HomeMy WebLinkAboutHealth Department Septic Permit Approved of APPLICATION #:AP1695410
STATE OF FLORIDA PERMIT #:56-SF-1941462 .
_ DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT- AND DISPOSAL SYSTEM
DOCUMENT #:FI 1663144
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:
FEE PAID:
RECEIPT #:
APPLICANT: Kennedy Gabriel
AGENT: Jason Harris(All About Septic Services, Inc/Jason&Elizabeth Harris)
PROPERTY ADDRESS: 2908 Avenue Q Fort Pierce, FL 34947
LOT: 18&W 1/2 of 19 BLOCK: 6
SUBDIVISION: Sunrise Park ID#: 2405-501-0130-000-7
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION SETBACKS
[ ] [01] TANK SIZE [1] 1090.00 [21 [ ] [271 SURFACE WATER FT
[ ] [02] TANK MATERIAL Polypropylene [ ] [281 DITCHES 15 FT
[ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS FT
[ ] [041 MULTI-CHAMBERED [ Y N ] [ ] [301 PUBLIC WELLS _ FT
[ ] [051 OUTLET FILTER Polylok PL-68 [. ] [311 IRRIGATION WEAS- FT
[ ] [061 LEGEND 1. 70-143-11DC4 2, [ ] [32] POTABLE WATER 23 FT
[ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 6.5 FT
[. ] [081 LEVEL [ ] [341 PROPERTY LINES 10 FT
[ ] [091 DEPTH TO LID [ ] [35] OTHER FT
DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM
[ ] [101 AREA [11 384.88 [21 SQFT [ ] [361 DRAINFIELD COVER
[ ] [111 DISTRIBUTION BOX HEADER ' X [ ] [37] SHOULDERS
[ ] [121 NUMBER OF DRAINLINES 1. 4.00 2. [ ] [381 SLOPES
[ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 07/14/2021
[ ] [141 DRAINL'INE SLOPE
[ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION
[ ] [16] ELEVATION [ ABOVE / BELOW ]BM 7.00 [ ] [40] UNOBSTRUCTED AREA
[ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF
[ ] [181 DOSING PUMPS [ ] [421 ALARMS
[ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT
[ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA
[ ] [211 AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN
FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING
[ ] [221 FILL AMOUNT [ ] [47] CONTRACTOR Jason Harris(All About Septi
[ ] [23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ] [241 EXCAVATION DEPTH ABANDONMENT
[ ] [25] AREA REPLACED [ ] [49] TANK PUMPED
[ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED S FILLED
Comments: Comments are on page 2.
1000,
CONSTRUCTION L APPROVED / St. Lucie CHD DATE: 07/05/2019
DISAPPROVED )' Enviro enall Speclalist I an J Ingram(ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED / DISAPPROVED ]: St. Lucie . CHD DATE: 07/14/2021
Environmental Specialist III
I rian J Ingram(ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used).
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1695410 EID1941462
I -
APPLICATION #:AP1695410
STATE OF FLORIDA PERMIT #:56-SF-1941462
DEPARTMENT OF HEALTH DOCUMENT #:FI 1663144
c Q; ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
"�y CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:
FEE PAID:
RECEIPT #:
Violation Number Comment
Comments
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons(2 per bedroom),for a total estimated flow of 300
gpd•
Construction inspection results pulled from original inspection on 7/5/2019.
New ST,filter,and 2x8+2x9 long TRENCH DF installed. No violations,system ok to cover. Contractor notified onsite. Needs final
inspection for potable water line setback, building foundation setback, filled system,gutters?, building area,site plan conformity,
and final site grading.
Final system approved. Building department emailed final approval.
0
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
P EH Database v 1.0.1 AP1695410 EID1941462
I '