HomeMy WebLinkAboutAPPROVED, bergen_roofing_permit_info_sheet.pdfLLLLL
I." L Q ti L L
ST. LUCIE
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Low Slope Application
Required Sections of
the Permit Application
Form
A, B, C
Attachments Required
See List Below
1,2,3,4,5,5,7
2,4,5,6,7
Prescriptive BUR-RAS 150
A, B, C
Asphaltic Shingles
A, B, D
1,2,4,5,6,7
Concrete or Clay Tile
A, B, D. E
1,2,3,4,5,6,7
Metal Roofs
A, B, D
1,2,3,4,v,6,T
Wood Shingles and
Snakes
A, B, D
Other
As Applicable
1.2.3.4.5.6.7
ATTACHMENTS REQUIRED As Applicable):
1.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
Other Component of Product Approval
4.
S.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7,
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
S% LUCIE
Section A (General Information)
Master Permit No. Process No.
Contractors Name: License #
Job Address -7g true-� l Allu t . 1��L . lri-, --3 010r"SLP
ROOF CATEGORY
O Low Slope 0 Mechanically Fastened Tile Mortar/Adhesive Set Tiles
0 Asphaltic Shingles 0 Metal Panel/Shingles OWood Shingles/Shakes
0 Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
O New roof 0 Repair 0 Maintenance 0 Reroofing 0 Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) U OCO Total (SF) _
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
ST. LUCID
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: %,I '
Product Approval No.:`
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': Zone 1: Zone 2: Zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck:
Type:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bondin Material:
Base Sheet(s) & No. of
Base Sheet Fastener/B
Ply Sheet(s)' &
Ply Sheet Fasto
Top Ply:
Material:
of Ply(s):
/Bonding Material:
Top Ply Fastener/Bonding Material:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':_.._."
oc @ Lap, # Rows— ® "oo '
Zone 1:—"
oc @ Lap, # Rows ® "oo '
Zone 2:_.
_" oc @ Lap, # Ro " oc
Zone 3•
" oc @ Lap, # ws C�3 "oc
Number of Fasteners P Insulation Board:
Zone 1': Zone 2: Zone 3:
Illustrate Comp vents Noted and Details as Applicable:
Woodblocki 96Gutter, Edge Termination, Stripping,
Flashing, ontinuous Cleat, Cant Strip, Base Flashing,
Counte shing, Coping, Etc..
Indica :Mean Roof Height, Parapet Height, Height of Base
Flas ing, Component Material, Material' Thickness, Fastener
T e, Fastener Spacing orSubmit Manufacturers Details that
omply with RAS 111 and Chapter 16..
ST. LUCI E
Section D (Steep Slope Roof System)
Roof System Manufacturer:
Notice of Acceptance Number: v
kt.1-7--nFe - fZA
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: Zone 2e: Zone 2n:_Zone 2r: Zone 3e: Zone 3r:
Deck Type:
Type Ur
Roof Slope:
42 Ins
Ridge Verflatian?
fJ Le
Mean Roof Height: _ 12
Fire Barrier: N
Fastener Type & Spacing: g
\ Adhesive Type: 0
Type Cap Sheet
Roof Covering
Type & Size Drip
Edge:
ST. LUCIE
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mf. If the Mf values
are greater than or equal to the Mrvalues, for each area of the roof, then the the attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: x 1 = ---) - Mg: = Md Product Approval M-
(Zone 2e: . x ;L _ - Mg: = Mem Product Approval Mt
(Zone 2n: x )i. _ _) - Mg: = Mm, Product Approval Mf
(Zone 2r: x _ -J - Mg: = Mew Product Approval Mf
(Zone 3e: x _ --) - Mg: = M,3• Product Approval Mf
(Zone 3r: x)-_ ----J - Mg: _ Me Product Approval Mr
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance NJ From Table Belowl&-'tProduct AoDroval Mf 31 •',i
Mr required Moment
Resistance"
Mean Roof Height Roof Slope
15'
20'
2S'
30'
40'
2:12
34.4
36.5
38.2
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
25.9
27.1
28.2
30.0
'Must be used in conjunction with a list of moment based tile systems
• For Uplift based tile systems use Method 3. Compare the values for F' with the values for Fr If the F' values are greater than or
equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T
(Zone 1: x L =x W:= ) -W: cos r =Fri Product Approval F'
(Zone 2e: x L =x W:=) -W: cos r =Fr2e Product Approval F.
(Zone 2n: x L =x W:= ) -W: cos r =Fr2n Product Approval F'
(Zone 2r: x L =x W:= ) -W: cos r =Fr2r Product Approval F'
(Zone 3e: x L =x W:= ) -W: cos r =Fr3e Product Approval F
(Zone 3r: x L =x W:=_) -W: cos r =Fr3r Product Approval F'
Where to Obtain Information
Description
Symbol
Where to find
Design Pressure
Zones 1, 2e, 2n, 2r, 3e, 3r
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
0
Job Site
Aerodynamic Multiplier
a
Product Approval
Restoring Moment due to Gravity
M8
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
MB
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
Product Approval
All calculations must be submitted to the building official at the time of
permit application.