HomeMy WebLinkAboutWINDOW-DOOR OPENING INFORMATIONVVINDQW &'DODR OFEN[NG INFORMAT QN A FLOOR PLAN WITH OPENING IDENTIFICATION SHOULD BE PROVIDED WITH THIS SHEET Definition of Comer Tone - 100/6 of least horizontal dimension or 40% of the mean roof heiaht. whichever is smaller_ but not less than 4% of least hnH7nn1a1 dimension nr a e OPENING LOCATION NUMBER (Location) Cotner Zone or Interior IS THIS A WINDOW OR DOOR GLAZING TYPE PRODUCT ACCEPTANCE NUMBER PRODUCT APPROVAL APPROVED PRESSURE RATING REQUIRED OPENING DESIGN PRESSURE MAXIMU M TESTEDOPENINGSHUTTERS SIZE ROUGH DIMENSIONS MULTIPLE WINDOW ARE REQ YIN {+) PSF {-) PSF (+) PSF {-) PSF MULLION REQ YININA 1 Int Window "$°iamilG FL23505.3 60 65 37.8 -41.0 54x76.5 23x6O YES No 2 Int Window 7B°Lam! lG FL23505.3 60 65 36.0 -39.2 54x76.5 49x60 YES No 3 Int Window 7I8" LamitG FL23505.3 60 65 37.8 -41.0 54 x 76.5 23x60 YES No 4 Int Window 718"Lam€ o FL23505.3 60 65 36.8 -40.0 54x76.5 36x61 YES No 5 End Window 7s°IamilG FL23505.3 60 65 36.8 -48.5 54x76.5 36x61 YES No 6 End Window 7/8""mi1G FL23505.3 60 65 36.8 -48.5 54x76.5 36x61 YES No 7 Int Window 78°LamiIG FL23505.3 60 65 36.8 -40.0 54x76.5 36x61 YES No 8 Int Window '"Am"o FL23505.3 60 65 37.8 -41.0 54 x 76.5 3406 No No 9 End Window "am" FL23505.3 60 65 37.8 -50.6 54 x 76.5 2506 No No 10 Int window 7"""Lami1G FL23505.3 60 65 37.8 -41.0 54x76.5 3607 No No