HomeMy WebLinkAboutAPPROVED, PlansTITLE SHEETPREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONT-1DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637SITE NUMBER:280707SITE NAME:SANDS ON THE OCEANSTRUCTURE TYPE:ROOFTOPMARKET: JUPITERPROJECT TYPE: SUB-6280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21CONTACT INFORMATIONSITE DIRECTIONSLIST OF DRAWINGSLOCATION SKETCHAPPROVALSPROPERTY OWNER: _________________________________________________________________RF ENGINEER: ______________________________________________________________________CONSTRUCTION: ____________________________________________________________________SITE ACQUISITION: __________________________________________________________________ZONING: ___________________________________________________________________________NETWORK: _________________________________________________________________________OPERATIONS: ______________________________________________________________________SITE INFORMATIONSCOPE OF WORKPARCEL ID #:LATITUDE:LONGITUDE:1425-606-0083-000-327° 29' 25.8700" NORTH (NAD 83)80° 17' 54.7500" WEST (NAD 83)APPLICANT:VERIZON WIRELESS7701 E TELECOM PKWYTEMPLE TERRACE, FL 33637ARCHITECT/ ENGINEER:CBVR/ HUGH O. REILLY, PE6505 N HIMES AVETAMPA, FL 33614JURISDICTION:ST. LUCIETHE SCOPE OF WORK CONSISTS OF MODIFYING COMMUNICATIONSINSTALLATION ON AN EXISTING TOWER:EQUIPMENT PLATFORM:·REMOVE (1) 6120 CABINET·REMOVE (1) ELECTRICAL PANEL·INSTALL (1) CHARLES CUBE CABINET·INSTALL (1) 200A ILCTOWER RAD:·REMOVE (3) RRUS32 B4'S (1 PER SECTOR)·REMOVE (3) BIAS-T'S (1 PER SECTOR)·INSTALL NEW ANTENNA MOUNTS PER CBVR TELECOM STRUCTURALREPORT·INSTALL (3) VZE01 ANTENNAS (1 PER SECTOR)·INSTALL (3) RRU4449'S (1 PER SECTOR)·INSTALL (3) RRU8843'S (1 PER SECTOR)T-1TITLE SHEETSITE GENERAL ARRANGEMENT PLANSARCHITECTURAL/ CIVIL PLANSC-4EXISTING ANTENNA LAYOUTELECTRICAL PLANSC-2EQUIPMENT AREA PLANC-1ROOFTOP PLANE-1GROUNDING DETAILSC-6EQUIPMENT DETAILSC-3BUILDING ELEVATIONAPPLICABLE CODES- FLORIDA BUILDING CODE 2020 (7th EDITION)WIND DESIGN CRITERIAA. ASCE 7 - 16ULTIMATE WIND SPEED = 160 MPHRISK CATEGORY = IIEXPOSURE = DB. ANSI/ TIA-222-HSTRUCTURE CLASS = IITOPOGRAPHIC CATEGORY = 1-FLORIDA FIRE PREVENTION CODE - 2020 (7TH EDITION)-NATIONAL ELECTRIC CODE (NFPA 70-2017)-CITY AND OR COUNTY ORDINANCESE-2ELECTRICAL DETAILSFrom US-1 & FL-706 (Jupiter):1.Head northwest on US-1 N (go 62 ft)2.Use the left 2 lanes to turn left onto FL-706 W/E Indiantown Rd (go 3.8 mi)3.Continue straight onto W Indiantown Rd (go 0.2 mi)4.Slight right to merge onto I-95 N toward Daytona Bch (go 0.8 mi)5.Merge onto I-95 N (go 18.1 mi)6.Keep left to stay on I-95 N (go 25.3 mi)7.Take exit 131 to merge onto FL-68 E/Orange Ave (go 0.4 mi)8.Merge onto FL-68 E/Orange Ave (go 2.5 mi)9.Turn left onto FL-615 N/N 25th St (go 1.8 mi)10.Turn right onto Juanita Ave (go 0.9 mi)11.Turn right onto US-1 S (go 0.2 mi)12.Turn left onto Florida A1A S (go 2.5 mi)13.Turn left onto Florida A1A N (go 0.4 mi)14.Turn right (go 92 ft)15.Destination will be on the rightSITE LOCATIONBUILDING OWNER:SANDS ON THE OCEAN SECTION A ASSOCIATES3100 N A1AFORT PIERCE, FL 34949C-7PROPOSED ANTENNA & CABLE SCHEDULEC-5PROPOSED ANTENNA LAYOUT
AZ= SECTOR A335.00°AZ= SECTOR B185.00°AZ= SECTOR C260.00°PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-1DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21NOTE:1. ALL EXPOSED EQUIPMENT AND ANTENNAS TO BEPAINTED TO MATCH EXISTING BUILDING EXTERIOR.ROOFTOP PLANNOTES:·ALL DRAWINGS HAVE BEEN PREPAREDWITHOUT THE AID OF A SURVEY OR A TITLE·ALL DIMENSIONS, PROPERTY LINES, ANDRIGHT OF WAYS ARE APPROXIMATE BASEDUPON AVAILABLE ONLINE RESOURCES·CONTRACTOR SHALL RESTORE ANDREPAIR ANY DAMAGED AREAS CAUSED BYCONSTRUCTION TO ORIGINAL OR BETTERCONDITION·ALL NEW WORK TO BE PERFORMED PERLATEST VERIZON WIRELESS STANDARDS &SPECIFICATIONSROOFTOP PLANGRAPHIC SCALE11x17 SCALE: 1"=16'8'16'(SCALE IN FEET)0'EXISTING VERIZON WIRELESSEQUIPMENT PLATFORMEXISTING CABLE ROUTE TO SECTORS (REFER TO ANTENNASCHEDULE FOR EXISTING AND PROPOSED COAX/HYBRID COUNTS)EXISTING CARRIER ANTENNASON ROOFTOP MOUNTEXISTINGCROSSOVER LADDEREXISTING EQUIPMENTPLATFORMEXISTING CARRIER ANTENNASON ROOFTOP MOUNTEXISTING EXHAUSTFAN (TYP.)EXISTING VERIZONWIRELESS GAMMASECTOR ANTENNASEXISTING VERIZONWIRELESS ALPHASECTOR ANTENNASOUTLINE OFEXISTING BUILDINGEXISTING VERIZONWIRELESS BETASECTOR ANTENNASEXISTING DIESELGENERATOR ONCONCRETE PADEXISTINGCOOLING TOWERVERIZON WIRELESS EXISTING 50KW DIESELGENERATOR ON EXISTING CONCRETE PADEXISTIG VERIZONWIRELESS ATS AND MTSEXISTING CARRIERANTENNASEXISTING CARRIERANTENNASEXISTING CARRIEREQUIPMENT PLATFORMEXISTING CARRIERANTENNASEXISTING CARRIEREQUIPMENTSHELTEREXISTING CABLE TRAY
GG
GGPREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-2DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21EQUIPMENT AREA PLANEXISTING EQUIPMENT PLANPROPOSED EQUIPMENT PLAN2.5'5'11x17 SCALE: 1"=5'GRAPHIC SCALE(SCALE IN FEET)0'2.5'5'11x17 SCALE: 1"=5'GRAPHIC SCALE(SCALE IN FEET)0'1OVP-62DARK FIBER CABINET3EBRE BATTERY CABINET4FIBER JUNCTION BOX5FIBER BOX66120 LTE CABINET (TO BE REMOVED)7PPC (TO BE REMOVED)LEGENDNOTE:ALL EXISTING AND PROPOSED EQUIPMENT CONFIGURATIONSSHALL BE FIELD VERIFIED AND CONFIRMED BY GC WITH THEVERIZON WIRELESS CONSTRUCTION MANAGER.EXISTING GROUND CONNECTION TOEXISTING GROUND SYSTEM (TYP.)#2 AWG SOLID TINNED COPPER GROUNDCONNECTION, BOND TO EXISTING GROUNDSYSTEM (TYP. ON NEW EQUIPMENT)VERIZON WIRELESSEXISTING PLATFORMACCESS LADDEREXISTING CABLE ROUTE TO SECTORS (REFERTO ANTENNA SCHEDULE FOR EXISTING ANDPROPOSED COAX/HYBRID COUNTS)623EXISTING CABLE ROUTE TO SECTORS (REFERTO ANTENNA SCHEDULE FOR EXISTING ANDPROPOSED COAX/HYBRID COUNTS)11154VERIZON WIRELESSEXISTING PLATFORMACCESS LADDER6231115471OVP-62DARK FIBER CABINET3EBRE BATTERY CABINET4FIBER JUNCTION BOX5FIBER BOX6PROPOSED CHARLES CUBE CABINET7PROPOSED 200A ILCLEGEND7EXISTING VERIZON WIRELESSEQUIPMENT PLATFORMEXISTING ALPHA SECTOR FRAME(REFER TO ANTENNA LAYOUTS)EXISTING VERIZON WIRELESSEQUIPMENT PLATFORM
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-3DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21BUILDING ELEVATIONNOTES:1.CONTRACTOR TO FIELD VERIFY ANTENNA MOUNT CONFIGURATION AND PROVIDE MOUNTS OR ADDITIONAL HARDWARE IF REQUIRED TO SUPPORTPROPOSED EQUIPMENT.2.ALL EQUIPMENT AND MOUNTING HARDWARE SHALL CONFORM TO DESIGN REQUIREMENTS PER FLORIDA BUILDING CODE (7TH EDITION, 2020) AND ANSI/TIA-222-G STRUCTURAL STANDARD FOR ANTENNA SUPPORTING STRUCTURES AND ANTENNAS; ULTIMATE WIND SPEED 160 MPH, 3 SECOND GUST.3.ALL ANTENNAS, RADIOS, CABLING, AND ASSOCIATED MOUNTING HARDWARE SHALL BE PAINTED TO MATCH EXISTING BUILDING IN COLOR AND TEXTURE.ONLY THE PANEL OF THE VZE01 ANTENNA SHALL BE PAINTED AND NOT THE RADIO.4.AZIMUTH INFO TAKEN FROM VERIZON WIRELESS RF SITE DESIGN DATA. TOWER AND ANTENNAS HEIGHTS TAKEN FROM RECENT TOWER SURVEY DATA.5.REFER TO STRUCTURAL ANALYSIS REPORT BY CBVR TELECOM DATED 02/11/2021.BUILDING WEST ELEVATIONNOT TO SCALEEXISTING & PROPOSED VERIZONWIRELESS BETA SECTOR ANTENNASEXISTING ANTENNASON ROOFTOP MOUNTEXISTINGPENTHOUSEEXISTING ANTENNAS ONROOFTOP MOUNTEXISTING BUILDINGFAA NOTE:FAA APPROVED OVERALLHEIGHT = 167' AGLRAD CENTER OF EXISTING & PROPOSEDVERIZON WIRELESS ANTENNASEL. 143' AGLRAD CENTER OF EXISTING & PROPOSEDVERIZON WIRELESS ANTENNASEL. 147' AGLTOP OF PARAPET WALLEL. 136' AGLROOOFTOPEL. 133' AGLEXISTING GRADEEL. 0' AGLEXISTING AND PROPOSED VERIZONWIRELESS ALPHA SECTOR ANTENNASEXISTING VERIZON WIRELESSEQUIPMENT ON ROOFTOP PLATFORMEXISTING AND PROPOSED VERIZONWIRELESS GAMMA SECTOR ANTENNAS
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-4DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21EXISTING ANTENNA LAYOUTEXISTING ANTENNA MOUNT DETAILNOT TO SCALE1X7QCAP-665-VR0 ANTENNA2OVP-63RRUS32 (TO BE REMOVED)4BIAS'T (TO BE REMOVED)LEGENDNOTE:CONTRACTOR TO FIELD VERIFY ANTENNA MOUNTCONFIGURATION AND PROVIDE MOUNTS ORADDITIONAL HARDWARE PER MANUFACTURERRECOMMENDATIONS.AZ=
SECTOR B
