HomeMy WebLinkAboutAPPROVED Doole gas tank specsHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
October 1, 2020
Como Oil Company - Vero
5102 South Cant Road
Dululth, MN 55804
Re: 500 Gallon Underground Tank
Doole Residence
124 Queen Isabella Court
Hutchinson Island, Florida
KSM Project #: 204806-lpgas
Dear Sir:
Mailing
P.O. Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A. # 5693
KSMengineering.net
Please see attached detail for how to tie down the 500 gallon underground tank at the
referenced site. The following are general notes concerning the attached drawing.
1. Prior to installing the earth augers, check for underground utilities.
2. Earth auger and cables shown are designed to resist buoyancy forces from an
empty tank fully submerged.
3. Earth augers type and length is dependent of Soil Class. For this site soil is
assumed as Class 4 Soil. If the onsite soils are not Class 4, engineer is to be
notified.
4. Earth auger shall have a tested minimum pull out value of 3000 lbs.
5. Location of tanks are dependent on local codes and are the responsibility of the
persons obtaining the permit.
If you have any questions, please feel free to contact the office.
Respectfully,
\��`�J�J ........
Digitally
��1.' �,�CENS� •.� 'i
by Julie
-
i
No. 68366 .-
This item has been elect ronicallysigned and
sealed by Julie Keller, P.E. FI. Lic. 68366 on
signed
1 •• 1 =
7C * 7C
the date stated directly to the right using a
digital signature.
Keller
Julie E. Keller, P.E.
06 a `- ',`
O* v�
Printed copies of this document are not
consideredsigned and sealed and the
Date:
President
- Q STATE OF L(/
i,��' •,FLORID p!•'•-`�`�
signature must be verified on any electronic
copies.
1 1
2020. 10.0 1
P.E. # 68366
''�`,rSIpNA1. Et
08:34:29-04'00'
J EK/cv
GROUND LEVEL
\\ \\ \\ \ \ 1/4" GALVANIZED VINYL COATED
500 GAL. WIRE ROPE W/ CABLE CLAMP,
(2 REQUIRED)
\\ \\ \\ LP GAS \
TANK /
5/8" x 48" TRAILER ANCHOR
WITH 6" HELIX (4 REQUIRED)
GROUND LEVEL
�,
\ 1/4" GALVANIZED VINYL
COATED WIRE ROPE
\/ 500 GAL. 2 REQUIRED
\ LP GAS 5/8" TRAILER ANCHOR
\ TANK WITH 6" HELIX, 4 REQUIRED
PROJECT: COMO OIL: Doole Residence 124 Queen Isabella CourtHutchinson Island Florida
SHEET 1 OF 1 DRAWN BY: C.V.
AN ENGINEERING DESIGNED BY: J.K.
PROJECT N0.:204806-7 LVL AND TESTING DATE:1010112020
,L% L
SCALE: NONE