HomeMy WebLinkAboutEnergy CodeFORM R405-2020
FLORIDA ENERGY: EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method'
Project Name: Lot 114 Block 5 Waterstone 1820 CRGL
Builder Name:: ADAMS HOMES
Street: 5310 San Benedetto Place
Permit Office:
-City, State, Zip: Fort.Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO. INTL
County: St.. Lucie (Florida Climate Zone 2 )
1: New construction or existing' New (From Plans)
10.: Wall Type02120 0 sgft.) .
Insulation Area
2: Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1785.00 ftZ
b. Frame - Wood, Adjacent
R=13.0 270.00 ftZ
3. Number of units, if multiple family 1
c. Frame,: Wood, Exterior
R=13.0 65.00 ftZ
4. Number of Bedrooms 4
d. N/A
R= ftZ
51 Is this a worst case?. No
11. Ceiling Types (1900.0 sgft.)
Insulation.'. - Area
a: Under Attic (Vented) .
R=30.0 :1820.00 ftZ
6. Conditioned floor area above grade (ftZ) 1820
b. Knee WaI (Vented)
R=19.0 80,00 ftZ
Conditioned floor area below grade;(ftZ) 0
c. N/A
R= ftZ
7. Windows(239.3 sqft.) Description Area
12: Ducts
R ftZ
a.: U-Factor: Dbl, U=0.33 136.36 ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 364
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 32.38 ftZ
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHG6=0.21
a. Central Unit
:35.0 SEER:16.00
c. U-Factor: Dbl, U=0.30 32.38 ftZ
SHGC: SHGC=0.23
Area Weighted Average Overhang.Depth' 4.251 ft.
14. Heating systems
a. Electric Heat Pump
kBtu/hr Efficiency,
34.6 HSPF:8.50
Area Weighted Average SHGC: 0.269
8. Skylights Area
c. U-Factor:(AVG) N/A ftZ
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. Floor Types (1820.0 sgft.) Insulation Area
a
EF: 0.940
a. Slab -On -Grade: Edge Insulation R=0.0 1820.00 ftZ
b: Conservation features,
b. N/A R= ftZ
None
c. N/A R= ftZ
16. Credits
Pstat
Total Proposed Modified Loads: 59:57
Glass/Floor Area: 0.131
A C
PASS"
Total Baseline Loads... 64.64
I hereby certify that the plans ications covered
e w of the Mans
and
T ST
this calculation are in comp' n h the Flori ergy
specifications covered
by this
p�
Code.
calculation indicates
compliance
with the.Flodda
Energy Code.
PREPARED BY:
Before construction
is completed
r �i
DATE: n4.1 s_2n91 Winn Kemmnny
this building wile
be inspected for
compliance with
Section 553:908
"
I hereby certify that this building, as designed, is in compliance
Florida Statute.
with the Florida E e.
GODa
OWN ER/^^E
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance: with R403.3.2.1.
compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
` envelope leakage test report with envelope leakage. no greater than 7.00 ACH50 (R402.4.1.2).
4/15/2021 11:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2C20) Compliant Software Page 1 of 4 .
FORM R405-2020 INPUT SUMMARY CHFICI(I IST R1=pnRT
PROJECT
Title:
Lot 114 Block 5 Waterstone 1 Bedrooms: 4
Address Type:
Lot Information
r Building Type:
User
Conditioned Area: 1820
Lot #
114-5
Owner Name:
Total Stories: 1
Block/Subdivision:
Waterstone
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
ADAMS HOMES
Rotate Angle: 0
Street:
5310 San Benedetto PI
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
661000
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type:
Detached
FL, 34951
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site 97.5 % 2.5 %
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299
58 Medium
BLOCKS
Number
Name
Area Volume
1
Blocki
1820 18200
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
1820 18200 Yes 5
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 33 ft 0 1820 ft2 ----
0.42 0 0.58
ROOF
i
/
Roof Gable Roof
Rad Solar SA Emitt
Emitt Deck Pitch
V/ #
Type
Materials Area Area Color
Barr Absor. Tested
Tested Insul. (deg)
1
Gable or Shed Composition shingles 2035 ft2 456 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
V #
Type
Ventilation Vent Ratio (1 in) Area
RBS IRCC
1
Full attic
Vented 300 1820
ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1820 ft2 0.11
Wood
2
Knee Wall (Vented)
Main 19 Blown
80 ft2 0.11
Wood
4/15/2021 11:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 4
f
FORM R405-2020 INPUT SUMMARY CHECKLIST RFPC�RT
WALLS
Adjacent
Space
Cavity Width
Height
Sheathing Framing
Solar Below
1 NE
Exterior
Concrete Block - Int Insul
Main
4.1 59
0
10
0
590.0 ft2
0
0
0.6
0
2 NW
Exterior
Concrete Block - Int Insul
Main
4.1 13
6
10
0
135.0 ft2
0
0
0.6
0
3 SW
Exterior
Concrete Block - Int Insul
Main
4.1 66
0
10
0
660.0 ft2
0
0
0.6
0
4 SE
Exterior
Concrete Block - Int Insul
Main
4.1 40
0
10
0
400.0 ft2
0
0.6
0
5 -
Garage
Frame - Wood
Main
13 27
0
10
0
270.0 ft2
0
0.23
0.01
0
6 NW
Exterior
Frame - Wood
Main
13 6
6
10
65.0 ft2
0.23
0.6
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NW
Insulated I
Main
None
25
3
8
20 ft2
2
Wood
Main
None
.25
2
8
16
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SW 3
Vinyl Low-E Double
Yes
0.33 0.23
N
6.9
ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
2
NE 1
Vinyl Low-E Double
Yes
0.33 0.23
N
4I
.6 ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
3
NW 6
Vinyl Low-E Double
Yes
0.33 0.31
N
i.1
ft2
9 ft 4 in
0 ft 0 in
None
None
4
NW 2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2
ft2
1 ft 4 in
1 ft 0 in
None
None
5
NW 2
Vinyl Low-E Double
Yes
0.33 0.21
N
16.2
ft2
1 ft 4 in
1 ft 0 in
None
Exterior 5
6
NW 6
Vinyl Low-E Double
Yes
0.33 0.31
N
13.3
ft2
9 ft 4 in
1 ft 6 in
None
None
7
SW 3
Vinyl Low-E Double
Yes
0.33 0.23
N
48:6
ft2
1 It 4 in
0 ft 10 in
None
Exterior 5
8
SE 4
Vinyl Low-E Double
Yes
0.55 0.7
N
17.8
ft2
12 ft 0 in
0 ft 6 in
None
None
9
SE 4
Vinyl Low-E Double
Yes
0.3 0.23
N
32.4
ft2
1 ft 4 in
0 ft 10 in
None
Exterior 5
10
SE 4
Vinyl Low-E Double
Yes
0.33 0.23
N
32.4
ft2
I
12 ft 0 in
0 ft 6 in
None
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg.
Wall Height
Exposed Wall Insulation
1
596 ft2 596 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .0004414
2123.3 116.49
218.7
.1381
7
4/15/2021 11:29 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020)I Compliant Software Page 3 of 4
4
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency,, Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity,
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 16
35 kBtu/hr
cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap IUse
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
I
FSEC
Cert # Company Name
System Model # Collector
Collector
Model # Area
Storage
Volume
FEF
None None
ftZ
DUCTS
/ ---- Supply ----
�/ # Location R-Value Area
---- Return ---
Location Area Leakage Type
Air
Handler
CFM 25 CFM25
TOT OUT QN
RLF
HVAC #
Heat Cool
1 Attic
6 364 ftz
Main
91 ftZ Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Cooling ]Jan ] Feb
Heating f X] Jan f X] Feb
Venting [ j Jan [ j Feb
Mar
Mar
X Mar
Ceiling Fans:
Jul
f APr f Mayf Jun Jul
Apr May X Jun ri
[X] A r [ Ma [ Jun Jul
AuSeP
rl Aug
Aug
Se
P Se [X]
Oct
Oct
Oct
Nov
Nov
X Nov
Dec
Dec
Dec
Thermostat Schedule: HERS 2006 Reference
Schedule Type 1
2 3
Hours
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
PM
Cooling (WEH) AM
PM
Heating (WD) AM
PM
Heating (WEH) AM
PM
78
80
78
78
66
68
66
68
78 78
80 78
78 78
78 78
66 66
68 68
66 66
68 68
78 78 78
78 78 78
78 78 78
78 78 78
66 66 68
68 68 68
66 66 68
68 68 68
MASS
78
78
78
78
68
68
68
68
78 80
78 78
78 78
78 78
68 68
68 68
68 68
68 68
80
78
78
78
68
68
68
68
80
78
78
78
68
66
68
66
80
78
78
78
68
66
68
66
Mass Type
Area
Thickness Furniture
Fraction Space
Default 8 Ibs/s .ft.
0 ftZ
0 ft
0.3
Main
4/15/2021 11:29 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (20201) Compliant Software Page 4 of 4
�I ,A
FORM R405-2020
ENERGY PERFORMANCE LEVEL EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the EnergyPerformance Index, the more efficient the home
5310 San Benedetto Place, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul,:Exterior
R=4.1
1785.00 ft2
b. Frame - Wood, Adjacent
R=13.0
270.00 ft2
3. Number of units, if multiple family
1
c. Frame - Wood, Exterior
R=13.0
65.00 ft2
4. Number of Bedrooms
4
d. N/A
R=
ft2
5: Is this
11. Ceiling Type and insulation level
Insulation
Area
a worst case?
No
a. Under Attic (Vented)
R=30.0
1820.00 ft2
6. Conditioned floor area (ft2)
1820
b. Knee Wall (Vented)
R=19.0
80.00 ft2
7. Windows** Description
Area
c. N/A
R=
ft2
a. U-Factor: Dbl, U=0.33
-
136.36 ft2
12. Ducts, location & insulation level
a. Sup: Attic, 'Ret: Main, AH: Main
R ft2
SHGC: SHGC=0.23
6 364
b. U=Factor: Dbl, U=0.33
32.38 ft2
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl', U=0.30
32.38 ft2
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.23
d. U-Factor: other (see details)
38.19 ft2
14. Heating systems
kBtu/hr
Efficiency
SHGC: other (see details)
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average Overhang Depth:
4.251 ft.
Area Weighted Average SHGC:
0.269
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
ft2EF:0.94
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
1820.00 ft2
Credits (Perform method)
Pstat
b. N/A
R=
ft2
ince
c. N/A
R=
ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building .
Construction through the above energy saving features which will be installed (or r exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code comn4+antfeatures. I
Builder Signature: _�Date:
-- I
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating.. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff'.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/15/2021 11:30 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1