185.00°11111122233443AZ= SECTOR A335.00°AZ= SECTOR C260.00°4EXISTING BUILDINGPARAPET WALLEXISTING BUILDINGPARAPET WALL
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-5DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21PROPOSED ANTENNA LAYOUTPROPOSED ANTENNA MOUNT DETAILNOT TO SCALENOTE:CONTRACTOR TO FIELD VERIFY ANTENNA MOUNTCONFIGURATION AND PROVIDE MOUNTS ORADDITIONAL HARDWARE PER MANUFACTURERRECOMMENDATIONS.AZ=
SECTOR B
185.00°111322244AZ= SECTOR A335.00°AZ= SECTOR C260.00°51X7QCAP-665-VR0 ANTENNA2OVP-63PROPOSED VZE01 ANTENNA4PROPOSED RRU44495PROPOSED RRU8843LEGEND3451NOTE:CONTRACTOR TO INSTALLANTENNAS TO MATCH MOST RECENTRFDS AND SHALL COORDINATE WITHCONSTRUCTION FIELD ENGINEERAND RF ENGINEER IF ADJUSTMENTSARE REQUIRED IN FIELD.5EXISTING BUILDINGPARAPET WALLEXISTING BUILDINGPARAPET WALL113
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-6DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637EQUIPMENT DETAILS280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21CUBE-SS4B228LX1 CABINET DETAILRADIO PIPE MOUNT DETAILPROPOSED MOUNT PIPE(ATTACHED TO WALL ORFRAME AS NECESSARY)PROPOSED POLE CLAMP ANDHARDWARE SUPPLIED WITHRRU. INSTALL PERMANUFACTURER'SSPECIFICATIONSPROPOSED RADIORADIO WALL MOUNT DETAILPROPOSED RADIOPROPOSED WALL RACKMOUNTING BRACKET.INSTALL PERMANUFACTURER'SSPECIFICATIONSPROPOSED MOUNTINGBRACKET AND HARDWARESUPPLIED WITH RRU. INSTALLPER MANUFACTURER'SSPECIFICATIONSRRU4449 DETAILRRU8843 DETAIL
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONC-7DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637PROPOSED ANTENNA &CABLE SCHEDULE280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21PROPOSED EQUIPMENT IN BOLD(*)REFER TO RFDSNOTES:1.VERIZON WIRELESS CURRENTLY HAS (12) 1-5/8" COAX AND (3) 6/12 HYBRID CABLES INSTALLED.2.LENGTH FOR PROPOSED HYBRID FIBER CABLE IS FROM VERIZON WIRELESS OVP AT EQUIPMENT TO VERIZON WIRELESS RAD CENTER.3.REQUEST CURRENT RFDS BEFORE INSTALLATION.4.ALL VERIZON WIRELESS ANTENNA AND CABLE DATA BASED ON ASSUMED ANTENNA HEIGHT, CONTRACTOR SHALL VERIFY PROPOSED ANTENNA HEIGHTPRIOR TO INITIATION OF CONSTRUCTION ACTIVITIES, INCLUDING, BUT NOT LIMITED TO, ORDERING OF ANY ANTENNA OR CABLE MOUNTING HARDWARE.
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONE-1DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21TO GROUND RINGPARALLEL EXOTHERMIC WELDSCALE : N.T.S.SCALE : N.T.S.SCALE : N.T.S.GROUNDING DETAILS1.DO NOT INSTALL CABLE GROUND KIT AT A BEND ANDALWAYS DIRECT GROUND WIRE DOWN TO GROUNDBAR2.GROUNDING KIT SHALL BE TYPE AND PART NUMBERAS SUPPLIED OR RECOMMENDED BY CABLEMANUFACTURER.3.WEATHERPROOFING SHALL BE TYPE AND PARTNUMBER AS