HomeMy WebLinkAboutProduct Approval; Metal Roofingr.
a j
,i
a I
s
BCIS Home } Log In ,{ User Registration Hot Topics a Submit Surcharge Stats & Facts } Publications ;; Contact us BCIS Site Map Unks - Search
b
a .:. ..
IProductApproval
USER: Public User
011 uo
Product Aoorovat Menu > Product or AOpjL_ ion Seartli > AppJlcatlon Ust > Application Detail n [ RECEIVE
'0 FL # FL27499-R3
�JUN 1 2029
" Application Type Revision f
Code Version 2020 ,
Application Status Approved mil. !� - l C ®w� k Lucie; County, Permitting
Comments
Archived
Product Manufacturer Dynamic Metals
Address/Phone/Email 3201 SE Dominica Terace
Stuart, FL 34997
(772)872-8030
juan@dynamicmetal.net
Authorized Signature Lara Jesus
juan@dynamlcmeta1.net
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
FILE COPY
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Scott Wolters
Evaluation Report
Florida License PE-62354
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/06/2026
Validated By Lucas A. Turner, P.E., MBA
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL27499 R3 COI Dyn C01pdf
Standard
Year
TAS 100
1995
TAS 110
2000
TAS 125
2003
Product Approval Method Method 1 Option D
Date Submitted
12/17/2020
Date Validated
12/19/2020
Date Pending FBC Approval
12/26/2020
Date Approved
02/09/2021
Date Revised
04/18/2021
Summary of Products
Go to Page V 0 Page 1/ 24 0
FL #
Model, Number or Name
Description
27499.1
DM Class 1000 1" Nailstrip
26 Ga. galvalume coated steel roof panel, 16" wide, with 1"
snap fit seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II NSSI6HZ.odf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R3 AE DM Evall.Zdf
Created by Independent Third Party: Yes
27499.2
DM Class 1000 1" Nailstrip,
.032" Aluminum roof panel, 16" wide, with 1" snap fit seams.
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
FL27499 93, II NSAI6HZ.adf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eva[ report for Limits of Use.
FL27499 R3 AE DM Eval2.pdf
Created by Independent Third Party: Yes
27499.3
DM Class 1050 1 1/2" Nailstrip
.032" Aluminum Roof Panel, 19" Wide, with 1 1/2" snap fit
seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 -II NSAI9HZ.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R3 AE DM Eval3.odf
Created by Independent Third Party: Yes
27499.4
DM Class 1050 1 1/2" Nailstrip
24 Ga. Galvalume coated steel roof panel, 19" wide, with 1
1/2" snap fit seams
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II NSSI9HZ.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R3 AE DM Eval4.odf
Created by Independent Third Party: Yes
27499.5 DM Class 1150 1" Mechanical Seam .03V Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R3 1I DM Dwo52.odf
Approved for use outside HVHZ: Yes Verified By: Scott Walters FLPE# 62394
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other. Please see Eval Report for Limits of Use. FL27499 R3 AE DM Eval52.pdf
Created by Independent Third Party: Yes
27499.6
DM Class 1150 1" Mechanical Seam
.032" Aluminum roof panel, 21" wide, with 1" standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL27499 R3 11 OM Dwo62.odf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters FLPE# 62394
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Please see Installation Drawings and Eval Report for
FL27499 R3 AE DM Eval62.pdf_
Limits of Use.
Created by Independent Third Party: Yes
27499.7 I DM Class 1150 1" Mechanical Seam 126 Ga. Galvalume coated steel roof panel, 21" wide, with 1"
standing seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes F427499 R3 II DM Dwg72.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters FLPE# 62394
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Installation Drawings and Eval Report for FL27499 R3 AE DM Evaf72.pdf
Limits of Use. Created by Independent Third Party: Yes
27499.8 DM Class 1500 1 1/2" Mechanical I .032" Aluminum roof.panel, 20" wide, with 1 1/2" standing
Seam seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R3 II 1SMSA20HZ.pdlf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eva[ report for Limits of Use. FL27499 R3 AE DM Eva18.pdf.
Created by Independent Third Party: Yes
27499.9 I DM Class 1500 1 1/2" Mechanical 116 oz. Copper roof panel, 16" wide, with 1 1/2" standing
Seam seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R3 II 15MSCHZ.odf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other. Please see Eval report for Limits of Use: FL27499 R3 AE DM Eval9.pdf
Created by Independent Third Party: Yes
27499.10 DM Class 1500 1 1/2" Mechanical 126 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2"
Seam standing seams.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R3 II 1SMSS1626HZ:pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eva[ report for Limits of Use. FL27499 R1 AE DM Evall0.pdf
Created by Independent Third Party: Yes
27499.11 I DM Class 1500 1 1/2" Mechanical 032" Aluminum roof panel, 16" wide, with 1 1/2" standing Seam I
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R3 II -15MSA16HZ.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 P?-AE:DM.Eya)l .pdf`
`Created' by Independent Third Party: Yes
27499.12 I DM Class 1500 1 1/2" Mechanical 124 Ga. galvalume coated steel roof panel, 16" wide, with 1 1/2"
Seam standing seams.
