HomeMy WebLinkAboutEnergy CodeFILE COPY
4.
FORM R405-2020
FLORIDA-ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 14 Phase 3 Waterstone 2265 ATGGR
Builder Name: ADAMS HOMES
Street: 8344 Amalfi Circle
Permit Office:
City, State, Zip: Fort.Pierce , FL, 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St.. Lucie (Florida Climate Zone 2 )
1: New construction or existing New (From Plans)
10. Wall Type01994.2 sgft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul,.Exterior
R=4.1: :1378.30 ft'
b. Frame - Wood, Exterior
R=13.0 407.83 ft'
3. Number of units, if multiple family 1
c. Frame - Wood, Adjacent
R=13.0 208.00 ft'
4. Number of Bedrooms 4
d. N/A
R= ft'
5: Is this a worst case? �o
11. Ceiling Types (2377.0 sqft.)
In ulation Area
a. Under Attic (Vented)
R=30.0 2277.00 ft'
6. Conditioned floor area above grade (ft') 2277
b. Knee Wall (Vented)
R=19.0 100.00 ft'
Conditioned floor area below grade (ft') 0
c. N/A
R= ft'
7. Windows(273.9 sgft.) Description Area
12. Ducts
R ft'
-a. U-Factor: Dbl, U=0.33 154.00 ft'
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
SHGC: SHGC=0.23
b. U-Factor: DbI, U=0.33 66.00 ft'
13. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a: Central Unit
35.0 SEER:16.00
c. U-Factor: Dbl, U=0.55 ... 35.56 ft'
SHGC: SHGCng,D
Area Weighted Average Overhang.Depth: 5.043 ft.
14. Heating systems
kBtu/hr Efficiency .
Area Weighted Average SHGC: 0.292 -
a. Electric Heat Pump
34.6 HSPF:8.50
8. Skylights Area
c. U-Factor:(AVG) N/A ft'
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons.
9. Floor Types (2277.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2277.00 ft'
b. Conservation features
b. N/A R= ft'
None
c. N/A R= ft'
16. Credits
Pstat
Total Proposed Modified Loads: 65:91
Glass/Floor Area: 0.120PASS
Total Baseline Loads: 67.04
I hereby certify that the plans a tions covered "` :.
Revie f the plans and
this calculation are in compli a ergy
specifications covered by this
�4i'ifiST,�,
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed:
DATE: n4-14-9n91 Winn KPnmany
this building will be ins ected for
p:,,
compliance with Section 553.908;.
I hereby certify that this building, as designed, is in compliance
Florida Statutes
with the Florida Fuel' Cod
�►'pD +�iv
OWNER/
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler. unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance. with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50. (R402.4.1.2).
4/14/2021 10:50 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 5
FO`tM R405-2020 INPUT RUMMARY ICHFCKI IRT RFPnRT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 14 Phase 3 Waterstone 2 Bedrooms: 4
User Conditioned Area: 2277
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Detached
New (From Plans)
Address Type: Lot Information
Lot # 14
Block/Subdivision: Phase.3
PlatBook:
Street: 8344 Amalfi Circle
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Sum Ter Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2277 20493
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2277 20493 Yes 5
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 206.2 ft 0
2277 ft2 ---- 0.35 0 0.65
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 2546 ft2 570 ft2 Medium
N 0.85 N 0.85 No 0 26.57
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 2277 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Under Attic (Vented)
Knee Wall (Vented)
Main 30 Blown
Main 19 Batt
2277 ft2 0.11 Wood
100 ft2 0.11 Wood
4/14/2021 10:50 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 5
I-UkiM K4U5-2UZU
WALLS
Adjacent
Cavity
Width
Height
Sheathing Framing
Solar Belo
Space
w
1
NE
Exterior
Frame - Wood
Main
13
10
2
8
0
81.3 ftz
0
0.23
0.6
0
2
NE
Exterior
Concrete Block - Int Insul
Main
4.1
38
7
10
0
385.8 ftz
0
0
0.6
0
3
SE
Exterior
Frame - Wood
Main
13
4
6
10
0
45.0 ftz
0
0.23
0.6
0
4
SE
Exterior
Concrete Block - Int Insul
Main
4.1
28
6
10
0
285.0 ftz
0
0
0.6
0
5
SW
Exterior
Frame - Wood
Main
13
6
9
8
0
54.0 ftZ
0
0.23
0.6
0
6
SW
Exterior
Concrete Block - Int Insul
Main
4.1
50
3
8
0
402.0 ftz
0
0
0.6
0
7
W
Exterior
Frame - Wood
Main
13
3
10
10
0
38.3 ftz
0
0.23
0.6
0
8
W
Exterior
Concrete Block - Int Insul
Main
4.1
0
5
10
0
4.2 ftZ
0
0
0.6
0
9
NW
Exterior
Frame - Wood
Main
13
18
11
10
0
189.2 ftz
0
0.23
0.6
0
_10
NW
Exterior
Concrete Block - Int Insul
Main
4.1
37
8
8
0
301.3 ftz
0
0
0.6
0
11
-
barage
Frame - Wood
Main
13
26
0
8
10
208.0 ftz
0
0.23
0.01 -
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated
Main
None
.25
3
6 8
20 ftz
2
-
Wood
Main
None
.25
2
8
6 8
17.8 ftz
3
NW
Insulated
Main
None
.25
2
8
6 8
17.8 ftZ
WINDOWS
/
V #
Ornt
Wall
ID
Frame
Panes
NFRC
U-Factor SHGC
Imp
Area
Overhang
Depth Separation
Int Shade
Screening
1
NE
1
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ft'
23 ft 0 in
0 ft 9 in
Drapes/blinds
None
2
NE
2
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ft?
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
SE
3
Vinyl
Low-E Double
Yes
0.33
0.31
N
5.0 ftz
7 ft 8 in
0 ft 6 in
None
None
4
SE
4
Vinyl
Low-E Double
Yes
0.33
0.31
N
13.3 ft2
7 ft 8 in
2 ft 10 in
None
None
5
SE
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
30.0 ftZ
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
6
SE
4
Vinyl
Low-E Double
Yes
0.33
0.21
N
36.0 ft'
1 ft 0 in
2 ft 10 in
Drapes/blinds
Exterior 5
7
SW
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
9.0 ftz
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
8
SW
6
Vinyl
Low-E Double
Yes
0.33
0.23
N
15.0 ftz
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
9
W
7
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ftz
11 ft 0 in
0 ft 4 in
Drapes/blinds
Exterior 5
10
NW
9
Vinyl
Low-E Double
Yes
0.55
0.7
N
17.8 ftz
9 ft 4 in
0 ft 9 in
Drapes/blinds
None
11
NW
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
12.5 ftz
6 ft 8 in
0 ft 4 in
Drapes/blinds
Exterior 5
12
NW
9
Vinyl
Low-E Double
Yes
0.33
0.23
N
30.0 ftz
9 ft 4 in
0 ft 4 in
Drapes/blinds
Exterior 5
13
NW
10
Vinyl
Low-E Double
Yes
0.33
0.23
N
45.0 ftz
1 ft 0 in
0 ft 10 in
Drapes/blinds
Exterior 5
4/14/2021 10:50 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
617ft'
617ft2
64ft 9ft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.0004
2390.9 131.17 246.26 .1324 7
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
Split
Singl HSPF:8.5 34.6 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
Split
Singl SEER: 16 35 kBtu/hr cfm 0.75 1
sys#1
-
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.94 40 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ft2
DUCTS
#
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 456.2 ft
Main
114.05 Default Leakage Main (Default) (Default)
1 1
4/14/2021 10:50 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 5
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan
Heatinf X� Jan
]Feb
f X] Feb
Mar
H Mar
[ ] Apr
[ ] APr
f
Ma
May
Jun
rl Jun
Jul
ri Jul
[X Au
[ AuSeP
ri
Se
[ ]Oct
[ ] Oct
Nov
Nov
H
HDeci
Dec
Ventin [ Jan
[ ] Feb
X Mar
[X] A r
[
Ma
Jun
Jul
[ Aug
Se
[X] Oct
Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ftz
0 ft
0.3
Main
4/14/2021 10:50 AM EnergyGauge®USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 5
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
8344 Amalfi Circle, Fort Pierce, FL, 34951
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1378.30 ftZ
b. Frame - Wood, Exterior
R=13.0
407.83 ftZ
3. Number of units, if multiple family
1
c. Frame - Wood, Adjacent
R=13.0 .
208.00 ftZ
4. Number of Bedrooms
4
d. N/A
R=
ftZ
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
2277.00 ftZ
6. Conditioned floor area (ftZ)
2277
b. Knee Wall (Vented)
R=19.0
100.00 ftZ
7. Windows** Description
Area
c. N/A
R=
Z
ft
a. U-Factor: Desbl, U=tion
154.00Area
ftZ
12. Ducts, location & insulation level
R ftZ
a. Sup: Attic, Ret: Main, AH: Main
6 456.2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33
66.00 ftZ
SHGC: SHGC=0.21
13. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Dbl, U=0.55
35.56 ftZ
a. Central Unit
35.0 SEER:16.00
SHGC: SHGC=0.70
d. U-Factor: other (see details)
18.33 ftZ
SHGC: other (see details)
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
5.043 ft.
a. Electric Heat Pump
34.6
HSPF:8.50
Area Weighted Average SHGC:
0.292
8. Skylights. Description
Area
15. Hot water systems
a. U-Factor(AVG): N/A
Z
ft
a. Electric
Cap: 40 gallons
SHGC(AVG): N/A
EF:0.94
b. Conservation features
9. Floor Types
Insulation
Area
None
a. Slab -On -Grade Edge Insulation
R=0.0
2277.00 ftZ
Credits (Performance method)
Pstat
b. N/A
R=
ftZ
c. N/A
R=
ftZ
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder SignaturDate:
Address of New Home: City/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
4/14/2021 10:51 AM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1