APPROVED CORRECTED ENGINEERING
DIRECTORY OF PAGES PV-1 PROJECT SUMMARY PV-2 SITE PLAN PV-3 SINGLE-LINE DIAGRAM PV-4 SAFETY LABELS PV-5.1 ATTACHMENT PLAN 5.1 PV-5.2 ATTACHMENT PLAN 5.2 PV-5.3 ATTACHMENT PLAN 5.3 PV-5.4 ATTACHMENT PLAN 5.4 PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN APPENDIXARRAY WIRING BOX DATASHEET INVERTER DATASHEET MOUNTING SYSTEM DATASHEET ANCHOR DATASHEET PROJECT DETAILS PROPERTY ADDRESS 8528 COBBLESTONE DR, FORT PIERCE, FL 34945 US ZONING RESIDENTIAL USE AND OCCUPANCY CLASSIFICATION ONE- OR TWO-FAMILY DWELLING GROUP (GROUP R3) UTILITY COMPANY FLORIDA POWER & LIGHT CO ELECTRICAL CODE 2017 NEC (NFPA 70) FIRE CODE 2018 NFPA 1 OTHER BUILDING CODES 2020 FL BUILDING CODE CONTRACTOR INFORMATION CONTRACTOR SIGNATURE SCOPE OF WORK THIS PROJECT INVOLVES THE INSTALLATION OF A GRID- INTERACTIVE PV SYSTEM. PV MODULES WILL BE MOUNTED USING A PREENGINEERED MOUNTING SYSTEM. THE MODULES WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED BY THE LOCAL UTILITY AND PERMITTING JURISDICTION. THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH APPLICABLE CODES AND REGULATIONS. THE DOCUMENT SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS LISTING AND INSTALLATION INSTRUCTIONS, AS WELL AS ALL APPLICABLE CODES. NOTHING IN THIS DOCUMENT SHALL BE INTERPRETED IN A WAY THAT OVERRIDES THEM. CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL CONDITIONS, DIMENSIONS, AND DETAILS IN THIS DOCUMENT. SYSTEM DETAILS DESCRIPTION NEW GRID-INTERACTIVE PV SYSTEM WITH NO ENERGY STORAGE DC RATING OF SYSTEM 10.64KW AC RATING OF SYSTEM 8.12KW AC OUTPUT CURRENT 33.9A INVERTER(S)28 X ENPHASE IQ7PLUS-72-2-US MODULE Q-CELLS Q.PEAK DUO BLK ML-G9+ 380 ARRAY WIRING (1) BRANCH OF 2 IQ7PLUS-72-2-US MICROINVERTERS (2) BRANCH OF 13 IQ7PLUS-72-2-US MICROINVERTERS INTERCONNECTION DETAILS POINT OF CONNECTION NEW LOAD-SIDE AC CONNECTION PER NEC 705.12(B)(2)(3)(B) AT MSP UTILITY SERVICE 120/240V 1Φ LOCATION MAIN SERVICE PANEL W/200A BUSBAR 175A MCB (DERATED) SITE DETAILS ASHRAE EXTREME LOW 0°C (32°F) ASHRAE 2% HIGH 33°C (91°F) CLIMATE DATA SOURCE VERO BEACH MUNICIPAL AIRPORT (KVRB) WIND SPEED 160 MPH (ASCE7-16) RISK CATEGORY II WIND EXPOSURE CATEGORY B P-161530 GRID-TIED SOLAR POWER SYSTEM8528 COBBLESTONE DRFORT PIERCE, FL 34945PROJECT SUMMARY DOC ID:161530-199148-1 DATE:7/1/21 CREATOR: REVIEWER: REVISIONS PV-1 GENERAL NOTES 1 EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT SATISFY MINIMUM WORKING CLEARANCES PER NEC 110.26. 2 CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. 3 CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT, CABLES, ADDITIONAL CONDUITS, RACEWAYS, AND OTHER ACCESSORIES NECESSARY FOR A COMPLETE AND OPERATIONAL PV SYSTEM. (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 6 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 323° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 9 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 54° AZIMUTH (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 3 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 233° AZIMUTH (N) TRANSITION BOX, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFMC CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) PROPOSED ROOF-MOUNTED PHOTOVOLTAIC ARRAY. 6:12 (27°) SLOPED ROOF, 10 PV MODULES (BLACK FRAME, BLACK BACKSHEET), 144° AZIMUTH (N) TRANSITION BOX, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN LFMC CONDUIT THROUGH THE INTERIOR OF THE BUILDING (N) AC COMBINER, OUTDOOR , OUTPUT CIRCUIT CONDUCTORS SHALL BE RUN IN PVC-40 CONDUIT OVER ROOF NO CLOSER THAN 0.5" ABOVE ROOF SURFACE (E) MAIN SERVICE PANEL (MSP), OUTDOOR (E) UTILITY METER, OUTDOOR (N) VISIBLE, LOCKABLE, READILY-ACCESSIBLE AC DISCONNECT LOCATED WITHIN 10 FT OF UTILITY METER, OUTDOOR ROADWAY ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-161530 GRID-TIED SOLAR POWER SYSTEM8528 COBBLESTONE DRFORT PIERCE, FL 34945SITE PLAN DOC ID:161530-199148-1 DATE:7/1/21 CREATOR: REVIEWER: REVISIONS PV-2 PV MODULE MICRO- INVERTER PM1-28 380W 13 IN BRANCH 13 IN BRANCH 2 IN BRANCH 1 2 3 4 5 6 7 JUNCTION BOXES 2 1 3 JB1-2 AC COMBINER CB2 20A CB1 20A 4 CB3 20A C1 8 PV DISCONNECT SW1 60A 5 LOADS MAIN SERVICE PANEL AC GEC KWHR LOAD LINE KWHR LOAD LINE UTILITY METER (E) 240/120V 1ɸ, 3W 200A BUSBAR (N) 175A MAIN BREAKER CB5 175A CB4 50A 9 10 11 12 MODULES REF.QTY.MAKE AND MODEL PMAX PTC ISC IMP VOC VMP TEMP. COEFF. OF VOC FUSE RATING PM1-28 28 Q-CELLS Q.PEAK DUO BLK ML-G9+ 380 380W 352W 10.50A 10.04A 45.0V 37.8V -0.122V/°C (-0.27%/°C)20A INVERTERS REF.QTY.MAKE AND MODEL AC VOLTAGE GROUND RATED POWER MAX OUTPUT CURRENT MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY I1-28 28 ENPHASE IQ7PLUS-72-2-US 240V NOT SOLIDLY GROUNDED 290W 1.2A 15.0A 60V 97.0% DISCONNECTS REF.QTY.MAKE AND MODEL RATED CURRENT MAX RATED VOLTAGE SW1 1 EATON DG222URB OR EQUIV.60A 240VAC OCPDS REF.QTY.RATED CURRENT MAX VOLTAGE CB1-2 2 20A 240VAC CB3 1 20A 240VAC CB4 1 50A 240VAC CB5 1 175A 240VAC SYSTEM SUMMARY BRANCH 1 BRANCH 2 BRANCH 3 INVERTERS PER BRANCH 13 13 2 MAX AC CURRENT 15.73A 15.73A 2.42A MAX AC OUTPUT 3,770W 3,770W 580W ARRAY STC POWER 10,640W ARRAY PTC POWER 9,856W MAX AC CURRENT 34A MAX AC POWER OUTPUT 8,120W DERATED AC POWER OUTPUT 8,120W NOTES THE DC AND AC CONNECTORS OF THE ENPHASE IQ7PLUS-72-2-US AND ARE LISTED TO MEET REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(D). MATING CONNECTORS SHALL COMPLY WITH NEC 690.33. 1 THE ENPHASE IQ7PLUS-72-2-US HAS A CLASS II DOUBLE-INSULATED RATING AND DOES NOT REQUIRE GROUNDING ELECTRODE CONDUCTORS (GEC) OR EQUIPMENT GROUNDING CONDUCTORS (EGC). THE RATING INCLUDES GROUND FAULT PROTECTION (GFP). TO SUPPORT GFP, USE ONLY PV MODULES EQUIPPED WITH DC CABLES LABELED PV WIRE OR PV CABLE. 2 ENPHASE SYSTEM MEETS REQUIREMENTS FOR PHOTOVOLTAIC RAPID SHUTDOWN SYSTEM (PVRSS), AS PER NEC 690.12(B).3 MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS. THEY ARE ROHS, OIL RESISTANT, AND UV RESISTANT. THEY CONTAIN TWO 12 AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL3003 AND UL 9703. 4 DC PV CONDUCTORS ARE NOT SOLIDLY-GROUNDED. NO DC PV CONDUCTOR SHALL BE WHITE- OR GRAY-COLORED5 ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(A) AND PART III OF ARTICLE 250 AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45. THE GROUNDING ELECTRODE SYSTEM SHALL ADHERE TO NEC 690.47(A) AND NEC 250.169. THE DC GROUNDING ELECTRODE SHALL BE SIZED ACCORDING TO NEC 250.166 AND INSTALLED IN COMPLIANCE WITH NEC 250.64. 6 MAX DC VOLTAGE OF PV MODULE IS 48.1V AT 0°C (0°C - 25°C) X -0.122V/C + 45.04V = 48.1V).7 AC AGGREGATION PANEL BUSBAR AND THE OVERCURRENT PROTECTION PROTECTING THE BUSBAR SHALL BE SIZED IN ACCORDANCE WITH NEC 705.12(B)(2)(3)(C)8 (E) 200A MAIN BREAKER DERATED TO (N) 175A9 POINT-OF-CONNECTION IS ON LOAD SIDE OF SERVICE DISCONNECT, IN COMPLIANCE WITH NEC 705.12(B)(2)(3)(B). OUTPUT IS BACKFED THROUGH BREAKER IN MAIN PANEL.10 THE BREAKER SHALL BE LOCATED AT THE OPPOSITE END OF THE BUSBAR FROM THE MAIN BREAKER. THE BREAKER SHALL NOT BE MARKED FOR "LINE" AND "LOAD".11 PV SYSTEM DISCONNECT SHALL BE A VISIBLE KNIFE-BLADE TYPE DISCONNECT THAT IS ACCESSIBLE AND LOCKABLE BY THE UTILITY. THE DISCONNECT SHALL BE LOCATED WITHIN 10 FT OF UTILITY METER. DISCONNECT SHALL BE GROUPED IN ACCORDANCE WITH NEC 230.72. 12 CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS ID TYPICAL CONDUCTOR CONDUIT / CABLE CURRENT-CARRYING CONDUCTORS IN CONDUIT / CABLE OCPD EGC TEMP. CORR. FACTOR FILL FACTOR CONT. CURRENT MAX. CURRENT (125%) BASE AMP.DERATED AMP. TERM. TEMP. RATING AMP. @ TERM. TEMP. RATING 1 1 10 AWG THWN-2, COPPER 0.5" DIA. LFMC 2 20A 10 AWG THWN-2, COPPER 0.76 (53°C)1.0 15.73A 19.66A 40A 30.4A 90°C 40A 2 1 10 AWG THWN-2, COPPER 0.75" DIA. LFMC 4 20A 10 AWG THWN-2, COPPER 0.76 (53°C)0.8 15.73A 19.66A 40A 24.32A 90°C 40A 3 1 10 AWG THWN-2, COPPER 0.75" DIA. LFMC 4 20A 10 AWG THWN-2, COPPER 0.76 (53°C)0.8 2.42A 3.02A 40A 24.32A 90°C 40A 4 1 8 AWG THWN-2, COPPER 0.75" DIA. PVC-40 3 50A 10 AWG THWN-2, COPPER 0.96 (33°C)1.0 33.88A 42.35A 55A 52.8A 75°C 50A 5 1 8 AWG THWN-2, COPPER 0.75" DIA. PVC-40 3 50A 10 AWG THWN-2, COPPER 0.96 (33°C)1.0 33.88A 42.35A 55A 52.8A 75°C 50A REVISIONS PROJECT ID: CREATED BY: CHECKED BY: DATE: SCALE:GRID-TIED SOLAR POWER SYSTEMFORT PIERCE, FL 349458528 COBBLESTONE DRPV-3 P-161530 07/01/21 SDT 161530 SINGLE-LINE DIAGRAM 1 PV-3 SINGLE-LINE DIAGRAM NTS GROUNDING NOTES 1 ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE REQUIREMENTS OF NEC ARTICLES 250 & 690 2 PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS USING MODULE LUGS OR RACKING INTEGRATED GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED USING UL-LISTED LAY-IN LUGS. 3 INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 "GROUNDING AND BONDING" WHEN USED WITH PROPOSED PV MODULE. 4 IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE GROUNDING ELECTRODE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. 5 AC SYSTEM GROUNDING ELECTRODE CONDUCTOR (GEC) SHALL BE A MINIMUM SIZE #8AWG WHEN INSULATED, #6AWG IF BARE WIRE. 6 EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC ARTICLE 690.45, AND BE A MINIMUM OF #10AWG WHEN NOT EXPOSED TO DAMAGE, AND #6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE 7 GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLOR CODED GREEN, OR MARKED GREEN IF #4AWG OR LARGER GENERAL ELECTRICAL NOTES 1 UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 2 CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE 310.10 (D). 3 CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). C1 - AC COMBINER (ENPHASE IQ COMBINER 3) SW1 - DISCONNECT (EATON DG222URB ) MSP - MAIN SERVICE PANEL SEE NOTE NO. 4 (MSP) EMERGENCY RESPONDER THIS SOLAR PV SYSTEM IS EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN THE ENTIRE PV SYSTEM. NFPA 111.12.2.1.1.1.1,11.12.2.1.4 AND NEC690.56(C)(1) AC COMBINER PANEL (C1) ! WARNING ! THIS EQUIPMENT FED BY MULTIPLE SOURCES. TOTAL RATING OF ALL OVERCURRENT DEVICES, EXCLUDING MAIN OVERCURRENT DEVICE SHALL NOT EXCEED AMPACITY OF BUSBAR. NEC705.12(B)(2)(3)(C) EACH DISCONNECTING MEANS FOR PHOTOVOLTAIC EQUIPMENT (SW1) ! WARNING ! ELECTRIC SHOCK HAZARD. TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION. NEC690.13(B) AC SOLAR DISCONNECT (SW1, CB4 IN MSP) PV SYSTEM DISCONNECT NEC690.13(B) AC DISCONNECT (SW1, CB4 IN MSP) MAXIMUM AC OPERATING CURRENT: 33.9A MAXIMUM AC OPERATING VOLTAGE: 240V NEC690.54 SOLAR BREAKER (MSP) MAIN BREAKER HAS BEEN RESIZED TO 175 AMPS. DO NOT UPSIZE BREAKER. ANY AC ELECTRICAL PANEL THAT IS FED BY BOTH THE UTILITY AND THE PHOTOVOLTAIC SYSTEM (MSP) ! WARNING ! DUAL POWER SOURCE. SECOND SOURCE IS PHOTOVOLTAIC SYSTEM. NEC705.12(B)(3) SOLAR BREAKER (MSP) ! WARNING ! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. NEC705.12(B)(2)(3)(B) LABELING NOTES 1 ALL PLAQUES AND SIGNAGE REQUIRED BY 2017 NEC AND 2018 NFPA 1 WILL BE INSTALLED AS REQUIRED. 2 LABELS, WARNING(S) AND MARKING SHALL COMPLY WITH ANSI Z535.4, WHICH REQUIRES THAT DANGER, WARNING, AND CAUTION SIGNS USED THE STANDARD HEADER COLORS, HEADER TEXT, AND SAFETY ALERT SYMBOL ON EACH LABEL. THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50% TALLER THAN THE BODY TEXT, IN ACCORDANCE WITH NEC 110.21(B). 3 A PERMANENT PLAQUE OR DIRECTORY SHALL BE INSTALLED PROVIDING THE LOCATION OF THE SERVICE DISCONNECTING MEANS AND THE PHOTOVOLTAIC SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME LOCATION IN ACCORDANCE WITH NEC 690.56(B). 4 LABEL(S) WITH MARKING, "TURN RAPID SHUTDOWN SWITCH TO THE 'OFF' POSITION TO SHUT DOWN THE ENTIRE PV SYSTEM," SHALL BE LOCATED WITHIN 3 FT OF SERVICE DISCONNECTING MEANS THE TITLE SHALL UTILIZE CAPITALIZED LETTERS WITH A MINIMUM HEIGHT OF 3/8” IN BLACK ON A RED BACKGROUND, AND REMAINING TEXT SHALL BE CAPITALIZED WITH A MINIMUM HEIGHT OF 3/16” IN BLACK ON WHITE BACKGROUND P-161530 GRID-TIED SOLAR POWER SYSTEM8528 COBBLESTONE DRFORT PIERCE, FL 34945SAFETY LABELS DOC ID:161530-199148-1 DATE:7/1/21 CREATOR: REVIEWER: REVISIONS PV-4 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 24.9FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS Q.PEAK DUO BLK ML-G9+ 380 DIMENSIONS (AREA) 72.4IN X 40.6IN X 1.3IN (20.4 SQ FT) WEIGHT 43LB MOUNTING SYSTEM PROPERTIES RAIL MODEL K2 CROSSRAIL 44-X ANCHOR MODEL K2 4000061 (FLASHED), 2.5IN AIR GAP FASTENING METHOD 3.0 INCH EMBEDMENT INTO RAFTERS WITH (1) 5/16IN DIA. FASTENER MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 10 43.0 429.9 MICROINVERTERS 10 1.1 10.8 LINEAR FEET OF RAIL 127 FT 0.5 59.5 ANCHORS 42 1.2 52.5 MISC. HARDWARE 16.9 16.9 TOTAL ARRAY WEIGHT 569.6 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 10 20.4 204.0 POINT LOAD (569.6 LBS / 42 ATTACHMENTS) 13.6 LBS DIST. LOAD (569.6 LBS / 204.0 SQFT)2.79 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7-16). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 4.2 FT = MAX(MIN(0.4 * 24.9 FT, 0.1 * 41.7 FT), 0.04 * 41.7 FT, 3 FT) P-161530 GRID-TIED SOLAR POWER SYSTEM8528 COBBLESTONE DRFORT PIERCE, FL 34945ATTACHMENT PLAN DOC ID:161530-199148-1 DATE:7/1/21 CREATOR: REVIEWER: REVISIONS PV-5.1 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 24.9FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS Q.PEAK DUO BLK ML-G9+ 380 DIMENSIONS (AREA) 72.4IN X 40.6IN X 1.3IN (20.4 SQ FT) WEIGHT 43LB MOUNTING SYSTEM PROPERTIES RAIL MODEL K2 CROSSRAIL 44-X ANCHOR MODEL K2 4000061 (FLASHED), 2.5IN AIR GAP FASTENING METHOD 3.0 INCH EMBEDMENT INTO RAFTERS WITH (1) 5/16IN DIA. FASTENER MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 3 43.0 129.0 MICROINVERTERS 3 1.1 3.2 LINEAR FEET OF RAIL 23 FT 0.5 10.6 ANCHORS 10 1.2 12.5 MISC. HARDWARE 4.8 4.8 TOTAL ARRAY WEIGHT 160.1 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 3 20.4 61.2 POINT LOAD (160.1 LBS / 10 ATTACHMENTS) 16.0 LBS DIST. LOAD (160.1 LBS / 61.2 SQFT)2.62 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7-16). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 4.2 FT = MAX(MIN(0.4 * 24.9 FT, 0.1 * 41.7 FT), 0.04 * 41.7 FT, 3 FT) P-161530 GRID-TIED SOLAR POWER SYSTEM8528 COBBLESTONE DRFORT PIERCE, FL 34945ATTACHMENT PLAN DOC ID:161530-199148-1 DATE:7/1/21 CREATOR: REVIEWER: REVISIONS PV-5.2 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 24.9FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS Q.PEAK DUO BLK ML-G9+ 380 DIMENSIONS (AREA) 72.4IN X 40.6IN X 1.3IN (20.4 SQ FT) WEIGHT 43LB MOUNTING SYSTEM PROPERTIES RAIL MODEL K2 CROSSRAIL 44-X ANCHOR MODEL K2 4000061 (FLASHED), 2.5IN AIR GAP FASTENING METHOD 3.0 INCH EMBEDMENT INTO RAFTERS WITH (1) 5/16IN DIA. FASTENER MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 9 43.0 386.9 MICROINVERTERS 9 1.1 9.7 LINEAR FEET OF RAIL 116 FT 0.5 54.4 ANCHORS 42 1.2 52.5 MISC. HARDWARE 16.9 16.9 TOTAL ARRAY WEIGHT 520.5 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 9 20.4 183.6 POINT LOAD (520.5 LBS / 42 ATTACHMENTS) 12.4 LBS DIST. LOAD (520.5 LBS / 183.6 SQFT)2.84 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7-16). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 4.2 FT = MAX(MIN(0.4 * 24.9 FT, 0.1 * 41.7 FT), 0.04 * 41.7 FT, 3 FT) P-161530 GRID-TIED SOLAR POWER SYSTEM8528 COBBLESTONE DRFORT PIERCE, FL 34945ATTACHMENT PLAN DOC ID:161530-199148-1 DATE:7/1/21 CREATOR: REVIEWER: REVISIONS PV-5.3 ROOF PROPERTIES ROOF MATERIAL COMPOSITION SHINGLE (1 LAYER) SLOPE 6/12 (26.6°) MEAN ROOF HEIGHT 24.9FT DECK SHEATHING 15/32" OSB CONSTRUCTION RAFTERS (2X4'S), 24IN OC MODULE MECHANICAL PROPERTIES MODEL Q-CELLS Q.PEAK DUO BLK ML-G9+ 380 DIMENSIONS (AREA) 72.4IN X 40.6IN X 1.3IN (20.4 SQ FT) WEIGHT 43LB MOUNTING SYSTEM PROPERTIES RAIL MODEL K2 CROSSRAIL 44-X ANCHOR MODEL K2 4000061 (FLASHED), 2.5IN AIR GAP FASTENING METHOD 3.0 INCH EMBEDMENT INTO RAFTERS WITH (1) 5/16IN DIA. FASTENER MAX. ALLOW. RAIL SPAN 48.0IN (ZONES 1, 2, AND 3) MAX. MOUNT SPACING 48.0IN (ZONES 1, 2, AND 3) MAX. ALLOW. CANTILEVER 16.0IN (ZONES 1, 2, AND 3) GROUNDING AND BONDING INTEGRAL GROUNDING CERTIFIED TO UL 2703 REQUIREMENTS DEAD LOAD CALCULATIONS LOAD QTY LBS TOTAL LBS MODULES 6 43.0 257.9 MICROINVERTERS 6 1.1 6.5 LINEAR FEET OF RAIL 46 FT 0.5 21.6 ANCHORS 19 1.2 23.7 MISC. HARDWARE 8.8 8.8 TOTAL ARRAY WEIGHT 318.6 LBS AREA NAME QTY SQFT TOTAL SQFT MODULES 6 20.4 122.4 POINT LOAD (318.6 LBS / 19 ATTACHMENTS) 16.8 LBS DIST. LOAD (318.6 LBS / 122.4 SQFT)2.6 PSF NOTES 1 RAFTER LOCATIONS ARE APPROXIMATE. ACTUAL LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED TO ADJUST MOUNT LOCATIONS. IN NO CASE SHALL THE MOUNT SPACING EXCEED "MAX. MOUNT SPACING" 2 PER ENGINEERING, CANTILEVER ("RAIL END OVERHANG") "IS NOT TO EXCEED 33% OF ACCEPTABLE RAIL SPAN" DEFINED IN THIS DOCUMENT AS "MAX. ALLOW. RAIL SPAN". WIND ZONE I WIND ZONE II WIND ZONE III DISTANCE α IS EQUAL TO 10% OF THE BUILDING'S LEAST HORIZONTAL DIMENSION OR 40% OF THE MEAN ROOF HEIGHT, WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF THE LEAST HORIZONTAL DIMENSION OR 3 FEET (ACSE 7-16). THESE SETBACKS ARE APPLIED TO THE BUILDING FOOTPRINT AND PROJECTED TO THE PLANES OF ROOF CORNERS, RAKES, HIPS, EAVES, MANSARDS, AND RIDGES OF ROOF FACES. α = MAX(MIN(0.4 * MEAN ROOF HEIGHT, 0.1 * LEAST HORIZONTAL DIMENSION), 0.04 * LEAST HORIZONTAL DIMENSION, 3 FT) 4.2 FT = MAX(MIN(0.4 * 24.9 FT, 0.1 * 41.7 FT), 0.04 * 41.7 FT, 3 FT) P-161530 GRID-TIED SOLAR POWER SYSTEM8528 COBBLESTONE DRFORT PIERCE, FL 34945ATTACHMENT PLAN DOC ID:161530-199148-1 DATE:7/1/21 CREATOR: REVIEWER: REVISIONS PV-5.4 P-161530 GRID-TIED SOLAR POWER SYSTEM8528 COBBLESTONE DRFORT PIERCE, FL 34945ATTACHMENT DETAILS DOC ID:161530-199148-1 DATE:7/1/21 CREATOR: REVIEWER: REVISIONS PV-6 GENERAL NOTES 1 ACCESS AND SPACING REQUIREMENTS SHALL BE REQUIRED TO PROVIDE EMERGENCY ACCESS TO THE ROOF, PROVIDE PATHWAYS TO SPECIFIC AREAS OF THE ROOF, PROVIDE FOR SMOKE VENTILATION OPPORTUNITY AREAS, AND TO PROVIDE EMERGENCY EGRESSION FROM THE ROOF. THE AHJ SHALL BE PERMITTED TO REDUCED OR MODIFY ROOF ACCESS BASED UPON FIRE DEPARTMENT VENTILATION PROCEDURES OR ALTNERATIVE METHODS THAT ENSURE ADEQUATE FIRE DEPARTMENT ACCESS, PATWAYS, AND SMOKE VENTILATION. (NFPA 1 11.12.2.2.1) 2 NOT LESS THAN TWO 36 IN. (914 MM) WIDE PATHWAYS ON SEPARATE ROOF PLANES, FROM GUTTER TO RIDGE, SHALL BE PROVIDED ON ALL BUILDINGS. ONE PATHWAY SHALL BE PROVIDED ON THE STREET OR DRIVEWAY SIDE OF THE ROOF. FOR EACH ROOF PLAN WITH A PV ARRAY, A 36 IN. (914 MM) WIDE PATHWAY FROM GUTTER TO RIDGE SHALL BE PROVIDED ON THE SAME ROOF PLANE AS THE PV ARRAY, ON AN ADJACENT ROOF PLANE OR STRADDLING THE SAME AND ADJACENT ROOF PLANES. PATHWAYS SHALL BE LOCATED IN AREAS WITH MINIMAL OBSTRUCTIONS SUCH AS VENT PIPES, CONDUIT, OR MECHANICAL EQUIPMENT. (NFPA 1 11.12.2.2.2.1) 3 FOR PV ARRAYS OCCUPYING UP TO 33 PERCENT OF THE PLAN VIEW ROOF AREA, A MINIMUM 18 IN. (457 MM) PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. FOR PV ARRAYS OCCUPYING MORE THAN 33 PERCENT OF THE PLAN VIEW ROOF AREA, A MINIMUM OF 36 IN. (914 MM) PATHWAY SHALL BE PROVIDED ON EITHER SIDE OF A HORIZONTAL RIDGE. (NFPA 1 11.12.2.2.2.2) ROOF ACCESS POINT 2.0 FT. WIDE FIRE ACCESS PATHWAY PV MODULES INSTALLED ON ROOF WITH K2 CROSSRAIL MOUNTING SYSTEM. THE MOUNTING SYSTEM IS UL 1703 CLASS A FIRE RATED ON A 6/12 SLOPED ROOF WHEN INSTALLED WITH TYPE 1, 2, OR 3 MODULES. THE Q-CELLS Q.PEAK DUO BLK ML-G9+ 380 IS TYPE 2. 