Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETLL�S9DL C®NTI L CIE WORKS CODE COMPLIANCE ST LUCIE COUNTY ROO I�I G�P I�(�11 t H O SHEET RECe►WD Florida Building Code 7th Edition (2020) JUL 19 2021 Based on Section 1525 of the Florida Building Code - Building at h INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 1,2,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2A4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6.7- Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable): 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design. CalcuIations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 LUCIE WORKS Section A (General Information) Master Permit No. Process No. Contractors Name: ifcsr_ o `5 License # GGC. 13Z3 8_�'1 Job Address Z305 lravbrAgP_ 59A efLe, ttcels ROOF CATEGORY Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑ Asphaltic Shingles [[Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance Reroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) 300 Steep Sloped Roof Area (SF) NO& Total (SF) ,12�� Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. �a STT. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify, as "NA") System Manufacturer: &Se. -9 Product Approval No.: �L 1-7 d V `i —� I D Design Wind Pressures, From RAS 128 Or Calculations: Zone 1"" 'S one 1: _ • one 27 &ibne 3: �4d� Max. Design PressuL�, fro he specific r°°��uct approval systemT! � o ` W-'.. Deck: �q . Type: T� Gauge Thickness: Slope: I Anchor/Base Sheet & No. df Ply(s): I Am Anchor/Base Sheet Fastener/B ding Material: In ula ion Base Layer:' Base Insultation Size and Thickness: Ah Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: lV)tf" Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s):� Base Sheet Fastener/Bonding Material: AA Ply Sheet(s)' & No. of Ply(s): y2I i& Surfacing: Fastener �Spacing for Anchor/Base Sheet Attachment: Zone 1' . n " oc @ Lap, # Rows— ° 00 Zone 1z oc @ Lap, # Rows @ ° oc Zone 2: 14.'' oc @ Lap, # Rows A ® -or. Zone 3 01 oc @ Lap, # RowAje@ ° 00 Number of Fast ners Per Insulation Board Zone 1'• Mdone 1: Z�kZone 2:Aone 3:I V, Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination; Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc., Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. FT. 4� Parapet —� Height FT. a Mean Roof Height Ply Sheet Fastener/Bonding Material: A; Top Ply:BMM PANUNJ Top Ply Fastener/Banding Material: 1Vr.1 .t Section D (Steep Slope Roof Roof System Manufacturer: —�L Notice of Acceptance Number: Minimum Design Wind Press res, If Applicable (From RAS?127 or Calculations): Zone 1: .33.gone 2e :�V ` >Zone 2n:"y Zone 2r:�ZZone 3e: gfzone 3r: Roof Slope: )6_: 121 �Z; RidgTP �tion? Deck Type: r- Type Underlayment cDu_ens ain,k7 P50 3 J 4-49/1 Insulation: ° Fire Barrier: Fastener Type & Spacing: Adhesive Type: Type Cap Sheet: Mean eight: ' Root Covering: Type & Size Drip %+ " ` Edge: