Loading...
HomeMy WebLinkAboutGENERAL INFORMATIONSection A (General Information) Master Permit No, Process No. Contractors Name: ONE CONSTRUCTION & ROOFING CONTRACTORS, INC License # CCC-1330623 JobAddress4812 MYRTLE DR PORT SAINT LUCIE FL 34982 ROOF CATEGORY ® Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ® Asphaltic Shingles ❑ Metal Panel/Shingles C]Wood Shingles/Shakes 0 Prescriptive BUR-RAS 150 ROOF ROOF TYPE. C] New roof C) Repair © Maintenance ® Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 80 SQ. Ft Steep Sloped Roof Area (SF) 1807 SQ. FT. Total (SF)1887 SQ. Ft. Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. i E i 1 7 i f E i ! 3 3 3 1 1 i f { 3• ! I i 4 1� Ei�F2 ! I f t 7 f 1 [ NVP0 3 ` 3 t t r 1404) 24 r 3 t ! 18 f 3 4 i2 13 f, BAS 49 ( 1607 ) t10 6 _ 26 ST. LUCIE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: POLYGLASS USA Product Approval No.: FL#1654-R27 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': -36.1 Zone 1: -36.1 Zone 2: -47.7 Zone 3: -64.9 Max. Design Pressure, from the specific product approval system: Peel & Stick / SBS-SA Deck: Type: Plywood Gauge Thickness: 19/32 CDX Slope: 1/12 Anchor/Base Sheet & No. df Ply(s): N/A Anchor/Base Sheet Fastener/Bonding Material: N/A Insulation Base Layer: N/A Base Insultation Size and Thickness: N/A Base Insulation Fastener/Bonding Material: N/A Top Insulation Layer: N/A Top Insulation Size and Thickness: NIA Top Insulation Fastener/Bonding Material: N/A Base Sheet(s) & No. of Ply(s): (1) Base Sheet Fastener/Bonding Material: SELF -ADHERING Ply Sheet(s)' & No. of Ply(s): N/A Ply Sheet Fastener/Bonding Material: N/A Top Ply: (1) Top Ply Fastener/Bonding Material: SELF -ADHERING Surfacing: N/A Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows— @ ° oc Zone 1:_.._." oc @ Lap, # Rows ® woo Zone 2:_" oc @ Lap, # Rows @ " oc Zone 3:—" oc @ Lap, # Rows, @ "oc Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3 Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. . ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Tamko Building products Notice of Acceptance Number: FI # 18355-R6 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): :Zone 1:-38.1 Zone 2e: -50•2 Zone 2n: -50.2 Zone 2r: -49.6 Zone 3e: -50.2 Zone 3r: -50.2 7Type 19/32 CDX Plywood derlayment Tri-built /peel & stick Roof Slope: 5 :12ulation: N/A Fire Barrier: =N/A Ridge Ventilation? Fastener Type & Spacing: 1-1/4" x .120 Coil Nails / 6 nails pattern N/A Adhesive Type: N/A Type Cap Sheet: F N/A i Mean Roof Height: 12' Roof Covering: Shingle / Tamko —� Type & Size Drip 2" x 2" / Aluminum Edge: