HomeMy WebLinkAboutSurveyLOT 5 I LOT 4
VACANT VACANT
57'42'15"E 21.47'
_R
N52'50'08"E 110.76'
43.34'
PROPOSED
A/C PAD
O r
o b)
^
59.67'
a)
o
LOT 3
ar II J
c
VACANT
PROPOSED 4.67'
0
CID
MODEL 4EBB/D PROPOSED `
06
N
F.F.E.=18.81 COVERD ENTRY
I
EXISTING BUILDING
PROPOSED
8.00.
PAD EL=18.38 4.33'
COVERED LANAI
Cq
0 0
4.67' c
C
45.14'
8.00'
51.6T
--------I------
----------
�
o
P
/
o /
14I I
0
PROPOS D /
SANIT Y
SER CE�
d U w�w
OZ>.
tY O'ZE
0_UC] i
�h S57'1519 W 130.00, B.B. L
--I---------------------------- PROPO ED
--------Q
---� ------WATER--5ER E I-----
I Co
BENCH ARK
SANITARY MANGLE 1 '
I = 1I a LOT 3 AREA SUMMARY IN SQUARE FEET RIM EL. 6.19
SOD: 6007f iF
DRIVEWAY/WALKWAY: 713f DRAINAGE I LET _
I GRATE EL. I = 5.82 67
I
LOT 2 1 1
VACANT
I I � •
I
THOMAS P. KIERNAN DATE
Professional Surveyor & Mapper
Florida Certificate No: 6199
,=50 ,
0'
=9'4 '
9" .
.79'
PC
1
a�
IZ
O d ..
o
j.
� LO
i
\ �
I �z�
oz
QS
oQ
O� > a
aQ .
5.00' o N
=500 0 '
6'30' "
=144.1 '
TO T
)RAIN G INLET
TE EL. - 15.82
PROPERTY ADDRESS
3449 TRINITY CIRCLE, FORT PIERCE, FLORIDA
LEGAL DESCRIPTION
Being all of Lot 3, according to the plat of CREEKSIDE PLAT NO.
4,, as recorded in Plat Book 85, Page 5, Public Records of St. GRAPHIC SCALE
Lucie County, Florida. 20 0 10 20
Containing 0.203 acres, more or less.
IN
LB EGEND & ABREVIATIONS i r )
1 lnoh - 20 20 !R
BB DENOTES BEARING BASE
CBS DENOTES CONCRETE BLOCK STRUCTURE
C DENOTES CHORD BEARING & DISTANCE
q DENOTES CENTER LINE
D.E. DENOTES DRAINAGE EASEMENT
F.F.E. DENOTES FINISH FLOOR ELEVATION
FND DENOTES FOUND
IR/C DENOTES IRON ROD AND CAP
L.B. DENOTES LICENSED BUSINESS
L DENOTES ARC LENGTH
N/D DENOTES NAIL AND DISK
O.S.T. DENOTES OPEN SPACE TRACT
P.S.M. DENOTES PROFESSIONAL SURVEYOR & MAPPER /FRO.
K REQ.
P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR R DENOTES RADIUS
R/WDENOTES RIGHT OF WAY U.E. DENOTES UTILITY EASEMENT W.M.T. DENOTES WATER MANAGEMENT TRACT
A DENOTES INCLUDED ANGLE DENOTES DRAINAGE FLOW
DENOTES PROPOSED ELEVATION TECH.
DENOTES FIRE HYDRANT
GENERAL NOTES
1. The last date of field work was 5-14-20
2. Additions or deletions to survey maps or reports by other than the signing party or parties is
prohibited without written consent of the signing party or parties.
3. Reproductions of this map are not valid without the original signature and raised seal of a Florida
Licensed Surveyor and Mapper.
4. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record,
ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This information should be obtained
through appropriate title verification.
5. All above ground fixed .improvements, if any, have been located and shown hereon.
6. Underground foundations and improvements were not located as part of this survey.
7. Flood Note: By graphic plotting only, the portion of this property scheduled for building improvements
is in Zone "X", according to the LOMA Case No. 21-04-138A associated to the Flood Insurance Rate
Map, Community Panel No. 12111CO170 J, effective date February 16, 2012. The exact designation can
only be determined by an elevation certificate. There may be additional map Amendments affecting this
property.
8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel and the use of
existing field elevation data.
9. The bearings shown hereon are based on Plat information and are referenced to the Northerly line of
Lot 3 which bears South 57'15'19" West and all bearings are relative thereto.
10. No easements are shown hereon other than those depicted on the plat. No search of the public
records has been performed to find additional easements that may .exist.
11. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988.
12. The building setbacks shown hereon, although based on the best available information, are not certified
to and must be verified prior to design or construction.
03/31/2021 JEB Revise Model
3
CULPEPPER &
Date:02-10-2021
Date: 02-10-2021
�
FB: N/A
■
TERPENING INC
SCALE 1 "=20'
DRAWN BY: RMR
2980 SOUTH 251h STREET • FORT PIERCE. FLORIDA 34981
PHONE 772464-3537 • FAX 772464-9497 • www.ct-eng.com
FIELD: PK
STATE OF FLORIDA BOARD OF PROFESSIONAL
ENGINEERS AUTHORIZATION NO. 4286 -