HomeMy WebLinkAboutPROJECT INFORMATIONCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-21 14:32:42 Right-Suite® Universal 2021 21.0.07 RSU08101 Page 1 ...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N Job:Project Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information JOHNSON RESIDENCEFor:6003 BAMBOO DRIVE, FT. PIERCE, FL Notes: Design Information Fort Pierce, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F28 Design TD °F15Daily range M Relative humidity %50Moisture difference gr/lb61 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh18171 Structure Btuh17209 Ducts Btuh3296 Ducts Btuh4081Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0 (none) (none)Humidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh21468 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh20226 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh2255 Ducts Btuh1238Central vent (0 cfm) Btuh0 CoolingHeating (none)10581058Area (ft²) Equipment latent load Btuh3493 1408414084Volume (ft³)Air changes/hour 0.230.45 Equipment Total Load (Sen+Lat)Btuh23720 Equiv. AVF (cfm) 54106 Req. total capacity at 0.70 SHR ton2.4 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg.Trade GOODMAN Trade GOODMAN Model GPH1430H41D Cond GPH1430H41DAHRI ref 201615902 Coil AHRI ref 201615902Efficiency 8 HSPF Efficiency 12.0 EER, 14 SEER Heating input Sensible cooling Btuh19880Heating output Btuh @ 47°F27600 Latent cooling Btuh8520 Temperature rise °F27 Total cooling Btuh28400Actual air flow cfm947 Actual air flow cfm947 Air flow factor cfm/Btuh0.044 Air flow factor cfm/Btuh0.044Static pressure in H2O0.50 Static pressure in H2O0.50 Space thermostat Load sensible heat ratio 0.86Capacity balance point = 36 °F Backup:Input = 6 kW, Output = 21457 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-21 14:32:42Right-Suite® Universal 2021 21.0.07 RSU08101 Page 1...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name Entire House LIVING 2 Exposed wall 138.0 ft 65.0 ft 3 Room height 13.3 ft 18.0 heat/coolft 4 Room dimensions ft438.0x1.0 5 Room area 1058.0 ft²438.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 230 200 508 390 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 10 0 338 330 0 0 0 0 .DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 21 21 229 217 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 652 601 1531 1175 432 408 1040 798 11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 91.1291.12 51 0 1822 4670 24 0 853 2187 WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 414 390 994 763 414 390 994 763 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 37.8837.88 24 0 853 909 24 0 853 909 WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 604 552 1407 1080 324 292 743 570 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 91.1291.12 32 0 1120 2870 12 0 427 1093 DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 20 20 223 211 20 20 223 211 CC 16B-13md16B-13md 0.0700.070 --1.961.96 3.503.50 1058 1058 2074 3703 438 438 858 1533 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 1058 138 3821 0 438 65 1800 0 6 c) AED excursion 0 -525 Envelope loss/gain 14921 16319 7791 7540 12 a) Infiltration 3250 890 2002 548 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)18171 17209 9793 8088 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 18171 17209 9793 8088 15 Duct loads 18%24%3296 4081 18%24%1777 1918 Total room load 21468 21291 11569 10006 Air required (cfm)Air required (cfm)947 947 510 445 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-21 14:32:42Right-Suite® Universal 2021 21.0.07 RSU08101 Page 2...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name BATH BEDROOM 2 Exposed wall 0 ft 14.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft6.0x7.0 ft14.0x11.0 5 Room area 42.0 ft²154.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 0 0 0 0 0 0 0 0 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0 .DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 0 0 0 0 140 113 287 221 11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 91.1291.12 0 0 0 0 27 0 969 2483 WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 37.8837.88 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 91.1291.12 0 0 0 0 0 0 0 0 DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 CC 16B-13md16B-13md 0.0700.070 --1.961.96 3.503.50 42 42 82 147 154 154 302 539 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 42 0 0 0 154 14 388 0 6 c) AED excursion -9 58 Envelope loss/gain 82 138 1946 3301 12 a) Infiltration 0 0 240 66 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)82 138 2185 3366 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 82 138 2185 3366 15 Duct loads 18%24%15 33 18%24%396 798 Total room load 97 171 2582 4165 Air required (cfm)Air required (cfm)4 8 114 185 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Jun-21 14:32:42Right-Suite® Universal 2021 21.0.07 RSU08101 Page 3...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name LAUNDRY KITCHEN/DINING 2 Exposed wall 19.0 ft 40.0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft8.0x11.0 ft28.0x12.0 5 Room area 88.0 ft²336.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 110 101 256 197 120 99 252 194 .GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 10 0 338 330 0 0 0 0 .DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 21 21 229 217 .WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 80 80 204 157 0 0 0 0 11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 91.1291.12 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 0 0 0 0 0 0 0 0 GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 37.8837.88 0 0 0 0 0 0 0 0 WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 0 0 0 0 280 261 664 510 GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 91.1291.12 0 0 0 0 20 0 693 1777 DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0 CC 16B-13md16B-13md 0.0700.070 --1.961.96 3.503.50 88 88 172 308 336 336 659 1176 FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 88 19 526 0 336 40 1108 0 6 c) AED excursion -66 542 Envelope loss/gain 1496 926 3605 4415 12 a) Infiltration 325 89 684 187 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1821 1015 4289 4602 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 1821 1015 4289 4602 15 Duct loads 18%24%330 241 18%24%778 1091 Total room load 2152 1255 5067 5694 Air required (cfm)Air required (cfm)95 56 224 253 Bold/italic values have been manually overridden 2021-Jun-21 14:32:42 Right-Suite® Universal 2021 21.0.07 RSU08101 Page 1 ...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N Job:Duct System Summary Date:Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM Project Information JOHNSON RESIDENCEFor: 6003 BAMBOO DRIVE, FT. PIERCE, FL CoolingHeating External static pressure in H2O0.50in H2O0.50 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.50in H2O0.50 Supply / return available pressure 0.294 / 0.206 in H2O in H2O0.294 / 0.206 Lowest friction rate in/100ft0.172in/100ft0.172 Actual air flow cfm947cfm947 Total effective length (TEL) ft291 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st2125.036.6VlFx0x04.00.18284171cBATH st2125.036.2VlFx0x08.00.1821851144165cBEDROOM st2125.040.4VlFx0x06.00.1781271122847cKITCHEN/DINING st2125.037.8VlFx0x06.00.1811271122847cKITCHEN/DINING-A st2125.046.4VlFx0x04.00.17256952152hLAUNDRY st2125.041.9VlFx0x06.00.1761481703857hLIVING st2125.040.2VlFx0x06.00.1781481703856hLIVING-A st2125.043.0VlFx0x06.00.1751481703856hLIVING-B Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st2 Peak AVF 947 947 0.172 886 14.0 0x0 VinlFlx st1 st1 Peak AVF 947 947 0.172 886 14.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb1 0x 4580 490 90.5 0.227 623 12.0 x0 0 VlFx rt1 rb2 0x 4890 457 119.8 0.172 622 12.0 x0 0 VlFx rt1 Bold/italic values have been manually overridden 2021-Jun-21 14:32:42 Right-Suite® Universal 2021 21.0.07 RSU08101 Page 2 ...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 947 947 0.172 886 14.0 0x0 VinlFlx