Loading...
HomeMy WebLinkAboutApproved Ground EquipmentT • •Mobile ER i..ui... PP. -- E, L: J..' A2PO04513 MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 EXCALIBUR INSTALLATION LOCAL MAP PROPERTY SUMMARY PROJECT DESCRIPTION INDEX OF DRAWINGS J u FOLIO 1. THE WIRELESS COMMUNICATIONS FACILITY IS NOT INTENDED FOR HUMAN OCCUPANCY. 1406-413-0003-000-8 SHT. NO. RE V. om' NO. T1 TITLE SHEET 0 2. THIS FACILITY DOES NOT REQUIRE POTABLE WATER AND PROPERTY OWNER WILL NOT PRODUCE ANY SEWAGE. T2 GENERAL NOTES 0 M.Nleh— MARY JANE SPAIN (TR) 3. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS PO BOX 1149 AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY HOBE SOUND, FL 33475 NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE Cl COMPOUND PLAN p C2 EQUIPMENT PLANS p LATITUDEPROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. 0 0 4. THE SCOPE OF WORK CONSISTS OF MODIFYING THE EXISTING 27,546333' N WIRELESS INSTALLATION: 0 AlIanlR. Hardzcapes LONGITUDE REMOVAL OF (2) EXISTING EQUIPMENT CABINETS REMOVAL OF (9) EXISTING ANTENNAS 80.368583' W REMOVAL OF (9) EXISTING RRUS rE2UTILITY 0 AL AND GROUNDING NOTES 0 OUTING PLAN 0 7 -� ZONING JURISDICTION REMOVAL OF (1) EXISTING COVPS REMOVALOF (3) EXISTING ANTENNA MOUNTS ST LUCIE COUNTY INSTALLATION OF (2) PROPOSED EQUIPMENT CABINETS INSTALLATION OF (2) PROPOSED HYBRID CABLES E3 UTILITY ROUTING PLAN p E4 ELECTRICAL DETAILS p INSTALLATION OF (6) PROPOSED ANTENNAS INSTALLATION OF (9) PROPOSED RRUS E5 GROUNDING DETAILS 0 INSTALLATION OF (3) PROPOSED ANTENNA MOUNTS INSTALLATION OF (1) PROPOSED SERVICE LIGHT i.r�pl Q eat . I VICINITY MAP I CODE COMPLIANCE qp m r ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN = ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES `4 AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. FLORIDA BUILDING CODE, 7th EDITION (2020). 2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70-17, NATIONAL ELECTRICAL CODE, 2017 EDITION. 3. ASCE 7-16. 4. TIA-222-H WITH APPLICABLE STANDARDS. 5. LIFE SAFETY CODE NFPA-101-2018. 6. FLORIDA FIRE PREVENTION CODE, 7th EDITION (2020). 7. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) 360-16 AND 341-16. 8. UNDERWRITERS LABORATORIES (U.L.) APPROVED ELECTRICAL PRODUCTS. 9. LOCAL JURISDICTIONAL REQUIREMENTS. 10. CITY/COUNTY ORDINANCES. DESIGN CRITERIA BASIC WIND SPEED: 160 MPH (ULTIMATE, 3-SECOND GUST) 202 EXPOSURE: C RISK CATEGORY: II OPEN STRUCTURE 1 CALL 48 HOURS BEFORE YOU DIG IT'S THE LAW ! 1-800-432-4770 SUNSHINE STATE ONE CALL OF FLORIDA, INC. REV DATE DESCRIPTION A 4/6/21 PRELIMINARY B 4/9/21 REVISED C 4/16/21 REVISED 0 5/7/21 FOR PERMIT APX PROJECT NO.: 21-D270.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERM SSION OF THE OWNER. ax ENGINEERING 14471 MIRAMAR PARKWAY, SURE 202 MIRAMAR. FL 33027 (954) 744-1538 CERTIFICATE OF AUTHORIZATION 31948 T Mobile a iijitallyrie d by I ! ,..,..z ...• i Date: ro° 1 05.07 4 d`S;V�OR10� �•` dNAL4NC`' I f%AI^^ A2P0045B MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 SHEL-1 NAME TITLE SHEET T1 1. FOR THE PURPOSES OF THESE CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: 1. THE APPROPRIATE UTILITY LOCATING SERVICES SHALL BE CONTACTED PRIOR TO THE START OF CONSTRUCTION IN ORDER TO VERIFY THE OWNER - T-MOBILE USA EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. ENGINEER - APX ENGINEERING GROUP, LLC. 2. THE INSTALLATION OF NEW UTILITIES SHALL BE COORDINATED WITH LOCAL AUTHORITIES. CONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) 3. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHERE ENCOUNTERED IN THE WORK, SHALL BE PROTECTED AT 2. PRIOR TO SUBMITTING HIS BID, THE CONTRACTOR SHALL VISIT THE JOB SITE IN ORDER TO (1) VERIFY ALL EXISTING CONDITIONS, (2) ALL TIMES. WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK, SUCH UTILITIES SHALL BE RELOCATED AS DIRECTED BY THE CONSTRUCTION MANAGER. EXTREME CAUTION SHALL BE USED WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. CONFIRM WHETHER ALL DIMENSIONS ARE AS SHOWN ON THE PLANS AND (3) CONFIRM WHETHER THE WORK MAY BE ACCOMPLISHED AS SHOWN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER. 4. RUBBISH, STUMPS, DEBRIS, STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 3. A 20-FOOT HORIZONTAL CLEARANCE DISTANCE SHALL BE MAINTAINED FROM ALL EXISTING POWER LINES. 5. ALL EXISTING INACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES THAT INTERFERE WITH THE EXECUTION OF THE WORK SHALL 4. THE CONTRACTOR'S USE OF A CONSTRUCTION STAGING AREA SHALL BE COORDINATED WITH THE OWNER WELL IN ADVANCE OF THE BE REMOVED AND/OR CAPPED, PLUGGED OR OTHERWISE DISCONTINUED AT POINTS THAT WILL NOT INTERFERE WITH THE EXECUTION OF CONSTRUCTION START DATE. THE WORK, SUBJECT TO THE APPROVAL OF THE LANDLORD AND/OR LOCAL UTILITIES. 5. LABOR, MATERIAL, TOOLS, EQUIPMENT, TRANSPORTATION AND TEMPORARY POWER SERVICES NECESSARY FOR AND INCIDENTAL TO 6. DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION SHALL BE MINIMIZED. COMPLETION OF ALL WORK SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS AND/OR AS SPECIFIED HEREIN. LABOR AND MATERIALS 7. ANY AREAS OF THE CONSTRUCTION SITE DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY, SHALL SHALL BE FURNISHED AS REQUIRED FOR COMPLETE SYSTEMS, INCLUDING ALL ELEMENTS OBVIOUSLY OR REASONABLY INCIDENTAL TO A BE GRADED TO A UNIFORM SLOPE. SUCH GRADING SHALL CAUSE SURFACE WATER TO FLOW AWAY FROM ANY EQUIPMENT SHELTER AND COMPLETE INSTALLATION, WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS. TOWER AREAS AND THE SOIL SHALL BE STABILIZED TO PREVENT EROSION. EROSION CONTROL MEASURES,IF REQUIRED DURING 6. FOR TASKS REQUIRED TO BE PERFORMED BUT NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS, THE CONTRACTOR CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL. SHALL NOT START WORK ON SUCH TASKS WITHOUT HAVING RECEIVED WRITTEN AUTHORIZATION FROM THE CONSTRUCTION MANAGER TO 8. THE SUB -GRADE SHALL BE COMPACTED AND BROUGHT TO A UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. PROCEED. 7. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS OTHERWISE INDICATED 9' BACKFILL SHALL CONSIST OF CLEAN SAND FILL APPROVED FOR USE BY THE ENGINEER. NO UNAPPROVED MATERIAL WILL BE ALLOWED. BY DIMENSIONS OR DETAILS. EXACT EQUIPMENT LOCATIONS MAY BE MODIFIED AS REQUIRED BY ACTUAL FIELD CONDITIONS. IF THE CLEAN SAND FILL SHALL BE FREE OF ALL ROOTS, BOULDERS, OR OTHER DELETERIOUS MATERIAL. SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, CONTRACTOR SHALL PROPOSE AN ALTERNATIVE 10. THE CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EQUAL TO OR BETTER CONDITION THAN ORIGINAL. INSTALLATION FOR APPROVAL BY THE ENGINEER AND THE CONSTRUCTION MANAGER. B. THE CONTRACTOR SHALL OBTAIN, PAY FOR AND DELIVER ALL REQUIRED PERMITS, CERTIFICATES OF INSPECTION, INCLUDING UTILITY 11. SITE SIGNAGE SHALL BE PROVIDED IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR SUCH SIGNAGE AS MAY BE CONTAINED IN CONNECTION FEES, ETC., REQUIRED BY THE AUTHORITIES HAVING JURISDICTION AND SHALL DELIVER SUCH DOCUMENTS TO THE OWNER THESE DRAWINGS. PRIOR TO FINAL ACCEPTANCE OF THE WORK. SITE WORK NOTES 13 9. THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED TO AREAS OF NEW CONSTRUCTION. 10. ALL NECESSARY PROVISIONS SHALL BE MADE TO PROTECT EXISTING IMPROVEMENTS, LANDSCAPING, PAVING, CURBS, GALVANIZED1. SURFACES, ETC, AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO SAME RESULTING FROM THE CONSTRUCTION WORK. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE LATEST EDITION OF THE AISC "STEEL CONSTRUCTION MANUAL". ALL DISTURBED AND DAMAGED AREAS SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR BETTER UPON COMPLETION OF ALL WORK 2. MATERIAL: TO THE SATISFACTION OF THE CONSTRUCTION MANAGER. A. ALL STRUCTURAL STEEL WF BEAMS SHALL BE ASTM A992 AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND 11. THE FOLLOWING CLEANUP TASKS SHALL BE PERFORMED AS FOLLOWS: (1) ON A DAILY BASIS, KEEP THE GENERAL AREA CLEAN AND ASTM A153 STANDARDS. HAZARD FREE, REMOVING ALL WASTE, DEBRIS AND TRASH FROM THE SITE AND DISPOSING OF SAME IN A LEGAL MANNER. (2) UPON B. ALL STRUCTURAL PLATES, ANGLES, AND CHANNELS SHALL BE ASTM A36 AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM COMPLETION, LEAVE THE PREMISES IN A CLEAN CONDITION AND FREE FROM PAINT SPOTS, DUST, OR SMUDGES OF ANY NATURE. A123 AND ASTM A153 STANDARDS, UNLESS NOTED OTHERWISE. C. ALL TS MEMBERS SHALL BE ASTM A500 GRADE B (Fy=46ksi), gANDP "HOT. DIPPED" GALVANIZED,,IN #ICCORDANCE WITH ASTM A123 12. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE RESPECTIVE MANUFACTURER'S RECOMMENDATIONS EXCEPT AND ASTM A153 STANDARDS. WHERE IT IS SPECIFICALLY INDICATED OTHERWISE IN THE CONTRACT DOCUMENTS OR WHERE LOCAL CODES OR REGULATIONS TAKE D. ALL STRUCTURAL PIPE MEMBERS SHALL BE ASTM A500 GRADE-B (Fy=4'2ksrr�AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH PRECEDENCE. ASTM A123 AND ASTM A153 STANDARDS, UNLESS NOTED OTHE WISE„ E. ALL NON-STRUCTURAL PIPE MEMBERS SHALL BE ASTM CT 13. ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES, REGULATIONS AND A53 GRADE B. AND DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS. ORDINANCES. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES, RULES, REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY HAVING JURISDICTION OVER THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS 2 DESIGN, FABRICATION, AND CONSTRUCTION OF ALL CONNECTIONS SHALL CONFORM TO AISC STEEL CONSTRUCTION MANUAL. SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AS WELL AS LOCAL AND 3. WELDING: STATE CODES, ORDINANCES AND APPLICABLE REGULATIONS. A. ALL WELDS, WELDERS, AND WELD INSPECTIONS SHALL CONFORM TO THE REQUIREMENTS OF AWS D 1.1, LATEST REVISION. 14. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AT ALL TIMES, USING THE BEST SKILLS AND ATTENTION. HE SHALL BE B. ALL WELDS SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES. SOLELY RESPONSIBLE FOR ALL OF THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR C. ALL STEEL SHALL BE SPRAY GALVANIZED AFTER WELDING. COORDINATING ALL PORTIONS OF THE WORK, INCLUDING CONTACT AND COORDINATION WITH THE CONSTRUCTION MANAGER AND WITH THE 4. ALL BOLTS SHALL BE GALVANIZED '/." DIAMETER, A325-N, UNLESS NOTED OTHERWISE AND TIGHTENED TO A "SNUG TIGHT' CONDITION AS OWNER'S AUTHORIZED REPRESENTATIVE. DEFINED BY AISC. SECURE NUT WITH LOCKING WASHER. 15. WITHIN TEN (10) WORKING DAYS AFTER PROJECT COMPLETION, THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS -BUILT DRAWINGS, SWEEP TEST, CYLINDER TESTS, LIEN RELEASES, AND OTHER CLOSEOUT DOCUMENTATION AS REQUIRED BY THE OWNER. ALL 5. ANCHOR BOLTS SHALL CONFORM TO ASTM F1554 GRADE 36, UNLESS NOTED OTHERWISE. SYSTEMS SHALL BE COMPLETELY ASSEMBLED, TESTED, ADJUSTED AND DEMONSTRATED TO BE READY FOR OPERATION PRIOR TO THE OWNER'S ACCEPTANCE. 5. THE CONTRACTOR/STEEL FABRICATOR SHALL LOCATE ANY REINFORCEMENT IN THE STRUCTURAL MEMBERS IN SUCH A MANNER SO THAT THERE WILL NOT BE CONFLICT WITH THE REINFORCEMENT WHEN INSTALLING ANCHORS. THE ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTION. SITE WORK NOTES 1 7. THE CONTRACTOR/STEEL FABRICATOR SHALL CONFORM TO THE MINIMUM EDGE DISTANCE REQUIREMENTS IN ACCORDANCE WITH THE AISC MANUAL OF STEEL CONSTRUCTION. AS OUTLINED BELOW, THE CONTRACTOR SHALL INSPECT THE T-MOBILE EQUIPMENT AREA AND ACCESS PATHS TO THE EQUIPMENT FOR OSHA VIOLATIONS. VIOLATIONS SHALL BE CORRECTED. DISCREPANCIES OR QUESTIONS REGARDING THE OSHA SCOPE OF WORK SHALL BE DIRECTED TO 8. ALL STRUCTURAL STEEL SHALL BE FABRICATED TO FIT AT BOLTED CONNECTIONS WITHIN 1/16 INCH TOLERANCE. STRUCTURAL STEEL SHALL THE T-MOBILE FM. NOT BE FLAME CUT UNDER ANY CIRCUMSTANCES WITHOUT APPROVAL OF THE ENGINEER. 1. RF RADIATION SIGNS SHALL BE INSTALLED AT ROOFTOP DOORS AND EACH SECTOR. 9. THE CONTRACTOR/STEEL FABRICATOR SHALL CAP OR SEAL ALL PIPES AS REQUIRED TO PREVENT WATER INTRUSION. 2. HOLES IN A PLATFORM WALKING SURFACES SHALL BE COVERED AND SECURED WITH CARRIAGE BOLTS. 10. THE CONTRACTOR/STEEL FABRICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO ANY STEEL FABRICATION. AT THE 3. INSTALL A NON -SLIP PATH LEADING TO THE T-MOBILE LEASE AREA. CONTRACTOR'S OPTION, FIELD SPLICES MAY BE USED FOR ERECTION PURPOSES. IF FIELD SPLICES ARE USED, THE SHOP DRAWINGS 4. HANDRAILS SHALL BE INSTALLED WITHIN 15' OF WORKING/WALKING SURFACES WHEN THE PARAPET OR THE EXPOSED WALKING EDGES SHALL INCLUDE ALL DETAILS FOR THE PROPOSED FIELD SPLICES. RAILINGS IS LESS THAN 42" ABOVE WALKING EDGE. 11. AT THE CONTRACTOR'S OPTION, SHOP WELDS MAY BE USED INSTEAD OF FIELD WELDS_ 5. TRIP HAZARDS NEAR WORKING/WALKING SURFACES SHALL BE MARKED WITH HIGH VISIBILITY PAINT OR TAPE. 6. INSTALL A CROSSOVER STAIR WHEN OBSTRUCTIONS PREVENT A DIRECT WALKING PATH TO THE T-MOBILE LEASE AREA. 12. SUBMIT ORIGINAL SHOP DRAWINGS, INCLUDING COMPLETE DETAILS, SCHEDULES OF FABRICATION AND ASSEMBLY, PROCEDURES, AND DIAGRAMS. INCLUDE DETAILS OF CUTS, CONNECTIONS, CAMBER, HOLE, AND OTHER PERTINENT DATA. INDICATE WELDS BY STANDARD AWS 7. PLATFORM LADDERS SHALL HAVE A CHAIN AT THE TOP WHICH CAN BE SECURED TO PREVENT ACCIDENTAL FALLS. A2.1 AND A2.4 SYMBOLS, AND SHOW SIZE, LENGTH, AND TYPE OF WELD_ PROVIDE SETTING DRAWINGS, TEMPLATES, AND DIRECTIONS FOR 8. OVERHEAD OBSTRUCTIONS NEAR WORKING AND WALKING SURFACES THAT REQUIRE A PERSON TO DUCK SHALL BE COVERED WITH HIGH INSTALLATION OF ANCHOR BOLTS AND OTHER ANCHORAGES TO BE INSTALLED AS WORK OF OTHERS' SECTIONS. VISIBILITY PAINT OR TAPE. 9. LIGHTS NEAR THE ROOFTOP DOOR AND OR LEASE AREA SHALL BE VERIFIED AND MADE FUNCTIONAL FOR AFTER-HOURS WORK. 10. THERE SHOULD BE NO SCREW THAT CAUSE A PENETRATION INTO ANY CABINETS THAT ARE NOT FACTORY PROVIDED. T-MOBILE STANDARD SAFETY COMPLIANCE NOTES L21 STRUCTURAL STEEL NOTES 4 REV DATE DESCRIPTION A 4/6/21 PRELIMINARY 8 4/9/21 REVISED C 4/16/21 REVISED 0 5/7/21 FOR PERMIT APX PROJECT NO.: 21-0270.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER, IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. a P=K ENGIN EERING GROUP 14471 MIRAMAR PARKWAY, SUITE 202 MIRAMAR, FL 33027 (954) 744-153B CERTIFICATE OF AUTHORIZATION 31948 T r . Mobilej- THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ELIEZER DIAZ, PE (#85219) ON MAY 7th, 2021 USING A DIGITAL SIGNATURE IN ACCORDANCE WITH F.A.C. 611015-23.004, WITH A DIGITAL CERTIFICATE ISSUED BY ENTRUST, INC. PLEASE REFERENCE THE COVER PAGE TO VIEW THE SIGNATURE AND VERIFY ITS PROPERTIES. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES A2P0045B MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 SHEET NAME GENERAL NOTES SHEET NUMBER T2 REV DATE DESCRIPTION A 4/6/21 PRELIMINARY B 4/9/21 REVISED C 4/16/21 REVISED 0 5/7/21 FOR PERMIT I APX PROJECT NO.: 21-0270.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN R IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. A apA E N G I N E E R I N G G R O U P 14471 MIRAMAR PARKWAY, SUITE 202 MIRAMAR, FL 33027 (954) 744-1538 CERTIFICATE OF AUTHORIZATION 31948 T - .Mobile THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ELIEZER DIAZ, PE (#85219) ON MAY 7th, 2021 USING A DIGITAL SIGNATURE IN ACCORDANCE WITH F.A.C. 61G15-23.004, WITH A DIGITAL CERTIFICATE ISSUED BY ENTRUST, INC. PLEASE REFERENCE THE COVER PAGE TO VIEW THE SIGNATURE AND VERIFY ITS PROPERTIES. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES A2P0045B MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 SHEET NAME COMPOUND PLAN SHEET NUMBER C1 -- I rx—X—x-7[�X—X—X—X—x—X—X -- EXISTING CHAIN LINK Ix FENCE I x X 1 I EXISTING 480't GUYED TOWER EXISTING T-MOBILE-- CABLE BRIDGE EXISTING T-MOBILE 6:1 x DIPLEXERTO� EXISTING T—MOBILE— RRU TO BE REMOVED r — MP. OF 3) X — —I IXEiT1NG T—MOBILE COUP TO BE REMOVED EXISTING T—WDSILE FCOA CABINET TO BE REMOVED EXISTING T-MOBILE SII'E�a SUPPORT CABINET TO x BE REMOVED I - EXISTING CABLE BRIDGE (TYP.) x •, Fr EXISTING x BUILDING x - x - x - x - x - x EXISTING BUILDING I EXISTING EQUIPMENT PLAN r x — x— x_x — x— x— x— x— x— X = R— x — r— v EXISTING CHAIN LINK x EXISTING T-MOBILE FENCE PROPOSI T-LSE DISCONNECT DISCONNECT TO BE REMOVED " EXISTING 480't GUYED TOWER i EXISTING T-MOBILE METER TO BE rf REMOVED EXISTING T-MOBILE EXISTING T-MOBILE CABLE BRIDGE x FIBER CABINET PROPOSED T MOBNE EXISTING T-MOBILE HYBRID CABLE TO x UTILITY H-FRAME FOLLOW EXISTING CABLE ROUTE vyP. OF 2PRO . EXISTING T-MOBILE LENGTH 215'1/65M:t) TELCO CABINET EXISTING T-MOBILE x 1OOA PPC TO BE REMOVED x -4' t. C m x - - EXISTING CABLE--r-- BRIDGE (TYP.) x- x- x- x- x- x x EXISTING x BUILDING I ❑ s' ,�st� 1 I PROPOSED EQUIPMENT PLAN PROPOSED 200A T-MOBILE METER EXISTING T-MOBILE FIBER CABINET EXISTING T-MOBILE UTILITY H-FRAME EXISTING T-MOBILE TELCO CABINET PROPOSED T—MOBILE Cs SERVICE LIGHT PROPOSED T-MOBILE 20GA PPC PROPOSED T- MOB ILE BATTERY CABINET 1 (E=SSON B180 CB PROPOSED T-MOBILE SITE SUPPORT CABINET (ERICSSON 6160)e C6 EXISTING BUILDING �r REV DATE DESCRIPTION A 4/6/21 PRELIMINARY REVISED B 4/9/21 C 4/16/21 REVISED 0 5/7/21 FOR PERMIT APX PROJECT NO.: 21-0270.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. A a ENGINEERING 14471 MIRAMAR PARKWAY, SURE 202 MIRAMAR, FL 33027 (954) 744-1538 CERTIFICATE OF AUTHORIZATION 31948 —Mobile Mobile •° I THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY EUEZER DIAZ, PE (#85219) ON MAY 7th, 2021 USING A DIGITAL SIGNATURE IN ACCORDANCE WITH FAC. 61G15-23.004, WITH A DIGITAL CERTIFICATE ISSUED BY ENTRUST, INC. PLEASE REFERENCE THE COVER PAGE TO VIEW THE SIGNATURE AND VERIFY ITS PROPERTIES. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES A2P0045B MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 EQUIPMENT PLANS SHEET NUMBER C2 PROPOSED T—MOBILE BATTERY CABINET (ERICSSON B180) -PROPOSED T—MOBILE AREA UGHT(UGHT—UP /LG—ALV2-15OW-27V-40K) PROPOSED LIGHT MIST '- STD. PIPE BY PROPOSED T—MOBILE 6'—O' LONG) SFE SUPPORT CABINET (ERI(SSON 8160) —PROPOSED U%fr MAST f (STTEPRO1 JACP10K) 10'-0. I OYP. OF 2) (TO GRADE) o Z �I EXISTING POST PROPOSED i1'/ — HILTI KWIK BOLT 3 EXISTING T—MOBILE CONCRETE EQUIPMENT PAD e SSC/BATTERY CABINET CONNECTION DETAIL NTS 1 WORK LIGHT DETAIL NTS 2 (NOT USED) 3 (NOT USED) 4 (NOT USED) 15 (NOT USED) 6 REV DATE DESCRIPTION A 4/6/21 PRELIMINARY B 4/9/21 REVISED C 4/16/21 REVISED 0 5/7/21 FOR PERMIT I APX PROJECT NO.: 21-0 770.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. apx _� E N G I N E E R I N G G R 0 U P 14471 MIRAMAR PARKWAY, SURE 202 MIRAMAR, FL 33027 (954) 744-1538 CERTIFICATE OF AUTHORIZATION 31948 F ° -Mobile Mobile _. THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY EU EZER DIAZ, PE (#85219) ON MAY 7th, 2021 USING A DIGITAL SIGNATURE IN ACCORDANCE WITH F.A-C. 61G15-23.004, WITH A DIGITAL CERTIFICATE ISSUED BY ENTRUST, INC. PLEASE REFERENCE THE COVER PAGE TO VIEW THE SIGNATURE AND VERIFY ITS PROPERTIES. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES A2P0045B MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 SHEET NAME DETAILS SHEET NUMBER C6 A - GENERAL Al. ALL ELECTRICAL WORK SHALL CONFORM TO THE NATIONAL ELECTRICAL CODE (EDITION ADOPTED BY LOCAL JURISDICTION) AND APPLICABLE LOCAL CODES. A2. GROUNDING SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE. A3. ALL ELECTRICAL EQUIPMENT AND ACCESSORIES SHALL BE U.L. APPROVED OR LISTED. A4. ALL POWER WIRING SHALL BE STRANDED COPPER, TYPE THHN/IHHW AND 90 DEGREES C RATED. A5. ALL POWER WIRING SHALL BE INSTALLED IN GALVANIZED RIGID STEEL CONDUIT, PVC, OR FLEXIBLE LIQUIDTIGHT CONDUIT, AS INDICATED. A5. CONTRACTOR SHALL OBTAIN ALL PERMITS, PAY PERMIT FEES, AND SCHEDULE INSPECTIONS. A7. CONTRACTOR SHALL APPLY FOR ELECTRICAL SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS, SERVICE ROUTING, AND METER SOCKET TYPE WITH LOCAL POWER COMPANY. A8. CONTRACTOR SHALL APPLY FOR TELEPHONE SERVICE AS SOON AS POSSIBLE AND COORDINATE REQUIREMENTS AND SERVICE ROUTING WITH TELEPHONE COMPANY. A9. PROVIDE ALL LABOR AND MATERIAL DESCRIBED ON THIS DRAWING, AND ALL ITEMS INCIDENTAL TO COMPLETING AND PRESENTING THIS PROJECT AS FULLY OPERATIONAL. A10. WHERE LONG POWER CABLE RUNS PREVAIL, CONTRACTOR SHALL CALCULATE THE VOLTAGE DROP AND SIZE WIRES AND CONDUIT ACCORDINGLY. A11. WHERE TRANSFORMER IS REQUIRED FOR ELECTRICAL SERVICE, TRANSFORMER SECONDARY SHALL BE GROUNDED PER N.E.C., ARTICLE 250-26. Al2. ALL ELECTRICAL DEVICES EXPOSED TO WEATHER SHALL BE OF RAINPROOF CONSTRUC TION AND SHALL REQUIRE WATER TIGHT Q G CONDUIT HUBS. A13. RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANGES, SUBSTITUTIONS BETWEEN WORK AS SPECIFIED AND INSTALLED. RECORD CHANGES ON A CLEAN SET OF CONTRACT DOCUMENTS WHICH SHALL BE TURNED OVER TO THE CONSTRUCTION MANAGER UPON COMPLETION OF THE PROJECT A14. GUARANTEE/WARRANTY: GUARANTEE INSTALLATION TO BE FREE OF DEFECTS, SHORTS, GROUNDS, ETC., FOR A PERIOD OF ONE YEAR. FURNISH WARRANTY SO THE DEFECTIVE MATERIAL AND/OR WORKMANSHIP WILL BE REPAIRED/REPLACED IMMEDIATELY UPON NOTIFICATION AT NO COST TO THE OWNER FOR PERIOD OF WARRANTY. A15. ALL TIE WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. A16. ELECTRICAL METALLIC TUBING (EMT) OR RIGID NONMETALLIC CONDUIT (I.E., RIGID PVC SCHEDULE 40, OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. A17. UQUID-TIGHT FLEXIBLE METALLIC CONDUIT (LIQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS, WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. A18. WIREWAYS SHALL BE EPDXY -COATED (GRAY) AND INCLUDE A HINGED COVER, DESIGNED TO SWING OPEN DOWNWARD; SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. A19. EQUIPMENT CABINETS, TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL, SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. A20. METAL RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED, OR NON -CORRODING; SHALL MEET OR EXCEED UL514A AND NEMA OS 1; AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. A21.NONMETALLIC RECEPTACLE, SWITCH, AND DEVICE BOXES SHALL MEET OR EXCEED NEMA OS 2; AND RATED NEMA 1 (OR BETTER) INDOORS, OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. B - POWER CABLE AND SERVICE 81. CONTRACTOR SHALL PROVIDE CONDUIT AND WIRING TO BTS AND VERIFY EXACT CONDUIT ROUTING. RACEWAY SYSTEM MATERIALS AND DEVICES FURNISHED SHALL BE IN ACCORDANCE WITH APPLICABLE STANDARDS OF ANSI, NEMA, AND UL. RACEWAY SYSTEM COMPONENTS SHALL BE INSTALLED IN ACCORDANCE WITH APPLICABLE REQUIREMENTS OF THE N.E.C. B2. CONTRACTOR SHALL SEAL AROUND ALL CONDUIT PENETRATIONS THROUGH WALLS, FLOORS AND ROOFS TO PREVENT MOISTURE PENETRATION OR VERMIN INFESTATION. 83. CONDUCTORS RUNNING ALONG HORIZONTAL SURFACES (ROOF TOP OR SLAB) SHALL BE INSTALLED IN RIGID CONDUIT SUPPORTED ON SLEEPERS. 84. ALL VERTICAL RUNS OF POWER CABLE EXCEEDING 80 FEET IN LENGTH SHALL BE SUPPORTED PER N.E.C. ARTICLE 300 USING KELLEMS GRIPS OR ACCEPTABLE EQUAL CABLE SUPPORT SYSTEM. B5. WHERE A SEPARATE ELECTRICAL SERVICE DROP IS ADDED, CONTRACTOR SHALL INSTALL PERMANENT SERVICE DISCONNECT OR GROUPING THEREOF, DENOTING ALL OTHER SERVICE ENTRANCES, LOCATION OF EACH AND THE AREAS SERVED BY EACH. 86. WHERE ELECTRICAL POWER IS TO BE SUB -FED FROM AN EXISTING DISTRIBUTION SYSTEM, THE FOLLOWING SHALL APPLY: A) CONTRACTOR SHALL PERFORM LOAD TESTING TO DETERMINE MAXIMUM FEEDER DEMAND PER N.E.C. ARTICLE 220-87. B) CONTRACTOR SHALL VERIFY WHETHER EXISTING FEEDER CAPACITY EXCEEDS VALUE CALCULATED PER N.E.C. ARTICLE 220-87. C) EACH BRANCH CIRCUIT PROTECTIVE DEVICE SHALL HAVE SAME INTERRUPTING RATING AS EQUIPMENT SUPPLYING IT. D) PREFERRED MEANS OF SUPPLY SHALL BE A BRANCH CIRCUIT PROTECTIVE DEVICE LOCATED IN EXISTING PANEL E) IF A BRANCH CIRCUIT PROTECTIVE DEVICE CANNOT BE OBTAINED OR SPACE IS NOT AVAILABLE, A BRANCH CIRCUIT MAY BE TAPPED FROM EXISTING FEEDER CONDUCTORS USING AN INSTALLED 2-POLE FUSED DISCONNECT AND METER BASE PER N.E.C. ARTICLE 240-21 WITH TEN FOOT (10) MAXIMUM TAP CONDUCTORS. FUSED DISCONNECT SHALL BE LISTED SAME OR BETTER INTERRUPTING RATING AS EXISTING SOURCE OF SUPPLY. C - IDENTIFICATION Cl. LOCATE NAMEPLATE, MARKING, OR OTHER IDENTIFICATION MEANS ON OUTSIDE EQUIPMENT OR BOX FRONT COVERS. C2. PROVIDE NAMEPLATE ENGRAVED WITH EQUIPMENT DESIGNATION FOR EACH SAFETY SWITCH AND ALL OTHER ELECTRICAL CABINETS, ETC. C3. DURING TRENCH BACK -FILLING FOR EACH UNDERGROUND ELECTRICAL, TELEPHONE, SIGNAL AND COMMUNICATIONS LINE, PROVIDE A CONTINUOUS UNDERGROUND WARNING TAPE TWELVE INCHES BELOW FINISHED GRADE. A - GENERAL Al. INSTALLATION OF GROUNDING SYSTEM SHALL COMPLY WITH ARTICLE 250 OF THE NATIONAL ELECTRIC CODE AND WITH ALL BUILDING CODES OF AUTHORITIES HAVING JURISDICTION. A2. GROUNDING CONDUCTORS SHALL BE #2 AWG TINNED SOLID BARE COPPER BELOW AND ABOVE GRADE, UNLESS OTHERWISE NOTED AND SHALL BE ROUTED IN A DOWNWARD PATH TOWARDS GROUND BARS_ A3. GROUNDING CONDUCTORS SHALL BE KEPT AS SHORT AND DIRECT AS POSSIBLE WITH MINIMUM BEND RADIUS OF 12 INCHES. A4. ALL BELOW GRADE CONNECTIONS SHALL BE CADWELD TYPE CONNECTIONS AND ALL CONNECTIONS TO EQUIPMENT AND GROUND BARS SHALL BE 2-HOLE BRONZE COMPRESSION CONNECTORS UNLESS OTHERWISE NOTED. A5. GROUNDING CONDUCTORS SHALL BE BONDED TO CABLE SUPPORTS, ANTENNA FRAMES, AND ANY SUPPORT FRAMES OR RACKS USING EXOTHERMIC WELDS OR MECHANICAL CONNECTIONS. AS. CONTRACTOR SHALL PROVIDE LOCK WASHERS FOR ALL MECHANICAL CONNECTIONS FOR GROUND CONDUCTORS, STAINLESS STEEL HARDWARE SHALL BE USED THROUGHOUT. A7. GROUNDING CONDUCTORS EMBEDDED IN CONCRETE OR PENETRATING WALLS AND FLOORS SHALL BE ENCASED IN PVC CONDUIT. NO METALLIC CONDUIT SHALL BE USED FOR GROUNDING CONDUCTORS UNLESS REQUIRED BY LOCAL CODES OR OTHERWISE INDICATED ON DRAWINGS. CONTRACTOR SHALL SEAL AROUND ALL CONDUIT PENETRATIONS TO PREVENT MOISTURE PENETRATION AND VERMIN INFESTATION. A8. CONTRACTOR SHALL VERIFY EXACT CONDUIT ROUTING FOR GROUNDING CONDUCTORS WHERE APPLICABLE. A9. DOUBLING OR STACKING OF ANY GROUNDING CONNECTIONS IS NOT ACCEPTABLE. B - PREPARATION B1. SURFACES: ALL CONNECTIONS SHALL BE MADE TO BARE METAL. ALL PAINTED SURFACES SHALL BE FIELD INSPECTED TO ENSURE PROPER CONTACT. ALL GALVANIZED SURFACES ON WHICH GALVANIZING HAS BEEN REMOVED BY CUTTING, DRILLING, OR ANY OTHER OPERATION SHALL BE RE -GALVANIZED IN ACCORDANCE WITH ASTM A780 USING "ZINC RICH" COATING AS MANUFACTURED BY ZRC CHEMICAL PRODUCTS COMPANY (LOCATED IN QUINCY, MASSACHUSETTS), OR ACCEPTABLE EQUAL NO WASHERS ARE ALLOWED BETWEEN ITEMS BEING GROUNDED. ALL CONNECTIONS ARE TO HAVE A NON -OXIDIZING AGENT ("COPPER SHIELD") APPLIED PRIOR TO INSTALLATION. 82. GROUND BAR: ALL COPPER GROUND OARS SHALL BE CLEANED, POLISHED AND A NON -OXIDIZING AGENT ("COPPER SHIELD") APPLIED. NO FINGER PRINTS OR DISCOLORED COPPER SHALL BE PERMITTED. T-MOBILE GROUNDING REQUIREMENTS T1. COAX CABLE OUTER CONDUCTORS (SHIELDS) SHALL BE GROUNDED USING COAX GROUNDING KITS AT A MINIMUM OF TWO POINTS, INCLUDING AT ANTENNA AND AT MASTER GROUND BAR. THE COAXIAL CABLE SHALL NOT EXCEED 100 FEET BETWEEN GROUNDING KITS. T2. COAX CABLE ENTERING A BUILDING SHALL BE GROUNDED WITH COAX GROUNDING KITS TO AN INSULATED COAX GROUND BAR WHICH SHALL BE INSTALLED ON THE OUTSIDE FACE OF THE BUILDING, BELOW THE CABLE ENTRY PORTS. T3. WHEN COAX CABLES ENTER A BUILDING FROM A TOWER, THE COAX GROUND BAR AT THE BUILDING SHALL BE CONNECTED TO THE EXTERNAL GROUND RING USING #2 AWG BARE TINNED SOLID COPPER ISOLATED IN PVC CONDUIT. REV DATE DESCRIPTION A 4/6/21 PRELIMINARY B 4/9/21 REVISED C 4/16/21 REVISED 0 5/7/21 FOR PERMIT APX PROJECT NO.: 21-0270.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. ap =X E N G I N E E R I N G G R O U P 14471 MIRAMAR PARKWAY, SURE 202 MIRAMAR, FL 33D27 (954) 744-153B CERTIFICATE OF AUTHORIZATION 31948 T i = Mobile THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY EUEZER DIAZ, PE (#85219) ON MAY 7th, 2021 USING A DIGITAL SIGNATURE IN ACCORDANCE WITH F.A.C. 611315-23.004, WITH A DIGITAL CERTIFICATE ISSUED BY ENTRUST, INC. PLEASE REFERENCE THE COVER PAGE TO VIEW THE SIGNATURE AND VERIFY ITS PROPERTIES. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES A2P0045B MICROWAVE SERVICE COMPANY 6159 N US-1 FORT PIERCE, FL 34951 SHEET NAME ELECTRICAL AND GROUNDING NOTES ELECTRICAL NOTES 11 I GROUNDING NOTES 1 2 J E1 REV DATE DESCRIPTION A 4/6/21 PRELIMINARY B 4/9/21 REVISED C 4/16/21 REVISED 0 5/7/21 1 FOR PERMIT APX PROJECT NO.: 21-0270.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. ap r--x ENG I N E E R I N G GROUP 14471 MIRAMAR PARKWAY, SURE 202 MIRAMAR, FL 33027 (954) 744-1538 CERTIFICATE OF AUTHORIZATION 31949 T E : Mobile •e THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ELIEZER DIAZ, PE (#85219) ON MAY 7th, 2021 USING A DIGITAL SIGNATURE IN ACCORDANCE WITH F.A.C. 611315-23.004, WITH A DIGITAL CERTIFICATE ISSUED BY ENTRUST, INC. PLEASE REFERENCE THE COVER PAGE TO VIEW THE SIGNATURE AND VERIFY ITS PROPERTIES. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES A2P0045B MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 SHEET NAME UTILITY ROUTING PLAN SHEET NUMBE32 E2 PROPOSED 2*0 CONDUIT FOR POWER (APPROX 100't IN LENGTH) (TYP. OF 2) LIGP -j , E2 PROPOSED Zro CONDUIT FOR POWER (SEE NOTES) I. x f x :E x NOTES: 1 i. PROPOSED CONDUIT ROUTING IS SCHEMATIC ONLY, CONTRACTOR SHALL DETERMINE SUITABLE ROUTING IN THE FIELD. 1 2. TERMINATION OF NEW CONDUITS AT CABINETS SHALL BE COORDINATED WITH T-40BILE FIELD MANAGER. 3. PROPOSED CONDUIT SHALL1"BE GALVANIZED RIGID STEEL APART FROM PORTION ENTIiRING EQUIPMENT CABINET, WHICH SHALL BE FLEXIBLE LIQUIDxTIGHT CONDUIT. 4. ALL CONDUIT TO BE ROUT�D DIRECTLY OFF PAD AND RUN UNDERGROUND OR ATTACHED TO SIDE OF PAD. PROPOSED 2'/ CONDUIT FOR POWER (SEE NOTES) PROPOSED T-MOBILE 2DOA DISCONNECT PROPOSED T-MOBILE 200A PPC PROPOSED 2'0 CONDUIT FOR POWER (SEE NOTES) PROPOSED T-MOBILE 200A METER PROPOSED 2'0 CONDUIT FOR POWER EXISTING T-MOBILE FIBER CABINET PROPOSED Z'O CONDUIT FOR TELCO/MV (SEE NOTES) - PROPOSED T-MOBILE SERVICE LIGHT - PROPOSED )1'0 CONDUIT FOR POWER (SEE NOTES) PROPOSED 2X'O CONDUIT FOR BATTERY CABLE & AUX POWER (SEE NOTES) — PROPOSED T-MOBILE BATTERY CABINET (ERI(SSON B160) PROPOSED ZVO CONDUIT FOR ALARM & TEMPERATURE SENSOR (SEE NOTES) PROPOSED T-MOBILE SITE SUPPORT CABINET (ERICSSON 6160) REV DATE DESCRIPTION A 4/6/21 PRELIMINARY B 4/9/21 REVISED C 4/16/21 REVISED 0 5/7/21 FOR PERMIT APX PROJECT NO.: 21-0270.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. A ax A ENGINEERING G ROU P 14471 MIRAMAR PARKWAY, SURE 202 MIRAMAR. FL 33027 (954) 744-1538 CERTIFICATE OF AUTHORIZATION 31948 T -Mobile THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY EUEZER DIAZ, PE (#85219) ON MAY 7th, 2021 USING A DIGITAL SIGNATURE IN ACCORDANCE WITH F.A.C. 61G15-23.004, WITH A DIGITAL CERTIFICATE ISSUED BY ENTRUST, INC. PLEASE REFERENCE THE COVER PAGE TO VIEW THE SIGNATURE AND VERIFY ITS PROPERTIES. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES A2P0045B MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 SHEET NAME UTILITY ROUTING PLAN SHEET NUMBER UTILITY ROUTING PLAN E3 c3cwi� �I r FAULT CURRENT CALCULATIONS AVAILABLE FAULT CURRENT AT UTILITY TRANSFORMER BASED ON FPUA AFC LETTER DATED APRIL 23, 2021: 8,311A F = (2)(4)(8.311) = 0.198 (13.923)(240) M = 1 = 0.834 1 +0.198 I = (8,311)(0.834) = 6,937A AFC PT 1 = 6,937A PROPOSED 303/0, 1#GG - 2-C PROPOSED 200A, 120/24OV, 10 HEAVY DUTY FUSIBLE DISCONNECT W/ 65kAIC CLASS J CURRENT LIMITING 200A1 FUSES (SEE NOTE 1) AFC PT 1 - 6,937A PROPOSED 200A RATED METER FROM SOURCE PROPOSED 3#3/0 — Z'C PROPOSED 1213-3/4-C TO EXISTING BURIED GROUND RING EXISTING GENERATOR W/ INTEGRATED TRANSFER SWITCH (SEE NOTE 3) NOTES: 1. BOND NEUTRAL TO GROUND IN DISCONNECT PROPOSED 3#3/0, 1#W — 2-C 200A PRIMARY & SECONDARY MAIN BREAKER W/ WALKING BEAM INTERLOCK 200A. 120/240V 1/ 2. PROVIDE PERMANENT SIGN AT T-MOBILE'S 200A SERVICE DISCONNECT: "20kW ON -SITE OPTIONAL STANDBY GENERATOR LOCATED SOUTH OF LOAD CENTER WITH 24 COMPOUND" BREAKER POSITIONS 3. FIELD VERIFY IF EXISTING GENERATOR INTEGRATED ATS IS RATED FOR 200A TO BE REUSED WITH NEW 200A INCOMING SERVICE. NOTIFY FOR IF PROPOSED POWER 200A INTEGRATED ATS IS RATED FOR LESS THAN 200A. PROTECTION CABINET TO REPLACE 4. PROVIDE FIELD OR FACTORY MARKED ARC FLASH WARNING LABEL FOR NEW ELECTRICAL EQUIPMENT THAT ARE LIKELY TO REQUIRE EXAMINATION, IXisnN' 200A PPC ADJUSTMENT, SERVICING, OR MAINTENANCE WHILE ENERGIZED PER NEC 110.16. 5. PROPOSED 200A FOUR -POSITION CIRCUIT BREAKER; SQUARE D #Q02200. PROPOSED AC ONE -LINE DIAGRAM NTS 1 PANEL I-MOBILL LOCATION: H-FRAME PANEL RAI IN6 200 AMPS PHASE 1 l20/240 VOLTS WIRE 3 _ MAIN LUG ONLY AIC RATING: 1OKA CKi NO. DESCRIPTION K AM WIRE GND COND COND GND WIRE AMP KVA DESCRIPTION CKT NO. B B 1 SURGE SUPPRESSOR 0 60/2 * * 15/1 0.18 - GFCI 2 3 - 0 1/2" #12 #12 20/1 - 0.15 SERVICE LIGHT 4 5 SITE SUPPORT CABINET (**) 13.7 - 200/2 #3/0 #6 2 1 /2" SPACE 6 9 SPACE 8 - 13.7 _ SPACE p 11 _ SPACE 12 13 SPACE - - SPACE 14 15 SPACE - - SPACE 16 13 SPACE - - SPACE 18 19 SPACE - - SPACE 20 21 SPACE - - SPACE 22 23 SPACE - SPACE 24 SUB TOTAL KVA (CONT) 0 0 0 0 SUB TOTAL KVA (CONY) SUB TOTAL KVA(NON-CONT) 13.7 13.7 0.18 0.15 SUBTOTAL KVA (NON-CONT) TOTAL KVA NON-CONT+ 125% CONT. 27.6 (***) 1149 TOTAL AMPS F'Kt VVIKtU AI t-AU I UKY ** PROPOSED 200AFOUR POSITION CIRCUIT BREAKER, SQUARE D #Q02200. *** T-MOBILE SITE SUPPORT CABINET HAS POWER MONITORING AND LOAD SHEDDING CAPACITY TO MAINTAIN OUTPUT LOAD BELOW 20kW DURING OPERATION OF 20kW EMERGENCY GENERATOR REV DATE DESCRIPTION A 4/6J21 PRELIMINARY B 4J9/21 REVISED C 4/16/21 REVISED 0 5/7/21 FOR PERMIT I I APX PROJECT NO.: 21-0270.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. ap�. E N G I N E E R I N G G R O U P 14471 MIRAMAR PARKWAY, SURE 202 MIRAMAR. FL 33027 (954) 744-1538 CERTIFICATE OF AUTHORIZATION 31948 T ­ Mobile _ THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY EUEZER DIAZ, PE (#85219) ON MAY 7th, 2021 USING A DIGITAL SIGNATURE IN ACCORDANCE WITH F.A.C. 61G15-23.004, WITH A DIGITAL CERTIFICATE ISSUED BY ENTRUST, INC. PLEASE REFERENCE THE COVER PAGE TO VIEW THE SIGNATURE AND VERIFY ITS PROPERTIES. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES A2P0045B MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 SHEET NAME ELECTRICAL DETAILS PROPOSED PANEL SCHEDULE 1 1311 E4 PROPOSED T-MOBILE ANTENNA (TYP.) PROPOSED /2 AWG SOLID BARE TINNED COPPER CONDUCTOR -- -,II J 2 EXISTING GROUND '�'•• BAR (TYP.) '':'•':;;;i� PROPOSED 18 AWG GREEN STRANDED COPPER CONDUCTOR (TYP.) PROPOSED J2 AWG SOLID DARE / TINNED COPPER CONDUCTOR (TYP.) / EXISTING BURIED GROUND RING PROPOSED 441 WELD CA all GROUNDING DIAGRAM (TYP. PROPOSED ANTENNA MOUNTING PIPE (TYP.) PROPOSED T—MOBWr RRU 4449 CM.) PROPOSED T—MOBILE RRU 4415 (TV.) PROPOSED T—MOBILE RRU 4424 (TYP.) PROPOSED T—MOBILE AIIyR6449 ANTENNA (p.) PROPOSED T—MOBILE SITE SUPPORT CABINET (ERI SSON 8160) PROPOSED T—MOBILE BATTERY CABINET (ERI SSON 8160) NTS EXISTING GROUND BAR SOLID BARED TINNED COPPER CONDUCTOR W/ THERMOWELD " WASHER SS BOLT 9 a V WASHER " SS LOCK WASHER 36" SS NUT TYPICAL GROUND BAR CONNECTION DETAIL NTSI2 FINISHED GRADE r W ¢ O 0 a0 Z mU Lu p z "a0 WARNING TAPE w= N w 200 PSI FLOWABLE FILL PVC CONDUITS 18" TRENCH OR AS REQUIRED BY L POWER/TELEPHONE COMPANY TRENCH DETAIL NTSI3 1 EXTERIOR GROUND— NO SLAG OR RING, #2 SOLID, DEFORMITIES ALLOWED BARE, THINNED COPPER GROUNDING CONDUCTOR EXOTHERMIC WELD (THERMOWELD OR EQUIVALENT) PARALLEL, NO T—WELDS ALLOWED. MINIMUM BENDING RADIUS 45 DEGREES, TYPICAL JUMPER, #2 SOLID, BARE, TINNED COPPER GROUNDING CONDUCTOR 1 j WELD CONNECTION DETAIL NTSI 4 REV DATE DESCRIPTION 4/6/21 PRELIMINARY r0A 4/9/21 REVISED 4/16/21 REVISED 5/7/21 FOR PERMIT APX PROJECT NO.: 21-0270.13 DRAWN BY: R. GARCIA CHECKED BY: M. ABBEY THIS DRAWING IS COPYRIGHTED AND IS THE SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WITHOUT THE WRITTEN PERMISSION OF THE OWNER. A ap A ENGIN EERING GROUP 14471 MIRAMAR PARKWAY, SUITE 2D2 MIRAMAR, FL 33D27 (954) 744-1538 CERTIFICATE OF AUTHORIZATION 31948 Mobile, THIS DOCUMENT HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY ELIEZER DIAZ, PE (#85219) ON MAY 7th, 2021 USING A DIGITAL SIGNATURE IN ACCORDANCE WITH FAC. 61G15-23.004, WITH A DIGITAL CERTIFICATE ISSUED BY ENTRUST, INC. PLEASE REFERENCE THE COVER PAGE TO VIEW THE SIGNATURE AND VERIFY ITS PROPERTIES. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES A2P0045B MICROWAVE SERVICE COMPANY 6189 N US-1 FORT PIERCE, FL 34951 SHEET NAME GROUNDING DETAILS SHEET NUMBER E5