by others) of truss to bearing plate Capable of withstanding 879 lb uplift at joint 2 and 879 lb uplift at
document are not considered
joint 8.
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 8834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. r`
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not I`
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTek"
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPII Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
ty
Ply
T22789552
77283
D
HALF HIP
1
1
Job Referenceo (optional)
Chambers Tress, Inc., Fort Rierce, FL 8,430 s Nov 30 2020 MITeK industries, Inc. wea t-eD 10 14:39:3b 2021 rage 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-IGoX1_?p7rkZp6J2KpKPbv9wR7w9hsfl MFytljzm Wy6
-11
0 7-0-0 11-2-4 15-8-0
10 7-0-0 4-24 4-5-12
5x6 =
3 13
Scale = 1:29.0
3x4 = 3x4 II
4 14 15 5
3x4 = 6x8 =
Plate Offsets (X Y)— [2:0-0-12 Edge] [3:0-3-0 0-2-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.49
Vert(LL) 0.24 6-7 >768 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.36
Vert(CT) -0.21 6-7 >903 240
BCLL 0.0
Rep Stress Incr YES
WB 0.39
Horz(CT) -0.02 6 n/a n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix -MS
Weight: 75 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-14 oc bracing.
REACTIONS. (lb/size) 2=653/0-8-0, 6=571/0-8-0
Max Horz 2=281(LC 12)
Max Uplift 2=-808(LC 12), 6=-740(LC 9)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-11=-841/1139, 11-12=-787/1143, 3-12=-764/1159, 3-13=-684/1164, 4-13=684/1164
BOT CHORD 2-16=-1160/682, 16-17=-1160/682, 7-17=-1160/682, 7-18=-793/503, 18-19=793/503,
6-19=-793/503
WEBS 4-7=-510/285, 4-6=626/980
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 7-0-0, Exterior(2R) 7-0-0
to 11-2-4, Interior(1) 11-2-4 to 15-6-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members.
electronically signed and
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 808 lb uplift at joint 2 and 740 lb uplift at
sealed by Velez, Joaquin, PE
joint 6.
using a Digital Signature.
LOAD CASE(S) Standard
Printed copies of this
document are not considered
'
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 8834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
® WARNING -verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19I2D20 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall r
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
city
Ply
T22789553
77283
D1
HALF HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort aierce, FL 8,430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 14:41:54 2021 Page 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-k?i4CVg?NYEq?TRmzVK?kDPe59JXIIfUKN7j09zm Wvx
1 4-0 6-3-9 9-0-0 15-8-0
1 4-0 6-3-9 2-8-7 6-8-0
11
4x6 =
4x4 = ;5xo =
13 14 15
4x5 =
x6 II
Scale = 1:30.9
9-0-0
- 15-8-0
9-0-0
6-8-0 '
Plate Offsets (X Y)-- [2:0-0-4,Edgej
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.64
Vert(ILL) 0.45
7-10 >417 240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.56
Vert(CT) -0.25
7-10 >753 240
BCLL 0.0
Rep Stress Incr YES
WB 0.35
Horz(CT) -0.01
6 n/a n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix -MS
Weight: 80 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 cc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-24 cc bracing.
WEBS
1 Row at midpt 5-7
REACTIONS. (lb/size) 6=571/0-8-0, 2=653/0-8-0
Max Horz 2=343(LC 12)
Max Uplift 6=-741(LC 12), 2=-792(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-11=-820/1092, 11-12=-780/1094, 3-12=-711/1109, 3-4=-620/990, 4-13=514/905,
13-14=-514/905, 14-15=-514/905, 5-15=-514/905, 5-6=526/859
BOT CHORD 2-16=-1212/698, 16-17=-1212/698, 7-17=-1212/698
WEBS 3-7=-269/526, 5-7=1085/605
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 9-0-0, Exterior(2R) 9-0-0
to 13-2-15, Interior(1) 13-2-15 to 15-6-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
been
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has
will fit between the bottom chord and any other members.
electronically Signed and
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 741 lb uplift at joint 6 and 792 lb uplift at
sealed by Velez, Joaquin, PE
joint 2.
using a Digital Signature.
LOAD CASE(S) Standard
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE NoA8182
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
A WARNING - Vedly design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPlf Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789554
77283
D2
HALF HIP
2
1
Job Reference (optional)
Chambers Truss, Inc., ' Fort Pierce, FL 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 09:05:10 2021 Page 1
I D:luptf?XWOPbi2TquAJ rztDzmxuU-vaBTb7gTfB R8J OnphdQ P Wmj Ck—TsP FhXF706dYzm azN
1 4-0 5-94 11-0-0 15-8-0
1 4-0 5-9-4 5-2-12 4-&0
4x8 = 3x4 11 Scale = 1:35.7
4 14 15 5
3x4 = 2x3 11 3x4 = 6x8 =
5-9A 11-0-0 15-8-0
5-9-4 5-2-12 4-8-0
Plate Offsets (X,Y)— [4:0-5-4,0-2-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.36
Vert(LL) 0.12 B-11 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.25
Vert(CT) -0.06 8-11 >999 240
BCLL 0.0 '
Rep Stress Incr YES
WB 0.51
Horz(CT) -0.02 6 n/a n/a
BCDL 10.0
Code FBC2020rrPI2014
Matrix -MS
Weight: 89 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins,
BOT CHORD 2x4 SP M 30 except end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 5-9-8 oc bracing.
REACTIONS. (size) 2=0-8-0, 6=0-8-0
Max Horz 2=404(LC 12)
Max Uplift 2=-772(LC 12), 6=761(LC 12)
Max Grav 2=653(LC 1), 6=571(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-919/1391, 34=-451/604
BOT CHORD 2-8=-1514/774, 7-8=-1514/774, 6-7=-628/348
WEBS 3-8=-490/236, 3-7=-495/1028, 4-7=-683/380, 4-6=-540/984
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 11-0-0, Exterior(2E)
11-0-0 to 15-6-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific
to the use of this truss component.
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 772 lb uplift at joint 2 and 761 lb uplift at
electronically signed and
joint 6.
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 8634
8904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIMPH Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789555
77283
D3
HALF HIP
2
1
Job Reference (optional)
Chambers Tras, Inc., Fort Pferce, FL 8.4311 s Nov 3u 2u20 Mi i ex mcusmes, inc. Wed Feb W i4:92;23 202 i rage i
ID:luplf?XWOPbi2TquAJrztDzmxuU-Nay2HQ1 BYSujzw9LA5LoPK6emrFh2mzm?OemwzzmWvU
1 4-0 6-9-4 13-0-0 15-8-0
1 4-0 6-9-4 6-2-12 2 8-0
I
4x8 = 3x4 11 Scale = 1:40.1
5 19 6
3x4 = 2x3 11 3x4 = 6x8 =
Plate Offsets (X Y)-- 12:0-0-8 Edge] [5:0-5-4 0-2-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.45
Vert(LL) 0.19
9-12 >960 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.34
Vert(CT) -0.09
9-12 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.72
Horz(CT) -0.02
7 n/a n/a
BCDL 10.0
Code FBC2020/TP12014
Matrix -MS
Weight: 95 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-7-0 oc bracing.
REACTIONS. (lb/size) 2=653/0-8-0, 7=571/0-8-0
Max Harz 2=466(LC 12)
Max Uplift 2=-748(LC 12), 7=-785(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-13=-876/1273, 3-13=-814/1278, 3-4=-740/1292, 4-14=-301/312, 5-14=-214/333
BOT CHORD 2-16=-1480/728, 9-16=-1480/728, 9-17=-1480/728, 8-17=-1480/728, 7-8=-397/200
WEBS 4-9=-584/290, 4-8=609/1252, 5-8=-877/409, 5-7=-552/1102
NOTES -
I) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 13-0-0, Exterior(2E)
13-0-0 to 15-6-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
This Item has been
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 748 lb uplift at joint 2 and 785 lb uplift at
electronically signed and
joint 7.
sealed by Velez, Joaquin, PE
using a Digital Signature.
LOAD CASE(S) Standard
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 8634
6904 Parke East Blvd. Tampa. FL 33610
Date:
February 10,2021
A WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall piii��.���
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 'y'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the p/�giTek'
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPll Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789556
77283
D4
HALF HIP
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Rierce, FL Run: 8.420 s Sep 14 2020 Print: 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 14:43:12 2021 Page 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-R?PaaAdxO W3mMSPIXujlugeylby_l_EzGWOr7ezm Wuj
-1-4-0 7-10-0 15-0-0 {5-8-Q
1 4-0 7-10-0 7-2-0
1,
0
3x6 = 3x4 =
5
3x4 = 2x3 II 6x8 =
Scale = 1:44.8
7-10-0
15-8-0
7-10-0
7-10-0
Plate Offsets (X Y)-- [3:0-4-0 Edge] [4:0-3-0,0-2-0] [5:Edge,0-1-8]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.68
Vert(LL) 0.33
7-10 >572 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.48
Vert(CT) -0.15
7-10 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.46
Horz(CT) -0.02
6 n/a n/a
BCDL 10.0
Code FBC2020rTP12014
Matrix -MS
Weight: 80 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 5-2-12 oc bracing.
WEBS
1 Row at midpt 5-6. 3-6
REACTIONS. (lb/size) 2=653/0-8-0, 6=571/0-8-0
Max Horz 2=527(LC 12)
Max Uplift 2=-720(LC 12), 6=-813(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-11=-828/1128, 3-11=-757/1152, 5-6=-1871324
BOT CHORD 2-13=-1407/677, 7-13=-14071677, 7-14=1393/673, 14-15=-1393/673, 6-15=-1393/673
WEBS 3-7=-726/362, 3-6=743/1540
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
Il; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 15-0-0, Exterior(2E)
15-0-0 to 15-6-4 zone; porch left and right exposed;C-C for members and farces & MWFRS for reactions shown; Lumber DOL=1.60
plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
This item has been
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 720 lb uplift at joint 2 and 813 lb uplift at
electronically signed and
joint 6.
sealed by Velez, Joaquin, PE
LOAD CASE(S) Standard
using a Digital Signature.
Printed copies of this
document are not considered
'
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No,68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Data:
February 10,2021
®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall �a
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789557
77283
D5
MONOPITCH
6
1
Job Reference (optional)
Chambers Truss, Inc., Fort Fierce, FL Run: 8.420 s Sep i4 ZULU rani: 8.430 s Nuv uo 2020 rvu, ea inuu,, as, uw. V � .. , ae=
ID:luptf?XWOPbi2TquAJrztDzmxuU-R?PaaAdxOW3mMSPIXujlugeydby7l z5zG WOr7ezm Wuj
-1 4-0 7-11-8 15-8-0
1� 0 7-11-8 7-8-8
Scale = 1:44.6
I
3x4 = 2x3 11 6x8 =
Plate Offsets (X Y)-- [4:0-3-0 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL, in (loc) I/deft Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.69
Vert(LL) 0.35 7-10 >539 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.47
Vert(CT) -0.15 7-10 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.53
Horz(CT) -0.02 6 n/a n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix -MS
Weight: 81 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 4-11-3 oc bracing.
WEBS 1 Row at midpt 5-6,
3-6
REACTIONS. (lb/size) 2=653/0-8-0, 6=571/0-8-0
Max Horz 2=542(LC 12)
Max Uplift 2=-713(LC 12), 6=-821(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-11=-824/1209, 3-11=-752/1233, 5-6=-191/318
BOT CHORD 2-13=-1604/673, 7-13=-1604/673, 7-14=-1604/673, 6-14=-1604/673
WEBS 3-7=-738/362, 3-6=-749/1786
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=oft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 15-6-4 zone; porch left
and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 713 lb uplift at joint 2 and 821 lb uplift at
joint 6.
This item has been
LOAD CASE(S) Standard
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall 5�� AAr IYI
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chard members only. Additional temporary and permanent bracing iTek`
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITPlf Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789558
77283
D6
HALF HIP
1
1
0•
Job Reference o tional
Chambers Truss, Inc., Fort 91erce, FL Run: 8.420 s Sep 14 2020 Print: 8.430 s Nov 30 2020 MiTeK Industries, Inc. Wed Feb 10 14:43:13 2021 Page 1
ID:luptf?XWOPbi2TquAJ rztDzmxuU-vCzynWeZnpBdzc—y5bFXQtB91?ldm Pm7VAIPg4zm Wui
1 4-0 7-0-0 13-4-0 15-8-0
1 4-0 7-M 6-4-0 24-0
3x4 =
7-0-0
4x8 =
3 14
Scale = 1:28.3
3x6 11 6x8 =
15 16 17
II—II —
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.56
Vert(LL)
0.22
8-11
>744
240
TCDL 7.0
Lumber DOL
1.25
BC 0.39
Vert(CT)
-0.12
8-11
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.63
Horz(CT)
-0.01
7
n/a
n/a
BCDL 10.0
Code FBC2020rTP12014
Matrix -MS
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 2=506/0-8-0, 7=1375/0-8-0
Max Horz 2=281(LC 12)
Max Uplift 2=-631(LC 12), 7=-1702(LC 9)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-12=-507/671, 12-13=-453/676, 3-13=-433/692, 3-14=-345/218, 14-15=-345/218,
15-16=-345/218, 4-16=-345/218, 4-17=-345/218, 5-17=-345/218
BOT CHORD 2-8=-762/386, 7-8=781/394
WEBS 3-8=-470/298, 3-7=660/1292, 4-7=-661/1078, 5-7=-433/684
6x8 =
1 -B
15-8-0
4-
2-0-0
PLATES
GRIP
MT20
244/190
Weight: 80 lb
FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
Rigid ceiling directly applied or 7-4-1 oc bracing.
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 7-0-0, Exterior(2R) 7-0-0
to 11-2-15, Interior(1) 11-2-15 to 15-6-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 631 lb uplift at joint 2 and 1702 lb uplift at
joint 7.
7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-4=-54, 4-5=-354(F=-300), 6-9=-20
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa, FL 33910 .
Date:
February 10,2021
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall p�iTek••
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the iVl
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TP11 Quality Criteria, DSB-89 and SCSI Building.Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789559
77283
D7
HALF HIP
1
1
Job Reference (optional)
Chambers TnM, Inc., Fort Merce, FL rcun: oALo s aep 14 cote rnnr. o.rau s 1—YOU CVN nn,— umumuoa, H.I. — rw ,,+.+.,. i
ID:Iuptf7XWOPbi2TquAJrztDzmxuU-vCzynWeZnpBdzcy5bFXQtBBQ71fmST7VAIPg4zm Wui
1 4-0 6-3-9 9-0-0 13-4-0 15-M
1 4-0 6-3-9 2-8-7 4-4-0 213-0
Scale = 1:31.1
4x8 = 3X6 II 6x8 =
4x4 = 3X4 = 3x4
9-0-0
13-4-0 13 8,0 15- _o
9-0-0
4-4-0 -4- 2 1
Plate Offsets (X Y)-- [2:0-1-0 Edge] [4:0-5-4 0-2-0]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.43
Vert(LL) 0.34
9-12 >469 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.39
Vert(CT) -0.26
9-12 >624 240
BCLL 0.0
Rep Stress Incr NO
WB 0.40
Horz(CT) -0.01
8 n/a n/a
BCDL 10.0
Code FBC2020/TP12014
Matrix -MS
Weight: 91 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30
end verticals.
WEBS 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 7-1-9 oc bracing.
REACTIONS. (lb/size) 2=506/0-8-0, 8=1375/0-8-0
Max Horz 2=343(LC 12)
Max Uplift 2=-612(LC 12), 8=-1690(LC 9)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-13=-498/605, 13-14=-460/608, 3-14=389/622, 3-4=-288/464, 4-15=-300/171,
5-15=-300/171, 5-16=-300/171, 6-16=300/171
BOT CHORD 2-9=-834/412, 8-9=460/215
WEBS 3-9=-305/587, 4-9=-902/433, 4-8=-550/1102, 5-8=-595/1043, 6-8=409/719
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 9-0-0, Exterior(2R) 9-0-0
to 13-4-0, Interior(1) 13-4-0 to 15-6-4 zone; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 612 lb uplift at joint 2 and 1690 lb uplift at
joint B.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=54, 4-5=54, 5-6=-354(F=-300), 7-10=-20
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tempa.FL 33610
Date:
February 10,2021
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/192020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not•
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall ■
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing Mirek`
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Tcuss Type
Qty
Ply
T22789560
77283
GRA
HIP GIRDER
1
1
Job Reference (optional)
ID:luptf?XWOPbi2TquAJrctDzmxuU-sa5lCCfpJRSLDv8KDOH?WIGT1pzCEDnPyUE Wkzzm Wug
r1-0-Q 5-0-0 10-3-5 15F-11 20-10-0 26-11 4 32-10-12 39-0-0 44-0-0 t15 4-Q
1 4-0 5 3-5 5-3-5 5-3-5 6-1 4 5-11-8 6-1 4 5-0-0 1 4-0
t Scale = 1:75.9
4x8 =
5x8 =
6.00 12 3x4 = 3x6 =
3 29 30 4 31 32 33 5 34?�p
3x4 II 3x10 = 3x6 = 3x5 = 5x8 =
36 7 37 38 8 939 40 41 10 42 43 11
22 44 45 21 46 47 20 19 48 49 50 18 51 52 17 53 16 54 1S 55 56 74
3x5 - 3x4 II 3x4 - 3x6 = 6x12 = 3x5 = 4x6 - 3x4 = 3x4 II 3x5 -
3x4 =
THIS TRUSS IS NOT SYMMETRIC.
PROPER ORIENTATION IS ESSENTIAL.
15-6-11 20-10-0 26-11-4 32-10-12 39-M 44-0-0
5-3-5 5-3-5 6-1-4 5-11-8 6-1-4 ' 5-0-0
LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Wet] L/d PLATES GRIP
TCLL 20.0 Plate Grip DOL 1.25 TC 0.68 Vert(LL) 0.32 14-15 >868 240 MT20 244/190
TCDL 7.0 Lumber DOL 1.25 BC 0.45 Vert(CT) -0.23 14-15 >999 240
BCLL 0.0 Rep Stress Incr NO WB 0.98 HOrx(CT) -0.11 12 n/a n/a
BCDL 10.0 Code FBC2020/TPI2014 Matrix -MS
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3 *Except* WEBS
8-18: 2x4 SP M 30
REACTIONS. (lb/size) 2=1040/0-8-0, 18=3318/0-8-0, 12=1197/0-8-0
Max Horz 2=-152(LC 23)
Max Uplift 2=-1178(LC 8), 18=3858(LC 8), 12=-1377(LC 8)
Max Grav 2=1043(LC 17), 18=3318(LC 1), 12=1199(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1796/1858, 3-29=-1680/1810, 29-30=-1680/1810, 4-30=-1680/1810, 4-31=-327/393,
31-32=-327/393, 32-33=-327/393, 33-34=-327/393, 34-35=-327/393, 5-35=-327/393,
5-6=-2522/2284, 6-36=-2522/2284, 7-36=-2522/2284, 7-37=-2522/2284, 37-38=-2522/2284,
8-38=-2522/2284, 8-9=-880/1164, 9-39=-880/1164, 39-40=-880/1164, 40-41=-880/1164,
10-41=-880/1164, 10-42=-2302/2849, 42-43=-2302/2849, 11-43=-2302/2849,
11-12=-2152/2537
BOT CHORD 2-22=-150511558, 22-44=-1528/1580, 44-45=-1528/1580, 21-45=-1528/1580,
21-46=-1627/1680, 46-47=-1627/1680, 20-47=1627/1680, 20-48=-1627/1680,
1948=-1627/1680; 19-49=-265/327, 49-50=-265/327, 18-50=-265/327, 18-51=-994/880,
51-52=-994/880,17-52=-994/880,17-53=-2644/2302,16-53=-2644/2302,
16-54=-2644/2302, 15-54=2644/2302, 15-55=2134/1900, 55-56=-2134/1900,
14-56=-2134/1900, 12-14=-2106/1878
WEBS 3-22=-407/382, 4-21=-1771298, 4-19=1509/1584, 5-19=-928/837, 5-18=-2881/3229,
7-18=-527/627, 8-18=-3413/3996, 8-17=-957/825, 10-17=1552/1833, 11-15=-599/496,
11-14=-497/413
Weight: 213 lb FT = 20%
Structural wood sheathing directly applied or 4-4-7 oc purlins.
Rigid ceiling directly applied or 4-5-4 oc bracing.
1 Row at midpt 5-18, 8-18, 10-17
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=44ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left exposed; Lumber DOL=1.60 plate grip DOL=1.60 '
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1178 lb uplift at joint 2, 3858 lb uplift at
joint 18 and 1377lb uplift at joint 12.
c?
d
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa, FL 33610
Date:
February 10,2021
Continae g --
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall �
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing "
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the {q �iTek'
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?Pli Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789560
77283
GRA
HIP GIRDER
1
1
Job Reference (optional)
Chambers Trvss, Inc., Fort?Pierce, FL ,
Kun: o.42v s S.p i4 2625 nun. 6.436 o - av auav ,--- v,vvo, ,- , .u. C. . .
ID:luptf?XWOPbi2TquAJrztDzmxuU-sa5iCCfpJRSLDv8KDOH? WIGT?pzCEDnPyUE Wkzzm Wug
NOTES-
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 143 lb down and 167 lb up at 5-0-0, 143 lb down and 156 lb up at
7-0-12, 143 lb down and 156 lb up at 9-0-12, 143 lb down and 156 lb up at 11-0-12, 143 lb down and 156 lb up at 13-0-12, 143 lb down and 156 lb up at 15-0-12, 123 lb
down and 165 lb up at 17-0-12, 123 lb down and 165 lb up at 19-0-12, 123 lb down and 165 lb up at 21-0-12, 123 lb down and 165 lb up at 22-11-4, 123 lb down and 165
lb up at 24-11-4, 123 lb down and 165 lb up at 26-11-4, 123 lb down and 165 lb up at 28-11-4, 123 lb down and 165 lb up at 30-11-4, 123 lb down and 165 lb up at
32-11-4, 123 lb down and 165 lb up at 34-11-4, and 123 lb down and 165 lb up at 36-11-4, and 123 lb down and 176 lb up at 39-0-0 on top chord, and 230 lb down and
230 lb up at 5-0-0, 92 lb down and 5 lb up at 7-0-12, 92 lb down and 5 lb up at 9-0-12, 92 lb down and 5 lb up at 11-0-12, 92 lb down and 5 lb up at 13-0-12, 92 lb down
and 5 lb up at 15-0-12, 45 lb down and 64 lb up at 17-0-12, 45 lb down and 64 lb up at 19-0-12, 45 lb down and 108 lb up at 22-11-4, 45 lb down and 108 lb up at 24-11-4
, 45 lb down and 108 lb up at 26-11-4, 45 lb down and 108 lb up at 28-11-4, 45 lb down and 108 lb up at 30-11-4, 45 lb down and 108 lb up at 32-11-4, 45 lb down and
108 lb up at 34-11-4, and 45 lb down and 108 lb up at 36-11-4, and 227 lb down and 458 lb up at 38-11-4 on bottom chord. The design/selection of such connection
device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pif)
Vert: 1-3=-54, 3-11=-54, 11-13=-54, 23-26=-20
Concentrated Loads (lb)
Vert: 3=-65(B) 6=-62(B) 11=-62(B) 22=-230(6) 7=-62(B) 8=-62(6) 17=-36(B) 10=62(B) 15=-36(B) 14=-227(B) 9=-62(B) 29=-65(B) 30=-65(B) 31=-65(B) 32=-65(B)
35=-65(B) 36=-62(B) 37=-62(B) 38=-62(B) 41=-62(B) 42=-62(B) 43=-62(B) 44=-39(B) 45=-39(B) 46=-39(B) 47=39(B) 48=-39(B) 49=-36(B) 50=-36(B) 51=-36(B)
52=-36(B) 53=-36(B) 54=36(6) 55=-36(B) 56=-36(6)
A WARNING - Veiiy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. !'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek"
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPli Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
ly
Ply
T22789561
77283
GRB
HIP GIRDER
1
1
Job Reference (optional)
ID:lupff?XWOPb2TquAJrztDzmxuU-Knf4PYgR4kaCg3jXmjoE2WpZjDKozIJZB8_3HPzm Wuf
1 4-0 3-9 4 7-0-0 13-1-16 19-2-1 25-4-0 28-6-12 32.4-0 33 8-0
1-4-0 3-9-4 3-2-12 6-1-15 6-0-3 6-1-15 3-2-12 3-9
• Scale = 1:57.0
7x10 MT18HS =
A nn 171-1- 4 24 25
3x10 II 7x8 WB = 6x8 =
5 626 2728 7
7x10 MT18HS =
29 30 8
" — 31 17 32 — 33 34 '- 35 14 36 - --
48 — 3x4 II 3x4 = 6x8 = 4x10 = 3x8 = 6x8 = 3x4 = 3x4 II 48 —
3-9-4 71-0 13-1-15 19-2-1 25-4-0
F-1-15 6-0-3 6-1-15
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/dell Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 1.00
Vert(LL)
0.61 15-16 >641 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.43
Vert(CT)
-0.59 15-16 >657 240
MT18HS
244/190
BCLL 0.0
Rep Stress Incr NO
WB 0.84
Horz(CT)
-0.12 10 n/a n/a
BCDL 10.0
Code FBC2020lrP12014
Matrix -MS
Weight: 209 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30'Except*
TOP CHORD Structural wood sheathing directly applied or 2-3-5 oc purlins.
4-6,6-8: 2x6 SP No.2
BOT CHORD Rigid ceiling directly applied or 4-6-12 oc bracing.
BOT CHORD 2x6 SP 240OF 2.0E
WEBS
1 Row at midpt 4-16, 8-15
WEBS 2x4 SP No.3
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 2=2534/0-8-0, 10=2507/0-8-0
Max Horz 2=-186(LC 23)
Max Uplift 2=-2205(LC 8), 10=-2159(LC 8)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-5131/4377, 3-4=-5052/4413, 4-24=-635915441, 24-25=-6361/5442, 5-25=-6364/5443,
5-26=-6360/5439, 6-26=-6360/5439, 6-27=-6360/5439, 27-28=-6360/5439,
7-28=-6360/5439, 7-29=-6363/5427, 29-30=-6359/5426, 8-30=-6358/5424, 8-9=-4988/4307,
9-10=-5073/4276
BOT CHORD 2-19=-377214562, 18-19=-3772/4562, 18-31=-3756/4541, 17-31=375614541,
17-32=-3756/4541, 16-32=-3756/4541, 16-33=-5146/6359, 33-34=-5146/6359,
15-34=-5146/6359, 15-35=-3652/4479, 14-35=-3652/4479, 14-36=-3652/4479,
13-36=-3652/4479, 12-13=3682/4511, 10-12=3682/4511
WEBS 3-18=-373/338, 4-18=-718/810, 4-16=-1614/2141, 5-16=746/817, 7-15=-777/836,
8-15=-1714/2198, 8-13=-528/747, 9-13=-373/337
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=32ft; eave=4ft; Cat.
This item has been
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
electronically signed and
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
sealed by Velez, Joaquin, PE
the use of this truss component.
using a Digital Signature.
4) Provide adequate drainage to prevent water ponding.
Printed Copies Of this
5) All plates are MT20 plates unless otherwise indicated.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
document are not considered
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
signed and sealed and the
will fit between the bottom chord and any other members.
