Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED Drawings_Lindsay_Permit
f;r I UNIT."B" Existing Floor Plan Floor plan for Unit "C" Renovation of Master Bath and Guest Bath All work to conform to FBC 2020 7th Edition C Cooke Construction, Inc. Scope of Work Job: Lindsay Bathrooms Renovation Division Remodel 2 bathrooms CGC1520585 Owner: Lindsay Date: June 8, 2021 1276 Business Park Place Phone: (772) 530-0659 Address: 8600 S Ocean Dr #1004 Drawn By: Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Jensen Beach, FL Sheet #: 1 of 7 Existing Floor Plan L ol New Floor Plan Elevations Scope of Work: Remove and replace vanity. Include new top, faucets, and sink. Same location Remove tub and walls around tub. Remove Shower pan and shower walls Frame for new shower to be larger and incorporate tub floor space Install new shower valve Install new shower using WEDI shower system. Using existing drain locations Install new shower panels using safety glass enclosure Install new toilet at same location Install new exhaust fan, same location as existing Install new recess lights lights using existing vanity light switch leg / If needed update and/or relocate GFCI outlets to code f All work to conform to FBC 2020 7th Edition C Cooke Construction, Inc. Scope of Work Job: Lindsay Bathrooms Renovation Division Remodel 2 bathrooms CGC1520585 Owner: Lindsay Date: June 8, 2021 1276 Business Park Place Phone: (772) 530-0659 Address: 8600 S Ocean Dr #1004 Drawn By: Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Jensen Beach, FL Sheet #: 2 of 7 Existing Floor Plan 1 � �f I 4 � � r Scope of Work: Remove and replace vanity. Include new top, faucets, and sink. Same location Remove tub and walls around tub. Install new shower valve Install new shower with curb using WEDI shower system. Same location Install new shower doors using safety glass enclosure Install new toilet at same location Install new exhaust fan, same location as existing Install new recess lights and sconce lights using existing vanity light switch leg If needed update and/or relocate GFCI outlets to code All work to conform to FBC 2020 7th Edition New Floor Plan Vanity Elevation Shower Elevation C Cooke Construction, Inc. Scope of Work Job: Lindsay Bathrooms Renovation Division Remodel 2 bathrooms CGC1520585 Owner: Lindsay Date: June 8, 2021 1276 Business Park Place Phone: (772) 530-0659 Address: 8600 S Ocean Dr #1004 Drawn By: Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Jensen Beach, FL Sheet #: 3 of 7 Existing firewall between units located in master bathroom matches the design below There is no plan to distrub or penetrate the existing firewall but if wall is found to be compromised from previous renovation then it will be repaired as the the diagram below to match what is existing. WALLS AND INTERIOR PARTITIONS, NONCOMBUSTIBLE GA FILE NO. WP 1524 I I PROPRIETARY- I GYPSUM WALLBOARD, STEEL STUDS Base layer 5!'s" proprietary type X gypsum wallboard or gypsum veneer base applied at right angles to each side of 351s" steel studs 24" ❑.c. with 1" Type S drywall screws 16" O.G. Face layer '-la" proprietary type X gypsum wallboard or gypsum veneer base applied at right angles to each side with 15/a" Type 3 drywall screws 16" o.c. Face layer horizontal joints offset not less than 12" from base layer horizontal joints_ Horizontal joints on opposite sides need not be staggered or backed. Sound tested with 3112" glass fiber insulation in stud cavity. (NLB) PROPRIETARY GYPSUM BOARD CertainTeed Gypsum Inc. - 51a" ProRoc. Type K Gypsum Panels 2 HOUR FIRE 55 to 59 STC SOUND Thickness- 611a" Approx. Weight: 10 psf Fire Test- UL R3660, 07NK21428, 2-14-08, UL Design U411 Sound Test: NGC 2006049, 1-31-07 All work to conform to FBC 2020 7th Edition C Cooke Construction, Inc. Scope of Work Job: Lindsay Bathrooms Renovation Division Remodel 2 bathrooms CGC1520585 Owner: Lindsay Date: June 8, 2021 1276 Business Park Place Phone: (772) 530-0659 Address: 8600 S Ocean Dr #1004 Drawn By: Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Jensen Beach, FL Sheet #: 4 of 7 ICC-ES PMG Product Certificate PMG-1189 M1 Effective Date: May 2021 This listing is subject to re-examination in one year. www.icc-es-pmq.org 1 (800) 423-6587 1 (562) 699-0543 A Subsidiary of the International Code Council° CSI: DIVISION: 22 00 00—PLUMBING Section: 22 40 00—Plumbing Fixtures (Shower System Kit) Product certification system: The ICC-ES product certification system includes testing samples taken from the market or supplier's stock, or a combination of both, to verify compliance with applicable codes and standards. The system also involves factory inspections, and assessment and surveillance of the supplier's quality system. Product: wedi Fundo Shower System and Tile Backer Board Underlayments Listee: wedi Corporation 1160 Pierson Drive, Suite 102 Batavia, IL 60510 www.wedicorp.com Compliance with the following codes: 2021, 2018, 2015, 2012 and 2009 International Plumbing Code° (I PC) 2021, 2018, 2015, 2012 and 2009 International Residential Code° (I RC) 2021, 2018, 2015, 2012 and 2009 International Building Code° (IBC) 2018, 2015, 2012 and 2009 National Standard Plumbing Code° (NSPC) 2021, 2018, 2015, 2012 and 2009 Uniform Plumbing Code° (UPC)* 2015, 2010 and 2005 National Plumbing Code of Canada** 'Uniform Plumbing Code is a copyrighted publication if the International Association of Plumbing and Mechanical Officials ** National Plumbing Code of Canada is a copyrighted publication of National Research Council Canada Compliance with the following standard: ANSI Al18.10-2020, Load Bearing, Bonded, Waterproof Membranes for Thin -Set Ceramic Tile and Dimension Stone Installations ASME Al 12.6.3-2019, Floor and Trench Drains ASTM E 96-2016, Standard Test Methods for Water Vapor Transmission of Materials ASTM E 331-00(R16), ASTM E331-00(2016) Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference ICC-ES EG 159, Evaluation Guideline for Composite Backer Board (Approved Dec 2004) ICC-ES AC 71, Acceptance Criteria for Foam Plastic Sheathing Panels Used as Water Resistive Barriers (Approved Feb 2003, Ed Revised Nov 2018) IAPMO PS 46-2012, Field -Fabricated Tiling Kits IAPMO PS 106-2015el, Tileable Shower Receptors and Shower Kits Listings are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the listing or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this listing, or as to any product covered by the listing. Copyright © 2021 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 2 PMG-1189 1 Most Widely Accepted and Trusted Page 2 of 2 Identification: Installation: Models: Packaging label for each system shall include the manufacturer's name or trademark as well as the ICC-ES PMG certification mark. The wedi Fundo Shower Systems shall be installed in accordance with the manufacturer's published instructions and the applicable code(s). The wedi Fundo Shower system components shall be assembled and can be customized in the field. When provided drains must comply with ASME Al 12.18.2/CSA B125.2 as applicable. The wedi pre - sloped, ready -to -tile shower bases may be used in lieu of a CSA B45.5/IAPMO Z124 plastic shower receptors or any liner based shower installations. The wedi drain units do not require weep holes. The wedi Fundo Shower Systems consist of the following: a) The wedi waterproof Fundo shower bases are waterproof, pre -sloped, ready -to -tile floor units. The shower bases with linear and point drainage include factory sealed parts integrated into the floor base and can be installed with or without curbs in recessed, barrier free installations b) The wedi waterproof building panels which are engineered as a general purpose backer board and underlayment for tile as well as an integral part of the Fundo shower system and consist of a rigid extruded polystyrene foam covered on both sides with a cement -based resin surface and reinforcing mesh for durability and bond performance with tile adhesives. c) The wedi Vapor 85 Building Panel which may be used with or without wedi shower systems. It is a specialized building panel featuring the original wedi Building Panel but with its vapor exposed side protected by wedi Subliner Dry. The wedi Vapor 85 was tested to ASTM E96 Procedure E as a complete assembly with the wedi 620 joint sealing membrane and wedi Subliner Dry sealing tape over seams and fastener points and was found to have a perm rating of 0.03 perms which meets the permeance rating requirement of 0.5 perm or less and can be used in continuous use steam shower/room applications without additional vapor retarders in accordance with Tile Council of North America (TCNA) 2014 Handbook for Ceramic Glass and Stone Tile Installation (SR613-14 and SR614-14). d) The wedi waterproof Fundo Shower system accessories which may include the following waterproof components: wedi presloped curbs, wedi niches, wedi seats, wedi benches, wedi ADA compliant ramps, wedi vapor barrier for steam room installations, wedi fasteners, wedi drain cover plates, wedi sealants, wedi Fundo drains, wedi Subliner sheet waterproofing membrane system and tapes, with Subliner Dry Bonding Flange drain, wedi Subliner Dry Tub Sealing Tape. The wedi Fundo family line includes the following: Primo, Riolito Neo, Riolito Neo Modular, Riofino, Discreto, Ligno and Onestep. The wedi Fundo Shower system components and assembly for shower installations were proven to be waterproof, water-resistant, and mold resistant when tested in accordance with Al 18.10-2014 and ASTM E331. The wedi drains have found to comply with ASME Al 12.18.2/CSA B125.2 and do not require weep holes. Conditions of Listing: 1. The wedi Fundo Shower Systems, Building Panels and System Accessories shall be installed in accordance with the manufacturer's published instructions and the applicable code(s). 2. The wedi Fundo Shower Systems are under a quality control program with annual surveillance inspections by ICC-ES. ... wedf. • The blue XPS core is 100% waterproof and remains fully functional. • wedi Building Panels can he safely adhered and sealed in assembly using wedi joint Sealant: strong reinforcement, bond and waterproofing with virtually no build up as with conventional taping. • wedi Building Panels reinforced cement resin surface offers a superior bond surface to virtually any file and stone adhesive. No delamination, no surprises. • AlI building panel systems have great heat insulation properties. save energy costs and provide long-term protection against mold due to its inorganic nature and ability to safely water- proof. atension Collar Plastic Frame L -A L -A 100% Water Proof with Fastest Installation of Water- Easy and Sate Modu3ar Ma�ufatturers Ova rantee proof, Custom Tiled Showers in Instal€atian the Industry -undo Shower Base wedi Joint 5ealant L L Multiple CustomUable Natural Proterdon Ready to Tile Upon Product sizes Against Mold Installation Any Sim Tile and Stone