HomeMy WebLinkAboutMicrosoft Word - 20081811 Firestone SBS Recover
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 1 of 68
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Firestone Building Products Company, LLC
200 4th Ave. South
Nashville, TN 37201
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control
Section (in Miami-Dade County) and/or the AHJ (in areas other than Miami-Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Firestone Modified Bitumen Roof Systems over Recover Decks.
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No. 16-0202.05 and consists of pages 1 through 68.
The submitted documentation was reviewed by Jorge L. Acebo.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 2 of 68
ROOFING SYSTEM APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Material: APP/SBS
Deck Type: Recover
Maximum Design Pressure: See Specific Deck assemblies
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Dimensions
Test
Specification
Product
Description
APP 80 Glass Base 39.4" x 65'4" ASTM D6509 Fiberglass reinforced modified bitumen, smooth
surfaced base sheet.
APP Premium Base 39.4" x 65'4" ASTM D6509 Fiberglass reinforced APP modified bitumen,
smooth surfaced base sheet.
SBS Glass Torch Base 39.4" x 33'10" ASTM D6163 Modified bitumen base sheet with a burn-off film
and reinforced with non-woven fiberglass mat.
SBS Glass Torch Base
1.5
39.4" x 65’3" ASTM D6163 Fiberglass reinforced, SBS modified bitumen ply
with sanded top surface and burn off film.
SBS Base 39.4" x 50' ASTM D6163 Fiberglass reinforced SBS base sheet. Applied in
hot asphalt or mechanically attached.
SBS Premium Base 39.6" x 50' ASTM D6163 Fiberglass reinforced SBS base sheet. Applied in
hot asphalt or Multi-Purpose MB Cold Adhesive.
SBS Poly Base 39.6" x 50' ASTM D6164 A smooth surfaced, non-woven polyester
reinforced, modified bitumen base sheet.
SBS Premium Poly
Base
39.4" x 50” ASTM D6164 Polyester reinforced, SBS modified bitumen
membrane with sanded surfaces.
SBS Poly Torch Base 45” x 39” ASTM D6164 Fiberglass reinforced modified bitumen
membrane, SBS rubber modified asphalt
reinforced with a non-woven polyester mat. Ply IV 33” x 180” ASTM D2178 Fiberglass reinforced, asphalt impregnated,
roofing ply. Applied in hot asphalt.
Ply VI 33” x 180” ASTM D2178 Fiberglass reinforced, asphalt impregnated,
roofing ply. Applied in hot asphalt.
MB Base 36" x 108' ASTM D4601 Fiberglass reinforced base sheet, asphalt coated
on both sides. Applied in hot asphalt or
mechanically attached.
SBS Smooth 39.4" x 33'10" ASTM D6164 Smooth surfaced, modified bitumen membrane
reinforced with non-woven polyester mat.
Applied in hot asphalt. APP 160 39" x 32'10" ASTM D6222 Polyester reinforced APP modified bitumen,
smooth surfaced membrane with burn-off film.
APP 160 P 39.4" x 32'9" ASTM D6222 Polyester reinforced modified bitumen, smooth
surfaced membrane. Torch applied for use as a
base or ply sheet only.
APP 160 Cool 39" x 32'10" ASTM D6222 Polyester reinforced APP modified bitumen,
smooth surfaced membrane.
APP 170 39.4" x 32'10" ASTM D6222 Polyester reinforced APP modified bitumen,
smooth surfaced membrane.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 3 of 68
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Dimensions
Test
Specification
Product
Description
APP 170 Cool 39.6" x 33'6" ASTM D6222 Polyester reinforced modified bitumen, smooth
surfaced membrane.
APP 180 39.4" x 32'10" ASTM D6222 Polyester reinforced modified bitumen, granule
surfaced membrane. Torch applied. APP 180-P 39.4" x 32'9" ASTM D6222 Polyester reinforced modified bitumen, granule
surfaced membrane. Torch applied.
APP 180 UltraWhite 39.4" x 32'10" ASTM D6222 Polyester reinforced modified bitumen,
UltraWhite granule surfaced membrane. Torch
applied.
APP 180 FR 39.4" x 32'10" ASTM D6222 Polyester reinforced, fire retardant modified
bitumen, granule surfaced membrane. Torch
applied.
APP 180 FR
UltraWhite
39.4" x 32'10" ASTM D6222 Polyester reinforced, fire retardant modified
bitumen, UltraWhite granule surfaced membrane.
Torch applied.
APP 180 Cool 39.4" x 32'10" ASTM D6222 Polyester reinforced modified bitumen, granule
surfaced membrane.
APP 180 FR Cool 39.4" x 32'10" ASTM D6222 Polyester reinforced, fire retardant modified
bitumen, granule surfaced membrane. Torch
applied.
APP Premium FR 39.4" x 32'10" ASTM D6223 Combination fiberglass scrim and polyester mat
reinforced, fire retardant APP modified bitumen,
granule surfaced membrane.
SBS Glass 39.4" x 33'10" ASTM D6163 Fiberglass reinforced, granule surfaced, modified
bitumen membrane. Applied in hot asphalt.
SBS Glass FR 39.4" x 33'10" ASTM D6163 Fiberglass reinforced, fire rated, granule surfaced,
modified bitumen membrane. Applied in hot
asphalt. SBS Glass FR
UltraWhite
39.4" x 33'10" ASTM D6163 UltraWhite fiberglass reinforced, granule
surfaced, modified bitumen membrane. Applied
in hot asphalt. SBS Torch 48” x 39” ASTM D6164 Granule surfaced, SBS cap reinforced with a non-
woven polyester mat, with burn off film and
fiberglass enhanced.
SBS Torch UltraWhite 48” x 39” ASTM D6164 UltraWhite granule surfaced, SBS cap reinforced
with a non-woven polyester mat, with burn off
film and fiberglass enhanced.
SBS FR Torch 48” x 39” ASTM D6164 Granule surfaced, fire rated, SBS cap reinforced
with a non-woven polyester mat, with burn off
film and fiberglass enhanced.
SBS FR Torch
UltraWhite
48” x 39” ASTM D6164 UltraWhite granule surfaced, fire rated, SBS cap
reinforced with a non-woven polyester mat, with
burn off film and fiberglass enhanced.
SBS Glass FR Torch 39.4" x 33'10" ASTM D6163 Fiberglass reinforced, fire rated, granule surfaced,
modified bitumen membrane. with burn off film
and fiberglass enhanced.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 4 of 68
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Dimensions
Test
Specification
Product
Description
SBS Glass FR Torch
UltraWhite
39.4" x 33'10" ASTM D6163 UltraWhite fiberglass reinforced, fire rated,
granule surfaced, modified bitumen membrane.
with burn off film and fiberglass enhanced.
SBS Cap 39.4" x 33'10" ASTM D6164 Granule surfaced, modified bitumen membrane
reinforced with non-woven polyester mat.
SBS Cap UltraWhite 39.4" x 33'10" ASTM D6164 UltraWhite granule surfaced, modified bitumen
membrane reinforced with non-woven polyester
mat. SBS FR Cap 39.4" x 33'10" ASTM D6164 Granule surfaced, modified bitumen membrane
reinforced with non-woven polyester mat.
SBS FR Cap
UltraWhite
39.4" x 33'10" ASTM D6164 UltraWhite granule surfaced, modified bitumen
membrane reinforced with non-woven polyester
mat.
SBS Premium FR 39.4" x 33'10" ASTM D6164 Granule surfaced, fire rated, modified bitumen
membrane reinforced with non-woven polyester
mat.
SBS Premium FR
UltraWhite
39.4" x 33'10" ASTM D6164 UltraWhite granule surfaced, fire rated, modified
bitumen membrane reinforced with non-woven
polyester mat.
SBS Premium 39.4" x 33'10" ASTM D6164 Granule surfaced, modified bitumen membrane
reinforced with polyester mat. Applied in hot
asphalt.
SBS Premium Torch 39.4" x 33'10" ASTM D6164 Granule surfaced, modified bitumen membrane
with a burn-off film and reinforced with non-
woven polyester mat.
SBS Premium Torch
UltraWhite
39.4” x 33’10” ASTM D6164 UltraWhite granule surfaced, modified bitumen
membrane with a burn-off film and reinforced
with non-woven polyester mat. SBS Premium FR
Torch
39.4" x 33'10" ASTM D6164 Granule surfaced, fire rated, modified bitumen
membrane with a burn-off film and reinforced
with non-woven polyester mat. SBS Premium FR
Torch UltraWhite
39.4” x 33’10” ASTM D6164 UltraWhite granule surfaced, fire rated, modified
bitumen membrane with a burn-off film and
reinforced with non-woven polyester mat.
I.S.O. Twin Pack
Insulation Adhesive
Dual 750 ml
cartridges
Proprietary A two-component polyurethane insulation
adhesive.
I.S.O. Fix II 30 lb. Proprietary A single component polyurethane insulation
adhesive.
I.S.O. Stick 5 gal. Proprietary A two-component polyurethane insulation
adhesive.
Multi-Purpose MB
Cold Adhesive
55 gal. Proprietary An asphalt based adhesive.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 5 of 68
APPROVED INSULATIONS:
TABLE 2
Product Name
Product Description
Manufacturer
(With Current NOA)
ISO 95+ GL (Flat and Tapered) Polyisocyanurate insulation board with glass
reinforced organic facer
Firestone Building Products
Company, LLC
RESISTA (Flat and Tapered) Polyisocyanurate Insulation board with coated
fiberglass facer
Firestone Building Products
Company, LLC
DensDeck Prime Silicon treated gypsum Georgia Pacific Gypsum LLC
SECUROCK Gypsum-Fiber Roof
Board
Gypsum roof board with fiber reinforcement United States Gypsum
Corporation
ISOGARD HD High density Polyisocyanurate roof board with
a coated fiberglass facer
Firestone Building Products
Company, LLC
ISOGARD HD Composite Polyisocyanurate foam core laminated to
ISOGARD HD board
Firestone Building Products
Company, LLC
APPROVED FASTENERS:
TABLE 3
Fastener
Number
Product
Name
Product
Description
Dimensions
Manufacturer
(With Current NOA)
1. Firestone All-Purpose Insulation and membrane
fastener
Various Firestone Building Products
Company, LLC
2. Firestone Heavy-Duty Insulation and membrane
fastener
Various Firestone Building Products
Company, LLC
3. Concrete Drive Fastener 1/4" diameter concrete deck
fastener.
Various Firestone Building Products
Company, LLC
4. MB 2” Barbed Metal
Seam Plate
Metal plates used for membrane
securement.
2" dia Firestone Building Products
Company, LLC
5. Firestone 2-3/8 Barbed
Seam Plate
Membrane seam attachment
plate.
2-3/8" dia Firestone Building Products
Company, LLC
6. 2” Metal Plate Membrane attachment plate. 2" dia Firestone Building Products
Company, LLC
7. Firestone Polymer Glass reinforced nylon fastener
for Gypsum or CWF decks
11/16” dia Firestone Building Products
Company, LLC
8. Firestone Polymer
Fastener Insulation Plate
Galvalume plate for use with the
Polymer Fastener
3” square Firestone Building Products
Company, LLC
9. Insulation Fastening Plate Insulation plate for use with
Firestone Fasteners
3” round Firestone Building Products
Company, LLC
10. Firestone Coiled Metal
Batten Strip
Galvalume AZ55 Batten
Bar
220’ x 1” Firestone Building Products
Company, LLC
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 6 of 68
EVIDENCE SUBMITTED:
Test Agency Test Identifier
Description Date
FM Approvals 3022502 FM 4470 01/29/07
3007328 FM 4470 07/12/02
3030107 FM 4470 05/18/07
3040795 FM 4470 03/24/11
3040109 FM 4470 03/09/11
3041534 FM 4470 03/09/11
3035560 FM 4470 01/11/10
3038191 FM 4470 08/04/11
3040306 FM 4470 09/07/11
3042392 FM 4470 06/08/11
3046870 FM 4470 03/22/13
3047398 FM 4470 08/15/13
3061218 FM 4470 05/10/17
Trinity | ERD F10370.05.08 ASTM C 1289 05/08/08
F10500.10.08-1 ASTM D6163 08/26/08
F31960.05.10-1 ASTM D4977 05/19/10
F31960.05.10-2 ASTM D4977 05/19/10
F31960.08.10-1 ASTM D4977 08/25/10
F31960.08.10-2 ASTM D4977 08/25/10
F35400.05.11 Physical Properties 05/31/11
F41070.08.12 ASTM D6222 08/24/12
U41790.05.12-2-R2 ASTM D6222 02/11/13
U41790.05.12-1-R1 ASTM D6222 01/21/13
PRI Construction Materials FBP-038-02-03 ASTM D6164 01/12/11
Technologies LLC FBP-038-02-04 ASTM D6164 01/12/11
FBP-038-02-02 ASTM D6164 01/12/11
FBP-038-02-01 ASTM D6164 12/27/10
FBP-043-02-03 ASTM D6164 07/26/11
FBP-043-02-02 ASTM D6164 08/02/11
FBP-043-02-04 ASTM D6164 07/26/11
FBP-043-02-01 ASTM D6164 08/02/11
FBP-042-02-01 ASTM D6164 07/26/11
FBP-042-02-02 ASTM D6164 07/27/11
FBP-058-02-01 ASTM D4601 12/12/08
FBP-057-02-01 ASTM D2178 12/12/08
FBP-056-02-01 ASTM D2178 12/12/08
FBP-087-02-01 ASTM D4798 03/22/13
FBP-088-02-01 ASTM D4798 03/22/13
FBP-109-02-01 TAS 114(J) 04/19/13
FBP-113-02-01 TAS 114(J) 04/17/13
FBP-118-02-01 Rev.1 TAS 114(J) 01/02/14
FBP-123-02-01 TAS 114(J) 07/26/13
FBP-124-02-01 TAS 114(J) 08/02/13
FBP-126-02-01 ASTM D 6163 12/03/13
FBP-127-02-01 ASTM D 6164 11/20/13
FBP-133-02-01 Rev.3 TAS 114(J) 02/10/14
FBP-133-02-02 Rev.1 TAS 114(J) 01/02/14
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 7 of 68
EVIDENCE SUBMITTED:
Test Agency Test Identifier
Description Date
PRI Construction Materials FBP-141-02-01 TAS 114(J) 12/18/13
Technologies LLC FBP-142-02-01.1 TAS 114(J) 01/02/14
FBP-142-02-02 Rev.1 TAS 114(J) 10/01/13
FBP-059-02-01.6 Various 03/15/18
FBP-168-02-03 ASTM D 6164 07/14/14
FBP-184-02-03 TAS 114(J) 07/31/14
FBP-181-02-01B.1 TAS 114(J) 07/24/14
FBP-196-02-03 TAS 114 (J) 10/10/14
FBP-193-02-01 TAS 114(J) 10/10/14
DECK STRESS ANALYSIS CALCULATIONS/REPORTS
Engineer/Agency Identifier Assemblies: Date
Zachary Priest, P.E. Letter B(3), B(4), B(5), C(24), C(9),
C(10), C(11), C(12), C(20), C(21),
C(14), C(15), C(13), C(22), C(23),
C(16), C(17), C(18), C(19), D(3),
D(4)
02/08/16
FM Approval Deck Limitation C(7) 01/01/13
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 8 of 68
APPROVED ASSEMBLIES
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete
System Type B(1): Base layers of insulation mechanically fastened, top layer adhered with approved asphalt.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 2” thick 2 or 3 with 9 1:2 ft2
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ¼” thick N/A N/A
Note: Top layer of insulation shall be adhered with I.S.O. Twin Pack Insulation Adhesive applied in ½” to ¾”
wide ribbons spaced 12” o.c. or I.S.O. FIX II or I.S.O. Stick applied in ¾” to 1” wide ribbons spaced 12” o.c.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One or more plies of SBS Smooth (over DensDeck only), SBS Base, SBS Premium Base,
SBS Poly Base, SBS Premium Poly Base (over DensDeck only, with hot asphalt only), or
MB Base (over DensDeck only, with hot asphalt only) fully adhered with Firestone Multi-
Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the
EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, or (Over DensDeck only)
SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(over DesnDeck only) One or more plies of APP 160, APP 160 P, APP 170, fully torch
adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 9 of 68
Membrane: (only over SBS Base, SBS Poly Base, SBS Smooth, or Premium Base) One ply of SBS
Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS Premium, SBS
Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or SBS Glass FR
UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of
1.5-2.0 gal./sq. or hot asphalt (over MB Base, SBS Base, SBS Poly Base, SBS Premium
Base, SBS Premium Poly Base, or SBS Smooth) applied in the EVT range at a rate of 20-25
lbs./sq. with minimum 3” wide side laps.
Or
(over SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Premium Poly Base, or SBS
Poly Torch Base only) One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite,
SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite,
SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch
UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Only over SBS Base, SBS Poly Base, SBS Premium Base) One ply of Firestone APP 170
Cool, APP 180 Cool or APP 180 FR Cool, fully adhered to the base sheet with Firestone
Multi-Purpose MB Cold Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps
Or
(over APP 160, APP 160 P, or APP 170 only) One ply of Firestone APP 160, APP 160 P,
APP 170, APP Premium FR, APP 180, APP 180 UltraWhite, APP 180 FR, APP 180 FR
UltraWhite torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 160, APP 160 P, APP 170, APP 170 Cool, SBS Smooth, APP 180-P,
APP 180 FR Cool, or APP 180 Cool.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Roof gravel in a flood coat of approved asphalt..
