Loading...
HomeMy WebLinkAboutNOAMIAMI•MIAMI-DADE COUNTY PRODUCT CONTROL SECTION oDADE 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) T (786) 31Miami, F (786) 175-2474 BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE(NOA)www.miamidade.gov/economy PGT Industries, Inc. 1070 Technology Drive North Venice, FL 34275 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "FD-101" Aluminum Outswing French Doors w/wo Sidelites— L.M.I. APPROVAL DOCUMENT: Drawing No. 11005-1 Rev H, titled "Alum. French Door & Sidelites, Impact", sheets 1 through 15 of 15, dated 04/04/2012 and last revised on 04/20/20, prepared by PGT Industries, signed and sealed by Anthony Lynn Miller, P. E., bearing the Miami —Dade County Product Control Revision stamp with the Notice of Acceptance number and Expiration date by the Miami —Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitations: 1. Use of Tables 1 or 2 (sheet 2) requires full length reinforcements (item # 22) for OX, XO, XXO, OXX, OXO and OXXO configurations. The lower design pressure from table 1 or table 2 shall control. 2. Standalone X, XX and O configuration unit do not require, reinforcement (item #22). 3. Applicable Egress operable doors must comply with min clear width & height per FBC, to be reviewed by AHJ. 4. Ix or 2x buck to be properly secured to sustain imposed load and to be reviewed by AHJ. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and series and following statement: "Miami -Dade County Product Control Approved", noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #17-0504.01 and consists of this page 1 and evidence pages E-1, E-2 & E-3, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq L Chanda, P.E. NOA No. 20-0427.01 =MIAM=ECOUNTY Expiration Date: October 18, 2022 Approval Date: September 03, 2020 Page 1 PGT Industries, Inc. ANCE: EVID 1. Evidence submitted under previous approvals A. DRAWINGS in Manufacturer's die drawings and sections (Submitted under files # listed below) 2. Drawing No. 11005-1 Rev F, titled "Alum. French Door & Sidelites, Impact", sheets 1 through 10 of 10, dated 04/04/2012 and last revised on 09/08/16, prepared by PGT Industries, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. Test report on 1) Uniform Static Air Pressure Test, per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 Along with marked -up drawings and installation diagram of Aluminum Sliding Glass Doors (w/ TPS, Super, Cardinal & Duraseal Spacers), prepared by Fenestration Testing Laboratory, Inc., Test Reports No(s) FTL-8717, FTL-8970 and FTL-8968, dated 02/15/16, 06/07/16 and 06/20/16, all signed & sealed by Idalmis Ortega, P.E.(submitted under file #16-0629.17) 2. Test reports on: 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS 203-94 Along with marked —up drawings and installation diagram of fixed sidelite (0) w/ insulated laminated glass, prepared by Fenestration Testing Laboratory, Inc., Test Reports No(s) FTL--6864, dated 04/02/12, signed and sealed by Marlin D. Brinson, P. E. (Submitted under files #12-0516.02/#11- 1013.22) 3. Test report on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 Along with marked —up drawings and installation diagram of Aluminum outswing doors w/sidelites, prepared by Fenestration Testing Laboratory, Inc., Test Reports No FTL-5212, dated 05/05/2007, signed and sealed by Carlos S. Rionda, P. E. (Submitted under files # 12-516.02/#11-1013.22) Co CALCULATIONS (Submitted under file #15-0528.24) 1. Anchor verification calculations and structural analysis dated 05/22/15, complying with FBC- 214 (51h Edition), prepared by PGT, signed and sealed by Lynn Miller, P.E. 2. Glazing complies w/ ASTME-1300-02, 04 & -09. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). Ishaq I. Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0427.01 Expiration Date: October 18, 2022 Approval Date: September 03, 2020 E-1 PGT Industries, Inc. NOTICE OF ACCL:YrAl�lc E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 14-0916.10 issued to Kuraray America, Inc. (former E.I. DuPont DeNemours & Co., Inc.) for "Kuraray Butacite PVB Interlayer", expiring on 12/11/16. 2. Notice of Acceptance No. 124231.10 issued to Eastman Chemical Company (MA) former Solutia Inc. for their "Saflex Clear or colored interlayer", expiring on 05/21/16. F. STATEMENTS (Submitted under file #15-0528.24) 1. Statement letter of conformance to FBC 2014(5 h edition) and letter of no financial interest, prepared by PGT, dated 05/22/15, signed and sealed by Lynn Miller, P.E. 2. Lab compliance as part of the above referenced test report. G. OTHER 1. This NOA revises NOA #15-0528.24, expiring 10/18/17. 2. Test proposal # 16-0152 dated 03/09/16 approved by RER 3. Test proposals dated Jan 18, 2017 and 02/15/12 approved by Jaime D. Gascon, P.E. 2. Evidence submitted under previous approval A. DRAWINGS 1. Drawing No. 11005-1 Rev G, titled "Alum. French Door & Sidelites, Impact", sheets 1 through 15 of 15, dated 04/04/2012 and last revised on 09/17/17, prepared by PGT Industries, signed and sealed by Anthony Lynn Miller, P.E. B. TESTS 1. None. C. 1. Anchor verification calculations and structural analysis dated 08/01/17, complying with FBC- 2014 (5TH Edition) & 2017(6th Edition), prepared by PGT, signed and sealed by Lynn Miller, P.E. 2. Glazing complies w/ ASTME-1300-02, 04 & -09. D. 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS l . Notice of Acceptance No. 16-1117.01 issued to Kuraray America, Inc. (former E.I. DuPont DeNemours & Co., Inc.) for "Trosifol: Ultra clear, clear & color PVB glass interlayer" (former "Kuraray Butacite PVB Interlayer)", expiring on 07/08/19. 2. Notice of Acceptance No. 154201.11 issued to Eastman Chemical Company (MA) former Solutia Inc. for their "Saflex Clear or colored interlayer", expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance to FBC 2014(Sth edition), FBC 2017(6th edition) and letter of no financial interest, prepared by PGT, dated 08/01/17, signed and sealed by Lynn Miller, P.E. G. OTHER 1. This NOA revises &renews NOA 4416-0629.17, expiring 10/18/22. Ishaq L Chanda, P.E. Product Control Unit Supervisor NOA No. 20-0427.01 Expiration Date: October 18, 2022 Approval Date: September 03, 2020 E-2 PGT Industries, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 3. New Evidence submitted A. DRAWINGS L Drawing No. 11005-1 Rev H, titled "Alum. French Door & Sidelites, Impact", sheets 1 through 15 of 15, dated 04/04/2012 and last revised on 04/2020, prepared by PGT Industries, signed and sealed by Anthony Lynn Miller, P. E. B. TESTS 1. Test report on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per ASTM F588 and TAS 202-94 along with marked -up drawings and installation diagram of all PGT Industries, Inc. representative units listed below and tested to qualify Dowsil 791 and Dowsil 983 silicones, prepared by Fenestration Testing Laboratory, Inc., Test Reports No.: FTL-7897, PGT PW5520 PVC Fixed Window (unit 6 in proposal), dated 09/03/14 FTL-20-2107.1, PGT SGD780 Aluminum Sliding Glass Door (unit 7 in proposal) FTL-20-2107.2, PGT CA740 Alum. Outswing Casement Window (unit 8 in proposal) FTL-20-2107.3, PGT PW7620A Aluminum Fixed Window (unit 9 in proposal) and FTL-20-2107.4, PGT PW7620A Aluminum Fixed Window (unit 10 in proposal) dated 07/13/20, all signed and sealed by Idalmis Ortega, P.E. C. CALCULATIONS 1. Anchor verification calculations and structural analysis dated 04/15/20, complying with FBC- 2020 (711 Edition), prepared by PGT, signed and sealed by Lynn Miller, P.E. 2. Glazing complies w/ ASTME4300-02, -04 -09 & -16. D. QUALITY ASSURANCE 1. Miami Dade Department of Regulatory and Economic Resources (RER). E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 19-0305.02 issued to Kuraray America, Inc. (former E.I. DuPont DE Nemours & Co., Inc.) for "Trosifol: Ultra clear, clear & color PVB glass interlayer" (former "Kuraray Butacite PVB Interlayer)", expiring on 07/08/24. 2. Notice of Acceptance No. 154201.11 issued to Eastman Chemical Company (MA) former Solutia Inc. for their "Saflex Clear or colored interlayer", expiring on 05/21/21. F. STATEMENTS 1. Statement letter of conformance to FBC 2020 (7th edition), and letter of no financial interest, prepared by PGT, dated 04/15/20, signed and sealed by Lynn Miller, P.E. 2. Letter of lab compliance, part of the above test reports. G. OTHER 1. This NOA revises NOA #17-0504.01 and updates to FBC 2020 (7t" Edition), expiring 10/18/22. 2. RER Test proposals 4194155 dated 01/10/20 approved by Ishaq T rhnn�a P F I Lz isnaq i. t nanoa, r.E. Product Control Unit Supervisor NOA No. 20-0427.01 Expiration Date: October 18, 2022 Approval Date: September 03, 2020 E-3 SERIES 101 OUTSWING, IMPACT RESISTANT FRENCH DOOR AND SIDE LITE 1) GLAZING OPTIONS: SEE BELOW. 2) DESIGN PRESSURES: (SEE TABLES 1-4 ON SHEET 2. A. NEGATIVE DESIGN LOADS BASED ON TESTED PRESSURE AND GLASS TABLES ASTM E 1300. B. POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE AND GLASS TABLES ASTM E 1300. C. DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN, ASD. 3) CONFIGURATIONS: X, O, XX, XO, OX, XXO, OXX, OXO, AND OXXO. 4) ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. FOR ANCHORAGE REQUIREMENTS SEE SHEETS 8-11. MATERIALS, INCLUDING BUT NOT LIMITED TO STEEL SCREWS, THAT COME INTO CONTACT WITH OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FBC, CURRENT EDITION. 5) SHUTTERS ARE NOT REQUIRED. 6) SEALANTS: INSTALLATION SCREWS, FRAME AND PANEL CORNERS SEALED WITH CLEAR COLORED SEALANT. 7) REFERENCES: TEST REPORT FTL-4964, 5212 & 6864; ELCO ULTRACON, DEWALT ULTRACON+ & DEWALT/ELCO CRETEFLEX NOA'S 8) THIS PRODUCT HAS BEEN DESIGNED & TESTED TO COMPLY WITH THE REQUIREMENTS. OF THE FLORIDA BUILDING CODE, INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 9) DOOR SIZES MUST BE VERIFIED FOR COMPLIANCE WITH EGRESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE. APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY AUTHORITY HAVING JURISDICTION (AHJ). INSTRUCTIONS: 1) DETERMINE THE DESIGN PRESSURE, DP REQUIREMENT (LBS/FTZ) FOR THE OPENING USING THE ASCE-7 STANDARD. 2) ON SHEET 2, TABLES 1 & 2 REFER TO PRODUCTS THAT ARE REINFORCED. TABLES 3 & 4 REFER TO PRODUCTS THAT ARE UNREINFORCED. DETERMINE THE DESIGN PRESSURE OF YOUR PRODUCT USING THE APPROPRIATE SET OF TABLES. EXAMPLES ARE GIVEN ON SHEET 2. THIS DESIGN PRESSURE NEEDS TO BE HIGHER THAN THE OPENING'S REQUIRED DESIGN PRESSURE FROM STEP 1. 3) DETERMINE YOUR ANCHOR GROUP FROM TABLE A, THIS SHEET AND YOUR GLASS TYPES, (A - D), FROM THE GLAZING DETAILS ON THIS SHEET. 4) FROM SHEETS 7-13, FIND THE SHEET THAT PERTAINS TO YOUR PRODUCT AND DETERMINE THE ANCHOR QUANTITIES REQUIRED. 5) ANCHORS ARE TO BE INSTALLED USING THE LOCATION GUIDELINES GIVEN IN THE NOTES ON SHEETS 7-13. SHEET 14 & 15 SHOW INSTALLATION CROSS -SECTIONAL DETAILS. 3/8" NOM. GLASS STACK 3/16" HS GLASS — .090" PVB1 OR PVB2 INTERLAYER 1/8" AN OR HS GLASS — a EXTERIOR 3/8" LAMI NOM. GLASS TYPE A GLASS TYPE B TABLE A'. DESIGN PRESSURE RATING IMPACT RATING SEE TABLES 1 - 4 ON SHEET 2 RATED FOR LARGE & SMALL MISSILE IMPACT RESISTANCE. Min. Anchor Frame Min. Edge Embedment or Group Anchor Type Member Substrate Distance Metal Thickness All Concrete (min. 2.85 ksi) 1-3/4" 1-3/8" 114" Elco UltraCon® Jamb Hollow Block (ASTM C90) 1-3/4" 1-1/4" 1 All Concrete (min. 3 ksi) 1-3/4" 1-3/8" 1/4" DeWalt Ultra Con+® Jamb Hollow Block (ASTM C90) 1-314" 1-1/4" All Concrete (min. 3.35 ksi) 1 3/4" 1-3/4" 2 1/4" 410 Elco/DeWalt Jamb Hollow Block (ASTM C90) 1-314" 1-1/4" e Crett e Flex® All Southern Pine (SG = 0.55) V 1-3/8" All Southem Pine (SG = 0.55) 9/16" 1-3/8" #12 SMS (steel, 18-8 S.S. or All 6063-T5 Aluminum 3/8" 1/8" 3 410 S.S.) All Steel, A36 3/8" 0.060" All Steel Stud, A1003 Gr. 33 3/8" 0.0451" (18 Ga.) 1) ALL ANCHOR HEAD TYPES ARE APPLICABLE. 2) MIN. OF 3 THREADS BEYOND METAL SUBSTRATE. 3) METAL SUBSTRATE TO MEET MIN. STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. Material Min. Fy Min. F„ Steel Screw 92 ksi 120 ksi 18-8 Screw 60 ksi 95 ksi 410 Screw 90 ksi 110 ksi Elco UltraCon® 155 ksi 177 ksi 1/4" DeWalt UltraCon+® 148 ksi 164 ksi 410 SS Elco/Dewaft CreteFlex® 127.4 ksi 189.7 ksi 6063-T5 Aluminum 16 ksi 22 ksi A36 Steel 36 ksi 58 ksi Gr. 33 Steel Stud 33 ksi 45 ksi 3/16" HS GLASS 090" PVB1 OR PVB2 INTERLAYER 316" AN OR HS GLASS 1/2" GLASS BITE AN = ANNEALED HS = HEAT -STRENGTHENED TP = TEMPERED 7/16" NOM. GLASS STACK 1/2" GLASS BITE EXTERIOR 7/16" LAMI NOM. GLASS TYPE C GLASS TYPE D GENERAL NOTES ............ 1 GLAZING DETAILS .... ....... 1 DESIGN PRESSURES...... 2 VERT. SECTIONS.............3 HORIZ. SECTIONS........... 4 PARTS LIST ...................... 5 EXTRUSIONS ................... 6 ANCHOR QUANTITY........ 7-13 INSTALLATION ................. 14-15 CODES / STANDARDS USED: • 2020 FLORIDA BUILDING CODE (FBC), 7TH EDITION • 2017 FLORIDA BUILDING CODE (FBC), 6TH EDITION • ASTM E1300-09 • ANSI/AF&PA NDS-2018 FOR WOOD CONSTRUCTION • ALUMINUM DESIGN MANUAL, ADM-2015 • AISI S100-16 • AISC 360-16 13/16" NOM. GLASS STACK 1/8"HSG 1/4" AIR SPACE 3/16" TP GLASS — 3/16" HS GLASS .090" PVB1 OR PVB2 INTERLAYER 1/2" GLASS BITE 'a EXTERIOR 13/16" LAMI IG NOM. GLASS TYPE E PVB1 = .090" TROSIFOLO PVB BY KURARAY AMERICA, INC. PVB2 = .090" SAFLEX/KEEPSAFE MAXIMUM PVB BY EASTMAN CHEMICAL CO. as compkift with hthee MrIA, NNo 20' py 27•01 Astqgsucc �"It t '�+Iii�Rd H) UPDATED TO FBC 2020, REVISED ANCHOR TYPE TABLE. AK - 04/15/20 N Y = LU O nay o O 0 LO (7 N O 6 a}od O m cn o r O IL `- m = W 7 OD Cj W Xa "ON 0M0 W— l uMoip W C)rz_W J O a% r Z . , 0 LO r to C,6 U) J LL O IY 0 < ® rn p Q 3aa4s rn z v C/) o. Z (D z H W ❑ aloas Q J 0 Q Q � Z Isa.1jasl al}il •asap Nor LYNN Q. = No. 58705 p TATE F = \ /S BONAL 0\ A. LYNN MILLER, P.E. P.E.# 58705 NOTES FOR ALL CONFIGURATIONS: TABLE 1 DESIGN PRESSURES FOR DOORS, ALL GLASS TYPES REINFORCED DOOR TO SIDE LITE OR UNREINFORCED STAND-ALONE DOOR X FRAME WIDTH XX FRAME WIDTH FRAME HEIGHT 6'- 79 3/4" 70 - 83 3/4" 87 34' 91 3/4" 80 - 95 3/4" 3° 371/2" 60 713/4 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 75.0 -75.0 75.0 -75.0 TABLE 2: DESIGN PRESSURES FOR SIDE LITES REINFORCED DOOR TO SIDE LITE OR UNREINFORCED STAND-ALONE SIDE LITE GLASS TYPES FRAME WIDTH FRAME HEIGHT 68 - 79 3/4" 7° - 83 3/4" 87 3/4" 91 3/4" 80 - 95 3/4" 27 3/4" +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 A 361/8" +75.0 -75.0 +75.0 -75.0 +71.4 -71.4 +67.6 -67.6 +64.2 -64.2 36 3/4" +75.0 -75.0 +74.9 -74.9 +70.4 -70.4 66.6 -66.6 +63.1 -63.1 �B,C,DORE 36 3/4" +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 FOR MAX. SIZES OF COMBINED UNITS, SEE SHEETS 10-13. DOOR SIZES MUST BE VERIFIED FOR COMPLIANCE WITH EGRESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE. APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY AUTHORITY HAVING JURISDICTION (AHJ). EXAMPLE 1, (USING TABLES 1 & 2): XO WITH GLASS TYPE B, REINFORCED, 33-1/2" WIDE X 79-3/4" HIGH SINGLE DOOR WITH 18" X 79-3/4" SIDE LITE (SEE NOTE 8) DOOR DESIGN PRESSURE = +75 / -75 PSF SIDE LITE DESIGN PRESSURE _ +75 / -75 PSF OVERALL DESIGN PRESSURE _ +75 / -75 PSF EXAMPLE 3, (USING TABLES 3 & 4): OXO WITH GLASS TYPE C, UNREINFORCED, 30" WIDE X 87-3/4" HIGH SINGLE DOOR WITH (2) 26" X 87-3/4" SIDE LITES (SEE NOTE 8) DOOR DESIGN PRESSURE = +43.6 / -43.6 PSF SIDE LITE DESIGN PRESSURE = +47.2 / -47.2 PSF OVERALL DESIGN PRESSURE = +43.6 / -43.6 PSF EXAMPLE 5, (USING TABLE 1): X WITH GLASS TYPE A, 32" WIDE X 90" HIGH SINGLE DOOR (SEE NOTE 8) DOOR DESIGN PRESSURE = +75 / -75 PSF DESIGN PRESSURES FOR DOORS, ALL GLASS TYPES UNREINFORCED DOOR TO SIDE LITE X FRAME WIDTH XX FRAME WIDTH FRAME HEIGHT 68 - 79 3/4" 70- 83 3/4" 87 3/4" 91 3/4" 80 - 95 3/4" 20 25 1/2" 40 47 3/4" +58.6F-49.0 +55.4 -55.4 +52.4 -52.4 +49.8 -49.8 +47.4 -47.4 27112" 51 3/4" +54.9 +51.8 -51.8 +49.0 -49.0 +46.5 -46.5 +44.3 -44.3 29 1 /2" 55 3W +51.7 +48.8 -48.8 +46.1 43.8 +41.6 41.6 26 31 1/2" 5° 59 3/4" +49.0 +46.2 -46.2 +43.6r38. +41.4 -41.4 +39.3 -39.3 28 33 1/2" 54 63 3/4" +43.1 +43.1 -43.1 +41.5 +39.3 -39.3 +37.3 -37:3 35 112" 67 3/4" +38.1 +38.1 -38.1 +38.1 +37.5 -37:5 +35.6 -35.6 3° 371/2" 6° 713/4"+34.0 +34.0 -34.0 +34.0 +34.0 ll34.0 TABLE 4' DESIGN PRESSURES FOR SIDE LITES UNREINFORCED DOOR TO SIDE LITE GLASS TYPE FRAME WIDTH FRAME HEIGHT 68 - 79 3/4" 70 - 83 3/4" 87 3/4" 91 3/4" 80 - 95 3/4" 10 3/4" +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 12 3/4" +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 +75.0 -75.0 19" +72.4 -72.4 +68.5 -6 +65.0 -65.0 +61.9 -6 +59.0 -59.0 A, B, C, D 213/4" +64.5 -64.5 +61.0 7.8 +55.0 -55.0+52.4 -52.4 ORE 27 3/4" +52.9 -52.9 +49.9 7 44.7 -44.7 +42.6 -42.6 36 1/8" +35.2 -35.2 +35.2 5.2 +35.2 -35.2 +34.4 -34.4 36 3/4" +34.0 -34.0 +34.0 -34.0 +34.0 -34.0 +34.0 -34.0 +34.0 -34.0 FOR MAX. SIZES OF COMBINED UNITS, SEE SHEETS 10-13. EXAMPLE 2, (USING TABLES 1 & 2): OXXO WITH GLASS TYPE A, REINFORCED, 68" WIDE X 85" HIGH DOUBLE DOOR WITH (2) 36-1/2" X 85" SIDE LITES (SEE NOTE 8) DOOR DESIGN PRESSURE = +75 / -75 PSF SIDE LITE DESIGN PRESSURE = +70.4 I -70.4 PSF OVERALL DESIGN PRESSURE = +70.4 / -70.4 PSF EXAMPLE 4, (USING TABLES 3 & 4): OXXO WITH GLASS TYPE B, UNREINFORCED, 71-3/4" WIDE X 95-3/4" HIGH DOUBLE DOOR WITH (2) 36-3/4" X 95-3/4" SIDE LITES DOOR DESIGN PRESSURE = +34 / -34 PSF SIDE LITE DESIGN PRESSURE _ +34 / -34 PSF OVERALL DESIGN PRESSURE _ +34 / -34 PSF EXAMPLE 6, (USING TABLE 1): XX WITH GLASS TYPE A, 63-3/4" WIDE X 91-3/4" HIGH DOUBLE DOOR (SEE NOTE 8 DOOR DESIGN PRESSURE = +75 / -75 PSF 1) FOR CONFIGURATIONS WHICH CONTAIN A SIDE LITE TO DOOR CONNECTION, (XO, OX, XXO, O.XX, OXO, OXXO), THE LOWEST DESIGN PRESSURE SHALL PREVAIL. 2) FULL LENGTH REINFORCEMENT (ITEM 22 SHOWN IN SECTION E-E, SHEET 4), IS REQUIRED AT DOOR TO SIDE LITE CONNECTIONS, WHEN USING TABLES 1 & 2. 3) DOOR AND SIDE LITE COMBINATIONS FROM TABLES 3 AND 4 DO NOT REQUIRE REINFORCEMENT ITEM 22. 4) DESIGN PRESSURES UNDER 40 PSF ARE NOT APPLICABLE IN MIAMI-DADE COUNTY. 5) FOR DOOR -ONLY CONFIGURATIONS (X, XX), ONLY TABLE 1 IS APPLICABLE. REINFORCEMENT, PART #22, IS NOT REQUIRED. 6) FOR SINGLE, STAND-ALONE SIDE LITES (0), ONLY TABLE 2 IS APPLICABLE. REINFORCEMENT, PART #22, IS NOT REQUIRED 7) CONFIGURATIONS WHERE THE DOOR LOCKSTILE ABUTS A SIDELITE ARE NOT AVAILABLE WITH REINFORCEMENT. 8) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. (E.G. FOR 32" "X" DOOR WIDTH IN TABLE 3, USE 33-1/2") GLASS TYPES (ALL TABLES, THIS SHEET): A. 3/8" LAMI (1/8" A, .090 PVB, 3/16" HS) B. 3/8" LAMI (1/8" HS, .090 PVB, 3/16" HS) C. 7/16" LAMI (3/16" A, .090 PVB, 3/16" HS) D. 7/16" LAMI (3/16" HS, .090 PVB, 3/16" HS) E. 13/16" LAM[ IG (3/16" TP, 1/4" AIRSPACE, 1/8" HS, .090 PVB, 3/16" HS) ftomc ri REV as complying with the F' od& )kM;ng Cade Aeeepteacc No 2t:-4'107 O Xx,*ration Date Z•- H) ADDED DESCRIPTION TO O TABLE HEADERS. - AK - 04/15/20 N Y = C) na8 D_ o O U) ti O a}Da (9 � OM o OTC) Z = al U CD uj Xa ON DMa 00 W UMDJa I- W O 7 o Iq r Z v W 0 to (n 06 U- O 0' cV O (A }mays co O w D' m cn z o U z (n Z F mu) W D_ W D- 5105s � � Z O o. Q w 0 a aq�l •�sao sauas ENV LYN/v��'%,�� Flo. 58705 , �Q� •. 7E� t(� ••. G(�� i .PtORIOP. N C� ,,; DNA I A. LYNN MILLER, P.E. P.E.# 58705 EXTERIOR INTERIOR UTAX. lOOR RAME EIGHT SL SECT. B-B VERTICAL INTERIOR MAX. SIDE LITE FRAME HEIGHT CLEAR -COLORED SEALANT 63 EXTERIOR INTERIOR SL VIEW G-G CORNER ASSEMBLY 6q,) AT HEAD/JAMB 6�j) AT SILUJAMB H) NO CHANGES THIS SHEET. - O04/15/20 N Y 2 nary O ❑ � cn O a}op U� N O O M o Z W �- Z u' = W 07 rg WU 0 uMo�p *ON 9Mp ❑Lo oZrn LL 06 O w M O (A }aays cD O Z ® N ❑ O = z U U Z o z W W U) aloas LL Q U J U) o J W Q > ❑ LL a!}!1 •asap sauas ANY •LYNy� OCENSF NO. 58705' �O� . STATE F ��: A. LYNN MILLER, P.E. P.E.# 58705 DOORS. 20 Io MAX. 'X' FRAME WIDTH �j SPACING, SAME AS 3l4" JAMB ANCHOR SPACING 67 (SEE SHEETS 7, 8 AND 9) MAX. SL FRAME WIDTH SEE NOTE 3, 22 fT- DLo THIS SHEET 62 S L SECT. E-E 62 6.6 HORIZ. (DOOR W/ SIDE LITE) REINFORCEMENT NOT REQUIRED FOR STAND-ALONE 'X' DOORS. REINFORCEMENT MAX. SL FRAME WIDTH-----�-{ NOT REQUIRED FOR STAND-ALONE 'O' _MAX. t"� DLO SL SECT. F-F HORIZ. (SINGLE SIDE LITE) INTERIOR EXTERIOR NOTES: 1) CLEAR OPENING FOR'X' AND 'XX' DOORS AS FOLLOWS: WIDTH: X' DOORS = DOOR FRAME WIDTH - 5.646 XX' OR = DOOR FRAME WIDTH / 2 - 4,079 HEIGHT: DOOR FRAME HEIGHT - 3.259" 2) SIDE LITES OVERLAP'X' AND'XX' DOORS BY 3%4" WHEN ASSEMBLED TO MAKE'XO', 'OX', 'OXO"XXO', 'OXX' AND'OXXO' CONFIGURATIONS. 3) FULL LENGTH REINFORCEMENT APPLICABLE TO DOOR AND SIDE LITE COMBINATIONS FROM TABLES 1 AND 21 SHEET 2. ITEM 22 IS NOT REQUIRED WITH COMBINATIONS FROM TABLES 3 AND 4, SHEET 2, OR WITH STAND-ALONE'O', CONFIGURATIONS FROM TABLES 1 AND 2, H) NO CHANGES THIS SHEET. - AK- 04/15/20 N Y = O nab o O Q O 9IDa C7 LO o Zo w Xe W U LU UMDJCI D 'N 1- J 0Ma LZIJ ~o > rn o LL. 06 c() O O O 1aa4S m 0 ® N p U c\I0U) Z O Z -� w < a1DDS LL Z :�i O N o LU Q00 LL al}11 rosaa sauas . ' LIGENSF _ No, 58705 - O� '. S9ATE F \ i �S1 ••, 4ORIOF.• /ONAL 1111111 W A. LYNN MILLER, P.E. P.E.# 58705 ITEM DWG # PGT# DESCRIPTION 1 943B 60411 FRAME HEAD 2 1010 ago 6Q300 WSTP.,Q-LON .190 X.375 HIGH 3 7070 67070K BULB WEATHERSTRIP .187 X.300 HIGH 4 955 7955X FLUSHBOLT STRIKEPLATE 5 938 7938X 2 PT. LOCK STRIKEPLATE 6 FRAME HEAD STRIKEPLATE BACKING PLATE 712FPXP #8-32 X.500 PH. FL. MS - S.S. W/SILICONE PATCH 8 GASKET (BETWEEN THRESHOLD & FRAME JAMB) 9 &6533016 GASKET (BETWEEN HEAD & FRAME JAMB) 10 16 FILLER HEAD ADAPTER 11 0M OUTSWING THRESHOLD 12 0 WSTP, .350 RD FOAM FILL TSLOT (AMSBURY#32011) mwaa�aaw13 1waa 1004A 611004M I OUTSWING THRESHOLD CHANNEL COVER 14 11001A 411001A ACETAL SPACER .065 @ THRESHOLD, OPTIONAL 15 11002A 411002A ACETAL SPACER .095 @ THRESHOLD, OPTIONAL 16 11003A 411003A ACETAL SPACER .140 @ THRESHOLD, OPTIONAL 20 915D 60380 FRAME JAMB (OUTSWING) 21 1010 6Q300 WSTP.,Q-LON A90 X.375 HIGH 22 6608 66608M REINFORCEMENT, 1,000 X 2.750 X 0.650, 6061-T5 23 11140 78X112PSATS JL8 X 1,500 PH SQ A T/S 24 1048 71048 JAMB SCREW COVER CAP 25 930 41721N STRIKE PLATE INSERT 26 1118 71OX34PFA #10 X.750 PH. FL, SMS 27 7070 67070K BULB WEATHERSTRIP A87X.300 HIGH 30 910D 6910 DOOR PANEL, TOP & BOTTOM RAIL 31 911E 6911 DOOR PANEL, SIDE RAIL 32 1917 7FRMO HINGE EXTRUSION 33 1178 71058FP W,B #10 X.625 PH. FL SMS 34 913A 60378M TRUSS CLAMP 35 1130 6TRODA 5/1&18 THREADED ROD 36 990 7990NUTA 5/16-18 FLANGED HEX NUT 37 914A 60379M WEATHERSTRIP CHANNEL 38 7834FPT #8 X.75 PH, FL, TEK 39 1997 70997 GASKET (BETWEEN PANEL HEAD/SILL & PANEL STILES) 40 1023 67924G WSTP., .187 X.250 HIGH, FINSEAL 41 928 41720 SLIDE BOLT ASSY. (INACTIVE PANEL ONLY) 42 1145 76X12FPAW #6X.500 PH FL SMS TYPE BDS 43 1212 7P30GG SILL DUST PLUG (INACTIVE PNQ 44 983B 6983 DOOR PANEL ASTRAGAL 1 (OUTSWING) 45 984B 6984 DOOR PANEL ASTRAGAL 2 (OUTSWING) 46 1213 6Q200K WSTP.,Q-LON .190 X.200 HIGH 47 929 74UBLOK LOCK SUPPORT ASSY. (41707 & 41708) 48 1139 7634F #6 X .750 PH. FL, SMS 49 982 FD2PTAY 2 PT, LOCK ASSY, 50 6R180FS RUBBER SLEEVE 51 930 41721 STRIKE PL, INSERT (INACTIVE PANEL) 52 931 7FRSPX DEADBOLTSTRIKE PLATE 53 1118 710X34PFA #10X.750 PH FL. SMS 54 957 70957X HANDLE STRIKE PLATE 55 1118 71 OX34PFA #10 X .750 PH FL. SMS 60 920D 6920D SIDELITE HEADER 61 921D 6921 SIDELITE SILL 62 9168 60381 SIDELITE JAMB 63 1155 781PQA #8 X 1.000 QUAD PN, SMS 64 998 7998 HEAD GASKETS (STOCKING #70998) 65 999 7999 SILL GASKETS (STOCKING #70999) 66 934A 61641M SIDELITE JAMB ADAPTER 67 #12 X 1,000 SHEET METAL SCREW 70 712653K SETTLING BLOCK, 3/32" X 1/4" X 1" W/PSA 71 71267K SETTING BLOCK, 1/16" X 112" X 1" W/PSA 72 4222A 64222 BEAD, 7116" 73 988 6988 BEAD, 3/8" 74 988 IG BEAD 92 986 64986 BEAD, INTERIOR 93 1224 6TP247 BULB, THICK (USED IN EXTRUDED BEAD) 94 GLAZING SILICONE, DOW 899 OR 983 OR 791 95 GLASS, 3/8" LAMI - 1/8" A, .90 PVB, 3116" HS 96 GLASS, 3/8" LAMI - 1/8" HS, .90 PVB, 3/16" HS 97 GLASS, 7/16" LAW - 3/16" A, .90 PVB, 3/16" HS 98 GLASS, 7/16" LAMI - 3/16" HS, .90 PVB, 3/16" HS 102 11006A 141106A JACETAL SPACER .295 @ THRESHOLD, OPTIONAL 103 jOFFmTHE SHELF IDEAD BOLT LOCK, MIN 1" THROW, GR 3 STEEL 104 IOFF=THE SHELF HANDLE/LATCH ASSEMBLY, MIN 7/16" THROW, GR 3 STEEL ITEMS # 17-191 28, 29, 56-591 68, 69, 75-79, 84-91 & 99-101 ARE NOT USED AND ARE NOT PART OF THIS APPROVAL. STRUCTURAL POLYISOBUTYLENE WITH DESICCANT EXT. GLASS STRUCTURAL SILICONE FOAM WITH DESICCANT EXT. GLASS BUTYL & DESICCANT FOAM EXT. GLASS POLYISO- BUTYLENE SEAL ROLL -FORMED STAINLESS STEEL EXT. -GLASS LICONE 1/4" NOM. KODISPACE 80 4SG TPS INT. GLASS OT-MELT BUTYL —3l16" NOM. SUPER 81 SPACER® NXT'"' INT. GLASS ALUMINUM REINFORCEMENT 5/16" NOM D U RAS EAL® 82 SPACER INT. GLASS DESICCANT FILL AREA 5/16" NOM. SILICONE SEAL XL TM 83 SPACER INT. GLASS Part # Description Material 80 Kommeding 4SG TPS Spacer System aaaaaamm See this 81 Quanex Super Spacer nXT with Hot Melt Butyl Sheet for 82 Quanex Duraseal Spacer Materials 83 Cardinal XL Edge Spacer REFERENCE TEST REPORTS: FTL-8717, 8968 & 8970 H) ADDED BACKBEDDING. - AK - 04/15/20 O nay O O i- O 0100 Ci N o O m Z o O vmm r- � 2 W `amw WC) 0 � umoip 'oN J 9Mp ti �T now W cA oz� UTaaa LL uiS Q O u7 WFogg m Q Iaa4S ® rn (!) = W U Z U o z a agog H W (n aloaS LL Z J 07 Q o w � Q O p mLL t) 1,0990 sauaS ��•' �tCENSF ' ,��� �% No, 58705 aawr ^�O••�. S�ATEO�•••(v� S goat C� s/ONAL A. LYNN MILLER, P.E. P.E.