Loading...
HomeMy WebLinkAboutAPPROVED Pinedo Energy CalcFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: RJM PINEDO RESIDENCE 2495 Builder Name: RJM BUILDERS Street: HICKORY DRIVE Permit Office: FT PIERCE City, State, Zip: FT PIERCE, FL, Permit Number: Owner Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type$2740.0 sgft.) Insulation 'Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R-4.1 2400.00 ftz 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 340.00 ftz c. NIA R= ftz 4. Number of Bedrooms 4 d. NIA R= ftz 5. Is this a worst case? Yes 11. Ceiling Types (2492.0 sgft.) Insulation Area a. Roof Deck (Unvented) R=20.0 2492.00 ftz 6. Conditioned floor area above grade (ftz) 2492 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 7. Windows(420.1 sgft.) Description Area 12. Ducts R ftz a. U-Factor: Sgl, U=0.52 316.11 ftz a. Sup: Attic, Ret: Attic, AH: Main 6 144 SHGC: SHGC=0.30 b. U-Factor: Sgl, U=0.53 64.00 ftz 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.31 a. Central Unit 46.5 SEER:14.50 c. U-Factor: Dbl, U=0.52 40.00 ftz SHGC: SHGC=0.30 Area Weighted Average Overhang Depth: 5.119 ft. 14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.302 a. Electric Heat Pump 46.5 HSPF:8.20 8. Skylights Area c. U-Factor:(AVG) N/A ftz 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 50 gallons 9. Floor Types (2492.0 sqft.) Insulation Area EF:2.000 a. Slab -On -Grade Edge Insulation R=0.0 2492.00 ftz b. Conservation features b. N/A R= ftz None c. N/A R= ftz 16. Credits Pstat Glass/Floor Area: 0.169 Total Proposed Modified Loads: 77.00 PASS Total Baseline Loads: 81.81 1 hereby certify that the plans and splacifications covered by Review of the plans and STg1� this calculation are in compliance h the Florida Energ specifications covered by this O4�HE Code. calculation indicates compliance,, =f:rs�•�. ., r� with the Florida Energy Code. PREPARED BY: Before construction is completed94 I DATE: this building will be inspected for compliance with Section 553.908 ', A I hereby certify that this b II ' g, as designed, is in compliance Florida Statutes. u ♦� with the Florida Energy Cps WE OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 3/512021 9:06 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5 FORM R405-202n 1?dD11T CI [RARAAOV r+ucntii ..... •••,••• a� t W1 r r�crvR 1 PROJECT Title: RJM PINEDO RESIDENCE 2 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2492 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBcok: Builder Name: RJM BUILDERS Rotate Angle: 270 Street: HICKORY DRIVE Permit Office: FT PIERCE Cross Ventilation: County: St, Lucie Jurisdiction: Family Type: Detached Whole House Fan: City, State, Zip: FT PIERCE, New/Existing: New (From Plans) FL Comment: CLIMATE Design Location Design Temp TMY Site Int Design Temp Heating Design Daily Temp 97.5 % 2.5 % Winter Summer Degree Days Moisture Range L, Fort Pierce FL_VERO_BEACH _MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2492 22428 SPACES Number Name Area Volume Kitchen —Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2492 22428 Yes 8 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 214 ft 0 2492 ft2 __-- 0 0 1 ROOF J # Type Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2700 ft2 0 ftz Light N 0.96 No 0.9 No 20 22.62 ATTIC % V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Partial cathedral cei Unvented 0 2492 ft2 N Y CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type Under Attic (Unvented) Main 0 Blown 2492 ft2 0.11 Wood 3/5/2021 9:06 AM EnergyGauge& USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHFCKLtST RFPnRT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below s AJakLe._.-EL_ln.....__ Fi In Araa R_Value Fraction AbSotGtadejo _ 1 N=>W Exterior Concrete Block - Int Insul Main 4.1 55 10 550.0 ft2 0 0,15 0 2 NE=>NW Exterior Concrete Block - Int Insul Main 4.1 9 10 90.0 ft2 0 0.15 0 _ 3 E=>N Exterior Concrete Block - Int Insul Main 4.1 54 10 540.0 ft2 0 0,15 0 4 SE=>NE Exterior Concrete Block - Int Insul Main 4.1 10 10 100.0 ft2 0 0.15 0 5 S=>E Exterior Concrete Block - Int Insul Main 4.1 31 10 310.0 ftz 0 0.15 0 6 SW=>SE Exterior Concrete Block - Int Insul Main 4.1 5 10 50.0 ftz 0 0.15 0 _ 7 W=>S Exterior Concrete Block - Int Insul Main 4.1 70 10 700.0 ft2 0 0.15 0 8 NW=>S Exterior Concrete Block - Int Insul Main 4.1 6 10 60.0 ftz 0 0.15 0 9 E=>N Garage Frame - Wood Main 11 8 10 80.0 ft2 0.5 0.15 0 10 S=>E Garage Frame - Wood Main 11 23 10 230.0 ft2 0.5 0.15 0 _ 11 W=>S Garage Frame - Wood Main 11 3 10 30.0 ft2 0.5 0.15 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S=>E Insulated Main None .46 6 8 48 ft2 2 S=>E Insulated Main None .46 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation =>) changed to Worst Case. / Wall Overhang 1/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>W 1 Metal Single (Tinted) Yes 0.52 0.3 N 22.5 ft2 7 ft 0 in 1 ft 0 in None None 2 NE=>NW 2 Metal Single (Tinted) Yes 0.52 0.3 N 33.3 ft2 8 It 0 in 1 ft 0 in None None 3 N=>W 1 Metal Single (Tinted) Yes 0.53 0.31 N 64.0 ft2 10 ft 0 in 1 ft 0 €n None None 4 W=>S 7 Metal Single (Tinted) Yes 0.52 0.3 N 10.0 ft2 16 ft 0 in 1 ft 0 in None None 5 NW=>SW 8 Metal Single (Tinted) Yes 0.52 0.3 N 10.0 ft2 5 ft 0 in 1 ft 0 in None None 6 N=>W 1 Metal Single (Tinted) Yes 0.52 0.3 N 10.0 ft2 8 ft 0 in 1 ft 0 in None None 7 W=>S 7 Metal Single (Tinted) Yes 0.52 0.3 N 64.0 ftz 5 ft 0 in 1 ft 0 in None None 8 N=>W 1 Metal Single (Tinted) Yes 0.52 0.3 N 45.0 ft2 1 ft 0 in 1 ft 0 in None None 9 W=>S 7 Metal Single (Tinted) Yes 0.52 0.3 N 17.8 ft2 1 ft 0 in 1 ft 0 in None None 10 E=>N 3 Metal Single (Tinted) Yes 0.52 0.3 N 12.0 ft2 1 ft 0 in 1 ft 0 in None None 11 E=>N 3 Metal Single (Tinted) Yes 0.52 0.3 N 30.0 ft2 1 ft 0 in 1 ft 0 in None None 12 SE=>NE 4 Metal Single (Tinted) Yes 0.52 0.3 N 6.0 ft2 1 ft 0 in 1 ft 0 in None None 13 S=>E 5 Metal Single (Tinted) Yes 0.52 0.3 N 22.5 ft2 1 ft 0 in 1 ft 0 in None None 14 S=>E 5 Metal Single (Tinted) Yes 0.52 0.3 N 18.0 ftz 16 ft 0 in 1 ft 0 in None None 15 S=>E 5 Metal Single (Tinted) Yes 0.52 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 16 SE=>NE 4 Metal Double (Clear) Yes 0.52 0.3 N 10.0 ft2 1 ft 0 in 1 ft 0 in None None 17 SW=>SE 6 Metal Double (Clear) Yes 0.52 0.3 N 10.0 ft2 1 ft 0 in 1 ft 0 in None None 18 SW=>SE 6 Metal Double (Clear) Yes 0.52 0.3 N 20.0 ftz 1 ft 0 in 1 ft 0 in None None 3/512021 9:06 AM EnergyGauge® USA 7,0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5 FORM R405-2020 IMPI IT CI IRAIIAADV r1UCr1vi rc-r oin-nr%nT ..L-I Vf\ GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 420 ft' 420 ft' 64 It loft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 2616.6 143.55 269.51 .1324 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None Singl HSPF:8.2 46.5 kBtu/hr 1 Sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None Singl SEER: 14.546.5 kBtu/hr 1395 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump Garage 2 50 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None DUCTS # ---- Supply ---- Location R-Value Area ---- Return ---- Air CFM 25 CFM25 HVAC # Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 144 ft' Attic 41 ft' Default Leakage Main (Default) (Default) 1 1 3/5/2021 9:06 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 5 FORM R405-2020 INP11T Sl1MMAPV r_141=r-W1 ICT M�OnOr TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin [ ] Jan Feb EX� [ j Mar f Apr Ma [X] Jun X Jul X AugX Se Oct j ] Nov j j Dec Heating 4X] Jan Ventin j Jan Feb [[ Feb {X] Mar ((Xj Mar [X Apr A r iMayj i jJun May [ ] Jun 4 � JuI [ Jul 4 Au[ ( Aug Sep ( Se Oct Oct [X] Nov [X] [X] Nov [ Dec ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 76 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 66 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 - Electric Heat Pump 0% 1 - Central Unit MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 Oft 0.3 Main 3/5/2021 9:06 AM EnergyGaugeV USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5 FORM R405-2020 FJVW1 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2020 Florida Building Code, Energy Conservation via the Residential Simulated Performance Alternative shall include: �r , checklist ❑ Form R405-2020 report t,❑ Input summary checklist that can be used for field verification (usually four pages/may be greater) Energy Performance Level (EPL) Display Card (one page) 4V-AC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 i11 Mandatory Requirements (five pages) Required prior to CO: ❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1. 9 - one page) ❑ A completed 2020 Envelope Leakage Test Report (usually one page); exception in R402.4 allows dwelling units of R-2 Occupancies and multiple attached single family dwellings to comply with Section C402,5 ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed 2020 Duct Leakage Test Report - Performance Method (usually one page) 315/2021 9:06:21 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1