2. Roof gravel in Multi-Purpose MB Cold Adhesive (SBS roof covers)
Maximum Design
Pressure:
-45 psf. (See General Limitation #9)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 10 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete
System Type B(2): Base layers of insulation mechanically fastened, top layer adhered with approved asphalt.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ½” thick 2 or 3 with 9 1:2 ft2
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Middle Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1.5” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ¼” thick N/A N/A
Note: Top layer of insulation shall be adhered with I.S.O. Twin Pack Insulation Adhesive applied in ½” to ¾”
wide ribbons spaced 12” o.c. or with I.S.O. Stick applied in ¾” to 1" ribbons spaced 12" o.c. Please refer to
Roofing Application Standard RAS 117 for insulation attachment
System 1:
Base Sheet:
One ply of Firestone SBS Base, SBS Premium Base or SBS Smooth (not over SECUROCK),
fully adhered in full mopping of approved asphalt within the EVT range and at a rate of 20-25
lbs./sq. with minimum 3” wide side laps.
Ply Sheet (Optional): One or more plies of Firestone Ply IV, , Ply VI ply, sheet adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-25 lbs./sq. with minimum 3”
wide side laps.
Membrane: One ply of Firestone SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap
UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS
Glass FR, SBS Glass FR UltraWhite adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
(only over SBS Base, SBS Poly Base, SBS Smooth, or Premium Base) One ply of Firestone
SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Glass, SBS Glass FR, SBS Glass FR UltraWhite, SBS Premium, SBS Premium FR or SBS
Premium FR UltraWhite cap sheet fully adhered to the base sheet with Multi-Purpose MB
Cold Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 11 of 68
System 2: Base Sheet: One ply of Firestone SBS Poly Torch Base, SBS Glass Torch Base sheet, or
(Over DensDeck only) SBS Glass Torch Base 1.5 torch applied with minimum 3” wide side
laps.
Membrane: One ply of Firestone SBS Torch, SBS Torch UltraWhite, SBS FR Torch, SBS FR Torch
UltraWhite, SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Premium Torch,
SBS Premium Torch UltraWhite, SBS Premium FR Torch or SBS Premium FR Torch
UltraWhite cap sheet torch adhered to the base sheet with the 3” sidelaps heat fused with a
torch.
Surfacing (Optional): *Required over SBS Smooth, APP 160, APP 160 P, APP 170, APP 180-P, APP 180 FR
Cool, or APP 180 Cool.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-45 psf. (See General Limitation #9)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 12 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 gauge, Grade 33 steel deck secured to structural supports spaced maximum 6 ft.
o.c. or concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-1/4”
HWH screws. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Characteristic Resistance Force (MCRF) of 168 lbf. when tested with Firestone
All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type B(3): Base layer of insulation mechanically fastened, top layer of insulation adhered with approved
adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1.5” thick 1 (steel) with 9
2 or 3 (concrete) with 9
1:1.6 ft2
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ½” thick N/A N/A
Note: Top layer of insulation shall be adhered with I.S.O. Twin Pack Insulation Adhesive applied in ½” to ¾”
wide ribbons spaced 6” o.c. (not with SECUROCK) or with I.S.O. Fix II or I.S.O. Stick applied in ¾” to 1” wide
ribbons spaced 6” o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only), or MB Base fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or
hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side
laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, or SBS Glass Torch Base
1.5 torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 13 of 68
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or
SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-25
lbs./sq. with minimum 3” wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5 gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 14 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 gauge, Grade 33 steel deck secured to structural supports spaced maximum 6 ft.
o.c. or concrete deck. Steel deck is fastened to supports at every flute with 5/8” puddle welds.
Laps stitched 24” o.c. with #1/4x7/8” HWH self-drilling screws. *The deck should record a
Minimum Characteristic Resistance Force (MCRF) of 240 lbf. when tested with Firestone
All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type B(4): Base layer of insulation mechanically fastened, top layer of insulation adhered with approved
adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL
Minimum 2” thick 1 (steel) with 9
2 or 3 (concrete) with 9
1:1.6 ft2
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Middle Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum ½” thick N/A N/A
Note: Middle and Top insulation layers shall be adhered with I.S.O. Stick applied in ¾” to 1” wide ribbons
spaced 6” o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite
insulation boards used as a top layer shall be installed with the polyisocyanurate face down.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only), or MB Base fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or
hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side
laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, or SBS Glass Torch Base
1.5 torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 15 of 68
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or
SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-25
lbs./sq. with minimum 3” wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-67.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 16 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural supports at a maximum spacing of
6 ft. o.c. or concrete deck. deck. Steel deck is fastened to supports at every flute with 5/8”
puddle welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Characteristic Resistance Force (MCRF) of 160 lbf. When tested with Firestone
All Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type B(5): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1.5” thick 1 (steel) with 9
2 or 3 (concrete) with 9
1:1.78 ft2
Note: Base layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISOGARD HD
Minimum ½” thick NA NA
Note: Top layer of insulation shall be adhered with I.S.O. Twin Pack Insulation Adhesive applied in ½” to ¾”
wide ribbons spaced 12” o.c. or I.S.O. FIX II or I.S.O. Stick applied in ¾” to 1” wide ribbons spaced 12” o.c.
Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Base Sheet: One or more plies of APP 160 Cool, APP 170 Cool, MB Base, SBS Base, SBS Premium
Base, SBS Poly Base, SBS Premium Poly Base, or SBS Smooth fully adhered with Firestone
Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide
side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 17 of 68
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, SBS Premium
Base, SBS Poly Base, SBS Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot
asphalt only), or MB Base fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40
lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly Torch
Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
Membrane:
(Not for use with SBS) One ply of APP 180 FR Cool, APP 180 Cool or APP Premium FR
fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0
gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS) One ply of APP 180, APP 180 UltraWhite, APP 180 FR, APP 180
FR UltraWhite, APP 180 Cool, APP 180 FR Cool, or APP Premium FR torch adhered with
minimum 3” wide side laps.
Or
(Not for use with APP) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR
Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS
Glass, SBS Glass FR, SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose
MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.., or hot asphalt applied in the EVT
range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP) One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite,
SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite,
SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR
Torch UltraWhite torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-45 psf. (See General Limitation #7)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 18 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete
System Type C(1): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1.5” thick 2, 3 with 9 1:2 ft2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of
fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.
with minimum 3” wide side laps.
Ply Sheet (Optional): One or more plies of SBS Smooth (hot asphalt only), SBS Base, SBS Premium Base, SBS
Poly Base, SBS Premium Poly Base (hot asphalt only), Ply IV (hot asphalt only), Ply VI (hot
asphalt only), or MB Base (hot asphalt only) fully adhered with Firestone Multi-Purpose MB
Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a
rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or
SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive
(only over SBS Base, SBS Poly Base, SBS Smooth, or Premium Base) applied at a rate of
1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-25 lbs./sq. with
minimum 3” wide side laps.Or
(Only over SBS Base, SBS Poly Base, SBS Premium Base) One ply of Firestone APP 170
Cool, APP 180 Cool or APP 180 FR Cool fully adhered to the base sheet with Firestone
Multi-Purpose MB Cold Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
Surfacing (Optional): *Required over SBS Smooth, APP 160, APP 160 P, APP 170, APP 180-P, APP 180 FR
Cool, or APP 180 Cool.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Gravel or slag at 400 lb. and 300 lb., respectively, set in a flood coat of type III or IV
asphalt at 60 lb./sq.
2. Karnak No. 97, No. 97 AF or No. 169 at an application rate of 1.5-3 gal./sq.
Maximum Design
Pressure:
-45 psf. (See General Limitation #9)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 19 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete
System Type C(2): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Maximum 1.0” thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISOGARD HD
Minimum ½” thick 1 or 2 with 9 1:2.7 ft2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of
fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.
with minimum 3” wide side laps.
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base (hot asphalt only), Ply IV (hot asphalt only), Ply VI (hot asphalt only), or
MB Base (hot asphalt only) fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40
lbs./sq. with minimum 3” wide side laps.
Or
(over SBS Premium Poly Base only) One or more plies of SBS Glass Torch Base, SBS Poly
Base Torch, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 20 of 68
Membrane: (Not for use with APP sheets) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS
FR Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS
Glass, SBS Glass FR, or SBS Glass FR UltraWhite fully adhered with Firestone Multi-
Purpose MB Cold Adhesive (Only over SBS Smooth, SBS Base, SBS Poly Base, or SBS
Premium Base) applied at a rate of 1.5-2.0 gal./sq. or hot asphalt (over MB Base, SBS Base,
SBS Poly Base, SBS Premium Base, SBS Premium Poly Base, Ply IV, Ply VI, or SBS
Smooth) applied in the EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(over SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Premium Poly Base, or SBS
Poly Torch Base only) One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite,
SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite,
SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch
UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Only over SBS Base, SBS Poly Base, SBS Premium Base)One ply of Firestone APP 170
Cool, APP 180 Cool or APP 180 FR Cool fully adhered to the base sheet with Firestone
Multi-Purpose MB Cold Adhesive applied at 1½ - 2 gal./sq. with minimum 3” wide side laps.
Surfacing (Optional): Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Roof gravel in Multi-Purpose MB Cold Adhesive..
2. Roof gravel in a flood coat of approved asphalt..
Maximum Design
Pressure:
-45 psf. (See General Limitation #9)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 21 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete, Steel
System Type C(3): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) (over Concrete Deck only) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1.5” thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased
maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck Prime
Minimum ¼” thick 1 or 2 with 9 (steel deck)
2 or 3 with 9 (concrete) 1:4 ft2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of
fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base (hot asphalt only), Ply IV (hot asphalt only), Ply VI (hot asphalt only) or
MB Base (hot asphalt only) fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
One or more plies of SBS Glass Torch Base, or SBS Poly Torch Base, or SBS Glass Torch
Base 1.5torch adhered with minimum 3” wide side laps.
Or
One or more plies of APP 160, APP 160 P, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 22 of 68
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or
SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive
(Only over SBS Base, SBS Poly Base, SBS Smooth, or SBS Premium Base) applied at a
rate of 1.5-2.0 gal./sq. or hot asphalt (over MB Base, SBS Base, SBS Poly Base, SBS
Premium Base, SBS Premium Poly Base, Ply IV, Ply VI, or SBS Smooth) applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(over SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Premium Poly Base, or SBS
Poly Torch Base only) One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite,
SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite,
SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch
UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Only over SBS Base, SBS Poly Base, SBS Premium Base) One ply of Firestone APP 170
Cool, APP 180 Cool or APP 180 FR Cool fully adhered to the base sheet with Firestone
Multi-Purpose MB Cold Adhesive applied at 1½ - 2 gal./sq. with minimum 3” wide side laps.
Or
(Only over APP 160, APP 160 P, APP 170) One ply of Firestone APP 160, APP 160 P, APP
170, or APP Premium FR, APP 180, APP 180 UltraWhite, APP 180 FR, APP 180 FR
UltraWhite or torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over SBS Smooth, APP 160, APP 160 P, APP 170, APP 180-P, APP 180 FR
Cool, or APP 180 Cool.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Roof gravel at 400 lb./sq. in a flood coat of approved asphalt
2. Roof gravel in Multi-Purpose MB Cold Adhesive at 2.5 gal./sq.
Maximum Design
Pressure:
-45 psf. (See General Limitation #9)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 23 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete, Steel
System Type C(4): Insulation mechanically fastened, membranes adhered with approved adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck Prime
Minimum ¼” thick 1 or 2 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:2.7 ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum ½” thick 1 or 2 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:2.7 ft2
ISOGARD HD
Minimum ½” thick 1 or 2 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:2.7 ft2
Note: Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more plies of SBS Smooth (not over SECUROCK), SBS Base, SBS Premium Base,
SBS Poly Base (not over SECUROCK), SBS Premium Poly Base (hot asphalt only, not
over SECUROCK), or MB Base (hot asphalt only, not over SECUROCK) fully adhered
with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or (not
for ISOGARD HD) hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with
minimum 3” wide side laps.
Or
(Not for ISOGARD HD) One or more plies of SBS Glass Torch Base, SBS Poly Torch Base,
or (only over DensDeck Prime) SBS Glass Torch Base 1.5 torch adhered with minimum 3”
wide side laps.
Or
(Only over DensDeck Prime) One or more plies of APP 160, APP 160 P, APP 170, fully
torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 24 of 68
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or
SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive
(Only over SBS Smooth, SBS Base, SBS Poly Base, or SBS Premium Base) applied at a
rate of 1.5-2.0 gal./sq. or hot asphalt (over MB Base, SBS Base, SBS Poly Base, SBS
Premium Base, SBS Premium Poly Base, Ply IV, Ply VI, or SBS Smooth) applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(over SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Premium Poly Base, or SBS
Poly Torch Base only) One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite,
SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite,
SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch
UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Only over SBS Base, SBS Poly Base, SBS Premium Base) One ply of Firestone APP 170
Cool, APP 180 Cool or APP 180 FR Cool fully adhered to the base sheet with Firestone
Multi-Purpose MB Cold Adhesive applied at 1½ - 2 gal./sq. with minimum 3” wide side laps.
Or
(Only over APP 160, APP 160 P, APP 170) One ply of Firestone APP 160, APP 160 P, APP
170, APP Premium FR, APP 180, APP 180 UltraWhite, APP 180 FR, APP 180 FR
UltraWhite torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over SBS Smooth, APP 160, APP 160 P, APP 170, APP 180-P, APP 180 FR
Cool, or APP 180 Cool.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Roof gravel at 400 lb./sq. in a flood coat of approved asphalt.
Maximum Design
Pressure:
-45 psf. (See General Limitation #9)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 25 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete
System Type C(5): Insulation mechanically fastened, membranes adhered with approved adhesive.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 2” thick 2 or 3 with 9 1:1.33 ft2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of
fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.
with minimum 3” wide side laps.
Or
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or
SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-25
lbs./sq. with minimum 3” wide side laps.Or
(Only over SBS Base, SBS Poly Base, or SBS Permium Base) One ply of SBS Torch, SBS
Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch,
SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite
torch adhered with minimum 3” wide side laps.
Or
(only over SBS Base, SBS Poly Base, or SBS Premium Base) One ply of Firestone APP 170
Cool, APP 180 Cool or APP 180 FR Cool fully adhered to the base sheet with Firestone
Multi-Purpose MB Cold Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
Or
(only over SBS Base, SBS Poly Base, or SBS Premium Base) One ply of Firestone APP
160, APP 160 P, APP 170, APP 180, APP 180 UltraWhite, APP 180 FR, APP 180 FR
UltraWhite torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over SBS Smooth, APP 160, APP 160 P, APP 170, APP 180-P, APP 180 FR
Cool, or APP 180 Cool.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Gravel or slag at 400 lb. and 300 lb., respectively, set in a flood coat of type III or IV
asphalt at 60 lb./sq.
2. Karnak No. 97, No. 97 AF or No. 169 at an application rate of 1.5-3 gal./sq.
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 26 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete
System Type C(6): All layers of insulation simultaneously attached.
Vapor Barrier Optional) One 4-6 mil thick polyethylene vapor retarder placed over steel deck with min. 2”
wide laps sealed with duct tape.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, Tapered ISO 95+ GL
Minimum 2.2” thick to Maximum 12” thick N/A N/A
RESISTA, Tapered RESISTA
Minimum 2.2” thick to Maximum 12” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeckPrime, SECUROCK Gypsum-Fiber Roof Board
Minimum 1/2” thick 2 or 3 with 9 1:1.33 ft2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of
fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Base Sheet: One ply of Firestone MB Base (not over SECUROCK), SBS Base, SBS Poly Base (not over
SECUROCK), SBS Premium Base (not over SECUROCK) or SBS Smooth (not over
SECUROCK) fully adhered to the insulation in full mopping of approved asphalt within the
EVT range and at a rate of 20-25 lbs./sq.
Ply Sheet: (Optional) One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly
Base, SBS Premium Poly Base, Ply IV, Ply VI, or MB Base fully adhered hot asphalt applied
in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or
SBS Glass FR UltraWhite fully adhered with or hot asphalt applied in the EVT range at a rate
of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(over SBS Premium Poly Base only) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Maximum Design
Pressure:
-97.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 27 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 gauge, Grade 80 steel deck secured to structural supports spaced maximum 6 ft.
o.c., Steel deck secured with Tek 4, TRAXX/4 or TRAXX/5 fasteners spaced 6” o.c. (One
fastener per bearing attachment point). Deck side laps are secured a maximum 12” o.c. with
Tek 1 or TRAXX/1 fasteners.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(7): All layers of insulation simultaneously attached.
Vapor Barrier
(Optional):
One 4-6 mil thick polyethylene vapor retarder placed over steel deck with min. 2” wide laps
sealed with duct tape.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeckPrime, SECUROCK Gypsum-Fiber Roof Board
Minimum ½” thick 1 or 2 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.33 ft2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of
fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Base Sheet: One ply of Firestone MB Base (not over SECUROCK), SBS Base, SBS Poly Base (not over
SECUROCK), SBS Premium Base or SBS Smooth (not over SECUROCK) fully adhered to
the insulation in full mopping of approved asphalt within the EVT range and at a rate of 20-25
lbs./sq.
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV, Ply VI,, or MB Base fully adhered or hot asphalt applied in the
EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Membrane: (over MB Base, SBS Base, SBS Poly Base, SBS Premium Base, SBS Premium Poly Base,
Ply IV, Ply VI, or SBS Smooth) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap,
SBS FR Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite,
SBS Glass, SBS Glass FR, or SBS Glass FR UltraWhite fully adhered or hot asphalt applied
in the EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(over SBS Premium Poly Base only) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Maximum Design
Pressure:
-97.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 28 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete
System Type C(8): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1.5” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum ½” thick 2 or 3 with 9 1:1.45 ft2
Note: Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of
fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard
RAS 117 for insulation attachment.
Base Sheet: One or more plies of SBS Base, SBS Premium Base, SBS Poly Base (Cold Adhesive only),
fully adhered to the insulation with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with
minimum 3” wide side laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, torch adhered with
minimum 3” wide side laps.