SUPPLIED OR RECOMMENDED BY CABLEMANUFACTURER.4.BUTYL TAPE WEATHERPROOFING MUST FOLLOWMANUFACTURER'S INSTALLATION INSTRUCTIONS WITHTHE FOLLOWING MODIFICATION: ON THE FIRST TAPEPASS PROVIDE A COURTESY WRAP TO AVOIDPERMANENTLY ADHERING TO THE COAX CONNECTOR.5.START TAPE APPROXIMATELY 5 INCHES FROM THECONNECTOR AND WRAP 2 INCHES TOWARD THECONNECTOR, THEN REVERSE THE TAPE A HALF TURNOR SO THAT THE STICKY SIDE IS UP. CONTINUEWRAPPING THE TAPE OVER THE CONNECTOR UNTIL 3INCHES BEYOND THE CONNECTOR AND REVERSE THETAPE A HALF TURN AGAIN OR SO THAT THE STICKYSIDE IS DOWN FOR ANOTHER 2 INCHES.6.WHEN APPLIED, THE TAPE MUST BE ABOVE 32°F (0°C)TO ENSURE ADHESION7.DO NOT STRETCH THE TAPE AND DO NOT PULL THETAPE TO TEAR IT - ALWAYS CUT IT. PULLED TAPEEVENTUALLY UNRAVELS, DECREASING POSITION.8.TIGHTLY WRAP THE RUBBER TAPE WITH 2 LAYERS OFVINYL INSULATING TAPE.NOTES:WEATHERPROOFINGKIT (SEE NOTE 3)COAX CABLE GROUNDINGCLAMP KIT#6 AWG STRANDED CUWIRE WITH GREEN, 600V,THWN INSULATION(GROUNDED TO GROUNDBAR) (SEE NOTES 1 & 2)COAX CABLE TOANTENNA OR TMACOAX CABLE TOEQUIPMENT AT GRADENOTES:1.ALL HARDWARE 18-8 STAINLESS STEEL INCLUDING SPLIT WASHERS.2.COAT WIRE END WITH ANTI-OXIDATION COMPOUND PRIOR TO INSERTION INTO LUG BARREL AND CRIMPING.3.APPLY ANTI-OXIDATION COMPOUND BETWEEN ALL LUGS AND BUSS BARS PRIOR TO MATING AND BOLTING.TIN COATED-SOLID COPPER BUSSBAR PER SPECIFICATIONS2 HOLE, LONG BARREL TINNEDSOLID COPPER LUG (TYP.)NOTE: MINIMUM OF 3 THREADSTO BE VISIBLE (TYP.)S/S FLAT WASHER (TYP.)S/S NUT (TYP.)S/S SPLIT WASHER (TYP.)S/S FLATWASHER (TYP.)S/S BOLT (TYP.)CHERRY INSULATORINSTALLED IF REQUIREDPER SPECIFICATIONSSCALE : N.T.S.SCALE : N.T.S.NOTE:CONTRACTOR TO APPLYCOPPERSHIELD OR NO-OX3/8"x3/4" SS BOLT1/4"x4"x12" OR1/4"x4"x20" BUS BARSITE PRO 1PART #'SMG41236 (TYP.)MG42051 (MGB)3/8" LOCK WASHERINSULATOR PART # INS38-KOR APPROVED EQUIVALENT38" GALV. SCREWS2" AWG TINNED WIRELEAD W/ THERMOWELDMOUNTINGBRACKET PART#MT200 ORAPPROVEDEQUIVALENT3/8"x3/4" SS BOLTSS ANGLE ADAPTORPART# MG-ADAP-K ORAPPROVED EQUIVALENT(TOWER MOUNTING KIT)ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION OF THENATIONAL ELECTRICAL CODE (N.E.C.), AND APPLICABLE LOCAL CODES.GROUNDING SHALL COMPLY WITH ARTICLE 250 OF NATIONAL ELECTRICALCODE.ALL ELECTRICAL ITEMS SHALL BE U.L. APPROVED OR LISTED.ALL WIRES SHALL BE AWG MIN #12 THHN COPPER UNLESS NOTED.CONDUCTORS SHALL BE INSTALLED IN SCHEDULE 40 PVC CONDUIT UNLESSNOTED OTHERWISE.ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST ANDSTRAIGHTEST PATH POSSIBLE. BEND GROUNDING LEADS WITH A MINIMUM8" RADIUS.ENGAGE AN INDEPENDENT TESTING FIRM TO TEST AND VERIFY THATRESISTANCE DOES NOT EXCEED 5 OHMS TO GROUND. TEST GROUND RINGRESISTANCE PRIOR TO MAKING FINAL GROUND CONNECTIONS TOINFRASTRUCTURE AND EQUIPMENT. GROUNDING AND OTHER OPERATIONALTESTING SHALL BE WITNESSED BY VERIZON WIRELESSS REPRESENTATIVE.PROVIDE PULL BOXES AND JUNCTION BOXES WHERE REQUIRED SO THATCONDUIT BENDS DO NOT EXCEED 360°.OBTAIN PERMITS AND PAY FEES RELATED TO ELECTRICAL WORKPERFORMED ON THIS PROJECT. DELIVER COPIES OF ALL PERMITS TOVERIZON WIRELESS REPRESENTATIVE.SCHEDULE AND ATTEND INSPECTIONS RELATED TO ELECTRICAL WORKREQUIRED BY JURISDICTION HAVING AUTHORITY. CORRECT AND PAY FORANY WORK REQUIRED TO PASS ANY FAILED INSPECTION.REDLINED AS-BUILTS ARE TO BE DELIVERED TO VERIZON WIRELESSREPRESENTATIVE.ALL WORK SHALL BE PERFORMED IN STRICT ACCORDANCE WITH ALLAPPLICABLE BUILDING CODES AND LOCAL ORDINANCES, INSTALLED IN ANEAT MANNER, AND SHALL BE SUBJECT TO APPROVAL BY VERIZONWIRELESS REPRESENTATIVE.CONDUCT A PRE-CONSTRUCTION SITE VISIT AND VERIFY EXISTING SITECONDITIONS AFFECTING THIS WORK. REPORT ANY OMISSIONS ORDISCREPANCIES FOR CLARIFICATION PRIOR TO THE START OFCONSTRUCTION.PROTECT ADJACENT STRUCTURES AND FINISHES FROM DAMAGE. REPAIRTO ORIGINAL CONDITION ANY DAMAGED AREA.REMOVE DEBRIS ON A DAILY BASIS. DEBRIS NOT REMOVED IN A TIMELYFASHION WILL BE REMOVED BY OTHERS AND THE RESPONSIBLESUBCONTRACTOR SHALL BE CHARGED ACCORDINGLY. REMOVAL OF DEBRISSHALL BE COORDINATED WITH THE OWNER'S REPRESENTATIVE. DEBRISSHALL BE REMOVED FROM THE PROPERTY AND DISPOSED OF LEGALLY.UPON COMPLETION OF WORK, THE SITE SHALL BE CLEAN AND FREE OFDUST AND FINGERPRINTS.ELECTRICAL NOTES:GROUNDING NOTES:ALL DOWN GROUND WIRE AND GROUND SYSTEM WIRE SHALL BE #2 AWG, SOLID,BARE, TINNED COPPER. ALL CONNECTIONS TO GROUND SYSTEM SHALL BEEXOTHERMICALLY WELDED.WHERE MECHANICAL GROUNDING CONNECTIONS ARE SPECIFIED, BOLTED,COMPRESSION-TYPE CLAMPS OR SPLIT-BOLT TYPE CONNECTORS SHALL BE USED.GRIND OFF GALVANIZING IN AFFECTED AREA. EXOTHERMICALLY WELD #2CONDUCTOR. COLD-GALV AFTER. EXOTHERMICALLY WELD OTHER END TOGROUND.FOLLOWING COMPLETION OF WORK, CONDUCT GROUND TEST. SUBMIT WRITTENTEST TO CONSTRUCTION MANAGER AND PROJECT MANAGER.ALL GROUNDING WORK SHALL COMPLY WITH VERIZON WIRELESS STANDARDS.UNLESS NOTED OTHERWISE, ALL GROUNDING SHALL BE IN ACCORDANCE WITHVERIZON WIRELESS'S REQUIREMENTS FOR "BONDING, GROUNDING ANDTRANSIENT PROTECTION FOR CELL SITES", AND "SITE RESISTANCE TO EARTHTESTING". ALL GROUNDING SHALL ALSO COMPLY WITH ALL STATE AND LOCALCODES, AND THE NATIONAL ELECTRICAL CODE (NEC).UNLESS NOTED OTHERWISE, ALL GROUNDING CONNECTIONS SHALL BE MADE BYAN EXOTHERMIC WELD.RESISTANCE TO EARTH TESTING IS REQUIRED PER NEC STANDARDS ON ALL NEWSITES.NEW INSTALLED ANTENNA PIPE MOUNTS