Loading...
HomeMy WebLinkAboutDensity ReportMeadowood Lot 18-digiUES Project No: Workorder No: Report Date: 3310.1500002.0000 239820-1 07/16/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:GHO HOMES CORPORATION UES Technician:Mark Rogers 590 NW Mercantile Place Port St. Lucie, FL 34986 Date Tested:07/16/2021 Project:MEADOWOOD SUBDIVISION (FDC) Meadowood Dr. Various Lots,Fort Pierce, County, FL 34951 Type of Test: Area Tested:Lot 18 - 3613 Grove Court, Ft. Pierce Field:ASTM D-6938 Nuclear Gauge Method Material:Backfill Laboratory:ASTM D1557 Modified Proctor Reference Datum:0 = Top of Fill The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 Northeast corner of lot 0-1 ft 117.8 11.1 114.0 10.8 97 Pass 2 Southwest corner of lot 0-1 ft 117.8 11.1 115.3 10.9 98 Pass 3 Center of lot 0-1 ft 117.8 11.1 115.7 10.7 98 Pass Remarks:Permit: 21060380 Reviewed By GFA International, Inc FBPE Registry No.4930 John Kent Senior Project Engineer STATE OF FLORIDA Professional Engineer No. 63218 This item has been digitally signed and sealed by John Kent on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1