Loading...
HomeMy WebLinkAboutAPPROVED AC Duct Drawing(1) (2)Job #: 1480 Performed by Chris Bateman for: Hernandez Residence 5802 Birch Dr Ft. Pierce, FL 34982 Air Calcs, LLC 7550 Hidden Hammock Ln Vero Beach, FL 32966 Phone: 772.800.8413 vickilynne@aircalcs.com Scale: 1 : 107 Page 1 Right-Suite® Universal 2021 21.0.06 RSU29066 2021-Apr-28 14:19:18 ... HVAC\5802 Birch Dr PSL Prop.rup N Level 1 Garage WIC Laundry Hall Master Bed Master Bath Foyer Bed 3 Bed 2 Bath Lin Hall 2 Living Room Pantry Kitchen 10 x 6 64 cfm 10 x 6 56 cfm 8 x 8 98 cfm 8 x 8 98 cfm 12 x 8 153 cfm 12 x 8 210 cfm H/W12 x 12 210 cfm 3'0"W x 5'2"H3'0"W x 5'2"H 3'0"W x 5'2"H 3'0"W x 1'3"H 3'0"W x 1'3"H 3'0"W x 1'3"H 3'0"W x 5'2"H 3'0"W x 5'2"H 3'0"W x 3'2"H 3'0"W x 3'2"H 8'0"W x 6'8"H 2'2"W x 4'2"H 3'0"W x 6'8"H 16 x 16 8 x 8 60 cfm 4 " 6 " 80 CFM 4" Duct 4"Exhaust Vent 120 CFM 6" Duct 6"Exhaust Vent 10 x 6 77 cfm 12 x 12 201 cfm 12 x 12 153 cfm 10 x 10 152 cfm 10 x 10 152 cfm 30 x 18 896 cfm 10 x 10 171 cfm 10 x 10 171 cfm 12 x 12 219 cfm 12 x 12 16 " 16 " 6 " 5 " 6 " 6 " 12 " 7 " 7 " 10 " 4 "5 " 5 " 5 " 7 " 5 " 8 " 10 " 12 " 12 " DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE (0.48 MM) SHEET STEEL, 1 INCH MINIMUM RIGID NONMETALLIC CLASS 0 OR CLASS 1 DUCT BOARD, OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE