HomeMy WebLinkAboutPROJECT INFORMATION2 REPLACE DOORS IN 2 OPENINGS ONLY.
6" X 80" NEW DOORS TO BE IMPACT RESISTANT -
HURRICANE SHUTTERS NOT REQUIRED.
X
'• I
1
OPENING
PRODUCT
❑ESIGN
❑PENING
SQ
WIND
PRESSURES
APPROVAL
PRESSURES
COMMENTS
NO WIDTH. HGT.
FTG.
ZONE
POS. NEG.
(N.O.A. #)
POS NEG
1
36
80
20.00
4
361
-39.3
FL16708.2
65.0
-65.0
FRONT ENTRY - LSMI
2
36
80
20.00
5
36.1
-47.2
FL16708.1
65.0
1 -65.0
UTILITY 1 LAUNDRY ROOM - LSMf
REPLACE EXISTING DOORS AS DESIGNATED WITH NEW FLORIDA BUILDING CODE APPROVED DOORS.
NO CHANGE IN SIZE. NO MODIFICATION TO OPENINGS
ALL DOOR FRAMES TO BE ATTACHED THROUGH EXISTING BUCKS WITH MINIMUM 114" TAPCON SCREWS INTO CONCRETE
WITH A MINIMUM 1 114" PENETRATION PER MANUFACTURER'S PRODUCT APPROVAL DOCUMENTS
LESS THAN 30% OF STRUCTURE'S VALUE. NOT A RENOVATED BUILDING EXEMPT FROM 2020 ENERGY CONSERVATION CODE.
SEE WIND LOAD CHART ON NEXT PAGE FOR SPECIFIC OPENING PRESSURES
DESIGN PRESSURES OF PRODUCT MEET OR EXCEED SPECIFIC OPENING PRESSURES
MEAN ROOF HEIGHT = 11 FT 10 IN
JONES RESIDENCE
1936 WYOMING AVENUE
DOOR REPLACEMENT PLAN