Limits of Use Installation Instructions
Approved for use in. HVHZ: Yes FL27499 R3 II 15MSS16HZ.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use. FL27499 R3 AE. DM Eval12.pdf
Created by Independent Third Party: Yes
27499.13
DM Class 1500 1 1/2" Mechanical
Seam,
24 Ga. galvalume coated steel roof panel, 20" wide, with 1 1/2"
standing seams.
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II 15MSS20HZ.pdf
Approved for use outside HVHZ: Yes
Verified By: Scott Wolters 62354
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports,
Other: Please see Eval report for Limits of Use.
FL27499 R3 AE DM Eval13.odf
Created by Independent Third Party: Yes
27499.14 DM Class 1750 1 3/4" Snaplock 24 Ga. Galvalume coated steel roof panel, 18" wide, with 1
3/4" Snaplock seams, attached to metal deck.
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27499 R3 II SLS18BDHZ.pdf
Approved for use outside HVHZ: Yes Verified By: Scott Wolters, P.E. FLPE# 62354
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other: Please see Eval report for Limits of Use.
FL27499 R3 AE 'DM Eva114.Ddf
Created by Independent Third Party: Yes
27499.15
DM Class 1750 1 3/4" Snaplock
.032" Aluminum roof panel, 18" wide, with 1 3/4" Snaplock
seams, attached to metal deck.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499 R3 II SLA1813DHZ.Dd
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R3 AE DM Eval15.pdf
Created by Independent Third Party. Yes
27499.16
DM Class 1750 1 3/4" Snaplock
.032" aluminum roof panel, 18" wide, with 1 3/4" Snaplock
seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499 R3 II SLA18HZ.Ddf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R3 AE DM EvaI16.Ddf
Created by Independent Third Party: Yes
27499.17
DM Class 1750 1 3/4" Snaplock
24 Ga. galvalume coated steel roof panel, 18" wide, with 1 3/4"
Snaplock seams.
Limits. of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report far Limits of Use.
Installation Instructions
FL27499 R3 II SLSI8HZ.Ddf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 'R3 AE QM Evall7.pdf
Created by Independent Third Party: Yes
27499.18
DM Class 2000 2" Mechanical Seam
.032 Aluminum roof panel, 18" wide, with 2" standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499 R3 II 2MSA18HZ.pdf
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R3 AE DM EvalMgdf
Created by Independent Third Party: Yes
27499.19
DM Class 2000 2" Mechanical Seam
24 Ga. galvalume coated steel roof panel, 18" wide, with 2"
standing seams.
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Installation Instructions
FL27499 R3 II 2MS518HZ.Ddf
Verified By; Scott Wolters 62354
Created by Independent Third Party: Yes
Evaluation Reports
FL27499 R3 AE 'DM Eva119.Dd
Created by Independent Third Party: Yes
499.2D ="'D
Glass 500 5V _rimp
26- aa.. galvalu'rrte eoated'steei roo panei;'24" wide, with 5V
1pl
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL27499 R3 II OM DwQO pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Scott Wolters 62354
Created by Independent Third Party: Yes
Design Pressure: N/A
Other: Please see Eval report for Limits of Use.
Evaluation Reports
FL27499 R3 AE DM Eval20,pdf
Created by Independent Third Party: Yes
Go to Page
Back Next
Contact Us:: 2601 Blair Stone Road, Tallahassee Fl. 32399 Phone: 850-487-182a
,400'Page 1/2100
The State of Florida is an AA/EEO employer. Privacy Statement :: Accessibility Statement :: Refund Stateme
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, KS: must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click !ere .
Product Approval Accepts:
Ir- "TH m 10 F-
Ve-dW.Card
OLTES ENGINEERING
ENGINEERING, DRAFTING, CONSULTING
1521197th Road N
West Palm Beach, FL 33412
Ph/Fx: (561) 225-1982
;PRODUCT EVALUATION
TORt HVHZ APPROVED PRODUCT)
PRODUCT: DM CLASS 500 26-GA. GALVAL'UME 5V CRIMP- 24" WIDE
ROOF PAWEL (FLPA# 27499.20)
MANUFACTURER: DYNAMIC METALS., LLC
340 PIKE ROAD
WEST PALM BEACH, FL 33411
To all concerned,
The DM ClassZ00 Series 26 Ga. Galvalume:5V Crimp 24" Wide Roof Panel, manufactured by Dynamic
Metals LLC, is a non-structural galvalume.coated `Fluropon painted steel roof panel (50 ksi min) that meets the
requirements of Sections 1507A and 1518.9 of the 7th Edition (2020) Florida Building Code. The panel has been
tested per TAS 100 and TAS 125 by Intertek.with results shown in test reports G3443.38-450-44 and H2686.02-
450-44, and per TAS 110 by PRI Construction Materials Technologies, with "results shown in test reports. VLS-004-
02-01 and VLS-005-02=01,
Technical Documentation:
1� 'Drawing "5VS-HZ" dated 8115/19, signed and sealed by Scott Wolters, PE.
