HomeMy WebLinkAboutDensity ReportMeadowood Lot 18-digiUES Project No:
Workorder No:
Report Date:
3310.1500002.0000
239820-1
07/16/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:GHO HOMES CORPORATION UES Technician:Mark Rogers
590 NW Mercantile Place
Port St. Lucie, FL 34986
Date Tested:07/16/2021
Project:MEADOWOOD SUBDIVISION (FDC)
Meadowood Dr. Various Lots,Fort Pierce, County, FL 34951
Type of Test:
Area Tested:Lot 18 - 3613 Grove Court, Ft. Pierce Field:ASTM D-6938 Nuclear Gauge Method
Material:Backfill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Northeast corner of lot 0-1 ft 117.8 11.1 114.0 10.8 97 Pass
2 Southwest corner of lot 0-1 ft 117.8 11.1 115.3 10.9 98 Pass
3 Center of lot 0-1 ft 117.8 11.1 115.7 10.7 98 Pass
Remarks:Permit: 21060380
Reviewed By
GFA International, Inc
FBPE Registry No.4930
John Kent
Senior Project Engineer
STATE OF FLORIDA
Professional Engineer No. 63218
This item has been digitally signed and sealed by John Kent on the
date adjacent to the seal. Printed copies of this document are not
considered signed and sealed and the signature must be verified on
any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1