Signature must be Verified
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 2205 lb uplift at joint 2 and 2159 lb uplift
on any electronic copies.
at joint 10.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33910
Date:
February 10,2021
o trttted
WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
pal*
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing indicated is to buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
prevent
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPl1 Quality Criteria, DSB-99 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
ty
P y
T22789561
77283
GRB
HIP GIRDER
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort f+fierce, FL
mun: O.4— s Sep l4 Loco YIII¢ 6.450 s N— uv Lacv .- , , — . a oe=
ID:luptf?XWOPbi2TquAJrzlDzmxuU-Knf4PYgR4kaCg3jXmjoE2WpZjD KoziJZB8_3HPzmWuf
NOTES-
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 176 lb down and 215 lb up at 7-0-0, 176 lb down and 205 lb up at
9-0-12. 176 lb down and 205 lb up at 11-0-12, 176 lb down and 205 lb up at 13-0-12, 176 lb down and 205 lb up at 15-0-12, 176 lb down and 205 lb up at 17-3-4, 176 lb
down and 205 lb up at 19-3-4, 176 lb down and 205 lb up at 21-3-4, and 176 lb down and 205 lb up at 23-3-4, and 251 lb down and 426 lb up at 25-4-0 on top chord, and
463 lb down and 634 lb up at 7-0-0, 86 lb down and 33 lb up at 9-0-12, 86 lb down and 33 lb up at 11-0-12, 86 lb down and 33 lb up at 13-0-12, 86 lb down and 33 lb up at
15-0-12. 86 lb down and 33 lb up at 17-3-4, 86 lb down and 33 lb up at 19-3-4, 86 lb down and 33 lb up at 21-3-4, and 86 lb down and 33 lb up at 23-3-4, and 363 lb down
and 439 lb up at 25-3-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=54, 4-8=54, 8-11=54, 2-10=-20
Concentrated Loads (lb)
Vert: 4=-110(F) 6=110(F) 8=162(F) 18=-463(F) 16=-65(F) 5=-11Off) 7=-110(F) 15=-65(F) 13=-363(F) 24=-110(F) 25=11 O(F) 27=-11O(F) 29=-110(F) 30=11 O(F)
31=-65(F) 32=-65(F) 33=65(F) 34=65(17) 35=-65(F) 36=-65(F)
,& WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. �e
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not sot
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek"
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP1f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
y
T22789562
77283
GRC
HIP GIRDER
1
4
3
Job Reference (optional)
Chambers TrOss, Inc., Fort fierce, FL Kun: 8.420 s Sep in LULU rnnr. 6.430 s N" 30 2020 „ — , ,uu 665, 1 9
ID:luptf7XWOPbi2TquAJrztDzmxuU-5J865HmSBCa3olK3EPx6NC8zzR_GrJtk1 OwUzxzm WuX
4-11-5 9-0-3 1%1-0 16-2-0 19-3-0 23-3-13 27-0-11 32 4-0
4-11-5 4-0-13 4-0-13 3-1-0 3-1-0 4-0-13 4-0-13 4-11 5
6x8 =
3x4 11 6x8 =
Scale = 1:56.5
7x10 MT18HS i 3x10 11 6x8 = 5x8 MT18HS = 7x8 = 7x8 = 6x8 = 3x10 I I 7x10 MT18HS
9-0-3
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
NO
BCDL
10.0
Code FBC20201TPI2014
LUMBER -
TOP CHORD 2x6 SP No.2
BOT CHORD 2x6 SP 240OF 2.0E
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 1=14350/0-8-0, 9=13955/0-8-0
Max Horz 1=283(LC 24)
Max Uplift 1=-9216(LC 8), 9=-8652(LC 8)
Max Grav 1=14350(LC 1), 9=14563(LC 2)
7x8 = 5x8 MT18HS =
23-3-13
-0
CSI.
DEFL. in (loc) I/defl Ud
PLATES GRIP
TC 0.86
Vert(LL) 0.4215-17 >907 240
MT20 2441190
BC 0.71
Vert(CT) -0.51 11-13 >752 240
MT18HS 244/190
WB 0.93
Horz(CT) 0.16 9 n/a n/a
Matrix -MS
Weight: 750 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-10-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-26062/16750, 2-3=-22755/14669, 3-4=-18593/12058, 4-5=-17292/11275,
5-6=-17292/11275,6-7=-18641/12028,7-8=-23153/14599,8-9=-27175/16627
BOT CHORD 1-27=-6768/10574, 1-28=-14902/23289, 18-28=-14902/23289, 18-29=-14902/23289,
17-29=-14902/23289, 17-30=-12937/20353, 16-30=-12937/20353, 16-31=-12937/20353,
15-31=-12937120353, 15-32=-10539/16738, 14-32=-10539/16738, 14-33=-10510/16795,
33-34=-10510116795,13-34=-10510/16795,12-13=-12873/20709,12-35=-12873/20709,
35-36=-12873/20709, 11-36=-12873/20709, 11-37=-14791/24315, 37-38=-14791/24315,
10-38=-14791/24315, 10-39=-14791/24315, 39-40=-14791124315, 9-40=-14791/24315
WEBS 2-18=-1883/3019, 2-17=-3394/2265, 3-17=-3471/5451, 3-15=-5429/3597, 4-15=-4408/6832,
4-14=-836/2050, 5-14=-235/301, 6-14=-905/1408, 6-13=4334/7316, 7-13=-5877/3546,
7-11=-3416/5989,8-11=-4164/2211,8-10=-1836/3684
NOTES-
1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x6 - 2 rows staggered at 0-8-0 oc.
Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-4-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to
ply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=32ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
5) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
6) Provide adequate drainage to prevent water ponding.
'7) All plates are MT20 plates unless otherwise indicated.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 9216 lb uplift at joint 1 and 8652 lb uplift
at ioint 9.
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68132
MiTek USA, Inc. FL.Cert 8634
6904 Parke East Blvd. Tempa,FL 33610
Date:
February 10,2021
ntin -ed 9 ��
WARNING -verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall � Ar
ot
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IyliTek"
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
I cuss Type
QtY
Ply
'
T22789562
77283
GRC
HIP GIRDER
1
3
Job Reference (optional)
cnamoers l russ, mc., ron r ierce, 1-1-
wn.o.»1.. �.p w<v<.,�,,,,.. .,.,.. ,,,.,...,, .,, ...y....
ID:luptf?XWOPbi2TquAJrztDzmxuU-ZWiUldn4yViwPSvFo6SLwPh7jrKVam6uF1 g25Nzm WuW
NOTES-
11) Use USP HUS26 (With 14-16d nails into Girder & 6-16d nails into Truss) or equivalent spaced at 2-0-0 oc max. starting at 0-9-4 from the left end to 30-9-4 to connect
truss(es) to back face of bottom chord.
12) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 4-21=54, 4-6=-54, 6-25=-54, 1-9=-20
Concentrated Loads (lb)
Vert: 18=-1607(B)17=-1607(B)27=-1611(B)28=1607(B)29=-1607(B)30=-1607(B)31=-1607(B)32=-1607(B)33=-1607(B)34=-1607(B)35=-1607(B)36=1607(B)
37=-1607(B) 38=1612(B) 39=-1726(B) 40=1726(B)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek°
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
ty
PIY
T22789563
77283
GRID
HALF HIP GIRDER
2
1
Job Reference o tional
I., 1nmA — — Id-d-5 11i1 Pann 7
Chambers Trdss, Inc., Fort Pierce. FL o..<w .cp ,. <�<� �,,,,.. ,.... -- -_-- ..... _.. :..___...__, ..._. ..__ . __ . _ .... _.__ ___ - _ -
ID:luptf?XWOPbi2TquXJrztDzmxuU-ZWiUIdn4yVWFP vFo6SLwFh66rd6agcuF1g25NzmWuW
-1-4-0 5-0-0 10-4-0 15-8-0
1-4-0 5-0-0 5A-0 6A-0
3x4 =
Scale = 1:28.5
4x8 = 3x4 11
4x4 =
3 12 13 14 15 4 16 17 18 5
5-0-0 10-4-0 15-8-0
c n n S.d_n 5A-0
LOADING (psf)
SPACING-
2-0-0
CSI.
TCLL
20.0
Plate Grip DOL
1.25
TC 0.49
TCDL
7.0
Lumber DOL
1.25
BC 0.35
BCLL
0.0
Rep Stress Incr
NO
WB 0.64
BCDL
10.0
Code FBC20201TP12014
Matrix -MS
DEFL. in (loc) I/dell L/d
Vert(LL) 0.15 7-8 >999 240
Vert(CT) -0.10 7-8 >999 240
Horz(CT) -0.05 6 n/a n/a
LUMBER-
BRACING -
TOP CHORD
2x4 SP M 30
TOP CHORD
BOT CHORD
2x4 SP M 30
WEBS
2x4 SP No.3
BOT CHORD
WEBS
REACTIONS.
(lb/size) 2=990/0-8-0, 6=1028/0-8-0
Max Horz 2=220(LC 21)
Max Uplift 2=-1276(LC 8), 6=1394(LC 5)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD
2-3=-1679/2082, 3-12=-1490/1998, 12-13=-1490/1998, 13-14=-149011998,
14-15=-1490/1998, 4-15=-1490/1998, 5-6=-214/267
BOT CHORD
2-8=-1923/1454, 8-19=-1952/1475, 19-20=-1952/1475, 7-20=-1952/1475, 7-21=-1998/1490,
21-22=-1998/1490, 22-23=-1998/1490, 6-23=-1998/1490
WEBS
3-8=-507/380, 4-7=-346/342, 4-6=-1606/2151
6x8 =
PLATES GRIP
MT20 244/190
Weight: 76 lb FT = 20%
Structural wood sheathing directly applied or 5-6-4 oc purlins, except
end verticals.
Rigid ceiling directly applied or 5-0-8 oc bracing.
1 Row at midpt 4-6
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1276 lb uplift at joint 2 and 1394 lb uplift
at joint 6.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 123 lb down and 174 lb up at
5-0-0, 123 lb down and 165 lb up at 7-0-12, 130 lb down and 165 lb up at 9-0-12, 130 lb down and 165 lb up at 11-0-12, and 130 lb
down and 165 lb up at 13-0-12, and 119 lb down and 162 lb up at 14-10-12 on top chord, and 227 lb down and 289 lb up at 5-0-0,
45 lb down and 64 lb up at 7-0-12, 45 lb down and 64 lb up at 9-0-12, 45 lb down and 64 lb up at 11-0-12, and 45 lb down and 64 lb
up at 13-0-12, and 53 lb down and 72 lb up at 14-10-12 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
'1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=54, 3-5=-54, 6-9=-20
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek'USA, Inc. FL Cert 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
ntirme
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design into the overall
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek°
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIMP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
QtY
Ply
T22789563
77283
GIRD
HALF HIP GIRDER
2
1
Job Reference (optional)
chambers Truss, Inc., Fon Fierce, rL
Kun: oAzu S aeP 14 xuzu rnm: o.nau 51 VY ou zu4u mi I CR IINYJOICJ, a W. Y u - r gv a
ID:luptf?XWOPbi2TquAJrztDzmxuU-ZWiU Idn4yViwPSvFo6SLwPhDOrQ8agcuF1 g25Nzm WuW
LOAD CASE(S) Standard
Concentrated Loads (Ib)
Vert: 3=-62(B) 8=-227(B) 13=62(B) 15=-62(B) 16=-62(B) 17=-62(B) 18=-72(B) 19=-36(B) 20=-36(B) 21=-36(B) 22=-36(B) 23=39(B)
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek•
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPl1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
I russ
Truss Type
City
Ply
T22789564
77283
GRE
Hip Girder
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
4.00 F12
Run: 8.420 s Sep 14 2020 Pnnt: 8.430 s Nov 30 2020 MITek Industries, Inc. Wed Feb 10 14:43:26 2021 Page 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-1 iFsWzojjpgnl bUSMgzaSdDS5FjrJPB1 UhPbdgzm WuV
7-" 12-0-0
3-0-0 4-&0
4x8 = 4x4 =
2 14 3
Scale = 1:19.8
4x4 = 3x5 =
7-"
LOADING (ps,
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
Udefl
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.24
Vert(LL)
-0.06
6-9
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.51
Vert(CT)
-0.11
6-9
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.17
Horz(CT)
0.03
4
n/a
n/a
BCDL 10.0
Code FBC2020/TP12014
Matrix -MS
Wind(LL)
0.08
6-9
>999
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 1=941/0-10-9, 4=874/0-10-9
Max Horz 1=-40(LC 6)
Max Uplift 1=-577(LC 8), 4=543(LC 8)
PLATES GRIP
MT20 244/190
Weight: 45 Ito FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-10-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-5-9 oc bracing.
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-13=-2047/1363, 2-13=-2033/1391, 2-14=-1938/1362, 3-14=-193811362, 3-15=-2002/1377,
4-15=-2020/1349
BOT CHORD 1-16=-1260/1927, 16-17=-1260/1927, 6-17=-1260/1927, 6-18=-1284/1968,
18-19=-1284/1968, 5-19=-1284/1968, 5-20=-1245/1898, 20-21=-1245/1898,
4-21=-1245/1898
WEBS 2-6=-258/451, 3-5=-252/449
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 577 lb uplift at joint 1 and 543 lb uplift at
joint 4.
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 123 lb down and 62 lb up at
1-6-8, 121 lb down and 76 lb up at 4-6-0. 40 lb down and 86 lb up at 6-0-0, and 121 lb down and 76 lb up at 7-6-0, and 123 lb down
and 62 lb up at 10-5-8 on top chord, and 158 lb down and 93 lb up at 1-6-4, 60 lb down and 41 lb up at 1-6-8, 158 lb down and 93 lb
up at 3-6-4, 122 lb down and 97 lb up at 4-4-7, 158 lb down and 93 lb up at 5-6-4, 20 lb down and 63 lb up at 6-0-0, 122 lb down
and 97 lb up at 7-6-0, 158 lb down and 93 lb up at 7-6-4, and 158 lb down and 93 lb up at 9-6-4, and 60 lb down and 41 lb up at
10-5-8 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=54, 2-3=54, 3-4=54, 7-10=-20
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MITek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa.FL 33610
Date:
February 10,2021
ontinue o
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall Not
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MITek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI(rolf Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
I ruse
Tcuss Type
Qty
Ply
T22789564
77283
GRE
Hip Girder
1
1
Job Reference (optional)
chambers I rLLSS, Inc., i-on 1-ierce, FL
Y11 ID:luptf?XWOPbi2TquAJrztDzmxuU-1 iFsWzojjpgnl bUSMgzaSdDS5FjrJPBI UhPbdgzmWuV
LOAD CASE(S) Standard
Concentrated Loads (lb)
Vert: 6=-60(F) 5=-218(F=-60, B=-158) 14=6(F) 16=158(B) 17=-158(B) 18=-158(B) 19=10(F) 20=-158(B)
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall �1•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing ivi iTek•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789565
77283
HV8
Valley
1
1
Job Reference (optional)
Chambers Tmss, Inc., Fort Pierce, FL Run: 8.420 s Sep 14 2020 Pnnt: 8.430 s Nov 30 202o Mi I eK Inausines, mc. wea Yeo lu 14:43:ZI ZUZ1 rage 1
ID:Iuptf7XWOPbi2TquAJ rzlDzmxuU-VupFjJoLU7yefl3ewXVp7gmbRe6Y2u7AjL989Gzm WuU
1-9-0 3-5 4 4-6-12 6-3-0 8-0-0
1-9-0 1-8 4 1-1 8 1-8-4 1-9-0
4.00 12 4x4 =
3x4 i
4x4 =
2x3 11 2x3 11
3x4
Scale = 1:14.9
3-5-4 4-6-12 B-0.0
3-5-4 1-1-8 3-54
Plate Offsets (X Y)-- 12:0-3-0 Edgel [5:0-3-0 EdgeI
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/deft Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.33
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.16
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.06
Horz(CT) -0.00 6 n/a n/a
BCDL 10.0
Code FBC2020rrP12014
Matrix-S
Weight: 26 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied
or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. All bearings 8-0-0.
(lb) - Max Horz 1=39(LC 11)
Max Uplift All uplift 100 lb or less at joint(s) 8, 7 except 1=108(LC 12), 6=-108(LC 12)
Max Grav All reactions 250 lb or less at joints) 1, 6, 8, 7
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 1-2=-174/367, 2-3=-1641366, 3-4=-168/393, 4-5=-164/372, 5-6=1741371
BOT CHORD 1-8=-263/122, 6-7=-253/122
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MVVFRS (directional) and C-C Exterior(2E) 0-7-7 to 1-9-0, Interior(1) 1-9-0 to 3-5-4, Exterior(2E) 3-5-4 to
6-3-0, Interior(1) 6-3-0 to 7-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
5) Gable requires continuous bottom chord bearing.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This item has been
will fit between the bottom chord and any other members.
electronically Signed and
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 8, 7 except Qt=lb)
sealed by Velez, Joaquin, PE
1=108, 6=108.
using a Digital Signature.
LOAD CASE(S) Standard
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MITek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119=20 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based onlyupon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design Into the overall•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
M iTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1, Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789566
77283
HVA
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL Kun: 8AZU s pep 14 zUZU rnnl: e.4su s NOV aU zuzU M1 i ex mousmes, mu. Weu Fcb io w:vo:cr c„c - ye ,
ID:Iuptf7XWOPbi2TquAJrztDzmxuU-VupFjJoLU7yefl3ewXVp?gmere972tEAjL989Gzm WuU
13.2-8 14-9-8 28-0-0
13-2-8 1-7-0 13-2-8
Scale=1:46.5
4x4 =
4x4 =
3x4 15 14 13 12 11 10 9 3x4
3x6 =
13-2-8 1-7-0 13-2-8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/defl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.12
Vert(CT) n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(CT) 0.00 8 n/a n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix-S
Weight: 124 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. All bearings 28-0-0.
(lb) - Max Horz 1=272(LC 11)
Max Uplift All uplift 100 lb or less atjoint(s) 1, 8, 13, 11 except 9=-354(LC 12), 10=-205(LC 12), 15=-354(LC
12), 14=205(LC 12)
Max Grav All reactions 250 lb or less at joint(s) 1, 8, 11 except 9=561(LC 18), 10=351(LC 18), 15=561(LC 17).
14=351(LC 17), 13=257(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
TOP CHORD 3-4=-144/287, 4-5=140/298, 5-6=-144/283
WEBS 7-9=-357/405, 6-10=-215/286, 2-15=-356/405, 3-14=-215/286
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=28ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 13-2-8, Exterior(2E) 13-2-8
to 14-9-8, Exterior(2R) 14-9-8 to 19-0-7, Interior(1) 19-0-7 to 27-4-9 zone;C-C for members and forces & MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Provide adequate drainage to prevent water ponding.
This Item has been
5) All plates are 2x3 MT20 unless otherwise indicated.
electronically Signed and
6) Gable requires continuous bottom chord bearing.
Sealed by Velez, Joaquin, PE
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
using a Digital Signature.
8) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed Copies of this
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
;) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uplift atjoint(s) 1, 8, 13, 11 except
document are not considered
(jt=lb) 9=354, 10=205, 15=354,14=205.
signed and sealed and the
signature must be verified
LOAD CASE(S) Standard --
on any electronic copies.
Joaquin Velez PE No.68182
M1Tek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tompa.FL 33610
Date:
February 10,2021
® WARNING - Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek�
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
ty
Ply
T22789567
77283
J1
JACK -OPEN '
12
1
Job Reference (optional)
Chambers Trdss, Inc., Fort Pierce, FL Kun: o.azu s sep 14 zuzu Prim: 8.430 s Nov 50 2020 mu uk hid—iii s, i— .4 rayc
I D:luptf?XWO Pbi2TquAJ rztDzmxu U-z4 NdxfpzFQ4V GvdgTF02X21 ka2VpnLMKx?uiiizm WuT
-1-4-0 1-0-0
r 1-4-0 1-0-0
Scale = 1:7.8
Plate Offsets (X Y)—
[2:G-0-8 Edge)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc)
I/deft
Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.50
Vert(LL)
0.00
7
>999
360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.09
Vert(CT)
0.00
7
>999
240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00
4
n/a
n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix -MP
Wind(LL)
-0.00
7
>999
240
Weight: 6 lb FT = 20%u
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD
BOT CHORD 2x4 SP No.3 BOT CHORD
REACTIONS. (lb/size) 3=-2/Mechanical, 2=166/0-8-0, 4=-14/Mechanical
Max Horz 2=96(LC 12)
Max Uplift 3=-2(LC 1), 2=-239(LC 12), 4=-14(LC 1)
Max Grav 3=23(LC 12), 2=166(LC 1), 4=50(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Structural wood sheathing directly applied or 1-0-0 oc puriins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone; porch left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except (jt=lb)
2=239.
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd, Tampa, FL 33610
Date:
February 10,2021
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based onlyupon parameters shown, and is for an individual building component, not
Sal
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual tmss web and/or chord members only. Additional temporary and permanent bracing
M iTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP1l Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789568
77283
J3
JACK -OPEN
13
1
Job Reference (optional)
Chambers TrOss, Inc., Fort Pierce, FL
Run: 8.42U s sep 14 zuzu i nnt: t1.43U s NOV JU 2uzu mt I eK Inaus ies, inc. wed Feb lu 14:45;26 zuc i rage i
ID: I uptf?XWO Pbi2TquAJ rztDzmxu U-z4NdxfpzFQ4V GvdgTF02X21ka2TinLM Kx?ui iizm WuT
-1-4-0 3-0-0
1-4-0 3-0-0
I6
T
0
Scale = 1:12.8
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.50
Vert(LL) 0.01
4-7 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.23
Vert(CT) -0.01
4-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2020rTP12014
Matrix -MP
Weight: 12 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=60/Mechanical, 2=202/0-8-0, 4=30/Mechanical
Max Horz 2=156(LC 12)
Max Uplift 3=-74(LC 12), 2=-265(LC 12), 4=-55(LC 9)
Max Grav 3=63(LC 17), 2=202(LC 1), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 2-11-4 zone; porch left
and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb)
2=265.
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6.904 Parke East Blvd. Tampa, FL 33610
Date:
February 10,2021
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANShTFI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789569
77283
J5
JACK -OPEN
28
1
Job Reference (optional)
Chambers Tress, Inc., Fort Fierce, FL
Run: 8.420 s Sep 14 2020 Print: 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 14:43:28 2021 Page 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-z4NdxfpzFQ4VGvdgTF02X21mf2KSnLMKx?uiiizm WuT
1 4-0 5-0-0
1-410 5-0-0
Scale = 1:17.7
Plate Offsets (X Y)-- 12:0-0-4 Edgel
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) I/dell Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.36
Vert(LL) 0.11 4-7 >517 240
MT20 244/190
TCDL 7.0
Lumber COL 1.25
BC 0.82
Vert(CT) -0.05 4-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00 3 n/a n/a
BCDL 10.0
Code FBC2020rrP12014
Matrix -MP
Weight: 18 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
J
REACTIONS. (lb/size) 3=116/Mechanical, 2=269/0-8-0, 4=56/Mechanical
Max Horz 2=217(LC 12)
Max Uplift 3=-149(LC 12), 2=-326(LC 12), 4=-94(LC 12)
Max Grav 3=121(LC 17), 2=269(LC 1), 4=85(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 4-11-4 zone; porch left
and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
This Item has been
5) Refer to girder(s) for truss to truss connections.
electronically Signed and
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
sealed by Velez, Joaquin, PE
3=149, 2=326.
using a Digital Signature.
LOAD CASE(S) Standard
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.681k
MiTek USA, Inc.,FL Cert 6834
6904 Parke East Blvd. Tampa,FL 33610
Date:
February 10,2021
WARNING - verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS/rrPlf Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
o
russ
Truss Type
Qty
Ply
722789570
77283
J7
Jack -Open
10
1
Job Reference (optional)
Chambers Truss, Inc., FortPierce, FL
1-4-0
I
3x5 =
Run: 8.420 s Sep 14 2020 Print: 8.430 S NOV 30 2020 MiTeK Industries, Inc. Wed Feb 10 14:43:29 Z021 Page 1
ID:luptt?XWOPbi2TquAJrzlDzmxuU-SHx?8_gbOkCMu3CO1 yXH4FrrZSliWncTAfeFE9zm WuS
7-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.74
Vert(LL)
-0.08
4-7
>999
360
TCDL 7.0
Lumber DOL
1.25
BC 0.50
Vert(CT)
-0.18
4-7
>468
240
BCLL 0.0
Rep Stress Incr
YES
WB 0.00 —
- Horz(CT)
-0.01
3
file
n/a
BCDL 10.0
Code FBC2020rrP12014
Matrix -MP
Wind(LL)
0.21
4-7
>402
240
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
REACTIONS. (lb/size) 3=164/Mechanical, 2=340/0-8-0, 4=85/Mechanical
Max Horz 2=278(LC 12)
Max Uplift 3=-190(LC 12), 2=243(LC 12), 4=-13(LC 12)
Max Grav 3=190(LC 17), 2=340(LC 1), 4=126(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:23.5
PLATES GRIP
MT20 244/190
Weight: 24 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 6-11-4 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)
3=190,2=243.
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MITek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa,FL 33610
Date:
February 10,2021
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 6/19/2020 BEFORE USE.
Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall q�
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 VYiTek�
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSITTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
TrussType
Qty
Ply
T22789571
77283
JA
Jack -Open
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL stun: 8.420 s Sep i4 zuzu Print: 8.430 s Nov au 2020 Mi T en industiles, Inc. ,,ed rev 10 W"J:emu U aga
I D:luplf?XWOPbi2TquAJrztDzmxuU-SHx?8_gbOkCMu3CO1 yXH4FrvKSrYWncTAfeFE9zm WuS
-1-4-0 2-0-7
1-4-0 2-0-7
Scale = 1:10.4
2-0-7
2-0-7
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udell Ltd
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.50
Vert(LL) -0.00
7 >999 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.12
Vert(CT) -0.00
7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
3 n/a n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix -MP
Wind(LL) -0.00
7 >999 240
Weight: 9 Ib FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 2-0-7 oc puffins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=33/Mechanical, 2=175/0-8-0, 4=14/Mechanical
Max Horz 2=126(LC 12)
Max Uplift 3=-28(LC 9), 2=-202(LC 12)
Max Grav 3=40(LC 17), 2=175(LC 1), 4=31(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E)-1-4-13 to 1-7-3, Interior(1) 1-7-3 to 1-11-11 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except Qt=lb)
2=202.
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. Fl-cert 6634
6904 Parke East Blvd. Tampa FL.33610
Date:
February 10,2021
A WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verity the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Satetyinformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
I cuss Type
Qty
P y
T22789572
77283
JA5
Jack -Open
6
1
Job Reference (optional)
Chambers Tnrss, Inc., Fort Pierce, FL Kun: a.42U s Sep 14 ZUZU vnm: 6.44U s NOV au ZUZU MI I CK rn—Ines, Inc. vveu Feu ru w:vo.ov cvci Faye
ID:luptf?XWOPbi2TquAJrztDzmxuU-wTVNLKrDn2KDWDnDbg2WdTO6us?BFEsdPJNombzm WuR
4-1 0-8
4-10-8
ADEQUATE
SUPPORT
3,4 = REQUIRED
4-10-8
Scale = 1:17.0
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.38
Vert(LL) -0.02
3-6 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.87
Vert(CT) -0.05
3-6 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.01
2 n/a n/a
BCDL 10.0
Code FBC2020rrP12014
Matrix -MP
Wind(LL) 0.08
3-6 >757 240
Weight: 16 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 4-10-8 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 8-1-8 oc bracing.
REACTIONS. (lb/size) 1=178/Mechanical, 2=119/Mechanical, 3=59/Mechanical
Max Horz 1=148(LC 12)
Max Uplift 1=-73(LC 12), 2=140(LC 12), 3=-13(LC 12)
Max Grav 1=181(LC 17), 2=138(LC 17), 3=85(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vuit=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
ll; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 4-9-12 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=lb)
2=140.
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall'
building design. Bracing Indicated is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek"
prevent
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789573
77283
JB
Jack -Open
2
1
Job Reference (optional)
Chambers Trv*ss, Inc., Fort Pierce, FL
1-5-0
Run: 8.420 s Sep 14 2020 Print: 8.430 s Nov W ZU20 MITeK Industries, Inc. wed "D I 14:43:3U ZUZI vage I
ID:Iuptf7XWOPbi2TquAJrztDzmxuU-wTVNLKrDn2KDWDnDbg2WdTOI Ds92FEsdPJNombzm WuR
3-0-5
Scale = 1:12.4
3-0-5
3-05
Plate Offsets (X Y)-- [2:0-0-10 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.68
Vert(LL)
-0.00
4-7 >999 360
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.24
Vert(CT)
-0.01
4-7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT)
0.00
3 n/a n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix -MP
Wind(LL)
-0.01
4-7 >999 240
Weight: 12 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-0-5 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=60/Mechanical, 2=20910-8-0, 4=30/Mechanical
Max Horz 2=151(LC 12)
Max Uplift 3=-60(LC 12), 2=-213(LC 12), 4=-1(LC 9)
Max Grav 3=70(LC 17), 2=209(LC 1), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 3, 4 except at=lb)
2=213.
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MITek USA,.Inc. FL Cart 6634
6904 Parke East Blvd. Tampa.FL 33610
Date:
February 10,2021
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing T
ek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the Mi C
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
I russ
cuss ype
Qty
Ply
T22789574
77283
JC
Jack -Open
2
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL Run: 8.420 s Sep 14 2020 Print: 8.430 s Nov 30 2020 MiTeK Industries, Inc. Wed Feb 10 14:43:30 2021 Page 1
ID:lupff?XWOPbi2TquAJrztDzmxuU-wTVNLKrDn2KDWDnDbg2WdTO1 DsAfFEsdPJNombzmWuR
-1-5-0 1-0-5
1-5-0 1-0-5
Scale = 1:7.7
rn
Y
0
9
N
O
1-0-5
r
1-0-5
Plate Offsets (X Y)— [2:0-4-2 0-0-31
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.68
Vert(LL) 0.00
7 >999 360
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.13
Vert(CT) 0.00
7 >999 240
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2020rrP12014
Matrix -MP
Wind(LL) -0.00
7 >999 240
Weight: 6 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-0-5 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (lb/size) 3=-4/Mechanical, 2=175/0-8-0, 4=-16/Mechanical
Max Horz 2=95(LC 12)
Max Uplift 3=-4(LC 1), 2=-253(LC 12), 4=-16(LC 1)
Max Grav 3=26(LC 12), 2=175(LC 1), 4=53(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Comer(3) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ito uplift at joint(s) 3, 4 except (jt=lb)
2=253.
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
® WARNING -Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
my
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPN Quality Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Sufe 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss -Type
Qty
Ply
T22789575
77283
KJ3
Diagonal Hip Girder
2
1
Job Reference (optional)
Chambers Tress, Inc., Fort Pierce, FL
Kun: u.4zu s Sep 14 zuzu Ynn1: 0.4.6 5 im—JV 2626 Wi,-k umu id--, mc. cu i a i AuApV. ,
ID:lupff?XWOPbi2TquAJrztDzmxuU-Of3lZgrrXLT47NMP9NZ19gwLhGY9_h6mez7Ml1 zmWuQ
-1-5-14 3-3-14
1-5-14 3-3-14
m
v
0
Co
4
Scale = 1:12.6
LOADING (pso
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.12
Vert(LL)
-0.00
4-7
>999
360
MT20 2441190
TCDL 7.0
Lumber DOL
1.25
BC 0.05
Vert(CT)
-0.01
4-7
>999
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.00
Horz(CT)
0.00
2
n/a
n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix -MP
Wind(LL)
-0.00
4-7
>999
240
Weight: 13 lb FT = 20%
LUMBER -
TOP CHORD 2x4 SP M 30
BOT CHORD 2x4 SP M 30
REACTIONS. (lb/size) 3=67/Mechanical, 2=22410-8-9, 4=33/Mechanical
Max Horz 2=155(LC 8)
Max Uplift 3=-67(LC 8), 2=-225(LC 8), 4=-1(LC 5)
Max Grav 3=77(LC 25), 2=224(LC 1), 4=56(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
BRACING -
TOP CHORD Structural wood sheathing directly applied or 3-3-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except Qt=lb)
2=225.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 111 lb down and 60 lb up at
2-5-0 on top chord, and 25 lb down and 1 lb up at 2-5-0 on bottom chord. The design/selection of such connection device(s) is the
responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 4-5=-20
Concentrated Loads (lb)
Vert:9=1(B)
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 8834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek'
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1rPI1 Qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
T22789576
77283
KJ5
DIAGONAL HIP GIRDER
4
1
Job Reference (optional)
Chambers Tnbs, Inc., Fort Pierce, FL Kun: o.vzu s aep 19 zuzu rnm: a.nou s rvuv ou 4u2u im i en muww, mom. _u Gov 1u ,Y_.o , 4u4l .y_
ID:luptf?XWOPbi2TquAJrztDzmxuU-Of3lZgrrXLT47NMP9NZ19gwHmGUI_h6mez7M 11 zm WuQ
-1-10-10 3-8-10 7-0-2
-10 1-10- 3-6-10 3-3-8
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/defl
Ud
TCLL 20.0
Plate Grip DOL
1.25
TC 0.37
Vert(LL)
0.24
4-7
>348
240
TCDL 7.0
Lumber DOL
1.25
BC 0.30
Vert(CT)
-0.18
4-7
>473
240
BCLL 0.0
Rep Stress Incr
NO
WB 0.00
Horz(CT)
-0.01
3
n/a
n/a
BCDL 10.0
Code FBC2020/TPl2014
Matrix -MP
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
REACTIONS. (lb/size) 3=161/Mechanical, 2=379/0-10-15, 4=87/Mechanical
Max Horz 2=215(LC 8)
Max Uplift 3=-170(LC 8), 2=381(LC 8), 4=-134(LC 5)
Max Grav 3=161(LC 1), 2=379(LC 1), 4=125(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:17.3
PLATES GRIP
MT20 244/190
Weight: 25 lb FT = 20%
Structural wood sheathing directly applied or 6-0-0 oc purlins.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
3=170,2=381,4=134.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 120 lb down and 60 lb up at
1-6-1, 120 lb down and 60 lb up at 1-6-1, and 41 lb down and 95 lb up at 4-4-0, and 41 lb down and 95 lb up at 4-4-0 on top chord,
and 119 lb down and 37 lb up at 1-6-1, 119 lb down and 37 lb up at 1-6-1, and 17 lb down and 4 lb up at 4-4-0, and 17 lb down and
4 lb up at 4-4-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (pif)
Vert: 1-3=-54, 4-5=-20
Concentrated Loads (lb)
Vert: 11=-9(F=-5, B=-5)
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 6634
6604 Parke East Blvd. Tampa,FL 33610
Date:
February 10,2021
A WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTekO connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p pr
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the iVl
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1rP/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss ype
ty
Ply
T22789577
77283
KJ7
Diagonal Hip Girder
2
1
Job Reference (optional)
cnameers I nras, Inc., hon tierce, t-L muu. -4 P I » .
ID:luptf?XWOPbi2TquAJrztDzmxuU-ssd7mOsTlfbwlXxbi44_iuTTMfp2j3wwsdsvrUzm WuP
1-10-10 5-1-9 9-10-1
1-10-10 5-1-9 4-8-7
Scale = 1:22.1
Vim» 3x4 =
5-1-9
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) I/defl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.32
Vert(LL) 0.10
6-7 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL
1.25
BC 0.27
Vert(CT) -0.06
6-7 >999 240
BCLL 0.0
Rep Stress Incr
NO
WB 0.35
Horz(CT) -0.01
5 n/a n/a
BCDL 10.0
Code FBC2020rrP12014
Matrix -MS
Weight: 42 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 7-7-12 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (lb/size) 4=128/Mechanical, 2=518/0-10-15, 5=326/Mechanical
Max Horz 2=276(LC 8)
Max Uplift 4=-174(LC 8), 2=435(LC 8), 5=-378(LC 5)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-11=-751/721, 11-12=-686/745, 3-12=679/732
BOT CHORD 2-14=-807/679, 14-15=-807/679, 7-15=807/679, 7-16=807/679, 6-16=-807/679
WEBS 3-7=-245/281, 3-6=737/876
NOTES-
1) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
3) This truss has been designed for a 10.0 psf bottom chord jive load nonconcurrent with any other live loads.
4) ' This truss has been designed for a jive load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
4=174, 2=435, 5=378.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 120 lb down and 60 lb up at
1-6-1, 120 lb down and 60 lb up at 1-6-1. 41 lb down and 95 lb up at 4-4-0, 41 lb down and 95 lb up at 44-0, and 145 lb down and
179 lb up at 7-1-15, and 145 lb down and 179 lb up at 7-1-15 on top chord, and 56 lb down and 40 lb up at 1-6-1, 56 lb down and 40
lb up at 1-6-1, 17 lb down and 63 lb up at 4-4-0. 17 lb down and 63 lb up at 4-4-0, and 36 lb down and 108 lb up at 7-1-15, and 36
lb down and 108 lb up at 7-1-15 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
-LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-4=-54, 5-8=20
Concentrated Loads (lb)
Vert: 13=-80(F=-40, B=40) 15=-9(F=-5, B=-5) 16=-55(F=-27, B=-27)
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 8834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1TPI1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Sufe 203 Waldorf, MD 20601
Tampa, FL 36610
Job
russ
cuss Type
ty
7Job
T22789578
77283
V4
Valley
2
Fy
Reference (optional)
Chambers Tnlas, Inc., Fort Aerce, FL Run: 8.420 s Sep 14 2020 Print: 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 14:43:33 2021 Page 1
ID:lupff?XWOPbi2TquAJrztDzmxuU-K2BW Mt63zjnNgWoGobDE5Og53B2Sbb35HcTNwzmWuO
2-M 4-60
2-M 2-M
3x4 i
LOADING (psf)
SPACING- 2-0-0
CSI.
TCLL 20.0
Plate Grip DOL 1.25
TC 0.19
TCDL 7.0
Lumber DOL 1.25
BC 0.15
BCLL 0.0
Rep Stress Incr YES
WB 0.00
BCDL 10.0
Code FBC2020/TPI2014
Matrix-P
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (lb/size) 1=102/4-0-0, 3=102/4-0-0
Max Horz 1=-29(LC 10)
Max Uplift 1=-65(LC 12), 3=65(1_13 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
3x6 =
2
3x4
Scale = 1:7.6
DEFL. in (loc) I/deft Lid PLATES GRIP
Vert(LL) n/a - n/a 999 MT20 244/190
Vert(CT) n/a - n/a 999
Horz(CT) -0.00 3 n/a n/a
Weight: 11 lb FT = 20%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3.
LOAD CASE(S) Standard
This item has been
electronically signed and
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 8834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
,till WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall my
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing "
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek*
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
ly
Ply
T22789579
77283
V8
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce. FL Run: 8.420 s Sep 14 2020 Print: 8A30 s Nov 30 2020 MITek Industnes, Inc. Wea I-eb 10 14:43:33 ZOZI page 1
ID:Iupff7XWOPbi2TquAJrztDzmxuU-K2BW Mt63zjnNgWoGobDE5OWj3AOSay35HcTNwzmWuO
4-0-0
3x4 i
2x3 11
4x4 =
3x4
Scale = 1:15.0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr YES
Code FBC2020/TPI2014
CSI.
TC 0.79
BC 0.19
WB 0.11
Matrix-P
DEFL. in (loc) Udefl Ud
Vert(LL) n/a n/a 999
Vert(CT) nla n/a 999
Horz(CT) 0.00 3 n/a n/a
PLATES GRIP
MT20 244/190
Weight: 25 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=125/8-0-0, 3=125/8-0-0, 4=250/8-0-0
Max Horz 1=-70(LC 10)
Max Uplift 1=-100(LC 12). 3=100(LC 12), 4=-117(LC 12)
Max Grav 1=125(LC 1), 3=131(LC 18), 4=250(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-4=-176/354
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 4-0-0, Exterior(2R) 4-0-0 to
7-0-0, Interior(1) 7-0-0 to 7-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=100, 3=100, 4=117.
This item has been
electronically signed and
LOAD CASE(S) Standard
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
-
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
"
Joaquin Velez PE No.68182
MITek USA, Inc. FL.Cort 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. '
Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Nil
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTek•
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPlf Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss Type
Qty
Ply
T22789580
77283
V12
Valley
1
1
a
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL Run: 8.420 s Sep 14 2020 Print: 8.430 s Nov 30 2020 MITeK Industries, Inc. wed I-eb 1u 14:46:33 tun rage 1
ID: luptf?XWOPbi2TquAJrztDzmxuU-K2BWMt63zjnNgWoGobDE50dg366SZR35HcTNwzmWuO
6-0-0 12-0-0
6-0-0 6-0-0
Scale = 1:20.7
4x6 =
3x4 4
2x3 11 3x4
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.34
Vert(LL) n/a
n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.47
Vert(CT) n/a
n/a 999
BCLL 0.0
Rep Stress Incr YES
WB 0.14
Horz(CT) 0.00
3 n/a n/a
BCDL 10.0
Code FBC2020/TP12014
Matrix-S
Weight: 39 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. (lb/size) 1=182/12-0-0, 3=182/12-0-0, 4=432/12-0-0
Max Horz 1=-112(LC 10)
Max Uplift 1=-138(LC 12), 3=-138(LC 12), 4=-230(LC 12)
Max Grav 1=184(LC 21), 3=195(LC 18), 4=432(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 2-4=-281/467
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 6-0-0, Exterior(2R) 6-0-0 to
9-0-0, Interior(1) 9-0-0 to 11-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)
1=138, 3=138, 4=230.
This Item has been
electronically signed and
LOAD CASE(S) Standard
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 8634
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/1912020 BEFORE USE. '
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall MOW
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTPH quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Jo
Truss ype
Qly
P yT22789581
71usssi
Valley
1
1
_:1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL Run: 8.420 s sap 14 zuzu Pnnt: 8.45u s Nov su 2020 ivi ex mausmes, Inc. vvea Feb 10 14:43:34 2021 ray. 1
I D:lupff?XWOPbi2TquAJrztDzmxuU-oEkuBiukgGre?g5_gV7SnJYmYTZIBOkCKxLOvMzm WuN
8-0-0 16-0-0
8-0-0 8-0-0
Scale = 1:26.6
4x4 =
3x4 i 8 7 b 3x4
2x3 11 2x3 11 2x3 11
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/deft Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.46
Vert(LL)
n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.06
Vert(CT)
n/a n/a 999
BCLL 0.0
Rep Stress Incr YES
WE 0.14
Horz(CT)
0.00 5 n/a n/a
BCDL 10.0
Code FBC20201rP12014
Matrix-S
Weight: 58 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 16-0-0.
(lb) - Max Horz 1=-154(LC 10)
Max Uplift All uplift 100 lb or less at joints) 1, 5, 7 except 6=-273(LC 12), 8=273(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 1, 5 except 7=251(LC 1),
6=362(LC 18), 8=362(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 4-6=-275/456, 2-8=-275/456
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 8-0-0, Exterior(2R) 8-0-0 to
11-0-0, Interior(1) 11-0-0 to 15-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except (jt=lb)
6=273, 8=273.
This item has been
electronically signed and
LOAD CASE(S) Standard
sealed by Velez, Joaquin, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cart 8634
69D4 Parke East Blvd. Tampa FL 33810
Date:
February 10,2021
WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall n
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing 1 V IiTek'
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?PH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T22789582
77283
V20
Valley
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL Run: 8.420 s Sep 14 2020 Print: 8.430 s Nov 30 2020 MiTek Industries, Inc. Wed Feb 10 14:43:34 2021 Page 1
ID:luptf?XWOPbi2TquAJrzlDzmxuU-oEkuBiukgGre?g5_gV7SnJYLTTfBORCKxLOvMzm WuN
10-0-0 20-0-0
10-0-0 10-0-0
Scale = 1:32.9
4x4 =
3x4 i 8 7 6 3x4
2x3 II 5x6 = 2x3 II
20-0-0
20-0-0
Plate Offsets (X,Y)— [7:0-3-0,0-3-0)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Vdefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.67
Vert(LL) n/a n/a 999
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.38
Vert(CT) n/a n/a 999
BCLL 0.0 '
Rep Stress Incr YES
WB 0.15
Horz(CT) 0.00 5 n/a n/a
BCDL 10.0
Code FBC2020/TPI2014
Matrix-S
Weight: 75 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 20-0-0.
(lb) - Max Horz 1=-195(LC 10)
Max Uplift All uplift 100 lb or less at joints) 1, 5 except 6=366(LC 12), 8=-366(LC 12)
Max Grav All reactions 250 lb or less atjoint(s) 1, 5, 7 except 6=486(LC 18), 8=486(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
WEBS 4-6=-360/518, 2-8=360/518
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; 6=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 10-0-0, Exterior(2R) 10-0-0
to 13-0-0, Interior(1) 13-0-0 to 19-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)
This item has been
6=366, 8=366.
electronically signed and
sealed by Velez, Joaquin, PE
LOAD CASE(S) Standard
using a Digital Signature.
Printed copies of this
document are not considered
`
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL.Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall�o
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
M itek°
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabdcation, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/1"Pl1 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
o
Truss
Truss Type
city77Jb
722789583
77283
V24
Valley
1
Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL Run: 8.420 s Sep 14 2020 Print: 8.430 s Nov 30 2020 MITek Industries, Inc. Wed Feb 10 14:43:35 2021 Page 1
ID:luptf?XWOPbi2TquAJrztDzmxuU-GRIGP2vMbazVc_gAODehKW5_ltmdwTXMYb5ZSozm WuM
12-0-0 24-0-0
12-0-0 12-0-0
45 =
Scale = 1:39.5
3x4 i 8 13 7 14 6 3x4
2x3 II 5x5 = 2x3 II
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/dell
Lid
TCLL 20.0
Plate Grip DOL 1.25
TC 0.27
Vert(LL)
n/a
n/a
999
TCDL 7.0
Lumber DOL 1.25
BC 0.59
Vert(CT)
n/a
n/a
999
BCLL 0.0
Rep Stress Incr YES
WB 0.16
Horz(CT)
0.00 5
n/a
n/a
BCDL 10.0
Code FBC2020/TP12014
Matrix-S
PLATES GRIP
MT20 244/190
Weight: 89 lb FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3
REACTIONS. All bearings 24-0-0.
(lb) - Max Horz 1=-237(LC 10)
Max Uplift All uplift 100 lb or less at joints) 1, 5, 7 except 6=-422(LC 12), 8=-422(LC 12)
Max Grav All reactions 250 lb or less at joints) 1, 5 except 7=536(LC 17), 6=669(LC 18), 8=669(LC 17)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown
TOP CHORD 2-10=-157/271, 3-10=-120/282, 3-11=120/273, 4-11=-141/262
WEBS 3-7=-255/152, 4-6=429/552, 2-8=-429/552
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-16; Vult=170mph (3-second gust) Vasd=132mph; TCDL=4.2psf; BCDL=3.Opsf; h=16ft; B=45ft; L=24ft; eave=4ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2E) 0-7-7 to 3-7-7, Interior(1) 3-7-7 to 12-0-0, Exterior(2R) 12-0-0
to 15-0-0, Interior(1) 15-0-0 to 23-4-9 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) Building Designer / Project engineer responsible for verifying applied roof live load shown covers rain loading requirements specific to
the use of this truss component.
4) Gable requires continuous bottom chord bearing.
5) This truss has been designed for a 10.0 psf bottom chord live load nonccncurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
This Item has been
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 1, 5, 7 except (jt=lb)
electronically signed and
6=422, 8=422.
sealed by Velez, Joaquin, PE
LOAD CASE(S) Standard
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Joaquin Velez PE No.68182
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
February 10,2021
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design is based only upon parametersshown, and is for an Individual building component, not
a tmss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall H V _
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing iViiTek�
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Symbols
PLATE LOCATION AND ORIENTATION
14-1 3/4' Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
0-11fi ,
-
-I-
For 4 x 2 orientation, locate
plates 0- 'lid' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
* Plate location details available in MITek 20/20
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
LATERAL BRACING LOCATION
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
Ft number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
aNSI/TPH: National Design Specification for Metal
Plate Connected Wood Truss Construction.
QSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
C1
of
O
U
a.
O
H
Numbering System
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
2 3
TOP CHORDS
8 7 6 5
0
Of
O
r
U
0-
0
F
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
]CC -ES Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTekO All Rights Reserved
Bill
MiTek
MITek Engineering Reference Sheet: MII-7473 rev. 5/19/2020
® General Safety (Votes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal orX-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/TPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSIrrPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19% at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects, equal to or better than that
specified.
13. Top chords must be sheathed or pur ins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSIrrPI 1 Quality Criteria.
21.The design does not take into account any dynamic
or other loads other than those avressly stated.