Loading...
HomeMy WebLinkAboutBOUNDARY SURVEY0 LEGAL DESCRIPTION: (Supplied by Client) LOT 183, WATERSTONE PHASE 3, ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 91, PAGES 21 THROUGH 31, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. O = S T 51$ IRON REBAR 1hN YELL OJ CA PP ARKED "PSM5 3" FD = FOUND 5/8 IRON REBAR RWf= IyI=IGHT OF EASURED WAY P) = PLATTED C = CALCULATED = RADIUS OF CURVE L = LE OF CURVE D= DELTA OF CURVE FFE = FINIS ED FLOOR ELEVATION OH -OH -OH- = OVERHEAD I RES X-X-X- = CHAINLINK FENCE -E - LASTIC FENCE 0-0-0- = WOOD FENCE CONC. = CONCRETE C.P. = CON RETE PAD Coy.=V� COVERED ER MELEC ETE POLTE ER� BOX TRIC LIGHT SEWER CLEAN POLE VALVE O Ill IT FD NAIL DISK p "LB 5610" I i IZZ IM 25.00' o O a O L,_I tO � c_j ~ L�J � 1 i/) C Q O N � IL In LLJ Cl- NI O CV LLLJ o of o, �_ (n tLO aN 25.00' . Cr M 10 M� =*m 1� Uw WWI G fN CIIZ Y� FD NAIL DISK LB 5610" SURVEYORS NOTES: 1. UNLESS OTHERWISE NOTED 0 PLATTED EASEMENTS ARE SHOWN HEREON. 2. ALL LOT DIMENSIONS SHO1�yNLY ARE PER PLAT UNLESS OTHERWISE SHOWN. 3. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE LOCATED UNLESS OTHERWISE SHOWN. 4. THIS SITE LIES WITHIN FLOOD INSURANCE RATE MAP ZONE X MAP# 12111C0070 J DATED: 2-16-12. 5. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATION BY THE SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY.+ 6. BEARINGS SHOWN HEREON ARE BASED ON THE EAST LINE OF LOT 183 AS BEING ASSUMED TO BEAR S0070'51"I. 7. U.E. DENOTES UTILITY EASEMENT. D.E. DENOTES DRAINAGE EASEMENT. 8. THE ACCURACY OF THIS SURVEY IS PREMISED ON. THE EXPECTED USE OF THE SURVEY. THE - EXPECTED USE / PURPOSE OF THIS SURVEY IS HOME CONSTRUCTION. ACCURACY=1 FOOT IN 7.500 FEET OR BETTER. 9. ADDITIONS OR DELETIONS TO THIS SURVEY MAP BY ANYONE OTHER THAN THE SIGNING SURVEYOR IS PROHIBITED WITHOUT WRITTEN CONSENT, AND EEDRAINAGSE PROPOSED TINGx�o3 EXISTING ELEVATION PROPOSED ELEVATION PROPOSED PLOT PLAN I(OuBjEdT TO doNTRAdToR. HEALTH DEPT., AND BUILm"d DEPT. APPROVAL) ALL ELEVATIONS SHOWN HEREON ARE BASED ON NORTH AMERICAN VERTICAL DATUM OF 1988(N.A.V.D.'88) MIN. S BACK REQ. FRONT SIDES CNR SIDES REAR — ZNG, TECH. FD IRC "PSM 6330" 9 125.50' W I M � I � C I I 0 PRIPOS p 16' 6 !i RIVEWY +` 275 0' 1. FD IRC "PSM 6330" 5322 VESPERA STREET SCALE:1"=30' Atlantic Land Designs of the Treosure Coast, LB7468 F54 NE Jensen Beach Blvd. Jensen Beach, FL 3495 Mailing Address: P.O. Box 1421 Jensen Beach, FL 34958 ALD5543@gmail.com (772) 398-4290 DATE: 4-29-21 DRAIN: Dill \JC 2021-0418 LAST FIELD DATE: 4-28-21 N i En LOT 182 0 VACANT 22 00 E=PROPOSED t In m o_ v N89°39'09"W 110.00' .PSM s33o ----r 5' D.E. In-m N 0 52.67 29.8-VN 2.83'L17o _ � PROPOSED R/EgSIDENCE „ o LOT 183 YODEL 151222.tOCAR — a VACANT 29.83' N89°39'09"NI 110.00' "PSM s33o^ LOT 184 VACANT PROPOSED FFt = 22.40 01 r O) I m Certified to: Adams Homes of Northwest Florida, Inc. I hereby certify that the -survey sho*n hereon is true and correct and is based on actual measeurements taken in the field. 3IM CESy G�gYIFICAr,'y0 f PSM 5543 V Diglla sIgnedbyJameaACe9rolr. ON:aWamm A.CesimJr.o AdandtUnd OWgn..f am 7esiroJr::,'TC Inc ou ema0=AWSSe3®gmaimm, c�U3O462021M,07M.33:19-0,IW P STATE OFTVALID W 'AUTHENTICATED ELECTRONIC FLORIDP a c CFO SIG AND AUTHENTICATED ELECTRONIC SEAL SURVEYOR FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Lot 183 Phase 3 Waterstone 1512 BGRS Builder Name: ADAMS HOMES Street: 5322 Vespera Street Permit Office: City, State, Zip: Fort Pierce , FL , 34951 Permit Number: Owner: Jurisdiction: 661000 Design Location: FL, ST_LUCIE_CO_INTL County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$1642.6 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1347.70 ft2 b. Frame - Wood, Adjacent R=13.0 294.94 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Types (1512.0 sqft.) Insulation ' Area a. Under Attic (Vented) R=30.0 1512.00 ft2 6. Conditioned floor area above grade (ft2) 1512 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 7. Windows(174.2 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.33 118.38 ft2 a. Sup: Attic, Ret: Main, AH: Main 6 302.4 SHGC: SHGC=0.23 b. U-Factor: Dbl, U=0.33 35.00 ft2 13. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.55 17.78 ft2 SHGC: SHGC=0.70 Area Weighted Average Overhang Depth: 3.466 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.275 a. Electric Heat Pump 28.2 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) N/A ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. Floor Types (1512.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 16. Credits Pstat Total Proposed Modified Loads: 49.16 Glass/Floor Area: 0.115 A SS Total Baseline Loads: 50.06 !�1 I hereby certify that the plans an a tions covered b -7TF'v1e-v0vf the plans and OZ>rLB ST,7O, this calculation are in complia le he Florida y specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed 91" C DATE: 117-1.5 201 Winn KPnmany this building will be inspected for compliance with Section 553.908 a I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGEIVT. -` BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/15/2021 4:10 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 4 7 FORM'R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Lot 183 Phase 3 Waterstone Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1512 Lot # 183-3 ., Owner Name: Total Stories: 1 Block/Subdivision: Waterstone # of Units: 1 Worst Case: No PlatBook: Builder Name: ADAMS HOMES Rotate Angle: 0 Street: 5322 Vespera Street Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: 661000 Whole House Fan: No City, State, Zip: Fort Pierce Family Type: Detached , FL , 34951 New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, ST_LUCIE_CO_INTL FL_VERO_BEACH _MUNI 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Block1 1512 13608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1512 13608 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0 1512 ft2 ---- 0.47 0 0.53 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1691 ft2 378 ft2 Medium N 0.85 N 0.85 No 0 26.57 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 1512 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 30 Blown 1512 ft2 0.11 Wood 7/15/2021 4:10 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 4 FORM'R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 1 E Exterior Concrete Block - Int Insul Main 4.1 39 10 8 9 348.5 ft2 0 0 0.6 0 2 SW Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Int Insul Main 4.1 18 2 8 3 149.9 ft2 0 0 0.6 0 4 SE Exterior Concrete Block - Int Insul Main 4.1 2 3 8 0 18.0 ftz 0 0 0.6 0 5 W Exterior Concrete Block - Int Insul Main 4.1 53 7 8 7 459.9 ft2 0 0 0.6 0 _ 6 N Exterior Concrete Block - Int Insul Main 4.1 41 2 8 7 353.3 ft2 0 0 0.6 0 7 - Garage Frame - Wood Main 13 35 9 8 3 294.9 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated Main None .25 3 6 8 20 ft2 2 - Wood Main None .25 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Vinyl Low-E Double Yes 0.55 0.7 N 17.8 ft' 13 ft 0 in 1 ft 4 in None None 2 E 1 Vinyl Low-E Double Yes 0.33 0.23 N 6.9 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 SW 2 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 4 S 3 Vinyl Low-E Double Yes 0.32 0.31 N 3.0 ft2 7 ft 4 in 0 ft 9 in Drapes/blinds None 5 S 3 Vinyl Low-E Double Yes 0.33 0.21 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 6 SE 4 Vinyl Low-E Double Yes 0.33 0.21 N 10.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 7 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 9.8 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 8 W 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.2 ft2 1 ft 4 in 1 ft 0 in Drapes/blinds None 9 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 30.0 ft2 6 ft 8 in 0 ft 10 in Drapes/blinds None 10 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 23.2 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None 11 N 6 Vinyl Low-E Double Yes 0.33 0.23 N 32.4 ft2 1 ft 4 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 390 ft2 390 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 1587.6 87.1 163.52 .1324 7 7/15/2021 4:10 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 4 FORM R405-2020 INPUT SI IMMARY rN9=rk1 IQT QGonor HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Sing[ HSPF:8.5 28.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 15 28.4 kBtu/hr cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 40 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Mode[ # Collector Model # Area Volume FEF None None ft' DUCTS ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 302.4 ft Main 75.6 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Feb Jan f X Feb Mar Mar Apr f Apr f Jun X Jul May Jun4 Jul May ri X Aug f Aug Se 4 Sep Oct Oct Nov Nov Dec Dec Venting Ventin Jan [ Feb X Mar [X] A r [ Ma Jun [ Jul [ Au [ Se [X Oct X X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftZ 0 ft 0.3 Main 7/15/2021 4:10 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 4 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5322 Vespera Street, Fort Pierce, FL, 34951 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1347.70 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=13.0 294.94 ft2 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1512.00 ft2 6. Conditioned floor area (ft2) 1512 b. N/A R= ft2 7. Windows- Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.33 118.38 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.23 a. Sup: Attic, Ret: Main, AH: Main 6 302.4 b. U-Factor: Dbl, U=0.33 35.00 ft2 SHGC: SHGC=0.21 13. Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.55 17.78 ft2 a. Central Unit 28.4 SEER:15.00 SHGC: SHGC=0.70 d. U-Factor: other (see details) 3.00 ft2 SHGC: other (see details) 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.466 ft. a. Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average SHGC: 0.275 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): N/A ft2Cap: a. Electric 40 gallons SHGC(AVG): N/A EF:0.94 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1512.00 ft2 Credits (Performance method) Pstat b. N/A R= ft2 c. N/A R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: - Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/15/2021 4:10 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1