HomeMy WebLinkAboutApproved Tower ModN N N N N W W W W W A A A A A
O N Am OD N A 0) C. N A a) OD
A O O O (O O O O O O mO N O O O O O O O O O O O O O O O
O v O G O O O O O O O f.110 CT O O O O O O O O O O O O O O O
W
OW �
x0
a
/ 4/+
a�CID
x
N
U
0
PO
ally signed
y MICHAEL
PHILLIPS
021.04.28
0:02 -04'00
RETROFIT SCHEDULE
SYMBOL
ELEVATION
MEMBER
EXISTING
PROPOSED
NOTES
TYPE
MEMBER
MEMBER
A
280't
GUY CABLE
-
-
TENSION EXISTING GUY CABLES TO 9% OF THEIR BREAKING STRENGTH.
192't TO
3/4ROD LID
SOLID
REINFORCE WITH ADDED SOLID
B
160't
DIAGONAL
ROD4'+
3/4"
ROD MEMBERSSREXITING
EFERENCDIAGONAL �AEMBEIL S3
SOUD ROD
C
176't
GUY CABLE
-
-
TENSION EXISTING GUY CABLES TO 9% OF THEIR BREAKING STRENGTH.
D
140't
GUY CABLE
-
-
TENSION EXISTING GUY CABLES TO 10% OF THEIR BREAKING STRENGTH.
E
480' TO 0'
TOWER MAST
-
_
ALIGN PLUMB AND TWIST OF TOWER IN ACCORDANCE WITH TIA-222-H,
ANNEX J.
TOWER ELEVATION G 2G 401
GRMHIC SCNE
REV
DATE
DESCRIPTION
0
4/28/21
FOR PERMIT
APX PROJECT NO.:
21-0270.13
DRAWN BY:
j
R. GARCIA
CHECKED BY:
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER.
A
ax
ENGI NEERING GROUP
14471 MIRAMAR PARKWAY, SUITE 202
MIRAMAR, FL 33027
(954) 744-1538
CERTIFICATE OF AUTHORIZATION 31948
I T • -Mobile
'ice` • t O R 10-.�.,r
'xrtlMSpff (�31T Gx 11E MIE MM'A1m.DYLExRr IRAiA nGrt.LSKKtiLPE
ca nuts mix roc. einisnaw. mm A urxru gamure issum er
;r. xc wwrm cross asnu oxcuuort ud: xu�caaasxsn sK>muo
-�iDT1E51W.lUE WS�BEV6iPmONNlY9ECRNX WxES
\ J
A2P0045B
MICROWAVE
SERVICE COMPANY
6189 N US-1
FORT PIERCE, FL 34951
SHEET NAME
TOWER
MODIFICATION
DETAILS
SHEET NUMBER
S1
DESIGNED APPURTENANCE LOADING
TYPE
ELEVATION
TYPE
ELEVATION
Flash Beacon Lighting
480
RRU 4424 (T-Mobile)
210
DS224-E
442
RRU 4424 (T-Mobile)
210
Standoff 2'
442
RRU 4415 (T-Mobile)
210
Dipole 10'
441.5
RRU 4415 (T-Mobile)
210
Standoff 1'
441.5
RRU 4415 (T-Mobile)
210
100A-4F-HW CALVARY CHAPEL
425
Sector Mount [SM502-3] ITMobile)210
Standoff l'
422.5
FFV4-65C-R3-V1(T-Mobile)
210
Dipole 10'
422.5
FFV4.65C-R3-VI (T-Mobile)
210
Standoff 5'
410
(3) SBNHH-i D856 (ATI)
208
Omni 10' by 3"
410
RRU 8843 B2/B66A (side) (ATI)
208
Standoff 1'
406
RRU 8843 B2/B66A (side) (ATI)
208
Dipole 10'
406
RRU 8843 B2/B66A (side) (ATI)
208
CL-FMRX (CALVARY CHAPEL)
375
RRU 4449 B5/B12 (side) (ATI)
208
8-Bay Dipole
373
RRU 4449 B5/B12 (side) (ATI)
208
Standoff 2'
373
RRU 4449 135/1312 (side) (ATI)
208
4-Bay Dipole
370.5
RRUS-32 (side) (ATI)
208
Standoff 2'
370.5
RRUS-32 (side) (ATI)
208
Omni 4' by 1.5" w/Pipe Mount
356
RRUS-32 (side) (ATI)
208
Standoff 5'
356
Raycap DC6A8-60-18-8F (ATT)
208
DB224-C
350
DC6A8-60-18-8C-EV (ATI)
208
Standoff 3'
350
DC6A8-60-18-8C-EV (ATI)
208
DB224-C
350
Sector Mount [SM410-3] (ATI)
208
Standoff 3'
350
(3) SBNHH-113856 (ATI)
208
Omni 12' by 3"
350
(3) SBNHH-1D856 (ATI)
208
Standoff 1'
350
DT465B (Sprint)
175
Omni 12' by 4"
337
APXVSPPIB-C-A20 (Sprint)
175
Standoff 1'
337
APXVSPPIB-C-A20 (Sprint)
175
R55247
317
APXVSPP18-C-A20(Sprint)
175
Standoff 2'
317
RRUS-82 (side) (Sprint)
175
(2) 6' Yagi
287.5
RRUS-82 (side) (Sprint)
175
Marker Light
242
RRUS-82 (side) (Sprint)
175
(2) X7CQAP665-V (Vedzon)
226
RRUS-11 (side) (Sprint)
175
AXP 19-60-2 (Verizon)
226
RRUS-11 (side) (Sprint)
175
AXP 19-60-2 (Verizon)
226
RRUS-11 (side) (Sprint)
175
AXP 19-60-2 (Verizon)
226
FFHS Filter (Sprint)
175
RRUS 32 (Verizon)
226
FFHS Filter (Sprint)
175
RRUS 32 (Verizon)
226
FFHS Filter (Sprint)
175
RRUS 32 (Verizon)
226
RRUS-31 (side) (Sprint)
175
(2) DBC-7CAP DIPlexer (Verizon)
226
RRUS-31 (side) (Sprint)
175
(2) DBC-7CAP DiPlexer (Verizon)
226
RRUS-31 (side) (Sprint)
175
(2) DBC-7CAP DiPlexer (Vedzon)
226
RRUS-1 1 (side) (Sprint)
175
RRFDC-3315-PF-48 (Vedzon)
226
RRUS-11 (side) (Sprint)
175
Sector Mount [SM502-3] erizon
226
RRUS-11 side) (Sprint)
175
(2) X7CQAP-665-V (Verizon)
226
800 SMR Filter (Sprint)
175
(2) X7CQAP665-V (Verizon)
226
800 SMR Filter (Sprint)
175
FFV4-65C-R3-V1(T-Mobile)
210
800 SMR Filter(Sprint)
175
AIR 6449 (T-Mobile)
210
Sector Mount [SM702-3] (Sprint)
175
AIR 6449 (T-Mobile)
210
DT465B (Sprint)
175
AIR 6449 (T-Mobile)
210
DT465B (Sprint)
175
RRU 4449 (T-Mobile)
210
3' Yagi
116.5
RRU 4449 (T-Mobile)
210
Standoff 2'
116.5
RRU 4449 (T-Mobile)
1210
GP6F-21A
104.5
RRU 4424 T-Mobile
1210
GP6F-21A
97.5
APPURTENANCE LOADING
1. TOWER RETROFIT DESIGN PERFORMED IN ACCORDANCE WITH THE FLORIDA BUILDING
CODE, 7th EDITION (2020), TO THE TIA-222-H STANDARD (FBC 3108.1) FOR THE
FOLLOWING CRITERIA:
A. V=160mph (ULTIMATE 3-SECOND GUST)
B. EXPOSURE "C"
C. RISK CATEGORY II
D. OPEN STRUCTURE
2. TOWER RETROFIT IS DESIGNED FOR THE LOADING INDICATED IN THE "APPURTENANCE
LOADING" TABLE INCLUDED IN THESE DRAWINGS. CONTRACTOR SHALL VERIFY EXISTING
TOWER LOADING TO INCLUDE THE QUANTITY AND TYPE OF EQUIPMENT AND COAX ON
THE TOWER. IF VARIES FROM THE DESIGN LOADING, CONTRACTOR SHALL NOTIFY
ENGINEER IMMEDIATELY.
3. CONTRACTOR SHALL VISIT SITE TO OBSERVE SITE CONDITIONS PRIOR TO BEGINNING
CONSTRUCTION.
4. CARE SHALL BE TAKEN TO MAINTAIN INTEGRITY OF EXISTING CONSTRUCTION. ENGINEER
SHALL BE IMMEDIATELY NOTIFIED OF ANY DAMAGE TO STRUCTURE DURING RETROFIT.
5. ALL RETROFIT MODIFICATIONS SHALL BE INCORPORATED PRIOR TO THE INSTALLATION OF
PROPOSED EQUIPMENT.
6. DIMENSIONS AND DETAILS SHOWN HAVE BEEN OBTAINED FROM LIMITED SURVEY DATA
AND/OR EXISTING DRAWINGS. ACTUAL SITE DIMENSIONS SHALL BE VERIFIED PRIOR TO
FABRICATION OF ANY MATERIAL.
7. CONTRACTOR SHALL SUBMIT TO ENGINEER NOTICE OF ANY INTENT TO DEVIATE FROM
PLANS AND DETAILS FOR APPROVAL PRIOR TO START OF ANY WORK.
8. CONTACT THE ENGINEER CONCERNING AND CHANGES OR MODIFICATIONS THAT MAY BE
REQUIRED DUE TO THE EXISTING CONDITIONS.
9. CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SITE SAFETY, PROTECTION OF PUBLIC,
AND TEMPORARY TOWER BRACING AS NECESSARY DURING RETROFIT INSTALLATION.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR LOCATING, PROTECTING, AND RELOCATING, AS
REQUIRED, ALL SERVICE AND UTILITY LINES IN THE VICINITY OF THE WORKSITE.
11. CONTRACTOR SHALL BE RESPONSIBLE FOR MEANS AND METHODS TO BE USED FOR
COMPLETING MODIFICATIONS.
12. DO NOT REMOVE ANY MATERIAL FROM THE TOWER DURING WINDS OF 15 MPH OR
GREATER.
13. PROPOSED TOWER MEMBERS AND MODIFIED EXISTING TOWER MEMBERS SHALL BE
PAINTED TO MATCH THE EXISTING TOWER MEMBERS THAT REMAIN UNMODIFIED AT THEIR
SAME ELEVATION.
RETROFIT NOTES
1. ALL PROPOSED RODS SHALL BE ASTM A572-50 MATERIAL AND GALVANIZED IN
ACCORDANCE WITH ASTM 123 AND ASTM 153 STANDARDS.
2. ALL PROPOSED PIPE MEMBERS SHALL HAVE A MINIMUM YIELD STRENGTH OF 50 ksi
AND BE GALVANIZED IN ACCORDANCE WITH ASTM 123 AND ASTM 153 STANDARDS.
3. ALL RETROFIT BOLTS SHALL BE ASTM A49OX WITH DACROMET CORROSION RESISTANT
FINISH, U.N.O.
4. ALL BOLTS SHALL BE TIGHTENED TO A "SNUG TIGHT" CONDITIONS AS DEFINED BY AISC.
5. ALL WELDS SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES, UNLESS NOTED
OTHERWISE.
6. ALL STEEL ABRASIONS, FIELD CUTS, AND FIELD WELDS SHALL BE COATED WITH TWO
LAYERS OF ZINK-RICH PAINT, CONNECT -IT WIRELESS #BZ01 OR APPROVED EQUAL.
11 GENERAL NOTES
COMPONENT
REACTION
MAST AXIAL
369 KIPS
GUY UPLIFT
164 KIPS
GUY SHEAR
176 KIPS
21 TOWER REACTIONS (FACTORED)
4 I (NOT USED)
3
REV
DATE
DESCRIPTION
0
4/28/21
FOR PERMIT
APX PROJECT NO.:
21-0270.13
DRAWN BY:
R. GARCIA
CHECKED BY:
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER. 10
A
ax
ENGINEERING GROUP
14471 MIRAMAR PARKWAY, SUITE 202
MIRAMAR, FL 33027
(954) 744-1538
CERTIFICATE OF AUTHORIZATION 31948
T • -Mobile
THIS DOCUMENT HAS BEEN
ELECTRONICALLY SIGNED AND
SEALED BY MICHAEL A. PHILLIPS,
PE (#68312) ON 4/28/21
USING A DIGITAL SIGNATURE IN
ACCORDANCE WITH F.A.C.
61G15-23.004, WITH A DIGITAL
CERTIFICATE ISSUED BY ENTRUST,
INC. PLEASE REFERENCE SHEET
T1 TO VIEW THE SIGNATURE AND
VERIFY ITS PROPERTIES.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT CONSIDERED
SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
A2P0045B
MICROWAVE
SERVICE COMPANY
6189 N US-1
FORT PIERCE, FL 34951
SHEET NAME
TOWER
MODIFICATION
DETAILS
SHEET NUMBER
5 S2
2" FROM EXISTING
WELD (TYP.)
EXISTING TOWER LEG
(TYP.)
EXISTING HORIZONTAL
(TYP.)
NOTES:
1. IF EXISTING SOLID ROD MEMBERS ARE BENT, THEY WILL NEED STRAIGHTENING PRIOR TO
ATTACHMENT OF NEW MEMBERS. USE PROPER TOOLS & AVOID STRESSING OTHER TOWER
MEMBERS & WELDS OF BENT MEMBERS.
2. NEW SOLID ROD SHALL BE INSTALLED PARALLEL & STRAIGHT AGAINST SOLID ROD MEMBERS.
3. THE WIRE CLIP SIZE SHALL MATCH THE ROD SIZE, UNLESS NOTED OTHERWISE.
DIAGONAL BRACE RETROFIT
/N7EyWWIRE CUP
p
\,'r.)
NEW SOLID
ROD DIAGONAL
(TYP.)
EXISTING SOLID
ROD DIAGONAL
(TYP.)
NEW SOLID ROD SAME
SIZE AS EXISTING
EXISTING SOLID
NEW WIRE
SOLID ROD CONNECTION (PREFERRED) NTS 2
NEW SOLID ROD SAME
SIZE AS EXISTING
EXISTING SOLID ROD
NEW WIRE CUP
11 SOLID ROD CONNECTION (ALTERNATE)
REV
DATE
DESCRIPTION
0
4/28/21
FOR PERMIT
APX PROJECT NO.:
21-0270.13
DRAWN BY:
R. GARCIA
CHECKED BY:
M. ABBEY
THIS DRAWING IS COPYRIGHTED AND IS
THE SOLE PROPERTY OF THE OWNER. IT
IS PRODUCED SOLELY FOR USE BY THE
OWNER AND ITS AFFILIATES.
REPRODUCTION OR USE OF THIS DRAWING
AND/OR THE INFORMATION CONTAINED IN
IT IS FORBIDDEN WITHOUT THE WRITTEN
PERMISSION OF THE OWNER. 10
A
ax
ENGINEERING GROUP
14471 MIRAMAR PARKWAY, SUITE 202
MIRAMAR, FL 33027
(954) 744-1538
CERTIFICATE OF AUTHORIZATION 31948
T • -Mobile •°
THIS DOCUMENT HAS BEEN
ELECTRONICALLY SIGNED AND
SEALED BY MICHAEL A. PHILLIPS,
PE (#68312) ON 4/28/21
USING A DIGITAL SIGNATURE IN
ACCORDANCE WITH F.A.C.
61G15-23.004, WITH A DIGITAL
CERTIFICATE ISSUED BY ENTRUST,
INC. PLEASE REFERENCE SHEET
T1 TO VIEW THE SIGNATURE AND
VERIFY ITS PROPERTIES.
PRINTED COPIES OF THIS
DOCUMENT ARE NOT CONSIDERED
SIGNED AND SEALED AND THE
SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
A2P0045B
MICROWAVE
SERVICE COMPANY
6189 N US-1
FORT PIERCE, FL 34951
SHEET NAME
TOWER
MODIFICATION
DETAILS
SHEET NUMBER
3 S3