Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutPROJECT INFORMATIONCalculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-21 14:32:42
Right-Suite® Universal 2021 21.0.07 RSU08101 Page 1
...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N
Job:Project Summary Date:Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM
Project Information
JOHNSON RESIDENCEFor:6003 BAMBOO DRIVE, FT. PIERCE, FL
Notes:
Design Information
Fort Pierce, FL, USWeather:
Winter Design Conditions Summer Design Conditions
Outside db °F42 Outside db °F90Inside db °F70 Inside db °F75
Design TD °F28 Design TD °F15Daily range M
Relative humidity %50Moisture difference gr/lb61
Heating Summary Sensible Cooling Equipment Load Sizing
Structure Btuh18171 Structure Btuh17209
Ducts Btuh3296 Ducts Btuh4081Central vent (0 cfm) Btuh0 Central vent (0 cfm) Btuh0
(none) (none)Humidification Btuh0 Blower Btuh0
Piping Btuh0Equipment load Btuh21468 Use manufacturer's data n
Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh20226
Method Latent Cooling Equipment Load SizingSimplified
Construction quality Average0Fireplaces Structure Btuh2255
Ducts Btuh1238Central vent (0 cfm) Btuh0
CoolingHeating (none)10581058Area (ft²) Equipment latent load Btuh3493
1408414084Volume (ft³)Air changes/hour 0.230.45 Equipment Total Load (Sen+Lat)Btuh23720
Equiv. AVF (cfm) 54106 Req. total capacity at 0.70 SHR ton2.4
Heating Equipment Summary Cooling Equipment Summary
Make Goodman Mfg. Make Goodman Mfg.Trade GOODMAN Trade GOODMAN
Model GPH1430H41D Cond GPH1430H41DAHRI ref 201615902 Coil
AHRI ref 201615902Efficiency 8 HSPF Efficiency 12.0 EER, 14 SEER
Heating input Sensible cooling Btuh19880Heating output Btuh @ 47°F27600 Latent cooling Btuh8520
Temperature rise °F27 Total cooling Btuh28400Actual air flow cfm947 Actual air flow cfm947
Air flow factor cfm/Btuh0.044 Air flow factor cfm/Btuh0.044Static pressure in H2O0.50 Static pressure in H2O0.50
Space thermostat Load sensible heat ratio 0.86Capacity balance point = 36 °F
Backup:Input = 6 kW, Output = 21457 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-21 14:32:42Right-Suite® Universal 2021 21.0.07 RSU08101 Page 1...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N
Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC.
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM
1 Room name Entire House LIVING
2 Exposed wall 138.0 ft 65.0 ft
3 Room height 13.3 ft 18.0 heat/coolft
4 Room dimensions ft438.0x1.0
5 Room area 1058.0 ft²438.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 230 200 508 390 0 0 0 0
.GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 10 0 338 330 0 0 0 0
.DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 21 21 229 217 0 0 0 0
.WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 652 601 1531 1175 432 408 1040 798
11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 91.1291.12 51 0 1822 4670 24 0 853 2187
WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 414 390 994 763 414 390 994 763
GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 37.8837.88 24 0 853 909 24 0 853 909
WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 604 552 1407 1080 324 292 743 570
GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 91.1291.12 32 0 1120 2870 12 0 427 1093
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 20 20 223 211 20 20 223 211
CC 16B-13md16B-13md 0.0700.070 --1.961.96 3.503.50 1058 1058 2074 3703 438 438 858 1533
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 1058 138 3821 0 438 65 1800 0
6 c) AED excursion 0 -525
Envelope loss/gain 14921 16319 7791 7540
12 a) Infiltration 3250 890 2002 548
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)18171 17209 9793 8088
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 18171 17209 9793 8088
15 Duct loads 18%24%3296 4081 18%24%1777 1918
Total room load 21468 21291 11569 10006
Air required (cfm)Air required (cfm)947 947 510 445
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-21 14:32:42Right-Suite® Universal 2021 21.0.07 RSU08101 Page 2...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N
Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC.
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM
1 Room name BATH BEDROOM
2 Exposed wall 0 ft 14.0 ft
3 Room height 10.0 heat/coolft 10.0 heat/coolft
4 Room dimensions ft6.0x7.0 ft14.0x11.0
5 Room area 42.0 ft²154.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 0 0 0 0 0 0 0 0
.GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 0 0 0 0 0 0 0 0
.DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
.WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 0 0 0 0 140 113 287 221
11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 91.1291.12 0 0 0 0 27 0 969 2483
WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 0 0 0 0 0 0 0 0
GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 37.8837.88 0 0 0 0 0 0 0 0
WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 0 0 0 0 0 0 0 0
GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 91.1291.12 0 0 0 0 0 0 0 0
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16B-13md16B-13md 0.0700.070 --1.961.96 3.503.50 42 42 82 147 154 154 302 539
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 42 0 0 0 154 14 388 0
6 c) AED excursion -9 58
Envelope loss/gain 82 138 1946 3301
12 a) Infiltration 0 0 240 66
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)82 138 2185 3366
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 82 138 2185 3366
15 Duct loads 18%24%15 33 18%24%396 798
Total room load 97 171 2582 4165
Air required (cfm)Air required (cfm)4 8 114 185
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2021-Jun-21 14:32:42Right-Suite® Universal 2021 21.0.07 RSU08101 Page 3...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N
Job:Right-J® Worksheet Date:Entire House By:QUICK CALCS, INC.
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM
1 Room name LAUNDRY KITCHEN/DINING
2 Exposed wall 19.0 ft 40.0 ft
3 Room height 10.0 heat/coolft 10.0 heat/coolft
4 Room dimensions ft8.0x11.0 ft28.0x12.0
5 Room area 88.0 ft²336.0 ft²
Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load
number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 WW 12C-0sw12C-0sw 0.0910.091 nn 2.552.55 1.961.96 110 101 256 197 120 99 252 194
.GG 1A-c1om1A-c1om 1.2701.270 nn 35.5635.56 34.7734.77 10 0 338 330 0 0 0 0
.DD 11D011D0 0.3900.390 nn 10.9210.92 10.3410.34 0 0 0 0 21 21 229 217
.WW 12C-0sw12C-0sw 0.0910.091 ee 2.552.55 1.961.96 80 80 204 157 0 0 0 0
11 GG 1A-c1om1A-c1om 1.2701.270 ee 35.5635.56 91.1291.12 0 0 0 0 0 0 0 0
WW 12C-0sw12C-0sw 0.0910.091 ss 2.552.55 1.961.96 0 0 0 0 0 0 0 0
GG 1A-c1om1A-c1om 1.2701.270 ss 35.5635.56 37.8837.88 0 0 0 0 0 0 0 0
WW 12C-0sw12C-0sw 0.0910.091 ww 2.552.55 1.961.96 0 0 0 0 280 261 664 510
GG 1A-c1om1A-c1om 1.2701.270 ww 35.5635.56 91.1291.12 0 0 0 0 20 0 693 1777
DD 11D011D0 0.3900.390 ww 10.9210.92 10.3410.34 0 0 0 0 0 0 0 0
CC 16B-13md16B-13md 0.0700.070 --1.961.96 3.503.50 88 88 172 308 336 336 659 1176
FF 22A-tpl22A-tpl 0.9890.989 --27.6927.69 0.000.00 88 19 526 0 336 40 1108 0
6 c) AED excursion -66 542
Envelope loss/gain 1496 926 3605 4415
12 a) Infiltration 325 89 684 187
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230230 0 0 0 0
Appliances/other 0 0
Subtotal (lines 6 to 13)1821 1015 4289 4602
Less external loadLess external load 0 0 0 0
Less transferLess transfer 0 0 0 0
RedistributionRedistribution 0 0 0 0
14 Subtotal 1821 1015 4289 4602
15 Duct loads 18%24%330 241 18%24%778 1091
Total room load 2152 1255 5067 5694
Air required (cfm)Air required (cfm)95 56 224 253
Bold/italic values have been manually overridden
2021-Jun-21 14:32:42
Right-Suite® Universal 2021 21.0.07 RSU08101 Page 1
...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N
Job:Duct System Summary Date:Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LANE, FT. PIERCE, FL 34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM
Project Information
JOHNSON RESIDENCEFor:
6003 BAMBOO DRIVE, FT. PIERCE, FL
CoolingHeating
External static pressure in H2O0.50in H2O0.50
Pressure losses in H2O0in H2O0
Available static pressure in H2O0.50in H2O0.50
Supply / return available pressure 0.294 / 0.206 in H2O in H2O0.294 / 0.206
Lowest friction rate in/100ft0.172in/100ft0.172
Actual air flow cfm947cfm947
Total effective length (TEL) ft291
Supply Branch Detail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv
Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk
st2125.036.6VlFx0x04.00.18284171cBATH
st2125.036.2VlFx0x08.00.1821851144165cBEDROOM
st2125.040.4VlFx0x06.00.1781271122847cKITCHEN/DINING
st2125.037.8VlFx0x06.00.1811271122847cKITCHEN/DINING-A
st2125.046.4VlFx0x04.00.17256952152hLAUNDRY
st2125.041.9VlFx0x06.00.1761481703857hLIVING
st2125.040.2VlFx0x06.00.1781481703856hLIVING-A
st2125.043.0VlFx0x06.00.1751481703856hLIVING-B
Supply Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk
st2 Peak AVF 947 947 0.172 886 14.0 0x0 VinlFlx st1
st1 Peak AVF 947 947 0.172 886 14.0 0x0 VinlFlx
Return Branch Detail Table
Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk
rb1 0x 4580 490 90.5 0.227 623 12.0 x0 0 VlFx rt1
rb2 0x 4890 457 119.8 0.172 622 12.0 x0 0 VlFx rt1
Bold/italic values have been manually overridden
2021-Jun-21 14:32:42
Right-Suite® Universal 2021 21.0.07 RSU08101 Page 2
...ts\Wrightsoft HVAC\JOHNSON RESIDENCE-LAYOUT.rup Calc = MJ8 Front Door faces: N
Return Trunk Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk
rt1 Peak AVF 947 947 0.172 886 14.0 0x0 VinlFlx