SHALL BE EXOTHERMICAL GROUNDED W/#2 AWG SOLID TINNED COPPER TO EXISTING GROUND SYSTEM (EACH SECTOR).ALL NEW COAX OR HYBRID CABLES SHALL BE GROUNDED W/ SUPPLIED GROUNDKIT TO SECTOR GROUND SYSTEM.EXTERIOR GROUND RING. #2SOLID BARE TINNED COPPERGROUNDING CONDUCTORNO SLAG ORDEFORMITIES ALLOWEDEXOTHERMIC WELD(THERMOWELD OREQUIVALENT) PARALLEL, NOT-WELD ALLOWED.MIN. TURNINGRADIUS 45° (TYP.)JUMPER. #2 SOLID BARETINNED COPPERGROUNDING CONDUCTORGROUNDING BAR LUG DETAILSCOAX CABLE GROUNDTYPICAL GROUND BAR DETAILTYP. METALLIC GROUNDING DETAILEXOTHERMIC WELD DETAILMETALLIC BOX, HOUSING ETC.#2 AWG BARE TINNED SOLIDCOPPER WIRE (UNIT BOND)BRASS TWO HOLEMECHANICAL CONNECTORWITH STAINLESS HARDWARE
PREPARED BYPROFESSIONAL SEALISSUED DATESSHEET NAMESHEET NUMBERPREPARED FORPROJECT INFORMATIONE-2DISCLAIMER:NO COPIES, REPRODUCTIONS, TRANSMISSIONS OR ELECTRONIC MANIPULATIONOF ANY PORTION OF THESE DRAWINGS IN WHOLE OR IN PART ARE TO BE MADEWITHOUT THE EXPRESS WRITTEN PERMISSION OF CBVR TELECOM DESIGNGROUP. ALL DESIGNS INDICATED IN THESE DRAWINGS ARE PROPERTY OF CBVRTELECOM DESIGN GROUP. ALL COPYRIGHTS RESERVED (C) 2021. THESE PLANSARE FOR BUILDING DEPARTMENT REVIEW ONLY THEY ARE NOT TO BECONSTRUED AS CONSTRUCTION DOCUMENTS UNTIL ALL BUILDING DEPARTMENTAPPROVALS ARE OBTAINED.6505 N HIMES AVETAMPA, FLORIDA 33614(770) 853-1233FL CA # 3101403/29/20217701 E TELECOM PKWYTEMPLE TERRACE, FL 33637280707SANDS ON THE OCEAN3100 NORTH A1A SANDS ON THEOCEAN SECTION 1 - CONDOFORT PIERCE, FL 34949CBVR PROJECT #: VZW.119.20ISSUED FOR PERMIT003.29.21ELECTRICAL DETAILSELECTRICAL DETAILS200A ILCNEL200AINTEGRATEDLOADCENTERC200APRIMARYCABINETGFCIRECPT.LIGHT2-#12 AWG1-#12 AWG EG1" CONDUITBAH CAB.12-#6 AWG (6 PAIRS)#6 AWG EG 1-1/2"LMFC1" CONDUIT FOR GEN & ILC ALARMSELECTRICAL SINGLE LINE DIAGRAM(P) VERIZON WIRELESS ILCCABINET WITH 2P/200AUTILITY BREAKER ANDOPTIONAL 2P/200A CAMLOCK BREAKERMECHANICALLYINTERLOCKED WITHWALKING BEAM TRANSFERSWITCH AND 30 POSITIONLOAD CENTERCAM LOCK(OPTIONAL)3-#3/0 AWG#6 AWG EG2" CONDUITUL LISTED8-#10 AWG, 1-#10 AWG EG (RECTIFIERCONDUCTORS SHALL BE RATED THHN ORHIGHER) IN (1) 1-1/2" CONDUIT. ROUTECONDUIT ABOVE GROUND SECURED TOEQUIPMENT FRAMESECONDARYCABINET6-#10 AWG, 1-#10 EG IN (1)1-1/2" CO. FOR FUTURE REC.2-#12 AWG1-#12 AWG1" CONDUITEXISTING CONDUIT TO EXISTINGVERIZON WIRELESS POWER SOURCENOTE:THE EXISTING AC POWER ELECTRICAL SYSTEM SHALL REMAINUNCHANGED. DC POWER SHALL BE DISTRIBUTED FROM THEEXISTING RECTIFIERS IN PROPOSED CHARLES CUBE CABINET.FIBER SHALL BE DISTRIBUTED FROM EXISTING FIBER ROUTERSIN EXISTING CABINETS. THERE SHALL BE NO CHANGES ORINCREASES IN AC POWER LOAD, AND PREVIOUSLY DESIGNED,PERMITTED, APPROVED, AND INSTALLED ELECTRICAL SYSTEMSHALL REMAIN AS IS IN CURRENT CONDITION. REFER TOSHEET E-2 FOR AC ELECTRICAL DETAILS.2P-200AMP50KWGEN3-#3/0 AWG6 AWG EG2" CONDUIT1" CONDUIT FOR GEN CONTROLS & ALARMS4-#12 AWG,1-#12 AWG EG,1" CONDUIT (FOR GEN HEATER & BATT. CHARGER)NOTE: THE GENERATOR USED INCONJUNCTION WITH A 2-POLE ILCWITH A SOLID NEUTRAL IS NOT ASEPARATELY DERIVED SYSTEM.AS SUCH, DO NOT BOND THENEUTRAL TO GROUND AT THEGENERATORGEN MAINDISCONNECT/FUSED SWITCHPANEL SCHEDULEUSAGEFACTOR135791113151719212325272924681012141618202224262830BUS AMPSPOSL2L1LOADPOLESAMPSL2L1USAGEFACTORBUS AMPSPOSL1L2LOADPOLESAMPSENCLOSURETYPE:MOUNT:MAINBREAKER:RATEDVOLTAGE:PANELNAME:240120VOLTSVZW ILCSURFACE200NEMA 3RAMPSAIC:NEUTRALBAR:BUSRATING:PHASE/WIRE:MODELNUMBER:KEY DOORLATCH:HENGED DOOR:YESYES13200YES65KASCO D300L SERIESFACTORED TOTALAMPSFACTORED SUBTOTAL AMPSFACTORED SUBTOTAL AMPSRECTIFIERRECTIFIERRECTIFIERRECTIFIERFUTURERECTIFIERFUTURERECTIFIER181818181818181818181818GFI RECEPT.BLOCK HEATERBATT. CHARGER612585.75874036125.75123NOTES:1.ALL CONDUCTORS ARE TYPE THWN (75°C) COPPER, UNLESS NOTED OTHERWISE.2.MAXIMUM LENGTH OF RUN FOR RECTIFIER CIRCUITS IS 50FT.3.ASCO INTEGRATED LOAD CENTER INCLUDES 200 AMP MAIN DISCONNECT AND TRANSFER SWITCH FOR PORTABLE OR PERMANENTGENERATOR.4.RECTIFIER LOADS ARE CONSIDERED TO BE NON-CONTINUOUS, BLOCK HEATER AND BATTERY CHARGER ARE INACTIVE WHILE GENERATORIS IN USE.5.IF ADDITIONAL FUTURE LOADS ARE ADDED WHICH CAUSE TOTAL DEMAND TO EXCEED GENERATOR BREAKER SIZE, BACKUP POWERSYSTEM SHALL BE EVALUATED AND UPGRADED AS NECESSARY.PROPOSED LOAD:LOAD CALCULATIONLOADAMPSVOLTAGE: 120/240V SINGLE PHASE 3W 200A125.75TOTAL DEMAND:125.75230A230A230A230A230A230A120A120A120A111111111.251.251.251111120A1SERVICE LIGHT4(E) 300 GALDIESEL TANK(E) VERIZON WIRELESS 50KW120/240 V, DIESEL GENERATORWITH 200A MAIN BREAKER.GENERATOR IS IN A NEMA 3RENCLOSURE. SUPPLIED WITH1500W 120V BLOCK HEATER.NOTES:1.ALL EQUIPMENT SHALL BE NEMA 3R RATED.2.ALL EQUIPMENT SHALL BE LIGHTNING PROTECTED IN ACCORDANCE WITH TIA-222-H AND VERIZON WIRELESS STANDARDS.3.BELOW GRADE CONDUIT SHALL BE SCHEDULE 80 PVC. ABOVE GRADE CONDUIT SHALL BE GALVANIZED RIGID CONDUIT. BELOW GRADE PVC CONDUIT SHALL TRANSITION TO GRCPRIOR TO RISING ABOVE GRADE. ALL BENDS SHALL HAVE A MINIMUM 24" RADIUS. ALL FITTINGS SHALL BE SUITABLE FOR USE WITH THREADED RIGID CONDUIT. VERIFY CONDUITTYPE WITH LOCAL CONSTRUCTION MANAGER AND ADJUST IF NECESSARY. ALL CONDUIT SHALL MEET NEC, STATE, AND LOCAL CODE REQUIREMENTS AS REQUIRED.4.DIAGRAM SHOWN FOR TYPICAL CONFIGURATION. VERIFY ALL EQUIPMENT, BREAKERS, CONDUIT, AND CONDUCTORS WITH FIELD CONSTRUCTION MANAGER PRIOR TOCONSTRUCTION.