2. Test Reports;listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE.
3. Test'Reports-listed above by PRI Construction Materials Technologies, signed and sealed by Zachary
R Priest, PE.
4. Supplemental Calculationsto support "5VS-HZ" drawing, signed and sealed by Scott Wolters, PE.
I have reviewed this submittal per the requirements of FAG Product Approval Rule Chapter 61 G20-3.005
(4). Based on the limitations listed below and those provided in the documents above, this product meets all the
requirements_of the 7th-Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the
HVHZ provisions.
Limitations: This panel Is approved for use inside and outside of the HVHZ.
Overall Limitations: Maximum Panel Width: 24" (nominal)
Fastener Spacing across panel: 12" (at Overlaps & Center Rib)
Min, Slope: HVHZ: 2"112"
Non-HVHZ: Y2712" (with Lap Sealant)
3712" (no Lap Sealant)
5MCJA1,IZI:.% IN IMPACT P.8515TAW CL510%TF0Vr5., & Wi'V(?11r
Field
Installation
Perimeter & Comer
Installation
Max. Design, Pressure:
117.75"sf
-206 Of
Fastener Spacing:' .. ,
4" From Ends,16" Max,'O.C.
4" From Ends, 8".Max. O.C.
Min.Panel Fasteners,
#10x1 W HiLo HWH Screw
with Weather=seal- Washer
#10x1 %' HiLo HWH Screw
with Weather -seal Washer
Fire :Barrier: Where required by code, install an approved fire barrier, Refer to a current
fire directory listing for fire ratings -of this roofing system assembly as well
as the location of theft barrier within the assembly. (See note #2 below)
Note: Outside of the HVHZ,1 round plastic caps. meeting the requirements of
FBC Section 1507,1 J,1, may be used to prevent,galvanic reactions.
Undetlayment: Minimum ASTM D 226 Type 11, installed and anchored per FBC Section
1507.1,1.1(min).'
(or)
Any undedayment with a valid FLPA or Miami -Dade NOA
Note: Outside of the HVHZ, 10 round plastic caps meeting the requirements of
FBC Section 1507.1.1.1 may be used to prevent galvanic reactions.
Minimum Substrate: % (15/32" min) 4-ply CDX Plywood or %" solid wood planks S.G. = .42
min. nailed to 2x rafters .spaced 24" max. on center with 8d ring -shank
nails spaced 6" on center.
Note: The %d' wood planking must be installed as a solid deck and must be
nailed or fastened in a manner equal to the deck above, or as specified by
a Florida licensed Architect/Engineer
Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or
1515.2.
2. `Fire classification is not a part of this evaluation. Refer to a current
Approved Roofing Materials Directory for fire ratings of this product.
3. Design of substrate isby others and is not a part of this evaluation.
`1'i-ICIZIN6IN I1W_t1T1rIr-6[ NfUf9NAI -1,55, 8 WINVOW5
4. Rational analysis, provided by a Florida licensed ArchitecUEngineer
per FAS 61 G20.3.005(e), may be used for project specific approval by
the local authorities'having jurisdiction.
5. Where required by the Florida Building Code, panels shall be
permanently labeled with the manufacturer's name and/or logo, and the
following :statement, "Dynamic Metals FL #2749920, DM Class 500".
Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per
approval of 31d party QA provider;`to the dimensions shown oil Drawing 5VS-HZ:
SSQ-6800617 SSQ-5150216 SSQ=681.0617
SSQ-6690517 SSQ-4560615 SSQ2-2310920
5VU490718 5VC-0360516 SSQ2-2320920
Re -Roofing: The DM Class '500 Series 26 Ga. Galvalume 5V Crimp 24" Wide Roof Panel
maybe installed over a single layer of existing asphalt shingles, provide the existing roof
meets the requirements of Section 1511 of the Florida Building Code.
If you have any questions or need' more information concerning this approval, please contact me.
Thank you,
�ti. • •j ,�J ' rf
•��C�NS���S`'.
dw *. No .62354
cott o ers�
FL PE# 62354',
STATE i
CCt23 020
OF 41Y
•-
(JP.
`�'"Ft�i��.IZING IN its"�';?��1 f?�4?fa'Jr CU,'.•r;?INVVh�.l.5. �1OF?F�'�C�IJ'�, & VJIN�Qd"v5
I
DM GLASS-500. 5V_ CRIMP 24 M DE
26-GA GAL VALUME-ROOVPANEL (HVHZ-)
joinel OroffW