HomeMy WebLinkAboutAPPROVED Pinedo Energy CalcFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: RJM PINEDO RESIDENCE 2495
Builder Name: RJM BUILDERS
Street: HICKORY DRIVE
Permit Office: FT PIERCE
City, State, Zip: FT PIERCE, FL,
Permit Number:
Owner
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing
New (From Plans)
10. Wall Type$2740.0 sgft.)
Insulation 'Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R-4.1 2400.00 ftz
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=11.0 340.00 ftz
c. NIA
R= ftz
4. Number of Bedrooms
4
d. NIA
R= ftz
5. Is this a worst case?
Yes
11. Ceiling Types (2492.0 sgft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2492.00 ftz
6. Conditioned floor area above grade (ftz)
2492
b. N/A
R= ftz
Conditioned floor area below grade (ftz)
0
c. N/A
R= ftz
7. Windows(420.1 sgft.) Description
Area
12. Ducts
R ftz
a. U-Factor: Sgl, U=0.52
316.11 ftz
a. Sup: Attic, Ret: Attic, AH: Main
6 144
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=0.53
64.00 ftz
13. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.31
a. Central Unit
46.5 SEER:14.50
c. U-Factor: Dbl, U=0.52
40.00 ftz
SHGC: SHGC=0.30
Area Weighted Average Overhang Depth:
5.119 ft.
14. Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC:
0.302
a. Electric Heat Pump
46.5 HSPF:8.20
8. Skylights
Area
c. U-Factor:(AVG) N/A
ftz
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 50 gallons
9. Floor Types (2492.0 sqft.)
Insulation Area
EF:2.000
a. Slab -On -Grade Edge Insulation
R=0.0 2492.00 ftz
b. Conservation features
b. N/A
R= ftz
None
c. N/A
R= ftz
16. Credits
Pstat
Glass/Floor Area: 0.169
Total Proposed Modified Loads: 77.00
PASS
Total Baseline
Loads: 81.81
1 hereby certify that the plans and splacifications covered by
Review of the plans and
STg1�
this calculation are in compliance h the Florida Energ
specifications covered by this
O4�HE
Code.
calculation indicates compliance,,
=f:rs�•�. .,
r�
with the Florida Energy Code.
PREPARED BY:
Before construction is completed94
I
DATE:
this building will be inspected for
compliance with Section 553.908
', A
I hereby certify that this b II ' g, as designed, is in compliance
Florida Statutes.
u
♦�
with the Florida Energy
Cps WE
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
3/512021 9:06 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FORM R405-202n 1?dD11T CI [RARAAOV r+ucntii .....
•••,••• a� t W1 r r�crvR 1
PROJECT
Title:
RJM PINEDO RESIDENCE 2 Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 2492
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units:
1
Worst Case: Yes
PlatBcok:
Builder Name:
RJM BUILDERS
Rotate Angle: 270
Street:
HICKORY DRIVE
Permit Office:
FT PIERCE
Cross Ventilation:
County:
St, Lucie
Jurisdiction:
Family Type:
Detached
Whole House Fan:
City, State, Zip:
FT PIERCE,
New/Existing:
New (From Plans)
FL
Comment:
CLIMATE
Design
Location
Design Temp
TMY Site
Int Design Temp Heating
Design Daily Temp
97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
L,
Fort Pierce FL_VERO_BEACH _MUNI 39 90
70 75 299
62
Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2492 22428
SPACES
Number
Name
Area Volume Kitchen —Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2492 22428 Yes 8
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab
-On -Grade Edge Insulatio
Main 214 ft 0
2492 ft2
__--
0 0 1
ROOF
J #
Type
Roof Gable Roof
Red Solar SA Emitt
Emitt Deck Pitch
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Hip Composition shingles 2700 ft2 0 ftz Light
N 0.96 No 0.9
No 20 22.62
ATTIC
%
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Partial cathedral cei
Unvented 0 2492 ft2 N Y
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
Under Attic (Unvented)
Main 0 Blown
2492 ft2 0.11
Wood
3/5/2021 9:06 AM EnergyGauge& USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5
FORM R405-2020 INPUT SUMMARY CHFCKLtST RFPnRT
WALLS
Adjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar Below
s
AJakLe._.-EL_ln.....__
Fi
In
Araa
R_Value
Fraction
AbSotGtadejo
_ 1
N=>W Exterior
Concrete Block - Int Insul
Main
4.1
55
10
550.0 ft2
0
0,15
0
2
NE=>NW Exterior
Concrete Block - Int Insul
Main
4.1
9
10
90.0 ft2
0
0.15
0
_ 3
E=>N Exterior
Concrete Block - Int Insul
Main
4.1
54
10
540.0 ft2
0
0,15
0
4
SE=>NE Exterior
Concrete Block - Int Insul
Main
4.1
10
10
100.0 ft2
0
0.15
0
5
S=>E Exterior
Concrete Block - Int Insul
Main
4.1
31
10
310.0 ftz
0
0.15
0
6
SW=>SE Exterior
Concrete Block - Int Insul
Main
4.1
5
10
50.0 ftz
0
0.15
0
_ 7
W=>S Exterior
Concrete Block - Int Insul
Main
4.1
70
10
700.0 ft2
0
0.15
0
8
NW=>S Exterior
Concrete Block - Int Insul
Main
4.1
6
10
60.0 ftz
0
0.15
0
9
E=>N Garage
Frame - Wood
Main
11
8
10
80.0 ft2
0.5
0.15
0
10
S=>E Garage
Frame - Wood
Main
11
23
10
230.0 ft2
0.5
0.15
0
_ 11
W=>S Garage
Frame - Wood
Main
11
3
10
30.0 ft2
0.5
0.15
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1 S=>E
Insulated
Main
None
.46
6
8
48 ft2
2 S=>E
Insulated
Main
None
.46
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation
=>) changed to Worst Case.
/
Wall
Overhang
1/
# Ornt ID
Frame Panes NFRC
U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 N=>W 1
Metal Single (Tinted)
Yes
0.52
0.3
N
22.5 ft2
7 ft 0 in
1 ft 0 in
None
None
2 NE=>NW 2
Metal Single (Tinted)
Yes
0.52
0.3
N
33.3 ft2
8 It 0 in
1 ft 0 in
None
None
3 N=>W 1
Metal Single (Tinted)
Yes
0.53
0.31
N
64.0 ft2
10 ft 0 in
1 ft 0 €n
None
None
4 W=>S 7
Metal Single (Tinted)
Yes
0.52
0.3
N
10.0 ft2
16 ft 0 in
1 ft 0 in
None
None
5 NW=>SW 8
Metal Single (Tinted)
Yes
0.52
0.3
N
10.0 ft2
5 ft 0 in
1 ft 0 in
None
None
6 N=>W 1
Metal Single (Tinted)
Yes
0.52
0.3
N
10.0 ft2
8 ft 0 in
1 ft 0 in
None
None
7 W=>S 7
Metal Single (Tinted)
Yes
0.52
0.3
N
64.0 ftz
5 ft 0 in
1 ft 0 in
None
None
8 N=>W 1
Metal Single (Tinted)
Yes
0.52
0.3
N
45.0 ft2
1 ft 0 in
1 ft 0 in
None
None
9 W=>S 7
Metal Single (Tinted)
Yes
0.52
0.3
N
17.8 ft2
1 ft 0 in
1 ft 0 in
None
None
10 E=>N 3
Metal Single (Tinted)
Yes
0.52
0.3
N
12.0 ft2
1 ft 0 in
1 ft 0 in
None
None
11 E=>N 3
Metal Single (Tinted)
Yes
0.52
0.3
N
30.0 ft2
1 ft 0 in
1 ft 0 in
None
None
12 SE=>NE 4
Metal Single (Tinted)
Yes
0.52
0.3
N
6.0 ft2
1 ft 0 in
1 ft 0 in
None
None
13 S=>E 5
Metal Single (Tinted)
Yes
0.52
0.3
N
22.5 ft2
1 ft 0 in
1 ft 0 in
None
None
14 S=>E 5
Metal Single (Tinted)
Yes
0.52
0.3
N
18.0 ftz
16 ft 0 in
1 ft 0 in
None
None
15 S=>E 5
Metal Single (Tinted)
Yes
0.52
0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
16 SE=>NE 4
Metal Double (Clear)
Yes
0.52
0.3
N
10.0 ft2
1 ft 0 in
1 ft 0 in
None
None
17 SW=>SE 6
Metal Double (Clear)
Yes
0.52
0.3
N
10.0 ft2
1 ft 0 in
1 ft 0 in
None
None
18 SW=>SE 6
Metal Double (Clear)
Yes
0.52
0.3
N
20.0 ftz
1 ft 0 in
1 ft 0 in
None
None
3/512021 9:06 AM EnergyGauge® USA 7,0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 IMPI IT CI IRAIIAADV r1UCr1vi rc-r oin-nr%nT
..L-I Vf\
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
420 ft'
420 ft'
64 It loft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2616.6 143.55 269.51 .1324 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
None
Singl HSPF:8.2 46.5 kBtu/hr 1
Sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
None
Singl SEER: 14.546.5 kBtu/hr 1395 cfm 0.75 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric Heat Pump
Garage
2 50 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
DUCTS
#
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 144 ft'
Attic
41 ft' Default Leakage Main (Default) (Default)
1 1
3/5/2021 9:06 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INP11T Sl1MMAPV r_141=r-W1 ICT M�OnOr
TEMPERATURES
Programable Thermostat:
Y
Ceiling Fans:
Coolin [ ] Jan
Feb
EX�
[ j Mar
f
Apr
Ma [X] Jun
X Jul
X AugX
Se
Oct
j ] Nov j
j Dec
Heating 4X] Jan
Ventin j Jan
Feb
[[ Feb
{X] Mar
((Xj Mar
[X
Apr
A r
iMayj
i
jJun
May [ ] Jun
4 � JuI
[ Jul
4 Au[
( Aug
Sep
( Se
Oct
Oct
[X] Nov [X]
[X] Nov [
Dec
] Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78
76
78
78
80
80
80
80
PM
80
80
78
78 78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78 78
78
78
78
78
78
78
78
PM
78
78
78
78 78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66
68
68
68
68
68
68
68
PM
68
68
68
68 68
66
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66
68
68
68
68
68
68
68
PM
68
68
68
68 68
68
68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM
Fan Watts HRV
Heating System
Run Time Cooling System
None
0
0
0 1 - Electric Heat Pump
0%
1 - Central Unit
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ft2
Oft
0.3
Main
3/5/2021 9:06 AM EnergyGaugeV USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
FJVW1
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the
Residential Simulated Performance Alternative shall include:
�r , checklist
❑ Form R405-2020 report
t,❑ Input summary checklist that can be used for field verification (usually four pages/may be greater)
Energy Performance Level (EPL) Display Card (one page)
4V-AC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
i11 Mandatory Requirements (five pages)
Required prior to CO:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1. 9 - one page)
❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4
allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to
comply with Section C402,5
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
2020 Duct Leakage Test Report - Performance Method (usually one page)
315/2021 9:06:21 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1