Ply Sheet (Optional): (over SBS Base, SBS Poly Base, or SBS Premium Base only) One or more plies of SBS
Smooth (hot asphalt only), SBS Base, SBS Premium Base, SBS Poly Base, SBS Premium
Poly Base (hot asphalt only), Ply IV (hot asphalt only), Ply VI (hot asphalt only), fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.
or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side
laps.
Or
(over SBS Glass Torch Base, or SBS Poly Torch Base only) One or more plies of SBS
Glass Torch Base, SBS Poly Torch Base, or SBS Glass Torch Base 1.5 torch adhered with
minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 29 of 68
Membrane: One ply of SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap
UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass,
SBS Glass FR, SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB
Cold Adhesive (only over SBS Base, SBS Poly Base, SBS Smooth, or Premium Base)
applied at a rate of 1.5-2.0 gal./sq. or hot asphalt (over SBS Base, SBS Poly Base, SBS
Premium Base, SBS Premium Poly Base, Ply IV, Ply VI, or SBS Smooth) applied in the
EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
(over SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Premium Poly Base, or
SBS Poly Torch Base only) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 160 Cool, APP 170 Cool, APP 180-P, APP 180 Cool, APP 180 FR
Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-90 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 30 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck is secured to structural support at a maximum spacing
of 6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with 5/8”
puddle welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Characteristic Resistance Force (MCRF) of 214 lbf. when tested with Firestone
All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(9): All layers of insulation simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 2” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.78 ft2
ISOGARD HD Composite
Minimum 1.5” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.78 ft2
DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ½” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.78 ft2
Note: All Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only) MB Base, fully
adhered to the insulation with Firestone Multi-Purpose MB Cold Adhesive applied at a rate
of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. (onlt
DensDeck and SECUROCK) with minimum 3 in. wide side laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Base Torch, SBS Glass Torch Base
1.5 torch adhered (only DensDeck and SECUROCK) with minimum 3 in. wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 31 of 68
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base, SBS Premium Poly Base, SBS Poly Base, SBS
Premium Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only), MB Base, fully adhered
with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot
asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3 in. wide side
laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Base Torch, SBS Glass Torch Base
1.5 torch adhered with minimum 3 in. wide side laps.
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, SBS
Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied
at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq.
with minimum 3 in. wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3 in. wide side laps.
Maximum Design
Pressure:
-60 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 32 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural support at a maximum spacing of
6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-1/4”
HWH screws. Laps stitched 24” o.c. with #1/4 x 7/8” HWH screws. *The deck should record
a Minimum Characteristic Resistance Force (MCRF) of 216 lbf. when tested with Firestone
All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(10): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
RESISTA
Minimum 1” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.6 ft2
ISOGARD HD Composite
Minimum 1.5” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.6 ft2
Note: Top Layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, MB Base, fully adhered to the insulation with Firestone Multi-Purpose
MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base SBS Premium Poly Base, SBS Poly Base, SBS
Premium Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only), or MB Base, fully adhered
with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot
asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, SBS Glass Torch Base 1.5
torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 33 of 68
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, SBS
Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied
at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq.
with minimum 3” wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3” wide side laps.
Maximum Design
Pressure:
-67.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 34 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural support at a maximum spacing of
6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-1/4”
HWH screws. Laps stitched 24” o.c. with #1/4 x 7/8” HWH screws. *The deck should record
a Minimum Characteristic Resistance Force (MCRF) of 180 lbf. When tested with Firestone
All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(11): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck Prime
Minimum ½” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.33 ft2
Note: Top Layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base fully adhered to the insulation with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base, SBS Premium Poly Base, SBS Poly Base, SBS
Premium Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only), or MB Base, fully adhered
with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot
asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, SBS Glass Torch Base 1.5
torch adhered with minimum 3” wide side laps.
Membrane: One ply of SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap
UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS
Glass FR, SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate
of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3” wide side laps.
Maximum Design
Pressure:
-67.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 35 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural support at a maximum spacing
of 6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-
1/4” HWH screws. Laps stitched 24” o.c. with #1/4 x 7/8” HWH screws. *The deck should
record a Minimum Characteristic Resistance Force (MCRF) of 267 lbf. when tested with
Firestone All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(12): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+GL, RESISTA
Minimum 1” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum ½” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.78 ft2
Note: Top Layer shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more plies of SBS Smooth, SBS Base, , SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV (hot asphalt only), Ply VI, or MB Base, fully adhered to the
insulation with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0
gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3”
wide side laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, SBS Glass Torch Base
1.5 torch adhered with minimum 3” wide side laps.
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base, , SBS Premium Poly Base, SBS Poly Base,
SBS Premium Base, Ply IV (hot asphalt only), Ply VI, or MB Base, fully adhered with
Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt
applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, SBS Glass Torch Base
1.5 torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 36 of 68
Membrane: One ply of SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap
UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass,
SBS Glass FR, SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB
Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at
a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-75 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 37 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural support at a maximum spacing
of 6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-
1/4” HWH screws. Laps stitched 24” o.c. with #1/4 x 7/8” HWH screws. *The deck should
record a Minimum Characteristic Resistance Force (MCRF) of 267 lbf. when tested with
Firestone All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(13): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISOGARD HD Composite
Minimum 1.5” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.78 ft2
Note: Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more plies of SBS Smooth, SBS Base, , SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, MB Base, fully adhered to the insulation with Firestone Multi-Purpose
MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base, SBS Premium Poly Base, SBS Poly Base, SBS
Premium Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only), or MB Base, fully adhered
with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot
asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, SBS Glass Torch Base 1.5
torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 38 of 68
Membrane: One ply of SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap
UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS
Glass FR, SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate
of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3” wide side laps.
Maximum Design
Pressure:
-75 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 39 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck is secured to structural support at a maximum spacing
of 6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-
1/4” HWH screws. Laps stitched 24” o.c. with #1/4 x 7/8” HWH screws. *The deck should
record a Minimum Characteristic Resistance Force (MCRF) of 320 lbf. when tested with
Firestone All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(14): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISOGARD HD Composite
Minimum 1.5” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:2.67 ft2
Note: Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, MB Base, fully adhered to the insulation with Firestone Multi-Purpose
MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3 in. wide side laps.
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base, SBS Premium Poly Base, SBS Poly Base, SBS
Premium Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only, MB Base, fully adhered
with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot
asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3 in. wide side
laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, SBS Glass Torch Base
1.5 torch adhered with minimum 3 in. wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 40 of 68
Membrane: One ply of SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap
UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass,
SBS Glass FR, SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB
Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or LiquiGard Membrane Adhesive applied
at a rate of 1.5-2.0 gal./sq., or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq.
with minimum 3 in. wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3 in. wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-60 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 41 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck is secured to structural support at a maximum spacing
of 6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-
1/4” HWH screws. Laps stitched 24” o.c. with #1/4 x 7/8” HWH screws. *The deck should
record a Minimum Characteristic Resistance Force (MCRF) of 140 lbf. when tested with
Firestone All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(15): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISOGARD HD
Minimum ½” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete)
1:1.33 ft2
Note: All Insulation shall be mechanically attached with fasteners and density described above. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board
shall be increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for
fastening details.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, MB Base, Ply IV (hot asphalt only), or Ply VI (hot asphalt only fully
adhered to the insulation with Firestone Multi-Purpose MB Cold Adhesive applied at a rate
of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Ply Sheet: (Optional) One or more plies of SBS Smooth, SBS Base, SBS Premium Poly Base, SBS Poly
Base, SBS Premium Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only, MB Base, fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.
or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3 in. wide
side laps.
Or
(Optional) One or more plies of SBS Glass Torch Base, SBS Poly Base Torch, SBS Glass
Torch Base 1.5 torch adhered with minimum 3 in. wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 42 of 68
Membrane:
One ply of SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap
UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass,
SBS Glass FR, SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB
Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at
a rate of 20-40 lbs./sq. with minimum 3 in. wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3 in. wide side laps.
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 43 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural supports at amaximum spacing
of 6 ft. o.c. or concrete deck. Steel deck is fastened to supports at every flute with 5/8”
puddle welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Charcteristic Resistance Force (MCRF) of 280 lbf. When tested with Firestone
All Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(16): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISOGARD HD Composite
Minimum 2” thick
1 with 9 (steel)
2 or 3 with 9 (concrete)
1:2.67 ft2
Note: All Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet:
One or more layers of APP 160 Cool, or APP 170 Cool fully adhered with Firestone Multi-
Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side
laps.
Or
One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, or MB Base fully adhered with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, SBS Premium
Base, SBS Poly Base, SBS Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot
asphalt only), or MB Base fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40
lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly Torch
Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 44 of 68
Membrane:
(Not for use with APP sheets) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap,
SBS FR Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite,
SBS Glass, SBS Glass FR, or SBS Glass FR UltraWhite fully adhered with Firestone Multi-
Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180 Cool or
APP 180 FR Cool fully adhered to the base sheet with Firestone Multi-Purpose MB Cold
Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180, APP 180
UltraWhite, APP 180 Cool, APP 180 FR, APP 180 FR UltraWhite or APP 180 FR Cool
torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 45 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 40 steel deck secured to structural supports at a maximum spacing
of 6 ft. o.c. or concrete deck. Steel deck is fastened to supports at every flute with 5/8”
puddle welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Charcteristic Resistance Force (MCRF) of 320 lbf. When tested with Firestone
All Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(17): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick NA NA
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board, DensDeck Prime
Minimum ½” thick 1 with 9 (steel)
2 or 3 with 9 (concrete)
1:1.78 ft2
ISOGARD HD Composite
Minimum 1.5” thick 1 with 9 (steel)
2 or 3 with 9 (concrete)
1:1.78 ft2
ISO 95+ GL
Minimum 2” thick 1 with 9 (steel)
2 or 3 with 9 (concrete)
1:1.78 ft2
Note: All Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more layers of APP Premium Base (over ISO 95+ GL only), APP 160 Cool, or
APP 170 Cool fully adhered to the insulation with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Only when SECUROCK Gypsum-Fiber Roof Board or DensDeck Prime is used) One
or more layers of APP 80 Glass Base, APP Premium Base, APP 160, APP 160 P, APP 160
Cool, APP 170, or APP 170 Cool fully adhered by torch adhering with minimum 3” wide
side laps.
Or
One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, or MB Base fully adhered with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Only when SECUROCK Gypsum-Fiber Roof Board or DensDeck Prime is used) One
or more plies of SBS Glass Torch Base, SBS Poly Torch Base, or SBS Glass Torch Base 1.5
torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 46 of 68
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, SBS
Premium Base, SBS Poly Base, SBS Premium Poly Base, Ply IV, Ply VI, or MB Base fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0
gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3”
wide side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly
Torch Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
Membrane:
(Not for use with APP sheets) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap,
SBS FR Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite,
SBS Glass, SBS Glass FR, or SBS Glass FR UltraWhite fully adhered with Firestone Multi-
Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180 Cool or
APP 180 FR Cool fully adhered to the base sheet with Firestone Multi-Purpose MB Cold
Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180, APP 180
UltraWhite, APP 180 Cool, APP 180 FR, APP 180 FR UltraWhite or APP 180 FR Cool
torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-90 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 47 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural support at a maximum spacing of
6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with 5/8” puddle
welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record a
Minimum Characteristic Resistance Force (MCRF) of 264 lbf. when tested with Firestone
All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(18): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck Prime, SECUROCK Gyspsum-Fiber Roof Board
Minimum ½” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete) 1:1.6 ft2
ISOGARD HD Composite
Minimum 1.5” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete) 1:1.6 ft2
Note: All Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more layers of APP 160 Cool, or APP 170 Cool fully adhered to the insulation with
Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. with
minimum 3” wide side laps.
Or
(Not for ISOGARD HD Composite) One or more layers of APP 80 Glass Base, APP
Premium Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully
adhered by torch adhering with minimum 3” wide side laps.
Or
One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only), or MB Base fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.
or hot asphalt (Not for ISOGARD HD Composite) applied in the EVT range at a rate of 20-
40 lbs./sq. with minimum 3” wide side laps.
Or
(Not for ISOGARD HD Composite) One or more plies of SBS Glass Torch Base, SBS Poly
Torch Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 48 of 68
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, SBS Premium
Base, SBS Poly Base, SBS Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot
asphalt only), or MB Base fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40
lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly Torch
Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
Membrane:
(Not for use with SBS) One ply of APP 180 FR Cool, APP 180 Cool or APP Premium FR
fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0
gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS) One ply of APP 180, APP 180 UltraWhite, APP 180 FR, APP 180
FR UltraWhite, APP 180 Cool, APP 180 FR Cool, or APP Premium FR torch adhered with
minimum 3” wide side laps.
Or
(Not for use with APP) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR
Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS
Glass, SBS Glass FR, SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose
MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT
range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP) One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite,
SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite,
SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR
Torch UltraWhite torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-82.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 49 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck is secured to structural supports at a maximum
spacing of 6 ft. o.c. or concrete deck. Steel deck is fastened to supports at every flute with
5/8” puddle welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should
record a Minimum Charcteristic Resistance Force (MCRF) of 240 lbf. When tested with
Firestone All Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(19): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1/2” thick NA NA
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board, DensDeck Prime
Minimum ½” thick 1 with 9 (steel)
2 or 3 with 9 (concrete)
1:2.67 ft2
ISOGARD HD Composite
Minimum 1-1/2” thick 1 with 9 (steel)
2 or 3 with 9 (concrete)
1:2.67 ft2
ISO 95+ GL
Minimum 2” thick 1 with 9 (steel)
2 or 3 with 9 (concrete)
1:2.67 ft2
Note: All Insulation shall be mechanically attached with fasteners and density described above. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board
shall be increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for
fastening details.
Base Sheet: One or more layers of APP Premium Base (over ISO 95+ GL only), APP 160 Cool, or APP
170 Cool fully adhered to the insulation with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Only when SECUROCK Gypsum-Fiber Roof Board or DensDeck Prime is used) One or
more layers of APP 80 Glass Base, APP Premium Base, APP 160, APP 160 P, APP 160
Cool, APP 170, or APP 170 Cool fully adhered by torch adhering with minimum 3” wide
side laps.
Or
One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, or MB Base fully adhered with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Only when SECUROCK Gypsum-Fiber Roof Board or DensDeck Prime is used) One or
more plies of SBS Glass Torch Base, SBS Poly Base Torch, or SBS Glass Torch Base 1.5
torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 50 of 68
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, SBS Premium
Base, SBS Poly Base, SBS Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot
asphalt only), or MB Base fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40
lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly Base
Torch, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
Membrane:
(Not for use with APP sheets) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap,
SBS FR Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite,
SBS Glass, SBS Glass FR, or SBS Glass FR UltraWhite fully adhered with Firestone Multi-
Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.., or hot asphalt applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 170 Cool, APP
180 Cool or APP 180 FR Cool fully adhered to the base sheet with Firestone Multi-Purpose
MB Cold Adhesive applied at 1½ - 2 gal./sq. with minimum 3” wide side laps.r
(Not for use over SBS sheets) One ply of Firestone APP 160, APP 160 P, APP 160 Cool,
APP 170, or APP 170 Cool, APP Premium FR, APP 180, APP 180 UltraWhite, APP 180
Cool, APP 180 FR, APP 180 FR UltraWhite or APP 180 FR Cool torch adhered with
minimum 3” wide side laps.
Maximum Design
Pressure:
-45 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 51 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 40 steel deck is secured to structural support at a maximum spacing
of 6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with 5/8”
puddle welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. The existing roof shall be
a minimum 1/2” thick. *The deck should record a Minimum Characteristic Resistance Force
(MCRF) of 320 lbf. when tested with Firestone All-Purpose or Firestone Heavy-Duty
fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(20): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gyspsum-Fiber Roof Board
Minimum ½” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete) 1:1.78 ft2
ISOGARD HD Composite
Minimum 1-1/2” thick 1 with 9 (steel deck)
2 or 3 with 9 (concrete) 1:1.78 ft2
Note: All Insulation shall be mechanically attached with fasteners and density described above. Insulation
panels listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board
shall be increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for
fastening details.
Base Sheet: One or more layers of APP 160 Cool, or APP 170 Cool fully adhered to the insulation with
Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. with
minimum 3” wide side laps.
Or
(Not for ISOGARD HD Composite) One or more layers of APP 80 Glass Base, APP
Premium Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully
adhered by torch adhering with minimum 3” wide side laps.
Or
One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only), or MB Base fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.
or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side
laps.
Or
(Not for ISOGARD HD Composite) One or more plies of SBS Glass Torch Base, SBS Poly
Base Torch, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 52 of 68
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, SBS Premium
Base, SBS Poly Base, SBS Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot
asphalt only), or MB Base fully adhered with Firestone Multi-Purpose MB Cold Adhesive
applied at a rate of 1.5-2.0 gal./sq. or LiquiGard Membrane Adhesive applied at a rate of 1.5-
2.0 gal./sq., or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum
3” wid e side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly Base
Torch, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
Membrane:
(Not for use with SBS) One ply of APP 180 FR Cool, APP 180 Cool or APP Premium FR
fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0
gal./sq. with minimum 3 in. wide side laps.
Or
(Not for use with SBS) One ply of APP 180, APP 180 UltraWhite, APP 180 FR, APP 180
FR UltraWhite, APP 180 Cool, APP 180 FR Cool, or APP Premium FR torch adhered with
minimum 3 in. wide side laps.
Or
(Not for use with APP) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR
Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS
Glass, SBS Glass FR, SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose
MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT
range at a rate of 20-25 lbs./sq. with minimum 3 in. wide side laps.
Or
(Not for use with APP) One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite,
SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite,
SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR
Torch UltraWhite torch adhered with minimum 3 in. wide side laps.
Maximum Design
Pressure: -90 psf. (See General Limitation #7)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 53 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 40 steel deck secured to structural supports at a maximum spacing
of 6 ft. o.c. or concrete deck. Steel deck is fastened to supports at every flute with 5/8”
puddle welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Charcteristic Resistance Force (MCRF) of 195 lbf. When tested with Firestone
All Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(21): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL
Minimum 2.5” thick
1 with 9 (steel)
2 or 3 with 9 (concrete)
1:1 ft2
Note: All Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more layers of APP Premium Base, APP 160 Cool, or APP 170 Cool fully adhered to
the insulation with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0
gal./sq. with minimum 3” wide side laps.
Or
One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, or MB Base fully adhered with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, SBS Premium
Base, SBS Poly Base, SBS Premium Poly Base, Ply IV, Ply VI, or MB Base fully adhered
with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot
asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly Torch
Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 54 of 68
Membrane:
(Not for use with APP sheets) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap,
SBS FR Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite,
SBS Glass, SBS Glass FR, or SBS Glass FR UltraWhite fully adhered with Firestone Multi-
Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180 Cool, APP
180 FR Cool fully adhered to the base sheet with Firestone Multi-Purpose MB Cold
Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180, APP 180
UltraWhite, APP 180 Cool, APP 180 FR, APP 180 FR UltraWhite or APP 180 FR Cool
torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-97.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 55 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural supports at a maximum spacing
of 6 ft. o.c. or concrete deck. Steel deck is fastened to supports at every flute with 5/8”
puddle welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Charcteristic Resistance Force (MCRF) of 224 lbf. When tested with Firestone
All Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(22): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL
Minimum 2.5” thick
1 with 9 (steel)
2 or 3 with 9 (concrete)
1:2.13 ft2
Note: All Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more layers of APP Premium Base, APP 160 Cool, or APP 170 Cool fully adhered to
the insulation with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0
gal./sq. with minimum 3” wide side laps.
Or
One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, or MB Base fully adhered with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, SBS Premium
Base, SBS Poly Base, SBS Premium Poly Base, Ply IV, Ply VI, or MB Base fully adhered
with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot
asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly Torch
Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 56 of 68
Membrane:
(Not for use with APP sheets) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap,
SBS FR Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite,
SBS Glass, SBS Glass FR, or SBS Glass FR UltraWhite fully adhered with Firestone Multi-
Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180 Cool or
APP 180 FR Cool fully adhered to the base sheet with Firestone Multi-Purpose MB Cold
Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180, APP 180
UltraWhite, APP 180 Cool, APP 180 FR, APP 180 FR UltraWhite or APP 180 FR Cool
torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 57 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural supports at a maximum spacing
of 6 ft. o.c. or concrete deck. Steel deck is fastened to supports at every flute with 5/8”
puddle welds. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Charcteristic Resistance Force (MCRF) of 256 lbf. When tested with Firestone
All Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(23): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RSISTA
Minimum 1” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum ½” thick 1 or 2 with 9 (steel)
2 or 3 with 9 (concrete)
1:2.13 ft2
ISOGARD HD Composite
Minimum 1.5” thick 1 or 2 with 9 (steel)
2 or 3 with 9 (concrete)
1:2.13 ft2
Note: Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more layers of APP 160 Cool, or APP 170 Cool fully adhered to the insulation with
Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. with
minimum 3” wide side laps.
Or
(Not for ISOGARD HD Composite) One or more layers of APP 80 Glass Base, APP
Premium Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully
adhered by torch adhering with minimum 3” wide side laps.
Or
One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV, Ply VI, or MB Base fully adhered with Firestone Multi-Purpose
MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT
range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
(Not for ISOGARD HD Composite) One or more plies of SBS Glass Torch Base, SBS Poly
Torch Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 58 of 68
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, SBS Premium
Base, SBS Poly Base, SBS Premium Poly Base, Ply IV, Ply VI, or MB Base fully adhered
with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot
asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly Torch
Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
Membrane: (Not for use with APP sheets) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap,
SBS FR Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite,
SBS Glass, SBS Glass FR, or SBS Glass FR UltraWhite fully adhered with Firestone Multi-
Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180 Cool or
APP 180 FR Cool fully adhered to the base sheet with Firestone Multi-Purpose MB Cold
Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180, APP 180
UltraWhite, APP 180 Cool, APP 180 FR, APP 180 FR UltraWhite or APP 180 FR Cool
torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-60 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 59 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural supports at a maximum spacing
of 6 ft. o.c. or concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-
1/4” HWH screws. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should
record a Minimum Characteristic Resistance Force (MCRF) of 240 lbf. When tested with
Firestone All Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type C(24): Membrane fully adhered over mechanically fastened insulation.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum ¼” thick 1 with 9 (steel)
2 or 3 with 9 (concrete)
1:1.78 ft2
Note: Insulation shall be mechanically attached with fasteners and density described above. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used the number of fasteners per board shall be
increased maintaining the same fastener density. See Roofing Application Standard RAS 117 for fastening
details.
Base Sheet: One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV, Ply VI, MB Base, fully adhered to the insulation with Firestone
Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in
the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, SBS Glass Torch Base 1.5
torch adhered with minimum 3” wide side laps.
Or
One or more layers of APP 160 Cool, or APP 170 Cool fully adhered to the insulation with
Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. with minimum
3” wide side laps.
Or
One or more layers of APP 80 Glass Base, APP Premium Base, APP 160, APP 160 P, APP
160 Cool, APP 170, or APP 170 Cool fully adhered by torch adhering with minimum 3” wide
side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 60 of 68
Ply Sheet (Optional): (Not for use with APP sheets) One or more plies of SBS Smooth, SBS Base, , SBS
Premium Base, SBS Poly Base, SBS Premium Poly Base, Ply IV (hot asphalt only), Ply VI
(hot asphalt only), or MB Base fully adhered with Firestone Multi-Purpose MB Cold
Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate
of 20-40 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One or more plies of SBS Glass Torch Base, SBS Poly Torch
Base, or SBS Glass Torch Base 1.5 torch adhered with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP Premium Base, APP 160 Cool,
APP 170 Cool fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a
rate of 1.5-2.0 gal./sq. with minimum 3” wide side laps.
Or
(Not for use with SBS sheets) One or more plies of APP 80 Glass Base, APP Premium
Base, APP 160, APP 160 P, APP 160 Cool, APP 170, or APP 170 Cool fully torch adhered
with minimum 3” wide side laps.
Membrane: (Not for use with APP sheets) One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap,
SBS FR Cap UltraWhite, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite,
SBS Glass, SBS Glass FR, or SBS Glass FR UltraWhite fully adhered with Firestone Multi-
Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Not for use with APP sheets) One ply of SBS Glass FR Torch, SBS Glass FR Torch
UltraWhite, SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch
UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS
Premium FR Torch UltraWhite torch adhered with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180 Cool or
APP 180 FR Cool fully adhered to the base sheet with Firestone Multi-Purpose MB Cold
Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
Or
(Not for use over SBS sheets) One ply of Firestone APP Premium FR, APP 180, APP 180
UltraWhite, APP 180 Cool, APP 180 FR, APP 180 FR UltraWhite or APP 180 FR Cool
torch adhered with minimum 3” wide side laps.
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-67.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 61 of 68
Membrane Type: APP/SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete
System Type D(1): All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1.5” thick N/A N/A
Note: Top layer of insulation shall have preliminary attachment, prior to the installation of the base/anchor
sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension
greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers of
insulation and base sheet shall be simultaneously fastened. See Roofing Application Standard RAS 117 for
fastening details. See base/anchor sheet below for fasteners and density.
Base Sheet: One ply of Firestone SBS Poly Base mechanically fastened to the deck through the insulation
with Firestone Heavy Duty fasteners and 2” Barbed Seam Metal Plates applied 12" o.c.
through the 4” wide base sheet overlaps.
Ply Sheet (Optional): One or more plies of SBS Smooth (hot asphalt only), SBS Base, SBS Premium Base, SBS
Poly Base, SBS Premium Poly Base (hot asphalt only), Ply IV (hot asphalt only), Ply VI (hot
asphalt only, MB Base (hot asphalt only), fully adhered with Firestone Multi-Purpose MB
Cold Adhesive applied at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a
rate of 20-40 lbs./sq. with minimum 3” wide side laps.
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or
SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive
(Only over SBS Base, SBS Poly Base, SBS Smooth, or SBS Premium Base) applied at a
rate of 1.5-2.0 gal./sq. or hot asphalt (over MB Base, SBS Base, SBS Poly Base, SBS
Premium Base, SBS Premium Poly Base, Ply IV, Ply VI, or SBS Smooth) applied in the
EVT range at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(Only over SBS Base, SBS Poly Base or SBS Premium Base) One ply of Firestone APP 170
Cool, APP 180 Cool or APP 180 FR Cool fully adhered to the base sheet with Firestone
Multi-Purpose MB Cold Adhesive applied at 1.5 - 2 gal./sq. with minimum 3” wide side laps.
Surfacing (Optional): *Requird over SBS Smooth, APP 160, APP 160 P, APP 170, APP 180-P, APP 180 FR
Cool, APP 160 Cool, APP 170 Cool, or APP 180 Cool.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Gravel or slag at 400 lb. and 300 lb., respectively, set in a flood coat of type III or IV
asphalt at 60 lb./sq.
