Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED FL5325_R8_II_2020_12_15_FINAL_ER_SDP_UNDERLAYMENTS_FL5325-R8
NEMO|etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT SDP Advanced Polymer Products, Inc. 410-130 Bridgeland Avenue Toronto, Ontario M6A 1Z4 Canada (866) 747-4035 Evaluation Report S19010.07.09-R4 FL5325-R8 Date of Issuance: 07/03/2009 Revision 4: 12/15/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the 7th Edition (2020) Florida Building Code sections noted herein. DESCRIPTION: PALISADE™ Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.1.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words “NEMO|etc. Evaluated” may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 12/15/2020. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ©2018, NEMO ETC, LLC NEMO|etc. NEMO ETC, LLC Evaluation Report S19010.07.09-R4 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ & HVHZ EVALUATION FL5325-R8 PALISADE™ Roof Underlayments; (866) 747-4035 Revision 4: 12/15/2020 Page 2 of 5 ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Underlayment Compliance Statement: PALISADE™ Roof Underlayments, as produced by SDP Advanced Polymer Products, Inc., have demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through testing in accordance with the applicable sections of the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.1.1 / R905.1.1, 1518.4 Material standard ASTM D226 2009 1507.1.1, 1507.2.4, 1507.2.9.2 / R905.1.1, R905.2.8.2 Material standard ASTM D1970 2015 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Tear strength ASTM D4533 2015 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) Tensile strength ASTM D5035 2011 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 2016 1523.6.5.2.9, TAS 110 Comparative Rupture TAS 117, Appendix B 1995 TAS 110 Accelerated Weathering ASTM D4798 2011 3. REFERENCES: Entity Examination Reference Date NEMO (TST6049) ASTM D226, D1970, D4533, D4798, D4869, D5035, TAS 117(B) 4j-SDP-20-SSUDL-01 12/15/2020 Miami-Dade (CER1592) HVHZ Compliance 16-1025.02 11/10/2016 QAI (QUA7628) Quality Control Service confirmation 12/04/2020 QAI (QUA7628) Quality Control Florida BCIS Current 4. PRODUCT DESCRIPTION: Product Material Standard Plant(s) Description 4.1 PALISADE™ 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / R905.1.1.1(2&3, Exception), R905.1.1.1(5) / 1518.4 Binh Duong, Vietnam synthetic roofing underlayment comprised of a polyolefin-coated, woven construction with dual skid resistant surfaces 4.2 PALISADE™ SA-HT ASTM D1970 Shandong, China self-adhering roofing underlayment comprised of a polyolefin-coated, woven upper surface and self-adhering bottom surface NEMO|etc. NEMO ETC, LLC Evaluation Report S19010.07.09-R4 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ & HVHZ EVALUATION FL5325-R8 PALISADE™ Roof Underlayments; (866) 747-4035 Revision 4: 12/15/2020 Page 3 of 5 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC non-HVHZ and HVHZ jurisdictions, where “HVHZ” is defined as Broward and Miami-Dade Counties. Limitations and Installation requirements that differ by jurisdiction are designated herein as “non-HVHZ” and “HVHZ” accordingly. 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 or FBC HVHZ 1516 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 PALISADE™ Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS FBC non-HVHZ Section: 1507.2 1507.3 1507.4 & 1507.5 1507.7 1507.8 & 1507.9 FBC HVHZ Section: TAS 110(S10), RAS 115 TAS 110(S11), RAS 118, 119 & 120 RAS 133 TAS 110(S11) RAS 130 Underlayment Asphalt Shingles Clay and Concrete Tile Metal Slate or Slate-Type Shingles Wood Mechanical Attach Adhesive-Set Panels Shingles Shingles Shakes PALISADE™ Yes non-HVHZ: No HVHZ: Yes (Base Sheet in 2-ply system only) Yes Yes non-HVHZ: No HVHZ: Yes PALISADE™ SA-HT Yes No Yes Yes non-HVHZ: Yes (joint strips per 1507.1.1.3 / R905.1.1.3) HVHZ: Yes 5.7 Allowable Substrates: TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment Application Primer Substrates PALISADE™ SA-HT self-adhering None plywood PALISADE™ 5.8 Attachment Limitations: 5.8.1 Non-HVHZ: For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with the manufacturer’s installation instructions, but – for mechanically attached underlayments or base sheets - not less than FBC 1507.1.1 or R905.1.1. 5.8.2 HVHZ: Refer to Section 6. 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS Underlayment Prepared Roof Cover Installation Type Maximum Exposure (days) PALISADE™ Mechanically attached 180 PALISADE™ SA-HT Mechanically attached 30 NEMO|etc. NEMO ETC, LLC Evaluation Report S19010.07.09-R4 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ & HVHZ EVALUATION FL5325-R8 PALISADE™ Roof Underlayments; (866) 747-4035 Revision 4: 12/15/2020 Page 4 of 5 6. INSTALLATION: 6.1 General: 6.1.1 PALISADE™ Roof Underlayments shall be installed in accordance with SDP Advanced Polymer Products, Inc. installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.1.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). 6.2 Non-HVHZ: 6.2.1 PALISADE™: Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) or 1507.1.1.1(5) or FBC Residential R905.1.1.1(2, Exception), R905.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer’s installation instructions. FBC requirements take precedence over the manufacturer’s installation instructions Minimum fasteners shall be corrosion resistant, ring-shank cap nails shall be as set forth in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3. 6.2.2 PALISADE™ SA-HT: Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer’s installation instructions. When installed over mechanically attached PALISADE™, the PALISADE™ shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.3 HVHZ: 6.3.1 Approved Assemblies: Assembly No. 1 Deck Type 1: Wood, non-insulated Deck Description: Min. 19/32-inch plywood or wood plank System Type E: Underlayment mechanically fastened to deck Underlayment: One or more plies of PALISADE™ with min. 4-inch side laps and min. 6-inch end laps. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the laps and 12- inch o.c. at three (3) equally spaced, staggered center rows. Surfacing: FBC HVHZ Approved prepared roof assembly, per Table 1. Assembly No. 2 Deck Type 1: Wood, non-insulated Deck Description: Min. 19/32-inch plywood or wood plank System Type E: Base sheet mechanically fastened to deck, underlayment adhered Base Sheet: One or more plies of PALISADE™ with min. 4-inch side laps and min. 6-inch end laps. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the laps and 12- inch o.c. at three (3) equally spaced, staggered center rows. Cap Ply: PALISADE™ SA-HT, self-adhered in accordance with SDP Advanced Polymer Products, Inc. published instructions. Surfacing: FBC HVHZ Approved prepared roof assembly, per Table 1. NEMO|etc. NEMO ETC, LLC Evaluation Report S19010.07.09-R4 Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ & HVHZ EVALUATION FL5325-R8 PALISADE™ Roof Underlayments; (866) 747-4035 Revision 4: 12/15/2020 Page 5 of 5 Assembly No. 3 Deck Type 1: Wood, non-insulated Deck Description: Min. 19/32-inch plywood or wood plank System Type E: Base sheet mechanically fastened to deck, underlayment adhered Base Sheet: One or more plies of PALISADE™ with min. 4-inch side laps and min. 6-inch end laps. Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the laps and 12- inch o.c. at three (3) equally spaced, staggered center rows. Cap Ply: CertainTeed “Flintlastic SA Cap” (NOA 20-0723.36), self-adhered to the base sheet. See current FBC HVHZ approval for installation guidelines and limits of use of the cap ply. Surfacing: FBC HVHZ Approved tile roof system. Note: Authority Having Jurisdiction shall verify that Cap Ply underlayment listed herein hold current FBC HVHZ Product Approval and/or Miami-Dade NOA for use as a tile underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for products and production locations having met codified material standards. 9. QUALITY ASSURANCE ENTITY: QAI Laboratories – QUA7628; (604) 527-8378; mlansdowne@qai.org - END OF EVALUATION REPORT -