FL #FL5325-R8
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer Intertape Polymer, Inc.
Address/Phone/Email 50 Abbey Avenue
Truro, NON-US
(902) 896-1033 Ext 4
tmacneil@itape.com
Authorized Signature Tawnya L MacNeil
tmacneil@itape.com
Technical Representative Sandro Di Pede
Address/Phone/Email 410-130 Bridgeland Ave
Toronto
(416) 780-1700
sandrodipede@bellnet.ca
Quality Assurance Representative Sandro Di Pede
Address/Phone/Email 410-130 Bridgeland Ave
Toronto
(416) 780-1700
sandrodipede@bellnet.ca
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation Report Robert Nieminen
Florida License PE-59166
Quality Assurance Entity QAI Laboratories
Quality Assurance Contract Expiration Date 12/31/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL5325_R8_COI_2020_01_COI_NIEMINEN.pdf
Referenced Standard and Year (of Standard)Standard Year
ASTM D1970 2015
ASTM D226 (physicals)2009
ASTM D4533 2015
ASTM D4798 2011
ASTM D4869 2016
ASTM D5035 2011
TAS 117(B)1995
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/15/2020
Date Validated 12/17/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Summary of Products
FL #Model, Number or Name Description
5325.1 PALISADE Roofing Underlayments Synthetic Roofing Underlayments
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER Section 5 for Limits of Use.
Installation Instructions
FL5325_R8_II_2020_12_15_FINAL_ER_SDP_UNDERLAYMENTS_FL5325-R8.pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL5325_R8_AE_2020_12_15_FINAL_ER_SDP_UNDERLAYMENTS_FL5325-R8.pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida. :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public-records request, do not send electronic mail to this entity. Instead, contact the office by phone or
by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the
Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts: