Loading...
HomeMy WebLinkAboutAPPROVED 2407 38th Street Revision 6-7-21 DETAIL footerOFFICE USE ONLY: DATE FILED: 6/14/21 REVISION FEE: LOCATION/SITE ADDRESS: 2407 38th St Fort Pierce PERMIT # 2104-0168 RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT REVISIONS: After inspection off footer, engineer detail on repairing/redoing footer CONTRACTOR INFORMATION: STATE Of FL REG./CERT. #: CGC1515114 BUSINESS NAME: Sunrise City Concrete Service QUALIFIERS NAME: Roderick Waller ADDRESS: 130 S Indian River Drive Suite 202 CITY: Fort Pierce STATE: FL PHONE (DAYTIME): 772-201-2850 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME: STATE: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: PHONE (DAYTIME): SLCCC: 9123109 Revised 06130/17 STATE: ST. LUCIE CO CERT. #: ZIP: 34947 FAX: 772-907-0420 r ram: FAX: ZIP: ZIP: DESIGNWEST ENGINEERS AND ASSOCIATES INC. 111 MONUMENT AVE.,KISSIMMEE,FL.34741 DESIGNWESTASSOC@AOL.COM Revision 6-7-21 Property Address: 2407 38th Street Fort Pierce FL 34981 Scope of work Install Footer 12"x16" Epoxy 1 #5 Rod and Pour 8"x16" C.M.0 PROVIDED SIMSON H5 @32"OC.STUD TO 2X6 PROVIDED SIMSON LSTA 24 @32"OC.STUD TO CMU EXIST. 2X4 PLATE EXIST. 2X6 PERM.JOIST CONTS—� PROVIDED 2- 3/ 16 X1.5" TAPCON @32"OC. TO CMU — PROVIDED DRILL AND EPDXY 1 #5 ROD W/SIMPSON #ET INTO CMU FIN.I GRADE SCALE: 3/4"=V-0" .j DESIGN NEST ASSO IATE5, INC. EXIST 2X4 STUDS @16" OC. 2X8 PERM.JOIST CONTS. 2X8 PERM.SHIM XISTING CRAWEL SPACE TYP.16"X32" CRAWEL SPACE X 16" C.M.U. COMP. @ 95% J\\\\\\\P1EGAIVz J 5�,.•��CENgF . � i NO. 33134 STATE OF ////////ONA1 ; NOTE: REINFORCEMENT BARS ARE TO BE #5 BAR GRADE 40 UNLESS OTHERWISE NOTED. FOOTING ARE TO BE DESIGNED FOR A MINIMUM SOIL BEARING CAPACITY @ 95% Digitally signed by Wayne Gandy Reason: Printed copies of this document are not valid. Signatures hereon must be veriied This docoment has been electronically sealed by Wayne Gandy, P.E. Date: 2021.06.08 10:11:31-04'00' ULTIMATE DESIGN WIND SPEED= 160 MPH NOMINAL DESIGN WIND SPEED= 139 MPH RISK CATEGORY= B RISK EXPOSSURE= C SUNRISE CITY CHDO.INC. COMPONENT & CADDING = ASCE7-10 BUILDING H.<60FT LOW RISE PROJECT: 2407 38TH STREET EXPOSSURE= .18 FORT PIERCE, FL. ENGINGEERING DESIGN CRITERIA MEETS OR EXCEEDS 2020 7TH EDITION FLORIDA BUILDING CODE,SECTION R601. FBC. 1603.1 FACTOR= 1.0 INTERNAL PRESSURE COEFFICIENT= + .25. 3. WINDOWS, DOORS, AND CLADDING ARE TO BE DESIGNED TO MEET CONSTRUCTION 160 MPH WIND SPEED WITH 3 SECOND GUST FBC 107.3.5