2. Karnak No. 97, No. 97 AF or No. 169 at an application rate of 1½-3 gal./sq..
Maximum Design
Pressure:
-45 psf. (See General Limitation #9.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 62 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Concrete
System Type D(2): All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1.5” thick N/A N/A
Note: Top layer of insulation shall have preliminary attachment, prior to the installation of the base/anchor
sheet, at a minimum application rate of two fasteners per board for insulation boards having no dimension
greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. All layers
of insulation and base sheet shall be simultaneously fastened. See Roofing Application Standard RAS 117 for
fastening details. See base/anchor sheet below for fasteners and density.
Base Sheet: One ply of Firestone SBS Poly Torch Base Sheet with a 4" side lap mechanically fastened
through the insulation to the deck with Firestone Heavy-Duty fasteners or Concrete Drive
Fastener and Insulation Fastening Plates at a spacing of 12" o.c. within the 4" side lap and two
staggered rows, equally spaced in the center of the sheet, 12" o.c.
Ply Sheet: One ply of Firestone SBS Poly Torch Base, SBS Glass Torch Base, SBS Glass Torch Base 1.5
or SBS Premium Poly Base, torch applied to the base sheet with the 3” side laps are heat fused
with a torch.
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, or
SBS Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive
(only over SBS Base, SBS Poly Base, SBS Smooth, or Premium Base) applied at a rate of
1.5-2.0 gal./sq. or hot asphalt (over MB Base, SBS Base, SBS Poly Base, SBS Premium
Base, SBS Premium Poly Base, Ply IV, Ply VI, or SBS Smooth) applied in the EVT range
at a rate of 20-25 lbs./sq. with minimum 3” wide side laps.
Or
(over SBS Glass Torch Base, SBS Glass Torch Base 1.5, SBS Premium Poly Base, or SBS
Poly Torch Base only) One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite,
SBS Torch, SBS Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite,
SBS FR Torch, SBS FR Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch
UltraWhite torch adhered with minimum 3” wide side laps.
Surfacing (Optional): Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Roof gravel at 400 lb./sq. in a flood coat of approved asphalt.
2. Roof gravel in Multi-Purpose MB Cold Adhesive at 2.5 gal./sq.
Maximum Design
Pressure:
-82.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 63 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural support at a maximum spacing of
6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-1/4”
HWH screws. Laps stitched 12” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Characteristic Resistance Force (MCRF) of 478 lbf. when tested with Firestone
Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table.
System Type D(3): All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA,
Minimum 1.5” thick N/A N/A
Note: Insulation shall be loose-laid and membrane mechanically fastened. See base sheet attachment below for
fasteners and density. Refer to Roofing Application Standard RAS 117 for insulation attachment requirements.
Base Sheet: One ply of SBS Poly Base, SBS Premium Poly Base, or SBS Smooth, mechanically fastened
through the insulation with Heavy-Duty fasteners and Coiled Metal Batten Strip spaced 18"
o.c. at the minimum 3" side laps.
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV (hot asphalt only), Ply VI (hot asphalt only), MB Base, fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.
or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side
laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, SBS Glass Torch Base 1.5
torch adhered with minimum 3” wide side laps.
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, SBS
Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied
at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq.
with minimum 3” wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 64 of 68
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-52.5 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 65 of 68
Membrane Type: SBS
Deck Type 7I: Recover, Insulated
Deck Description: Minimum 22 ga., Grade 33 steel deck secured to structural support at a maximum spacing of
6 ft. o.c. or Concrete deck. Steel deck is fastened to supports at every flute with #12 x 1-1/4”
HWH screws. Laps stitched 24” o.c. with #1/4x7/8” HWH screws. *The deck should record
a Minimum Characteristic Resistance Force (MCRF) of 120 lbf. when tested with Firestone
All-Purpose or Firestone Heavy-Duty fasteners in accordance with TAS 105.
This Tested Assembly has been analyzed for allowable deck stress. See Evidence
Submitted Table
System Type D(4): All layers of insulation and base sheet simultaneously attached.
All General and System Limitations apply.
One or more layers of any of the following insulations:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum ½” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ISO 95+ GL, RESISTA
Minimum 1” thick N/A N/A
Note: Insulation shall be loose-laid and membrane mechanically fastened. See base sheet attachment below for
fasteners and density. Refer to Roofing Application Standard RAS 117 for insulation attachment requirements.
Base Sheet: One ply of SBS Base, SBS Glass Torch Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, SBS Smooth or SBS Poly Torch Base, mechanically fastened through
the insulation with All-Purpose Fasteners (Steel deck only), Firestone Heavy-Duty, or
Concrete Drive Fasteners (Concrete only) and Insulation Fastening Plates spaced 12" o.c. at
the minimum 3.4" side laps and 12” o.c. in two staggered rows in the field of the roll.
Ply Sheet (Optional): One or more plies of SBS Smooth, SBS Base, SBS Premium Base, SBS Poly Base, SBS
Premium Poly Base, Ply IV (hot asphalt only), Ply VI, or (hot asphalt only) MB Base, fully
adhered with Firestone Multi-Purpose MB Cold Adhesive applied at a rate of 1.5-2.0 gal./sq.
or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq. with minimum 3” wide side
laps.
Or
One or more plies of SBS Glass Torch Base, SBS Poly Torch Base, SBS Glass Torch Base
1.5 torch adhered with minimum 3” wide side laps.
Membrane: One ply of SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS
Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR, SBS
Glass FR UltraWhite fully adhered with Firestone Multi-Purpose MB Cold Adhesive applied
at a rate of 1.5-2.0 gal./sq. or hot asphalt applied in the EVT range at a rate of 20-40 lbs./sq.
with minimum 3” wide side laps.
Or
One ply of SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Torch, SBS Torch
UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS FR Torch, SBS FR
Torch UltraWhite, SBS Premium FR Torch, SBS Premium FR Torch UltraWhite torch
adhered with minimum 3” wide side laps.
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 66 of 68
Surfacing (Optional): *Required over APP 180-P, APP 180 Cool, APP 180 FR Cool, SBS Smooth.
Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following to obtain required fire classification.
1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved
asphalt at 60 lbs./sq.
2. Karnak No. 97, No. 97 AF or No. 169, or APOC #212 at an application rate of 1.5
gal./sq.
3. Roof gravel in Firestone Multi-Purpose MB Cold Adhesive at 2.5 gal./sq. (SBS roof
covers).
Maximum Design
Pressure:
-60 psf. (See General Limitation #7.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 67 of 68
Membrane Type: SBS
Deck Type 7: Recover, Non-Insulated
Deck Description: Concrete/ /wood/steel.
System Type E(1): Base sheet mechanically fastened.
All General and System Limitations apply.
Base Sheet: One ply of Firestone SBS Base with a 4" side lap mechanically fastened to the deck as
described below:
Fastening: Firestone All Purpose fasteners (Steel Deck only), Heavy-Duty Fasteners, or Concrete Drive
(Concrete Deck only) with Insulation fastening Plates at a 4" side lap 18" o.c. and two rows
staggered in the center of the sheet 36" o.c.; See System Limitation #5.
Ply Sheet (Optional) : One or more plies of SBS Smooth, SBS Base Sheet, or Firestone Ply IV , Ply VI ply sheet
adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of
20-40 lbs./sq.
Membrane: One ply of Firestone SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap
UltraWhite, SBS Smooth, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite,
SBS Glass, SBS Glass FR, SBS Glass FR UltraWhite, adhered in a full mopping of
approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.
Or
(Not with SBS Base, SBS Smooth) One ply of Firestone SBS Smooth, SBS Cap, SBS Cap
UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS Glass, SBS Glass FR, SBS Glass
FR UltraWhite, SBS Premium, SBS Premium FR or SBS Premium FR UltraWhite cap sheet
fully adhered to the base sheet with Multi-Purpose MB Cold Adhesive applied at 1½ - 2
gal./sq.
Surfacing (Optional): Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install
one of the following:
1. Gravel or slag at 400 lb. and 300 lb., respectively, set in a flood coat of type III or IV
asphalt at 60 lb./sq..
2. Karnak No. 97, No. 97 AF or No. 169 at an application rate of 1½-3 gal./sq..
Maximum Design
Pressure:
-45 psf. (See General Limitation #9.)
NOA No.: 20-0818.11
Expiration Date: 03/08/26
Approval Date: 03/04/21
Page 68 of 68
RECOVER SYSTEM LIMITATIONS:
1. All System Limitations and General Limitations shall apply. See specific deck type Notice of Acceptance for deck
type System Limitations.
2. All assemblies listed herein shall be installed in compliance with the applicable sections of FBC 1521. Uplift
performance of assemblies bonded to existing roofing system shall be verified per 1521.10. Uplift performance of
assemblies mechanically attached through existing roofing system shall be verified per 1521.11.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT
range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each
sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not
acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of
either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be
submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing
Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant. (When this limitation is specifically referred within this
NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE