OLNER TECHNOLOGIES,INC.
FLORIDA INSTALLATION INSTRUCTIONS FOR THE
MODEL 1191 'YLaEWUALLSTEEL FOUNDATIOfi SYSTEM
MODEL 1101"W(STEPS 1-151
LONGITUDINAL ONLY:FOLLOW STEPS 1.9
FOR ADDING LATERAL ARM:Follow Steps 10.15
FOR CONCRETE APPLICATIONS:Follow Steps 1tr19
ENGWEERS STAMP
ENGINEERS STAMP,
1. SPECIAL CIRCUMSTANCES: If the following Conditions occur- STOP! Contact Oliver Technologies at 1-800-264-7437
a) Pier height exceeds 48" b) Length of home exceeds 76'c)Roof eaves exceed 16" d) Sidewall height exceed 96'
e) Location is within 1500 feet Of Coast
INSTALLATION OF GROUND PAN
2. Remove weeds and debris in an approximate two foot square to expose firm soil for each ground pan (C)
3. Place ground pan (C)directly below chassis I-beam . Press or drive pan firmly into soil until flush with or below soil.
SPECIAL NOTE: The longitudinal "V" brace system serves as a pier under the home and should be loaded as any
other pier. It is recommended that after leveling piers, and one-third inch (1/3") before home is lowered completely on
to piers, complete steps 4 through 9 below then remove jacks.
INSTALLATION OF L�ONGIT�JDINAL"V" BRACE SYSTEM
NOTE: WHEN INSTALLING THE LONGITUDINAL SYSTEM Q(lll�Y, A IMUM OF 2 SYSTEMS PER FLOOR SECTION IS REQUIRED.SOIL TEST
PROBE SHOULD BE USED TO DETERMINE CORRECT TYPE OF ANCHOR PER SOIL CLASSIFICATION.IF PROBE TEST READINGS ARE BETWEEN
175 8 275 A 5 FOOT ANCHOR MUST BE USED.IF PROBE TEST READINGS ARE BETWEEN 276 &350 A 4 FOOT ANCHOR MAY BE USED.USE
GROUND ANCHORS WITH DIAGONAL TIES AND STABILIZER PLATES EVERY 5'4".VERTICAL TIES ARE ALSO REQUIRED ON HOMES SUPPLIED
WITH VERTICAL TIE CONNECTION POINTS(PER FLORIDA REG) .
4. Select the correct square tube brace (E) length for set-up (pier)height at support location. (The 18"tube is always
used as the bottom part of the longitudinal arm). Note' Either tube can be used by itself, cut and drilled to length as long as a
40 to 45 degree angle is maintained. V """' ?I
PIER HEIGHT 1.25"ADJUSTABLE 1.50"ADJLiSTABLt1
(Approx. 45 degrees Max.) Tube Length Tube Length t�tl_,
I :ooAA
7 3)4"to 25" 22' 18"
24 3/4' to 32 1/4' 32" 18"
33"to 41" 44" 18"
40'to 48" 54" 18"
5. Install (2) of the 1.50" square tubes(E (18- tube) ) into the'U" bracket (J). insert carriage bolt and leave nut loose for final
adjustment.
6. Place I-beam connector(F)loosely on the bottom flange of the I-beam-
7. Slide the selected 1.25"tube(E)into a 1.50'tube(E)and attach to I-beam connectors (F)and fasten loosely with bolt and nut.
8. Repeat Steps 6 through 7 to create the"V pattern of the square tubes loosely in place. The angle is not to exceed 45
degree and not below 40 degrees.
9 After all bolts are tightened, secure 1.25"and 1.50' tubes using four(4) 1/4"-14 x 3/4" self-tapping screws in pre-drilled holes
INSTALLAMN OF LATERAL TELESCOPINQ TRANSVERSE ARM SYSTEM
THE MODEL 1101 "V"(LONGITUDINAL 6 LATERAL PROTECTION)CummATEs Twr-NFFn FOR MOST STABILIZER PLATES 8 FRAME TIES.
NOTE:THE USE OF THIS SYSTEM REQUIRES VERTICAL TIES SPACED AT 5'4".
FOUR FOOT(4')GROUND ANCHOR MAY BE USED OCCEPT WHERE THE HOME MANUFACTURER SPECIFIES DIFFERENT.
10. Install remaining vertical tie-down straps and 4'ground anchors per home manufacturer's instructions. NOTE: Centerline
anchors to be sized according to soil torque condition Any manufacturer's Specifications for sidewall anchor loads in excess of
4,000 lbs. require a 5'anchof per Florida Code.
11. NOTE:Each system is required to have a frame be and stabilizer attached at each lateral arm stabilizing location. This frame tie 8
stabilizer plate needs to be located within 18"from of center ground pan.
12. Select the correct square tube brace (H) length for set-up lateral transverse at support location. The lengths come in either 60"
or 72" lengths.(With the 1.50'tube as the bottom tube, and the 125"tube as the inserted tube.)
13. Install the 1.50 transverse brace (H)to the ground pan connector(0)with bolt and nut.
14. Slide 1.25-transverse brace into the 1.50' brace and attach to adjacent I-beam connector( I )with bolt and nut.
15. Secure 1.50' transverse arm to 1.25-transverse arm using four(4) 114"- 14 x 3/4"seif-tapping screws in pre-drilled holes
OLIVER TECHNOLOGIES, INC. Telephone:931-7%-4555
1-800-284"7437 Fax:931-796-8811
www.owertechnologies.com
page 2
INSTALLATION USING CONCRETE RUNNER/FOOTER rcvisioa 6107
16. A concrete runner,footer or slab maybe used in place of the steel ground pan
a) The concrete shall be minimum 2500 psi mix
b) A concrete runner may be either longitudinal or transverse, and must be a minimum of 8'deep with a minimum width of 16 inches
I longitudinally or 18 inches transverse to allow proper distance between the concrete bolt and the edge of the concrete(see below).
c) Footers must have minimum surface area of 441 sq in.(i.e. 21'square),and must be a minimum of 8"deep.
d) If a full saab is used,the depth must be a 4'minimum.
Special inspection of the systsm bracket installation is not required. Footers must allow for at least 4'from the concrete bolt to the edge
of the concrete.
NOTE: The bottom of all footings, pads,slabs and runners must be per local jurisdiction.
LONGITUINNAL: (Model 1101 LC "V")
17. When using Part# 1101-W-CPCA(wetseth simply install the bracket in runnerlfooter OR When installing in is lred concrete use Part#
101-D-CPCA(drvset). The 1101 (dryset)CA bracket is attached to the concrete using (2)5/8'x3'concrete wedge bolts(Simpson part#
S162300H 5/8'X 3'or Powers equivalent). Place the CA bracket in desired location Mark bolt hole locations, then using a 5/8"diameter
masonry bit, drill a hole to a minimum depth of Y. Make sure all dust and concrete is blown out of the holes. Place wedge bolts into drilled
holes,then place 1101 (dry set) CA bracket onto wedge bolts and start wedge bolt nuts. Take a hammer and lightly drive the wedge bolts
down by hitting the nut(making sure not to hit the top of threads on bolt). The sleeve of concrete wedw molt needs to be at or be(owyLe oo
of concrete. Complete by tightening nuts.
LATERAL: (Model 1101 TC "V")
18. For wet set(part# 1101-W-TACA)installation simply install the anchor bolt into runnertfooter. For dry set installation(part# 1101-D-TACA)
mark bolt hole locations,then using a 518'diam. masonry bit, drill a hole to a minimum depth of 3'. Make sure all dust and concrete is
blown out of the We. Place wedge bolts(Simpson part#S162300H SIB'X 3'or Powers equivalent)into(D)concrete dry transverse
connector and into drilled hole. If needed, take a hammer and lightly drive the wedge bolts down by hitting the nut(making sure not to hit
the top of threads on bolt), then remove the nut. The sleeve of concrete wedge bolt needs to be at of below the too of QA)Q ste
19. When using part# 1101 CVW(wetset)or 1101 CVD (dryset), install per steps 17 & 18_
Notes:
1. LENGTH OF HOUSE IS THE ACTUAL BOX SIZE [�
2. • =STAIR PLATEAND FRAME TE LOCATION (revels iD � 9
be bcabd wti118 i-lcttesdoertWcfgand{sett oroor)a7ege)
3. K3-- LOCA71 IN OF LONG n_Ct 4L BRACING ONLY
4. l &LCNGMJDt A-LOCAT OIJS
REQUIRED NUMBER AND LOCATION OF MODEL 1101 "V" OR 1101 Q "V"
GRACES FOR UP TO 4112 ROOF PITCH
ALL WIDTHS; AND LENGTHS UP TO 52'
•
ALL WIDTHS; AND LENGTHS OVER 52' TO 80'
• • • •
3—
HOMES WITH 5/12 ROOF PITCH REQUIRE.- PER FLORIDA REGULATIONS
6 systems for home lengths up to 52' and 8 systems for homes over 52' and up 80'. One stabilizer
plate and frame tie required at each lateral bracing System.
Fonda approved 4'ground - �:t--•� pap
anchors may be used in all _ mNW=07
locations except where r
home manufacturers spec- ; I
fications for sidewall straps .4 < '
are in excess of 4,000 bs.
I- Transverse art I-beam i ;; r l t•r
These locations require a 5' connecloir k_
anchor.Per Florida Code. "<H- Tmnf ;"arm
TOP(1.251)
bottom(1s•) C=GROUND PAN
D=GROUND PAN CONNECTOR
D-Ground F-:'V'brace I-beam U BRACKETS TRANSVERSE
Pan connectors E=TELESCOPING V BRACE
transverse TUBE ASSEMBLY W/1.5 SOT
-
connectors t-ground Pan TOM TUBE AND 1.25 TUBE .
v-/ V Bracket INSERT «ka� Wlr<lr Q2._
• x; �
IF `V" BRACE 1-BEAM ;'3" +
TORS ASSEMBLY �4` •' •� .w �`�
E-Y Brace Tu H=TELESCOPING To.W E r'1 sa
TOP ARM ASSEMBLY* No.-'I5$3G
Bottom (1.5-) I=TRANSVERSE Af +EAM
GrO'"id Pa" CONNECTOR �r w
J=V PAN BRACKET 4_Vtt
T T f
e :°:f
: a
Model # 1101 'V" �` ���•j0�1 . _;= ;�=
I-beam a amp
Altemaki Role for (1)Per Assembly
Longitude dry =:: NaMAisr Beam Flange _
concrete bracket
part# 1101 D-CPCA 4411
IrZ X V
Wet bracket part#
1101 W-CPCA not _ - cae6.lrl�xzwz ' Model 1101 CVD
shown caalaBeBox�idut.
..: ..._.. ..........:...... . Model 1101 CVW
I-sEAM CONNECTOR SPJW2(ET
not shown l
Florida approved 4'ground -----»- C =CONCRETE FOOTER/RUNNER
anchors may be used in all
locations except where home D =CONCRETE U BRACKET TRANSVERSE
manufacturers specifications CONNECTOR(connects with grade 5-12'x 2
for sidewall straps are in I_ Tcat resse arm I-beam + 1 t 12'"carriage bolt&-nut)
to c do of require
Ibs.These k_ r t E=TELESCOPING V BRACE
locations require a 5'anchor. oDtkne�yDr
Per Florida Code. / r\H=Transverse arm TUBE ASSEMBLY W/ 1.5 BOT-
/ Top(tss-) . TOM TUBE AND 1.25 TUBE
/ bottom(1-s•) INSERT
F='V' BRACE I-BEAM CONNECTOR ASSEMBLY
moo^ F-:v trat9 t.beem : (connects with grade 5-1/2`x 4'carriage bolt
tr brad connectors (rr )
transverses H=TEL
connec►ms ESCOPING TRANSVERSE ARM
-concrete .ASSEMBLY
-v Bracket I=TRANSVERSE ARM I-BEAM CONNECTOR
(OOrxted8 with grade 5-11T x 2172-carriage bolt
&rMJq
E-w•Brace T lop(1.257 J=CONCRETE'V' BRACKET(connects with
Bottom (1.57 grade 5-1/2'x C-carriage bolt&nut)
' :Concrete
t FobW Runner
wall
I
Model # 1101 C "V'
i
OI.M TECHNOLOGIES} INC. Telephone:931-796-4555
1-800-284-7437 Fax:931-796-8811
www.o tiv a rte ch n o l og iea.co m
VERTICAL VINYL SKIRTING ( components a installation )
--.-WALL
�aCK
AT.TRG KEG VJITt4
-2k tryCH SCRBwS (io ADAR7
r
TOP Jr-RON-T FLOOR,
SiJAPS Ij3 ro 'TOp BAfJC
r
NIDE9 SCREWS AND PANEL
v TED PAWL
BLOCK S.,pPoFtT
3.9 m4K" PEe Fco-r
SEC�REb "(' dF UE?AK
OW
O 't'DP 6ACfAND
13DTTpM iZhtc.. yw SCXEwS
t{�"OLk { U
/g LL a�LS aQ6 A CCE S6j BiREMoVIN6 �P V-oZpNT 4s+n RUP ON PANELIE3 rroM T
A-rTACHCO TO GROuiul�
wt-r% 74/cq GAWkNi7E6 NAIL 19'0C:
CM SOIL IS SalloY'T�iEN QXa"ac�
Jul U" GU 1 R O: 'T 1 nl"1
Page 1 Residential Most Loss and Heat Gain Calculation T1712014
In a=rdance with ACCA Manual J
Report Prepared
IW-
Centmi Air Syslbsms Inc.
For: central homes
172 nettles
jensen beach,fl
Design Conditions: Fort Pierce
Indoor: Outdoor.
Summer temperature: 70 Summer temperature: 90
Winter temperature 70 Winter temperature: 42
Relative humidity: 55 Summer grains of moisture: 127
Daily temperature rangeA odium
Building Component Sensible Latent Tatal Total
Gain Gan Hest Gain Heat Loss
(STUN) (STUH) (BTU") (STUN)
Duct 0 0 0 0
Floors 1.055 0 1,055 1,893
Wails 1.888 0 1,888 2,240
Ceilings 2,008 0 2,008 1,562
People 1.200 920 2,120 0
Fireplaces 0 0 0 0
Misc 1,200 0 1,200 0
Windows 5,360 0 5,360 3,815
Doors _ 340 0 340 404
Glassdoors 0 0 0 0
Skylights 0 0 0 0
Infiltration 1,394 2,887 4,281 4,366
Whole House 14,455 3,807 18,262 14,280
(1.5 tons)