HomeMy WebLinkAboutNEW WINDOW & DOOR SCHEDULEALL WIND LOAD CALCULATIONS ARE BASED ON FLORIDA BUILDING CODE -ITH EDITION (2020)
ASCE l-Iro
WIND VELOCITY=110 MPH
EXPOSURE C
MEAN ROOF HEIGHT --
SCOPE OF WORK:
ALL EX15TING WINDOWS 4 DOORS THAT ARE LABELED TO BE REPLACED WITH PGT IMPACT PRODUCTS
ALL IMPACT PRODUCTS TO BE INSTALLED AS PER PRODUCT APPROVAL.
NEW WINDOW AND DOOR &CHEDUL E
SYM
TYPE
SIZE
SQ. FT.
PRODUCT
APPROVAL
ACCEPTANCES
END
ZONE
WIND PRES.
WIND PRES.
APPROVED
REQUIRED
+
,4
HORIZONTAL ROLLER
41.25 x 49.25
16
NOA 20-040(oD4
5
65.0
65.0
36.1
41.2
B
HORIZONTAL ROLLER
52.5 x 31.25
14
NOA 20-040624
4
65.0
65.0
36.1
393
C
HORIZONTAL ROLLER
106 x 61.5
46
NOA 20-040624
5
51.3
513
33.8
42.1
D
HORIZONTAL ROLLER
64 x 61.5
21
NOA 20-040624
4
65.0
65.0
35.1
383
E
PICTURE WINDOW
34 x 61.5
15
NOA 20-0416.10
4
65.0
60.0
36.1
393
F
HORIZONTAL ROLLER
64 x 61.5
26
NOA 20-040624
5
65.0
65.0
35.1
45.2
G
HORIZONTAL ROLLER
11 x 61.5
30
NOA 20-040624
4
65.0
65.0
35.1
383
H
SINGLE HUNG
31 x 52.15
15
NOA 20-0401,11
4
65.0
65.0
36.1
393
I
SINGLE HUNG
31 x 52.15
15
NOA 20-0401,11
5
65.0
65.0
36.1
45.2
J
SINGLE HUNG
31 x 52.15
15
NOA 20-0401,11
4
65.0
80.0
36.1
393
K
SINGLE HUNG
31 x 52.15
15
NOA 20-0401,11
5
65.0
60.0
36.1
45.2
L
SINGLE HUNG
31 x 52.15
15
NOA 20-0401,11
5
65.0
60.0
36.1
45.2
M
HORIZONTAL ROLLER
4125 x 49.25
16
NOA 20-040624
5
65.0
65.0
36.1
45.2
I
SWING DOOR
33B x 19.15
IS
NOA 20-042101
4
15.0
15.0
36.1
45.2
2
SWING DOOR
32.5 x 19.15
10
NOA 20-042101
5
15.0
15.0
36.1
45.2
,4L5ERT'5 RESIDENCE
1000-1 5 INDIAN RIVER DR
FORT PIERCE, FLORIDA
LEGAL DESCRIPTION
29 36 41 S 62.5 FT OF THAT P,4RT OF FOL DESC f ARCEL LYG E OF R/W OF FEC RR:
BEG AT WATER*S EDGE OFIND RIV AT NE COR LOT I RUN SELYALONG WATER'S EDGE
2244 FT M/L TO 41-15ERT ERNST 5CH,4EF f ROf ERTY 45 IN DB 4,4 PGE 2-13 TH W ON N
LINE OF 5CH,4EF f ROf ERTY 2653.2 FT M/L TO W LINE OF E 1/2 OF NE 1/4 OF SEC 30,
TH N IroO3 FT M/L TO SEC LINE BETWEEN SECS 19 AND 30, TH E 1(B4-1 FT M/L TO
f=)OB-LESS RE)-