2.0 FT. WIDE FIRE ACCESS PATHWAY, PER NFPA 1 11.12.2.2.2.1 ROADWAY TOTAL PLAN VIEW ARRAY AREA IS 512.5 SQ.FT, WHICH REPRESENTS 23.1% OF TOTAL PLAN VIEW ROOF AREA (2216.8 SQ.FT) THIS SYSTEM UTILIZES MICROINVERTERS. THERE ARE NO DC CIRCUITS OUTSIDE OF THE ARRAY PERIMETER OR INSIDE THE BUILDING. ALL ARRAY CIRCUITS SHALL BE ROUTED THROUGH THE INTERIOR OF THE BUILDING, AND WHERE POSSIBLE, ALONG THE BOTTOM OF LOAD BEARING MEMBERS. NO CONDUIT SHALL BE INSTALLED ABOVE THE ROOF. P-161530 GRID-TIED SOLAR POWER SYSTEM8528 COBBLESTONE DRFORT PIERCE, FL 34945FIRE SAFETY PLAN DOC ID:161530-199148-1 DATE:7/1/21 CREATOR: REVIEWER: REVISIONS PV-7 The Enphase IQ Combiner 3™ with Enphase IQ Envoy™ consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre-wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly.Enphase IQ Combiner 3(X-IQ-AM1-240-3)To learn more about Enphase offerings, visit enphase.comData SheetEnphase NetworkingSmart• Includes IQ Envoy for communication and control• Flexible networking supports Wi-Fi, Ethernet, or cellular• Optional AC receptacle available for PLC bridge• Provides production metering and optional consumption monitoringSimple• Reduced size from previous combiner• Centered mounting brackets support single stud mounting• Supports back and side conduit entry• Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included)• 80 A total PV or storage branch circuitsReliable• Durable NRTL-certified NEMA type 3R enclosure• Five-year warranty• UL listedTo learn more about Enphase offerings, visit enphase.com© 2018 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner. 2018-09-13MODEL NUMBERIQ Combiner 3 X-IQ-AM1-240-3IQ Combiner 3 with Enphase IQ Envoy™ printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%).ACCESSORIES and REPLACEMENT PARTS (not included, order separately)Enphase Mobile Connect™CELLMODEM-03 (4G / 12-year data plan)CELLMODEM-01 (3G / 5-year data plan)CELLMODEM-M1 (4G based LTE-M / 5-year data plan)Plug and play industrial grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.)Consumption Monitoring* CTCT-200-SPLITSplit core current transformers enable whole home consumption metering (+/- 2.5%).Circuit BreakersBRK-10A-2-240BRK-15A-2-240BRK-20A-2P-240Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers.Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01Power line carrier (communication bridge pair), quantity 2XA-PLUG-120-3Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01)XA-ENV-PCBA-3Replacement IQ Envoy printed circuit board (PCB) for Combiner 3ELECTRICAL SPECIFICATIONSRatingContinuous dutySystem voltage120/240 VAC, 60 HzEaton BR series busbar rating125 AMax. continuous current rating (output to grid)65 AMax. fuse/circuit rating (output)90 ABranch circuits (solar and/or storage)Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)Max. continuous current rating (input from PV)64 AMax. total branch circuit breaker rating (input)80A of distributed generation / 90A with IQ Envoy breaker includedProduction Metering CT200 A solid core pre-installed and wired to IQ EnvoyMECHANICAL DATADimensions (WxHxD)49.5 x 37.5 x 16.8 cm (19.5” x 14.75” x 6.63”). Height is 21.06" (53.5 cm with mounting brackets).Weight7.5 kg (16.5 lbs)Ambient temperature range-40º C to +46º C (-40º to 115º F)CoolingNatural convection, plus heat shieldEnclosure environmental ratingOutdoor, NRTL-certified, NEMA type 3R, polycarbonate constructionWire sizes• 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors• 60 A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors• Neutral and ground: 14 to 1/0 copper conductorsAlways follow local code requirements for conductor sizing.AltitudeTo 2000 meters (6,560 feet)INTERNET CONNECTION OPTIONSIntegrated Wi-Fi802.11b/g/nEthernetOptional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) CellularOptional, CELLMODEM-01 (3G) or CELLMODEM-03 (4G) or CELLMODEM-M1 (4G based LTE-M) (not included)COMPLIANCECompliance, CombinerUL 1741 CAN/CSA C22.2 No. 107.147 CFR, Part 15, Class B, ICES 003Production metering: ANSI C12.20 accuracy class 0.5 (PV production)Compliance, IQ EnvoyUL 60601-1/CANCSA 22.2 No. 61010-1 * Consumption monitoring is required for Enphase Storage Systems. Enphase IQ Combiner 3 The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency.Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software.IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Enphase IQ 7 and IQ 7+MicroinvertersTo learn more about Enphase offerings, visit enphase.comData SheetEnphase MicroinvertersRegion: AMERICASEasy to Install• Lightweight and simple• Faster installation with improved, lighter two-wire cabling• Built-in rapid shutdown compliant (NEC 2014 & 2017)Productive and Reliable• Optimized for high powered 60-cell and 72-cell* modules• More than a million hours of testing• Class II double-insulated enclosure• UL listedSmart Grid Ready• Complies with advanced grid support, voltage and frequency ride-through requirements• Remotely updates to respond to changing grid requirements• Configurable for varying grid profiles• Meets CA Rule 21 (UL 1741-SA)* The IQ 7+ Micro is required to support 72-cell modules.1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.To learn more about Enphase offerings, visit enphase.com© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-11-19INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-USIQ7PLUS-72-2-US / IQ7PLUS-72-B-USCommonly used module pairings¹235 W - 350 W +235 W - 440 W +Module compatibility60-cell PV modules only60-cell and 72-cell PV modulesMaximum input DC voltage48 V60 VPeak power tracking voltage27 V - 37 V27 V - 45 VOperating range16 V - 48 V16 V - 60 VMin/Max start voltage22 V / 48 V22 V / 60 VMax DC short circuit current (module Isc)15 A15 AOvervoltage class DC portIIIIDC port backfeed current0 A0 APV array configuration1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ 7 MicroinverterIQ 7+ MicroinverterPeak output power250 VA295 VAMaximum continuous output power240 VA290 VANominal (L-L) voltage/range²240 V / 211-264 V208 V / 183-229 V240 V / 211-264 V208 V / 183-229 VMaximum continuous output current1.0 A (240 V)1.15 A (208 V)1.21 A (240 V)1.39 A (208 V)Nominal frequency60 Hz60 HzExtended frequency range47 - 68 Hz47 - 68 HzAC short circuit fault current over 3 cycles5.8 Arms5.8 ArmsMaximum units per 20 A (L-L) branch circuit³16 (240 VAC)13 (208 VAC)13 (240 VAC)11 (208 VAC)Overvoltage class AC portIIIIIIAC port backfeed current0 A0 APower factor setting1.01.0Power factor (adjustable)0.85 leading ... 0.85 lagging0.85 leading ... 0.85 laggingEFFICIENCY@240 V@208 V@240 V@208 VPeak efficiency97.6 %97.6 %97.5 %97.3 %CEC weighted efficiency97.0 %97.0 %97.0 %97.0 %MECHANICAL DATAAmbient temperature range-40ºC to +65ºCRelative humidity range4% to 100% (condensing)Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US)MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter)Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US)Friends PV2 (MC4 intermateable). Adaptors for modules with MC4 or UTX connectors:- PV2 to MC4: order ECA-S20-S22- PV2 to UTX: order ECA-S20-S25Dimensions (WxHxD)212 mm x 175 mm x 30.2 mm (without bracket)Weight1.08 kg (2.38 lbs)CoolingNatural convection - No fansApproved for wet locationsYesPollution degreePD3EnclosureClass II double-insulated, corrosion resistant polymeric enclosureEnvironmental category / UV exposure ratingNEMA Type 6 / outdoorFEATURESCommunicationPower Line Communication (PLC)MonitoringEnlighten Manager and MyEnlighten monitoring options.Both options require installation of an Enphase IQ Envoy.Disconnecting meansThe AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690.ComplianceCA Rule 21 (UL 1741-SA)UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions.Enphase IQ 7 and IQ 7+ Microinverters We support PV systemsFormerly Everest Solar SystemsWe support PV systemsFormerly Everest Solar Systemsk2-systems.comCrossRail SystemPRODUCT SHEET THigh quality, German-engineered system for residential and commercial installations T4 rail sizes available to suit all structural conditions TUniversal components for all rail types TUse 2 innovative components to turn this system into Shared Rail or Tilt Up TMK3 technology provides highest rail engagement TRoof attachments for all roof types T100% code compliant, structural validation for all solar states TFast installation with minimal component count result in low total installed costWe support PV systemsFormerly Everest Solar SystemsPart NumberDescription4000019CrossRail 44-X, 166", Mill4000020CrossRail 44-X, 166", Dark4000021CrossRail 44-X, 180", Mill4000022CrossRail 44-X, 180", DarkCrossRail 44-XPart NumberDescription4000662CrossRail 48-X, 166", Mill4000663CrossRail 48-X, 166", Dark4000675CrossRail 48-X, 180", Mill4000665CrossRail 48-X, 180", DarkCrossRail 48-XPart NumberDescription4000695CrossRail 48-XL, 166", Mill4000705CrossRail 48-XL, 166", DarkCrossRail 48-XLPart NumberDescription4000508CrossRail 80, 168", MillCrossRail 80CrossRail Mid ClampPart NumberDescription4000429CR EC Silver 30-50mm, SR 30-45mm4000430CR EC Dark 30-50mm, SR 30-45mm4000003SR EC Silver 46-50mm4000004SR EC Dark 46-50mmCrossRail End ClampPart NumberDescription4000050-HYeti Hidden EC for CR, Mill, 13mm HexYeti Clamp Part NumberDescription4005344CrossRail EC Silver, AL 32-33mm4005169CrossRail EC Silver, AL 34-36mm4005290CrossRail EC Silver, AL 37-38mm4005170CrossRail EC Silver, AL 39-41mm4005291CrossRail EC Silver, AL 42-44mm4005171CrossRail EC Silver, AL 45-47mm4005292CrossRail EC Silver, AL 48mm4005172CrossRail EC Silver, AL 49-50mmAluminum End ClampPart NumberDescription4000051Rail Connector CR 44-X, Set, Mill4000052Rail Connector CR 44-X, Set, Dark4000385RailConn CR48-X,48-XL Struct Set, Mill4000386RailConn CR48-X,48-XL Struct Set, Dark4001196Rail Connecctor UL 2703 Set, CR80, MillCrossRail Rail ConnectorPart NumberDescription4000630L-Foot Slotted Set, Mill4000631L-Foot Slotted Set, Dark4000080T-Foot X, Set, MillL-Foot & T-FootPart NumberDescription4000034Flat Tile Hook4001294Tile Hook 3S4000521SingleHookTile HooksPart NumberDescription4000016Standing Seam PowerClamp, Mini4000017Standing Seam PowerClamp, StandardStanding Seam PowerClampsPart NumberDescription4000601-HCR MC Silver, 30-47mm, 13mm Hex4000602-HCR MC Dark, 30-47mm, 13mm Hex4000688-HSR MC Silver, 30-50mm, 13mm Hex4000689-HSR MC Silver, 30-50mm, 13mm Hex2Components TEverest’s very own comp shingle flashing and mount! TBest in class - 3 stages of waterproofing TAll CrossRail hardware included and preassembled TUL 441 Section 27 Rain test TTAS 100-95 Wind driven rain testButyl gasket seals L-Foot - Flashing con-nectionEPDM sealing washer on lag boltDome provides fully encapsulated raised sealPart NumberDescription4000057EverFlash XP Kit, Mill LF, Dark Flash4000060EverFlash XP Comp Kit, Dark4000061EverFlash XP Comp Kit, Millwww.everest-solarsystems.comEverFlash XP CompEverFlash XP Comp Product Sheet US03 | 0120 · Subject to change · Product illustrations are exemplary and may differ from the original. EverFlash XP Comp FlashingPart NumberDescription4000037EverFlash XP Flashing 24ga Galv, Dark4000056EverFlash XP Flashing 24ga Galv, MillComponents EverFlash XP L-Foot and Butyl GasketPart NumberDescription4000036EverFlash XP L-Foot Mill4000038EverFlash XP L-Foot Dark4000063XP Butyl Gasket, LfootLag Bolt and Washer TMaterial: stainless steel TEPDM backed washer TPreassmbled TMaterial: aluminum TFinish: mill or dark TT-Bolt for CrossRail included TMaterial: galvalume TFinish: mill or dark