# 58705 1.750 1.750 1.750 1.750 .os2 062 4.100 .062 4.100 .062 4.100 4.000 4.675 4.675 DOOR PANEL DOOR PANEL DOOR PANEL 30 TOP & BOTTOM RAIL 31 SIDE RAIL DOOR PANEL 6063-T5 6063-T5 44 INTERIOR ASTRAGAL 45 EXTERIOR ASTRAGAL 6063-T5 6063-T5 3.655 3.t11 550 1.400 7,050 1 Q FILLER HEAD ADAPTER 6063-T6 3.000 ►{ 1.272 1.479 OFRAME HEAD 6063-T6 .050 .079 1.489 489 3.000 ►� �-+--1.500 6.085 750 TRUSS CLAMP 6063-T5 .805 f --�- 050 .683 D3/16" GLAZING BEAD 6063-T5 .075 750 3.100 OOUTSWING THRESHOLD SL HEADER SL SILL 11 6063-T6 6Q 6063-T6 61 6063-T6 050 683ft� - D5/8" GLAZING BEAD 6063-T5 5.212 .05( 3.000 1.480 7 20 DOOR FRAME JAMB 6063-T6 +-1.578 .890 150 3.000 SL JAMB 6063-T6 050 1.620 �- 37 WEATHER STRIP CHANNEL 6063-T5 QJ.375 2 125 32 HINGE 6063-T5 f-�-----.172 41 050 .683 ►� 1.092 .74 IG GLAZING BEAD 6063-T5 .504 --►-� �, 360 .055 - ►�-� 13 OUTSWING THRESHOLD CHANNEL COVER 6063-T6 2.750 --�{ �0 .650 ---� SL JAMB 66 ADAPTER 22 6063-T6 .125 J TUBE MULL 6063-T6 H) CORRECTED TUBE MULL TEMPER. 04/15/20 N Y = nab} O o O 0 0 a}op C M O O Z w WU uMo�p .oN 0Mp Lo LL xs O m Q }aa4S co ® p � U Z o Z � h W Z a1o�S � O � U- U) � w O W LL aµ l --nsap sauaS �• pN\' LYN�V '�•� ' No, 58705 -Z0 as �; O^ ATE F s/ONAL `E�G��\ A. LYNN MILLER, P.E. P.E.# 58705 TGRI F F• X DOORS, ALL GLASS TYPES ANCHOR TYPE & SUBSTRATE 2, 3, WOOD 3 ALUM 1 1,2, CONC LOAD ZONES m ¢ x U J o Q x - m g x U J o Q x MAX DOOR FRAME WIDTH MAX HER 25.50 79.75 83.75 87.75 91.75 95.75 5 2 4 2 5 2 4 2 5 2 4 2 5 2 4 2 1 6 2 4 1 2 27.50 79.75 83.75 87.75 91.75 95.75 5 2 4 2 5 2 4 2 5 2 4 2 6 2 4 2 6 2 4 2 29.50 79.75 83.75 87.75 91.75 95.75 5 2 4 2 5 2 4 2 6 2 4 2 6 2 4 2 6 2 4 2 31.50 79,75 83.75 87.75 91.75 95.75 5 2 4 2 6 2 4 2 6 2 4 2 6 2 4 2 7 2 4 2 33.50 79.75 83.75 87.75 91.75 95.75 6 3 4 3 6 3 4 3 6 3 4 3 7 3 4 3 7 3 4 3 35.50 79.75 83.75 87.75 91.75 95.75 1 6 3 4 3 6 3 4 3 6 3 4 3 7 3 4 3 7 3 4 3 37.50 79.75 83.75 87.75 91.75 95.75 6 3 4 3 6 3 4 3 7 3 4 3 7 3 4 3 7 3 4 3 20-7/8" MAX. O.C. 6" A -A MAX. / 84-3/8" MAX. DLO O LV24/16\ DLO\ 13-1 /4" MAX. 23-1 /8" MAX. O.C. 3 37-1/2" MAX. DOOR FRAME WIDTH TYP. DIMENSIONS OF SINGLE DOOR, X NOTES: 40" (TYP.) 95-3/4" MAX. FRAME HEIGHT HEAD ZONE "C" w z 0 N m 1 SILL !� ZONE "C' LOAD ZONES FOR SINGLE DOOR, X 1) SEE SHEET 1 FOR GLASS AND ANCHOR TYPE DESCRIPTIONS. 2) DOORS MAY BE LEFT OR RIGHT-HANDED. 3) ANCHOR QUANTITIES ARE BASED ON SPACING AS FOLLOWS (4" MIN. O.C. FOR CONCRETE, 4" MIN. O.C. FOR CMU): JAMBS (ALL): 13-1/4" MAX. FROM CORNERS AND 23-1/8" MAX. O.C. HEAD & SILL OF DOORS: 6" MAX. FROM CORNERS, 9" MAX. FROM ASTRAGAL CENTERS AND 20-718" MAX. O.C. 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 5) FOR ANCHORAGE INSTALLATION DETAILS SEE SHEET 14. w z 0 N m Q Design Pressure See Sheet 2, Table 1 8, po ft witY ft FiorWL Aftepta ct N 1 o I A,�ptaace No �' Date a H) NO CHANGES THIS SHEET. - AK - 04/15/20 N Y 2 O �a� 0 o O ti (7 N O r u) a;pQ O M Z O O � 0 W 2 LLI -, U U O W . N O 9M0 W OD F- ' J uMoJp W r` > W CC:-) Z 0)0 LO 05 LL O w ti O 3aa45 rn ® 04 O rn N z U) C) Z o Z FQ- W J aloes IL 0 W o cc J Q X T7 LL aP. asap sauas No. 58705 441, 0 , STATE OF (V \ in s '.F<ORIDP,. NAL I�� A. LYNN MILLER, P.E. P.E.# 58705 TARL_F 6' XX DOORS, ALL GLASS TYPES ANCHOR TYPE & 21 31 WOOD 1121 CONC SUBSTRATE 3 ALUM LOAD ZONES i QMAX Q MAX i DOOR FRAME FRAME <j w _ �¢ WIDTH HEIGHT X X X X i 47.75 79.75 4 3 i 4 j 2 5 4 4 j 2 83.75 5 4 4 2 87.75 5 4 4 2 91.75 95.75 5 4 4 j 2 51.75 79.75 5 4 4 2 83.75 5 4 4 i 2 87.75 5 4 4 ( 2 5 4 4 j 2 91.75 6 4 4 3 95.75 55.75 79.75 5 4 4 ; 2 5 4 4 2 83.75 87.75 5 4 4 i 2 6 4 4 3 91.75 6 4 4 3 95.75 59.75 79.75 5 5 4 j 2 83.75 5 5 4 2 6 5 1 4 1 3 87.75 91.75 6 5 4 1 3 6 5 4 ; 3 95.75 63.75 79.75 5 5 4 ! 2 83.75 6 5 4 3 6 5 4 3 87.75 91.75 Z 5 4 1 3 95.75 7 6 4 1 3 67.75 79.75 6 5 4 3 83.75 6 5 4 ( 3 6 5 4 3 87.75 91.75 7 6 4 3 7 6 4 3 95.75 71.75 79.75 6 5 4 3 83.75 6 5 4 ! 3 87.75 6 5 4 1 3 91.75 7 6 4 1 3 95.75 7 6 4 3 20-7/8" MAX. O.C. 6 -► { 9" MAX. q-A 3 I i I I 84-3/8" MAX. DLO / 24-9/16\ MAX. DLO\ / I IL-4 3 71-3/4" MAX. DOOR FRAME WIDTH MAX. 23-1l8" MAX. O.C. TYP. ELEVATION OF XX CONFIGURATION HEAD ZONE "D" 9„ HEAD MAX. ZONE "D" LOAD ZONES FOR XX CONFIGURATION & ANCHORAGE LAYOUT USED IN EXAMPLE 95-3/4" MAX. FRAME HEIGHT c. Design Pressure See Sheet 2, Table 1 NOTES: 1) SEE SHEET 1 FOR GLASS AND ANCHOR TYPE DESCRIPTIONS. 2) DOORS MAY BE LEFT OR RIGHT-HANDED. 3) ANCHOR QUANTITIES ARE BASED ON SPACING AS FOLLOWS (4" MIN. O.C. FOR CONCRETE, 4" MIN. O.C. FOR CMU): JAMBS (ALL): 13-1/4" MAX. FROM CORNERS AND 23-1/8" MAX. O.C. HEAD & SILL OF DOORS: 6" MAX. FROM CORNERS, 9" MAX. FROM ASTRAGAL CENTERS AND 20-7/8" MAX. O.C. 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 5) FOR ANCHORAGE DETAILS SEE SHEET 14. EXAMPLE: XX WITH GLASS TYPE A, 63-3/4" WIDE X 91-314" HIGH DOUBLE DOOR, ANCHOR TYPE 3 INTO WOOD DESIGN PRESSURE = +75 / -75 PSF, SEE EXAMPLE 6, SHEET 2 FOR DP EXAMPLE BOOR ANCHOR REQUIREMENTS FROM TABLE 6: 6 ANCHORS @EACH JAMB 5 ANCHORS EACH DOOR PANEL @ HEAD 5 ANCHORS EACH DOOR PANEL @ SILL OSEE CIRCLED VALUES ON TABLE 6. X =DENOTES ANCHOR LOCATION, H) NO CHANGES THIS SHEET. - AK - 04/15/20 LYNIiV N Y = O nab � � O o U) O a}op U` N Uv) O OM O Z w WU 0 � uMnip 'ON 0Mp o ) p � Z 06 O fl� OD 0 }aa4S rn ® p U) (3 Z z o Z 1- 00 aloa5 LL Q �. W 0 W C) � T Q U. awl -asap IS9.1jas Qr No.58705 TAT rF*' ��� O E �f/j111110\\ A. LYNN MILLER, P.E. P.E.# 58705 TABLE 7: O SIDE LITE, ALL GLASS TYPES ANCHOR TYPE & 2, 31 WOOD 1,2, CONC SUBSTRATE 3 ALUM LOAD ZONES w w m = J J 0 ! J 47 J - m co MAX MAX SIDE LITE FRAME Q 2 w FRAME HEIGHT � WIDTH O 1 O i 1 O O 10.75 79.75 4 1 4 j 1 83.75 4 1 4 1 87.75 4 1 4 1 91.75 4 1 4 ; 1 4 1 4 j 1 95.75 12.75 79.75 4 2 4 2 83.75 4 2 4 i 2 87.75 4 2 4 ! 2 4 2 4 2 91.75 95.75 4 2 4 2 19.00 79.75 4 2 4 i 2 83.75 4 2 4 2 4 2 4 ? 2 87.75 4 2 4 2 91.75 95.75 4 2 4 2 21.75 79.75 4 2 4 ! 2 83.75 4 2 4 2 4 2 4 2 87.75 91.75 5 2 4 2 95.75 5 2 4 2 27.75 79.75 5 2 4 2 83.75 5 2 4 j 2 87.75 5 2 4 j 2 91.75 6 2 4 2 95.75 6 2 4 ; 2 36.13 79.75 6 3 4 3 6 3 4 i 3 83.75 87.75 7 3 4 3 91.75 7 3 4 ; 3 95.75 7 3 4 3 36.75 79.75 6 3 4 3 83.75 6 3 4 j 3 87.75 7 3 4 i 3 91.75 7 3 4 3 95.75 7 3 4 3 17-718" MAX. O.C. 13-1/4" MAX. 23-1 8 O MAX. O.C. / 84-3/8" MAX. U 33-5/8" MAX. DLO I B-B I 3 36-3/4" MAX. IDE LITE FRAME WIDTH TYP. ELEVATION OF SINGLE SIDELITE, O NOTES: 1) SEE SHEET 1 FOR GLASS AND ANCHOR TYPE DESCRIPTIONS. 95-3/4" MAX. FRAME HEIGHT HEAD �-ZONE"E" I LOAD ZONES FOR SINGLE SIDELITE, O 2) ANCHOR QUANTITIES ARE BASED ON SPACING AS FOLLOWS (4".MIN. O.C. FOR CONCRETE, 4"MIN. O.C. FOR CMU): JAMBS (ALL): 13-1/4" MAX. FROM CORNERS AND 23-1/8" MAX. O.C. HEAD & SILL OF SIDE LITES: 6" MAX. FROM CORNERS AND 24-3/4" MAX. O.C. 3) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE. 4) FOR ANCHORAGE INSTALLATION DETAILS SEE SHEET 15. Design Pressure See Sheet 2, Table 2 H) NO CHANGES THIS SHEET. - AK - 04/15/20 N Y 2 O naa o O 'n O a�DQ () N Lo p m U)o O�� w r J t„ U 0Ka W-' IJMDJQ ON omo �' IOU oZ3) tL ai O IY m }aa4S rn 0 ® rn p U) cq z U Z o Z F- w a�D�S tL 3 o Iw a J 0 `; Q O 0 a��l •asaQ sauas Y LYNN!�i���'; '• l _r No. 58705 - OF (V ` i � •'•FLORID,.•' \�� /0nIAL E`' �`• �//fl111111\\ A. LYNN MILLER, P.E. P.E.# 58705 m:r� xo & ox, ALL GLASS TYPES ANCHOR TYPE & SUBSTRATE 21 31 WOOD 3 ALUM 132, CONC LOAD ZONES m 2 O w i-n w O a w _ x Q 2 ¢ I x m 2 O iu w O o w x Q 2 x MAX SIDE LITE FRAME WIDTH MAX'X DOOR FRAME WIDTH FRAME HEIGHT 10.75 25.50 79.75 83.75 87.75 91.75 95.75 4 2 3 5 4 2 2 4 4 2 4 5 4 2 2 4 4 2 4 5 4 2 2 4 4 2 4 5 4 2 2 4 4 2 4 6 4 2 2 4 12.75 27.50 79.75 83.75 87.75 91.75 95.75 4 2 4 5 4 2 2 4 4 2 4 5 4 2 2 4 4 2 4 5 4 2 2 4 4 2 4 6 4 2 2 4 4 2 4 6 4 2 3 4 19.00 29.50 79.75 83.75 87.75 91.75 95.75 4 3 4 5 4 2 2 4 4 3 4 5 4 2 2 4 4 3 4 6 4 2 2 4 4 3 4 6 4 2 3 4 r4 3 4 6 4 2 3 4 21.75 31.50 79.75 83.75 87.75 91.75 95.75 4 3 5 5 4 2 2 4 4 3 5 6 4 2 2 4 4 3 5 6 4 2 3 4 5 3 5 6 4 2 3 4 5 3 5 7 4 2 3 4 27.75 33.50 79.75 83.75 87.75 91.75 95.75 5 3 5 6 4 2 2 4 5 3 5 6 4 2 3 4 5 3 5 6 4 2 3 4 6 3 5 7 4 3 3 4 6 3 6 7 4 3 3 4 36A3 35.50 79.75 83.75 87.75 91.75 95.75 6 4 5 6 4 3 3 4 6 4 5 6 4 3 3 4 7 5 5 6 4 3 3 4 7 5 6 7 4 3 3 4 7 5 6 7 4 3 3 4 36.75 37.50 79.75 83.75 87.75 91.75 95.75 6 4 5 6 4 3 3 4 6 4 5 6 4 3 3 4 7 5 5 7 4 3 (3)_(4 7 5 6 7 4 3 3 4 7 5 6 7 4 3 3 4 ANCHOR QUANTITIES FOR THE DOOR AND SIDE LITE TO BE DETERMINED INDEPENDENTLY, 9" MAX. 20-7/8" MAX. O.C. 6" MAX. I A3 MAX. O.C. 13-1/4" MAX. 37-1 /2" MAX. DOOR FRAME WIDTH 6" MAX. BB I 3 I \ \ j\ 84�m MAAX.X, " DLO E-ELO / / / / 4 24-9/16" / MAX. DLO SEE TABLES 141 SHEET 2FOR REINFORCEMENT REQUIREMENTS. / I I I I I I 33-5/8" MAX. DLO I 73-1/2" MAX. DOOR +SIDE LITE FRAME WIDTH 13-1/4" MAX. 95-3/4" MAX. FRAME HEIGHT Design Pressure Reinforced: See Sheet 2, Tables 1 & 2 Unreinforced: See Sheet 2, Tables 3 & 4 NOTES: 1) SEE SHEET 1 FOR GLASS AND ANCHOR TYPE DESCRIPTIONS: 2) DOORS MAY BE LEFT OR RIGHT-HANDED. 3) ANCHOR QUANTITIES ARE BASED ON SPACING AS FOLLOWS (4" MIN. O.C. FOR CONCRETE, 4" MIN, O.C. FOR CMU): JAMBS (ALL): 13-1/4" MAX. FROM CORNERS AND 23-1/8" MAX. O.C. HEAD &SILL OF DOORS: 6" MAX. FROM CORNERS, 9" MAX. FROM ASTRAGAL CENTERS AND 20-7/8" MAX. O.C. HEAD & SILL OF SIDE LITES: 6" MAX. FROM CORNERS AND 24-3/4" MAX. O.C. 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE, 5) FOR ANCHORAGE INSTALLATION DETAILS SEE SHEETS 14 & 15. 36-3/4" MAX. SIDE 6) CONFIGURATIONS WHERE THE DOOR LOCKSTILE LITE FRAME WIDTH ABUTS A SIDE LITE ARE NOT AVAILABLE WITH REINFORCEMENT. TYP. ELEVATION OF XO CONFIGURATION SOX SIMILAR) HEAD ZONE "D" HEAD ZONE to IF 6" MAX. 9" MAX. -i--I MAX. 6" MAX. 9" MAX. SILL ZONE "D" SILL ZONE LOAD ZONES FOR XO CONFIGURATION & ANCHORAGE LAYOUT USED IN EXAMPLE (OX SIMILAR) 7) SIDE LITE OVERLAPS DOOR BY 3/4" ONCE ASSEMBLED. EXAMPLE: XO WITH GLASS TYPE B, 84" SINGLE DOOR WITH 36" X 84" WIDE SIDE LITE, ANCHOR TYPE 3 INTO CONC, DOOR DESIGN PRESSURE = +75 / -75 PSF DOOR ANCHOR REQUIREMENTS FROM TABLE 8: 4 ANCHORS @.DOOR JAMB 3 ANCHORS @ DOOR PANEL @ HEAD 3 ANCHORS @ DOOR PANEL @ SILL 4 ANCHORS @ SIDE LITE JAMB 3 ANCHORS @ SIDE LITE @ HEAD 3 ANCHORS @ SIDE LITE @ SILL OSEE CIRCLED VALUES ON TABLE 8. X =DENOTES ANCHOR LOCATION. H) NO CHANGES THIS SHEET. - AK - 04l15/20 Y = wit O U) nay O O a 07 p (7 N p O M o O rcun) Z LU r- = w �e V U 0 W un+o�a 'ON W ~ Dmc > W �r) O Z ) r- � ti 06 O o p r Pa4S p ® N 0 c>7 cn z U Q z p z H F W W 0 aloaS w W Q J � w °6 O Df ¢ O 0 X al3l1 •asap sauas Ll'h�'%,, / ��GErvs _ No. 58705 ��� '•.'cCORIDP.•'�• �.�� /ONAL ' �. A. LYNN MILLER, P.E. P.E.# 58705 TAR[ F Q• OXO, ALL GLASS TYPES ANCHOR TYPE & SUBSTRATE 213, WOOD 1 2 CONC 3 ALUM LOAD ZONES iu ii w I i� m J J_ `� m U) ' ¢ MAX MAX 'x MAX SIDE LITE DOOR Q Q 2 i Q FRAME FRAME FRAME HEIGHT _ _ ¢ _ ' _ WIDTH WIDTH O O 1 x 10 O! x 10.75 25.50 79.75 4 2 7 4 2 3 83.75 4 2 7 4 2 3 87.75 4 2 7 4 2 J 3 4 2 7 4 23 91.75 95.75 1 4 2 7 4 2 3 12.75 27.50 79.75 4 2 7 4 2 1 3 83.75 4 2 7 4 2 1 3 87.75 4 2 7 4 2 1 3 4 2 7 4 2? 5 91.75 95.75 4 2 7 4 2 i 5 19.00 29.50 79.75 4 3 8 4 2 3 4 3 8 4 2 1 3 83.75 87.75 4 3 8 4 2 i 5 91.75 4 3 8 4 2 5 4 3 8 4 2 1 5 95.75 21.75 31.50 79.75 4 3 8 4 2 3 4 3 8 4 2 j 5 83.75 87.75 4 3 8 4 2 1 5 5 3 8 4 2 5 91.75 95.75 5 3 10 4 25 27.75 33.50 79.75 5 3 8 4 2 3 83.75 5 3 8 4 2 5 5 3 8 4 2 5 87.75 6 3 101 4 3 5 91.75 6 3 10 4 3 5 95.75 36.13 35.50 79.75 6 4 8 4 3 5 6 4 8 4 3 5 83.75 758 4 3 5 87.75 91.75 7 5 10 4 3 5 95.75 7 5 10 4 3 j 5 36.75 3T50 79.75 6 4 8 4 3 j 5 83.75 6 4 8 4 3 5 7 5 10 4 3 1 5 87.75 7 5 10 4 3 1 5 91.75 7 5 10 4 3 1 5 95.75 ANCHOR QUANTITIES FOR THE DOOR AND SIDE LITE TO BE DETERMINED INDEPENDENTLY. 20-7/8" MAX. O.C. 6 Imo- 6 MAX. -�j F A -A MAX. I � � � 3 i 23-1/8" MAX. O.C. 6" MAX. 6" MAX. B-B �- I La / I I I I I AA I I BB 36-3/4" MAX. SIDE 3 3 LITE FRAME WIDTH 37A/2" MAX. DOOR FRAME WIDTH 109-1/2" MAX. DOOR + SIDE LITE FRAME WIDTH TYP. ELEVATION OF OXO CONFIGURATION (NOT AVAILABLE WITH REINFORCEMENT] HEAD HEAD HEAD ZONE "Ell ZONE "F" ZONE "Ell ZONE "E" ZONE "F" ZONEL"E" LOAD ZONES FOR OXO CONFIGURATION 24-3/4" MAX. O.C. 13-1 /4" MAX. 95-3/4" MAX. FRAME HEIGHT NOTES: Design Pressure Reinforced: N/A Unre(nforced: See Sheet 2, Tables 3 & 4 1) SEE SHEET 1 FOR GLASS AND ANCHOR TYPE DESCRIPTIONS. 2) DOORS MAY BE LEFT OR RIGHT-HANDED. 3) ANCHOR QUANTITIES ARE BASED ON SPACING AS FOLLOWS O.C. FOR CONCRETE, 4" MIN. O.C. FOR CMU): JAMBS (ALL): 13-1/4" MAX. FROM CORNERS AND 23-1/8" MAX. O.C. HEAD & SILL OF DOORS: 6" MAX. FROM CORNERS, 9" MAX. FROM ASTRAGAL CENTERS AND 20-7/8" MAX. O.C. HEAD & SILL OF SIDE UTES: 6" MAX. FROM CORNERS AND 24-3/4" MAX. O.C. 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE in SIZE. z 5) FOR ANCHORAGE INSTALLATION DETAILS SEE SHEETS 0 14 & 15. m 6) CONFIGURATIONS WHERE THE DOOR LOCKSTILE ABUTS A SIDE LITE ARE NOT AVAILABLE WITH REINFORCEMENT. 7) SIDE LITE OVERLAPS DOOR BY 3/4" ONCE ASSEMBLED. H) NO CHANGES THIS SHEET. - AK - 04/15/20 C� o _ No. 58705. _ �0 VSATEr F �WRIOP. %SS�ONAL A LYNN MILLER, P.E. P.E.# 58705 XXO & OXX, ALL GLASS TYPES ANCHOR TYPE & SUBSTRATE 213, WOOD 3 ALUM 112, CONC LOAD ZONES m ¢ O Cu J J o ¢ _ , O - ¢ co0 ¢ X J U) w _ X = J U) 0 w 2:¢ X Coco m O ui J J o ¢ z O ¢ m Q X = _J (n o w _ X u. J (n 0 w ? X MAX SIDE In FRAME WIDTH MAX ')Ox DOOR FRAME WIDTH MAX FRAME HEIGHT 10.75 47.75 79.75 83.75 87.75 91.75 95.75 4 2 4 3 6 4 2 4 2 3 5 4 7 4 2 4 2 3 5 4 7 4 2 4 2 3 5 4 7 4 2 4 2 3 T42 5 4 7 4 2 4 2 3 12.75 51.75 79.75 83.75 87.75 91.75 95.75 5 4 7 4 2 4 2 3 5 4 7 4 2 4 2 3 5 4 7 4 2 4 2 3 4 2 5 4 7 4 2 4 2 3 4 2 6 4 7 4 2 4 3 5 19.00 55.75 79.75 83.75 87.75 91.75 95.75 4 3 5 4 7 4 2 4 2 3 4 3 5 4 7 4 2 4 2 3 4 3 5 4 7 4 2 4 2 3 4 3 6 4 7 4 2 4 3 5 4 3 6 4 8 4 2 4 3 5 21.75 59.75 79.75 83.75 87.75 91.75 95.75 4 3 5 5 8 4 2 4 2 3 4 3 5 5 8 4 2 4 2 3 4 3 6 5 8 4 2 4 3 5 5 3 6 5 8 4 2 4 3 5 5 3 6 5 8 4 2 4 3 5 27.75 63.75 79.75 83.75 87.75 91.75 95.75 5 3 5 5 8 4 2 4 2 3 5 3 6 5 8 4 2 4 3 5 5 3 6 5 8 4 2 4 3 5 6 3 6 5 8 4 3 4 3 5 6 3 7 6 10 4 3 4 3 5 36.13 67.75 79.75 83.75 87.75 91.75 95.75 6 4 6 5 8 4 3 4 3 5 6 4 6 5 8 4 3 4 3 5 7 5 6 5 8 4 3 4 3 5 7 5 7 6 10 4 3 4 1 3 5 7 5 7 6 10 4 3 4 3 5 36.75 71.75 79.75 83.75 87.75 91.75 95.75 6 4 6 5 8 4 3 4 3 5 6 4 6 5 9 4 3 4 3 5 7 5 6 5 9 4 3 4 3 5 7 5 7 6 10 4 3 4 3 5 7 5 7 6 10 4 1 3 4 3 5 ANCHOR QUANTITIES FOR THE DOOR AND SIDE LITE TO BE DETERMINED INDEPENDENTLY, 20-7/8" P 6" M Design Pressure ElSee Sheet 2, Tables 1 & 2 Unreinforced: See Sheet 2, Tables 3 & 4 VIE WIDTH TYP. ELEVATION OF XXO CONFIGURATION NOTES: (OXX SIMILAR) HEAD HEAD HEAD ZONE "D" ZONE "F" ZONE "E"� / \ / \ / \ / SILL ZONEL'D" ZONE I"F" ZONE °E" LOAD ZONES FOR XXO CONFIGURATION (OXX SIMILAR) 1) SEE. SHEET 1 FOR GLASS AND ANCHOR TYPE DESCRIPTIONS. 2) DOORS MAY BE LEFT OR RIGHT-HANDED. 3) ANCHOR QUANTITIES ARE BASED ON SPACING AS FOLLOWS (4" MIN. O.C. FOR CONCRETE, 4" MIN. O.C. FOR CMU): JAMBS (ALL): 13-1/4" MAX. FROM CORNERS AND 23-1/8" MAX. O.C. HEAD & SILL OF DOORS: 6" MAX. FROM CORNERS, 9" MAX. FROM ASTRAGAL m CENTERS AND 20-7/8" MAX. O.C. Z HEAD & SILL OF SIDE LITES: 6" MAX. FROM CORNERS AND 24-3/4" MAX. O.C. N m 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT 4 AVAILABLE SIZE. 5) FOR ANCHORAGE INSTALLATION DETAILS SEE SHEETS 14 & 15. 6) CONFIGURATIONS WHERE THE DOOR LOCKSTILE ABUTS A SIDE LITE ARE NOT AVAILABLE WITH REINFORCEMENT. 7) SIDE LITE OVERLAPS DOOR BY 3/4"ONCE ASSEMBLED. H) NO CHANGES THIS SHEET. - AK - 04/15/20 N Y 2 w > C:) O nab O o 60 O t9 o �O o Zo w `- Z LL D w S W U) �g WU 0 umo-jo 'ON i- � •? J JMQ �> Lo � LL. 06 O w N O `- O U) #aa4S ® H 0 FF- (� w z o z o f- w al°oS w LL O m 06 w � O o m Q Q a1}1 asap sauaS \����Illll�rii '4� .• LICENSE' .���� �� . No. 58705 O^ '. STACTTF S ///11tli110\� A. LYNN MILLER, P.E. P.E.# 58705 TART F 1I• OXXO, ALL GLASS TYPES ANCHOR TYPE & SUBSTRATE 29 31 WOOD 112, CONC 3 ALUM LOAD ZONES W iL = w - J m m o m i MAX MAX ')N SIDE LITE DOOR MAX Q w :E ¢� w FRAME FRAME FRAME ¢ w _ = , ¢ � w I = 1:WIDTH WIDTH HEIGHT o O X O O j X 10.75 47.75 79.75 4 2 161 4 2 1 3 4 2 7 4 2 3 83.75 4 2 7 4 2 i 3 87.75 91.75 4 2 7 4 2 j 3 95075 4 2 7 4 2 3 12.75 51,75 79.75 4 2 7 4 2 3 4 2 7 4 2 3 83.75 87.75 4 2 7 4 2 j 3 4 2 7 4 2' 3 91.75 95.75 4 2 7 4 2; 5 19,00 55.75 79.75 4 3 7 4 2 j 3 83.75 4 3 7 4 2 j 3 87.75 4 3 7 4 2 3 4 3 7 4 2 5 91.75 95.75 4 3 8 4 2 j 5 21.75 59.75 79.75 4 3 8 4 2 1 3 83.75 4 3 8 4 2; 3 87.75 4 3 8 4 2 j 5 5 3 8 4 2; 5 91.75 95.75 F 5 3 8 4 2 5 27.75 63.75 79.75 5 3 8 4 2 3 83.75 5 3 8 4 2 j 5 5 3 8 4 2 i 5 87.75 91.75 6 3 8 4 1 3 5 95.75 6 3 10 4 3; 5 36.13 67.75 79.75 6 4 8 4 3) 5 83.75 6 4 8 4 3 5 87.75 7 5 8 4 3 5 91.75 7 5 110 4 3 j 5 7 5 110 4 3 j 5 95.75 36.75 71.75 79.75 6 4 8 4 3; 5 6 4 9 4 3 i 5 83.75 7 5 9 87.75 7 5 10 4 3 5 91.75 95.75 7 5 110 4 3 5 ANCHOR QUANTITIES FOR THE DOOR AND SIDE LITE TO BE DETERMINED INDEPENDENTLY, 20-7/8" MAX. O.C. MAX, 6it MAX. B-B i 3 i 23-1/8" MAX. O.C. 84-3/8" MAX. DLO 36-3/4" MAX. SIDE LITE FRAME WIDTH HEAD -ZONE "E" 9" MAX. 9" MAX. A -A i I 3 I I II II \ (C 24 9/16\ MAX. DLO\ 3 71-3/4" MAX. DOOR FRAME WIDTH 143-3/4" MAX. DOOR +SIDE LITE FRAME WIDTH 9" MAX. 24-3/4" MAX. O.C. SEE TABLES 1-4, SHEET 2 FOR REINFORCEMENT REQUIREMENTS. 33-5/8" MAX DLO TYP. ELEVATION OF OXXO CONFIGURATION HEAD HEAD HEAD ZONE "F" ZONE "F" ZONE "E"� 911 MAXI MAX. �24-3/4" --� SILL 20-7/8 6" MAX. (-+-- OILL ZONE "E" SILL ZONE "F„ SILL ZONE "E" ZONE "F" LOAD ZONES FOR OXXO CONFIGURATION & ANCHORAGE LAYOUT USED IN EXAMPLE 95-3l4" MAX. FRAME HEIGHT Design Pressure Reinforced: See Sheet 2, Tables 1 & 2 Unreinforced: See Sheet 2, Tables 3 & 4 NOTES: 1) SEE SHEET 1 FOR GLASS AND ANCHOR TYPE DESCRIPTIONS. 2) DOORS MAY BE LEFT OR RIGHT-HANDED. 3) ANCHOR QUANTITIES ARE BASED ON SPACING AS FOLLOWS (4" MIN. O.C. FOR CONCRETE, 4" MIN, O.C. FOR CMU): JAMBS (ALL): 13-114" MAX. FROM CORNERS AND 23-1/8" MAX. O.C. HEAD & SILL OF DOORS: 6" MAX. FROM CORNERS, 9" MAX. FROM ASTRAGAL CENTERS AND 20-7/8" MAX. O.C. HEAD & SILL OF SIDE LITES: 6" MAX. FROM CORNERS AND 24-3/4" MAX. O.C. 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE, 5) FOR ANCHORAGE INSTALLAT{ON DETAILS SEE SHEETS 14 & 15. 6) CONFIGURATIONS WHERE THE DOOR LOCKSTILE ABUTS A SIDE LITE ARE NOT AVAILABLE WITH REINFORCEMENT. 7) SIDE LITE OVERLAPS DOOR BY 3/4" ONCE ASSEMBLED. EXAMPLE: OXXO WITH GLASS TYPE B, WIDE X 95-3/4" HIGH DOUBLE DOOR WITH (2) 36-3/4" X 95-3l4" SIDE LITES, ANCHOR TYPE 2 INTO CONCRETE, DESIGN PRESSURE = +34 / -34 PSF, SEE EXAMPLE 4, SHEET 2 FOR DP EXAMPLE DOOR ANCHOR REQUIREMENTS FROM TABLE i 1: 4 ANCHORS @EACH SIDE LITE JAMB 5 ANCHORS EACH DOOR PANEL @ HEAD 5 ANCHORS EACH DOOR PANEL @ SILL 3 ANCHORS EACH SIDE LITE @ HEAD 3 ANCHORS EACH SIDE LITE @ SILL OSEE CIRCLED VALUES ON TABLE 11. �( =DENOTES ANCHOR LOCATION. H) NO GRANGES THIS SHEET. - AK - 04/15/20 N Y = 0 naa 0 o O a}op af Lp C7 N o O Z o_ w r WU 0 FW-- UMOJp 'ON DMp t; > W IL 06 O � VIIIII O co O }aa4S ® N FIND z U J Z o Z 1- W Q aloas LL w I] w : O >r Q � a O al}il 'asap sauas �000 IIII ''��ceNs�oeI No. 58705 Q STATE OF 1(� F } r1VAl A. LYNN MILLER, P.E. P.E.# 58705 MAX. �24-3/4" --� SILL 20-7/8 6" MAX. (-+-- OILL ZONE "E" SILL ZONE "F„ SILL ZONE "E" ZONE "F" LOAD ZONES FOR OXXO CONFIGURATION & ANCHORAGE LAYOUT USED IN EXAMPLE 95-3l4" MAX. FRAME HEIGHT Design Pressure Reinforced: See Sheet 2, Tables 1 & 2 Unreinforced: See Sheet 2, Tables 3 & 4 NOTES: 1) SEE SHEET 1 FOR GLASS AND ANCHOR TYPE DESCRIPTIONS. 2) DOORS MAY BE LEFT OR RIGHT-HANDED. 3) ANCHOR QUANTITIES ARE BASED ON SPACING AS FOLLOWS (4" MIN. O.C. FOR CONCRETE, 4" MIN, O.C. FOR CMU): JAMBS (ALL): 13-114" MAX. FROM CORNERS AND 23-1/8" MAX. O.C. HEAD & SILL OF DOORS: 6" MAX. FROM CORNERS, 9" MAX. FROM ASTRAGAL CENTERS AND 20-7/8" MAX. O.C. HEAD & SILL OF SIDE LITES: 6" MAX. FROM CORNERS AND 24-3/4" MAX. O.C. 4) FOR SIZES NOT SHOWN, ROUND UP TO THE NEXT AVAILABLE SIZE, 5) FOR ANCHORAGE INSTALLAT{ON DETAILS SEE SHEETS 14 & 15. 6) CONFIGURATIONS WHERE THE DOOR LOCKSTILE ABUTS A SIDE LITE ARE NOT AVAILABLE WITH REINFORCEMENT. 7) SIDE LITE OVERLAPS DOOR BY 3/4" ONCE ASSEMBLED. EXAMPLE: OXXO WITH GLASS TYPE B, WIDE X 95-3/4" HIGH DOUBLE DOOR WITH (2) 36-3/4" X 95-3l4" SIDE LITES, ANCHOR TYPE 2 INTO CONCRETE, DESIGN PRESSURE = +34 / -34 PSF, SEE EXAMPLE 4, SHEET 2 FOR DP EXAMPLE DOOR ANCHOR REQUIREMENTS FROM TABLE i 1: 4 ANCHORS @EACH SIDE LITE JAMB 5 ANCHORS EACH DOOR PANEL @ HEAD 5 ANCHORS EACH DOOR PANEL @ SILL 3 ANCHORS EACH SIDE LITE @ HEAD 3 ANCHORS EACH SIDE LITE @ SILL OSEE CIRCLED VALUES ON TABLE 11. �( =DENOTES ANCHOR LOCATION. H) NO GRANGES THIS SHEET. - AK - 04/15/20 N Y = 0 naa 0 o O a}op af Lp C7 N o O Z o_ w r WU 0 FW-- UMOJp 'ON DMp t; > W IL 06 O � VIIIII O co O }aa4S ® N FIND z U J Z o Z 1- W Q aloas LL w I] w : O >r Q � a O al}il 'asap sauas �000 IIII ''��ceNs�oeI No. 58705 Q STATE OF 1(� F } r1VAl A. LYNN MILLER, P.E. P.E.# 58705 �000 IIII ''��ceNs�oeI No. 58705 Q STATE OF 1(� F } r1VAl A. LYNN MILLER, P.E. P.E.# 58705 EDGE DISTANCE 2X WOOD BUCK,NOTE1 DOOR HEAD (WOOD) EMBEDMENT 1/4" MAX. SHIM STAGGERED ,ANCHORS 2X WOOD BUCK, NOTE 1 1/4" MAX. SHIM DOOR JAMB (WOOD) SEE TABLE A, SHEET 1 EDGE DISTANCE /4" MAX. SHIM EMBEDMENT �2X WOOD EDGE DISTANCE BUCK, NOTE 1 DOOR SILL (WOOD) SEE TABLE A, SHEET 1 1X WOOD BUCK,NOTE 1 STAGGERED ANCHORS SEE TABLE A, SHEET 1 EDGE DISTANCE EMBEDMENT 1/4" MAX. SHIM SEE TABLE SHEET 1 DOOR HEAD (GONG) EMBEDMENT---�{ MAX. SHIM--i EDGE DISTANCE SEE A TABLE , SHEET 1 1X WOOD BUCK,NOTE1 DOOR JAMB (GONG) EE TABLE A, SHEET 1 ' EDGE DISTANCE DOOR SILL (GONG) EDGE DISTANCE SEE TABLE �A, SHEET 1 " MAX. SHIM SEE TABLE A, SHEET 1 DOOR HEAD (ALUMINUM) STAGGERE ANCHOR EDGE DIST :DGE DISTANCE A, SHEET 1 DOOR JAMB (ALUMINUM) SEE TABLE A, SHEET 1 4" MAX. SHIM SEE TABLE A, SHEET 1 DOOR SILL (ALUMINUM) 1. WOOD BUCKS DEPICTED AS 1x ARE LESS THAN 1 1/2" THICK. 1x WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE OR CMU. WOOD BUCKS DEPICTED AS 2x ARE 1 1/2" THICK OR GREATER. INSTALLATION TO THE SUBSTRATE OF WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION (AHJ). 2. IF SILL IS -TIGHT TO SUBSTRATE, GROUT OR OTHER MATERIAL IS NOT REQUIRED. IF USED, NON -SHRINK, NON-METALLIC GROUT (3350 PSI MIN.), (DONE BY OTHERS) MUST FULLY SUPPORT THE ENTIRE LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE, AND TRANSFER SHEAR LOAD TO SUBSTRATE. IF SUBSTRATE IS WOOD, 30# FELT PAPER OR MASTIC IS REQUIRED BETWEEN THE GROUT AND WOOD SUBSTRATE, OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. < EXTERIOR INTERIOR & TYP. ANCHOR TYPE, EMBEDMENT & EDGE DISTANCE PER SUBSTRATE, SEE TABLE A, SHEET 1.. (ALL HEAD & SILL SECTIONS) V H) NO CHANGES THIS SHEET. - AK - 04/15/20 N Y = naa L O U 0 o CAN O O o OI; ch Z w `- D LI,J c� U) �8 WU 0 u ojp 'ON T- w o � o I.L 06 O W O cfl O F¢•- }aa4s ® Lu Q � U Z O Z J aloos F- W �a u- Z � � o Q O al}LL losap sauas - �.�� ONE LYNN �IGEN& No. 58705 TFj_ ,4uTAT S/OAIAL I�N A. LYNN MILLER, P.E. P.E.# 58705 SEE TABLE EDGE DISTANCE EDGE DISTANCE 2X WOOD EDGE DISTANCE A, SHEET 1 BLICK, NOTE 1 - ^ SEE TABLE JA EMBEDMENT --- — — p �A, SHEET 1 1/4" MAX. SHIM SEE TABLE A, SHEET 1 SIDE LITE_HEAD (WOOD) EMBEDMENT 1/4" MAX. SHIM EDGE DISTANCE SEE TABLE A, SHEET 1 2X WOOD BUCK,NOTE1 SIDE LITE JAMB (WOOD) EDGE. TABLE A, SHEET 1 1/4" MAX. SHIM EMBEDMENT 2X WOOD BUCK, NOTE 1 SIDE LITE SILL (WOOD) 1X WOOD BUCK, NOTE 1 1/4" MAX. SHIM SEE TABLE A, SHEET 1 SIDE LITE HEAD (GONG) SEE TABLE A, SHEET 1 1/4" MAX. SHIM 1X WOOD BUCK, NOTE 1 EMBEDMENT EDGE DISTANCE e.. SEE TABLE A, SHEET 1 SIDE LITE JAMB (GONG) E TABLE A, SHEET 1 BUCK, NOTE 1 � 1/4" MAX. SHIM SEE TABLE - - A, SHEET 1 ,. • 4- ' EMBEDMENT �-►-I—EDGE DISTANCE SIDE LITE SELL (GONG) " MAX. SHIM SIDE LITE HEAD (ALUMINUM) SEE TABLE A, SHEET 1 =DGE DISTANCE :E TABLE SHEET 1 SIDE LITE JAMB (ALUMINUM) SHEET 1 /4" MAX. SHIM SEE TABLE A, SHEET 1 SIDE LITE SILL (ALUMINUM.) 1. WOOD BUCKS DEPICTED AS 1x ARE LESS THAN 1 1/2" THICK. 1x WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLY TO SOLID CONCRETE OR CMU. WOOD BUCKS DEPICTED AS 2xARE 1 1/2" THICK OR GREATER. INSTALLATION TO THE SUBSTRATE OF WOOD BUCKS TO BE ENGINEERED BY OTHERS OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION (AHJ). 2. IF SILL IS TIGHT TO SUBSTRATE, GROUT OR OTHER MATERIAL IS NOT REQUIRED. IF USED, NON -SHRINK, NON-METALLIC GROUT (3350 PSI MIN.), (DONE. BY OTHERS) MUST FULLY SUPPORT THE ENTIRE LENGTH OF THE SILL THAT IS NOT TIGHT TO THE SUBSTRATE, AND TRANSFER SHEAR LOAD TO SUBSTRATE. IF SUBSTRATE IS WOOD, 30# FELT PAPER OR MASTIC IS REQUIRED BETWEEN THE GROUT AND WOOD SUBSTRATE, OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. < EXTERIOR INTERIOR 3. TYP. ANCHOR TYPE, EMBEDMENT & EDGE DISTANCE PER SUBSTRATE, SEE TABLE A, SHEET 1.. (ALL HEAD & SILL SECTIONS) i Hj NO CHANGES THIS SHEET. - AK - 04/15/20 N Y 2 onab o O O c; e�OQ (� N O O o_ O�� Z w Xa U U D ap W FROM umo�d o N I— W T DMQ t? s Wto o n o � xs Q o WO `- (0 O #aa4S ® rn o —� (n N z O Z F w Z ammm, LL FW- U) CD J W Q Q ❑ aµLL asap sauaS \>>ti1 illll/ \,10EtN� _ No. 58705 y J� roo 2`� STATE OF !L ONAL A. LYNN MILLER, P.E. P.E.# 58705