Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
DESIGN PRESSURE CALCULATIONS
PARAPM EXTER-JI-.-OORS "Building Our Quality Reputation One Customer At A Time" SCC131150472 Property Information Building Information Owner: TIMOTHY THAYER Wind Zone: 170 MPH, Address: 7008 LAKELAND BLVD Exposure Category: C FORT PIERCE, FL 34951 Minimum Building Dimension: 29 ft. Mean Roof Height: 12 ft. Risk Category: 11 Design Pressure Calculations Opening Numb or Locatiion� Zone Device Width (in) Device Height (in) Device va , EElevation (ft) JL—Pr—e Max Positive ssure (psj) 1p, Max Negative Pressure (pst) 1 Int 23 60 7 37.8 -41.0 2 int 49 60 7 36.0 -39.2 3 Int 23 60 7 37.8 -41.0 4 Int 36 61 7 36.8 -40.0 5 End 36 61 7 36.8 -48.5 6 End 36 61 7 36.8 -48.5 7 Int 36 61 7 36.8 -40.0 8 Int 34 36 7 37.8 -41.0 9 End 25 36 7 37.8 -50.6 10 Int 36 37 7 37.8 -41.0 Prepared in accordance with: ASCE 7-16, Chapter 30. WindLoads - Components and Cladding. 71h Edition (2020) Florida Building Code, Page 1 of I