HomeMy WebLinkAboutWind Pressure Chart&AD/NG'S PEAK ROOF HEIGHT m DESIGN WIND PRESSURE FOR COMPONENTS CLADDING (P S F) FOR ASCE 7-16 OF HEIGHT LESS THAN OR EQUAL TO 60 FEET aK BASIC WIND SPEED = 170 mph RISK CATEGORY II BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF I- LESS THAN 7'-9" Lxx GREATER OR EQUAL THAN 7'-9" AND LESS THAN 12'-3" Lsx GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE A.S.D. 0' - 15, 76.4 45.8 102.4 61.4 - 73.0 43.8 95.5 573 68.5 41.1 86.4 51.8 > 15'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90: 8 54.5 > 20'-25' 83.6 50.2 111.9 67.1 79.8 47.9 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3. 46.4 97.4 58.4 > 30'-40' 90.7 54.4 121.4 72.8 86.6 52.0 113.3 68.0 81.2 48.7 102.4 61.4 > 40`-50' 94.3 56.6 126.2 75.7 90.0 54.0 117.7 70.6 84.4 50.6 106.5 63.9 > 50'-60' 9.7.3 58.4 130.3 78.2 92.9 55.7 121.5 72.9 87.2 52.3 109.9 .65.9 BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS A CLADDING (P Sy) FOR ASCE 7 16 PEAK ROOF HEIGHT GREATER THAN 60 FEET aK BASIC WIND SPEED 170 mph RISK CATEGORY I/ BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) PEAK ROOF Lxx LESS THAN 12-3" Lxx GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULT/MAT£ A.S.D.. ULTIMATE' A.S.D. > 60' - 70' 91.5 54.9 16Z 7 100. 6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56 2 171.E r103Q 86.2 �51 151.9 ► `911 80' - 90' 95.6 57.4 175.2 105.1 88.6 52.8 155.0 93.0 > 90' - 100' 973 58.4 178.4 107.4 89.7 53.8 157.9 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 163.0 97.8 > 120' - 140' 103.2 61.9 189.2 113.5 95.1 57.1 167.4 100.4 > 140' - 160' 105.6 63.4 193.6 116.2 97.3 58.4 171.3 102.8 > 16o' - 18o' 107.8 64.7 197.6 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 106.9 > 200' - 250' 114.1 68.5 209.2 125.5 105.2 63.1 185.1 111.1 > 250' - 300' 1178 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300' - 350' 121.0 72.6 221:9 133.1 111.5 66.9 196.3 117.8 > 350' - 400' 123.9 74.3 22 7. 1 136.3 114.1 68.5 200.9 120.5 > 400' - 450' 126.4 75.8. 231.8 139.1 1 116.5 69.9 05.1 123.1 > 450'. - .500' 128.8 77,3 .... 236. 1 141.7 1 118.6 71.2 208.9 125.3 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS, ENGINEER, BASED ON ASCE 7-16, FOR A BASIC WIND SPEED .OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES, IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.)THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER IF USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND A.S.D. PRESSURES 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY • MEANS. 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.g., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET ETC.). * INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. * L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BAHAMA SHUTTER HEIGHT. * * PRODUCTS WHICH BEAR A MIAMI-DADE COUNTY OR A STATE OF FLORIDA APPROVAL PR0 �l No.44167 STATE OF 2020 (7th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER COUNTIES